BLD2023-1385_Other_11.1.2023_11.16.41_AM_3874214FJM Base Series Fan Coil Sizes 18 - 60 Product Data A200369 AIR HANDLER TECHNOLOGY AT ITS FINEST The FJM fan coil has the proven technology of ICP fan coil units with R-410A refrigerant as well as vertical and horizontal applications. The design features contoured condensate pans with rugged drain connections, ensuring that little water is left in the unit at the end of the cooling duty cycle. The lack of standing condensate and corrosion free pans improves IAQ and product life, features homeowners appreciate. Standard features include grooved tubing and louvered fins. Coil circuiting has also been updated to make the most of all ICP heat pumps and air conditioners. Units come with solid state fan controls, 1-inch (25mm) thick insulation with R-value of 4.2, multi -speed motors, and fully -wettable coils. Units can accommodate factory- and/or field -installed heaters from 3 to 30 kW. Assembled at the factory compliant with low leak requirements of less than 2% cabinet leakage rate at 0.5 inches W.C. and 1.4% cabinet leakage rate at 0.5 inches W.C. when tested in accordance with ASHRAE 193 standard. The FJM fan coil design is loaded with popular features. These fan coils utilize the latest in electronic commutation motor (ECM) technology through the use of high efficiency, multi -tap ECM motors allowing reliable air delivery with increased static pressure. It comes in a pre -painted (taupe metallic) galvanized steel casing and a factory -supplied power plug for ease of installation. The unit is shipped with a R-410A refrigerant TXV (sizes 18-60). TEMPST�:I Heating and Cooling Products STANDARD FEATURES • Multi -tap ECM (electronic commutating motor) motors — all sizes • Integrated motor controls, with 90-sec off TDR function, have replaced integrated circuit board. • Five available speed tags to meet a wide range of applications • Large, grooved tube, louvered fin coils • Efficient, quiet, time -tested blower housings and diffusers • Sturdy, drainable condensate pans • Cabinet construction features innovations designed to prevent cabinet sweating. • Tested for condensate disposal in much tougher conditions than Air Conditioning and Refrigeration Institute requirements. • Super -thick R-4.2 insulation with vapor barrier • Pre -painted galvanized steel cabinet (taupe metallic) • Design meets stringent regulations for cabinet air leakage of less than 2% when tested at 0.5 inches W.C., and cabinet air leakage less than 1.4% at 0.5 inches W.C. when tested in accordance with ASHRAE 193 standard. • Installation -flexible, multipoise units • Horizontal hanging provisions on cabinet • No tools required to access filter. • Newly improved filter rack area filter door insulation added for improved air seal. • Factory -installed heater packages available on select models (5 through 15 kW). • 3 through 30 kW accessory heaters - field installed • Factory -supplied power plug • Easy plug-in provisions for heater installation. • Entry options for high and low voltage wiring hook-up. • Leak -preventing sweat connections • Thermostatic expansion valve, TXV, on all coils • Designed for manufactured housing applications. FJM: Product Data MODEL NUMBER NOMENCLATURE 1 2 3 F J M 4 5 6 7 8 9 10 11 12 A 4 X 1 8 L 0 B B —F Series Code Capacity 18 = 18,000 24 = 24,000 30 = 30,000 36 = 36,000 42 = 42,000 48 = 48,000 60 = 60,000 Cabinet Width A = 14" B=17" C= 21" D= 24" Coil Type L = Aluminum Em (1� Use of the AHRI Certified v TM Mark indicates a manufacturer's ' participation in the ISO 9001 program For verification pMl-$AI Global of certification for individual products, go to www.ahridirectory.org. A200437 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2 1111�,1=1ki61Eel kiK 7/8", 1 3/32" 2" DIA. K. O.'S FOR HIGH VOLTAGE POWER WIRING 7/8"DIA. K.O. 1 7/8" FOR LOW VOLTAGE CONTROL WIRING 1 15/16" 1" �1 3/8" TOP VIEW NOTE: Ew SERIES ELECTRICAL CHA R ACTE R ST ICS A B C D E F G J CONFIGURATION SHIPPING WT (LBS) SLOPE "A" FJMA4X18 01 X 0 42 11/16" 14 5/16" 12 7/16" 12 5/16" 10 7/16" 18 1/8" 18 5/8" 12" X - - FJMA4X24 01 X 0 49 5/8" 17 5/8" 15 3/4" 15 5/8" 15 3/8" 23 1/8" 23 5/8" 11" X - - FJMA4X30 01 X 0 49 5/8" 17 5/8" 15 3/4" 15 5/8" 15 7/8" 23 1/8" 23 1/2" - - X - FJMA4X36 01 X 0 49 5/8" 17 5/8" 15 3/4" 15 5/8" 15 7/8" 23 1/8" 23 1/2" - - X - FJMA4X42 01 X 49 5/8" 21 1/8" 19 1/4" 19 11V 15 11/16" 23 7/16" 23 1/8" - - X - FJMA4X48 01 X 53 7/16" 21 1/8" 19 114" 19 1/8" 19 112" 27 114" 26 15/16" - - X - FJMA4X60 01 X 59 3/16" 24 11/16" 1 22 3/4" 22 11/16" 25 1/4" 1 32 15/16" 32 5/8" 1 X - 0 0 X-YES O=NO *:YES, DUE TO AVAILABLE FIELD INSTALLED HEATERS. NOTE: ALLOW 21" FROM FRONT FOR SERVICE 22 1/16" 1. SERIES DESIGNATION IS THE 13TH 8 14TH POSITION OF UNIT PRODUCT NUMBER 10 3/16" 15/16" B C 2. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED. 2 8" 1/ 1" OUTLET AIR 3/4" DISCONNECT OR CIRCUIT BREAKER ° LOCATION UNIT CONNECTION SIZESALTERNATE 1/8",1 3/32",2"DIA. K.O. 'S LOWER, CONTROL, FOR HIGH VOLTAGE 8 ELECTRIC HEATER SUCTION: 18 THRU 24 - 5/8" I.D. SWEAT ALTERNATE POWER WIRING ACCESS PANEL 30 8 36 - 3/4" I.D. SWEAT 7/8ODIA. K.O. OPPOSITE SIDE 42 THRU 60 - 7/8" I.D. SWEAT FOR LOW VOLTAGE LIQUID : 3/8" I.D. SWEAT CONTROL WIRING CONDENSATE: 3/4" FPT OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING INLET AIR (SLOPE COIL UNITS ONLY) A OIL ACCESS 1 1/2" PANEL � 2 5/8" 4 11/16" ° ® LIQUID LINE E ° ® FITTING PANEL LIQUID LINE CONNECTION 3 1/16" CONNECTION Ll LIQUID LINE CONNECTION SUCTION LINE CONNECTION 1 3/16" MAX ® e SUCTION LINE ° � 9" 10 7/16" 10 3/4" ® CONNECTION e ® e ° g 9 1/2° O O O 1 3l8" ®6, ® ® O Lu o o o 5" FILTER ACCESS OPENING OPENING � PANEL SLOPE COIL DETAILS ACCESS PANEL CONFIG. FOR 1 1/4" 19 13/16" 2 z D SLOPE COILS RIGHT SIDE VIEW CONNECTION LOCATIONS SHOWN FOR UPFLOW OR HORI Z. DOWNFLOW OR HORIZ. INLET AIR LEFT APPLICATIONS RIGHT APPLICATIONS AND INLET AIR FRONT VIEW "A" COILS SHOWN WITH "A" COIL DETAILS CONNECTION DOWNFLOW APPLICATIONS LOCATIONS FOR UPFLOW OR HORIZ. APPLICATIONS Fig. 1— FJM - English (sheet 1) A221151A DIMENSIONS (cont.) NOTES: 1. CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. 2. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED. PRIMARY DRAI SECONDARY DRAIN- 112" TYP.+ 7/8" TYP'* HORIZ. LEFT 5 (AS SHIPPED) PRIMARY DRA SECONDARY DRAI TYP.* 1 1/4" 1 5/16" TYP.+� 1 5/8" 2 1/8" 2 3/ YP. (2 PLACES)* + HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP PANEL, AND BACK OF CABINET. IN CABINET BOTTOM. HOLES PROVIDED . 1 3 6 " DIA. HORIZONTAL HANG I NO HARDWARE TO BE FIELD SUPPLIED. � 112" TYP+ 7/8" TYP+ PRIMARY DRAI SECONDARY DRAIN 1 1/2" J 5 7/8" 1 3/16" 7 7/8" HORIZ. LEFT (AS SHIPPED) SECONDARY PRIMARY DRAI 1 13/16" TYP+ OA � '' 2 TYP. (2 PLACES )+ UPFLOW (AS SHIPPED) UPFLOW (AS SHIPPED) /16" TYP. 2 PLACES)* AIRFLOW rp 3/16" TYP. (2 PLACES)+ o PRIMARY DRAIN SECONDARY DRAIN 5/16" TYP.+ SECONDARY DRAIN O PRIMARY DRAIN I , 2 7/8" y 0 1 5/8" 1. I 17/16" TYP " TYP. . (2 PLACES I+ (4 PLACES)* j� 1 13/16" 1/2" 1 1/4" TYP.* �• 7/8" 2 1/8" DOWNFLOW TYP.+ __4� F TYP .+ (FIELD CONVERTED) HORIZ, RIGHT (FIELD CONVERTED) 6" TYP. PLACES) 1 /16" (4 PLACES)* DOWNFLOW (FIELD CONVERTED) A -COIL Fig. 2 — FJM- English (sheet 2) AIRFLOW r 2 3/16" TYP. DARY DRAIN 5/16' TT� TYP.3 I S1+ 1/8" 7 7/8" 1 13/i6" TYP. HORIZ, RIGHT IYP.+ (FIELD CONVERTED) A221152 DIMENSIONS (cont.) 2E 22.23, 27.78 50. 80 DIA. K.O.'S FOR HIGH VOLTAGE POWER WIRING 22. 23 DIA. K.O. 47,6 FOR LOW VOLTAGE CONTROL WIRING 49.2 1 25.4 TOP VIEW 34.9 NLET AIR FRONT VIEW SHOWN WITH "A" COIL DETAILS CONNECTION LOCATIONS FOR UPFLOW OR HORIZ. APPLICATIONS NECT OR T BREAKER ON VER, CONTROL, -ECTRIC HEATER =SS PANEL UNT SERIES ELECTRICAL CHA R ACT ERST ICS A B C D E F G J CONFI oennoN SHIPPING WT (K9S1 SLOPE "A" FJMA4X18 01 X 0 1084.3 363.6 315.9 312.8 265.1 460.4 473.1 304.8 X - - FJMA4X24 01 X 0 1260.5 447.7 400.0 396.9 390.5 587.4 600.1 431.8 X - - FJMA4X30 01 X 0 1260.5 447.7 400.0 396.9 403.2 587.4 596.9 - - X - FJMA4X36 01 X 0 1260.5 447.7 400.0 396.9 403.2 587.4 596.9 - - X - FJMA4X42 01 X + 1260.5 536.6 489.0 485.8 398.5 595.3 587.4 - - X - FJMA4X48 01 X 1 357. 3 536.6 489.0 485.8 495.3 692.2 684.2 - - X - FJMA4X60 01 X 1 503. 4 627.1 577.8 576.3 641.4 836.6 828.7 - - X - 0 0 X-YES 0=NO --YES, DUE TO AVAILABLE FIELD INSTALLED HEATERS. NOTE: 1. SERIES DESIGNATION IS THE 13TH 8 14TH POSITION OF UNIT PRODUCT NUMBER 2. ALL DIMENSIONS ARE IN "MM" UNLESS NOTED. L ACCESS EL [D LINE CONNECTION ON LINE CONNECTION TER ACCESS EL UNIT CONNECTION SIZES SUCTION: 18 THRU 24 - 15.88 I.D. SWEAT 30 8 36 - 19.05 I.D. SWEAT 42 THRU 60 - 22.23 I.D. SWEAT LIQUID: 9.53 I.D. SWEAT CONDENSATE: 19.0 FPT 119.1 77.8 27I.0 241.3 LIQUID LINE CONNECTION SUCTION LINE CONNECTION NOTE: ALLOW 533.4 FROM FRONT FOR SERVICE 5 ALTERNATE 22.23 DIA. K.O. FOR LOW VOLTAGE CONTROL WIRING INLET AIR SLOPE COIL DETAILS ACCESS PANEL CONFIG. FOR CONNECTION LOCATIONS SHOWN SLOPE COILS FOR UPFLOW OR HORIZ. DOWNFLOW OR HORIZ. LEFT APPLICATIONS RIGHT APPLAND ICATIONS "A" COILS DOWNFLOW APPLICATIONS Fig. 3 - FJM - Metric (sheet 1) 560.4 258.8 OU279.4 - 22.2 4.0 25.4 TLET AIR 19.0 ALTERNATE 22.23, 27.78, 50.80 DIA. K.O.'S FOR HIGH VOLTAGE POWER WIRING OPPOSITE SIDE OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING (SLOPE COIL UNITS ONLY) 38.1 o 30.2 MAX 482.6 - 35.0 L - - - - - - o �O� 31.8 503.503.2 63.5 RIGHT SIDE VIEW 1_71� AIR A221153A 3 v v c m 'm (A m m to S m M. to Z. O cs S to SD DIMENSIONS (cont.) NOTES: 1. CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. 2. ALL DIMENSIONS ARE IN "MM" UNLESS NOTED, PRIMARY DRA SECONDARY DRAI PRIMARY DRAIN 46. SECONDARY DRAIN TYP0 .+ 31.8 1 8.6 TYP. 12.7 TYP. + 41.3 5 22.2 13.0 T,,. TYP + (2 PLACES)* HORIZ. LEFT 127.0 (AS SHIPPED) + HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP PANEL, AND BACK OF CABINET. IN CABINET BOTTOM. HOLES PROVIDED 3.45 DIA. HORIZONTAL ANCING HARDWARE TO BE FIELD SUPPLIED. �12.7 TYP+ 22.2 TYP+ PRIMARY DRAI SECONDARY DRAIN 38.1 149.2 30.2 200.0 HORIZ. LEFT (AS SHIPPED) SECONDARY PRIMARY DRAI 46.0 TYP+ J 8.0 1II TYP- TYP. (2 PLACES)+ UPFLOW (AS SHIPPED) UPFLOW (AS SHIPPED) SLOPE COIL 1.1 TYP. 2 PLACES)- AIRFLOW r 55.6 TYP. (2 PLACES)+ PRIMARY DRAI SECONDARY DRAIN 8.0 TYP.+ SECONDARY DRAIN PRIMARY DRAIN/y 73.0 �• I 25.4 TYP. 11.1 TYP. 1 (2 PLACES )+ (4 PLACES)* 46.0 DOWNFLOW TYP + (FIELD CONVERTED) 1 TYP. PLACES) " 4 TYP. (2 PLACES) MINIM 79.4 3 (4 PLACES)* DOWNFLOW (FIELD CONVERTED) A -COIL Fig. 4 - FJM - Metric (sheet 2) AIRFLOW r 55.6 TYP, r 8.0 TYP. I S1+ 149. 200 46.0 200.0 TYP. 0 41.3 2.7 • 54 a0 31.8 TYP.* 22.2 F TYP.4 HORIZ, RIGHT (FIELD CONVERTED) HORIZ. RIGHT IYP.' (FIELD CONVERTED) A221154 FJM: Product Data Table 1— PHYSICAL DATA NOMINAL COOLING DIMENSIONS — IN (mm) SHIPPING WEIGHT UNIT SIZE CAPACITY (Btuh) 18,000 LB (KG) 120 Height Width Depth 18 42-11/16 in. 14-5/16 in. 22-1116 in. (1084mm) (364mm) (560mm) (54.4) 24 24,000 49-5/8 in. 17-5/8 in. 22-1/16 in. 131 (1260mm) (448mm) (560mm) (59.4) 30 30,000 49-5/8 in. 17-5/8 in. 22-1/16 in. 148 (1260mm) (448mm) (560mm) (67.1) 36 36,000 49-5/8 in. 17-5/8 in. 22-1/16 in. 148 (1260mm) (448mm) (560mm) (67.1) 42 42,000 49-5/8 in. 21-1/8 in. 22-1/16 in. 166 (1260mm) (537mm) (560mm) (75.3) 48 48,000 53-7/16 in. 21-1/8 in. 22-1/16 in. 182 (1357mm) (537mm) (560mm) (82.5) 60 60,000 59-3/16 in. 24-11/16 in. 22-1/16 in. 210 (1503mm) (627mm) (560mm) (95.2) Table 2 — SPECIFICATIONS r SIZE 18 24 30 36 42 48 60 EVAPORATOR COIL Face Area (sq. ft) 2.23 2.97 3.96 4.45 5.93 7.42 Configuration Slope A Metering Device R-410AR-410A TXV FILTER SIZE (W x L) 13-in x 20-in (330.2 x 508 mm) 16-in x 20-in (406.4 x 508 mm) 20-in x 20-in (508 x 508 mm) 23-in x 20-in (584.2 x 508.0 mm) BLOWER ASSEMBLY Motor Type (ECM) Multi -tap ECM Motor HP 1/3 1/3 1/2 1/2 1/2 314 3/4 CFM 525 700 875 1050 1225 1400 1750 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. FJM: Product Data »:770]N►Yi1_1 ki[a]:8I7_A(_1 Table 3 — Airflow Performance (CFM) Wet Ton (Size) Blower Speed External Static (in. wc) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Tap 5 754 737 717 694 668 641 605 572 528 481 Tap 4 695 678 655 628 600 573 551 520 479 421 1-1/2 (18) Tap 3 695 678 655 628 600 573 551 520 479 421 Tap 2 643 620 591 557 534 506 477 439 408 378 Tap 1 487 448 428 394 358 325 281 NA NA NA Tap 5 1021 1003 964 925 876 838 797 761 726 689 Tap 4 936 907 873 805 779 732 696 661 626 591 2 (24) Tap 3 936 907 873 805 779 732 696 661 626 591 Tap 2 846 831 792 739 702 651 609 548 536 491 Tapl 746 697 629 567 521 477 446 389 364 326 Tap 5 1247 1215 1188 1154 1122 1083 1053 1017 971 915 Tap 4 1133 1114 1082 1044 1009 968 924 873 835 785 2-1/2 (30) Tap 3 1133 1114 1082 1044 1009 968 924 873 835 785 Tap 2 1040 997 961 929 883 828 782 725 708 667 Tap 1 896 862 805 740 689 648 1251 1168 597 NA NA NA Tap 5 1433 1404 1363 1256 1328 1282 1201 1145 1080 1095 1021 Tap 4 1304 1277 1230 1207 1122 1073 983 3 (36) Tap 3 1304 1277 1256 1230 1207 1168 1122 1080 1073 983 Tap 2 1183 1148 1124 1094 1051 1005 955 901 846 783 Tap 1 1020 995 958 921 881 840 791 735 693 649 Tap 5 1571 1551 1508 1473 1439 1407 1372 1317 1253 1189 Tap 4 1517 1493 1458 1425 1392 1358 1328 1295 1253 1193 3-1/2 (42) Tap 3 1517 1493 1458 1425 1392 1358 1328 1295 1253 1193 Tap 2 1369 1339 1299 1263 1226 1188 1155 1112 1068 1012 Tap 1260 1231 1172 1143 1077 1041 995 949 896 867 Tap 5 1896 1853 1821 1795 1760 1737 1702 1670 1665 1619 Tap 4 1711 1673 1643 1607 1570 1549 1509 1490 1446 1411 4 (48) Tap 3 1711 1673 1643 1607 1570 1549 1509 1490 1446 1411 Tap 2 1547 1504 1466 1416 1388 1369 1324 1290 1239 1200 Tap 1397 1347 1312 1269 1232 1172 1135 1086 1038 989 Tap 5 2109 2067 2043 1996 1967 1928 1899 1848 1812 1766 Tap 4 2109 2067 2043 1996 1967 1928 1899 1848 1812 1766 5 (60) Tap 3 2109 2067 2043 1996 1967 1928 1899 1848 1812 1766 Tap 2 1901 1868 1825 1785 1737 1710 1662 1620 1584 1521 Tap 1583 1557 1499 1451 1392 1358 1313 1259 1194 1138 NOTES: 1. Airflow based upon dry coil at 230V with factory -approved filter and electric heater (2 element heater sizes 018 through 036, 3 element heater sizes 042 through 060). 2. To avoid potential for condensate blowing out of drain pan prior to making drain trap: Return static pressure must be less than 0.40 in. we. Horizontal applications of 042 - 060 sizes must have supply static greater than 0.20 in. we. Airflow above 400 cfm/ton on 048-060 size could result in condensate blowing off coil or splashing out of drain pan. 3. At higher pextstats (above 0.6 in/wc), water blowoff is more likely to occur depending on the user's setup. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. FJM: Product Data PERFORMANCE DATA (cont.) Table 4 — Airflow Performance (CFM) Dry Ton (Size) Blower Speed External Static (in. wc) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Tap 5 762 741 721 698 672 656 635 577 547 509 Tap 4 695 679 655 628 600 580 559 534 505 452 1-1/2 (18) Tap 3 695 679 655 628 600 580 559 534 505 452 Tap 2 634 615 585 547 522 506 475 444 407 371 Tap 1 498 470 434 390 356 300 272 NA NA NA Tap 5 1046 1013 978 958 925 877 830 752 722 687 Tap 4 992 950 916 869 812 763 705 660 611 585 2 (24) Tap 3 992 950 916 869 812 763 705 660 611 585 Tap 2 900 862 814 769 709 644 594 548 507 451 Tap 762 723 651 1226 599 531 1169 471 428 385 1058 345 319 1014 969 Tap 5 1277 1244 1193 1122 1094 Tap 4 1179 1142 1114 1070 1039 998 937 915 867 825 2-1/2 (30) Tap 3 1179 1142 1114 1070 1039 998 937 915 867 825 Tap 2 1066 1030 997 960 916 863 795 746 703 674 Tap 1 923 878 832 784 723 658 616 563 NA NA Tap 5 1489 1463 1428 1388 1345 1305 1262 1213 1160 1093 Tap 4 1357 1337 1310 1283 1249 1212 1165 1114 1064 1014 3 (36) Tap 3 1357 1337 1310 1283 1249 1212 1165 1114 1064 1014 Tap 2 1211 1190 1162 1132 1100 1066 1016 959 905 838 Tap 1059 1038 1004 967 925 887 843 791 747 681 Tap 5 1647 1620 1583 1548 1505 1464 1424 1379 1319 1250 Tap 4 1569 1539 1506 1476 1442 1404 1370 1336 1299 1219 3-1/2 (42) Tap 3 1569 1539 1506 1476 1442 1404 1370 1336 1299 1219 Tap 2 1393 1355 1329 1288 1248 1223 1180 1138 1091 1037 Tap 1 1265 1234 1195 1154 1111 1062 1022 964 914 865 Tap 5 1956 1917 1887 1855 1831 1798 1763 1743 1707 1683 Tap 4 1773 1743 1704 1667 1634 1612 1571 1536 1500 1464 4 (48) Tap 3 1773 1743 1704 1667 1634 1612 1571 1536 1500 1464 Tap 2 1566 1524 1483 1451 1414 1376 1340 1303 1266 1217 Tap 1413 1373 1328 1283 1246 1204 1168 1120 1075 1012 Tap 5 2148 2123 2084 2048 2002 1974 1939 1891 1893 1812 Tap 4 2148 2123 2084 2048 2002 1974 1939 1891 1893 1812 5 (60) Tap 3 2148 2123 2084 2048 2002 1974 1939 1891 1893 1812 Tap 2 1955 1913 1868 1833 1796 1442 1757 1711 1654 1294 1632 1221 1570 1164 Tap 1646 1590 1527 1496 1373 1315 NOTES: LAirflow based upon dry coil at 230V with factory -approved filter and electric heater (2 element heater sizes 018 through 036, 3 element heater sizes 042 through 060). 2. To avoid potential for condensate blowing out of drain pan prior to making drain trap: Return static pressure must be less than 0.40 in. we. Horizontal applications of 042 - 060 sizes must have supply static greater than 0.20 in. we. Airflow above 400 cfm/ton on 048-060 size could result in condensate blowing off coil or splashing out of drain pan. 3. At higher pextstats (above 0.6 in/wc), water blowoff is more likely to occur depending on the user's setup. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. FJM: Product Data Table 5 - Gross Cooling Capacities INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR ff / °C) Unit Size AIR 35/2 40/4 45/7 50/10 55/13 CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF 72/22 42.80 20.80 0.00 38.40 18.70 0.00 33.50 16.50 0.01 27.90 14.10 0.02 21.70 11.70 0.02 525 67/19 34.90 21.40 0.03 30.40 19.20 0.03 25.30 16.80 0.03 19.80 14.50 0.03 13.90 12.10 0.04 62/17 27.70 21.90 0.03 23.20 19.60 0.03 18.50 17.30 0.04 14.90 14.90 0.13 12.20 12.20 0.28 72/22 46.90 22.80 0.00 42.10 20.50 0.00 36.70 18.10 0.02 30.60 15.60 0.03 23.80 13.00 0.03 18 600 67/19 38.30 23.70 0.04 33.40 21.20 0.04 27.80 18.70 0.04 21.60 16.10 0.04 15.20 13.40 0.05 62/17 30.40 24.30 0.04 25.40 21.80 0.04 20.30 19.30 0.06 16.50 16.50 0.15 13.60 13.60 0.30 72/22 50.60 24.60 0.00 45.40 22.20 0.02 39.60 19.70 0.03 33.00 17.00 0.04 25.60 14.10 0.04 675 67/19 41.40 25.70 0.05 36.10 23.10 0.05 30.10 20.40 0.05 23.40 17.60 0.05 16.50 14.80 0.06 62/17 32.90 26.60 0.05 27.50 23.90 0.05 22.10 21.10 0.07 18.10 18.10 0.17 14.90 14.90 0.32 72/22 54.40 26.40 0.00 49.20 24.00 0.00 43.30 21.40 0.01 36.40 18.50 0.02 28.60 15.50 0.03 700 67/19 44.80 27.70 0.03 39.30 25.00 0.03 33.00 22.10 0.03 26.00 19.10 0.03 18.50 16.10 0.04 62/17 35.80 28.60 0.03 30.20 25.80 0.03 24.30 22.90 0.04 19.70 19.70 0.13 16.30 16.30 0.28 72/22 59.10 28.70 0.00 53.50 26.20 0.01 47.00 23.40 0.02 39.70 20.30 0.03 31.20 31.20 0.04 24 800 67/19 48.70 30.40 0.04 42.90 27.60 0.04 36.10 24.50 0.04 28.30 21.20 0.04 20.20 17.90 0.05 62/17 39.10 31.60 0.04 33.00 28.60 0.05 26.60 25.40 0.06 21.90 21.90 0.16 18.10 18.10 0.30 72/22 63.20 30.80 0.00 57.20 28.20 0.02 50.40 25.20 0.04 42.60 22.00 0.04 33.50 18.60 0.05 900 67/19 52.30 32.80 0.05 46.10 29.90 0.05 38.90 26.70 0.05 30.50 23.20 0.05 21.80 19.60 0.06 62/17 42.10 34.50 0.05 35.60 31.30 0.06 28.80 27.90 0.07 24.00 24.00 0.18 19.80 19.80 0.32 72/22 71.60 34.70 0.00 64.40 31.30 0.00 56.30 27.70 0.00 47.20 23.80 0.02 36.80 19.70 0.02 875 67/19 58.70 36.00 0.02 51.30 32.30 0.03 42.90 28.40 0.03 33.60 24.40 0.03 23.70 20.30 0.04 62/17 46.70 36.80 0.03 39.20 33.00 0.03 31.20 29.10 0.04 25.00 25.00 0.12 20.60 20.60 0.27 72/22 78.30 38.00 0.00 70.50 34.40 0.00 61.60 30.50 0.02 51.70 26.30 0.03 40.30 21.90 0.03 30 1000 67/19 64.30 39.70 0.03 56.30 35.80 0.03 47.10 31.50 0.04 36.80 27.10 0.04 26.00 22.70 0.05 62/17 51.40 40.90 0.04 43.10 36.70 0.04 34.40 32.40 0.05 27.90 27.90 0.14 23.00 23.00 0.29 72/22 84.30 41.00 0.00 75.90 37.20 0.00 66.80 33.20 0.02 55.80 28.60 0.04 43.60 23.80 0.04 1125 67/19 69.40 43.10 0.04 60.80 38.90 0.04 51.00 34.50 0.05 39.80 29.70 0.05 28.10 24.90 0.06 62/17 55.60 44.80 0.05 46.70 40.30 0.05 37.30 35.60 0.06 30.60 30.60 0.16 25.20 25.20 0.31 72/22 64.89 33.39 0.00 58.38 30.18 0.00 51.08 26.68 0.02 42.84 22.99 0.03 33.40 19.04 0.03 1050 67/19 53.14 34.96 0.04 46.48 31.47 0.04 38.88 27.72 0.04 30.22 23.74 0.04 21.13 19.74 0.05 62/17 42.35 36.18 0.04 35.45 32.44 0.04 28.12 28.54 0.05 22.73 22.73 0.15 18.64 18.64 0.29 72/22 70.55 36.42 0.00 63.54 32.99 0.02 55.62 29.26 0.03 46.67 25.30 0.04 36.48 21.08 0.05 36 1200 67/19 57.90 38.43 0.05 50.70 34.71 0.05 42.55 30.74 0.05 33.13 26.44 0.05 23.14 22.04 0.06 62/17 46.31 40.09 0.05 38.86 36.09 0.05 31.02 31.87 0.07 25.31 25.31 0.17 20.78 20.78 0.31 72/22 75.52 39.17 0.00 68.14 35.55 0.03 59.70 31.64 0.04 50.12 27.45 0.05 39.26 23.00 0.06 1350 67/19 62.18 41.63 0.06 54.49 37.72 0.06 45.77 33.52 0.06 35.75 28.98 0.06 25.00 24.22 0.08 62/17 49.84 43.73 0.06 42.00 39.53 0.07 33.71 35.01 0.09 27.74 27.74 0.20 22.79 22.79 0.33 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10 FJM: Product Data Table 5 - Gross Cooling Capacities INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR ff / °C) Unit Size AIR 35/2 40/4 45/7 50/10 55/13 CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF 72/22 79.15 40.41 0.00 70.85 36.31 0.00 61.59 31.90 0.02 51.15 27.24 0.03 39.41 22.38 0.04 1225 67119 64.55 42.04 0.04 56.05 37.58 0.04 46.51 32.90 0.04 35.85 28.04 0.04 24.90 23.25 0.05 62/17 51.09 43.18 0.04 42.46 38.53 0.05 33.59 33.84 0.06 27.05 27.05 0.15 22.11 22.11 0.30 72/22 86.34 44.20 0.00 77.30 39.79 0.01 67.22 35.05 0.03 55.91 30.07 0.04 43.10 24.80 0.05 42 1400 67/19 70.55 46.30 0.05 61.37 41.55 0.05 50.95 36.50 0.05 39.20 31.18 0.06 27.27 25.94 0.07 62/17 56.04 47.92 0.06 46.63 42.89 0.06 36.98 37.71 0.08 30.12 30.12 0.18 24.63 24.62 0.32 72/22 92.81 47.68 0.00 83.15 42.98 0.03 72.31 37.96 0.05 60.17 32.67 0.06 46.45 27.07 0.06 1575 67/19 76.00 50.25 0.06 66.13 45.22 0.06 55.01 39.88 0.07 42.37 34.20 0.07 29.47 28.50 0.08 62/17 60.57 52.40 0.07 50.47 47.01 0.07 40.22 41.43 0.09 33.01 33.01 0.20 26.99 26.99 0.34 72/22 83.95 44.30 0.00 75.71 40.05 0.00 66.36 35.45 0.01 55.84 30.58 0.02 43.82 25.38 0.03 1400 67/19 68.80 46.22 0.03 60.32 41.61 0.03 50.67 36.70 0.03 39.64 31.45 0.03 27.80 26.12 0.04 62/17 54.96 47.71 0.03 46.12 42.77 0.03 36.69 37.67 0.04 29.32 29.32 0.13 24.10 24.10 0.28 72/22 91.53 48.40 0.00 82.59 43.90 0.00 72.47 38.97 0.02 61.02 33.73 0.03 48.01 28.16 0.04 48 1600 67/19 75.19 50.91 0.04 65.98 45.99 0.04 55.57 40.75 0.04 43.57 35.09 0.04 30.49 29.21 0.05 62/17 60.21 52.94 0.04 50.73 47.68 0.04 40.48 42.10 0.06 32.72 32.72 0.15 26.92 26.92 0.30 72/22 98.31 52.15 0.00 88.79 47.39 0.02 77.99 42.21 0.03 65.70 36.65 0.04 51.81 30.76 0.05 1800 67/19 80.94 55.25 0.05 71.10 50.06 0.05 59.93 44.50 0.05 47.14 38.52 0.05 32.96 32.14 0.06 62/17 64.96 57.83 0.05 54.92 52.30 0.05 44.06 46.35 0.07 35.97 35.97 0.17 29.59 29.59 0.31 72/22 118.17 60.42 0.00 106.56 54.57 0.00 93.41 48.24 0.02 78.64 41.59 0.02 62.13 34.63 0.03 1600 67/19 96.74 62.87 0.03 84.83 56.56 0.03 71.43 49.91 0.03 56.41 42.93 0.03 39.37 35.48 0.04 62/17 77.24 64.78 0.03 65.10 58.16 0.03 51.83 51.23 0.04 41.00 41.00 0.12 33.67 33.67 0.27 72/22 129.14 66.15 0.00 116.46 59.92 0.00 102.18 53.13 0.02 86.08 45.94 0.03 68.00 38.39 0.03 60 1750 67/19 105.94 69.36 0.04 92.95 62.59 0.04 78.33 55.41 0.04 61.93 47.86 0.04 43.49 39.82 0.05 62/17 84.76 71.94 0.04 71.53 64.80 0.04 57.37 57.38 0.05 45.94 45.94 0.14 37.65 37.65 0.29 72/22 139.03 71.41 0.00 125.46 64.82 0.01 110.15 57.64 0.03 92.83 49.99 0.04 73.33 41.92 0.04 2000 67119 114.27 75.38 0.05 100.34 68.21 0.05 84.61 60.58 0.05 66.92 52.51 0.05 47.25 43.94 0.06 62/17 91.59 78.67 0.05 77.41 71.08 0.05 62.32 63.11 0.07 50.60 50.60 0.16 41.54 41.54 0.31 CFM - Cubic Ft per Minute EWB - Entering Wet Bulb °F (°C) LWB -Leaving Wet Bulb °F (°C) TC -Gross Cooling Capacity 1000 Btuh SHC -Gross Sensible Capacity 1000 Btuh BF - Bypass Factor MBH - 1000 Btuh NOTES: 1. Contact manufacturer for cooling capacities at conditions other than shown in table. 2. Formulas: Leaving db = entering db -sensible heat can. 1.09 x CFM Leaving wb = wb corresponding to enthalpy of air leaving coil (hlwb) hlwb = hewb -total capaci (Btuh) 4.5 x CFM where hewb = enthalpy of air entering coil. Direct interpolation is permissible. Do not extrapolate. 3. SHC is based on 80°F (27°C) db temperature of air entering coil. Below 80OF (27°C) db, subtract (Correction Factor x CFM) from SHC. Above 80°F (27°C) db, add (Correction Factor x CFM) to SHC. 4. Bypass Factor = 0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation. SHC CORRECTION FACTOR ENTERING AIR DRY-BULB TEMPERATURE (°F) 79 78 77 76 75 Under 75 BYPASS 81 82 83 84 85 Over 85 FACTOR ENTERING AIR DRY-BULB TEMPERATURE (°C) 26 25 25 24 24 Under 75 27 28 28 29 29 Over 85 Correction Factor 0.10 .098 1.96 2.94 3.92 4.91 Use 0.20 0.87 1.74 2.62 3.49 4.36 formula 0.30 T 0.76 1.53 2.29 3.05 3.82 shown below Interpolation is permissible. Correction Factor = 1.09 x (1 - BF) x (db - 80) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 11 FJM: Product Data PERFORMANCE DATA (cont.) Table 6 - Electric Heater Static Pressure Drop (in we) SIZES 18-36 SIZES 42-60 HEATER ELEMENTS 0 kW EXTERNAL STATIC PRESSURE CORRECTION HEATER ELEMENTS 0 kW EXTERNAL STATIC PRESSURE CORRECTION 0 +.02 0 +.04 1 3,5 +.01 1 3,5 +.03 2 8,10 0 2 8,10 +.02 3 9,15 -.02 3 9,15 0 4 20 -.04 4 20 -.02 6 18, 24, 30 -.10 The airflow performance data was developed using fan coils with 10-kW electric heaters (2 elements) in the 018 through 036 size units and 15-kW heaters (3 elements) in the 042 through 061 size units. For fan coils with heaters of a different number of elements, the external available static at a given CFM from the curve may be corrected by adding or subtracting available external static pressure as indicated above. Table 7 - Minimum CFM and Motor Speed Selection SIZE HEATER kW 3 5 8 9 10 15 18 20 24 30 18 525 525 525 - 600 - - - - - 24 700 700 700 - 700 775 - - - - 30 - 875 875 - 875 875 - 1060 - - 36 - 1050 970 970 970 920 - 1040 - - 42 - - 1225 1225 1225 1225 1225 1225 - - 48 - - 1400 1400 1400 1400 1400 1400 1400 1400 60 - - 1750 1750 1750 1750 1750 1750 1750 1750 Speed Tap 4 (white wire) is used for electric heat only. White wire must remain on tap 4. Table 8 - Estimated Sound Power Level (dBA)* CONDITIONS OCTAVE BAND CENTER FREQUENCY SIZE CFM Ext Static Pressure 63 125 250 500 1000 2000 4000 18 525 0.50 70.8 66.8 62.8 59.8 57.8 55.8 51.8 24 700 0.50 72.0 68.0 64.0 61.0 59.0 57.0 53.0 30 875 0.50 73.0 69.0 65.0 62.0 60.0 58.0 54.0 36 1050 0.50 73.8 69.8 65.8 62.8 60.8 58.8 54.8 42 1225 0.50 74.4 70.4 66.4 63.4 61.4 59.4 55.4 48 1400 0.50 75.0 71.0 67.0 64.0 62.0 60.0 56.0 60 1750 0.50 76.0 72.0 68.0 65.0 63.0 61.0 57.0 * Estimated sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications Handbook, Chapter 52, p. 52.7. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 12 FJM: Product Data PERFORMANCE DATA (cont.) Table 9 — EH Heater Table HEATER PART NO. kW @ 240V VOLTS/PH STAGES (kW OPERATING) INTERNAL CIRCUIT PROTECTION FAN COIL SIZE USED WITH HEATING CAP.* @ 230V EHC05CKN 5 230/1 5 None 18 15,700 EHC07CKN 8 230/1 8 None 18 25,100 EHC10CKN 10 230/1 10 None 18 31,400 EHC05BKN 5 230/1 5 None 24-60 15,700 EHC07BKN 8 230/1 8 None 24-60 25,100 EHC10BKN 10 230/1 10 None 24-60 31,400 EHC20BKF 20 230/1 5,20 Fusel 30-60 62,800 EHC05CKB 5 230/1 5 Circuit Breaker 18 15,700 EHC07CKB 8 230/1 8 Circuit Breaker 18 25,100 EHC10CKB 10 230/1 10 Circuit Breaker 18 31,400 EHC05BKB 5 230/1 5 Circuit Breaker 24-60 15,700 EHC07BKB 8 230/1 8 Circuit Breaker 24-60 25,100 EHC10BKB 10 230/1 10 Circuit Breaker 24-60 31,400 EHC20BKB 20 230/1 5,20 Circuit Breaker 30-60 62,800 EHC09BKCN 9 230/1t 3,9 None 36-60 28,200 EHC15BKF 15 230/1 5,15 Fusel 24-60 47,100 EHC15BKB 15 230/1 5,15 Circuit Breaker 24-60 47,100 3 Phase Only EHC15BHN 15 230/3 5,15 None 36-60 47,100 EHC18BHN 18 230/3 6, 12, 18 None 42-60 56,500 3 Phase, Factory Shipped (field convertible to single phase) EHC25BHCF 24 230/3 8, 16, 24 Fuse 48,60 78,300 EHC30BHCF 30 230/3 10, 20, 30 Fuse 48,60 94,100 *. Does not include heat from blower motor. 1. Single point wiring kit required for these heaters. $. Field convertible to 3 phase. Table 10 — Electrical Data for Units without Electric Heat MODEL SIZE HP FT Li4R VOLTS/PH/HZ SINGLE CIRCUIT BRANCH CIRCUIT MIN WIRE SIZE* AWG MCA MAXMUM OVERCURRENT PROTECION 18 1 /3 2.9 208/230/1/60 3.6 15 14 24 1 /3 2.9 208/230/1/60 3.6 15 14 30 1 /2 4.2 208/230/1/60 5.3 15 14 36 1 /2 4.2 208/230/1/60 5.3 15 14 42 1 /2 4.2 208/230/1/60 5.3 15 14 48 3/4 6.1 208/230/1/60 7.6 15 14 60 3/4 6.1 208/230/1/60 7.6 15 14 * Use copper wire only. Use 75 ° C only in this application. When using non-metallic (NM) sheathed cable, wire size required should be based on that of 60 ° C conductors, instead of wire sizes shown in table above per NEC Article 336-26. NOTE: If branch circuit wire length exceeds 100 ft (30 m), consult NEC 215-2 to determine maximum wire length. Use 2% voltage drop. FLA -Full Load Amps SCCR (Short Circuit Current Rating) = 5kA rms, symmetrical, 230V Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 13 FJM: Product Data PERFORMANCE DATA (cont.) Table 11— Electric Heater Internal Protection HEATER kW PHASE FUSE QTY/SIZE CKT BKR* QTY/SIZE 5 1 — 1 /60 8 1 — 1 /60 9 1/3 — — 10 1 — 1/60 15 1 2130-2160 2/60 15 3 — — 18 3 — — 20 1 4/60 2/60 24 1 /3 6/60 — 30 1 /3 6/60 — * All circuit breakers are 2 pole. When using units with 20-, 24-, and 30-kW electric heaters, maintain a 1-in. (25mm) clearance from combustible materials to discharge plenum and ductwork and maintain a distance of 36-in (914mm) from the unit. Use an accessory downflow base to maintain proper clearance on downflow installations. Use flexible connectors between ductwork and unit to prevent transmission of vibration. When electric heater is installed, use heat resistant material for flexible connector between ductwork and unit at discharge connection. Ductwork passing through unconditioned space must be insulated and covered with vapor barrier. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 14 PERFORMANCE DATA (cont.) Table 12 — Accessory Heater Electrical Data HEATER PART NO. kW P A SE INTERNAL CIRCUIT PROTECTION HEATER AMPS 208/230V MIN AMPACITY 208/230V` BRANCH CIRCUIT Min Wire Size (AWG) 2081230 Min Gnd Wire Size 208/230V Max Fuse/Ckt Bkr Amps 208/230V Single Circuit Dual Circuit Single Circuit Dual Circuit Single Circuit Dual Circuit Single Circuit Dual Circuit Single Circuit Dual Circuit 240V 208V L1,L2 L3,L4 L1,L2 L3,L4 L1,L2 L3,L4 L1,L2 L3,L4 L1,L2 L3,L4 EHC05CKN*t 5 3.8 1 None 18.1/20.0 — — 26.0/28.4 — — 10/10 — — 10/10 — — 30/30 — — EHC05CKN 5 3.8 1 None 18.1/20.0 — — 26.3/28.6 — — 10/10 — — 10/10 — — 30/30 — — EHC07CKB 5 3.8 1 None 18.1/20.0 — — 26.3/28.6 — — 10/10 — — 10/10 — — 30/30 — — EHC05BKN** 5 3.8 1 None 18.1/20.0 — — 31.2/33.5 — — 8/8 — — 10/10 — — 35/35 — — EHC05BKB** 5 3.8 1 Ckt Bkr 18.1/20.0 — — 31.2/33.5 — — 8/8 — — 10/10 — 35/35 — — EHC07CKN 8 6.0 1 None 28.9/32.0 — — 44.7/48.5 — — 8/8 — — 10/10 — — 45/50 — — EHC07CKN 8 6.0 1 None 28.9/32.0 — — 39.8/43.6 — — 8/8 — — 10/10 — — 45/50 — — EHC07CKB 8 6.0 1 None 28.9/32.0 — — 39.8/43.6 — — 8/8 — — 10/10 — 45/50 — — EHC07BKB 8 6.0 1 Ckt Bkr 28.9/32.0 — — 44.7/48.5 — — 8/8 — — 10/10 — — 45/50 — — EHC09BKCN 9 6.8 1 None 32.8/36.0 — — 49.5/53.5 — — 8/6 — — 10/10 — — 50/60 — — EHC09BKCNtt 9 6.8 3 None 18.8/20.8 — — 32.0/34.5 — — 8/8 — — 10/10 — — 35/35 — — EHC10BKN 10 7.5 1 None 36.2/40.0 — — 53.8/58.5 — — 6/6 — — 10/10 — — 60/60 — — EHC10CKN 10 7.5 1 None 36.2/40.0 — — 48.9/53.6 — — 6/6 — — 10/10 — — 60/60 — — EHC10CKB 10 7.5 1 None 36.2/40.0 — — 48.9/53.6 — — 6/6 — — 10/10 — — 60/60 — — EHC10BKB 10 7.5 1 Ckt Bkr 36.2/40.0 — — 53.8/58.5 — — 6/6 — — 10/10 — — 60/60 — — EHC15BKF*t 15 11.3 1 Fuse 54.2/59.9 36.2/40.0 18.1/20.0 76.3/83.4 53.8/58.5 22.7/25.0 4/4 6/6 10/10 818 1 10/10 10/10 80/90 60/60 25/25 EHC15BKB 15 11.3 1 Ckt Bkr — 36.2/40.0 18.1/20.0 — 53.8/58.5 22.7/25.0 — 6/6 10/10 — 10/10 10/10 — 60/60 25/25 EHC15BHN 15 11.3 3 None 31.3/34.6 — — 47.7/51.8 — — 8/6 — — 10/10 — — 50/60 — — EHC18BHN 18 13.5 3 None 37.6/41.5 — — 55.5/60.4 — — 6/6 — — 10/8 — — 60/70 — — EHC20BKF## 20 15.0 1 Fuse 72.3/79.9 36.2/40.0 36.2/40.0 98.9/108.4 53.8/58.5 45.3/50.0 3/2 6/6 8/8 8/6 10/10 10/10 100/110 60/60 50/50 EHC20BKB 20 15.0 1 Ckt Bkr — 36.2/40.0 36.2/40.0 — 53.8/58.5 45.3/50.0 — 6/6 8/8 — 10/10 10/10 — 60/60 50/50 24 18.0 3 Fuse 50.1/55.4 — — 71.2/77.8 — — 4/4 — — 8/8 — — 80/80 — — EHC25BHCFRRR 24 18.0 1 Fuse 86.7/95.5 — — 116.9/127.9 — — 1/1 — — 6/6 — — 125/150 — — 30 22.5 3 Fuse 62.6/69.2 — — 86.8/95.0 — — 3/3 — — 8/8 — — 90/100 — — EHC30BHCF 30 22.5 1 Fuse 109.0/120.0 — — 1 144.8/158.5 — — 0/00 — — 6/6 — — 5-0/1 55 — I — *. Includes blower motor amps of largest fan coil used with heater. t. Copper wire must be used. If other than uncoated (non -plated), 75°C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). $. For fan coil sizes 24-42. **. For fan coil sizes 48-60. TT. Field convertible to 3 phase. 11. Single circuit application of F 15 and F20 heaters requires single -point wiring kit accessory. ***.Field convertible to 1 phase, single or multiple supply circuit. Table 13 - Field Multipoint Wiring or 24- and 30-kW Single Phase HEATER PART NO. kW PHASE HEATER AMPS 208/230V MIN AMPACITY 208/230V* MIN WIRE SIZE (AWG) 208/230Vt MIN GND WIRESIZE 2081230V MAX FUSE/CKT BKR AMPS 208/230V MAX WIRE LENGTH 208/230V (FT)$ 240V 208V L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 EHC25BHCF** 24 18.0 1 28.9/32.0 28.9/32.0 28.9/32.0 44.7/48.5 36.2/40.0 36.2/40.0 8/8 8/8 8/8 10/10 45/50 40/40 40/40 59/60 73/73 73/73 EHC30BHCF** 30 22.5 1 36.2/40.0 36.2/40.0 36.2/40.0 53.8/58.5 45.3/50.0 45.3/50.0 6/6 8/8 8/8 10/10 60/60 50/50 50/50 78/80 59/59 59/59 *. Includes blower motor amps of largest fan coil used with heater. t. Copper wire must be used. If other than uncoated (non -plated), 75°C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). $. Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. **. Field convertible to 1 phase, single or multiple supply circuit. FJM: Product Data Table 14 — Accessories ITEM ACCESSORY PART NO.* FAN COIL SIZE USED WITH 1. Disconnect Kit EBAC01 DSC3 All single phase 3kW - 10kW heaters 2. Downflow Base Kit Downflow Conversion Kitt EBAC01NCB 18 EBACO2NCB 24, 30, 36 EBAC03NCB 42,48 EBAC04NCB 60 3. EBAC01DFS Slope Coil Units-18, 24 EBACO2DFA A -Coil Units-30, 36, 42, 48, 60 4. Downflow/Horizontal Conversion Gasket Kit EBAC01GSK All 5. Horizontal Water Management Kit (25 pack) $ NAMA00125HC A -Coil Units-30, 36, 42, 48, 60 6. Single -Point Wiring Kit EBAC01 SPK1 Only with 15- and 20-kW Fused Heaters 7. Filter Available at retail big -box hardware stores. See Table 2 for sizes. $' Fan Coil Filter Cabinet Fan Coil Filter Media) ) NAMA0140FL 18 NAMA0170FL 24, 30, 36 NAMA0210FL 42,48 NAMA0240FL 60 9. PVC Condensate Trap Kit (50 pack) EBAC01CTK All 10. TXV Kit, R-410A, Aluminum Coils Only NAEB20101TX 18L, 24L, 30L, 36L, 42L NAEB20201TX 48L NAE620301TX 60L NAEB20401TX 60L 11. Door Gasket Kit ** 1191140 All 12. Accessory Quick Connect Kit NAMA00110QC All * Factory authorized and listed, field -installed. ** This kit is for replacement of factory installed gaskets if they are damaged or removed from the fan coil. t KFAHDO101SLP must also be purchased for down flow applications. $ KFAHDO101 SLP must also be purchased for down flow or horizontal applications. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 16 FJM: Product Data Accessory Kits Description — Suggested and Required Use 1. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE: Units for 3- through 10-kW electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a 1-in. (25mm) minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap -free seal with the floor. REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal -left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A -coils. REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications. 4. Downflow/Horizontal Conversion Gasket Kit This kit provides the proper gasketing of units when applied in either a downflow or horizontal application. REQUIRED USE: Fan coils in either downflow or horizontal applications. 5. Horizontal Applications - Water Management Kit This kit provides proper installation of fan coils under conditions of high static pressure and high relative humidity. SUGGESTED USE: All fan coils. 6. Single Point Wiring Kit The single point wiring kit acts as a jumper between L1 and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run two heavy -gauge, high -voltage wires into the fan coil rather than 4 light -gauge, high -voltage wires. SUGGESTED USE: Fan coils with 15- and 20-kW fused heaters only. 7. Filter Kit (12 pack) The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in turn, the efficiency of the system. SUGGESTED USE: To replace filters in fan coils. REQUIRED USE: All units unless a filter grille is used. 8. Fan Coil Filter Cabinet This cabinet is mounted to the fan coil on the return air end and designed to slip over the outer fan coil casing. The cabinets are insulated using the same insulation as production fan coils. They are designed for the removal of particulates from indoor air using FILXXFNC00(14, 17, 21, 24) media filter cartridges. These fan coil media filter cartridge kits are designed for the removal of particles from indoor air. The cartridge is installed in the return air duct next to the air handler or further upstream. SUGGESTED USE: All fan coils. 9. PVC Condensate Drain Trap Kit This kit consists of 50 PVC condensate traps. Each trap is pre -formed and ready for field installation. This deep trap helps the system make and hold proper condensate flow even during blower initiation. SUGGESTED USE: All fan coils. 10. TXV Kit These kits are designed to add TXVs to piston fan coils or convert R-410A fan coils to R-22 TXVs. 11. Door Gasket Kit This kit consists of specific adhesive -backed foam strips which are applied to the unit door and frame, limiting air leakage. 12. Accessory Quick Connect Kit This kit enables the installer to easily connect a 230V IAQ accessory (air purifier, electronic air cleaner, UV light, etc.) kit to a fan coil unit, eliminating the need to run a separate power supply to the accessory. Use of this kit may eliminate the requirement for a licensed electrician to complete the job (check local codes). © 2022 Carrier. All rights reserved. Edition Date: 11/22 Catalog No: FJM-21-01PD A Cartier Company Replaces: New Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 17