REVIEWED BLD2022-1340+SK-1+10.3.2022_7.11.49_PM+3143332CUT PLATE TIED WITH
SINGLE OR DOUBLE 16 GAGE STEEL STRAP
TOP PLATE SEE SECTION R602.6.1
FIREBLOCK AROUND
PIPE
WALL STUDS `
SEE SECTION R602.3
BOTTOM
PLATE
SILL
1 IN. BY 4 IN.
pIAQ¢NAL BRACF
LET INTO STUDS
JACK STUDS OR
TRIMMERS
SEE NOTE 2
STAGGER JOINTS 241N. OR
USE SPLICE PLATES
SEE SECTION R602,3.2
RECEIVED
Oct 05 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
FULI-4-EIGHT STUDS
ADJACENT TO HFADFR
SEE SECTION
RI502.T.5
SEE NOTE 1
BLD2022-1340
SOLID BLOCKING
FLOOR JOISTS
FOUNDATK]N
CRIPPLE wALL-
SEE SECTION R602.9
� � - - - - - WALL STFOUNDATLIDS
L ---
APPLY APPROVED SHEATHING OR BRACE
FkTERIQR WAL LS WITH 1 IN BY 41N DRACE3 LET
INTO STUDS AND PLATES A14D EXTENDING FROM
BOTTOM PLATE TO TOP PLATE. OR OTHER
APPROVED METAL STRAP DEVICES INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. SEE SECTION R602.14_
ANCHOR BOLTS EMBEDDED ON
FOLIN DATION 8 FT_ O_C_ MAX.
CORNER AND PARTITION POSTS
r+ -�:& -4
NOTE: A THIRD STUD ANDIQR PARTITION INTERSECTION
BACKING STUDS SHALL BE PERMITTED TO BE OMITTED
THROUGH THE USE OF WCOO BACKUP CLEATS. METAL
DRYWALL CLIPS OR OTHER APPROVED DEVICES THAT
WILL SERVE AS ADEQUATE BACKING FOR THE FACNIQ
MATERIALS.
FIGURE R602.3(2)FRAMING DETAILS
NOTES:
1. PROVIDE 4x8 DOUG FIR HEADER FOR HEADER SPAN 6'-0" OR LESS.
2. PROVED MINIMUM (1) 2x JACK STUD AT EACH END OF HEADER.
3. REFERENCE 2018 INTERNATIONAL BUILDING CODE FOR REFERENCED SECTIONS.
PROJECT:
HUTMACHER - 23709 78th AVE W, EDMONDS, WA
DATE:
10/03/22
TITLE:
TYPICAL WALL OPENING DETAIL - HEADER
SKETCH NO.
SK-1