Loading...
APPROVED PLN BLD BLD2023-1018+Building_Elevations_Plans+8.11.2023_9.26.59_AM+3720531ABBREVIATIONS GENERAL -LEGEND 0 DIAMETER RTU EQUIPMENT TAG TYPE ABV ABOVE 2 EQUIPMENT TAG NUMBER ACH AIR CHANGES PER HOUR AD ACCESS DOOR 1 DETAIL OR DIAGRAM NUMBER AFF ABOVE FINISHED FLOOR M2.1 SHEET NUMBER WHERE DETAIL SHOWN AFG AVERAGE FINISHED GRADE AFUE ANNUAL FUEL UTILIZATION EFFICIENCY 1 SECTION LETTER AHU AIR HANDLING UNIT M2.1 SHEET NUMBER WHERE SECTION SHOWN AHRI AIR CONDITIONING, HEATING REFRIGERATION INSTITUTE AP ACCESS PANEL Al REVISION CLOUD AND CHRONOLOGICAL NUMBER ARI AMERICAN REFRIGERATION INSTITUTE BHP BRAKE HORSEPOWER DETAIL REFERENCE OUTLINE BDD BACKDRAFT DAMPER BOD BOTTOM OF DUCT POINT OF CONNECTION TO EXISTING OR TO BF BELOW FLOOR OTHERS' WORK BOT BOTTOM BTU(H) BRITISH THERMAL UNIT (HOUR) O1 KEY NOTE CALLOUT CD CONDENSATE CFM CUBIC FEET PER MINUTE 1Q PHOTO ID CALLOUT CONN CONNECTION COP COEFFICIENT OF PERFORMANCE ' ' ' ' ' WORK TO BE REMOVED DB DRY BULB/DECIBELS BELS H VAC - L E G E N D DIBFF DIFFERENTIAL DN DOWN DR DRAIN �► AIR FLOW DIRECTION E EXISTING EA EACH OR EXHAUST AIR SUPPLY OR OSA DUCT SECTION UP, ROUND OR EAT ENTERING AIR TEMPERATURE RECTANGULAR EC ELECTRICAL CONTRACTOR EER ENERGY EFFICIENCY RATIO RETURN, RELIEF OR EXHAUST DUCT SECTION UP, EF EXHAUST FAN ROUND OR RECTANGULAR EFF EFFICIENCY EG ELEV EXHAUST GRILLE ELEVATION SUPPLY OR OSA DUCT SECTION DOWN, ROUND 0 OR RECTANGULAR EQUIP EQUIPMENT ESP EXH EXTERNAL STATIC PRESSURE EXHAUST RETURN, RELIEF OR EXHAUST DUCT SECTION 0 DOWN, ROUND OR RECTANGULAR EXIST EXISTING F FURNACE EXISTING DUCTWORK °F FAHRENHEIT FF FINISHED FLOOR SLSM SOUND LINED SHEET METAL FLA FULL LOAD AMPERAGE FPM FEET PER MINUTE FC FLEXIBLE EQUIPMENT CONNECTION FREQ FREQUENCY FT FOOT OR FEET ° SFD COMBINATION FIRE AND SMOKE DAMPER G NATURAL GAS HP HORSEPOWER OR HEAT PUMP FD FIRE DAMPER HR HOUR HSPF HEATING SEASONAL PERFORMANCE FACTOR SD SMOKE DAMPER HT HEIGHT HVAC HEATING, VENTILATING, AIR-CONDITIONING EVADE VOLUME DAMPER HZ HERTZ IBC INTERNATIONAL BUILDING CODE M MD MOTORIZED DAMPER ID INSIDE DIAMETER IEER INTEGRATED ENERGY EFFICIENCY RATIO IFC INTERNATIONAL FIRE CODE TURNING VANES IFGC INTERNATIONAL FUEL GAS CODE IMC INTERNATIONAL MECHANICAL CODE IN INCHES ROUND TO ROUND 45° FITTING IN WG INCHES WATER GAUGE KW KILOWATT LAT LEAVING AIR TEMPERATURE/LATITUDE SQUARE TO SQUARE 45° FITTING LBS POUNDS LIN FT LINEAR FOOT OR FEET LRA LOCKED ROTOR AMPS SQUARE TO ROUND 45° FITTING MAX MAXIMUM MBH 1,000 BTU PER HOUR MCA MINIMUM CURRENT AMPS VD 45° FITTING FOR DUCTWORK MFR MANUFACTURER MIN MINIMUM GAS PIPING MOCP MAX OVER CURRENT PROTECTION NEC NATIONAL ELECTRICAL CODE O CARBON MONOXIDE SENSOR NIC NOT IN CONTRACT NOM NOMINAL O COORDINATED POWER LOCATION OD OUTSIDE DIAMETER/DIMENSION OPTS OPTIONS O REMOTE SENSOR OSA OUTSIDE AIR PH ELEC POWER PHASE (1 0 OR 30) O THERMOSTAT PN PROJECT NORTH (REFERENCE) POC POINT OF CONNECTION PRESS PRESSURE COMMISSIONING PSI POUNDS PER SQUARE INCH RA RETURN AIR OR RELIEF AIR MECHANICAL SYSTEMS RD ROOF DRAIN REF REFERENCE COPIES OF ALL APPLICABLE SERVICE AND EQUIPMENT DATA, AS WELL AS RPM REVOLUTIONS PER MINUTE PROJECT DOCUMENTATION THAT RELATES, SHALL BE PROVIDED TO THE RTU ROOFTOP UNIT OWNER AND MADE AVAILABLE TO THE AUTHORITY HAVING JURISDICTION (AHJ) SA SUPPLY AIR WITHIN 90 DAYS OF PROJECT COMPLETION AND IN ACCORDANCE WITH 2O15 SEER SEASONAL ENERGY EFFICIENCY RATIO WSEC SECTION C408.1, INCLUDING: SF SUPPLY FAN OR SQUARE FOOT OR FEET SMACNA SHEET METAL NATIONAL ASSOCIATION 1. PRELIMINARY COMMISSIONING REPORT AND OTHER RELATED REPORTS T TON (1 TON = 12,000 BTUH) SUCH AS AIR BALANCING, START-UP AND/OR PRESSURE TESTING DATA. TN TRUE NORTH (REFERENCE) T-STAT THERMOSTAT 2. RECORD DRAWINGS DEPICTING FINAL INSTALLATION CONFIGURATIONS OF TYP TYPICAL SYSTEMS AND EQUIPMENT. ULL ULTRA LOW LEAK DAMPER UNO UNLESS NOTED OTHERWISE 3. OPERATION AND MAINTENANCE EQUIPMENT MANUALS INCLUDING: UPC UNIFORM PLUMBING CODE MANUFACTURER'S INFORMATION WITH SPECIFIC MODEL NUMBERS AND W WATTS/WIDTH/WINDOW OPTIONS NOTED, CONTROLS DATA INCLUDING CALIBRATION AND SET WB WET BULB POINT INFORMATION, AND A SIMPLE NARRATIVE DESCRIPTION OF EACH WSEC WASHINGTON STATE ENERGY CODE SYSTEM. COPYRIGHT 2023 PINEHURST ENGINEERING, PLLC PROJECT DESCRIPTION THE PROJECT IS A LIKE -FOR -LIKE, ONE (1) SPLIT SYSTEM HEAT PUMP REPLACEMENT FOR A RESIDENTIAL SPACE, WITHIN A THREE-STORY ASSISTED LIVING BUILDING. THE BUILDING IS SITED WITHIN THE CITY OF EDMONDS (JURISDICTION), SNOHOMISH COUNTY, WASHINGTON. MECHANICAL PERMIT: UNDER APPLICATION RELATED ELECTRICAL PERMIT: UNDER SEPARATE PERMIT GENERAL NOTES 1. COORDINATE ALL NEW WORK WITH STRUCTURE AND OTHER TRADES. 2. FIELD VERIFY UNIT LOCATIONS, DROPS AND POSITIONS. 3. ALL LINE VOLTAGE WORK SHALL BE INSTALLED BY AN LICENSED COMMERCIAL ELECTRICIAN. 4. HVAC SYSTEMS HAVE BEEN DESIGNED PER THE REQUIREMENTS OF 2015 WSEC, IBC AND IMC. 5. ALL RIGGING AND LIFTING TO BE COORDINATED WITH THE BUILDING OWNERSHIP AND ANY OTHER CITY AND LOCAL JURISDICTIONS. APPLICABLE CODES 1. 2018 WASHINGTON STATE ENERGY CODE (WAC) CHAPTER 51-11) 2. 2018 INTERNATIONAL BUILDING CODE (WAC CHAPTER 51-50) 3. 2018 INTERNATIONAL MECHANICAL CODE (WAC CHAPTER 51-52) 4. 2018 INTERNATIONAL FUEL GAS CODE (WAC CHAPTER 51-52) 5. 2018 UNIFORM PLUMBING CODE (WAC CHAPTER 51-56) 6. NATIONAL ELECTRICAL CODE (NFPA 70 - WAC CHAPTER 296-46B) CODE COMPLIANCE NOTES 1. PROGRAMMABLE CONTROLS SHALL BE CAPABLE OF PROVIDING 5 DEGREE DEAD BAND AS REQUIRED BY 2018 WSEC SECTION C403.2.4.1.2. CONTROLS SHALL ALSO BE CAPABLE OF PROVIDING SEVEN DAY PROGRAMMABLE TEMPERATURE SETTINGS, AUTOMATIC SETBACK AND SHUTOFF AND OPTIMUM START AS REQUIRED BY 2018 WSEC SECTION C403.2.4.2 (OFF -HOUR CONTROLS). CONTROLS SHALL BE CONFIGURED TO PREVENT SIMULTANEOUS HEATING AND COOLING. 2. REPLACEMENT SPLIT SYSTEM AIR CONDITIONERS ARE OF THE SAME TYPE AND OUTPUT CAPACITY. 3. THIS PROJECT MEETS THE 2018 WSEC MINIMUM EFFICIENCY REQUIREMENTS FOR COOLING PROVIDED BY ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS PER TABLE C403.2.3(2)A WITH A SEER OF 12.2, WHICH MATCHES THE MINIMUM REQUIREMENT OF 11.2 SEER FOR EQUIPMENT SIZE CATEGORY <65 MBH (UNITARY AIR CONDITIONERS, SPLIT SYSTEM). MECHANICAL SCOPE THE PROJECT IS FOR THE REPLACEMENT OF ONE (2) EXISTING SPLIT SYSTEM HEAT PUMP HVAC UNITS. THE EXISTING SYSTEMS HAVE REACHED THE END OF THEIR USEFUL LIFE. THE NEW SYSTEMS ARE THE SAME TYPE AND SAME NOMINAL OUTPUT CAPACITY: 1. DEMO THE (2) OAC-1 EXISTING ROOFTOP HVAC UNITS & HEAT PUMP SERVING ROOMS 222 & 313. 2. THE REMOVAL AND DISPOSAL OF THE EXISTING UNITS FROM BUILDING SHALL BE IN A LAWFUL MANNER. RECLAIM EXISTING REFRIGERANT PER EPA STANDARDS; R-22 IS EXISTING REFRIGERANT PER EQUIPMENT NAME PLATE DATA. 3. PROVIDE AND INSTALL ONE (2) ROOFTOP HP UNITS & (2) FAN COILS IN PLACE OF THE EXISTING UNITS PER PLAN. NEW EQUIPMENT INCLUDES ELECTRIC DX COOLING, & BASIC ELECTRO-MECHANICAL CONTROLS. 4. DISCONNECT AND RE -CONNECT REPLACEMENT OAC & IFCU TO EXISTING ELECTRICAL SERVICES. RE -USE EXISTING ELECTRICAL DISCONNECT WHERE PRACTICABLE. LINE VOLTAGE WORK SHALL BE BY LICENSED COMMERCIAL ELECTRICIAN (UNDER SEPARATE PERMIT). 5. REUSE EXISTING THERMOSTAT AND CONTROL WIRING. 6. EQUIPMENT AND SYSTEM START-UP, TEST AND BALANCE, PROGRAMMING AND OWNER TRAINING FOR NEW EQUIPMENT, 0&M MANUALS AND RECORD DRAWINGS. 7. THERE IS AN EXISTING ±48" HIGH PERIMETER PARAPET WALL SURROUNDING ALL OF THE MECHANICAL EQUIPMENT ON THE ROOF. NO SCREENING IS NECESSARY. City Of Edmonds Building Department Work HEAT PUMP SPLIT SYSTEM IN RM 222 & 313 ----------------- Address 750 EDMONDS WAY ................................. ..........'--'--'--'--'--'--'--'- Owner SUNRISE OF EDMONDS Approved Date 08/21 /2023 Building Official Erg Permit Number BLD2023-1018 - ay Fir. � �7# i••, -- � �'�; .� • sr Z,• +t i f 1 ; PROJECT LOCATION - (2) ROOFTOP UNITS TO BE REPLACED --J BUILDING INFORMATION PROJECT ADDRESS: SUNRISE OF EDMONDS 750 EDMONDS WAY, EDMONDS, WA. 98020-5126 SITE CONTACT: RICHARD (425) 673-9700 PROPERTY OWNER: HCP SUN1 EDMONDS WA LLC., 2235 FARADAY AVE, SUITE #0, CARLSBAD, CA. 92009 TAX PARCEL NUMBER: 27032500306200 CONSTRUCTION TYPES: 11 - 1 HR FULLY SPRINKLERED PRIMARY OCCUPANCIES: CONVALESCENT CENTER APPROVED BY PLANNING ORIGINAL CONSTRUCT: 2004 �0- TOTAL BUILDING AREA: 60,052 SF Aug 28 2023 CLIMATE ZONE: 4C-SNOHOMISH THIS ASSISTED LIVING RESIDENTIAL PROPERTY HAS A SINGLE INSTUTUTIONAL RELATED OCCUPANCY AND BUILDING IDENTIFICATION ASSOCIATED WITH IT. ADDITIONAL PROPERTY AND BUILDING DATA CAN BE FOUND FROM THE CITY OF EDMONDS AND SNOHOMISH COUNTY ASSESSORS MAPS. DRAWING INDEX PAGE # SHEET # SHEET TITLE SCALE 1 MO.1 COVER SHEET, LEGEND AND NOTES N/A 2 M0.2 EQUIPMENT SCHEDULES & DATA N/A 3 M0.3 EQUIPMENT DATA N/A F4 M 1.1 ROOF PLAN - MECHANICAL 1 /8" = 1'-0" VICINITY MAP (BY GOOGLE MAPS, NOT TO SCALE) /- PROJECT LOCATION - 750 EDMONDS WAY, EDMONDS I71r . f f r. •' F FC ir ,s � r •r T �+AtrT- ir APrNo ' NORTH SITE MAP (BY GOOGLE MAPS, NOT TO SCALE) •' s. r 'w 1..� •1` �.. ti s� ��. 1 F77"%, NORTH LEGAL DESCRIPTION SEC 25 TWP 27 RGE 03 TH PTN SW1/4 SE1 /4 SW1 /4 DAF: BEG SW COR SD SUBJH NO1*00 36E ALG W LN 60.6FT TH N60*11 41 E 358.30 FT TO SWLY MGN OF SR-104 (EDMONDS WAY) AS CONVD PER DEED REC AF2180193; THS39*05 51 E PLW & 40FT SWLY C/L SR-104 ALG SWLY MGN AS CONVD TO ST OF WA BY DEEDS REC AFN'S 2180193, 2181901 & 2185476 DIST OF 201.69FT TAP OPST HWY ENGR STA 97+85; TH S01 *05 34W ALG SD MGN DIST OF46.49FT TAP 30FT NWLY & OPST HES 0-70; TH N88*29 44W DIST OF 382.17FT TO POB; PER CITY OF EDM LL-2000-134 REC AFN200303175004 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST B ON JOB SITE 8' 16' SCALE: 1/8" = 1'-0" F w � C L m Cn 00 ZI F IZI- 00 Q z O N O QZrn C 0- �N � = M 00 0 C .. °O w Q w 4J C)OW U) C Z =w �C LL 0 ~ :z Q L Sin o r+ 0 13>m _ vN z OQNER"T���M'9� •.. � �FWASry/n; 4559 6 Fcls-R ..• '' AL ENG�O6-2 3 °oa❑❑❑o�° 8- EXPIRES: 10/25/24 RECEIVED Aug 11 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NO. M001 COVER SHEET LEGEND AND NOTES PROJECT NO. 020-078B 8/6/23 OHP 222 OHP 313 FCU 222 FCU 313 OUTDOOR HEAT PUMP EQUIP NO. SERVICE CONNECTED INDOOR UNIT NOMINAL CAPACITY, TONS TOTAL COOLING CAPACITY, BTUH SEER I ELECTRICAL DATA SOUND POWER, DBA WEIGHT, LBS BASIS OF DESIGN 1(1) (2) (3) (4) VOLTAGE MOCP OHP-222 RM 222 FCU-222 1 1.5 18,000 15 230V/1 P 20 71 140 CARRIER 25SCA518AO03 OHP-313 IRM 313 FCU-313 1.5 18,000 15 230V/1 P 20 71 140 CARRIER 25SCA518AO03 (1) ARI LISTED WITH STANDARD FEATURES, INSTALLATION ACCESSORIES AND COMPRESSOR SHORT CYCLING PROTECTION, FILTER DRIER, REFRIGERANT LINE FILTER, LIQUID SOLENOID VALVE AND SAFETY PRESSURE SWITCHES. INSTALL REFRIGERANT TUBING AND LENGTH IN STRICT ACCORDANCE WITH MANUFACTURERES RECCOMENDATIONS. (2) WITH FACTORY OPTION DISCONNECT. (3) PROVIDE ALL REQUIRED ACCESSORIES FOR LONG -LINE AND LOW -AMBIENT APPLICATIONS. (4) ROUTING OF REFRIGERANT LINES FROM INDOOR TO OUTDOOR UNITS NOT SHOWN ON PLANS. CONTRACTOR TO FIELD COORDINATE ROUTING. HEAT PUMP COIL (1) EQUIP NO. SERVICE COIL CONFIGURATION SUPPLY FAN COOLING CAPACITY, TONS AUX ELEC HEAT KW (@ 230 V) ELECTRICAL DATA WEIGHT, LBS BASIS OF DESIGN AIRFLOW, CFM ESP, IN WC MIN OSA (CFM) MOTOR HP VOLTAGE MOCP FCU-222 RM 222 VERTICAL 600 0.5 75 1/3 1.5 2.3 208V/1P 20 120 CARRIER FJ4DNXA18L00 FCU-313 RM 313 VERTICAL 600 0.5 75 1/3 1.5 2.3 208V/1P 20 120 CARRIER FJ4DNXA18L00 NOTES: (1) PROVIDE CONDENSATE DRAIN TO NEAREST APPROVED RECEPTOR. PROVIDE CONDENSATE PUMP IF REQUIRED. Unit Report For 1.5T SS HP-SEER2 'roject: Sunrise Edmonds-1.5T SS HP 05/15/202: 'repared By: Performance Summary For 1.5T SS HP-SEER2 'roject: Sunrise Edmonds-1.5T SS HP 05/15/202, 'repared By: System Performance System: 25SC:A/FJ4D Actual Clg Airflow: 600.0 CFM System Quantity: 1 Standard Clg Airflow: 600.0 CFM _ Altitude: 0.0 ft Total Net Clg Capacity: 17.20 MBH i . Linear Pipe Length: 0.0 ft Net Sensible Clg Capacity: 13.10 MBH COP @ 47 F: 3.56 Htg HP Capacity: 17.50 MBH COP @ 17 F: 2.42 Htg HP Integrated Capacity: 17.50 MBH j SEER2 @ ARI Conditions: 14.3 Total System Power: 1.44 kW EER2 @ ARI Conditions: 12.0 HSPF2 @ ARI Conditions: 7.5 System Parameters Outdoor Unit Parameters Indoor Coil Parameters Unit Model: 25SCA Unit Model: FJ4D Outdoor Unit Parameters Indoor Coil Parameters Unit Size: 1.5 Tons (Size 18) Unit Size: 18,000 Btuh (Size 18) Unit Model: 25SCA518A003 Unit Model: FJ4DNXA18L00 Voltage: 208/230-1-60 V-Ph-Hz Cabinet Width: TXV/ 14 Inches Cabinet Unit Size (Nominal): 1.5 Tons (Size 18) Unit Size (Nominal): 18,000 Btuh (Size 18) Voltage: 208-1-60 V-Ph-Hz Voltage: 208/230-1-60 V-Ph-Hz Voltage: 208-1-60 V-Ph-Hz Heating Size: No Heat Clg Ent Air DB Ambient: 95.0 °F Ent Air DB: 80.00 °F Htg Ent Air DB Ambient: 47.0 °F Ent Air WB: 67.00 °F Outdoor Unit Dimensions and Weight Indoor Coil Dimensions and Weight Ent Enthalpy: 31.44 BTU/lb Unit Length: 31.1875 in Unit Length: 22.0625 in Lvg Air DB: 59.78 °F Unit Width: 31.1875 in Unit Width: 14.3125 in Lvg Air WB: 58.06 °F Unit Height: 28.6875 in Unit Height: 42.6875 in Lvg Enthalpy: 25.07 BTU/lb Unit Shipping Weight: 170. lb Unit Shipping Weight: 120. lb Htg Ent Air DB: 70.0 °F Htg Lvg Air DB: 97.0 °F RESIDENTIAL APPLICATIONS Heating Size (Nominal): No Heat This warranty is to the original purchasing owner and subsequent owners only to the extent and as stated in the Warranty Conditions and Total External Static Pressure: 0.50 in wg below. The limited warranty period in years, depending on the part and the claimant, is as shown in the table below. Limited Warrant Years Item Original Owner Subsequent Owner Parts 10* or 5 5 Compressor 10* (or 5) 5 'If properly registered within 90 days of original installation, otherwise 5 years (except in California and Quebec and other jurisdictions that prohibit warranty benefits conditioned on registration). See Warranty Conditions below. OTHER APPLICATIONS The warranty period is five (5) years on the compressor, and one (1) year on all other parts. The warranty is the original owner only and is not available for subsequent owners. Ordering Information Part Number Description Quantity Outdoor Unit 25SCA518AO03 25SCA Comfort Single Stage Heat Pump with Puron Refrigerant 1.5 Tons Cooling 1 15 SEER @ ARI Conditions Accessories KAACH1701AAA Crankcase Heater for Outdoor Unit 1 KSAFT0101AAA Evaporator Freeze Thermostat for Outdoor Unit 1 Indoor Coil FJ4DNXA181-00 FJ41D Base Series Fan Coil with Puron 18000 BTU Cooling 208/230-1- 60 1 TXV/ 14 Inches Cabinet Aluminum Accessories Residential Carrier Products Bldr 1.37 rdye '3 u1 I I Electrical Data Outdoor Electrical Data Indoor Electrical Data Unit Voltage: 208/230-1-60 V-Ph-Hz Unit Voltage: 208-1-60 V-Ph-Hz Fan Motor FLA: 0.50 Amps Motor HP: 1/3 HP MCA: 13.4 Amps Motor FLA: 2.9 Amps Max Fuse: 20 Amps Operating Range Min: 197 V Accessory Electric Heater Data Operating Range Max: 253 V EH Part Number: KFFEH8401NO3 Compressor RLA: 10.3 Amps Electric Heater kW: 2.3 kW Compressor LRA: 45.7 Amps For 2 wire operation (single circuit): Heater Amps: 10.7 Amps Heater + Motor MCA: 17 Amps Heater + Motor MOCP: 20 Amps Accessory Voltage: 208-1-60 V-Ph-Hz The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 UNIT DATA r oyc J VI I I GENERAL NOTES 1. DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE AND ROOFTOP ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK. 2. MECHANICAL SCOPE OF WORK BOUNDED BY BUILDING EXTERIOR WALLS AND ROOF, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PARALLEL AND PERPENDICULAR TO BUILDING COLUMN LINES. 3. THE NEW SPLIT SYSTEMS ARE REPLACING THE SAME TYPE AND CAPACITY SPLIT SYSTEMS IN THE SAME LOCATIONS, UTILIZING EXISTING POWER SUPPLY AND DUCTWORK. 4. NEW OUTDOOR HEAT PUMPS ARE SAME WEIGHT AS EXISTING. Acoustic Summary For 1.5T SS HP-SEER2 'roject: Sunrise Edmonds-1.5T SS HP 05/15/202, 3repared By: Outdoor Unit Parameters: Unit Model: Unit Size: Variations: 25SCA 1.5 Tons (Size 18) Standard Octave Band Center Frequency, Hz 125 250 500 1 k 2k 4k 8k dBA Sound Power,dB 70.2 66.4 65.1 67.4 62.8 58.2 52.5 A -Weighted Sound Power, dBA 71.0 Indoor Coil Parameters: Unit Model: Unit Size: Cabinet Width: FJ4D 18,000 Btuh (Size 18) TXV/ 14 Inches Cabinet Octave Band Center Frequency, Hz 63 1 125 1 250 1 500 1 1 k I 2k 1 4k Sound Power,dB 1 70.8 1 66.8 1 62.8 1 59.8 1 57.8 1 55.8 1 51.8 The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 r oyc v vi I I y A •. QFC45976 FO .•' �� ��,osoalloaoNo���B- 6 23 EXPIRES: 10/25/24 RECEIVED Aug 11 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT MOm2 EQUIPMENT SCHEDULES & DATA SHEETS PROJECT NO. 020-078B COPYRIGHT 2023 PINEHURST ENGINEERING, PLLC 0 4' 8' 16' I SCALE: 1/8" = V-0" 8/6/23 Certified Drawing For 1.5T SS HP-SEER2; Project: Sunrise Edmonds-1.5T SS HP 05/15/2023 Prepared By: Outdoor Model Unit Model: Unit Size: Voltage: SEER: PartNumber: A AIR DISCHARGE FIELD POWERCONN. Y!B"ftt.2I ROSE rII .,I AIR IN- 1H 118"1�28.6F KNOCKOUT FIELD CONTROL S PPLt CONK. O TIS't 22.2) HOLE .5) 0318.109Lj K LIOUIO LINE CONN. 3 191,0) IBT.9t I H - F•- Y so --'� "jT OC,APOR LINE CDNN.I 1 131tfi• i� 116.1) 11 / j" G j- NOTES: X SO. t 1, ALLOW 24' I609.6) CLEARANCE TO SERVICE SIDE OF UNIT, 4V (1218.2)ABOVE UNIT. 2 CENTER OF GRAVITY 2 1311i 6" (162.4)ON ONE SIDE, 12" (364.8) ON REMAINING SDI, AND 24" (609.6) BETWEEN 1 T1. I1 UNITS FOR PROPER AIRFLOW. 1 SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER 25SCA 1.5 Tons (Size 18) 208/230-1-60 V-Ph-Hz 15 25SCA518AO03 Shipping Dimensions and Weights Outdoor Unit Height 33.94 in Width 34.25 in Length 34.25 in Operating Weight 140.lb Shipping Weight i170. Ib Dimensions A B C D E F G H I J K 31.19 in 28.69 in 0.63 in 6.56 in 24.70 in 9.13 ini 1.13 ini 3.81 in 14.75 in 16.25 in 13.50 in The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at ***.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 Page 7 of 11 Certified Drawing For 1.5T SS HP-SEER2. Project: Sunrise Edmonds-1.5T SS HP 05/15/2023 Prepared By: NOTES: I, CONDENSATE PAN DRAIN CAN NOT SHOWN FOR CLARITY, 2. ALL DIMENSIONS ARE IN 'INCHES" UNLESS NOTED. 112' TYP.► i18" TYP./ Indoor Coil Unit Model: Unit Size: Voltage: PartNumber: PRIMARY ORA SECONDARY DRAIN- HORIZ, LEFT (AS SHIPPED) PRIMARY DRAI SECONDARY DRAI 113116' TYP. t 1 114' 1511 r" TrP.11 - 1518' 2 718' 2 9YIS" TYP, (2 PLACES)► FJ4D 18,000 Btuh (Size 18) 208-1-60 V-Ph-Hz FJ4DNXA18L00 SLOPE COIL 1116' TYP. 'IIFL: 12 PLACES)) I' TYP. l2 PLACES)i AIRFLOW + 1116" iYP. PLACES)+ PRIMARY DRAI SECONDARY DRAIN 5116, TYP.1 SECONDARY DRAI ® PRIMARY DRAINJ' �2 118" El' 1, I � 1116' TYP. IN"II L 2 9116" l2 PLACES)' r U PLACESII 113116' - i 114 TYP.1 UPFLOW DOWNFLOW (AS SHIPPED) (FIELD CONVERTED) 1 ! 2'IV 1114" TYP.2) 118' F TYP.1 HORIZ. RIGHT (FIELD CONVERTED) The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at ***.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 Page 9 of 11 Certified Drawing For 1.5T SS HP-SEER2; Project: Sunrise Edmonds-1.5T SS HP 05/15/2023 Prepared By: UNIT CONNECTION SIZES SUCTION: 118 6 111 - 5/8' I.D. SWEAT 030 6 036 - 3/�' I.D. 5.EAT 042 THRU 060 - 718" I.D. SWEAT LIQUID: 3/8' I.D. SWEAT CONDENSATE: 3/4' FPT 8 5/t6" C -DISCONNECT OR CIRCUIT BREAKER - LOCATION LOWER, CONTROL, 6 ELECTRIC HEATER ACCESS PANEL PANELACCESS 2 5l8' INEL- IDUID LINE CONNECTION PANEL SUCTION LINE CONNECTION 0 10 6 3f16" FILTER ACCESS OPENING PANEL D INLET AIR FRONT VIEW SHOWN WITH "A' COIL DETAILS CONNECTION LOCATIONS FOR UPFLOW OR HORI2. AP LIC A T T:•.t Indoor Coil I F NOTE: 1. SERIES DESIGNATION IS THE 14TH POSITION OF UNIT PRODUCT NUMBER I. ALL DIMENSIONS ARE IN "INCHES' UNLESS NOTED. 2118-- 2' DIA. K.O.'S FOR RICH VOLTAGE POWER WIRING T/8"DIA. N.O. 1 718" FOR LOW VOLTAGE CONTROL WIRING ALTERNATE 7!8'DIA. N.O. TOP VIEW 1 15/16' FOR LOw VOLTAGE 1 3l8' CONTROL WIRING INLET AIR A Unit Model: FJ4D Unit Size: 18,000 Btuh (Size 18) Voltage: 208-1-60 V-Ph-Hz Cabinet Insulation: TXV/ 14 Inches Cabinet PartNumber: FJ4DNXA18L00 SLOPE COIL DETAILS CONNECTION LOCATIONS SHOWN FON UPFLOW ON HONII. LEFT APPLICATIONS ACCESS PANEL CONFIG, FOR SLOPE COILS DOWNFLOW OR NORIZ. RIGHT APPLICATIONS AND "A" COILS DOWNFLOW APPLICATIONS tau iiHAY NOTE: ALLOW Zt' FROM FRONT FOR SERVICE 22 t116' D 3116" 1' OUTLET AIR r 31 4" --ALTERNATE 7/81,1 3E132".2'DIA. K.O.'S NOTE: MODULAR FOR HIGH VOLTAGE UNITS WILL HAVE POWER WIRING A TWO-PIECE OPPOSITE SIDE CABINET OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING (SLOPE COIL UNITS OPEN) t tJ2' I• � I � i I FOR t9' I NODJLAR UNITS L - - - - - OPENING 19 13/16" 2 10' RIGHT SIDE VIEW INLET AIR Dimensions and Weights Indoor Coil Height 42.69 in Width 14.31 in Length 22.06 in Shipping Weight 120. lb Dimensions A B C D E F G H J 42.69 ini 14.31 ini 12.44 in 1 12.31 in 1 18.13 in 1 18.63 in I --1 12.00 in The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at ***.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 Page 8 of 11 25SCA5 Comfort" Series Single -Stage Air Conditioner i with Fulron( Refrigerant 1-1/2 To 5 Tons Turn to the experts 11 Product Data �1ll,I,I.,I,�l9RI1I��I�1��� lijjII[)�-IIyI lll4ji I�:i14F�1�1�1� II UI anti ���llf �{� I' Illilja�ll lillllll�'N y � R!I 'I�l9�lUlllll� 01 This Trait has been desipned utilizing Carrier's non-ozme depleting Ptron$ refrigerant Heat pumps with Pull refrigerant provide a coliecticu of features unmatched by any other family of equupmenr. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHM directory (vmr r.ahridirecto--y-org) 6or the most up--to-date ratings Labormation Industry leading Features r Benefits Efficiency 14-3-1S2SEER" r 11.0-12.5EER217.5-9.1HSPF2 (depending on unit sine and indoor combination installed) Micratube tecUnology refrigeration system • Indoor air quality accessories mmilable Sound Sound levels as low as 69 dBA with accessory sound blanket Comfort System supports proer7a71 m ble or suaudard thermostat controls Reliability • Non -ozone depleting PuromM refrigerant Scroll compressor Internal pressure relief valve • Internal thermal overload • Loss of charge switch Filter drier Balanced refrigeration system for Tylaslilum relic-baity Durability WeatherA> lil Protection Package: Satid, durable sheet metal consmicaon • Dense nire coil guard Applications Lang -line - up to 250 feet (76.20 m) tote[ equivalent Ll up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft- (24.38 m) evaporator above condenser (See LrnnghnA Guide for mare information-) Lear ambient tooling (dawn to O■F,1-17.8'C) with approved Low ambient accessory kits Residential Carrier Products Bldr 1.37 Page 10 of 11 UNIT DATA SUE3JE'IT TO CHANGE WITHOUT NOTICE o C F LLJ C L U) CD M J C!D 00 M CV F "T Q 2!= C �O C/� 0 cV C Z 0 c� G O L Lo 00 w Q oO U UJ CJ . LJJ CV J - Cn C ;E:i p� W LLJ U ` IL�~ 3 O m a� Lo00 p> o Lo Z 7 [1? � Wn� •9� A •. % 45976 FO .•' �� • ISTER•.. �. O ��Opss�ONAL ENGp _ 6 23 ooc7oc P 8 EXPIRES: 10/25/24 STANDARD FEATURES ■ Multi -tap ECM (electronic commutating motor) motors - all sizes ■ Integrated motor controls, with 90-sec off TDIR function, have replaced integrated circuit board • Five available speed tags to meet a wide range of applications ■ Large, grooved tube, louvered fin coils O N Efficient, quiet, time -tested bknvrer housings and diffusers ^ 1 • Sturdy, drainable condensate pans �. ■ Cabinet construction features innovations designed to prevent cabinet sweating - Tested for condensate disposal in much tougher conditions than W Air Conditioning and Refrigeration Institute requirements ■ Super -thick R-4.2 insulation with vapor barrier • Pre -painted galvanized steel cabinet (taupe metallic) W ■ Cabinet air leakage of less than 2% at 0-5 in.W .C. and cabinet air O leakage less than 1.4% at 0.5 in- W.C. whlen tested in accordance with ASHiRAE 193 standard - Instal lation-flexible, multipoise units ■ Horizontal hanging provisions on cabinet W ■ No tools required to access fitter • Newly improved fitter rack area filter door insulation W W V 1 added for improved air seal r vul O ro11 1 'M MWNI I■dWOn ■ ,K,,,�ei■r„ Factory -installed heater packages available on select �YN models (5-through 15 kW) 1 dva■M�"hd4m.I 3- through 30-kW accessory heaters - field installed v � or�DNy - Factory -supplied power plug T 1 ^ O ■ Easy plug-in provisions for heater installation H • Entry options for high and low voltage wiring hook-up J - Leak -preventing sweat connections O N••j U ' Thermostatic expansion valve, TXV, on sill sizes .juLdir. O ■ Designed for manufactured housing applications - LIMITED WARRANTY* P.0 ArmorT13C 10 year parts to original purchaser upon timely registration, !�I otherwise 5 years 'For resklentlal appfle0ons. see warrdrrty for tuE detalls. ISSUE: Trrs doct mrr~ aws) not mnlain techrl= data cortrulled by tlNe EAR or )TAR. Residential Carrier Products Bldr 1.37 Page 11 of 11 RECEIVED Aug 11 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT MOm3 EQUIPMENT DATA SHEETS PROJECT NO. 020-078B COPYRIGHT 2023 PINEHURST ENGINEERING, PLLC 0 4' 8' 16' I SCALE: 1/8" = V-0" 8/6/23 a COPYRIGHT 2023 PINEHURST ENGINEERING, PLLC TN�ROOF PLAN -MECHANICAL SCALE: 1/8" = 1'-0° / / _Zsy GENERAL NOTES 1. DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE AND ROOFTOP ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK. 2. MECHANICAL SCOPE OF WORK BOUNDED BY BUILDING EXTERIOR WALLS AND ROOF, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PARALLEL AND PERPENDICULAR TO BUILDING COLUMN LINES. 3. THE NEW SPLIT SYSTEM UNITS ARE REPLACING THE SAME TYPE AND CAPACITY SPLIT SYSTEM IN THE SAME LOCATION, UTILIZING EXISTING DUCTWORK AND POWER SUPPLY. PLAN NOTES 01 STAGING OF EQUIPMENT AND CRANE LOCATIONS TO BE COORDINATED AND APPROVED PRIOR TO CONSTRUCTION. O2 NEW UNIT SHALL BE INSTALLED IN SAME LOCATION AS EXISTING O3 EXISTING ROOFTOP HVAC EQUIPMENT NOT IN SCOPE OF WORK (EXISTING TO REMAIN). ® NEW OHP-222 & OHP-313 REPLACEMENT 1.5-TON UNITS ARE THE SAME TYPE, WEIGHT AND OUTPUT CAPACITY AS EXISTING. NO NEW ROOF PENETRATIONS ARE REQUIRED FOR THIS WORK. RE -USE THE EXISTING ELECTRICAL DISCONNECT SWITCHES AS APPLICABLE. RE -USE EXISTING CONTROL WIRING. 0 4' 8' 16' SCALE: 1/8" = 1'-0" 8/6/23 m CN co U) 0 u- 75 0 U w z w _U J 6 23 3