APPROVED BLD FIR BLD2022-1276+Architectural_Plan+9.23.2022_9.22.21_AM+31256933'-0" 2'-0"2'-0" FRONT ENTRY 100 SF HEATED STORAGE 112 SF SIDE ENTRY 8'-0"8'-0" 2' - 3 1 2" 21 ' - 5 " DN BATHROOM 2'-01 2" 2' - 0 1 2" 3' - 0 " m i n . 335 SF CL 1'-4" 2'-6"3'-8" 9' - 6 " CL3' - 0 " 2'-41 2" KITCHEN 24DW SLEEPING AREA 8'-101 2" 6'-0"7'-71 2" 3'-91 2" 3'-6" 41 2" 4'-0" 61 2" A 101 A A A B C C H D A F2 E 102 103 103 104 201 202 203 105 106 107 2' - 8 " 1' - 4 " GARAGE 433 SF 22'-41 2"11'-21 2" SD H CM SD CM SD CM SD 15'-11 2" 4'-6" 5' - 2 " 5' - 0 " 6'-0" 16'-0" 33'-7" 6' - 1 0 " 6' - 1 0 " 10 ' - 4 1 2" (P) GAS METER 7' - 0 " 3'-101 2" D E FF1G 7' - 4 1 2" 8' - 7 1 2" 8'-71 2" 9'-51 2"2'-41 2" 6" FULL EXT OR INT WALL HALF HT INT WALL. (CONC SLAB) (CONC SLAB) SLOPED FOR DRAINAGE 3" (CONC SLAB) (LVP) (LVP) (LVP) (TILE) 4' - 1 " 2' - 0 " 912" SD 5' - 0 " LINEN CLOSET CLOSET COAT CLOSET LAUNDRY 41 2"41 2"11'-21 2" 13 ' - 4 " LIVING/ DINING AREA 3' - 0 " 3' - 0 " 3' - 1 0 " 3' - 1 0 " 5' - 9 1 2" 3' - 8 1 2" 4'-41 2"UP 4' - 9 " 2 C 130 SF 91 SF 53 SF 41 SF HALL A1.0 DRAWN BY: vs DATE:08.17.2022 SHEET TILE: Floor Plans PROJECT ADDRESS: 7606 206th St SW Unit C Edmonds, WA 98026 Edmonds Project No: OWNERS NAME: Rebecca West & Damian John PHASE: Permit Submittal Set Cycle REVISIONS: Edmonds APPROVAL STAMP 1 AD STUDIO LLC Val Sporleder Designer 206.604.1351 val@1ADstudio.com GENERAL CONTRACTOR: JoDaVue LLC 7606 206th St SW Edmonds,WA 98026 Sheet size: 24" x 36" SCALE: 1/4" = 1'-0"2 FLOOR PLAN - STUDIO APT SCALE: 1/4" = 1'-0"1 FLOOR PLAN - GARAGE WINDOW SCHEDULE MARK PG. NO. - DWG NO.QTY.TYPE UNIT SIZE W x H AREA (SF)MFG MATERIAL MODEL #U-FACTOR NOTES A A1.0 - 1&2 5 FIXED 1'-6" x 6'-0"45 SF Milgard Vinyl Tuscany Series, V400, TYP.0.24 BLACK FOR EXTERIOR COLOR - All vertical fenestraction must have a U-Factor of 0.24 to obtain Option 1.1 of R402.1.1 Energy Credits. B A1.0 - 1 1 CASEMENT 2'-6" X 4'-0"10 SF C A1.0 - 2 3 CASEMENT 2'-6" X 4'-2"30.5 SF Window 'C' in sleeping area is an egress window. Confirm window has a net clear opening of not less than 5.7 SF, a min. net clear height of 24" & a min. net clear width of 20". Sill height no more than 44" above finish floor. D A1.0 - 2 2 FIXED 4'-0" X 4'-2"33 SF E A1.0 - 2 2 CASEMENT 2'-6" X 5'-0"37.5 SF Sill height must be at 24" or above or fall protection is required per IRC 312.2.1. When sill height is less than 36" above an adjacent walking surface this is considered a hazardous location per IRC 308.4.6. Tempered glass required. F A1.0 - 2 3 CASEMENT 1'-6" X 3'-6"16.5 SF F-1 has Obscure glass. G A1.0 - 2 1 FIXED 2'-6" X 3'-6"9 SF H A1.0 -2 1 FIXED 5'-0" X 4'-2"21 SF 18 TOTAL 202.5 SFDOOR SCHEDULE MARK PG. No. - Dwg No.TYPE SIZE W x H U-FACTOR NOTES 101 A1.0 - 1 EXTERIOR 3'-0" x 6'-8" 0.24 Exterior Door with glazing (temp.) and min 1 2" throw bolt lock. On ground floor, not included in Heat Sizing Worksheet 102 A1.0 - 1 EXTERIOR 3'-0" x 6'-8" 0.24 Exterior Door with glazing (temp.) and min 1 2" throw bolt lock. On ground floor. 103 A1.0 - 1 OVERHEAD GARAGE 7'-0" x 8'-0"xx QTY (2) automatic garage doors. UNHEATED SPACE 104 A1.0 - 1 GARAGE TO INTERIOR 2'-6" x 6'-8" 0.30 Solid wood doors not less than 1-3/8 inches in thickness, solid or honeycomb-core steel doors not less than 1-3/8 inches thick, or 20-minute fire-rated doors, equipped with a self-closing or automatic-closing device. 105 A1.0 - 1 INTERIOR 2'-6" X 6'-8"Coat closet 106 A1.0 - 1 INTERIOR 3'-0" X 6'-8"Laundry closet. 107 A1.0 - 1 INTERIOR 2'-6" X 6'-8"Heated storage door 201 A1.0 - 2 INTERIOR 2'-6" x 6'-8"Bathroom. Include locking hardware 202 A1.0 - 2 INTERIOR 2'-6" x 6'-8"Linen closet. Provide a vent in wall above door for whole house fan. 203 A1.0 - 2 INTERIOR 5'-0" x 6'-8"Sleeping area closet. Bi-Pass doors (Qty. 2) 1. All window U-Values to be NFRC certified 2. Glass to be tempered (SG) where required per SRC R308.4 6. Windows and doors shall limit infiltration per WSECR402.4 4. Windows Max. U-value- 0.24 TYP. for energy credits. 5. All operable windows to have screens and be controllable and securable. 1. All exterior door U-values to be NFRC certified Interior dimensions to face of finish, TYP. U.N.O. Exterior dimension to center of doors and windows. * For Mechanical, Electrical & Plumbing placement and general notes; Please see MEP Plan A5.1. A5 . 0 1 Fire Rated - 1- 3/8" solid core or 20 minute door.See Door schedule for details A5.0 2 3. Windows and doors must be installed according to the fenestration manufacturer’s instructions and flashing must be in accordance with Section R703.4 ACCESS TO UNDER STAIRS. 16" X 24" MIN. TEMPERED GLASS 7. Reference IRC 2018 R310 Emergency Escape and Rescue Openings 2. Glass to be tempered (SG) where required per SRC R308.4 A5.0 2 FRAMING: Lumber used shall be checked for any defects and imperfections that may compromise the purpose it is intended to serve. Provide minimum 30# building paper or other approved sill seal or gasket under all bearing plates. All bearing plates shall be pressure treated and bolted to foundation per structural. Provide solid blocking under all bearing walls perpendicular to joists and other bearing points not otherwise provided with support. All floor joists and rafters to have solid blocking at ends of exposed spans and at mid-span, if span is greater than 10 feet. Fire blocking required in all wood framed construction at the locations listed in R302.11 All wood in contact with concrete shall be pressure treated or provide a minimum of 1 2" air space. Stagger joints of plywood panels and provide blocking at joints. All plywood shall have surface grain perpendicular to supports. All nailing to conform to nailing schedule. See Structural Plans and Notes. Performance specification items must be supplied by subcontractor, from any manufacturer that meets the specification criteria. THERMAL AND MOISTURE PROTECTIONS: Provide WRB on all exterior walls and install per manufacturer's installation instructions. Fully wrap WRB to interior at all openings. Provide continuous metal flashing at all joints between walls and roofs, vertically on all corners where wall meets wall, and horizontally over joint between wall sheathing and concrete footer. Flashing to be overlapped with WRB. Insulate building envelope per plans and follow all requirements to meet prescriptive energy requirements and the additional requirements indicated on A5.0 & A5.1 to fulfill energy credit requirements. Air sealing required to meet minimum air changes per hour for the Efficient Building Envelope Energy Option chosen. See A5.1. All window flashing shall be applied in a shingle style method and per window manufacturers installation instructions. ALL SMOKE DETECTORS AND CARBON MONOXIDE ALARMS DEVICES SHALL BE INTERCONNECTED in such a manner that the actuation of one alarm will activate all of the alarms in the dwelling Unit, TYP. A5 . 0 1 CONTINUOUS HANDRAIL See A5.0 for FIRE SEPARATION Details. Install 1/2" Gypsum board on walls and 5/8" Type X on ceiling to completely separate garage from dwelling See A5.1 for Exterior Lighting and Stair Lighting RECEIVED Sep 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GUARDRAILS SHALL BE MIN. 36” IN HEIGHT WHERE THE ADJACENT SURFACE OR GRADE IS 30” OR MORE BELOW. RAILINGS SHALL BE SPACED TO NOT ALLOW THE PASSAGE OF A 4” SPHERE. IRC R312.1 Existing side sewer to be redirected to exterior of proposed unit C or should SS stay under the Proposed BLD the SS pipe need to meet the requirements of the 2018 UPC Table 701.2 City Of Edmonds Building Department Work Address Owner Approved Date Building Official Permit Number NEW STUDIO APT 7606 206TH ST SW KONASIEWICZ 03/28/2023 BLD2022-1276 03-03-2023 PLAN REVIEW NOTES: APPROVED DFM BURT Approved DFM Chris Burt South County Fire Date: 03/03/2023 A separate plumbing permit is required for this project. Please obtain a plumbing permit from the City of Edmonds. The following documentation shall be available on site for the building inspector: COE APPROVED ARCHITECTURAL PLAN SET COE APPROVED STRUCTURAL PLAN SET COE REVIEWED CALCULATION PACKET ENERGY CREDIT WORKSHEET SITE PLAN CIVIL PLAN CITY OF EDMONDS BUILDING DEPARTMENT 2021 APPROVED PLANS MUST BE ON JOB SITE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE Donovan Akau X 6' - 8 " H D R H T . 10 ' - 5 " 10 ' - 0 " TEMP TEMP 7606-C 1'-0" TEMP TEMP TEMP TEMP T.O. SLAB AVG GRADE 24 ' - 0 " 6' - 8 " 7' - 0 " T.O. FINISH FOOR T.O. PLATE +25' MAX RIDE ELEVATION 25' MAX ROOF HEIGHT AT 3:12 PITCH. +5' for 4:12 AND ABOVE 100.36' 100.86' 121.28' 124.86' 7' - 6 " H D R H T 111.28' 3' - 7 " 6" 1'-0" 3" 25 ' - 0 " TEMP 125.36' 7' - 0 " H D R H T EGRESS 6' - 1 0 " H D R H T . R3 ' - 0 " R3'-0 " R3' - 0 " 10'-0" 6" 6' - 1 0 " H D R H T 7' - 0 " H D R H T 3'-0" MIN. GAS6'-0" TEMP A3.0 DRAWN BY: vs DATE: 08.20.2022 SHEET TILE: Exterior Elevations PROJECT ADDRESS: 7606 206th St SW Unit C Edmonds, WA 98026 Edmonds Project No: OWNERS NAME: Rebecca West & Damian John PHASE: Permit Submittal Set Cycle REVISIONS: Edmonds APPROVAL STAMP 1 AD STUDIO LLC Val Sporleder Designer 206.604.1351 val@1ADstudio.com GENERAL CONTRACTOR: JoDaVue LLC 7606 206th St SW Edmonds,WA 98026 Sheet size: 24" x 36" SCALE: 1/4" = 1'-0"1 SOUTH ELEVATION SCALE: 1/4" = 1'-0"2 EAST ELEVATION (Main Entrance) HARDI LAP 5-1/4" REVEAL 30 YR ASPHALT SHINGLES. CONFIRM VENTING GUIDELINES FOR ROOFING MATERAL 4" CORNER BOARD SCALE: 1/4" = 1'-0"3 NORTH ELEVATION SCALE: 1/4" = 1'-0"4 WEST ELEVATION 6" TONGUE AND GROOVE CEDAR SIDING, VERTICAL OVERHEAD GARAGE DOORS 6" GUTTER TYP. Connected to tightlined down spout SPLASH BLOCK, TYP. 2x12 BELLY BAND 2x10 FASCIA DOWNSPOUT, TYP. ALL OUTDOOR INTAKE AND EXHAUST OPENING LOCATIONS SHALL BE IN ACCORDANCE WITH R303.5 HEADER HT. FOR 2ND FLOOR WINDOWS ON EAST ELEVATION ONLY. (TO ACCOMMODATE KITCHEN WINDOW SILL HT.) SIDING AT EQUIDISTANCE 4" CONC SLAB LANDING RECEIVED Sep 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 80 " M I N C L R 3' - 0 " M I N . 3' - 0 " M I N . 7- 3 / 4 " M A X 10" MIN. 9' - 0 " 6" m i n . 2' - 0 " m i n . 12 " A5.0 DRAWN BY: vs DATE: 08.10.2022 SHEET TILE: Floor Plans PROJECT ADDRESS: 7606 206th St SW Unit C Edmonds, WA 98026 Edmonds Project No: OWNERS NAME: Rebecca West & Damian John PHASE: Permit Submittal Set Cycle REVISIONS: Edmonds APPROVAL STAMP 1 AD STUDIO LLC Val Sporleder Designer 206.604.1351 val@1ADstudio.com GENERAL CONTRACTOR: JoDaVue LLC 7606 206th St SW Edmonds,WA 98026 Sheet size: 24" x 36" SCALE: 1/4" = 1'-0"1 SECTION: East -West SCALE: 3/4" = 1'-0"3 FOOTING DETAIL - SLAB ON GRADE SCALE: 3/4" = 1'-0"4 ROOF INSULATION DETAIL - JOIST VAULTED CEILING FINISHED GRADE SHOULD FALL A MIN. OF 6" WITHIN THE FIRST 10' PT 2x2 NAILER MAY BE PLACED AT THE FINISH FLOOR ELEVATION PER R402.2.9 R-10 RIGID FOAM AT SLAB EDGE TO A DEPTH OF 2' AND UNDER ENTIRE SLAB FOOTING PER STRUCTURAL 6 MIL VAPOR BARRIER. GRAVEL @ BASE PER STRUCTURAL FOOTING DRAIN IF NEEDED 2X RAFTER PER STRUCTURAL ROOF SHEATHING PER STRUCTURAL UNDERLAYMENT PER ROOF SHINGLE MANUFACTURER RECOMMENDATION 30-YEAR ASPHALT ROOF CLOSED CELL (AIR IMPERMEABLE) SPRAY FOAM INSULATION IN RAFTER VAULTED CEILING. APPLIED DIRECTLY TO THE UNDERSIDE OF THE SHEATHING AND PER MANUFACTURER INSTALLATION SPECIFICATIONS AND BY A CERTIFIED INSTALLER TO A DEPTH TO ACHIEVE R- 38 AND TO A DEPTH TO BE USED AS AIR BARRIER. EXTENDED TO OUTER EDGE OF TOP PLATE. THICKNESS DOCUMENTED PER WSEC R303.1.1.1. AIR SEALING REQUIRED AT THE JUNCTION OF THE TOP PLATE AND TOP OF THE EXTERIOR WALL FASCIA BOARD WRB OVER DRIP EDGE FLASHING RAFTER BLOCKING 1 2" GWB FOOTING / FOUNDATION DETAIL PER STRUCTURAL 4" CONC. SLAB ON GRADE. PER STRUCTURAL. IRC R702.7 VAPOR RETARDER: KRAFT-FACED FIBERGLASS BATTS. R-10 INSULATION AT ALL HEADERS & RIM JOISTS. HEADER SIZE PER STRUCTURAL. R-21 MIN. INSULATION IN ALL EXTERIOR WALL CAVITIES. 2X RAFTERS PER STRUCTURAL SPRAY FOAM INSULATION MUST EXTEND OVER TOP OF PLATE - SEE DETAIL DWG 4 FOOTING DRAIN R-10 UNDER ENTIRE SLAB. SEE DETAIL DWG 2. GRAVEL BASE PER STRUCTURAL CLASS 1 VAPOR RETARDER RIDGE BEAM PER STRUCTURAL 1 2" GWB UNDER STAIRS IN OPEN AND ENCLOSED SPACE, TYP. SHEATHING PER STRUCTURAL I-JOIST SIZING AND SPACING PER STRUCTURAL SLAB ON GRADE PER STRUCTURAL. TURNED DOWN, THICKENED EDGE AT GARAGE OPENING. PER STRUCTURAL. IRC R702.7 CLASS II VAPOR RETARDER REQUIRED ON HEATED SIDE OF INSULATED PARTITION WALLS. KRAFT FACED BATTS TO BE USED. R-30 INSULATION FIBERGLASS BATTS IN ALL JOISTS BAYS OVER GARAGE REQUIRED. R-30 INSULATION BATTS IN JOIST BAYS OVER HEATED STORAGE SPACE RECOMMENDED. PER R402.2.7 FLOOR FRAMING CAVITY INSULATION SHALL BE INSTALLED TO MAINTAIN PERMANENT CONTACT WITH THE UNDERSIDE OF THE SUB FLOOR DECKING R-21 MIN. INSULATION IN ALL EXTERIOR WALL CAVITIES AND WALL BTWN GARAGE AND ALL HEATED SPACES. R-10 UNDER ENTIRE SLAB & 2' DOWN TO TOP OF FOOTING. SEE DETAIL DWG 2. IRC R702.7 CLASS II VAPOR RETARDER REQUIRED ON GARAGE CEILING. SCALE: 1/4" = 1'-0"2 SECTION: North-South OPENINGS AND PENETRATION THROUGH THE WALL AND CEILINGS BTWN THE DWELLING UNIT AND GARAGE SHALL BE IN ACCORDANCE SECTIONS R302.5.1 - R302.5.3 5 8" TYPE X GYPSUM REQUIRED FOR GARAGE CEILING PER R302.6 FIRE BLOCKING PER R302.11 1 2" GWB ON ALL INTERIOR SIDE OF GARAGE WALLS AND ANY SUPPORTING MEMBERS PER R302.6 FLOOR ASSEMBLIES FLOOR OVER UNHEATED SPACE (GARAGE): - FINISH FLOOR - SHEATING PER STRUCTURAL - TJIs PER STRUCTURAL - R-30 KRAFT FACED BATT INSULATION - 5 8" TYPE X GWB FLOOR OVER HEATED SPACE: - FINISH FLOOR - STRUCTURAL SHEATHING - R-30 BATT INSULATION (Recommended) - TJIs PER STRUCTURAL - 1 2" GWB WALL ASSEMBLIES EXTERIOR WALL - HEATED AND UNHEATED SPACE: - CLADDING PER ELEVATIONS - WRB LAYERS - SHEATHING PER STRUCTURAL - 2x6 WOOD STUDS - R-21 KRAFT FACED BATT INSULATION - 1 2" GWB INTERIOR WALLS 2x4: - 1 2" GWB - 2x4 WOOD STUDS - 1 2" GWB INTERIOR WALLS 2x6: - 1 2" GWB - 2x6 WOOD STUDS - R-21 KRAFT FACED BATT INSULATION - 1 2" GWB 6" SS GUTTER, TYP. RIM BOARD PER STRUCTURAL CONTINUOUS HANDRAIL (OPPOSITE WALL) WITH A SPACE NOT LESS THAN 1-1/2" BTWN RAIL AND WALL. HANDRAIL SHALL NOT BE LESS THAN 1-1/4" AND NOT MORE THAN 2" AND PROJECT NO MORE THAN 4-1/2" INTO STAIR WELL RAILING MEMBERS (AND RISERS) SHALL BE CLOSE ENOUGH TO PREVENT PASSAGE OF A 4" SPHERE. AIR SEALING REQUIRED AT THE JUNCTION OF THE SILL PLATE AND FOUNDATION WALL GRADE SHALL SLOPE AWAY FROM FOUNDATION WALLS MIN. 6 INCHES WITHIN THE FIRST 10 FEET, TYP. PROVIDE ARTIFICIAL LIGHT IN STAIR WELLS PER R303.6 CLOSE ENOUGH TO PREVENT PASSAGE OF A 6" SPHERE. STAIRWELL BATHROOM HEATED STRG ENTRY HALL SLEEPING AREA KITCHEN HALLWAY HEATED STRGGARAGE SILL SEAL BTWN TOP OF CONC AND PT SILL PT PLATE. DRIP EDGE FLASHING LIVING ROOM HALLWAY RIDGE BEAM PER STRUCTURAL VAULTED CEILING **Not required per code for slab on grade but recommended. 4" PERFORATED DRAIN PIPE IN WASHED GRAVEL OR CRUSHED ROCK (Min. one sieve size larger than the opening or perforation) GUARD AND HANDRAIL TO SUSTAIN 200lb LOAD. GUARD BALUSTERS TO SUSTAIN 50psf LOAD. RECEIVED Sep 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W/D PKG #3 9'-0" PKG #4 9'-0" ENTRY (HEATED) 9'-0"DN BATHROOM GAS EL E C . PA N E L LIVING CLCL KITCHEN UNIT C STUDIO APT (661 SF) BEDROOM SD CM H SD CM SD SD CM SD D GF C I GFCI GFCI GFCI GFCI GFCI GFCI GF C I D D P Final placement by homeowner $ $3 D P 500w $$ $4 $4 $4$3 $3 $ $ $ ALL LIGHTS ON THIS SWITCH TO BE PHOTOCELL AND SWITCHED PHOTOCELL AND SWITCHED MOTION SENSOR (P) GAS METER WITH EMERGENCY SHUT OFF. Energy Credit Option 3.5 - Ductless mini-split heat pump system with a minimum HSPF of 10.0 SIZED FOR 660 SF. Heat Pump- Daikon MSX18 with HSPF of 10. ** HVAC installer shall decide on final placement but shall be at least 3' from the property line. CONDENSER AIR HANDLER (P) ELECTRICAL PANEL WITH ELECTRIC SERVICE DISCONNECT TILE - HEATED DW 1 of 2 Electric resistance wall heaters. Table 406.3, Option 3.6, Footnote 2: Alternative heat source sized to a max. .5w/SF or 500w whichever is greater. Install per manufacturers installation instructions. Include one programmable thermostat. To provide heating/cooling to the main living areas. steam shower 220 Energy Option Credit 5.2 - GAS ON DEMAND WATER HEATER: Noritz NR-98-DVC-NG NR-98 5.6 GPM @ 60* F. rise. .83UEF. Install per manufacturers installation instructions. ** Sources of ignition for gas hot water tank to be located a minimum of 18" above finished floor, or labeled FVIR. ** Accessible shutoff required within 6 feet of an appliance and in the same room. $$ 5' - 5 " 5' - 0 " 5' - 0 " CL CL STORAGE (HEATED) 9'-0" 6' - 1 1 " $4 GFCI $ $4 D DI R E C T V E N T REMAINING LIGHTS PHOTOCELL ONLY HB $3 $3$3$$$3 $3GF C I GF C I HB $4 EV ch a r g e r INTERIOR WATER SHUT OFF: Provide pressure reducing valve and main water shut-off on water supply line. 500w CLST CLST CLST Install bollard or wheelstop to protect mechanical equipment from vehicle impact. . 2 of 2 Electric resistance wall heaters. D D GFCI 3-Way Switch USB Wet Outlet USB Outlet ELECTRICAL / MECHANICAL LEGEND Gimbal LED Modules 6'' LED Directional Recessed Fixture Dedicated Outlet Pendant $ Outlet P Switch with Dimmer$ $3 D Surface Mount Heat Alarm for garage SD Smoke Detector, interconnected Wall Mount exterior light CM Carbon Monoxide Detector Interior wall Sconce Switch Ceiling Fan Exhaust Fan & exhaust path Electric Wall Heater500w 220 Half Hot Outlet H ** Placement of outlets & lighting fixtures are for design purposes. Final placement shall be determined by 2020 NEC. Heat pump in the primary living area on the 2nd floor shall be installed in accordance with the manufacturer's instructions. Provide a programmable thermostat for the primary space conditioning system. Heaters shall be listed and labeled in accordance with UL 1042. Preliminary wattage listed on drawings based on .5 watts/square foot. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on building loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies. Kitchen - Use 100 CFM minimum fan Bath / Laundry - Use 50 CFM minimum fan All exhaust vents to be vented to the exterior with a 3' diameter clearance at termination from any operable openings. All habitable spaces shall be provided with operable windows with an openable area not less than 4 square inches of net free area cfm of outdoor air. All operable windows shall have screens and be controllable and securable. Smoke alarms to be placed inside all sleeping rooms, outside sleeping rooms and on all floors per IRC 314. Direct wiring is required. Carbon monoxide alarms required outside sleeping areas and on all floors per IRC315 Heat alarm required in garages with living space above. A minimum of 90% of all permanently installed light fixtures to be LED All recessed luminaires shall be Type IC-rated and labeled certified under ASTM E283 and shall have a label attached showing compliance with this test method. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering per R402.4.4 All outlets shall be placed per 2020 NEC. Place at 18" AFF, U.N.O. All interior main living area switches to include dimmers. Electronic dimmers on 3-way switches. All wet/damp area lights to be UL rated. See plan notes for placement of photocells and motion activated lights. All exterior lighting shall be shielded and directed away from residentially zoned lots and have a downward light beam. Place all GFCI and AFCI per 2020 NEC Code. ** The builder shall complete and post an Insulation Certificate for Residential Construction within 3 feet of the electrical panel prior to final inspection. ELECTRICAL / MECHANICAL / ENERGY NOTES LOCATION MIN CFMTYPE NOTES EXHAUST VENTILATION ONLY SCHEDULE 1. The minimal airflow rate for each exhaust must not be less than specified in Table 1505.4.4.(1) Range Hood Exhaust Fan Kitchen Bath 100 CFM 2. All vents must exhaust to the exterior of the building with a 3' clearance from operable openings per M1506.3. 50 CFM TYPE Intermittent Install per manufacturer instructions 3. Continuous whole house to be a maximum 1.0 Sone as required by M1507.3.4.2 Outlet - at 18" Ht Motion Sensing Under cabinet LED strip lighting Recessed LED downlight Vanity Lights Exhaust Fan Laundry 50 CFM Intermittent Install per manufacturer instructions HH 220v Outlet Exhaust Fan Linen Closet Continuous Operates as whole house fan Intermittent Install per manufacturer instructions 90 CFM Frost free hose bibHB Exhaust through ceiling 4. Local exhaust fans are permitted to serve as part of the whole-house ventilation system when provided with the proper controls per Section M1505.4.2. The system shall be designed and installed to exhaust and/or supply the minimum outdoor airflow rates per Section M1505.4.3 as modified by the whole-house ventilation system coefficients in Section M1504.5.3.1 where applicable. The whole-house ventilation system shall operate continuously at the minimum ventilation rate determined per Section M1505.4.2 unless configured with intermittent off controls per Section M1505.4.3.2. A5.1 DRAWN BY: vs DATE: 08.17.2022 SHEET TILE: Floor Plans PROJECT ADDRESS: 7606 206th St SW Unit C Edmonds, WA 98026 Edmonds Project No: OWNERS NAME: Rebecca West & Damian John PHASE: Permit Submittal Set Cycle REVISIONS: Edmonds APPROVAL STAMP 1 AD STUDIO LLC Val Sporleder Designer 206.604.1351 val@1ADstudio.com GENERAL CONTRACTOR: JoDaVue LLC 7606 206th St SW Edmonds,WA 98026 Sheet size: 24" x 36" SCALE: 1/4" = 1'-0"2 MEP - STUDIO SCALE: 1/4" = 1'-0"1 MEP - Garage and Storage THESE ARE SCHEMATIC DESIGN DRAWINGS: All electrical (low and line voltage) to be installed by licensed electrician per most recent electrical code. Final location of all switches, outlets and fixtures to be verified per homeowner post framing. Final placement of electrical meters and panel per code and approval of local code official and utility company sevicing the property. R403.3 INSULATION CERTIFICATE: Prescriptive path requirements for: Group R Occupancy, Climate Zone 4 (marine) ENERGY CREDITS SEC R406 Small dwelling unit (<1500) ...................................................................................3.0 Credits Needed Energy Credits Chosen: Table R406.2 Fuel Normalization: Heat Option 2: Ductless Heat Pump Primary heat source heat pump that meets federal standards for the equipment listed in Table C403.3.2(1)C or C403.3.2(2..........................................1.0 Credits Table R406.3 Energy Credits: Efficient Building Envelope - Option 1.1..............................................................0.5 Credits Prescriptive compliance is based on Table R402.1.1 w/the following modification: Vertical Fenestration U=0.24 Efficient Water Heating - Option 5.2.....................................................................0.5 Credits Energy Star rated gas water heater with minimum UEF of 0.80 High efficiency HVAC - Option 3.6 Ductless mini-split heat pump Min. HSPF OF 10.0..................................................2.0 Credits TOTAL 4.0 Steam Generator sized for final cubic feet of finished shower enclosure. Install per manufacturers written installation instructions including air space and maintenance requirements around unit. 240v required on dedicated circuit. WHOLE HOUSE FAN: A vent will be provided in wall above door. Label controls as "Whole House Ventilation". All 2nd floor exhaust fans will terminate at exterior above roof, TYP. @18" AFF ACCESS TO UNDER STAIRS. 18" X 24" MIN. Do not use MEP drawings for construction. Mechanical and plumbing placements are to be installed per latest, local mechanical and plumbing codes and fixtures should be installed per manufacturers installation instructions. Wiring continues to fixture and switching in lower lever. Under counter outlet for garbage disposal Under counter outlet for dishwasher See Electrical notes regarding air ceiling recessed fixtures. Dryer to vent directly to the outside with a maximum vent length of 25' and a maximum of two 90 degree elbows. Smoke detectors to be hard wired, interconnected and installed with battery backup. HEAT SIZING WORKSHEET:ENERGY CREDITS: EV Ready stall per to ECDC 17.115.040B Undercabinet LED strip lighting RECEIVED Sep 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT