Loading...
APPROVED BLD PLN RESUB 1-BLD2023-0880-Building Elevations+7.27.2023_4.08.24_PM+3693715ABBREVIATIONS GENERAL AD ACCESS DOOR ADD'L ADDITIONAL AF AIR FOIL AFF ABOVE FINISHED FLOOR AFR ABOVE FINISHED ROOF ALT ALTITUDE OR ALTERNATE AMP AMPERE AP ACCESS PANEL APD AIR PRESSURE DROP ARCH ARCHITECT AS AIR STREAM ATC AUTOMATIC TEMPERATURE CONTROL ATM ATMOSPHERE AVE AVERAGE BHP BRAKE HORSEPOWER BLDG BUILDING BOD BOTTOM OF DUCT BTU BRITISH THERMAL UNIT BTUH BTU PER HOUR CENT CENTRIFUGAL CFM CUBIC FEET PER MINUTE CLG CEILING OR COOLING CO CARBON MONOXIDE COL COLUMN CONN CONNECTION CONTR CONTRACTOR D DRAIN OR DEPTH DB DRY BULB TEMPERATURE DEG DEGREE DDC DIRECT DIGITAL CONTROL DIA DIAMETER DIM DIMENSION DN DOWN DP DIFFERENTIAL PRESSURE EA EACH OR EXHAUST AIR EAT ENTERING AIR TEMPERATURE EFF EFFICIENCY ELEC ELECTRICAL ELEV ELEVATION ENT ENTER ESP EXTERNAL STATIC PRESSURE EWT ENTERING WATER TEMPERATURE EXH EXHAUST EXIST EXISTING EXT EXTERNAL EXP EXPANSION F FAHRENHEIT FA FREE AREA FC FLEXIBLE CONNECTION FLA FULL LOAD AMPS FLEX FLEXIBLE FLRDR FLOOR DRAIN FO FLAT OVAL FPM FEET PER MINUTE FPS FEET PER SECOND FS FLOW SWITCH FT FEET GA GAUGE GAL GALLONS GALV GALVANIZED GC GENERAL CONTRACTOR GPH GALLONS PER HOUR GPM GALLONS PER MINUTE GRD GRADE GWB GYPSUM WALL BOARD HGT HEIGHT HP HORSEPOWER OR HIGH POINT HR HOUR HTG HEATING HZ HERTZ (FREQUENCY, CYCLES PER SECOND) ID INSIDE DIAMETER IN INCHES L LENGTH LAT LEAVING AIR TEMPERATURE LB POUND LF LINEAR FEET LP LOW POINT LRA LOCKED ROTOR AMPS LUVR LOUVER LVG LEAVING LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MBH THOUSAND BTUH MCA MINIMUM CIRCUIT AMPS MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM N/A NOT APPLICABLE NC NORMALLY CLOSED OR NOISE CRITERIA NIC NOT IN CONTRACT NO NORMALLY OPEN No NUMBER NOM NOMINAL NTS NOT TO SCALE OA OUTSIDE AIR OAI OUTSIDE AIR INTAKE OD OUTSIDE DIAMETER OV OUTLET VELOCITY PD PRESSURE DROP PH PHASE PBG PLUMBING POC POINT OF CONNECTION TO EXISTING POS PROVIDED BY OTHER SECTION PSI POUNDS PER SQUARE INCH QTY QUANTITY R RADIUS RA RETURN AIR RET RETURN REQ'D REQUIRED RH RELATIVE HUMIDITY RLA RUNNING LOAD AMPS RLF RELIEF RM ROOM RPM REVOLUTIONS PER MINUTE SCH SCHEDULE SCR SCREEN SDET SMOKE DETECTOR SEN SENSIBLE SHC SENSIBLE HEAT CAPACITY SP STATIC PRESSURE SPECS SPECIFICATIONS SF SQUARE FEET SS STAINLESS STEEL STL STEEL SUP SUPPLY T TEMPERATURE TA THROWAWAY TEFC TOTALLY ENCLOSED FAN COOLED TEMP TEMPERATURE TSTAT THERMOSTAT TON 12,000 BTUH COOLING CAPACITY TOT TOTAL TYP TYPICAL V VOLTS (ELECTRICAL) VEL VELOCITY W WIDTH OR WATT W/ WITH WB WET BULB TEMPERATURE WMS WIRE METAL SCREEN W/O WITHOUT WPD WATER PRESSURE DROP WTD WATER TEMPERATURE DIFFERENCE X EXISTING EQUIPMENT TO BE REMOVED XM EXISTING EQUIPMENT TO REMAIN XN NEW LOCATION OF RELOCATED EQUIPMENT XR EXISTING EQUIPMENT TO BE RELOCATED CHILLED WATER CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY DUCT ACD AUTOMATIC CONTROL DAMPER AFMS AIR FLOW MEASURING STATION AL ACOUSTICAL DUCT LINER BDD BACKDRAFT DAMPER BOD BOTTOM OF DUCT CD CEILING DIFFUSER DIFF DIFFUSER FBD FLAT BOTTOM DUCT FO FLAT OVAL LD LINEAR DIFFUSER MUA MAKE-UP AIR OED OPEN END DUCT PAD PRIMARY AIR DAMPER RA RETURN AIR SA SUPPLY AIR SL SOUND LINING SR SUPPLY REGISTER TA THROW AWAY OR TRANSFER AIR TG TRANSFER GRILLE TOD TOP OF DUCT TR TRANSFER TSP TOTAL STATIC PRESSURE (IN. WG) TV TURNING VANES VD VOLUME DAMPER AF AIR FILTER OR AIR FOIL DDC DIRECT DIGITAL CONTROL EHC ELECTRICAL HEATING COIL FPB FAN POWERED BOX FCU FAN COIL UNIT RHC REHEAT COIL SF SUPPLY FAN TD TRANSFER DUCT AAV AUTOMATIC AIR VENT ACV AUTOMATIC CONTROL VALVE ATV ATMOSPHERIC VENT BOP BOTTOM OF PIPE CO CLEAN -OUT DOV DRAIN -OFF VALVE FOB FLAT ON BOTTOM REDUCER FOT FLAT ON TOP REDUCER MAV MANUAL AIR VENT TOP TOP OF PIPE V VENT CONTROLS ACD AUTOMATIC CONTROL DAMPER ACV AUTOMATIC CONTROL VALVE AFMS AIR FLOW MEASURING STATION ALM ALARM CT CURRENT TRANSFORMER (STATUS FEEDBACK) DAT DISCHARGE AIR TEMPERATURE SENSOR DDC DIRECT DIGITAL CONTROL LAT LEAVING AIR TEMPERATURE SENSOR MAT MIXED AIR TEMPERATURE SENSOR OSA OUTSIDE AIR OS OCCUPANCY SENSOR (CO2) NC NORMALLY CLOSED (ON LOSS OF POWER) NO NORMALLY OPEN (ON LOSS OF POWER) SD SMOKE DETECTOR SP STATIC PRESSURE SENSOR SPD SPEED CONTROL S/S START/STOP T TEMPERATURE SENSOR/THERMOSTAT TR TRANSFORMER RECTANGULAR DUCT ROUND DUCT FLAT OVAL DUCT ROUND SUPPLY DUCT UP ROUND SUPPLY DUCT DOWN Idx��Y�J,��'��1�1���1, RECT. SUPPLY DUCT DOWN :Z�1�1 � I �l :7 � r�J :7 � � �1�I� ��1, ROUND RETURN DUCT DOWN RETURN DUCT UP RETURN DUCT DOWN ROUND EXHAUST DUCT UP ROUND EXHAUST DUCT DOWN RECT. EXHAUST DUCT UP RECT. EXHAUST DUCT DOWN RECTANGULAR DUCT TO ROUND CEILING DUCT MOUNTED DIFFUSER/GRILLE TAKE -OFF TO DIFFUSER/GRILLE W/ FLEX DUCT CEILING DUCT MOUNTED DIFFUSER/GRILLE ACOUSTICALLY LINED DUCT EXTERNALLY WRAPPED DUCT BARE DUCT FLEXIBLE DUCT (DOUBLE LINE) FLEXIBLE DUCT (SINGLE LINE) W D 10x6 10x6 FO �` ,, 6"O 10x6 VD y� -. DUCTWORK W D RECTANGULAR RETURN/EXHAUST DUCT, W=WIDTH, D=DEPTH 10x6 AS VIEWED DIA ROUND RETURN/EXHAUST DUCT 10"O (DIA=INSIDE DIAMETER) STANDARD RADIUS ELBOW (R = W) SUPPLY/RETURN/EXHAUST R �W� FULL LENGTH SPLITTER VANES r r�r (R � W) SUPPLY/RETURN/ EXHAUST R �W� SPLIT TAKE -OFF RECTANGULAR WYE SUPPLY AD FIRE DAMPER ACCESS DOOR � AD� CHANGE OF ELEVATION (R)RISE OR (D)DROP � R/D SUPPLY/RETURN/EXHAUST 45° TAP TAKE -OFF 45° TAKE -OFF TRANSITION TO ROUND 45° TAKEOFF 90° RECT. TAP � 1 TAKE -OFF + + + SQUARE TO ROUND BELLMOUTH CONNECTION CONNECTION CONVERGE RETURN/EXHAUST W/45° TAKE -OFFS OPEN END DUCT W/ 1/2"x1/2" WMS FIRE DAMPER FD FIRE -SMOKE DAMPER FSD CEILING RADIATION DAMPER CRD � AIR DISTRIBUTION TERMINALS SUPPLY DIFFUSER � NECK SIZE: � AIR TERMINAL CALLOUT TYPE: — A 10"� CFM: �TYP2 RETURN GRILLE AIR INTAKE �� EXHAUST GRILLE � AIR DISCHARGE CEILING R.A. SOUND BOOT �� GOOSENECK RELIEF/EXHAUST HOOD � �i � it � � II DUCT MOUNTED "BULLS EYE" DIFFUSER GOOSENECK INTAKE AIR HOOD \; � / i� II MODUBLOC DIFFUSER � � LINEAR SLOT DIFFUSER DOUBLE DEFLECTION END OF BRANCH ; --T„ DOUBLE DEFLECTION BRANCH SUPPLY DIFFUSER �__r� MOUNTED SUPPLY DIFFUSER 1 CONTROLS LEGEND OT THERMOSTAT OS OCCUPANCY SENSOR (CO2) O SPACE TEMPERATURE SENSOR O AVERAGING SPACE TEMPERATURE SENSOR MOTORIZED DAMPER SD DUCT MOUNTED SMOKE DETECTOR DUCT MOUNTED PRESSURE SENSOR DIFFERENTIAL PRESSURE SENSOR 24 MODULATING DAMPER ACTUATOR 2-POSITION DAMPER ACTUATOR BACKDRAFT DAMPER OAT DAT MAT SP O SS �� SPACE PRESSURE SENSOR OUTSIDE AIR TEMP SENSOR DISCHARGE AIR TEMP SENSOR MIXED AIR TEMP SENSOR DUCT STATIC PRESSURE SENSOR HUMIDISTAT (SPACE MOUNT) HUMIDISTAT (DUCT MOUNT) DUCT MOUNTED SAIL SWITCH ROUND CONTROL DAMPER RECTANGULAR CONTROL DAMPER BAROMETRIC RELIEF DAMPER DIAGRAM EQUIPMENT SYMBOLS EQUIPMENT CALLLOUT EQ-X FAN POWERED VAV TERMINAL FILTER BANK FAN POWERED VAV TERMINAL WITH REHEAT COIL REHEAT MODULE C SINGLE DUCT COOLING COIL VAV TERMINAL C OUTDOOR CONDENSING � DUAL DUCT UNIT OR HEAT PUMP VAV TERMINAL ,� _ � 2-WAY AUTOMATIC CONTROL i ; � i ���� VALVE (MODULATING) PACKAGED ROOFTOP UNIT � - y - � ���� I \ � � 3-WAY AUTOMATIC CONTROL � - y � VALVE (MODULATING) \\�i REQUIRED CLEARANCE AREA GOOSENECK STYLE ROOF HOOD \' i "CHINA CAP" STYLE ROOF HOOD �"� � i �--� FLAT STYLE ROOF HOOD I I i I L__J PERIMETER STEAM HEAT � CONVECTOR UNIT I . DUCTLESS SPLIT WALL MOUNTED FAN COIL UNIT � � VRF HEAT PUMP UNIT � Q APPROVED PLANS MUST BE WATER SOURCE HEAT PUMP WITH SIDE RETURN WATER SOURCE HEAT PUMP WITH END RETURN EXPIRES: 09/08/2024 APPROVED BY PLANNING Jul 28 2023 �? ii cv FAN COIL UNIT �� 00 d' d7 CU PACKAGED TERMINAL AC OR HEAT PUMP ® C� CV VRF DUCTED FAN �� � COIL UNIT � � >� VRF HEAT RECOVERY MODULE � � � Q) � CEILING MOUNTED EXHAUST FAN � � � ('6 � � INLINE EXHAUST FAN � O a--� � CV ON JOB SITE A►LL WORK SUBJ CT PIPING LEGEf JD R CE T PT Q Av �MV BALL VALVE BUTTERFLY VALVE HOSE END BALL VALVE WITH CAP AND CHAIN PLUG VALVE 2-WAY MODULATING PRESSURE INDEPENDENT ACV AUTOMATIC FLOW LIMITING VALVE (PRESSURE INDEPENDENT) COMBINATION FLOW METER/SHUT-OFF/BALANCING VALVE (CIRCUIT SETTER) UNION BLIND FLANGE PIPE -CAPPED City Of E d m o n s PRESSURE/THERMOMETER W LL Building Department ---------------------------------- ----- AIRVENT -AUTOMATIC Work HVAC UNITS AIR VENT -MANUAL ----------------------------------- -- Address 21616 76TH AVE W DIRECTION OF FLOW - -_ Owner EDMONDS MEDICAL FLEXIBLE CONNECTOR PIPE -DOWN Approved Date 07/31 /2023 PIPE - UP Building Official Er�,c/ CLEANOUT FOR CONDENSATE ��r�it Number BLD2023-08�0 PIPE BREAK (SINGLE LINE) BALL VALVE See Structural calculation packet for anchorage details. REDUCER ■..� � � ■ ■ Jul 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Project Title: ELEVATION EDMONDS MEDICAL 21616 76TH AVE W EDMONDS, WA 98026 Sheet Title: SYMBOLS AND LEGENDS Designed By: SKD Drawn By: SKD Project No: Date: 06/05/2023 Sheet Number: M-1.0 GENERAL HVAC NOTES 1. MECHANICAL DESIGN, INSTALLATION &COORDINATION SHALL COMPLY WITH THE FOLLOWING CODES: A. SEATTLE MECHANICAL CODE (SMC) 2018 B. SEATTLE ENERGY CODE (SEC) 2018 2. THE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. ADDITIONAL MECHANICAL NOTES MAY BE INDICATED ON EACH MECHANICAL DRAWING. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 3. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION INCLUDING, LOUVERS, CONCRETE EQUIPMENT PADS FLASHING DETAILS, ETC. 4. REFER TO ARCHITECTURAL DRAWING FOR ROOM ELEVATIONS. LOCATE MECHANICAL DEVICES SUCH AS TEMPERATURE SENSORS, HUMIDISTATS, PANELS, ETC. SO THAT THEY DO NOT CONFLICT WITH GENERAL CONSTRUCTION (WAINSCOT, DOOR HARDWARE, ETC.) NOR WITH ELECTRICAL SYSTEM (LIGHT SWITCHES, SPEAKERS, OUTLETS, ETC.). 5. MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR GRILLS AND DIFFUSERS. FIELD COORDINATE ACTUAL LOCATIONS BY REFERRING TO ARCHITECTURAL DRAWINGS, REFLECTED CEILING PLANS, AND OTHER CEILING OR SURFACE MOUNTED DEVICES PLANS. INSTALL EQUIPMENT IN CONFORMANCE WITH ARCHITECTURAL FEATURES IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE INDICATED ON ARCHITECTURAL DRAWINGS. WHERE EQUIPMENT IS NOT INDICATED ON ARCHITECTURAL DRAWINGS, OBTAIN DIRECTION FROM ARCHITECT PRIOR TO INSTALLATION. 6. GENERALLY DUCTWORK PLANNED TO BE TIGHT TO STRUCTURE WITH PIPING BELOW DUCTWORK AND BETWEEN LIGHT FIXTURES. ADJUST AS NECESSARY. 7. COORDINATE LOCATIONS OF MECHANICAL EQUIPMENT AND DUCTWORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL AND SERVICE ACCESS DUE TO EQUIPMENT MAINTENANCE. 8. ARRANGE HVAC EQUIPMENT SO THAT ACCESS CLEARANCES INDICATED BY DRAWINGS, REQUIRED BY CODES, AND RECOMMENDED BY MANUFACTURER ARE PROVIDED. 9. WHERE NECESSARY, PROVIDE ACCESS PANELS/DOORS IN DUCTWORK AS INDICATED FOR INSPECTION AND MAINTENANCE FOR ALL SMOKE/FIRE DAMPERS. 10. GENERAL CONTRACTOR SHALL PROVIDE ACCESS TO FIRE AND/OR COMBINATION FIRE/SMOKE DAMPERS THROUGH ACCESS DOORS IN HARD CEILINGS AND WALLS. WHERE ACCESS DOORS PENETRATE FIRE RATED SYSTEMS THEY SHALL BE RATED IN ACCORDANCE WITH IBC REQUIREMENTS. 11. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL CHARACTERISTICS OF MECHANICAL EQUIPMENT (VOLTAGES, ETC). 12. ELECTRICAL CHARACTERISTICS OF LISTED EQUIPMENT SHALL BE VERIFIED BY CONTRACTOR DURING SUBMITTAL PROCESS. ANY ELECTRICAL CHARACTERISTICS THAT DEVIATE FROM THOSE LISTED SHALL BE IDENTIFIED BY THE CONTRACTOR, SUBMITTED TO THE ENGINEER FOR APPROVAL AND COORDINATED WITH DIVISION 16 (OR DIVISION 26) PRIOR TO INSTALLATION OF EQUIPMENT AS REQUIRED TO PROPERLY SERVE EQUIPMENT. 13. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW OFFSETS WHICH MAY BE REQUIRED. PROVIDE OFFSETS AS REQUIRED AT NO ADDITIONAL COST. 14. REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FITTINGS, VALVES, ETC. FLOOR PLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE ROUTING ONLY. 15. DUCTS AND PIPES INDICATED WITHOUT DIMENSIONS SHALL BE SIZED PER PRECEDING UPSTREAM DUCT AND PIPE SECTIONS. 16. DUCTWORK SIZES SHOWN ARE CLEAR INSIDE DIMENSION. 17. PROVIDE FABRICATED STEEL MEMBER SUPPORTS AS REQUIRED BY MANUFACTURER'S INSTALLATION INSTRUCTIONS, AS INDICATED ON DRAWINGS, OR IN SPECIFICATIONS FOR INSTALLATION OF EQUIPMENT. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL. 18. IF REQUIRED FOR INSTALLATION OF PIPES, DUCTS, AND EQUIPMENT, PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO MEET SUPPORT REACTIONS (FORCES, MOMENTS, AND DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. 19. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS, UNLESS INDICATED ON STRUCTURAL DRAWINGS OR AS APPROVED BY THE STRUCTURAL ENGINEER. 20. ON ALL EXTENDED PLENUMS CONNECTED TO A DISCHARGE OUTLET ON A SUPPLY AIR DEVICE SUCH AS A WATER SOURCE HEAT PUMP, FAN COIL UNIT, FAN POWERED VAV TERMINAL, PROVIDE 1" THICK INTERIOR ACOUSTICAL LINER IN THE FIRST 4 FT. OF LENGTH. NO TAP -INS SHALL OCCUR IN THIS SECTION. 21. PROVIDE DUCT LINING FOR THE FOLLOWING DUCTWORK: A. ALL AIR TRANSFER DUCTS AND CEILING RELIEF GRILLS B. ALL MIXED AIR AND EXHAUST AIR PLENUMS C. ALL OUTDOOR AIR DUCTS OR PLENUMS 22. PROVIDE A VOLUME DAMPER FOR EACH SUPPLY BRANCH, RETURN BRANCH (DUCTED ONLY), &EXHAUST BRANCH WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH THE BRANCH, AND ELSEWHERE AS NOTED ON THE DRAWINGS OR IN SPECIFICATIONS. 23. DUCTWORK STATIC PRESSURE AND SEAL CLASS, BASED ON SMACNA STANDARDS. 24. REFER TO WASHINGTON STATE NREC COMPLIANCE REQUIREMENTS ON DRAWING SCHEDULE SHEETS FOR ADDITIONAL MECHANICAL PROVISIONS. 25. PROVIDE ECONOMIZERS IN ACCORDANCE WITH SEC (2018). 26. SEAL DUCT AND PLENUM IN ACCORDANCE WITH SEC (2018). 27. BALANCE HVAC SYSTEM IN ACCORDANCE WITH SEC (2018). 28. COMMISSION AND COMPLETE MECHANICAL SYSTEMS IN ACCORDANCE WITH SEC (2018). 29. PROVIDE COMPLETION/RECORD DRAWINGS IN ACCORDANCE WITH SEC (2018). 30. INSULATE DUCT AND PLENUM IN ACCORDANCE WITH SEC (2018). 31. INSULATE PIPING IN ACCORDANCE WITH SEC (2018). 32. PROVIDE THERMOSTATIC CONTROLS IN ACCORDANCE WITH SEC (2018). 33. ENSURE SETPOINT OVERLAP RESTRICTION IN ACCORDANCE WITH SEC (2018). 34. PROVIDE THERMOSTATIC SETBACK CAPABILITIES IN ACCORDANCE WITH SEC (2018). 35. EQUIP SHUTOFF DAMPER CONTROLS IN ACCORDANCE WITH SEC (2018). 36. ENSURE VENTILATION IN ACCORDANCE WITH SEC (2018). 37. PROVIDE DEMAND CONTROL VENTILATION IN ACCORDANCE WITH SEC (2018). 38. PROVIDE OCCUPANCY SENSORS IN ACCORDANCE WITH SEC (2018). 39. ENSURE ELECTRIC MOTOR EFFICIENCY IN ACCORDANCE WITH SEC (2018). 40. PROVIDE SINGLE DUCT VARIABLE AIR VOLUME (VAV) SYSTEMS WITH TERMINAL DEVICES IN ACCORDANCE WITH SEC (2018). 41. PROVIDE DUAL DUCT AND MIXING VAV SYSTEMS WITH TERMINAL DEVICES IN ACCORDANCE WITH SEC (2018). 42. ENSURE WORK ACCESS CLEARANCE FOR ALL MECHANICAL ELECTRICAL PANELS IS IN ACCORDANCE TO THE NEC (2018). 43. ALL EQUIPMENT, DUCT, AND OTHER ITEMS INSTALLED WITHIN THE RETURN PLENUM MUST BE NONCOMBUSTIBLE, OR SHALL BE LISTED AND LABELED AS HAVING A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE TO ASTM E 84 OR UL 723. RTU SCHEDULE MARK MANUFACTURER MODEL DESCRIPTION AIRFLOW N MBTU G SEER HTG CPY VOLTAGE MCA WEIGHT REMARKS RTU-1 RUUD RHPCZR060AC000OACCAO REPLACEMENT RTU 2000 57.5 13.4 57.5 208-230/60/3 50 621 1 RTU-2 RUUD RHPCZR048AC000OACCAO REPLACEMENT RTU 1600 46.5 13.4 46.0 208-230/60/3 40 618 2 RTU-3 RUUD RHPCZR048AC000OACCAO REPLACEMENT RTU 1600 46.5 13.4 46.0 208-230/60/3 40 618 2 NOTES: 1. REPLACING AN EXISTING 5-TON UNIT. 2. REPLACING AN EXISTING 4-TON UNIT. �' � � � I �� � �� � - �� ,�; '�_'� �� � � ��=llis�b�e� �� � '� a eh� A�Rr ,� �� �D�1f1 - � � '� �� ' � _" � . i� � s � I� i I �, r. ,� � � to - - IY . ash:, � ti M. � ' I :+ .� _ _ , a l�l Ie FlSll lY I IL I 1 LJ� Edmands Schaal District Stadium 3 �' V � n Apartments �Ilness Clinic. w � i Mtn st suu - 216th st sw n Leaves Premier Painting and Canstructian SW �o m �� 2118th St SW Park 212 21°3ih P15V� a SEAWEED Cannabi Edmands - Dispensary 215th Sit SW Aldercrest Health & Rehab Center h�eDanalci's �� v ib 216th St SW Swedish Edmands Campus Edmonds Oral Facial Surgery Ellie.laaadi, DDS, MSD, Orchid Periadantics and___f�f � Sraltle Implant Specialist- Meet E... Premier Therapy, ASSOCI�tOS 220th St SW adb 22ilth � SW WinCa Faads Panda Express ' c.4� ca -.,i Cart�.�' �' � a�L�Y��I'�I a 21 �6th St SW ..Swedish Urgent Care - Edmands RESUB Jul 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET INDEX SHEET NUMBER DESCRIPTION M-1.0 COVER SHEET M-1.1 PROJECT INFORMATION M-2.1 HVAC PLAN Be ka�aa��������1 LEGAL DESCRIPTION ,: {: Dicl�'s Drive-ln f;. Ir +�, ��� Red Drage�n� F?� er' Dang Ting,,Chun 22otn st 51w ,rl ,r1 I 21616 76th Ave W ADDRESS Edmonds, WA TAX PARCEL NUMBER 00461000100102 PROJECT CONTACTS CONTACT POSITION EMAIL TELEPHONE AARON CARTER PROJECT MANAGER aaron.carter@vitalmechanical.com 253-335-5271 LISA CASSADAY PROJECT ADVISOR lisa.cassaday@vitalmechanical.com 206-629-4828 STEVE DEPEW ENGINEER Steve@depewinc.com 206-229-7475 EXPIRES: 09/08/2024 V CV � � � YCV O •� C � � � L['} � CC} i37 � � N �� �C O � -1--� N � '� � � � Project Title: ELEVATION EDMONDS MEDICAL 21616 76TH AVE W EDMONDS, WA 98026 Sheet Title: PROJECT INFORMATION Revisions: Designed By: SKD Drawn By: SKD Project No: Date: 06/05/2023 Sheet Number: M-1.1 to '� T` / .A ' EXPIRES: 09/08/2024 � � �� � �i N � � o � N �� � C oL �� '� � o «} rn � �� �� c� � � o 0 �t � Project Title: ��ATION EDMONDS MEDICAL 21616 76TH AVE W EDMONDS, WA 98026 Sheet Title: HVAC PLAN Revisions: RESUB Designed By: SKD Jul 28 2023 Drawn By: SKD CITY OF EDMONDS DEVELOPMENT SERVICES Project No: DEPARTMENT Date: 06/05/2023 Sheet Number: HVAC SCALE: 1/16" — ,,_o., M-2.1 EXPIRES: 09/08/2024 Y •�p rn ;n.. ._ LJ � �'.I D �''.;' ;�'� N �� �.. � Lip C_) (.: I \ � � V N o O C d O 2 RTC! '� 1 RTC! U � s n� o � a RESUB Jul 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Project Title: EDMONDS MEDICAL 21616 76TH AVE W EDMONDS, WA 98026 Sheet Title: ELEVATION Revisions: Designed By: SKD Drawn By: SKD Project No: Date: 06/05/2023 ELEVATION SCALE: 1 /16" = 1'-0" Sheet Nu e . M-3.1