APPROVED ENG BLD PLN RESUB2 BLD2022-1559+Architectural_Plan+3.16.2023_8.47.06_PM+34268722ZX_36 THESE DRAWINGS ARE THE SOLE PROPERTY OF KB PRO DESIGN LLG AND MAY NOT BE REPRODUCED IN ANY WAY WITHOUT THE EXPRESS WRITTEN CONSENT OF KB PRO DESIGN LLG VICINITY MAP I� 189TH PI SW 189th RI SW SITE i9oth St ss`.190TH ST SW 19015 80TH AVE W, � EDMONDS, WA 98026 Lu Q ACCESS ROAD Q tan Park � 1 J F 191ST ST SW I ; yi St SVL 192ND ST SW GENERAL NOTES 0 a CONVERS ON 19015 80TH AVE W, EDMONDS, WA 98026 1. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND COORDINATION WITH THE CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE CONTRACTOR. 2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. 3. DRAWINGS ARE NOT TO BE SCALED. CONTACT "KB PRO DESIGN" FOR RESOLUTION OF ANY CONFLICTS OR DISCREPANCY. 4. REPETITIVE FEATURES MAY BE DRAWN ONLY ONCE, BUT SHALL BE PROVIDED AS IF DRAWN FULL. 5. MECHANICAL AND ELECTRICAL FIXTURES, OUTLETS, ETC. WHEN SHOWN ON THIS DRAWINGS ARE FOR LOCATION INFORMATION ONLY. MECHANICAL AND ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS. 6. ALL DIMENSION LINES ARE TO FACE OF GWB. AND CENTERLINE OF COLUMNS AND BEAMS, UNLESS OTHERWISE NOTED. 7. IN THE EVENT OF FIELD ERRORS OR OMISSIONS, THE CONTRACTOR SHALL NOTIFY "KB PRO DESIGN" AND MAKE NO REPAIRS WITHOUT APPROVAL. 8. GENERAL CONTRACTOR RESPONSIBLE FOR ALL CUTTING AND PATCHING. 9. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES. 10. CONTRACTOR TO VERIFY ALL FIELD DIMENSIONS AND CONDITIONS - ANY DISCREPANCY BETWEEN PLAN AND ACTUAL CONDITION IS TO BE BROUGHT TO THE ATTENTION OF "KB PRO DESIGN" FOR RESOLUTION. 11. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS. ANY CHANGE TO SAME SHALL BE SUBMITTED TO "KB PRO DESIGN" IN WRITING FOR REVIEW AND APPROVAL. 12. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE CODE. PROVIDE FOR ALL REQUIRED SHOP DRAWINGS AND APPROVALS. 13. THE CONTRACTOR SHALL APPLY AND SECURE ALL OCCUPANCY, SEWER, STORM, WATER, ELECTRICAL AND OTHER PERMITS EXCEPT BUILDING PERMITS. CONTRACTOR SHALL PAY ALL NECESSARY FEES AND POST BONDS REQUIRED. 14. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE AS BEING NECESSARY FOR THE EXECUTION OF THE WORK. BY SUBMITTING A PROPOSAL, THE CONTRACTOR REPRESENTS THAT THROUGH EXAMINATION OF THE SITE AND ALL EXISTING CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT THE CONTRACT DOCUMENTS HAVE BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED BEYOND DOUBT THAT THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS ARE SUFFICIENT, ADEQUATE AND SATISFACTORY FOR CONSTRUCTION OF THE WORK. WHERE MINOR ADJUSTMENTS TO THE WORK ARE NECESSARY FOR THE PURPOSES OF FABRICATION AND INSTALLATION OF ITEMS, OR RESOLUTIONS OF CONFLICTS BETWEEN ITEMS, WITHIN THE INTENT OF THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO THE OWNER. WHERE SUCH MINOR ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN OF THE WORK, THEY SHALL BE SUBMITTED TO "KB PRO DESIGN" FOR REVIEW AND APPROVAL. 15. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO "KB PRO DESIGN" APPROVAL, AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL REQUIRED TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY "KB PRO DESIGN" AND OWNER PRIOR TO INSTALLATION. 16. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS, OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED. 17. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR STRUCTURAL COMPONENTS MUST BE APPROVED BY OWNER AND "KB PRO DESIGN". 18. ALL FLOORS SHOULD BE LEVEL AND NOT VARY MORE THAN 1 /4" IN 10"-0". THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY CONDITIONS THAT DO NOT MEET THIS STANDARD. 19. FLOOR FINISH TRANSITIONS SHALL OCCUR UNDER DOORS, UNLESS SHOWN OR NOTED OTHERWISE. 20. GLAZING IDENTIFICATION LABELS ARE TO REMAIN ON ALL GLAZING UNTIL THE INSULATION INSPECTION IS COMPLETE. 21. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE. 22. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS NOTED OTHERWISE. 23. INSPECTOR SHALL MAKE ANY FIELD MODIFICATIONS DEEMED NECESSARY IN ORDER TO MEET MINIMUM BUILDING CODE REQUIREMENTS. 24. ANY DEVIATION IN CONSTRUCTION FROM APPROVED PLANS REQUIRES PRIOR REVIEW AND APPROVAL FROM THE CITY. I � Vseparate Plumbing permit is required for this ■ .permit. Please obtain a Plumbing permit from Ithe City of Edmonds. ■ Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. ENGINEERING DIVISION APPROVED AS NOTED 11, 03/30/2023 APPROVED ALL WORK SUBJECT PLANS MUST BE TO FIELD ON JOB SITE INSPECTION FOR CODE COMPLIANCE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES APPROVED BY PLANNING Mar 17 2023 ABBREVIATIONS ADJ ADJUSTABLE / ADJACENT ALT ALTERNATE JAN JANITOR AFF ABOVE FINISH FLOOR JB JUNCTION BOX ALUM ALUMINUM J5T J015T L ANGLE JT JOINT KIT KITCHEN ANOD. ANODIZED LF LINEAL FOOT ACT ACOUSTICAL GEILING TILE LTG LIGHTING AT MAT'L MATERIAL MAX MAXIMUM BLDG. BUILDING MEGH MECHANICAL MED MEDIUM BLK'G. BLOGKING MEZZ MEZZANINE MFR BM BEAM MANUFACTURER 6/5 BUILDING STANDARD MISG MISCELLANEOUS MTD MOUNTED GAB CABINET MTL METAL GIRL CIRCULATION GLR CLEAR OR CLEARANCE N/A NOT APPLICABLE GL6 GEILING NIG NOT IN CONTRACT GL GENTERLINE NO NUMBER GOL COLUMN NOM NOMINAL GONG CONCRETE NT5 NOT TO SCALE GON5T GON5TRUGTION GONT CONTINUOUS OG ON CENTER GOORD COORDINATE OPN'6 OPENING GPT CARPET OPP OPPOSITE GT CERAMIC TILE PERP PERPENDICULAR DET DETAIL PL PLATE OR PLASTIC DIA DIAMETER LAMINATE DIM DIMENSION PLYHD PLYHOOD DN DOHN PNL PANEL DR DOOR PR PAIR DHG DRAHIN6 PROP PROPERTY PT PAINT EA EACH EL ELEVATION R RADIUS ELEG ELECTRIC RB RESILIENT BASE ELEV ELEVATION OR ELEVATOR RFGR REFRIGERATOR EN ENAMEL REINF REINFORCEMENT EQ EQUAL EX15T EXISTING REQ'D REQUIRED FF FACTORY FINISH REV REVERSE OR REV15ON FIN FINISH RM ROOM FLR FLOOR RO ROUGH OPENING FLUOR FLUORESCENT FOIL FURNISHED BY OWNER 5G SOLID GORE INSTALLED BY SECT SECTION CONTRACTOR 5HT SHEET SIM 51MILAR FT FOOT / FEET 5M SHEET METAL FTIG FURNISHED BY TENANT 50 SQUARE INSTALLED BY STD STANDARD CONTRACTOR 5USP SUSPENDED FURN FURNI5H / FURN15HINC75 GA GAUGE TELE TELEPHONE GALV GALVANIZED TEMP TEMPERED GL GLASS / GLAZING THERMO THERMOSTAT GHB GYPSUM HALL BOARD TYP TYPICAL HDH HARDHARE VAR VARIES HM HOLLOH METAL VGT VINYL COMPOSITION TILE HT HEIGHT VEN VENEER HVAG HEATING VENTILATING AIR VERT VERTICAL GONDITIONING VHG VINYL HALL GOVERIN6 IN INCH H WIDTH I NGAD INCANDESCENT H/ HITH I NGL INCLUDE H/O HI THOUT IN5UL INSULATION AG HALL GOVERING I N5TL INSTALLATION HD HOOD City Of Edmonds Building Department Work GARAGE CONVERSION Address 19015 80TH AVE W Owner SULLY Approved Date 3/24/2023 Building Official ofAaIc Permit Number LBLD2022-1559 REV1 REV2 REVISIONS Building Department REV3 REV4 REV5 PROJECT DESCRIPTION THE 5GOPE OF WORK OF THIS PROJECT HAS TO CONVERT THE EXISTING GARAGE AND STORAGE AREA INTO A LIVABLE AREA. NEW PLAN LAYOUT AS PER A/A2.0 THAT INGLUDE5 3 BEDROOMS, FULL BATH AND LAUNDRY. EXI5TIN6 5HOHER IN THE EXISTING BATHROOM 15 TO BE REMOVED AND REPLACED WITH A NEW 5HOHER/TUB COMBO. NO GHANOE TO THE STRUCTURE OF THE HOUSE IS BEING DONE PER THIS SCOPE OF WORK. NO SITE HORK IS BEING PERFORMED PER THIS PERMIT. CONSTRUCTION & CODE NOTES ENERGY PRE5GRIPTIVE PATH REQUIREMENTS FOR GROUP R OGGUPANGY AND CLIMATE ZONE 5 4 MARINE 4, PER TABLE R402.1.1, 2018 HA5HINGTON STATE ENERGY GODE INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT FENESTRATION U- 0.50 GEILING R-4q HOOD FRAME HALL R-21 (IN 2X(b HALL MIN) FLOOR R-30 BASEMENT HALL R-10 / R-I5 / R-21 + 5TB ENERGY CREDITS (PER TABLE R406.3, 2018 HA5HINOTON STATE ENERGY CODE) REQUIRED CREDITS 3 CREDITS #*I*EWW** 3.1 HIGH EFFICIENCY LENNOX ML296UH070XV36B-55 6A5 FURNACE, HVAG EQUIPMENT I CREDIT 2-5TAGE, qb% EFFICIENT, UPFLOH, 3-TON WITH OPTIONS 70,000 BTU's CONTROL AND 1.5 CREDITS EFFICIENT VENTILATION APPLIANCES TO BE SELECTED BY OWNER OR CONTRACTOR AND TO PROVIDE DOCUMENTATION 7.1 APPLIANCE 0.5 CREDITS OF Energy Star Compliance TO THE IN5PEGTOR PAGKAGE AT THE FIELD IN5PEGTION. AT THE TIME OF IN5PEGTION, ALL APPLIANCES SHALL BE INSTALLED AND CONNECTED TO UTILITIES. VENT / FANS / ALARMS VENT FANS • - KITCHEN FAN MIN. 100 GFM - BATH AND LAUNDRY FANS MIN 50 GFM. THE FANS SHALL VENT DIRECTLY TO THE EXTERIOR OF THE BUILDING. EXHAUST TERMINATION TO EXIT THE STRUCTURE NOT LE55 THAN 3 FEET FROM PROPERTY LINE, 3 FEET FROM OPERABLE OPENINGS INTO THE BUILDING AND 10 FEET FROM MECHANICAL AIR INTAKE. • INSULATE ALL DUCTS OUTSIDE OF CONDITIONED 5PAGE PER HA. STATE ENERGY CODE. CARBON MONOXIDE ALARMS PER 200 IRG R315 • REQUIRED LOCATIONS PER IRG R315.3: • EXISTING DHELLIN65 PER IRG R315.2.2 • COMBINATION ALARMS PER IRG R315.4 • POHER 5OURGE PER IRG R315.6 • INTERGONNECTIVITY PER R315.5 SMOKE ALARMS PER 2018 IRG R314 AND NFPA72: • REQUIRED LOCATION PER R314.3 • INTERCONNECTION PER R314.4 • COMBINATION ALARMS PER R314.5. • POWER SOURCE PER R314.6 . NOTES: • PER IRG R30&.4, SAFETY GLASS TO BE PROVIDED IN HAZARDOUS LOGATION5. • REPLACED WINDOWS IN LOCATIONS THAT REQUIRE EMERGENCY EGRESS OPENINGS ARE PERMITTED TO HAVE SILLS HIGHER THEN 44". THE REPLACEMENT WINDOW MUST BE THE LARGEST STANDARD 51ZE WINDOW TO FIT HITHIN THE EXISTING OPENING, OR PROVIDE EQUAL OR GREATER OPENING AREA AS THE EXISTING HINDOH (IRG R310.2.5). DRAWING INDEX SHEET DESCRIPTION REV. NO. AO.O COVER SHEET I, AI.O 51TE PLAN I, A2.0 EXISTING, DEMO AND NEW PLAN I, A2.1 REFLECTED GEILING PLAN I, 2, LEGAL DESCRIPTION FRED A FISHER ACRE TR5 BLK 000 0-05 - ELY b&FT OF HLY 324FT OF LOTS 3 $ 4 CODES 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 HA5HINGTON STATE ENERGY CODE 2018 UNIFORM PLUMBING GODE 2018 IGG PERFORMANGE CODE CITY OF EDMONDS ZONING PROJECT STATISTICS PARCEL NUMBER 00451200000505 ADDRESS 19015 BOth Ave H, Edmonds, HA g8026 ZONING R5-8 PRnPERTY TYPE R MINIMUM REQUIRED SETBACK STREET 5ETBAGK 25' SIDE SETBACK 7.5' REAR SETBACK 15' MINIMUM LOT GOVERAGE 35% MINIMUM PARKING SPACES 2 EXISTING AREAS LOT 51ZE 8,275 S.F. / O.Icl AG EXISTING HOUSE FOnTPRINT 1,040 5.F. EXISTING GONGRETE PATIO 400 5.F. EXISTING SHED 50 S.F. TOTAL LIVING 1,586 S.F. (FINISHED) LIVING AREA: I5T FLOOR ---------------------- I, 06b 5.F. ( FINISHED ) BASEMENT --------------------- 520 5.F. ( FINISHED ) BASEMENT --------------------- 520 S.F. ( UN -FINISHED GARAGE ) CONVERTED EXISTING AREAS 520 5.F. ( NEW FINISHED AREA/ BASEMENT --------------------- CONVERTED GARAGE INTO LIVING AREA) NO ADDITION TO THE EXI5TIN6 5TRUGTURE TOTAL LIVING AREA AFTER 2,106 S.F. HEATED FINISHED AREA REMODELING LOT COVERAGE CALCULATIONS LOT 51ZE 8,275 S.F. DRIVEHAY EA5MENT 1,462 S.F. TOTAL EXISTING AREAS 1,4g0 S.F. LOT GOVEI�AGE 21.9% EXISTING (MEGHANIGAL GONTRAGTOR TO VERIFY EXI5TING UNIT AND ITS COMPLIANCE HITH CURRENT CODES) " ANY REQUIRED CALCULATIONS TO BE HEATING SYSTEM PROVIDED BY THE CONTRACTOR " EXISTING DUGTING FROM (E) FURNACE HILL BE USED A5 HEAT SOURCE FOR THE NEW AREAS. CALCULATIONS BY HVAG CONTRACTOR . VENTILATION 5Y5TEM EXISTING IF NOT EXISTING CONTINUOUS WHOLE HOUSE ( NEW BATH ROOM VENT HILL BE SET UP VENTILATION A5 WHOLE HOUSE VENTILATION) HOT HATER EXISTING PROJECT CONTACTS OWNER COLIN SULLY Ig015 BOth Ave H EDMONDS, HA g8026 P: (425) 583-5&07 EMAIL: colin.5ully@yahoo.com DE516N KB PRO DESIGN PROFESSIONAL Gontact : Owen K. 400 NH Gilman Blvd #171, ISSAQUAH, HA 18021 P: (425) 414-4264 E: office®KbProDesign.com GONTRAGTOR Green Built NH Gontact : Fabian Quirogo 18604 76th Ave H, EDMONDS, HA 98026 R E S U B P: (206) 274-1226 E: fobian®greenbuiltnw.com 3/16/2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT THESE DRAWINGS ARE THE SOLE PROPERTY OF KB PRO DESIGN LLG AND MAY NOT BE REPRODUCED IN ANY WAY WITHOUT THE EXPRESS WRITTEN CONSENT OF KB PRO DESIGN LLG PERMIT 24X36 THESE DRAWINGS ARE THE SOLE PROPERTY OF KB PRO DESIGN LLG AND MAY NOT BE REPRODUCED IN ANY WAY WITHOUT THE EXPRESS WRITTEN CONSENT OF KB PRO DESIGN LLG ADJACENT EXISTING RESIDENCE I x x I x x I L---------- I x x Q x x p LU r 5 I PROPERTY LINE X X X X X X X X X C X X X X I U) 1-011 z (E) WOOD FENCE (n VERIFYINPLACE w I w >4 FQ 10, 5� 25' U LU Q O U j EXI5TINa z PRIMARY ENTRANCE 21 w EXISTING RESIDENCE X — —1O' — 19015 80TH AVE W IJF I W DRIVEWAY EASEMEN xl O EXISTING GARAGE Q CONVERTED INTO LIVING a -AREA z e U- I o w AREA OF WORK THIS o I LU _ oz z_ cn PERMIT 0 AREA w w 26' _ I LU O I I15'-0" REAR 5ETBAGK � 1 PA IN AREA J 0 I I VERIFY IN PLACE 25'-0" STREET 5ETBAGK , o z - EXISTING CONCRETE PAVED AREA - -- -- --- - - - -. - LU > (E) SHED (E) WOOD FENCE 122' 00" v- � rm %C ADJACENT EXISTING x N--� RESIDENCE I o I N I k x I ADJACENT EXISTING RESIDENCE RESUB 3/16/2023 NEW SITE PLAN o 4 8 16 CITY`OOED A SCALE. 1/8 = 1-0 P SERVICE DE R T THESE DRAWINGS ARE THE SOLE PROPERTY OF KB PRO DESIGN LLG AND MAY NOT BE REPRODUCED IN ANY WAY WITHOUT THE EXPRESS WRITTEN CONSENT OF KB PRO DESIGN LLG PERMIT ZX,336 THESE DRAWINGS ARE THE SOLE PROPERTY OF KB PRO DESIGN LLG AND MAY NOT BE REPRODUCED IN ANY WAY WITHOUT THE EXPRESS WRITTEN CONSENT OF KB PRO DESIGN LLG PLAN LEGEND / NOTES DEMO PLAN NOTES z0 WATERPROOF MEMBRANE EXTERIOR FINISHING THE SAME LIKE EXISTING (E) DOOR 1 NEW DOOR O rFl h®x HL— lW wv x H _ZANEW NORTH DIRECTION � � I I Q N 1/2" EXTERIOR (E) - DOOR SIZE - DOOR SIZE ���'� REMOVE DASHED DOORS, WALLS, z z _ - 5HEATIN6 -WINDOW SIZE " NEW -WINDOW SIZE " WALL TYPE ---- — I --- _ _ _ _ CEILING TILE $ GRID, FIXTURES, Tl'P. - z O� — p� - ��(E) r l W x HT (NJ wv x� �% (SEE DET I /A2.0) w (E) WINDOW NEW WINDOW 1. REFER TO ELECTRICAL AND MECHANICAL DRAWINC75 FOR DEMOLITION 1/2" GWB REQUIREMENTS RELATED TO ELECT. AND MECH. SCOPE OF WORK. v I/ 0 (E) EXTERIOR FRAMED 2. ALL EXISTING DOORS, RELITE5, FRAMES, AND HARDWARE DE516NATED TO -N WALL w/ (E) R-21 DETAIL BE REMOVED, SHALL BE SALVAGED FOR RE-U5E TO THE MAXIMUM EXTENT POSSIBLE AND PRACTICAL. = _ \ % z BATT INSULATION : NEW R-5 GI TO BE X DETAILS ADDED TO THE WALL AX.Y SHEET 3. SALVAGE AND REUSE, TO THE MAXIMUM EXTENT PRACTICAL, ELECTRICAL NUMBER DEVICES SUCH AS OUTLETS, 5WITGHED, BOXES, A.V. CONTROLS, SENSORS, _ 0 (E) INTERIOR WALL THERMOSTATS, ETC. z = NEW INTERIOR WALL ----`1 4. EXISTING SURFACES AND FINISHES SHALL BE PATCHED, REPAIRED, AND Q 1/2" GWB 0 FINISHED TO MATCH EXISTING SURROUNDING SURFACES. REPLACEMENT AND 2x4 WOOD p 1/2" GWB R-21 GATT PER WALL TYPE A1X.2 ' ENLARGED PLANS / DETAILS ' REPAIR FIN15H MATIERIAL5 SHALL MATCH EXISTING WHERE EVER PRATIGAL. p STUDS @ 24" O.G. z INSULATION 0 NEW EXTERIOR FRAME ____ < p- 2x6 WOOD Y_ STUDS @ 24" O.G. R-5 GI WALL PER WALL TYPE FULL HEIGHT TO FLOOR/ f� INSULATION REV1510N5 �J B 5TRUGTURE ABOVE FULL HEIGHT TO FLOOR/ (EJ EXISTING NOTE: /`1 STRUCTURE ABOVE < > • FINISHES TO BE FIELD COORDINATED BETWEEN OWNER (D� DEMO AND CONTRACTOR PRIOR TO CONSTRUCTION. • WET AREAS TO RECEIVE 6REENBOARD DRYWALL. (N) NEW WALL TYPES SCALE. 3 = 1-0 PLAN KEYNOTES OREMOVE EXISTING GARAGE DOOR EXISTING WALL FOR NEW WINDOW. SEE NEW PLAN FOR OREMOVE DIMENSIONS. 1 ST_FLOOR: (NO WORK PER THIS PERMIT) OREMOVE EXISTING WASHER FLOOR HEATED AREA: 1,066 S.F. ®1ST REMOVE EXISTING SINK BASEMENT LEVEL OREMOVE EXISTING DRYER BASEMENT HEATED AREA: 1040 S.F. 8 A2.1 © REMOVE EXISTING SHOWER 2 TOTALS OREMOVE EXISTING WALL �X TOTAL HOUSE HEATED AREA: 2,106 S.F. (rU 5'-O"x4'-O" OPj EXISTING METAL COLUMN TO REMAIN I :�1_01 1 2'-01 T EGRE55 OEXISTING TANKLE55 WATER HEATER TO REMAIN I I 14'-4" W lO'-5" O Q AG� EXIST BEDROOM #1 @EXISTING SINK TO REMAIN v � p NEW � o I r o ioi s.F. EXISTING TOILET TO REMAIN 1 II tv � \ ? _ EXIST k - x "' BEDROOM #2 II?S.F. �� z I z z _ L(� k ° �2 O EXISTING OUTDOOR AREA I I 11 it U > BEDROOM #1 O t `��' Q 3'-3" I'-6" �3 EXISTING FIRE PLACE TO REMAIN g II EXIST 8 ` ENERGY CREDITS: A2.1 C'S w /4'-3 " B r lO'-5" , 4'_bi�2�� �4 EXISTING FURNACE S NEW WASH AND DRYER Q II GARAGE/STORAGE (Ei REDIT 1.4 THE REQUIREMENTS ARE: , I �E)11 NEW TUB/SHOWER COMBO g I I �� q _ , F'RES�,R1�� GOHP'_iAP'.;.t 15 b",SED 0P: I#E t-2.i.l NEW cam' ALIGN LAUNDRY q NEW TOILET i I v WITH THE FtfWNC MODIFICATIONS: • VERTIGALTEt&TRATION U � u 1 < �'�'i NEW 10 21 S.F. ry - O 18 NEW 60" VANITY ; o NEW B B B ;; _ 4 • WALL R-21 PLUraY GI •FLOOR R-38 x _ BEDROOM #3 �t Ei HALL 48 S.F. dJ 15 �{ NEW TUB/SHOWER COMBO II ? O \ �' • BASEMENT WA I R-5 GI •SLAB ON R-10 PERI AND UNDER 11 113 S.F. z — U- ° G.L. OF NEW WALL ALIGN w/ G.L. OF EXISTING METAL COLUMN 3 ST 5 ITY EN TIR • BE GRADE SLAB R-10 PERIMETER UNDER �T E SLAB OR COMPLIANCE BASED O ION R402.1.4: REDUCE THE TOTAL CONDUCTIVE U B > ,-- tiJ �6+ O 17 0' � 18 Lu 0 N w m z o 21 I6 _ 2I NEW BUILT-IN SHELVES NEW WINDOW5. SILL HEIGHT, TYPE AND 51ZE TO MATCH EXISTING WINDOWS JEXI __—, -- 15%. 6� c Q 00 �O FROM UPPER FLOOR. NEW AND EXISTING WINDOWS TO BE LINED UP. 0 II 0 o I FOR CREDIT 3.1 THE REQUIREMENTS ARE: 2-6 x6 8 1 p U P ®® • ENERGY STAR RATED (U.S. NORTH) GAS OR PROPANE U P W I ®� q \' FURNACE w/ MIN. A.F.U.E. OF a5% q x OR ' Z 0 k �0 -"EXIST �0 14 \ �� ' • ENERGY STAR RATED (U.S. NORTH) GAS OR PROPANE --- l c4 14 ® e m MAIN ENTRY .kp d ____� in 10 ry FURNACE w/ MIN. A.F.U.E. OF a0% et�j EXIST MAIN ENTRY <r o O .Q EXIST N LANDING U P_ II 12 • TO QUALIFY TO CLAIM THIS CREDIT THE BUILDING LANDING U �= N ® 10 BATHROOM#1 12 N -- EXIST PERMIT DRAWINGS SHALL SPECIFY THE OPTION lq � sF BAH><JHEATING BEING SELECTED AND SHALL SPECIFY Y=THE "�<b EQUIPMENT TYPE AND THE MIN. EQUIPMENT B ; (E)NOTE: 2-4-8 EF IG NG //'-6" I 2'-lO" 1 2'-4'xb'-8" • ALL FINISHES TO BE FIELD COORDINATED BETWEEN OWNER AND FOR CREDIT 2.3 THE REQUIREMENTS ARE: 2 I ALIGN CONTRACTOR PRIOR TO CONSTRUCTION. I I COMPLIANCE BASED ON SECTION R402.4.1.2: N I I I I • REDUCE THE TESTED AIR LEAKAGE TO 1.5 AIR I I x GHAN6E5 PER HOUR MAXIMUM AT 50 PASCALS EXIST LIVING ROOM • ALL WHOLE -HOUSE VENTILATION REQUIREMENTS AS EXIST I �i I O DETERMINED BY SECTION M150-7.3 OF THE IRG OR �n ; LIVING ROOM iv ' iU Ul SECTION 403.8 OF THE IMG SHALL BE MET WITH A cv HEAT RECOVERY VENTILATION SYSTEM WITH MINIMUM k SENSIBLE HEAT RECOVERY EFFICIENCY OF 035. x I I • TO QUALIFY TO CLAIM TH15 CREDIT, THE BUILDING PERMIT DRAWINGS SHALL SPECIFY THE OPTION 25 -/U2 BE16N SELECTED AND SHALL SPECIFY THE MAXIMUM 25 /�2 I I TESTED BUILDING AIR LEAKAGE AND SHALL SHOW I I 13 I I THE HEAT RECOVERY VENTILATION SYSTEM. 13 ' ' FOR CREDIT -7.1 THE REQUIREMENTS ARE: ' 0 3' 8"x2'-4" ALL OF THE FOLLOWIN6 APPLIANCE SHALL BE NEW AND ( 3' 6'x2'-4" INSTALLED IN THE DWELLING UNIT AND SHALL MEET THE FOLLOWING STANDARDS: • DISHWASHER - ENERGY STAR RATED • REFRIGERATOR (IF PROVIDED) - ENERGY STAR RATED • WASHING MACHINE - ENERGY STAR RATED • DRYER - ENERGY STAR RATED, VENTLESS DRYER WITH A MINIMUM GEF RATING OF 5.2 • TO QUALIFY TO CLAIM THIS CREDIT, THE BUILDING PERMIT DRAWINGS SHALL SPECIFY THE OPTION BEIGN SELECTED AND SHALL SHOW THE APPLIANCE Tl PE AND NRCUvIDE DOGI)HEN: I ATION Or ENERGY' STAR COMPLIANCE. AT THE TIME OF INSPECTION, ALL APPLIANCE SHALL BE INSTALLED AND CONNECTED TO UTILITIES. DRYER DUCTS AND EXTERIOR DRYER VENT GAPS ARE NOT PERMITTED TO BE INSTALLED IN RESU B THE DWELLING UNIT. 3/16/2023 EXISTING AND DEMO PLAN 0 2 4 8 12 NEW PLAN 0 2 4 8 CITY d9ED B A O SCALE: 1 /4" = 1'-0" SCALE: 1 /4" = 1'-0" SERVICE DE ME T THESE DRAWINGS ARE THE SOLE PROPERTY OF KB PRO DESIGN LLG AND MAY NOT BE REPRODUCED IN ANY WAY WITHOUT THE EXPRESS WRITTEN CONSENT OF KB PRO DESIGN LLG PERMIT 24X36 THESE DRAWINGS ARE THE SOLE PROPERTY OF KB FRO DESIGN LLC, AND MAY NOT BE REPRODUCED IN ANY NA"r WITHOUT THE EXPRESS WRITTEN CONSENT OF <E3 PRO DESIGN LLC PLAN LEGEND NOTES EXISTIN6 6EILIN6 (2) 2x NAILER Z NEOPRENE 5A5KET NEW CEILIN6 6HB 2x NAILER ROOF JACK G SMOKE PETEGTOR 1OP CARBON MONOXIDE DETECTOR \--INTERIOR 2x STUDS INTERIOR 2x STUDS 0 L I 67HT PER PLAN PER PLAN ROOFING LAPS FLASHIN EXHAUST FANS \-2x STUDS \-2x STUDS AT SIDES AND TOP PER PLAN PER PLAN 0_1 EXHAUST FANS AND LI 6HT COMBO TO BE SET UP AS A WHOLE HOUSE FAN - RUNNING CONTINUOUSLY AT 75 CFM AND MAX 1.0 50NE FLASHING LAPS ROOFING AT BOTTOM 6EILIN6 REGISTER (TO BE CONNEGTED TO THE EX15TIN6 DUCTING FROM THE EX15TIN6 FURNACE, HVAC, CONTRACTOR TO 00 VERIFY EX15TIN6 FURNACE AND ITS COMPLIANCE WITH CURRENT CODES, ANY REQUIRED PERMITS TO BE PROVIDED BY GONTRA6TOR UNDER SEPARATE PERMIT. 82 STANDARD OUTLET #GFI-2 OF I OUTLET PEPENDICULAR WALL CONNEC ROOF JACKS AND VENTS POVER 5HITCH SCALE: 6EILIN6—/ EMER6ENC,Y E56APE AND RESCUE OPENINC75 INTERIOR 2x STUDS SHALL BE INSTALLED IN BASEMENTS, HABITABLE ATTICS, AND IN 5LEEPIN6 ROOMS; PER PLAN OPENABLE W/O U5E OF KEYS, TOOLS, OR SPECIAL KNOWLEDGE. IR6 R310! * MIN. 53 5F NET UR OPENABLE AREA * MIN. 24" NET GLR OPENABLE HEIGHT * MIN. 20" NET GLf;Z OPENABLE WIDTH * MAX. 44" FINISHED 5ILL HEIGHT 6H15 EA. SIDE 2x NAILER -Av-- - O z. C) . . . . . . . . . . . 7 z 2 FINISHED FLOOR x < CORNER WALL CON NEC WINDOW CONTROL HT. 1 1 1 1 1 1 1'� I 1 1 I I I I I I I I I I I I I I � I I I I 1 19, 1 1 1 1 qS11 I 12 1 1 1 1 1 1 III I I I I I I I I I I I I I I SCALE: 1 V-0" 2 &YS-C-ALE: 1/2" V-0" #745. 15# FELT FLASHING I I I I I I I I I I I I I I 1 711 1 I 1 1 1 I'l,I I I I I I 1 11 1 BUTT BEHIND 510INC JOINTS KAI L I" FROM TOP AND NO GLO5ER THAN"1111111111111111111111111111121 FROM EDGE OF BOARD I I I 1 01 1 1 1 1 1 1 1 1 1 1 1 11 1 1 11 1 __v HOUSE WRAP t'l �I I l­ y I Range, for I I I I I- _L I I I I I I 1 4� I I I 1 1 11 1 1 111 r rcl 7__ Thormo5tote,,Outlote, I I I I I I I I I I I I I I I I 1 1011 11 1 1 1 1) 1 11 1 1 1 ,I� I I I I it and Electrical 11 11111 All I PcInele, t Lu D Ly < NOTE: Lu 00 NOT ATTEMPT TO FLASH WITH HOUSE WRAP AS IT WILL NOT DIRECT HATER AWAY FROM THE HALL. 0 c� SIDINGSHOULD BE FASTENED TO FRAMING. IF NO STUD 15 x < AVAILABLE, PLACE ON NAIL I" BELOW TOP OF BOARD AND I" FROM THE BUTT E06E. PLACE ANOTHER NAIL 3" FROM THE BUTT E06E. IT 15 NEVER AGGEPTABLE TO LEAVE A GAP OF ANY SIZE AT A BUTT END/JOINT. BUTT JOINTS ELECT. REACH RANGE (DSIDING SCALE: 1 1'-0" )/2" IV2 3 SCALE: 1/2" = 1'-10" 7— A v BOTTOM OF (E) FLOOR JOISTS EX15TIN6 FLOOR PLAN 5Y2" J",,// PLAN DIMENSION DIMENSION NOTE PT LUMBER RIPPED TO x < :K FRAM INO EXTERIOR FINISHING 2xb HOOD STUDS @ 24" 0. MATGH SLOPE OF SLAB, MIN DEPTH OF 1�". TREAT GUT cHB THE SAME LIKE EX15TIN C7 ­�---R-21 BAIT INSULATION 51DE WITH HOOD I PRESERVATIVE. 7= WATERPROOF MEMBRANE R-5 GI INSULATION VAPOR BARRIER - LAP z Lu z z EXISTINO 67ARAOE DOOR HEADER 1/2" EXTERIOR 5HEATIN 1/2" 6HB 5PLIGE5 12" MIN AND RUN 6" Q_ T � IS) Qn 2 MIN UP THE 51DE5 U- G_/ 7x = U- Lu HALL PER Z T px w -_ PLAN R-10 BAIT INSULATION c� _j Lu y (2)2xib HEADER A EL- :K < 0� 0 x- <7 :K Lu z < z 0 F:: Lu (3 SAME LEVEL WITH EXISTING WINDOW PLYWOOD —BOTTOM OF 5TRUGTURE 0 •2x2 PT LUMBER @ 24" O.G. MAX u') • R-15 RIC710 INSULAT11 N NEW WINDOW 7 Lu• < •6 MIL VAPOR BARRIER (E) GONGRETE SLAB L PER PLAN (E) FIN15H FLOOR I RESUB [x] A '4 3/16/2023 HEADER SECTION WALL SECTION REFLECTED CEILING PLAN 0 8 9l ED 2 4 CITY d A SCALE: 1/4" = 1'-131" Lop SERVICE E +T SCALE: 1-1/2" = 1'-10" SCALE: 1/2" = 1'-10" O O O CL THESE URANINGS /-\RE THE SOLE PROPER] Y OF KB FRO -7E7�'E�[77j= EXPRESS WRITTEN CONSENT OF KB PRO DESIGN LLG PERMIT