Loading...
REVIEWED BLD2022-1276+Energy_Calculations+9.23.2022_9.18.55_AM+3125678Simple heating System Slze: wasnington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information JoDaVu Unit C 7606 206th St. SW Edmonds, WA 98026 Heating System Type: O All other systems Contact Information Val Sporleder val.sporleder@gmail.com 206-604-1351 0 Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) Edmonds AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 878 Average Ceiling Height Conditioned Volume Instruction< Average Ceiling Height (ft) 9.5 8,341 Glazing and Doors U-Factor X Area = UA Instructions u-o.za •J 0.240 203 48.60 Skylights U-Factor X Area = UA Instructions 0.50 --- Insulation Attic U-Factor X Area = UA Instructions � Select R-Value n 1 o selection Nli 0 --- Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions R 3s vented 0.027 660 17.82 Above Grade Walls (See Figure 1) U-Factor X Area UA Instructions R-21 Intermediate � 0.056 1,889 105.78 Floors U-Factor X Area UA Instructions 0.029 660 19.14 R-30 �� Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions No Below Grade Walls in this project. i� 0.028 0 Slab Below Grade (see Figure i) _ F-Factor X Length UA Instructions I 0.303 0 --- No Slab Below Grade in this project. Slab on Grade (see Figure 1) F-Factor X Length UA Instructions 0.360 106 37.98 R-10 Fully Insulated Location of Ducts Instructions 1 � Duct Leakage Coefficient No Ducts J 1.00 Figure 1. Above Grade Below Grade Sum of UA 229.32 W. CEIVED Sep 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-1276 Envelope Heat Load 10,549 Btu / Hour Sum of UA x AT Air Leakage Heat Load 4,144 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 14,693 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 14,693 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 18,366 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump (07/01/13)