Loading...
REVIEWED BLD-BLD2022-0616+Structural_Calculations+5.10.2022_3.08.18_PM+2860459BLD2022-0616 RECEIVED May 11 2022 Structural Design Associates CITY OF EDMONDS 3006 Rucker Ave. DEVELOPMENTSERVICES DEPARTMENTMENT Everett, WA 98201-3774 Phone: (425) 339-0293 Email: admin@sdaeverett.com REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT STRUCTURAL CALCULATIONS LATERAL, GRAVITY, & FONDATION SFR RETROFIT SDA Job # 9508 APR 15 2022 KUNKEL RESIDENCE 752 WALNUT ST EDMONDS, WA 98020 April 14, 2022 KUNKEL RESIDENCE I April 14, 2022 I SDA Job # 9508 Scope of Work: LATERAL, GRAVITY, & FONDATION SFR RETROFIT Site Address: 752 WALNUT ST EDMONDS, WA 98020 Number of Stories: 2 Engineer: JIB Reviewed by: CCC Risk Category: II BLDGS EXCEPT I, III, & IV Construction Type: LOW RISE - RESIDENTIAL Roof Level Loading: Roofing Composition 3.0 Sheathing 15/32" Plywood 1.5 z 0 Insulation Roll/Batt 3.0 w Ceiling 5/8" GWB 2.8 a w Framing Trusses 2.2 JMiscellaneous fixtures, mechanical, electrical, partitions etc. 2.5 LIVE LOAD: 20.0 psf TOTAL DEAD LOAD: 15.0 psf 25.0 psf WALL DEAD LOAD: Level Loading: 10.0 sf ROOF SNOW LOAD: 2nd Floor Floor Covering Carpet/Hardwood/Tile 3.3 z Sheathing 3/4" Plywood 2.3 1 0 Ceiling 1/2" GWB 2.2 °o w Joists 2x10 2.8 E: U) Beams 0.0 p J N Q Miscellaneous fixtures, mechanical, electrical, partitions etc. 1.4 WALL DEAD LOAD11 10.0 sf TOTAL DEAD LOAD: 12.0 psf Level Loading: FLOOR LIVE LOAD: 15.0 psf Grade Floor Covering Sheathing Ceiling Joists Beams Miscellaneous WALL DEAD LOAD TOTAL DEAD LOAD: 0.0 sf Level Loading: FLOOR LIVE LOAD: NA Floor Covering Sheathing Ceiling Joists Beams Miscellaneous NA WALL DEAD LOAD I TOTAL DEAD LOAD: 0.0 psf FLOOR LIVE LOAD: Soil Bearing Capacity: 1500 psf 18 in Frost Depth: KUNKEL RESIDENCE I April 14, 2022 SDA Job # 9508 Type of construction: I LOW RISE -RESIDENTIAL Location: 752 WALNUT ST Applicable Building Codes: 2018 IBC, ASCE 7-16 EDMONDS, WA 98020 Work performed : LATERAL, GRAVITY, & FONDATION SFR RETROFIT WIND DESIGN: Ps = APs30Kzt Enclosure Classification: Exposure : ENCLOSED - SIMPLE DIAPHRAGM PER ASCE 7-16, 26.2 B Wind Exposure Category as set forth in 2018 IBC, Section 1609.4 Wind Speed = 110 MPH Basic Wind Speed as used in ASCE 7-16, Figure 26.5-1(A-D) VASD = 86 MPH Allowable Stress Design Wind Speed ' = 0.89 Adjustment factor for building height and exposure from Figure28.5-1 of ASCE 7-16 KZT = 1.33 Adjustment factor for increased wind speed due to a hill or escarpment Roof slope: Front/Rear tan-1 ( rise run 4 / 12 ) = 18.4 degrees Number of floors: Left/Right tan-1 ( 4 / 12 ) = 18.4 degrees 20 ft Mean Elevation Average uplift (F/R)= -16.6 psf Based on wind zones'G' and'H' p Average uplift (R/L)= -16.6 sf Based on wind zones'G' and'H' v O End zone of wall End zone of roof Front/Rear Left/Right Front/Rear Left/Right '530= A = 25.8 psf 25.8 psf B = -7.3 psf -7.3 psf PS= 30.7 psf 30.7 psf -8.7 psf -8.7 psf ` Interior zone of wall Interior zone of roof Front/Rear s CO) Front/Rear 'S30= C = 17.2 psf Left/Right Left/Right 17.2 psf D = -4.1 psf -4.1 psf - PS= 20.4 psf 20.4 psf -4.9 psf -4.9 psf (A] Transverse FRONT/REAR (SOUTH/FRONT) ZONES FV Roof = WIND ZONE A B C D AVE. HEIGHT 50 32 154 112 AVE. WIDTH 1 1 1 1 Ps 30.68 0.00 20.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SUBTOTAL 1534 0 3142 0 0 0 0 0 0 0 0 0 TOTAL i5,568lb_s Minimum net pressure controls. The calculated pressure is less than the minimum net pressure, equal to 16 sf applied over the entire area. ASCE 7-10 27.1.5 ZV 2nd Floor = WIND ZONE A C AVE. HEIGHT 65 260 AVE. WIDTH 1 1 Ps 30.68 20.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SUBTOTAL 1994 5304 0 0 0 0 0 0 0 0 0 0 TOTAL 17,298lbs FV Grade = WIND ZONE AVE. HEIGHT AVE. WIDTH Ps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SUBTOTAL 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0lbs -------------------------------------- FV NA = WIND ZONE AVE. HEIGHT AVE. VVUTFI-- Ps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SUBTOTAL 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 10lbs KUNKEL RESIDENCE I April 14, 2022 SDA Job# 9508 LEFT/RIGHT (EASTMEST) ZONES IV Roof = WIND ZONE A B C D AVE. HEIGHT 72 46 245 186 AVE. WIDTH 1 1 1 1 Ps 30.68 0.00 20.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SUBTOTAL 2209 0 4998 0 0 0 0 0 0 0 0 0 TOTAL 18,784 lbs Minimum net pressure controls. The calculated pressure is less than the minimum net pressure, equal to 16 sf applied over the entire area. ASCE 7-10 27.1.5 FV 2nd Floor = WIND ZONE A C AVE. HEIGHT 101 396 AVE. WIDTH 1 1 Ps 30.68 20.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SUBTOTAL 3098 8078 0 0 0 0 0 0 0 0 0 0 TOTAL 111,177lbs 1V Grade = WIND ZONE AVE. WIDTH Ps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SUBTOTAL 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL :0lbs -------------------------------------- ZV NA = WIND ZONE AVE. HEIGHT AVE. WIDTH Ps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SUBTOTAL 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL :0lbs -------------------------------------- SEISMIC LOAD p CALCS (ASCE7-16 612.3.4): Roof Level Calculations Plate Height: 7.75 ft Tributary Area: 1.0 Total length of Shearwall in Shortest Line: 6.50 ft Total Area: 2.0 Length of Shortest Segment within Shear Line: 6.50 ft Length of Longest Segment in Shear Line: 6.50 ft p = 1.30 ASCE 7-16 12.3.4.2 2nd Floor Level Calculations Plate Height: 7.75 ft Tributary Area: 1.0 Total length of Shearwall in Shortest Line: 1.00 ft Total Area: 2.0 Length of Shortest Shearwall within Shear Line: 1.00 ft Length of Longest Wall in Shear Line: 1.00 ft p = 1.30 ASCE 7-16 12.3.4.2 Grade Level Calculations Plate Height: Tributary Area: 1.0 Total length of Shearwall in Shortest Line: Total Area: 2.0 Length of Shortest Shearwall within Shear Line: Length of Longest Wall in Shear Line: p = NA NA Level Calculations Plate Height: Tributary Area: 1.0 Total length of Shearwall in Shortest Line: Total Area: 2.0 Length of Shortest Shearwall within Shear Line: Length of Longest Wall in Shear Line: p = NA KUNKEL RESIDENCE I April 14, 2022 1 SDA Job# 9508 1 3 SEISMIC LOAD: (ASCE7-16 §12.8) httos://hazards.atcounci1.org/ Flexiable Diaph.? YES V=CsW Irregularities? NO SITE RESPONSE ANALYSIS REQUIREMENT 111.4.71 C SDS/(R/IQ) Risk Category = II Risk Category DESIGN WITH SEISMICALLY ISOLATED STRUCTURE? NO CS MIN_CASE2=0.SS,/(R/le) p = 1.30 Redundancy DESIGN STRUCTURE WITH DAMPING SYSTEM? NO CS MIN CASEI=0.044SDSle>0.011 Site Class = D - DEFAULT C: IE = 1 1.5.1) NOT REQUIRED: 11.4.8.E.2, Cs MODIFIED AS REQUIRED BY MAx=SDi/(T(R/le) (Table EXCEPTION T<TL, CS=SDi/R(R/le) h n=1 20 1 Structural Height T>TL, Cs=SD,TL/T2(R/le) E=Csp §11.4.4 Ss = 128.4% TYPE: (T12.2-1) Ta (s) R no Cd Cs E SMs=F.Ss = 154.1 % §11.4.4 Fa = 1.20 1) SDS=2/3SMS - 102.7% §11.4.4 S1 = 45.2% 2) SDS'=SDS = 102.7% §12.8.1.3 Fv = 1.95 3) SMi=F�Si = 88.3% §11.4.5 SDC = D 4) SDJ=2/3SM1 = 58.9% §11.4.5 TL - 6 s Ts=SD1/SDS = 57.3% §11.4.6 W (ROOF) = W (FLOOR) = W (WALL) = Roof Level Diaphragm Loading: A15 - WSW 1 0.19 1 6.50 2.50 4.00 0.158 0.205 G6 - TF 0.19 1.50 1.50 1.50 0.685 0.890 LENGTH WIDTH COEFF LOAD TOTAL 2363 1 1.1 15.0 38281 1.0 15.0 0 1.0 15.0 0 1.0 15.0 0 1.0 15.0 0 Area = 2363 Sub -Total= 38281 Ih LENGTH WIDTH LOAD TOTAL 12.0 0 12.0 0 12.0 0 12.0 0 12.0 0 Area = 0 Sub -Total= Ih NUMBER LENGTH TRIB. HT. LOAD TOTAL 1 188 3.875 10.0 7285 10.0 0 10.0 0 Area = 729 Sub -Total= 7285 TOTAL = 45566 lb 2nd Floor Level Diaphragm Loading: W (ROOF)_ W (FLOOR) = W (WALL) = LENGTH WIDTH COEFF LOAD TOTAL 1.0 15.0 0 1.0 15.0 0 1.0 15.0 0 1.0 15.0 0 1.0 15.0 0 Area = 0 Sub -Total= Ih LENGTH WIDTH LOAD TOTAL 1951 1 12.0 23412 12.0 0 12.0 0 12.0 0 12.0 0 Area = 1951 Sub -Total= 23412 Ih NUMBER LENGTH TRIB. HT. LOAD TOTAL 1 196 8.5 10.0 16660 10.0 0 10.0 0 Area = 1666 Sub -Total= 16660 TOTAL = 40072 lb KUNKEL RESIDENCE I April 14, 2022 1 SDA Job# 9508 1 4 SEISMIC DISTRIBUTION FOR: A15 - WSW, R=6.5 IIE 2) EV (ROOF) = EV (1 ST FLOOR) = EV()= EV()= TOTAL = EV (ROOF) = EV (1 ST FLOOR) = EV()= EV()= TOTAL = FV EV x p height FV x height 7201lb 9361lb 20 187220lb 6333lb 8232lb 8.33 68576lb 135331b 175931b SEISMIC DISTRIBUTION FOR: G6 - TF, R=1.5 255796 Ib FV FV x p height FV x height 31203lb 40564lb 20 811286lb 27441lb 35674lb 8.33 297162lb 586451b 762381b 1108448 lb UNFACTORED LOAD SUMMARY: REDISTRIBUTE: E EV x height x FV TOTAL = FV x height TOTAL 12877 lb 4716 lb REDISTRIBUTE: E ( ) EV x height x FV TOTAL = FV x height TOTAL 55800 lb 20438 lb WIND SEISMIC LEVEL (Ft-Rr) (Lt-Rr) A15 - WSW G6 - TF EV (Roof) = 5568 Ibs 8784 Ibs 12877 Ibs 55800 lb FV (2nd Floor) = 7298 Ibs 11177 Ibs 4716 Ibs 20438 lb NOT APPLICABLE NOT APPLICABLE TOTAL BASE SHEAR= 12866 Ibs 19961 Ibs 17593 Ibs 76238 lb KUNKEL RESIDENCE I April 14, 2022 1 SDA Job# 9508 IRREGULARITY: Increase in force due to irregularities for seismic design categories D-F (per ASCE7-16, §12.3.3.4): No • No seismic load change Affected Levels: Out -of -plane offset with discontinuity, including out -of -plane offset of at least one vertical elements (T12.3-1, Type 4) Yes • Seismic x 00 for diaphragm loading Affected Levels: One or two-family dwelling of light frame construction: Yes • 00=1.0 (§12.10.1.1) — no = 1.00 FLEXIBLE DIAPHRAGM DESIGN (ASD) IV (Roof) _ % of load transfer = 80% (Percentage of load transferred through diaphragm) Total diaphragm length = 32.3 ft Sub -diaphragm length = 32.3 ft 0.6 x EV (Roof) = 5,270 IbS FACTORED WIND (LEFT -RIGHT) ---> Location @ 253 PLF x S.G. = 0 Diaphragm width = 14.0 ft 0.7 x FV (Roof) = 6,934 IbS FACTORED SEISMIC / rho ---> Location @ 240 PLF x S.G. = 3 Aspect Ratio = 2.3092857 _ ASDxEV(FLOOR) v [5271 Ibs , 6934 Ibs] = [WIND=203 PLF, SEISMIC=267 PLF] `Seismic Governs! (2)(width)(S.G.) 2 x 14 ft. x 0.93 2015 SDPWS T4.2A & T4.2C 'NOTE: SEISMIC MAY GOVERN OVER WIND DUE TO HIGHER WIND CAPACITY USE: 15/32" SHEATHING WITH 2x HEM -FIR FRAMING; FASTEN AT PANEL EDGES WITH 8d @ 6" O/C EV (2nd Floor) = % of load transfer = 100% (Percentage of load transferred through diaphragm) Total diaphragm length = 26.0 ft Sub -diaphragm length = 26.0 ft 0.6 x EV (2nd Floor) = 6,706 IbS FACTORED WIND (LEFT -RIGHT) ---> Location @ 253 PLF x S.G. = 0 Diaphragm width = 21.0 ft 0.7 x EV (2nd Floor) = 2,540 IbS FACTORED SEISMIC / rho ---> Location @ 240 PLF x S.G. = 0 Aspect Ratio = 1.2380952 ASDxEV(FLOOR) v = _ [6707 Ibs , 2540 Ibs] _ [WIND=172 PLF, SEISMIC=66 PLF] Wind Governs! (2)(width)(S.G.) 2 x 21 ft. x 0.93 2015 SDPWS T4.2A & T4.2C 'NOTE: SEISMIC MAY GOVERN OVER WIND DUE TO HIGHER WIND CAPACITY USE: 3/4" SHEATHING WITH 2x HEM -FIR FRAMING; FASTEN AT PANEL EDGES WITH 8d @ 6" O/C KUNKEL RESIDENCE I April 14, 2022 1 SDA Job# 9508 1 6 CHORD DESIGN: EV (Roof) = Sub -diaphragm length = 32.3 ft Total -diaphragm length = 32.3 ft Design Load (critical case) = 213 PLF Sub -diaphragm width = 14.0 ft M *EV(unit shear) x (diaphragm length) 214 PLF x 32.33 . T = ft. = 8 = 8 = 861 Ibs *SEE DIAPHRAGM DESIGN FOR EV(unit Top Plate Size: 2x6 Species/Grade: shear) HF #2 Area =1 8.25 in Ft = 525 psi Load duration (CD) =1 1.60 Tallowable = Area x CD x Ft = 6,930 Ibs Since T allowable is greater than T applied, OK. SHEAR CAPACITY OF 10d COMMON NAIL = 102 Ibs RF1 the # OF NAILS PER 4FT. SPLICE = 163 Ibs = 6 NAILS 102 x Cd x p = 163 Ibs 2018 NDS USE: 2x6 HF #2 TOP PLATE w/ (8) 10d COMMON NAILS PER SPLICE EV (2nd Floor) = Sub -diaphragm length = 26.0 ft Total -diaphragm length = 26.0 ft Design Load (critical case) = 123 PLF Sub -diaphragm width = 21.0 ft T _ MB = *FV(unit shear) x (diaphragm length) _ 123 PLF x 26 ft. = 399 Ibs *SEE DIAPHRAGM DESIGN FOR EV(unit Top Plate Size: 2x6 Species/Grade: shear) HF #2 Area =1 8.25 in Ft = 525 psi Load duration (CD) =1 1.60 Tallowable = Area x CD x Ft = 6,930 Ibs Since T allowable is greater than T applied, OK. SHEAR CAPACITY OF 10d COMMON NAIL = 102 Ibs 102 x Cd x p = 163 Ibs 2018 NDS 399 Ibs USE: 2x6 HF #2 TOP PLATE w/ (8) 10d # OF NAILS PER 4FT. SPLICE = 163 Ibs = 3 NAILS COMMON NAILS PER SPLICE KUNKEL RESIDENCE I April 14, 2022 1 SDA Job# 9508 Lateral Calculation Key - for Shearwalls Only (See attached calcs for other lateral load resisting system designs) �P2 V V = Shear, plf H = Height of shearwall L = Length of shearwall P1 = Weight of shearwall and connected framing P2 = Weight of adjacent wall 1P 1 *T = V x H - 0.5P1 - P2 = Tension reaction to be resisted by holdown T� C C = V x H + 0.5P1 = Compression reaction *Holdown tension load supporting roof framing includes wind uplift from 'Zone G' &'Zone H' ASD Basic Load Combinations For calculation of tension and compression forces in compliance with ASCE 7-16 2.4.1 Tension Eauations (Uplift 7. 0.6D +0.6 W 8**. (0.6-0.14SDS)D+0.7Emh 10. 0.6D-0.7Ev+0.7Eh 10*. 0.6 D-0. 7 Ev+0. 7 E m h Compression Equations 5. D+0.6W 5** 0+0.14SDS)D+0.7Emh 6. D+0.75L+0.75(0.6W)+0.75S 6b**(1+0.105SDS)D+0.525Emh+0.75L+0.75S 8. D+0.7Ev+0.7Eh 8* D+0.7Ev+0.7Emh 9 D+0.525Ev+0.525Eh+0.75L+0.75S 9* D+0.525Ev+0.525Emh+0.75L+0.75S LRFD Basic Load Combinations (Where Applicable) For calculation of tension and compression forces in compliance with ASCE 7-16 2.3.1 Tension Equations (Uplift) 5. 0.9D+W 7. 0.9D-Ev+Eh 7*. 0.9D-Ev+Emh 7**. (0.9-0.2SDS)D+Emh Compression Equations 4. 1.2D+1.6W+L+0.5S 5**. (1+0.2SDS)D+Emh+L+0.2S 6. 1.2D+Ev+Eh+L+0.2S 6*. 1.2 D+ Ev+Emh+L+0.2 S Load Symbol Legend: D - Dead load L - Live load S - Snow load W - Wind load SDS - Design spectral response acceleration Eh - Effect of horizontal seismic forces Ev - Effect of vertical seismic forces Em - Effect of horizontal seismic forces, including overstrength Emh - Vertical seismic load effect Abbreviation Symbol Legend: HD - HOLDOWN Shear Wall Coefficient Legend: (see "SEGMENTED SHEAR WALL DESIGN" pages) WL FACTOR- Factor for increasing seismic capacity to wind load capacity per SDPWS-2015 T4.3A. ASPECT RATIO - Full -height segmented shear wall reduction factor per SDPWS-2015 4.3.3.4.1. Shear walls with similar stiffness per 4.3.4.2. TOTAL ADJ. LENGTH - Sumation of shear wall segments widths adjusted with aspect ratio (as required). S.G. - Specific Gravity Adjustment Factor for Hem -Fir Framing (may be increased to 1.0 for Douglas -Fir framing). ASD - Allowable Stress Design load combination factor. ALLOWED UNIT SHEAR - Unit shear capacity per SDPWS-2015 T4.3A. Shear values adjusted with FACTOR OF SAFETY per 4.3.3. WIND CAPACITY - Ultimate shear value calculated per: WL FACTOR x S.G. x UNFACTORED SHEAR CAPACITY/ (FACTOR OF SAFETY x ASD). SEISMIC CAPACITY - Ultimate shear value caulated per: S.G. x UNFACTORED SHEAR CAPACITY / (FACTOR OF SAFETYx ASD). KUNKEL RESIDENCE I April 14, 2022 SDA Job # 9508 8 ROOF -FRONT A15 - WSW I FTAO (SEE ATTACHED CALCS) Floor Info ROOF Floor Level, e.g. Roof, 4TH, 3RD, 2ND Lt-Rt Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX Sheathing type (T4.3A of SDPWS-2015) ROOF Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length 26.0 ft EV (ROOF) = 8784 lb 12877 lb EV () = 0 lb 0 lb EV () = 0 lb 0 lb EV () = 0 lb 0 lb E (Wind) = 8,784 lb E (Smc) = 12,877 lb ULT. V = 78 PLF ULT. V = 115 PLF 2,030 lb 2,987 lb ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 460 PLF / (2 x 0.6) = 499 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 460 PLF / (2 x 0.7) = 305 PLF Holdown Above: 1 NO FLOOR ABOVE ASD C. TOTAL = (floor above) + (this floor) = ASD T. TOTAL W/o 00 = (floor above) + (this floor) = Unfactored C. WL = 605 Ibs Unfactored T. WL = 1104 Ibs Unfactored C. EQ = 890 Ibs Unfactored T. EQ = 890 Ibs Unfactored C. DL = 1613 Ibs Unfactored C.LL/SL = 750 Ibs Tributary Area (ROOF) Tributary Area (ROOF) 13.8 tributary width 13.8 tributary area 59.5 total width 59.5 total area Tributary Area (2ND) Tributary Area (2ND) tributary width tributary area total width total area Tributary Area (NA) Z Tributary Area (NA) ID ? tributary width a tributary area total width 0total area o Tributary Area (NA) Tributary Area (NA) tributary width w tributary area total width Itotal area Height of Sheanwall = 7.8 ft Length of Sheanwall = 26.0 ft Aspect Ratio OK Weight of Shearwall = 10.0 Ibs Tributary width for dead load = 2.0 ft Length of adjoining wall = 2.0 ft R = 6.5 LRFD Holdown Design? No no = 2.5 Ductile Anchor Design? I No Block Shear Wall USE 1 Seismic controls shearwall design 0 Ibs + 855 Ibs = 855 Ibs Seismic controls -C3 (ASD eq. 8): 0 Ibs + -112 Ibs = -112 Ibs Seismic controls -T2 (ASD eq. 10): NO HOLDOWNS REQUIRED OK FOUNDATION / INTERIOR WALLS: OK CORNER STRAP: LSTA18 I ROOF -REAR I A15 - WSW IFTAO (SEE ATTHACED CALCS) Floor Info ROOF Floor Level, e.g. Roof, 4TH, 3RD, 2ND Lt-Rt Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX Sheathing type (T4.3A of SDPWS-2015) ROOF Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length 14.0 ft EV (ROOF) = 8784 lb 12877 lb EV () = 0 lb 0 lb EV () = 0 lb 0 lb EV () = 0 lb 0 lb E (Wind) = 8,784 lb E (Smc) = 12,877 lb ULT. V = 58 PLF ULT. V = 85 PLF t1"IZ ID -I,-IyU ID ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 460 PLF / (2 x 0.6) = 499 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 460 PLF / (2 x 0.7) = 305 PLF Holdown Above: 1 NO FLOOR ABOVE ASD C. TOTAL = (floor above) + (this floor) = ASD T. TOTAL w/o 00 = (floor above) + (this floor) = Unfactored C. WL = 449 Ibs Unfactored T. WL = 1871 Ibs Unfactored C. EQ = 659 Ibs Unfactored T. EQ = 659 Ibs Unfactored C. DL = 1980 Ibs Unfactored C.LL/SL = 2138 Ibs Tributary Area (ROOF) Tributary Area (ROOF) 5.5 tributary width tributary area Mtotal 59.5 total width area Tributary Area (2ND) Tributary Area (2ND) tributary width tributary area total width total area Tributary Area (NA) Z Tributary Area (NA) ? tributary width a tributary area total width 0total area o Tributary Area (NA) Tributary Area (NA) ztributary width w tributary area total width total area Height of Shearwall = 7.8 ft Length of Shearwall = 14.0 ft Aspect Ratio OK Weight of Shearwall = 10.0 Ibs Tributary width for dead load = 9.5 ft Length of adjoining wall = 2.0 ft R = 6.5 LRFD Holdown Design? No no = 2.5 Ductile Anchor Design? I No Block Shear Wall USE 11 Seismic controls shearwall design 0 Ibs + 746 Ibs = 746 Ibs Seismic controls -C3 (ASD eq. 8): 0 Ibs + -66 Ibs = -66 Ibs Wind controls -T1 (ASD eq. 7): NO HOLDOWNS REQUIRED OK FOUNDATION / INTERIOR WALLS: OK CORNER STRAP: LSTA18 KUNKEL RESIDENCE I April 14, 2022 SDA Job # 9508 9 ROOF - RIGHT A15 - WSW FTAO (SEE ATTHACED CALCS) Floor Info ROOF Floor Level, e.g. Roof, 4TH, 3RD, 2ND Ft-Rr Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX Sheathing type (T4.3A of SDPWS-2015) ROOF Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length 28.5 ft 24.8 ft EV (ROOF) = 5568 lb 12877 lb EV () = 0 lb 0 lb EV () = 0 lb 0 lb EV () = 0 lb 0 lb E (Wind) = 5,568 lb E (Smc) = 12,877 lb ULT. V = 52 PLF ULT. V = 121 PLF 1,489 lb 3,443 lb ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 460 PLF / (2 x 0.6) = 499 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 460 PLF / (2 x 0.7) = 305 PLF Holdown Above: 1 NO FLOOR ABOVE ASD C. TOTAL = (floor above) + (this floor) = ASD T. TOTAL w/o 00 = (floor above) + (this floor) = Unfactored C. WL = 405 Ibs Unfactored T. WL = 884 Ibs Unfactored C. EQ = 936 Ibs Unfactored T. EQ = 936 Ibs Unfactored C. DL = 1548 Ibs Unfactored C.LL/SL = 720 Ibs ROOF - LEFT Al - WSW Floor Info ROOF Floor Level, e.g. Roof, 4TH, 3RD, 2ND Ft-Rr Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX Sheathing type (T4.3A of SDPWS-2015) ROOF Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length 14.0 ft 1 13.0 ft 1 13.8 ft EV (ROOF) = 5568 lb 12877 lb EV () = 0 lb 0 lb EV () = 0 lb 0 lb EV () = 0 lb 0 lb 3 E (Wind) = 5,568 lb E (Smc) = 12,877 lb ULT. V = 68 PLF ULT. V = 158 PLF ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 460 PLF / (2 x 0.6) = 499 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 460 PLF / (2 x 0.7) = 305 PLF Holdown Above: 1 NO FLOOR ABOVE ASD C. TOTAL = (floor above) + (this floor) = ASD T. TOTAL w/o 00 = (floor above) + (this floor) = Unfactored C. WL = 529 Ibs Unfactored T. WL = 812 Ibs Unfactored C. EQ = 1225 Ibs Unfactored T. EQ = 1225 Ibs Unfactored C. DL = 914 Ibs Unfactored C.LL/SL = 425 Ibs Tributary Area (ROOF) Tributary Area (ROOF) 1.0 tributary width 1.0 tributary area 2.0 total width 2.0 total area Tributary Area (2ND) Tributary Area (2ND) tributary width tributary area total width total area Tributary Area (NA) Z Tributary Area (NA) ID ? tributary width a tributary area total width 0total area o Tributary Area (NA) Tributary Area (NA) tributary width w tributary area total width Itotal area Height of Shearwall = 7.8 ft Weight of Shearwall = 10.0 Ibs Length of Shearwall = 24.8 ft Tributary width for dead load = 2.0 ft Aspect Ratio OK Length of adjoining wall = 2.0 ft R = 6.5 LRFD Holdown Design? No no = 2.5 Ductile Anchor Design? No Block Shear Wall USE 1 Seismic controls shearwall design 0 Ibs + 878 Ibs = 878 Ibs Seismic controls -C3 (ASD eq. 8): 0 Ibs + -51 Ibs = -51 Ibs Seismic controls -T2 (ASD eq. 10): NO HOLDOWNS REQUIRED OK FOUNDATION / INTERIOR WALLS: OK CORNER STRAP: LSTA18 SEGMENTED WALL Tributary Area (ROOF) Tributary Area (ROOF) 1.0 tributary width 1.0 tributary area 2.0 total width 2.0 total area Tributary Area (2ND) Tributary Area (2ND) tributary width tributary area total width total area Tributary Area (NA) Z Tributary Area (NA) Q K tributary width a tributary area total width 0total area Tributary Area (NA) L Area (NA) 1zo tributary width wtributary area Ptotalarea total width Height of Shearwall = 7.8 ft Length of Shearwall = 13.0 ft Aspect Ratio OK Weight of Shearwall = 10.0 Ibs Tributary width for dead load = 2.0 ft Length of adjoining wall = 2.0 ft R = 6.5 LRFD Holdown Design? No no = 2.5 Ductile Anchor Design? I No Block Shear Wall USE 1 Seismic controls shearwall design 0 Ibs + 989 Ibs = 989 Ibs Seismic controls -C3 (ASD eq. 8): 0 Ibs + 440 Ibs = 440 Ibs Seismic controls -T2 (ASD eq. 10): NO HOLDOWNS REQUIRED OK FOUNDATION / INTERIOR WALLS: OK KUNKEL RESIDENCE I April 14, 2022 SDA Job # 9508 10 ROOF -MARRIAGE WALL A15 - WSW SEGMENTED WALL Floor Info ROOF Floor Level, e.g. Roof, 4TH, 3RD, 2ND Lt-Rt Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX Sheathing type (T4.3A of SDPWS-2015) ROOF Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length 7.0 ft EV (ROOF) = 8784 lb EV()= 0lb EV()= 0lb EV()= 0lb E (Wind) = 8,784 Ib ULT. V = 627 PLF 12877 lb 0 lb 0 lb 0 lb E (Smc) = 12,877 lb ULT. V = 920 PLF ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 1740 PLF / (2 x 0.6) = 1887 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 1740 PLF / (2 x 0.7) = 1155 PLF Holdown Above: NO FLOOR ABOVE ASD C. TOTAL = (floor above) + (this floor) = ASD T. TOTAL w/o DO = (floor above) + (this floor) = Unfactored C. WL = 4863 Ibs Unfactored T. WL = 5594 Ibs Unfactored C. EQ = 7128 Ibs Unfactored T. EQ = 7128 Ibs Unfactored C. DL = 1086 Ibs Unfactored C.LL/SL = 1100 Ibs Tributary Area (ROOF) Tributary Area (ROOF) 1.0 tributary width 1.0 tributary area 2.0 total width 2.0 total area Tributary Area (2ND) Tributary Area (2ND) tributary width tributary area total width total area Tributary Area (NA) z Tributary Area (NA) ID ? tributary width a tributary area total width 0total area o Tributary Area (NA) Tributary Area (NA) tributary width w tributary area total width Itotal area Height of Sheanwall = 7.8 ft Weight of Shearwall = 10.0 Ibs Length of Sheanwall = 7.0 ft Tributary width for dead load = 8.0 ft Aspect Ratio OK Length of adjoining wall = 2.0 ft R = 6.5 LRFD Holdown Design? No no = 2.5 Ductile Anchor Design? No Block Shear Wall USE 5 3x framing per IBC Seismic controls shearwall design 0 Ibs + 5146 Ibs = 5146 Ibs Seismic controls -C3 (ASD eq. 8): 0 Ibs + 4494 Ibs = 4494 Ibs Seismic controls -T2 (ASD eq. 10): I ROOF - REAR INTERIOR I A15 - WSW (SEGMENTED WALL Floor Info ROOF Floor Level, e.g. Roof, 4TH, 3RD, 2ND Lt-Rt Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX Sheathing type (T4.3A of SDPWS-2015) ROOF Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length 5.3 ft EV (ROOF) = 8784 lb EV()= 0lb EV()= 0lb EV()= 0lb E (Wind) = 8,784 lb ULT. V = 440 PLF 12877 lb 0 lb 0 lb 0 lb E (Smc) = 12,877 lb ULT. V = 646 PLF Z,341 ID 5,441 ID ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 1020 PLF / (2 x 0.6) = 1106 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 1020 PLF / (2 x 0.7) = 677 PLF Holdown Above: 1 NO FLOOR ABOVE ASD C. TOTAL = (floor above) + (this floor) = ASD T. TOTAL w/o 00 = (floor above) + (this floor) = Unfactored C. WL = 3413 Ibs Unfactored T. WL = 3568 Ibs Unfactored C. EQ = 5003 Ibs Unfactored T. EQ = 5003 Ibs Unfactored C. DL = 501 Ibs Unfactored C.LL/SL = 233 Ibs SIMPSON DESIGNED HOLDOWN: MST60 FOUNDATION / INTERIOR WALLS: HDU5-SDS2.5 Tributary Area (ROOF) Tributary Area (ROOF) 15.9 tributary width 15.9 tributary area 59.5 total width 59.5 total area Tributary Area (2ND) Tributary Area (2ND) tributary width tributary area total width total area Tributary Area (NA) z Tributary Area (NA) ? tributary width a tributary area total width 0total area o Tributary Area (NA) Tributary Area (NA) ztributary width w tributary area total width total area Height of Shearwall = 7.8 ft Length of Shearwall = 5.3 ft Aspect Ratio OK Weight of Shearwall = 10.0 Ibs Tributary width for dead load = 2.0 ft Length of adjoining wall = 2.0 ft R = 6.5 LRFD Holdown Design? No no = 2.5 Ductile Anchor Design? I No Block Shear Wall USE Seismic controls shearwall design 0 Ibs + 3575 Ibs = 3575 Ibs Seismic controls -C3 (ASD eq. 8): 0 Ibs + 3274 Ibs = 3274 Ibs Seismic controls -T2 (ASD eq. 10): SIMPSON DESIGNED HOLDOWN: MST60 FOUNDATION / INTERIOR WALLS: STHD14/RJ KUNKEL RESIDENCE I April 14, 2022 SDA Job # 9508 11 ROOF -TRELLIS G6 - TF -NA- Floor Info ROOF Floor Level, e.g. Roof, 4TH, 3RD, 2ND Ft-Rr Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) ROOF Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length 10.0 ft EV (ROOF) = 5568 lb 55800 lb EV () = 0 lb 0 lb EV () = 0 lb 0 lb EV () = 0 lb 0 lb E (Wind) = 5,568 lb E (Smc) = 55,800 lb ULT. V = 73 PLF ULT. V = 166 PLF Holdown Above: Tributary Area (ROOF) Tributary Area (ROOF) 7.8 tributary width 70.5 tributary area 59.5 total width 2363.0 total area Tributary Area (2ND) Tributary Area (2ND) tributary width tributary area total width total area Tributary Area (NA) Z Tributary Area (NA) ID ? tributary width a tributary area total width 0total area o Tributary Area (NA) Tributary Area (NA) tributary width w tributary area total width Itotal area I 2ND-REAR I A15 - WSW (SEGMENTED WALL Floor Info 2ND Floor Level, e.g. Roof, 4TH, 3RD, 2ND Ft-Rr Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX Sheathing type (T4.3A of SDPWS-2015) 2ND/FL Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length 10.0 ft EV (ROOF) = 5568 lb 12877 lb EV (2ND FLOOR) = 7298 lb 4716 lb EV () = 0 lb 0 lb EV () = 0 lb 0 lb 3 E (Wind) = 12,866 lb E (Smc) = 17,593 lb ULT. V = 119 PLF ULT. V = 163 PLF ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 460 PLF / (2 x 0.6) = 499 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 460 PLF / (2 x 0.7) = 305 PLF Holdown Above: 1 ROOF -REAR ASD C. TOTAL = (floor above) + (this floor) = ASD T. TOTAL w/o 00 = (floor above) + (this floor) = Unfactored C. WL = 1361 Ibs Unfactored T. WL = 2782 Ibs Unfactored C. EQ = 1905 Ibs Unfactored T. EQ = 1905 Ibs Unfactored C. DL = 2852 Ibs Unfactored C.LL/SL = 2138 Ibs R= 1.5 no Tributary Area (ROOF) Tributary Area (ROOF) 5.5 tributary width tributary area Mtotal total width area Tributary Area (2ND) Tributary Area (2ND) 5.5 tributary width 5.5 tributary area 59.5 total width 59.5 total area Tributary Area (NA) Z Tributary Area (NA) Q K tributary width a tributary area total width 0total area o Tributary Area (NA) Tributary Area (NA) z tributary width w tributary area �: total width Itotal area Height of Shearwall = 7.7 ft Length of Shearwall = 10.0 ft Aspect Ratio OK Weight of Shearwall = 10.0 Ibs Tributary width for dead load = 4.0 ft Length of adjoining wall = 2.0 ft R = 6.5 LRFD Holdown Design? No no = 2.5 Ductile Anchor Design? I No Block Shear Wall USE 1 Seismic controls shearwall design 746 Ibs + 997 Ibs = 1744 Ibs Seismic controls -C3 (ASD eq. 8): -442 Ibs + 474 Ibs = 32 Ibs Seismic controls -T2 (ASD eq. 10): NO HOLDOWNS REQUIRED OK FOUNDATION / INTERIOR WALLS: OK KUNKEL RESIDENCE I April 14, 2022 SDA Job # 9508 12 2ND - RIGHT A15 - WSW ISEGMENTED WALL Floor Info 2ND Floor Level, e.g. Roof, 4TH, 3RD, 2ND Ft-Rr Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX I Sheathing type (T4.3A of SDPWS-2015) 2ND/FL I Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length 3.7 ft 1 2.8 ft 1 8.0 ft FV (ROOF) = 5568 lb 128771b EV (2ND FLOOR) = 7298 lb 47161b EV 0 = 0 lb O lb FV 0 = 0 lb O lb E (Wind) = 12,866 lb E (Smc) = 17,593lb ULT. v = 478 PLF ULT. v = 653 PLF ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 1020 PLF I (2 x 0.6) = 1106 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 1020 PLF I (2 x 0.7) = 677 PLF Holdown Above: 1 ROOF - RIGHT ASD C. TOTAL = (floor above) + (this floor) = ASD T. TOTAL w/o DO = (floor above) + (this floor) = LRFD T. TOTAL w/ DO = (floor above) + (this floor) = Unfactored C. WL = 4063 Ibs Unfactored T. WL = 4542 Ibs Unfactored C. EQ = 5939 Ibs Unfactored T. EQ = 5939 Ibs Unfactored C. DL = 1888 Ibs Unfactored C.LL/SL = 720 Ibs Floor Info ROOF Floor Level, e.g. Roof, 4TH, 3RD, 2ND Ft-Rr Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX I Sheathing type (T4.3A of SDPWS-2015) 2ND/FL I Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length 11.3ft 1 2.8 ft FV (ROOF) = 5568 lb 128771b FV 0 = 0 lb O lb FV 0 = 0 lb O lb FV 0 = 0 lb O lb E (Wind) = 5,568 lb E (Smc) = 12,877lb ULT. v = 209 PLF ULT. v = 484 PLF ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 1020 PLF I (2 x 0.6) = 1106 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 1020 PLF I (2 x 0.7) = 677 PLF Holdown Above: ROOF - LEFT ASD C. TOTAL = (floor above) + (this floor) = ASD T. TOTAL w/o 00 = (floor above) + (this floor) = LRFD T. TOTAL w/ 00 = (floor above) + (this floor) = Unfactored C. WL = 2133 Ibs Unfactored T. WL = 2416 Ibs Unfactored C. EQ = 4932 Ibs Unfactored T. EQ = 4932 Ibs Unfactored C. DL = 1254 Ibs Unfactored C.LL/SL = 425 Ibs Tributary Area (ROOF) Tributary Area (ROOF) 1.0 tributary width 1.0 tributary area 2.0 total width 2.0 total area Tributary Area (2ND) Tributary Area (2ND) 1.0 tributary width 1.0 tributary area 2.0 total width 2.0 total area Tributary Area (NA) z Tributary Area (NA) z tributary width a tributary area ototal width total area o Tributary Area (NA) Tributary Area (NA) z tributary width w tributary area total width total area Height of Sheanaall = 7.7 ft Length of Sheanvall = 2.8 ft Aspect Ratio OK Weight of Shearwall = 10.0 Ibs Tributary width for dead load = 2.0 ft Length of adjoining wall = 2.0 ft R = 6.5 LRFD Holdown Design? Yes DO = 2.5 Ductile Anchor Design? I No Block Shear Wall USE 3 Seismic controls shearwall design 879 Ibs + 3550 Ibs = 4429 Ibs Seismic controls -C3 (ASD eq. 8): -50 Ibs + 3346 Ibs = 3297 Ibs Seismic controls -T2 (ASD eq. 10): 727 Ibs 9383 Ibs = 10110 Ibs Seismic 00 controls -T3 (LRFD eq. 7'): SIMPSON DESIGNED HOLDOWN: HDU4(THR000H FOUNDATION / INTERIOR WALLS: Tributary Area (ROOF) Tributary Area (ROOF) 1.0 tributary width 1.0 tributary area 2.0 total width 2.0 total area Tributary Area (2ND) Tributary Area (2ND) 1.0 tributary width 1.0 tributary area 2.0 total width 2.0 total area Tributary Area (NA) Z Tributary Area (NA) z tributary width a tributary area ototal width total area o Tributary Area (NA) Tributary Area (NA) z tributary width w tributary area total width total area Weight of Shearwall = 10.0 Ibs Tributary width for dead load = 2.0 ft Length of adjoining wall = 2.0 ft R = 6.5 LRFD Holdown Design? Yes no = 2.5 Ductile Anchor Design? I No Block Shear Wall USE Seismic controls shearwall design 989 Ibs + 2644 Ibs = 3633 Ibs Seismic controls -C3 (ASD eq. 8): 441 Ibs + 2440 Ibs = 2881 Ibs Seismic controls -T2 (ASD eq. 10): 1720 Ibs + 6893 Ibs = 8613 Ibs Seismic 00 controls -T3 (LRFD eq. 7'): SIMPSON DESIGNED HOLDOWN: HDU4 THROUGH FOUNDATION / INTERIOR WALLS: 11 Height of Sheanaall = 7.7 ft Length of Sheanaall = 2.8 ft Aspect Ratio OK KUNKEL RESIDENCE I April 14, 2022 SDA Job # 9508 13 2ND - MARRIAGE WALL A15 - WSW ISEGMENTED WALL Floor Info 2ND Floor Level, e.g. Roof, 4TH, 3RD, 2ND Lt-Rt Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX Sheathing type (T4.3A of SDPWS-2015) 2ND/FL I Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length 5.0 ft FV (ROOF) = 8784 lb 128771b EV (2ND FLOOR) = 11177 lb 47161b FV()= 0lb Olb FV()= 0lb Olb E (Wind) = 19,961 lb E (Smc) = 17,593lb ULT. v = 1996 PLF ULT. v = 1759 PLF ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 2660 PLF I (2 x 0.6) = 2886 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 2660 PLF I (2 x 0.7) = 1767 PLF Holdown Above: ROOF -MARRIAGE WALL ASD C. TOTAL = (floor above) + (this floor) _ ASD T. TOTAL W/o DO = (floor above) + (this floor) _ Tributary Area (ROOF) Tributary Area (ROOF) 1.0 tributary width 1.0 tributary area 2.0 total width 2.0 total area Tributary Area (2ND) Tributary Area (2ND) 1.0 tributary width 1.0 tributary area 2.0 total width 2.0 total area Tributary Area (NA) z Tributary Area (NA) z tributary width a tributary area ototal width total area o Tributary Area (NA) Tributary Area (NA) z tributary width w tributary area total width total area Height of Shearwall = 7.7 ft Length of Sheanvall = 5.0 ft Aspect Ratio OK Weight of Shearwall = 10.0 Ibs Tributary width for dead load = 2.0 ft Length of adjoining wall = 2.0 ft R = 6.5 LRFD Holdown Design? No no = 2.5 Ductile Anchor Design? I No A Block Shear Wall USE 7 3x framing per IBC Seismic controls shearwall design 5147 Ibs + 9499 Ibs = 14646 Ibs Seismic controls -C3 (ASD eq. 8): 4495 Ibs + 9227 Ibs = 13722 Ibs Seismic controls -T2 (ASD eq. 10): Unfactored C. WL = 20153 Ibs Unfactored T. WL = 20885 Ibs SIMPSON DESIGNED HOLDOWN: HDU14-SDS2.5 Unfactored C. EQ = 20606 Ibs Unfactored T. EQ = 20606 Ibs FOUNDATION / INTERIOR WALLS: HDU14-SD32.5 Unfactored C. DL = 1540 Ibs Unfactored C.LL/SL = 1100 Ibs 2ND - REAR INTERIOR i A15 - WSW iSEGMENTED WALL Floor Info 2ND Floor Level, e.g. Roof, 4TH, 3RD, 2ND Lt-Rt Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX I Sheathing type (T4.3A of SDPWS-2015) 2ND/FL I Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length 3.0 ft 1 3.0 ft FV (ROOF) = 8784 lb 128771b EV (2ND FLOOR) = 11177 lb 47161b FV()= 0lb Olb FV()= 0lb Olb 3 E (Wind) = 19,961 lb E (Smc) = 17,593lb ULT. v = 955 PLF ULT. v = 842 PLF ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 1330 PLF I (2 x 0.6) = 1443 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 1330 PLF I (2 x 0.7) = 883 PLF Holdown Above: ROOF - REAR INTERIOR ASD C. TOTAL = (floor above) + (this floor) = ASD T. TOTAL W/o DO = (floor above) + (this floor) = Unfactored C. WL = 10730 Ibs Unfactored T. WL = 10885 Ibs Unfactored C. EQ = 11452 Ibs Unfactored T. EQ = 11452 Ibs Unfactored C. DL = 1243 Ibs Unfactored C.LL/SL = 234 Ibs Tributary Area (ROOF) Tributary Area (ROOF) 15.9 tributary width 15.9 tributary area 59.5 total width 59.5 total area Tributary Area (2ND) Tributary Area (2ND) 15.9 tributary width 15.9 tributary area 59.5 total width 59.5 total area Tributary Area (NA) z Tributary Area (NA) ? tributary width a tributary area ototal width total area o Tributary Area (NA) Tributary Area (NA) z tributary width w tributary area total width total area Height of Sheanaall = 7.7 ft Length of Sheanaall = 3.0 ft Aspect Ratio OK Weight of Shearwall = 10.0 Ibs Tributary width for dead load = 11.3 ft Length of adjoining wall = 2.0 ft R = 6.5 LRFD Holdown Design? No no = 2.5 Ductile Anchor Design? I No A Block Shear Wall USE 4 3x framing per IBC Seismic controls shearwall design 3576 Ibs + 4620 Ibs = 8196 Ibs Seismic controls -C3 (ASD eq. 8): 3274 Ibs + 4176 Ibs = 7450 Ibs Seismic controls -T2 (ASD eq. 10): SIMPSON DESIGNED HOLDOWN: HDU11-SDS2.5 FOUNDATION / INTERIOR WALLS: HDU8-SD32.5 Project Information Code: 20181BC Date: 4/4/2022 Designer: Client: Project: SDAN9508 Wall Line: ROOF -FRONT L3(ft) Loilft) L2(ft) Lo2(ft) Lslft V(m "s L-110 ) Shear Wall Calculation Variables V 2987 Ibf Opening 1 Opening 2 Adj. Factor Method = 2bs/h L1 1.50 ft halA4.00 ha2 1.00 ft Wall Pier Aspect Ratio Adj. Face L2 11.58 ft hol ho2 4.00 ft Pl=h L1= 2.67 0.750 L3 2.90 ft hbl hb2 3.00 ft P2=hJL2= 0.35 N/A h_11 8.00 ft Lo1 Lo2 6.00 ft P3=hJL3= 1.38 N/A L-11 25.98 ft 1. Hold-down forces: H = Vh_,,/L..,, 920 lbf 6. Unit shear beside opening 2. Unit shear above +below opening vl = (V/L)(Ll+T1)/L1 = First opening: vat = vb1 = H/(hal+hbl) = 230 plf v2 = (V/L)(T2+L2+T3)/L2 = Second opening: vat = vb2 = H/(ha2+hb2) = 230 plf v3 = (V/L)(T4+L3)/L3 = Check vl*L1+v2*L2+v3*L3=V? 3. Total boundary force above + below openings First opening: 01 = val x (Lol) = 920 lbf 7. Resistance to corner forces Second opening: 02 = vat x (Lo2) = 1379 lbf Rl = v1*L1 = R2 = v2*L2 = 4. Corner forces R3 = v3*1_3 = F1 = 01(L1)/(L1+L2) = 105 lbf F2 = 01(L2)/(Ll+L2) = 814 lbf B. Difference corner force + resistance F3 = O2(L2)/(L2+L3) = 1103 lbf RI-F1 = F4 = O2(L3)/(L2+L3) = 276 lbf 1124243 = R3-F4 = S. Tributary length of openings T1 = (L1*Lol)/(Ll+L2) = 0.46 ft 9. Unit shear in corner zones T2 = (L2*Lol)/(Ll+L2) = 3.54 ft vcl = (Rl-Fl)/L1 = T3 = (L2*Lo2)/(L2+L3) = 4.80 ft vc2 = (R2-F2-F3)/L2 = T4 = (L3*Lo2)/(L2+L3) = 1.20 ft vc3 = (R3-F4)/L3 = 150 plf 198 plf 163 plf 2987 lbf OK 225lbf 2290 lbf 471lbf 120lbf 373lbf 195lbf 80 plf 32 plf 67 plf Check Summary of Shear Values for Two Openings Line 1: vc1 hal+hbl +v1 ho1 =H? 319 600 920 lbf Line 2: val(hal+hbl)-vcl(hal+hbl)-vl(hol)=0? 920 319 600 0 Line 3:vc2(hal+hbl)+v2(hol)-val(hal+hbl)=0? 129 791 920 0 Line 4: va2(ha2+hb2)-v2(ho2)-vc2(ha2+hb2)=0? 920 791 129 0 Line 5: va2(ha2+hb2)-vc3(ha2+hb2)-v3(ho2)=0? 920 269 650 0 Line 6: vc3(ha2+hb2)+v3(ho2) = H? 269 650 920 lbf Req. HD Req. Shear Wall Anchorage Design Summary* 4-Term Deflection *The Design Summary assumes that the shear wall is designed as blocked. Project Information Code: 20181BC Date: 4/4/2022 Designer: Client: Project: SDA#9508 Wall Line: ROOF -REAR LI(ft( V(lb) Lol(ft) L21ftj f L_1I ft) Shear Wall Calculation Variables V 1731 Ibf Opening 1 Adj. Factor Method = 2bs/I Ll 3.00 ft haA7.90 Wall Pier Aspect Ratio Adj. Fa( L2 3.00 ft ho Pl=hdL1= 1.50 N/A hwan 7.83 ft hb P2=hdL2= 1.50 N/A L-11 13.90 ft Lol 1. Hold-down forces: H = Vh_,dLw ,, 975 Ibf 2. Unit shear above+ below opening First opening: val = vbl = H/(h,+hb) = 293 plf 3. Total boundary force above +below openings First opening: 01 = val x (Lol) = 2313 Ibf 4. Corner forces F1 = Ol(Ll)/(L1+L2) = 1157 Ibf F2 = Ol(L2)/(Ll+L2) = 1157 Ibf S. Tributary length of openings T1= (Ll*Lol)/(Ll+L2) = 3.95 ft T2 = (L2*Lol)/(L1+L2) = 3.95 ft 6. Unit shear beside opening vl = (V/L)(Ll+Tl)/Ll = 289 plf v2 = (V/L)(T2+L2)/L2 = 289 plf Check vl*Ll+v2*L2=V? 1731 lbf OK 7. Resistance to corner forces R1= v1*L1= 866 Ibf R2 = v2*L2 = 866 Ibf 8. Difference corner force + resistance Rl-Fl = -291 Ibf R2-F2 = -291 Ibf 9. Unit shear in corner zones vcl = (Rl-Fl)/Ll = -97 plf vc2 = (R2-F2)/L2 = -97 plf Check Summary of Shear Values for One Opening Line 1: vcl(ha+hb)+vl(hj=H? -323 1298 975 Ibf Line 2: val(h,+hb)-vcl(h,+hb)-vl(h,)=0? 975 -323 1298 0 Line 3: va1(ha+hb)-vc2(ha+hb)-v1(ho)=0? 975 -323 1298 0 Line 4: vc2(h,+hb)+v2(h,)=H? -323 1298 975 Ibf Design Summary* Req. Sheathing Capacity 293 plf 4-Term Deflection 3-Term Deflection Req. Strap Force 1157 Ibf 4-Term Story Drift % 3-Term Story Drift Req. HD Force (H) 975 Ibf Req. Shear Wall Anchorage Force (vm„) 125 plf *The Design Summary assumes that the shear wall is designed as blocked. Project Information Code: 20181BC Date: 4/4/2022 Designer: Client: Project: SDAN9508 Wall Line: ROOF -RIGHT LI(ft) Lol(ft L2(ft) La2(ft) U3 ft) V (Ib "s L.aii(ft) Shear Wall Calculation Variables V 3443 Ibf Opening 1 Opening 2 Adj. Factor Method = 2bs/h L1 4.00ft halA6.00 hat 1.00ft Wall Pier Aspect Ratio Adj. Factor L2 8.40 ft hol ho2 4.00 ft Pl=h L1= 1.00 N/A L3 3.80 ft hbl hb2 3.00 ft P2=hJL2= 0.48 N/A h.an 8.00 ft Lo1 Lo2 6.00 ft P3=hJL3= 1.05 N/A L.an 28.20 ft 1. Hold-down forces: H = Vh_,,/L.aII 977 lbf 6. Unit shear beside opening 2. Unit shear above +below opening vl = (V/L)(Ll+T1)/L1 = 181 plf First opening: vat = vb1 = H/(hal+hbl) = 244 plf v2 = (V/L)(T2+L2+T3)/L2 = 241 plf Second opening: vat = vb2 = H/(ha2+hb2) = 244 plf v3 = (V/L)(T4+L3)/L3 = 182 plf Check vl*L1+v2*L2+v3*L3=V? 3443 lbf OK 3. Total boundary force above + below openings First opening: 01 = val x (Lol) = 1465 lbf 7. Resistance to corner forces Second opening: 02 = vat x (Lo2) = 1465 lbf Rl = v1*L1 = 725 lbf R2=v2*L2= 2026 lbf 4. Corner forces R3 = v3*L3 = 692 lbf Fl = 01(Ll)/(Ll+L2) = 473 lbf F2 = 01(L2)/(Ll+L2) = 992 lbf B. Difference corner force + resistance F3 = O2(L2)/(L2+L3) = 1009 lbf RI-F1 = 252 lbf F4 = O2(L3)/(L2+L3) = 456 lbf 1124243 = 25 lbf R3-F4= 236 lbf S. Tributary length of openings T1 = (L1*Lol)/(Ll+L2) = 1.94 ft 9. Unit shear in corner zones T2 = (L2*Lol)/(Ll+L2) = 4.06 ft vcl = (R1-F1)/L1 = 63 plf T3 = (L2*Lo2)/(L2+L3) = 4.13 ft vc2 = (R2-F2-F3)/L2 = 3 plf T4 = (L3*Lo2)/(L2+L3) = 1.87 ft vc3 = (R3-F4)/L3 = 62 plf Check Summary of Shear Values for Two Openings Line 1: vc1 hal+hbl +v1 ho1 =H? 252 725 977 lbf Line 2:val(hal+hbl)-vcl(hal+hbl)-vl(hol)=0? 977 252 725 0 Line 3:vc2(hal+hbl)+v2(hol)-val(hal+hbl)=0? 12 965 977 0 Line 4: va2(ha2+hb2)-v2(ho2)-vc2(ha2+hb2)=0? 977 965 12 0 Line 5: va2(ha2+hb2)-vc3(ha2+hb2)-v3(ho2)=0? 977 248 729 0 Line 6: vc3(ha2+hb2)+v3(ho2) = H? 248 729 977 lbf Req. Strap Req. HD Req. Shear Wall Anchorage Design Summary* 4-Term Deflection *The Design Summary assumes that the shear wall is designed as blocked. Project Title: Engineer: Project ID: SDA#9508 Project Descr: Wood Column File:9508.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 KW-06014008 Structural Design Associates DESCRIPTION: ROOF TRELLIS POST Code References Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Analysis Method : Allowable Stress Design End Fixities Top Free, Bottom Fixed Overall Column Height 16.5 ft ( Used for non -slender calculations ) Wood Species Hem -Fir Wood Grade No.2 Fb + 850.0 psi Fv 150.0 psi Fb - 850.0 psi Ft 525.0 psi Fc - Prll 1,300.0 psi Density 26.840 pcf Fc - Perp 405.0 psi E : Modulus of Elasticity ... x-x Bending y-y Bending Basic 1,300.0 1,300.0 Minimum 470.0 470.0 Wood Section Name 6x6 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Exact Width 5.50 in Allow Stress Modification Factors Exact Depth 5.50 in Cf or Cv for Bending 1.0 Area 30.250 inA2 Cf or Cv for Compression 1.0 Ix 76.255 inA4 Cf or Cv for Tension 1.0 ly 76.255 inA4 Cm: Wet Use Factor 1.0 Incising Factors: Ct : Temperature Factor 1.0 for Bending 0.80 Cfu : Flat Use Factor 1.0 Axial for Elastic Modulus 0.95 Kf : Built-up columns 1 ,0 NDS 15.3.2 1,300.0 ksi Use Cr : Repetitive ? No Brace condition for deflection (buckling) along columns : X-X (width) axis : Lu for buckling ABOUT Y-Y Axis : 8 ft, K = 2.1 Y-Y (depth) axis : Lu for buckling ABOUT X-X Axis: 8 ft, K = 2.1 Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weight included : 93.031 Ibs * Dead Load Factor AXIAL LOADS ... TRELLIS: Axial Load at 16.50 ft, D = 0.3330, S = 1.126 k Axial Load at 8.0 ft, D = 0.2050, L = 1.230, S = 0.5130 k BENDING LOADS ... Lat. Point Load at 16.50 ft creatinq Mx-x, W = 0.0730, E = 0.1660 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = 0.9517 : 1 Maximum SERVICE Lateral Load Reactions . . Load Combination +D+0.750L+0.750S+0.5250E Top along Y-Y 0.0 k Bottom along Y-Y 0.1660 k Governing NDS Foruml$1 Comp + Mxx, NDS Eq. 3.9-3 Top along X-X 0.0 k Bottom along X-X 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections.. . At maximum location values are ... Along Y-Y 4.538 in at 16.50 ft above base Applied Axial 2.783 k for load combination : E Only Applied Mx -1.438 k-ft Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base Fc: Allowable 276.528 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio = 0.03001 : 1 Bending Compression Tension Load Combination +D+0.70E Location of max.above base 16.389 ft Applied Design Shear 5.762 psi Allowable Shear 192.0 psi Load Combination Results Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location D Only 0.900 0.285 0.07832 PASS 0.0 ft 0.0 PASS 16.50 ft +D+L 1.000 0.231 0.2432 PASS 16.50 ft 0.0 PASS 16.50 ft +D+S 1.150 0.203 0.2969 PASS 16.50 ft 0.0 PASS 16.50 ft +D+0.750L 1.250 0.187 0.1983 PASS 16.50 ft 0.0 PASS 16.50 ft +D+0.750L+0.750S 1.150 0.203 0.3668 PASS 16.50 ft 0.0 PASS 16.50 ft +D+0.60W 1.600 0.166 0.3156 PASS 0.0 ft 0.01131 PASS 16.389 ft +D+0.750L+0.450W 1.600 0.166 0.2970 PASS 0.0 ft D.008484 PASS 16.389 ft +D+0.750L+0.750S+0.450W 1.600 0.166 0.4277 PASS 0.0 ft D.008484 PASS 16.389 ft Project Title: Engineer: Project ID: SDA#9508 Project Descr: "C.'°uO.8.2 Wood Column Software copyright ENERCALC, INC. 1983-2020 , BuiId:12.20.8.24 DESCRIPTION: ROOF TRELLIS POST Load Combination Results Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location +0.60D+0.60W 1.600 0.166 0.3026 PASS 0.0 ft 0.01131 PASS 16.389 ft +D+0.70E 1.600 0.166 0.8280 PASS 0.0 ft 0.03001 PASS 16.389 ft +D+0.750L+0.750S+0.5250E 1.600 0.166 0.9517 PASS 0.0 ft 0.02251 PASS 16.389 ft +0.60D+0.70E 1.600 0.166 0.7994 PASS 0.0 ft 0.03001 PASS 16.389 ft Maximum Reactions Note: Only non -zero reactions are listed. X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My - End Moments k-ft Mx - End Moments Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top D Only 0.631 +D+L 1.861 +D+S 2.270 +D+0.750L 1.554 +D+0.750L+0.750S 2.783 +D+0.60W 0.044 0.631 0.723 +D+0.750L+0.450W 0.033 1.554 0.542 +D+0.750L+0.750S+0.450W 0.033 2.783 0.542 +0.60D+0.60W 0.044 0.379 0.723 +D+0.70E 0.116 0.631 1.917 +D+0.750L+0.750S+0.5250E 0.087 2.783 1.438 +0.60D+0.70E 0.116 0.379 1.917 L Only 1.230 S Only 1.639 W Only 0.073 1.205 E Only 0.166 2.739 Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance D Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft +D+L 0.0000 in 0.000 ft 0.0000 in 0.000 ft +D+S 0.0000 in 0.000 ft 0.0000 in 0.000 ft +D+0.750L 0.0000 in 0.000 ft 0.0000 in 0.000 ft +D+0.750L+0.750S 0.0000 in 0.000 ft 0.0000 in 0.000 ft +D+0.60W 0.0000 in 0.000 ft 1.1973 in 16.500 ft +D+0.750L+0.450W 0.0000 in 0.000 ft 0.8980 in 16.500 ft +D+0.750L+0.750S+0.450W 0.0000 in 0.000 ft 0.8980 in 16.500 ft +0.60D+0.60W 0.0000 in 0.000 ft 1.1973 in 16.500 ft +D+0.70E 0.0000 in 0.000 ft 3.1765 in 16.500 ft +D+0.750L+0.750S+0.5250E 0.0000 in 0.000 ft 2.3824 in 16.500 ft +0.60D+0.70E 0.0000 in 0.000 ft 3.1765 in 16.500 ft L Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft S Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft W Only 0.0000 in 0.000 ft 1.9956 in 16.500 ft E Only 0.0000 in 0.000 ft 4.4919 in 16.389 ft Wood Column DESCRIPTION: ROOF TRELLIS POST Sketches 0 Lr) 5.50 in Load 2 Project Title: Engineer: Project ID: SDA#9508 Project Descr: +X Software copyright ENERCAI-C, INC.1983-2020, Build:12.20.8.24 1.459k 1-k Fastener Designer: Solutions Report Report Generated: April 11, 2022 Ledger Inputs Ledger Connection Options Strong -Drive® SDWS TIMBER Screw Structural Wood -to -Wood Connections Including Ledgers �SZT 11/2" to 2" from top of ledger and rim board 6" from end of ledger On -center spacing Ledger fastener spacing may be offset up to 3" to avoid interference with joist attachment and rim board 3" minimum row spacing, 6" maximum SIMPSON Designed to provide an easy -to -install, high -strength alternative to through -bolting and traditional lag screws. The SDWS structural wood screws are ideal for the contractor and do-it-yourselfer alike. Features: • Bold thread design that provides superior holding power. • Patented SawToothTM point ensures fast starts, reduces installation torque and eliminates the need for pre -drilling in most applications. • Under -head nibs that offer greater control when seating the head. • Large low -profile washer head provides maximum bearing area (0.75" head dia.). • Size identification on all SDWS screw heads. www.strongtie.com/fd Page 1 of 2 Fastener Designer: Solutions Report Report Generated: April 11, 2022 • _ • 6-lobe T-40 drive reduces driver -bit cam -outs, resulting in easier installations and longer bit life. Double -barrier coating provides corrosion resistance equivalent to hot -dip galvanization, making it suitable for certain exterior and preservative -treated wood applications, as described in the evaluation report. Notes • Screw spacing values are equivalent to 2012/2015 IRC Table R507.2. • Fastener spacings are based on the lesser of single fastener ICC-ES AC233 testing of the screw with a safety factor of 5.0 or ICC-ES AC13 ledger assembly testing with a safety factor of 5.0. • Ledger To Rim Board spacing requirements were developed using an NDS wet service factor of 0.7. • Ledger To Rim Board with One or Two Layers of 5/8" Gypsum Board were developed using an NDS wet service factor of 1.0. • Multiple ledger plies shall be fastened together per code independent of the screws. • Structural sheathing between the ledger and band shall be a maximum of 1 /2" thick and fastened per code. Codes/Standards: Click Here Product Information: Strong -Drive SDWS TIMBER Screw www.strongtie.com/fd Page 2 of 2 91FORTEZM JOB SUMMARY REPORT 9508 ROOF Member Name Results Current Solution Comments RBI Passed 1 piece(s) 2 x 12 DF No.2 @ 24" OC R62 Passed 1 piece(s) 4 x 12 HF No.2 RB3 Passed 1 piece(s) 4 x 12 HF No.2 R64 Passed 1 piece(s) 8 3/4" x 19 1/2" 24F-V4 DF Glulam RB4 Passed 1 piece(s) 3 1/2" x 9 1/2" 1.55E Tim berStrand@ LSL (Plank) R135 Passed 1 piece(s) 4 x 10 HF No.2 RB6 Passed 1 piece(s) 4 x 6 HF No.2 RB7 Passed 1 piece(s) 3 1/2" x 11 7/8" 24F-V4 DF Glulam RB7 [1] Passed 1 piece(s) 4 x 8 HF No.2 (Plank) RB7 [2] Passed 1 piece(s) 3 1/2" x 9 1/2" 1.55E TimberStrand@ LSL (Plank) RB8 Passed 1 piece(s) 4 x 8 HF No.2 RB9 Passed 1 piece(s) 4 x 8 HF No.2 RB10 Passed 1 piece(s) 5 1/2" x 7 1/2" 24F-V4 DF Glulam RB11 Passed 1 piece(s) 5 1/2" x 7 1/2" 24F-V4 DF Glulam RB12 Passed 1 piece(s) 4 x 6 HF No.2 RB13 Passed 1 piece(s) 4 x 6 HF No.2 RB14 Passed 1 piece(s) 3 1/2" x 7 1/2" 24F-V4 DF Glulam RB15 Passed 1 piece(s) 6 x 8 HF No.2 RB15 Passed 1 piece(s) 6 x 6 HF No.2 RB16 Passed 1 piece(s) 6 x 8 HF No.2 RB17 Passed 1 piece(s) 4 x 8 HF No.2 RB18 Passed 1 piece(s) 4 x 6 HF No.2 RB19 Passed 1 piece(s) 4 x 6 HF No.2 RB20 Passed 1 piece(s) 6 x 10 HF No.2 RB21 Passed 1 piece(s) 4 x 8 HF No.2 @ 19.2" OC RB22 Passed 1 piece(s) 3 1/2" x 10 1/2" 24F-V8 DF Glula m RB22 Passed 1 piece(s) 4 x 8 HF No.2 (Plank) RB23 Passed 1 piece(s) 1 3/4" x 7 1/4" 2.oE Microllam@ LVL @ 24" OC 2ND LEVEL Member Name Results Current Solution Comments MBl Passed 1 piece(s) 2 x 8 HF No.2 @ 16" OC MB2 Passed 1 piece(s) 4 x 10 HF No.2 MB3 Passed 1 piece(s) 4 x 6 HF No.2 MB4 Passed 1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam MB4 Passed 1 piece(s) 4 x 8 HF No.2 (Plank) M B5 Passed 1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam M B5 Passed 1 piece(s) 4 x 8 HF No.2 (Plank) MB6 Passed 1 piece(s) 4 x 8 HF No.2 MB6 Passed 2 piece(s) 2 x 4 HF No.2 MB7 Passed 1 piece(s) 4 x 6 HF No.2 MB8 Passed 1 piece(s) 4 x 6 HF No.2 MB9 Passed 2 piece(s) 2 x 12 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB v3.2 Weyerhaeuser File Name: 9508 Page 1 / 42 a FORTE'M3 MEMBER REPORT ROOF, RBI 1 piece(s) 2 x 12 DF No.2 @ 24" OC PASSED 0 12 4F 0 Sloped Lengih: 1T 8 15/16' 16' 3" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 687 @ 2 1/2" 2231 (3.50") Passed (31%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 591 @ P 2 3/16" 2329 Passed (25%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 2750 @ 8' 5" 3138 Passed (88%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.319 @ 8' 5" 0.865 Passed (L/651) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.520 @ 8' 5" 1.154 Passed (L/399) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Beveled Plate - SPF 3.50" 3.50" 1.50" 266 337 421 1024 Blocking 2 - Beveled Plate - SPF 3.50" 3.50" 1.50" 266 337 421 1024 Blocking • rsiocKmg raneis are assumea to carry no ioaas appnea aireary aoove mem ano me run ioaa is appuea to me memoer Deing aesignea. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 4' o/c Bottom Edge (Lu) 17' 9" o/c -Maximum allowable bracing intervals based on applied load. Vertical Load Location (Side) Spacing Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 16' 10" 24" 15.0 20.0 25.0 Default Load Member Length : 18' 11/16" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Member Pitch : 4/12 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 2 / 42 a FORTE'M3 MEMBER REPORT ROOF, RB2 1 piece(s) 4 x 12 HF No.2 Sloped Length: 21' 3 7/16' 8' 13116" i 0 8' 8 3/8" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1025 @ 20' 3 13/16" 2126 (1.50") Passed (48%) 1.0 D + 1.0 S (Alt Spans) Shear (Ibs) 928 @ 12' 8 1/16" 4528 Passed (20%) 1.15 1.0 D + 1.0 S (Adj Spans) Moment (Ft-Ibs) 1728 @ 16' 9 3/4" 6615 Passed (26%) 1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in) 0.025 @ 16' 3 3/8" 0.449 Passed (L/999+) 1.0 D + 1.0 S (Alt Spans) Total Load Defl.(in) 0.041 @ 16'3 5/8" 0.599 Passed (L/999+) 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Overhang deflection criteria: LL (2L/240) and TL (2L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Beveled Plate - SPF 3.50" 3.50" 1.50" 203 238 441 Blocking 2 - Beveled Plate - SPF 3.50" 3.50" 1.50" 699 1002 1701 None 3 - Hanger on 11 1/4" SPF beam 3.50" Hanger' 1.50" 409 616 1025 See note' • isiocKmg raneis are assumea co carry no ioaas appnea airecay aoove mem ano me run ioaa is appnea co me memoer Deing aesignea. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ' See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 21' o/c Bottom Edge (Lu) 21' o/c -Maximum allowable bracing intervals based on applied load. PASSED Member Length : 21' 2 3/4" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASO Member Pitch : 3.1/12 Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 3 - Face Mount Hanger LSSR41OZ 1.88" N/A 22-16dx2.5 18-16dx2.5 • Kerer to manuracturer notes and instructions tor proper installation and use or all connectors. Dead Snow Vertical Loads Location (Side) Tributary Width (0.90) (1.15) Comments 0 - Self Weight (PLF) 0 to 20' 3 13/16" N/A 10.0 1 - Tapered (PLF) 0 to 3' 6 5/8" N/A 0.0 to 51.5 0.0 to 82.6 Generated from Roof Geometry 2 - Tapered (PLF) 3' 6 5/8" to 20' 3 13/16" N/A 0.0 to 116.3 0.0 to 195.1 Generated from Roof Geometry ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC FOrteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 3 / 42 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB software operator 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.O.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 4 / 42 Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com a FORTE"M3 MEMBER REPORT ROOF, RB3 1 piece(s) 4 x 12 HF No.2 Overall Length: 1B' B 1/2" � 7' 1 fl" 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2056 @ 16' 6 3/4" 4961 (3.50") Passed (41%) 1.0 D + 1.0 S (Adj Spans) Shear (Ibs) 947 @ 9' 6 1/4" 4528 Passed (21%) 1.15 1.0 D + 1.0 S (Adj Spans) Moment (Ft-Ibs) -1591 @ 8' 5 1/4" 6615 Passed (24%) 1.15 1.0 D + 1.0 S (Adj Spans) Live Load Defl. (in) 0.017 @ 12' 8 7/8" 0.406 Passed (L/999+) 1.0 D + 1.0 S (Alt Spans) Total Load Defl.(in) 0.025 @ 12'8 7/8" 0.542 Passed (L/999+) 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Overhang deflection criteria: LL (2L/240) and TL (2L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Hanger on 11 1/4" SPF beam 3.50" Hangers 1.50" 122 148 186 456 See note 1 2 - Stud wall - SPF 3.50" 3.50" 1.50" 829 965 1206 3000 Blocking 3 - Beam - DF 3.50" 3.50" 1.50" 823 987 1234 3044 None • isiocKmg Tanis are assumea co carry no ioaas appnea airecoy aoove mem ano me Tull ioaa is appnea co me memoer Deing aesigneo. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • 1 See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 18' 5" o/c Bottom Edge (Lu) 18' 5" o/c -Maximum allowable bracing intervals based on applied load. PASSED System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASO Member Pitch : 0/12 Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1- Face Mount Hanger LUS48 2.00" N/A 6-10dx1.5 4-10d • Kerer to manufacturer notes and instructions Tor proper installation and use or all connectors. Vertical Loads Location (Side) Tributary Width Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 0 - Self Weight (PLF) 3 1/2" to 18' 8 1/2" N/A 10.0 1 - Tapered (PSF) 0 to 18' 8 1/2" (Front) 1' to 9' 9" 15.8 20.0 25.0 Default Load Weyerhaeuser Notes EqEMF111111111111= ill Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/wGodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 5 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB4 1 piece(s) 8 3/4" x 19 1/2" 24F-V4 DF Glulam Overall Length: 34' 3' 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 11323 @ 34' 1" 13016 (3.50") Passed (87%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 9991 @ 32' 4" 34665 Passed (29%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 90875 @ 173 3/4" 109779 Passed (83%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 1.118 @ 17' 1 15/16" 1.696 Passed (L/364) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 1.954 @ 17' 1 7/8" 2.261 Passed (L/208) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 0.86 that was calculated using length L = 33' 11". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports IV Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Stud wall - SPF 3.50" 3.50" 2.83" 4525 4450 6005 14980 Blocking 2 - Stud wall - SPF 3.50" 3.50" 3.04" 4826 5058 6497 16381 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the toll load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 34' 3" o/c Bottom Edge (Lu) 34' 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (non -snow: 1.25) (1.15) Comments 0 - Self Weight (PLF) 0 to 34' 3" N/A 41.5 1 - Uniform (PSF) 0 to 20' (Front) 12' 15.8 20.0 25.0 Default Load 2 - Uniform (PSF) 20' to 34' 3" (Front) 16' 15.8 20.0 25.0 Default Load 3 - Point (lb) 9' 9" (Front) N/A 122 148 186 Linked from: RB3, Support 1 4 - Point (lb) 9' 9" (Front) N/A 409 616 Linked from: RB2, Support 3 System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser Notes W Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 6 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB4 1 piece(s) 3 1/2" x 9 1/2" 1.55E TimberStrand@ LSL (Plank) Drawing is Conceptual Wall Height: 11' 3" Member Height: 10' 10 1/2" Tributary Width: 3' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (63%) -- -- Compression (Ibs) 10530 20745 Passed (51%) 1.15 1.0 D + 1.0 S Plate Bearing (Ibs) 10530 13466 Passed (78%) -- 1.0 D + 1.0 S Lateral Reaction (Ibs) 238 1.60 1.0 D + 0.6 W Lateral Shear (lbs) 225 5320 Passed (4%) 1.60 1.0 D + 0.6 W Lateral Moment (ft-Ibs) 648 @ mid -span 6763 Passed (10%) 1.60 1.0 D + 0.6 W Total Deflection (in) 0.47 @ mid -span 1.09 Passed (L/279) -- 1.0 D + 0.45 W + 0.75 L + 0.75 S Bending/Compression 0.95 1 Passed (95%) 1.15 1.0 D + 1.0 S • Lateral deflection criteria: Wind (L/120) • Input axial load eccentricity for this design is 50% of applicable member side dimension. • Applicable calculations are based on NDS. • Bearing shall be on a metal plate or strap, or on other equivalently durable, rigid, homogeneous material with sufficient stiffness to distribute applied load. • Member has been designed in flat (plank) orientation with lateral (wind) loads applied to wide strand face. Supports Type Material Top Dbl 2X Hem Fir Base 2X Hem Fir Max Unbraced Length Comments 1' Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 10d x 3" Box (End) 3 N/A Base Nails 10d x 3" Box (End) 3 N/A System : Wall Member Type : Column Building Code : IBC 2015 Design Methodology : ASD • Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Vertical Load Tributary Width Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Point (lb) N/A 4525 4450 6005 Linked from: RB4, Support 1 Lateral Load Location Tributary Width Wind (1.60) Comments 1 - Uniform (PSF) Full Length 3' 24.3 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC AForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 7 / 42 a FORTE"M3 MEMBER REPORT ROOF, RB5 1 piece(s) 4 x 10 HF No.2 PASSED 0 Overall Length: 8' 3" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1757 @ 0 2126 (1.50") Passed (83%) 1.0 D + 1.0 S (All Spans) Shear(lbs) 1375 @ 10 3/4" 3723 Passed (37%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 3624 @ 4' 1 1/2" 4879 Passed (74%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.087 @ 4' 1 1/2" 0.275 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.148 @ 4' 1 1/2" 0.412 Passed (L/669) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 726 825 1031 2582 None 2 - Trimmer - SPF 1.50" 1.50" 1 1.50" 726 825 1031 2582 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 3" o/c Bottom Edge (Lu) 8' 3" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 8' 3" N/A 8.2 1 - Uniform (PSF) 0 to 8' 3" 10' 16.8 20.0 25.0 ROOF 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to vww.weyerhaeuser.com/woodproducts/document-library. the product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 8 / 42 a FORTE'M3 MEMBER REPORT ROOF, RB6 1 piece(s) 4 x 6 HF No.2 PASSED 0 Overall Length: 6' 3" L 6' 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 407 @ 0 2126 (1.50") Passed (19%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 331 @ 7" 2214 Passed (15%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 636 @ 3' 1 1/2" 1869 Passed (34%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.041 @ 3' 1 1/2" 0.208 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.071 @ 3' 1 1/2" 0.313 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 172 188 234 594 None 2 - Trimmer - SPF 1.50" 1.50" 1 1.50" 172 188 234 594 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 6' 3" o/c Bottom Edge (Lu) 63" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 6' 3" N/A 4.9 1 - Uniform (PSF) 0 to 6' 3" 3' 16.8 20.0 25.0 ROOF 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to vww.weyerhaeuser.com/woodproducts/document-library. the product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 9 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB7 1 piece(s) 3 1/2" x it 7/8" 24F-V4 DF Glulam Overall Length: 6' 9" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 8761 @ 6' 6" 10238 (4.50") Passed (86%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 8576 @ 5' 4 5/8" 8444 Passed (102%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 14356 @ 4' 10" 18920 Passed (76%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.051 @ T 7 13/16" 0.208 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.088 @ 3' 7 13/16" 0.313 Passed (L/848) 1 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 6' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports IF Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Trimmer - SPF 4.50" 4.50" 1.53" 1491 1551 1986 5028 None 2 - Trimmer - SPF 4.50" 4.50" 3.85" 3743 3912 5018 12673 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 6' 9" o/c Bottom Edge (Lu) 6' 9" o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location Tributary Width (0.90) (non -snow: 1.25) (1.15) Comments 0 - Self Weight (PLF) 0 to 6' 9" N/A 10.1 1 - Uniform (PSF) 0 to 6' 9" 3' 16.8 20.0 25.0 ROOF 2 - Point (lb) 4' 10" N/A 4826 5058 6497 Linked from: RB4, Support 2 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASO Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 10 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB7 [11 1 piece(s) 4 x 8 HF No.2 (Plank) Wall Height: 12' Member Height: 11' 7 1/2" Tributary Width: 4' Design Results Actual Allowed Result LDF Load: Combination Slenderness 40 50 Passed (80%) Compression (Ibs) 3477 5961 Passed (58%) 1.15 1.0 D + 1.0 S Plate Bearing (Ibs) 3477 10784 Passed (32%) -- 1.0 D + 1.0 S Lateral Reaction (Ibs) 336 1.60 1.0 D + 0.6 W Lateral Shear (lbs) 319 4060 Passed (8%) 1.60 1.0 D + 0.6 W Lateral Moment (ft-Ibs) 976 @ mid -span 2290 Passed (43%) 1.60 1.0 D + 0.6 W Total Deflection (in) 0.51 @ mid -span 1 1.16 Passed (L/272) 1.0 D + 0.6 W Bending/Compression 0.94 1 Passed (94%) 1.60 1.0 D + 0.45 W + 0.75 L + 0.75 S • Lateral deflection criteria: Wind (L/120) • Input axial load eccentricity for this design is 10% of applicable member side dimension. • Applicable calculations are based on NDS. • Member has been designed in flat (plank) orientation with lateral (wind) loads applied to wide strand face. Supports Type Material Top Dbl 2X Spruce -Pine -Fir Base 2X Spruce -Pine -Fir Drawing is Conceptual I Max Unbraced Length Comments 8' Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 10d x 3" Box (End) 4 N/A Base Nails 10d x 3" Box (End) 4 N/A System : Wall Member Type : Column Building Code : IBC 2015 Design Methodology : ASD • Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Vertical Load Tributary Width Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Point (lb) N/A 1491 1551 1986 Linked from: RB7, Support 1 Lateral Load Location Tributary Width Wind (1.60) Comments 1 - Uniform (PSF) Full Length 4' 24.1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC AForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 11 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB7 [21 1 piece(s) 3 1/2" x 9 1/2" 1.55E TimberStrand@ LSL (Plank) Wall Height: 12' Member Height: 11' 7 1/2" Tributary Width: 4' Design Results Actual Allowed Result LDF Load: Combination Slenderness 34 50 Passed (68%) -- -- Compression (Ibs) 8761 18246 Passed (48%) 1.15 1.0 D + 1.0 S Plate Bearing (Ibs) 8761 14131 Passed (62%) -- 1.0 D + 1.0 S Lateral Reaction (Ibs) 336 1.60 1.0 D + 0.6 W Lateral Shear (lbs) 319 5320 Passed (6%) 1.60 1.0 D + 0.6 W Lateral Moment (ft-Ibs) 976 @ mid -span 6763 Passed (14%) 1.60 1.0 D + 0.6 W Total Deflection (in) 0.35 @ mid -span 1 1.16 Passed (L/398) -- 1.0 D + 0.6 W Bending/Compression 0.41 1 Passed (41%) 1.60 1.0 D + 0.45 W + 0.75 L + 0.75 S • Lateral deflection criteria: Wind (L/120) • Input axial load eccentricity for this design is 10% of applicable member side dimension. • Applicable calculations are based on NDS. • Member has been designed in flat (plank) orientation with lateral (wind) loads applied to wide strand face. Supports Type Material Top Dbl 2X Spruce -Pine -Fir Base 2X Spruce -Pine -Fir Drawing is Conceptual I Max Unbraced Length Comments 8' Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 10d x 3" Box (End) 4 N/A Base Nails 10d x 3" Box (End) 4 N/A System : Wall Member Type : Column Building Code : IBC 2015 Design Methodology : ASD • Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Vertical Load Tributary Width Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Point (lb) N/A 3743 3912 5018 Linked from: RB7, Support 2 Lateral Load Location Tributary Width Wind (1.60) Comments 1 - Uniform (PSF) Full Length 4' 24.1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC AForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 12 / 42 a FORTE'M3 MEMBER REPORT ROOF, RB8 1 piece(s) 4 x 8 HF No.2 PASSED 0 Overall Length: 7' 3" L 7' 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 782 @ 7' 3" 2126 (1.50") Passed (37%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 686 @ 6' 6 1/4" 2918 Passed (23%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1433 @ 4' 7 15/16" 3247 Passed (44%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.051 @ 3' 9 1/16" 0.242 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.091 @ 3' 9 1/8" 0.313 Passed (L/958) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/5/16"). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 269 218 346 833 None 2 - Trimmer - SPF 1.50" 1.501. 150" 346 218 436 1000 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 7' 3" o/c Bottom Edge (Lu) 7' 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location Tributary Width (0.90) (non -snow: 1.25) (1.15) Comments 0 - Self Weight (PLF) 0 to 7' 3" N/A 6.4 1 - Uniform (PSF) 0 to 7' 3" 3' 16.8 20.0 25.0 ROOF 2 - Point (lb) 5' N/A 203 - 238 Linked from: RB2, Support 1 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 13 / 42 a FORTE'M3 MEMBER REPORT ROOF, RB9 1 piece(s) 4 x 8 HF No.2 PASSED 0 Overall Length: 5 3" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1642 @ 5' 3" 2126 (1.50") Passed (77%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1546 @ 4' 6 1/4" 2918 Passed (53%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1949 @ 4' 3247 Passed (60%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.033 @ 2' 10 1/16" 0.175 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.057 @ 2' SO" 0.262 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 315 158 435 908 None 2 - Trimmer - SPF 1.50" 1.50" 1 1.50" 682 158 960 1800 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 53" o/c Bottom Edge (Lu) 5' 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location Tributary Width (0.90) (non -snow: 1.25) (1.15) Comments 0 - Self Weight (PLF) 0 to T 3" N/A 6.4 1 - Uniform (PSF) 0 to T 3" 3' 16.8 20.0 25.0 ROOF 2 - Point (lb) 4' N/A 699 - 1002 Linked from: RB2, Support 2 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 14 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB10 1 piece(s) 5 1/2" x 7 1/2" 24F-V4 DF Glulam Overall Length: 16' 5 1 j2' 0 0 15' 10 112" YI All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1160 @ 2" 8181 (3.50") Passed (14%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1151 @ 11" 8381 Passed (14%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 8499 @ 7' 9" 11859 Passed (72%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.521 @ 8' 1 1/4" 0.806 Passed (L/372) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.922 @ 8' 1 5/16" 1 1.075 1 Passed (L/210) 1 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 16' 1 1/2". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports IV Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Stud wall - SPF 3.50" 3.50" 1.50" 522 511 639 1672 Blocking 2 - Stud wall - SPF 3.50" 3.50" 1.50" 472 454 567 1493 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 16' 6" o/c Bottom Edge (Lu) 16' 6" o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (non -snow: 1.25) (1.15) Comments 0 - Self Weight (PLF) 0 to 165 1/2" N/A 10.0 1 - Point (lb) 7' 9" (Front) N/A 829 965 1206 Linked from: RB3, Support 2 System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 15 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB11 1 piece(s) 5 1/2" x 7 1/2" 24F-V4 DF Glulam Overall Length: 10' 1' 7' 6" YI 1 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. z' 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 423 @ 7' 11 1/4" 8181 (3.50") Passed (5%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 394 @ 7' 2" 8381 Passed (5%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 543 @ 6' 6" 11859 Passed (5%) 1.15 1.0 D + 1.0 S (All Spans) Neg Moment (Ft-Ibs) -23 @ 7' 11 1/4" 7154 Passed (0%) 0.90 1.0 D (All Spans) Live Load Defl. (in) 0.006 @ 4' 6 1/4" 1 0.389 1 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.013 @ 4' 5 1/8" 1 0.518 1 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Overhang deflection criteria: LL (2L/240) and TL (2L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 7' 8 9/16". • Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 2' 3 1/16". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Stud wall - SPF 3.50" 3.50" 1.50" 75 44 119 Blocking 2 - Stud wall - SPF 3.50" 3.50" 1.50" 229 194 423 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 10' 1" o/c Bottom Edge (Lu) 10' 1" o/c -Maximum allowable bracing intervals based on applied load. Dead Snow Vertical Loads Location (Side) Tributary Width (0.90) (1.15) Comments 0 - Self Weight (PLF) 0 to 10' 1" N/A 10.0 1 - Point (lb) 6' 6" (Front) N/A 203 238 Linked from: RB2, Support 1 System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASO Member Pitch : 0/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 16 / 42 a FORTE'M3 MEMBER REPORT ROOF, RB12 1 piece(s) 4 x 6 HF No.2 PASSED 0 Overall Length: ? L 3' 2" 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 651 @ 0 2126 (1.50") Passed (31%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 428 @ 7" 2214 Passed (19%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 556 @ 1' 8 1/2" 1869 Passed (30%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.011 @ 1' 8 1/2" 0.114 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.019 @ 1' 8 1/2" 0.171 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 266 384 650 None 2 - Trimmer - SPF 1.50" 1.50" 1 1.50" 266 384 650 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 3' 5" o/c Bottom Edge (Lu) 3' 5" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 3' 5" N/A 4.9 1 - Uniform (PSF) 0 to 3' 5" 9' 16.8 25.0 ROOF 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to vww.weyerhaeuser.com/woodproducts/document-library. the product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 17 / 42 a FORTE'M3 MEMBER REPORT ROOF, RB13 1 piece(s) 4 x 6 HF No.2 PASSED 0 Overall Length: 5' L 4' 9" L 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1056 @ 0 2126 (1.50") Passed (50%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 810 @ 7" 2214 Passed (37%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1321 @ 2' 6" 1869 Passed (71%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.056 @ 2' 6" 0.167 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.094 @ 2' 6" 0.250 Passed (L/637) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 431 625 1056 None 2 - Trimmer - SPF 1.50" 1.50" 1 1.50" 431 625 1056 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 5' o/c Bottom Edge (Lu) 5' o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 5' N/A 4.9 1 - Uniform (PSF) 0 to 5' 10' 16.8 25.0 ROOF 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to vww.weyerhaeuser.com/woodproducts/document-library. the product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 18 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB14 1 piece(s) 3 1/2" x 7 1/2" 24F-V4 DF Glulam Overall Length: 10' 6' L 10' 31, L 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2226 @ 0 3413 (1.50") Passed (65%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1908 @ 9" 5333 Passed (36%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 5844 @ 5' 3" 7547 Passed (77%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.309 @ 5' 3" 0.350 Passed (L/408) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.524 @ 5' 3" 0.525 Passed (L/241) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 10' 6". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports IF Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 914 1312 2226 None 2 - Trimmer - SPF 1.50" 1.50" 1.50" 914 1312 2226 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 10' 6" o/c Bottom Edge (Lu) 10' 6" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 10' 6" N/A 6.4 1 - Uniform (PSF) 0 to 10' 6" 10' 16.8 25.0 ROOF System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 19 / 42 a FORTE'M3 MEMBER REPORT ROOF, RB15 1 piece(s) 6 x 8 HF No.2 PASSED Overall Length:4' 1" 3' 6" 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 348 @ 2" 7796 (3.50") Passed (4%) -- 1.0 D + 1.0 S (All Spans) Shear (Ibs) 192 @ 11" 4428 Passed (4%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 300 @ 2' 1/2" 2841 Passed (11%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.002 @ 2' 1/2" 0.188 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.004 @ 2' 1/2" 0.250 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Stud wall - SPF 3.50" 3.50" 1.50" 144 163 204 511 Blocking 2 - Stud wall - SPF 3.50" 3.50" 1 1.50" 144 163 204 511 Blocking • NOCKmg Naneis are assumeo to carry no ioaas appnea airecay above tnem ano the run ioao is appnea to the member being oesigneo. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 4' 1" o/c Bottom Edge (Lu) 4' 1" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 4' 1" N/A 10.4 1 - Uniform (PSF) 0 to 4' 1" (Front) 4' 15.0 20.0 25.0 Default Load System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 20 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB15 1 piece(s) 6 x 6 HF No.2 19 Drawing is Conceptual Post Height: 15' Design Results Actual Allowed Result LDF Load: Combination Slenderness 33 50 Passed (65%) -- -- Compression (Ibs) 578 8161 Passed (7%) 1.15 1.0 D + 1.0 S Base Bearing (Ibs) 578 898425 Passed (0%) -- 1.0 D + 1.0 S Bending/Compression 0.04 1 Passed (4%) 1.15 1.0 D + 1.0 S • Input axial load eccentricity for this design is 16.67% of applicable member side dimension. • Applicable calculations are based on NDS. supports Type Material Member Type : Free Standing Post Base Beam Steel Building Code : IBC 2015 Design Methodology : ASD Max Unbraced Length Comments Full Member Length No bracing assumed. Vertical Loads Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Point (lb) - - - 2 - Point (lb) 144 163 204 Linked from: RB15, Support 2 3 - Point (lb) 120 88 110 Linked from: RB16, Support 1 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC AForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 21 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB16 1 piece(s) 6 x 8 HF No.2 Overall Length: B' 4 112" 0 0 I i 7' 9 1/2" 11 ❑2 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 230 @ 2" 5012 (2.25") Passed (5%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 222 @ 11" 4428 Passed (5%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 779 @ 3' 10 1/2" 2841 Passed (27%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.018 @ 4' 1 1/2" 0.402 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.035 @ 4' 1 5/8" 1 0.536 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Stud wall - SPF 3.50" 2.25" 1.50" 120 88 110 318 1 1/4" Rim Board 2 - Stud wall - SPF 3.50" 2.25" 1 1.50" 109 75 94 278 1 1/4" Rim Board • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 2" o/c Bottom Edge (Lu) 8' 2" o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (non -snow: 1.25) (1.15) Comments 0 - Self Weight (PLF) 1 1/4" to 8' 3 1/4" N/A 10.4 1 - Point (lb) 3' 10 1/2" (Front) N/A 144 163 204 Linked from: RB15, Support 1 System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASO Member Pitch : 0/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 22 / 42 a FORTE'M3 MEMBER REPORT ROOF, RB17 1 piece(s) 4 x 8 HF No.2 PASSED 0 Overall Length: 6' 3" L 6' 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2109 @ 0 2126 (1.50") Passed (99%) 1.0 D + 1.0 S (All Spans) Shear(lbs) 1617 @ 8 3/4" 2918 Passed (55%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 3295 @ 3' 1 1/2" 3247 Passed (SOS%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl.(in) 0.095 @ 3'1 1/2" 0.208 Passed (L/789) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.160 @ 3' 1 1/2" 0.313 Passed (L/468) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 859 1250 2109 None 2 - Trimmer - SPF 1.50" 1.501. 150" 859 1250 2109 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 6" o/c Bottom Edge (Lu) 6' 3" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 6' 3" N/A 6.4 1 - Uniform (PSF) 0 to 6' 3" 16' 16.8 25.0 ROOF 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to vww.weyerhaeuser.com/woodproducts/document-library. the product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 23 / 42 a FORTE"M3 MEMBER REPORT ROOF, RB18 1 piece(s) 4 x 6 HF No.2 PASSED 0 Overall Length: 2' 11" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 982 @ 0 2126 (1.50") Passed (46%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 589 @ 7" 2214 Passed (27%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 716 @ 1' 5 1/2" 1869 Passed (38%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.010 @ 1' 5 1/2" 0.097 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.017 @ 1' 5 1/2" 0.146 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 398 583 981 None 2 - Trimmer - SPF 1.50" 1.50" 1 1.50" 398 583 981 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 2' 11" o/c Bottom Edge (Lu) 2' 11" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 2' 11" N/A 4.9 1 - Uniform (PSF) 0 to 2' 11" 16' 16.8 25.0 ROOF 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to vww.weyerhaeuser.com/woodproducts/document-library. the product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 24 / 42 a FORTE'M3 MEMBER REPORT ROOF, RB19 1 piece(s) 4 x 6 HF No.2 PASSED 0 Overall Length: 6' 3" L 6' 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 668 @ 0 2126 (1.50") Passed (31%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 543 @ 7" 2214 Passed (25%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1044 @ 3' 1 1/2" 1869 Passed (56%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.068 @ 3' 1 1/2" 0.208 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.116 @ 3' 1 1/2" 0.313 Passed (L/645) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 277 391 668 None 2 - Trimmer - SPF 1.50" 1.50" 1 1.50" 277 391 668 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 6' 3" o/c Bottom Edge (Lu) 6' 3" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 6' 3" N/A 4.9 1 - Uniform (PSF) 0 to 6' 3" 5' 16.8 25.0 ROOF 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to vww.weyerhaeuser.com/woodproducts/document-library. the product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 25 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB20 1 piece(s) 6 x 10 HF No.2 Overall Length: 16' a' 13' 9" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1458 @ 1' 3/4" 12251 (5.50") Passed (12%) 1.0 D + 1.0 S (Adj Spans) Shear (Ibs) 1087 @ 2' 1" 5608 Passed (19%) 1.15 1.0 D + 1.0 S (Adj Spans) Moment (Ft-Ibs) 4436 @ 8' 2" 5352 Passed (83%) 1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in) 0.288 @ 8' 2" 0.710 Passed (L/592) 1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in) 0.372 @ 8' 2" 0.947 Passed (L/458) 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Overhang deflection criteria: LL (2L/240) and TL (2L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Lumber grading provisions must be extended over the length of the member per NDS 4.2.5.5. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Column - SPF 5.50" 5.50" 1.50" 333 901 1126 2360 Blocking 2 - Column - SPF 5.50" 5.50" 1 1.50" 333 901 1126 2360 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 16' 4" o/c Bottom Edge (Lu) 16' 4" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 16' 4" N/A 13.2 1 - Uniform (PSF) 0 to 16' 4" (Front) 5' 6" 5.0 20.0 25.0 Default Load System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASO Member Pitch : 0/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 26 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB21 1 piece(s) 4 x 8 HF No.2 @ 19.2" OC 12 ; 41 1' 6" 1❑ Sloped Length: 10' 7 9/16' 6' 6" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 1' 6" ❑z Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 333 @ 1' 7 3/4" 5230 (3.50") Passed (6%) 1.0 D + 1.0 S (Adj Spans) Shear(lbs) 179 @ 2'4 3/8" 2918 Passed (6%) 1.15 1.0 D + 1.0 S (Adj Spans) Moment (Ft-Ibs) 315 @ 5' 1/2" 3734 Passed (8%) 1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in) 0.013 @ 5' 1/2" 0.358 Passed (L/999+) 1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in) 0.019 @ 5' 1/2" 0.477 Passed (L/999+) 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Overhang deflection criteria: LL (2L/240) and TL (2L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Beveled Plate - SPF 3.50" 3.50" 1.50" 128 165 206 499 Blocking 2 - Beveled Plate - SPF 3.50" 3.50" 1 1.50" 128 165 206 499 Blocking • uiocKing raneis are assumea co carry no ioaas appnea airecay aoove mem ano me run ioao is app iea co me memoer Deing aesigneo. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 10' 8" o/c Bottom Edge (Lu) 10' 8" o/c -Maximum allowable bracing intervals based on applied load. Vertical Load Location (Side) Spacing Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 10' 1" 19.2" 15.0 20.0 25.0 Default Load Member Length : 10' 9 15/16" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASO Member Pitch : 4/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/wGodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 27 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB22 1 piece(s) 3 1/2" x 10 1/2" 24F-V8 DF Glulam Overall Length: 17 M 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 5285 @ IT 5 1/4" 7963 (3.50") Passed (66%) 1.0 D + 1.0 S (Adj Spans) Shear (Ibs) 2691 @ 12' 5" 7466 Passed (36%) 1.15 1.0 D + 1.0 S (Adj Spans) Pos Moment (Ft-Ibs) 6464 @ 7' 5 3/8" 14792 Passed (44%) 1.15 1.0 D + 1.0 S (Alt Spans) Neg Moment (Ft-Ibs) -4108 @ 1315 1/4" 14792 Passed (28%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.155 @ 78 3/8" 0.565 Passed (U874) 1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in) 0.229 @ 7' 7 13/16" 0.753 Passed (U591) 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Overhang deflection criteria: LL (2L/240) and TL (2L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 9' 11 13/16". • Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 5' 5 5/16". • The effects of positive or negative camber have not been accounted for when calculating deflection. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Column - SPF 3.50" 3.50" 1.71" 1460 1949 2437 5846 Blocking 2 - Column - SPF 3.50" 3.50" 1 2.32" 2026 2607 3259 7892 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 175" o/c Bottom Edge (Lu) 17' 5" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 175" N/A 8.9 1 - Uniform (PSF) 0 to 17' 5" (Front) 12' 9" 15.0 20.0 25.0 Default Load System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASO Member Pitch : 0/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 28 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB22 1 piece(s) 4 x 8 HF No.2 (Plank) Wall Height: 11' 6" Member Height: 11' 1 1/2" Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 38 50 Passed (76%) -- -- Compression (Ibs) 5285 6486 Passed (81%) 1.15 1.0 D + 1.0 S Plate Bearing (Ibs) 5285 10784 Passed (49%) -- 1.0 D + 1.0 S Lateral Reaction (Ibs) 81 1.60 1.0 D + 0.6 W Lateral Shear (lbs) 77 4060 Passed (2%) 1.60 1.0 D + 0.6 W Lateral Moment (ft-Ibs) 225 @ mid -span 2290 Passed (10%) 1.60 1.0 D + 0.6 W Total Deflection (in) 0.10 @ mid -span 1 1.11 Passed (L/1280) -- 1.0 D + 0.6 W Bending/Compression 0.68 1 Passed (68%) 1.60 1.0 D + 0.45 W + 0.75 L + 0.75 S • Lateral deflection criteria: Wind (L/120) • Input axial load eccentricity for the design is zero • Applicable calculations are based on NDS. • Member has been designed in flat (plank) orientation with lateral (wind) loads applied to wide strand face. Supports Type Material Top Dbl 2X Spruce -Pine -Fir Base 2X Spruce -Pine -Fir Drawing is Conceptual I Max Unbraced Length Comments 8' Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d x 2.5' Box (Toe) 1 N/A Base Nails 8d x 2.5" Box (Toe) 1 N/A System : Wall Member Type : Column Building Code : IBC 2015 Design Methodology : ASD • Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Vertical Load Tributary Width Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Point (lb) N/A 2026 2607 3259 Linked from: RB22, Support 2 Lateral Load Location Tributary Width Wind (1.60) Comments 1 - Uniform (PSF) Full Length 1' 24.3 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC AForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 29 / 42 a" O R T CM MEMBER REPORT PASSED ROOF, RB23 1 piece(s) 1 3/4" x 7 1/4" 2.0E Microllam@ LVL @ 24" OC Sloped Lengih: 16' 9 7/8' 12 41 I'M 2' 6" 12' 10 1 /2" 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Member Length : 17' 1/4" Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 738 @ 2' 7 3/4" 2744 (3.50") Passed (27%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 495 @ 3' 4 3/8" 2772 Passed (18%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1676 @ 9' 4 1/8" 4255 Passed (39%) 1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in) 0.325 @ 9' 2 15/16" 0.691 Passed (L/510) 1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in) 0.529 @ 9' 3" 0.921 Passed (L/313) 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Overhang deflection criteria: LL (2L/240) and TL (2L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 4% increase in the moment capacity has been added to account for repetitive member usage. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Beveled Plate - SPF 3.50" 3.50" 1.50" 264 379 473 1116 Blocking 2 - Beveled Plate - SPF 3.50" 3.50" 1 1.50" 209 265 331 805 Blocking • rsiocKmg raneis are assumea to carry no ioaas appnea aireary aoove mem ano me run ioaa is appuea to me memoer Deing aesignea. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 16' 10" o/c Bottom Edge (Lu) 16' 10" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Spacing Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Uniform (PSF) 2' 6" to 15' 11 1/2" 24" 15.0 20.0 25.0 Default Load 2 - Uniform (PSF) 0 to 2' 6" 24" 9.0 20.0 25.0 Default Load System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASO Member Pitch : 4/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 30 / 42 a FORTE"M3 MEMBER REPORT 2ND LEVEL, MBl 1 piece(s) 2 x 8 HF No.2 @ 16" OC PASSED Overall Length: -, - L $ L 11 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 423 @ 2 1/2" 1367 (2.25") Passed (31%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear(lbs) 326 @ 10 3/4" 1088 Passed (30%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 800 @ 4' 3 1/2" 1284 Passed (62%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.137 @ 4' 3 1/2" 0.204 Passed (L/713) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.163 @ 4' 3 1/2" 1 0.408 1 Passed (L/600) 1.0 D + 0.75 L + 0.75 S (All Spans) TJ-Pro'"" Rating N/A I N/A I N/A N/A • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. • No composite action between deck and joist was considered in analysis. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Stud wall - SPF 3.50" 2.25" 1.50" 69 343 143 555 1 1/4" Rim Board 2 - Stud wall - SPF 3.50" 2.25" 1 1.50" 69 343 143 555 1 1/4" Rim Board • Kim boara is assumea to carry au ioaas appuea airecuy aoove it, Dypassing me memoer Demg aesignea. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 5" o/c Bottom Edge (Lu) 8' 5" o/c -Maximum allowable bracing intervals based on applied load. Vertical Load Location (Side) Spacing Dead (0.90) Floor Live (1.00) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 8' 7" 16" 12.0 60.0 25.0 Default Load System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 31 / 42 a FORTE M3 IL n MEMBER REPORT 2ND LEVEL, MB2 1 piece(s) 4 x 10 HF No.2 Overall Length: 20' 2 112" 0 9' $„ All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. i 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 3817 @ 10' 1 1/4" 4961 (3.50") Passed (77%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 1545 @ 11' 1/4" 3238 Passed (48%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) -3565 @ 10' 1 1/4" 4242 Passed (84%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.117 @ 4' 11 1/8" 0.327 Passed (L/999+) 1.0 D + 1.0 L (Alt Spans) Total Load Defl. (in) 0.133 @ 4' 10 5/16" 0.491 Passed (L/884) 1.0 D + 1.0 L (Alt Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Bearing Length Loads to Supports (Ibs) Total Available Required Dead Floor Live Snow Total Supports Accessories 1 - Hanger on 9 1/4" SPF beam 3.50" Hanger' 1.50" 221 1100/-77 428 174 9/ See note 77 2 - Stud wall- SPF 3.50" 3.50" 2.69" 689 2944 1227 4860 Blocking 3 - Hanger on 9 1/4" SPF beam 3.50" Hanger' 1.50" 221 1100/-77 428 1 77/ See note' • IsiocKing Panels are assumea to carry no ioaas appiiea aireaiy above tnem ana the run ioaa is appiiea to the member Deing aesignea. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ' See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 19' 8" o/c Bottom Edge (Lu) 19' 8" o/c -Maximum allowable bracing intervals based on applied load. PASSED System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger HUC48 2.50" N/A 10-16d 4-10d 3 - Face Mount Hanger HUC48 2.50" N/A 10-16d 4-10d • Reter to manufacturer notes and instructions for proper installation and use of all connectors. Vertical Loads Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Snow (1.15) Comments 0 - Self Weight (PLF) 3 1/2" to 19' 11" N/A 8.2 1 - Uniform (PSF) 0 to 20' 2 1/2" (Front) 4' 12.0 60.0 25.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 32 / 42 a FORTE'M3 MEMBER REPORT 2ND LEVEL, MB3 1 piece(s) 4 x 6 HF No.2 PASSED 0 Overall Length: 6' 3" L 6' 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 706 @ 0 2126 (1.50") Passed (33%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 574 @ 7" 1925 Passed (30%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 1103 @ 3' 1 1/2" 1625 Passed (68%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.093 @ 3' 1 1/2" 0.208 Passed (L/811) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.123 @ 3' 1 1/2" 0.313 Passed (L/610) 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 175 531 706 None 2 - Trimmer - SPF 1.50" 1.50" 1.50" 175 531 706 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 6' 3" o/c Bottom Edge (Lu) 6' 3" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Floor Live (1.00) Comments 0 - Self Weight (PLF) 0 to 6' 3" N/A 4.9 1 - Uniform (PSF) 0 to 6' 3" 4' 3" 12.0 40.0 Floor 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to vww.weyerhaeuser.com/woodproducts/document-library. the product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 33 / 42 a" O R T CM MEMBER REPORT PASSED 2ND LEVEL, MB4 1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam Overall Length: 6' 11" 6' n All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 7875 @ 4" 11172 (5.50") Passed (70%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 7788 @ V 5 1/2" 7619 Passed (102%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 15107 @ 2' 3 1/4" 17250 Passed (88%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.057 @ T 2 11/16" 0.208 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.102 @ T 2 3/4" 0.313 Passed (L/735) 1 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 6' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Supports IF Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Roof Live Snow Total 1 - Trimmer - SPF 5.50" 5.50" 3.88" 3506 588 3213 4370 11677 None 2 - Trimmer - SPF 5.50" 5.50" 1.81" 1704 588 1455 1981 5728 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 6' 11" o/c Bottom Edge (Lu) 6' 11" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Roof Live Snow Vertical Loads Location Tributary Width (0.90) (1.00) (non -snow: 1.25) (1.15) Comments 0 - Self Weight (PLF) 0 to 6' 11" N/A 9.1 -- -- -- 1 - Uniform (PSF) 0 to 6' 11" 4' 3" 12.0 40.0 - Floor 2 - Point (lb) 2' 3 1/4" N/A 4525 4450 6005 Linked from: RB4, Support 1 3 - Point (lb) 2' 6" N/A 269 218 346 Linked from: R68, Support 1 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to NWW.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 34 / 42 a" O R T CM MEMBER REPORT PASSED 2ND LEVEL, MB4 1 piece(s) 4 x 8 HF No.2 (Plank) Wall Height: 7' 9" Member Height: 7' 4 1/2" Tributary Width: 4' Design Results Actual Allowed Result LDF Load: Combination Slenderness 25 50 Passed (51%) Compression (Ibs) 7876 13855 Passed (57%) 1.15 1.0 D + 1.0 S Plate Bearing (Ibs) 7876 10784 Passed (73%) -- 1.0 D + 1.0 S Lateral Reaction (Ibs) 219 1.60 1.0 D + 0.6 W Lateral Shear (Ibs) 202 4060 Passed (5%) 1.60 1.0 D + 0.6 W Lateral Moment (ft-Ibs) 405 @ mid -span 2290 Passed (18%) 1.60 1.0 D + 0.6 W Total Deflection (in) 0.08 @ mid -span 1 0.74 Passed (L/1075) -- 1.0 D + 0.6 W Bending/Compression 0.50 1 Passed (50%) 1.60 1.0 D + 0.45 W + 0.75 L + 0.75 S • Lateral deflection criteria: Wind (L/120) • Input axial load eccentricity for the design is zero • Applicable calculations are based on NDS. • Member has been designed in flat (plank) orientation with lateral (wind) loads applied to wide strand face. Supports Type Material Top Dbl 2X Spruce -Pine -Fir Base 2X Spruce -Pine -Fir Drawing is Conceptual Max Unbraced Length Comments 7' 4 1/2" Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 10d x 3" Box (End) 3 N/A Base Nails 10d x 3" Box (End) 3 N/A System : Wall Member Type : Column Building Code : IBC 2015 Design Methodology : ASD • Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Vertical Load Tributary Width Dead (0.90) Floor Live (1.00) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Point (lb) N/A 3506 588 3213 4370 Linked from: MB4, Support 1 Lateral Load Location Tributary Width Wind (1.60) Comments 1 - Uniform (PSF) Full Length 4' 24.8 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC AForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 35 / 42 a" O R T CM MEMBER REPORT PASSED 2ND LEVEL, MB5 1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam Overall Length: 11' 8' n All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 4900 @ 4" 11172 (5.50") Passed (44%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 3554 @ 7' 5 1/2" 7619 Passed (47%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Pos Moment (Ft-Ibs) 9560 @ 5' 6 15/16" 17250 Passed (55%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl.(in) 0.093 @ 4'6 3/8" 0.275 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 1 0.141 @ 4' 6 9/16" 1 0.412 1 Passed (L/704) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 8' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Roof Live Snow Total 1 - Trimmer - SPF 5.50" 5.50" 2.41" 1676 2408 531 1892 6507 None 2 - Trimmer - SPF 5.50" 5.50" 2.20" 1462 2408 750 1601 6221 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 11" o/c Bottom Edge (Lu) 8' 11" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Roof Live Snow Vertical Loads Location Tributary Width (0.90) (1.00) (non -snow: 1.25) (1.15) Comments 0 - Self Weight (PLF) 0 to 8' 11" N/A 9.1 -- -- -- 1 - Uniform (PSF) 0 to 8' 11" 7' 6" 12.0 40.0 - Floor 2 - Uniform (PSF) 0 to 8' 11" 4' 12.0 60.0 - 25.0 DECK 3 - Point (lb) 1' N/A 682 - 158 960 Linked from: RB9, Support 2 4 - Point (lb) 5' 9" N/A 829 965 1206 Linked from: RB3, Support 2 5 - Point (lb) 5' 9" N/A 315 158 435 Linked from: RB9, Support 1 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to ,vww.weyerhaeuser.com/wGodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 36 / 42 a" O R T CM MEMBER REPORT PASSED 2ND LEVEL, MB5 1 piece(s) 4 x 8 HF No.2 (Plank) Wall Height: 7' 9" Member Height: 7' 4 1/2" Tributary Width: 5' Design Results Actual Allowed Result LDF Load: Combination Slenderness 25 50 Passed (51%) -- -- Compression (Ibs) 4901 13855 Passed (35%) 1.15 1.0 D + 0.75 L + 0.75 S Plate Bearing (Ibs) 4901 10784 Passed (45%) -- 1.0 D + 0.75 L + 0.75 S Lateral Reaction (Ibs) 270 1.60 1.0 D + 0.6 W Lateral Shear (Ibs) 249 4060 Passed (6%) 1.60 1.0 D + 0.6 W Lateral Moment (ft-Ibs) 499 @ mid -span 2290 Passed (22%) 1.60 1.0 D + 0.6 W Total Deflection (in) 0.12 @ mid -span 0.74 Passed (L/745) 1.0 D + 0.45 W + 0.75 L + 0.75 S Bending/Compression 0.52 1 Passed (52%) 1.60 1.0 D + 0.45 W + 0.75 L + 0.75 S • Lateral deflection criteria: Wind (L/120) • Input axial load eccentricity for this design is 16.67% of applicable member side dimension. • Applicable calculations are based on NDS. • Member has been designed in flat (plank) orientation with lateral (wind) loads applied to wide strand face. Supports Type Material Top Dbl 2X Spruce -Pine -Fir Base 2X Spruce -Pine -Fir Drawing is Conceptual Max Unbraced Length Comments 7' 4 1/2" Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 10d x 3" Box (End) 4 N/A Base Nails 10d x 3" Box (End) 4 N/A System : Wall Member Type : Column Building Code : IBC 2015 Design Methodology : ASD • Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Vertical Load Tributary Width Dead (0.90) Floor Live (1.00) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Point (lb) N/A 1676 2408 531 1892 Linked from: MB5, Support 1 Lateral Load Location Tributary Width Wind (1.60) Comments 1 - Uniform (PSF) Full Length 5' 24.4 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC AForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 37 / 42 a FORTE"M3 MEMBER REPORT 2ND LEVEL, M136 1 piece(s) 4 x 8 HF No.2 PASSED a 0 Overall Length: ? - 2181, All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Y 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1391 @ 4" 7796 (5.50") Passed (18%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 548 @ 1' 3/4" 2538 Passed (22%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 800 @ V 9 1/2" 2823 Passed (28%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.006 @ 1' 9 1/2" 0.097 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.009 @ 1' 9 1/2" 1 0.146 1 Passed (L/999+) 1 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Roof Live Snow Total 1 - Trimmer - SPF 5.50" 5.50" 1.50" 380 968 161 381 1890 None 2 - Trimmer - SPF 5.50" 5.50" 1 1.50" 380 968 161 381 1890 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) T 7" o/c Bottom Edge (Lu) 3' 7" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Floor Live (1.00) Roof Live (non -snow: 1.25) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 3' 7" N/A 6.4 1 - Uniform (PSF) 0 to 3' 7" 7' 6" 12.0 40.0 Floor 2 - Uniform (PSF) 0 to 3' 7" 4' 12.0 60.0 - 25.0 DECK 3 - Uniform (PSF) 0 to 3' 7" 4' 6" 15.0 20.0 25.0 Roof Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 38 / 42 a" O R T CM MEMBER REPORT PASSED 2ND LEVEL, M136 2 piece(s) 2 x 4 HF No.2 Drawing is Conceptual Wall Height: 7' 9" Member Height: 7' 4 1/2" Tributary Width: 3' Design Results Actual Allowed Result LDF Load: Combination Slenderness 30 50 Passed (59%) Compression (Ibs) 1392 2628 Passed (53%) 1.15 1.0 D + 0.75 L + 0.75 S Plate Bearing (Ibs) 1392 4463 Passed (31%) -- 1.0 D + 0.75 L + 0.75 S Lateral Reaction (Ibs) 168 1.60 1.0 D + 0.6 W Lateral Shear (lbs) 154 1680 Passed (9%) 1.60 1.0 D + 0.6 W Lateral Moment (ft-Ibs) 309 @ mid -span 1026 Passed (30%) 1.60 1.0 D + 0.6 W Total Deflection (in) 0.16 @ mid -span 0.74 Passed (L/553) -- 1.0 D + 0.6 W Bending/Compression 0.65 1 Passed (65%) 1.60 1.0 D + 0.45 W + 0.75 L + 0.75 S • Lateral deflection criteria: Wind (L/120) • Input axial load eccentricity for this design is 16.67% of applicable member side dimension. • Applicable calculations are based on NDS. • The column stability factor (Kf = 0.6) applied to this design assumes nailed built-up columns per NDS section 15.3.3. For Weyerhaeuser ELP products refer to the U.S. Wall Guide for multiple -member connection requirements. Supports Type Material Top Dbl 2X Spruce -Pine -Fir Base 2X Spruce -Pine -Fir Max Unbraced Length Comments 7' 4 1/2" Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 10d x 3" Box (End) 2 N/A Base Nails 10d x 3" Box (End) 2 N/A System : Wall Member Type : Column Building Code : IBC 2015 Design Methodology : ASD • Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Vertical Load Tributary Width Dead (0.90) Floor Live (1.00) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Point (lb) N/A 380 968 161 381 Linked from: MB6, Support 1 Lateral Load Location Tributary Width Wind (1.60) Comments 1 - Uniform (PSF) Full Length 3' 25.3 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33% Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC AForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 39 / 42 a FORTE"M3 MEMBER REPORT 2ND LEVEL, MB7 1 piece(s) 4 x 6 HF No.2 PASSED 0 Overall Length: All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 509 @ 0 2126 (1.50") Passed (24%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 263 @ 7" 1925 Passed (14%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 307 @ V 2 1/2" 1625 Passed (19%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.004 @ 1' 2 1/2" 0.081 Passed (L/999+) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.005 @ 1' 2 1/2" 0.121 Passed (L/999+) 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 122 387 509 None 2 - Trimmer - SPF 1.50" 1.50" 1.50" 122 387 509 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 2' 5" o/c Bottom Edge (Lu) 2' 5" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Floor Live (1.00) Comments 0 - Self Weight (PLF) 0 to 2' 5" N/A 4.9 1 - Uniform (PSF) 0 to 2' 5" 8' 12.0 40.0 Floor 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to vww.weyerhaeuser.com/woodproducts/document-library. the product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 40 / 42 a FORTE"M3 MEMBER REPORT 2ND LEVEL, MB8 1 piece(s) 4 x 6 HF No.2 PASSED 0 Overall Length: 1" 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 631 @ 0 2126 (1.50") Passed (30%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 392 @ 7" 2214 Passed (18%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-Ibs) 486 @ V 6 1/2" 1869 Passed (26%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in) 0.011 @ 1' 6 1/2" 0.103 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.013 @ 1' 6 1/2" 1 0.154 1 Passed (L/999+) 1 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Roof Live Snow Total 1 - Trimmer - SPF 1.50" 1.50" 1.50" 82 308 278 424 1092 None 2 - Trimmer - SPF 1.50" 1.50" 1 1.50" 82 308 278 424 1092 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 3' 1" o/c Bottom Edge (Lu) 3' 1" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Floor Live (1.00) Roof Live (non -snow: 1.25) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 3' 1" N/A 4.9 1 - Uniform (PSF) 0 to 3' 1" 2' 12.0 40.0 - - Floor 2 - Uniform (PSF) 0 to 3' 1" 9' - - 20.0 25.0 Roof 3 - Uniform (PSF) 0 to 3' 1" 2' 12.0 60.0 25.0 DECK Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 41 / 42 a" O R T CM MEMBER REPORT PASSED 2ND LEVEL, MB9 2 piece(s) 2 x 12 DF No.2 @ 16" OC 26" 0 Overall Length: 15 3 12' 2" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. ❑2 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2072 @ 2' 7 3/4" 4463 (3.50") Passed (46%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 1374 @ V 6 3/4" 4658 Passed (29%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-Ibs) -3599 @ 2' 7 3/4" 6277 Passed (57%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in) 0.090 @ 0 0.200 Passed (2L/706) 1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl.(in) 0.134 @ 0 0.265 1 Passed (2L/472) 1 1.0 D + 0.75 L + 0.75 S (Alt Spans) TJ-Pro'"" Rating N/A N/A I N/A I N/A • Deflection criteria: LL (L/480) and TL (L/240). • Overhang deflection criteria: LL (2L/0.2") and TL (2L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. • No composite action between deck and joist was considered in analysis. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Stud wall - SPF 3.50" 3.50" 1.62" 743 858 914 2515 Blocking 2 - Stud wall - SPF 3.50" 2.25" 1.50" -7 342/-75 -161 z 3 1 1/4" Rim Board • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 152" o/c Bottom Edge (Lu) 13' 9" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Snow Vertical Loads Location (Side) Spacing (0.90) (1.00) (1.15) Comments 1 - Uniform (PSF) 0 to 153" 16" 12.0 40.0 - Default Load 2 - Point (lb) 0 N/A 61 306 128 3 - Point (lb) 0 N/A 431 625 Linked from: RB13, Support 1 System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASO Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jasper Baarbe Structural Design Associates (425) 339-0293 jasper@sdaeverett.com 4/15/2022 5:53:48 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: 9508 Page 42 / 42 KUNKLE RESIDENCE I April 14, 2022 1 SDA Job # 9508 BEAM ASD REACTIONS (POSTIIVE LOADS ACTS IN THE DOWNWARD DIRECTION) BEAM ID DL k L k SL k WL k E k R MAX R MIN SUPPORT RB1 0.266 0.421 ± ± 0.69 0.16 RAFTER RB2 [11 0.203 0.238 ± ± 0.44 0.12 MSC4 RB2 [21 0.699 1.002 ± ± 1.70 0.42 46 RB2 [31 0.409 0.616 ± ± 1.03 0.25 46 RB3 [11 0.122 0.186 ± ± 0.31 0.07 MSC4 RB3 [21 0.829 1.206 ± ± 2.04 0.50 44 RB3 [31 0.823 1.234 ± ± 2.06 0.49 44 RB4 4.826 6.497 ± ± 11.32 2.90 3.5x9.5 LSL RB5 0.726 1.031 ± ± 1.76 0.44 2-2x4 RB6 0.172 0.234 ± ± 0.41 0.10 2-2x4 RB7 [11 1.491 1.986 ± ± 3.48 0.89 48 RB7 [21 3.743 5.018 ± ± 8.76 2.25 3.5x9.5 LSL RB8 0.346 0.436 ± ± 0.78 0.21 2-2x4 RB9 0.682 0.96 ± ± 1.64 0.41 2-2x4 RB10 0.522 0.639 ± ± 1.16 0.31 6x6 PT RB11 0.229 0.194 ± ± 0.42 0.14 46 RB12 0.266 0.384 ± ± 0.65 0.16 2-2x RB13 0.431 0.625 ± ± 1.06 0.26 46 RB14 0.914 1.312 ± ± 2.23 0.55 46 RB15 0.132 0.204 ± ± 0.34 0.08 6x6 PT RB16 0.091 0.11 ± ± 0.20 0.05 2-2x4 RB17 0.859 1.25 ± ± 2.11 0.52 2-2x4 RB18 0.398 0.583 ± ± 0.98 0.24 2-2x4 RB19 0.277 0.391 ± ± 0.67 0.17 2-2x4 RB20 0.333 1.126 ± ± 1.46 0.20 6x6 PT RB21 0.128 0.206 ± ± 0.33 0.08 RB20 MB1 0.069 0.343 0.143 ± ± 0.43 0.04 DECK JOIST MB2 [11 0.221 1.1 0.428 ± ± 1.37 0.13 6x6 PT MB2 [21 0.689 2.944 1.227 3.82 0.41 6x6 PT MB3 0.175 0.531 ± ± 0.71 0.11 2-2x4 MB4 3.506 0.588 4.37 ± ± 7.88 2.10 48 MB5 2.411 2.408 2.924 ± ± 6.41 1.45 48 MB6 0.38 0.968 0.381 ± ± 1.39 0.23 2-2x4 MB7 0.122 0.387 ± ± 0.51 0.07 2-2x4 MB8 0.082 0.308 0.424 ± ± 0.63 0.05 2-2x4 MB9 0.743 0.858 0.914 ± ± 2.07 0.45 2x4 FOUNDATION DESIGN - ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF MB2 [21 0.689 2.944 1.227 3.82 0.41 AREA = 2.544833 SF B = W = 1.595253 ft <---- USE 24248 RB14 0.914 1.312 ± ± 2.23 0.55 RB13 0.431 0.625 ± ± 1.06 0.26 MB9 0.743 0.858 0.914 ± ± 2.07 0.45 TOTAL 2.088 0.858 2.851 4.94 1.25 AREA = 3.292667 SF B = W = 1.814571 ft <---- USE 24248 RB13 0.431 0.625 ± ± 1.06 0.26 [El BEAM 0.84 2.8 ± ± 3.64 0.50 HDU14 1.54 1.1 ± 20.885 ± 2.606 14.07 -11.61 TOTAL 2.811 3.9 0.625 6.71 1.69 AREA = 4.474 SF B = W = 2.115183 ft <---- USE 30xl6 VOL. REQ = 77.38 CF SLAB VOL = 49.5 CF STRIP FT'G = 49.875 CF TOTAL = 99.375 CF MB4 3.506 0.588 4.37 ± ± 7.88 2.10 TOTAL 3.506 0.588 4.37 ± ± 7.88 2.10 AREA = 5.250667 SF B = 1.33 ft. L_EFF. = 4 ft. AREA_EFF = 5.32 SF <----- USE [El 1608 MB5 1.68 2.41 1.89 ± ± 4.90 1.01 HDU8 ± 8.18 ± 8.61 6.03 -6.03 TOTAL 1.68 2.41 1.89 ± 8.18 ± 8.61 9.42 -5.02 AREA = 6.28 SF B = 1.33 ft. L_EFF. = 5.00 ft. AREA_EFF = 6.65 SF UT% = 94% < 105% <---- USE [E} 1608 MB3 0.175 0.531 ± ± 0.71 0.11 HDU4 ± 3.415038 ± 4.465414 3.13 -3.13 TOTAL 0.18 0.53 0.00 ± 3.42 ± 4.47 3.30 -3.02 AREA = 2.20 SF B = 1.33 ft. L_EFF. = 5.00 ft. AREA_EFF = 6.65 SF UT% = 33% < 105% <---- USE [E} 1608 Project Title: Engineer: Project ID: SDA#9508 Project Descr: Pole FootingEmbedded in Soil File:9508.ec6 Software copyright ENERCALC, INC. 1983-2020, BuiId:12.20.8.24 KW-06014008 Structural Design Associate; DESCRIPTION: EMBED. POST Code References Calculations per IBC 2018 1807.3, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Pole Footing Shape Circular Pole Footing Diameter ........... 30.0 in Calculate Min. Depth for Allowable Pressures No Lateral Restraint at Ground Surface Allow Passive .................. 250.0 pcf Max Passive ................... 1,500.0 psf Controlling Values Governing Load Combination : +D+0.70E Point Load Lateral Load 1.917 k Soil Surface No lateral restraint q Moment 1.917 k-ft iv NO Ground Surface Restraint \ Pressures at 1/3 Depth 50 Actual 425.445 psf Allowable 426.394 psf Minimum Required Depth 5.125 ft Footing Base Area 4.909 ft^2 Maximum Soil Pressure 0.5669 ksf Applied Loads Lateral Concentrated Load (k) Lateral Distributed Loads (klf) Vertical Load (k) D : Dead Load k k/ft 0.6310 k Lr : Roof Live k k/ft k L : Live k k/ft 1.230 k S : Snow k k/ft 1.639 k W : Wind 1.205 k k/ft k E : Earthquake 2.739 k k/ft k H : Lateral Earth k k/ft k Load distance above TOP of Load above ground surface ground surface 1.0 ft ft BOTTOM of Load above ground surface ft Load Combination Results Forces @ Ground Surface Required Pressure at 1/3 Depth Soil Increase Load Combination Loads - (k) Moments - (ft-k) Depth - (ft) Actual - (psf) Allow - (psf) Factor D Only 0.000 0.000 0.13 0.0 0.0 1.000 +D+L 0.000 0.000 0.13 0.0 0.0 1.000 +D+S 0.000 0.000 0.13 0.0 0.0 1.000 +D+0.750L 0.000 0.000 0.13 0.0 0.0 1.000 +D+0.750L+0.750S 0.000 0.000 0.13 0.0 0.0 1.000 +D+0.60W 0.723 0.723 3.38 274.0 274.0 1.000 +D+0.750L+0.450W 0.542 0.542 3.00 241.2 241.3 1.000 +D+0.750L+0.750S+0.450W 0.542 0.542 3.00 241.2 241.3 1.000 +0.60D+0.60W 0.723 0.723 3.38 274.0 274.0 1.000 Project Title: Engineer: Project ID: SDA#9508 Project Descr: Pole FootingEmbedded in Soil File:9508.ec6 Software copyright ENERCALC, INC. 1983-2020, BuiId:12.20.8.24 KW-06014008 Structural Design Associate� DESCRIPTION: EMBED. POST +D+0.70E 1.917 1.917 5.13 425.4 426.4 1.000 +D+0.750L+0.750S+0.5250E 1.438 1.438 4.50 373.0 373.8 1.000 +0.60D+0.70E 1.917 1.917 5.13 425.4 426.4 1.000 Project Name/Number : 9508 RetainPro (c) 1987-2019, Build 11.20.03.31 License : KW-06060593 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 License To: STRUCTURAL DESIGN ASSOCIATES Criteria Soil Data 111 Retained Height = 5.00 ft Wall height above soil = 0.00 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 12.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel = 40.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Design Summary Wall Stability Ratios Overturning = 1.82 OK Sliding = 1.60 OK Total Bearing Load = 1,551 Ibs ...resultant ecc. = 6.59 in Allow Soil Bearing = 1,500.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 250.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 0.00 pcf FootingIlSoil Friction = 0.350 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Tor = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) Soil Pressure @ Toe = 1,393 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,950 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 14.2 psi OK Footing Shear @ Heel = 10.6 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 685.2 Ibs less 100% Passive Force = - 555.6 Ibs less 100% Friction Force = - 542.9 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Load Factors Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 2018,AC1 1.200 1.600 1.600 1.000 1.000 Stem Construction Design Height Above Ftc ft = Wall Material Above "Ht" _ Design Method = Thickness = Rebar Size = Rebar Spacing = Rebar Placed at = Design Data fb/FB + fa/Fa = Total Force @ Section Service Level Ibs = Strength Level Ibs = Moment.... Actual Service Level ft-# _ Strength Level ft-# _ Moment..... Allowable = Shear..... Actual Service Level psi = Strength Level psi = Shear..... Allowable psi = Anet (Masonry) in2 = Rebar Depth 'd' in = Masonry Data f'm psi = Fs psi = Solid Grouting = ModularRatio'n' _ Wall Weight psf = Short Term Factor = Bottom Adjacent Footing Load Adjacent Footing Load = 1,000.0 Ibs Footing Width = 2.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 2.50 ft Footing Type Square Footing Base Above/Below Soil = 0.0 ft at Back of Wall Poisson's Ratio = 0.300 Stem OK 0.00 Concrete LRFD 6.00 # 4 12.00 Center 0.932 877.4 1,591.3 1,705.6 24.4 75.0 3.00 75.0 Equiv. Solid Thick. _ Masonry Block Type = Medium Weight Masonry Design Method = ASD Concrete Data fc psi = 2,500.0 Fy psi = 40,000.0 Project Name/Number : 9508 RetainPro (c) 1987-2019, Build 11.20.03.31 License: KW-06060593 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 License To: STRUCTURAL DESIGN ASSOCIATES Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.1978 in2/ft (4/3)' As : 0.2638 in2/ft Min Stem T&S Reinf Area 0.720 in2 200bd/fy : 200(12)(3)/40000 : 0.18 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.144 in2/ft 0.0018bh : 0.0018(12)(6) : 0.1296 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of: Required Area : 0.1978 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area : 0.2 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area: 0.6096 in2/ft #6@ 36.67 in #6@ 73.33 in Footing Data Footing Design Results Toe Width = 0.92 ft Toe Heel Heel Width = 1.67 Factored Pressure = 1,950 0 psf Total Footing Width = 2.58 Mu': Upward = 8,481 78 ft-# Footing Thickness = 8.00 in Mu': Downward = 1,271 574 ft-# Mu: Design = 601 497 ft-# Key Width = 8.00 in Actual 1-Way Shear = 14.21 10.56 psi Key Depth = 8.00 in Allow 1-Way Shear = 75.00 75.00 psi Key Distance from Toe = 0.92 ft Toe Reinforcing = # 4 @ 13.88 in fc = 2,500 psi Fy = 40,000 psi Heel Reinforcing = # 4 @ 13.88 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min. As % = 0.0018 Footing Torsion, Tu = 0.00 ft-Ibs Cover @ Top 2.00 @ Btm: 3.00 in Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: #4@ 13.88 in, #5@ 21.52 in, #6@ 30.55 in, #7@ 41.66 in, #8@ 54.86 in, #9@ 6 Heel: #4@ 13.88 in, #5@ 21.52 in, #6@ 30.55 in, #7@ 41.66 in, #8@ 54.86 in, #9@ 6 Key: phiMn = phi'5'lambda'sgrt(fc)'Sm Min footing T&S reinf Area 0.45 in2 Min footing T&S reinf Area per foot 0.17 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 13.89 in #4@ 27.78 in #5@ 21.53 in #5@ 43.06 in #6@ 30.56 in #6@ 61.11 in Project Name/Number : 9508 RetainPro (c) 1987-2019, Build 11.20.03.31 License : KW-06060593 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 License To: STRUCTURAL DESIGN ASSOCIATES Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# HL Act Pres (ab water tbl) 561.9 1.89 1,061.5 Soil Over HL (ab. water tbl) 641.7 2.00 1,283.3 HL Act Pres (be water tbl) Soil Over HL (bel. water tbl) 2.00 1,283.3 Hydrostatic Force Watre Table Buoyant Force = Sloped Soil Over Heel = Surcharge over Heel = 72.1 2.83 204.3 Surcharge Over Heel = 46.7 2.00 93.3 Surcharge Over Toe = Adjacent Footing Load = 162.8 2.00 325.6 Adjacent Footing Load = 51.1 2.72 139.1 Axial Dead Load on Stem = Added Lateral Load = " Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = 0.46 = Surcharge Over Toe = Stem Weight(s) = 375.0 1.17 437.5 Earth @ Stem TransitionE _ Total = 685.2 O.T.M. = 1,404.9 Footing Weight = 258.3 1.29 333.7 Key Weight = 66.7 1.25 83.3 Resisting/Overturning Ratio = 1.82 Vert. Component = Vertical Loads used for Soil Pressure = 1,551.1 Ibs Total = 1,551.1 Ibs R.M.= 2,556.8 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.075 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil.