REVIEWED BLD2022-1340+SK-1+10.3.2022_7.11.49_PM+3143332CUT PLATE TIED WITH SINGLE OR DOUBLE 16 GAGE STEEL STRAP TOP PLATE SEE SECTION R602.6.1 FIREBLOCK AROUND PIPE WALL STUDS ` SEE SECTION R602.3 BOTTOM PLATE SILL 1 IN. BY 4 IN. pIAQ¢NAL BRACF LET INTO STUDS JACK STUDS OR TRIMMERS SEE NOTE 2 STAGGER JOINTS 241N. OR USE SPLICE PLATES SEE SECTION R602,3.2 RECEIVED Oct 05 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FULI-4-EIGHT STUDS ADJACENT TO HFADFR SEE SECTION RI502.T.5 SEE NOTE 1 BLD2022-1340 SOLID BLOCKING FLOOR JOISTS FOUNDATK]N CRIPPLE wALL- SEE SECTION R602.9 � � - - - - - WALL STFOUNDATLIDS L --- APPLY APPROVED SHEATHING OR BRACE FkTERIQR WAL LS WITH 1 IN BY 41N DRACE3 LET INTO STUDS AND PLATES A14D EXTENDING FROM BOTTOM PLATE TO TOP PLATE. OR OTHER APPROVED METAL STRAP DEVICES INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. SEE SECTION R602.14_ ANCHOR BOLTS EMBEDDED ON FOLIN DATION 8 FT_ O_C_ MAX. CORNER AND PARTITION POSTS r+ -�:& -4 NOTE: A THIRD STUD ANDIQR PARTITION INTERSECTION BACKING STUDS SHALL BE PERMITTED TO BE OMITTED THROUGH THE USE OF WCOO BACKUP CLEATS. METAL DRYWALL CLIPS OR OTHER APPROVED DEVICES THAT WILL SERVE AS ADEQUATE BACKING FOR THE FACNIQ MATERIALS. FIGURE R602.3(2)FRAMING DETAILS NOTES: 1. PROVIDE 4x8 DOUG FIR HEADER FOR HEADER SPAN 6'-0" OR LESS. 2. PROVED MINIMUM (1) 2x JACK STUD AT EACH END OF HEADER. 3. REFERENCE 2018 INTERNATIONAL BUILDING CODE FOR REFERENCED SECTIONS. PROJECT: HUTMACHER - 23709 78th AVE W, EDMONDS, WA DATE: 10/03/22 TITLE: TYPICAL WALL OPENING DETAIL - HEADER SKETCH NO. SK-1