Loading...
REVIEWED RESUB2 BLD2022-1559+WSEC+3.16.2023_8.47.06_PM+3426871REVIEWED g�p2022.1559 BY Simple Heatina System Size: Washington State CITY OF EDMONDS T E Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information Permit Application Number: 6901482 - CN Owen K. with KB Pro Design 19015 80TH AVE W 425 414 4264 EDMONDS, WA 98026 A owen@kbprodesign.com Heating System Type: OO All other systems O Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions". R E S U B Design Temperature Edmonds Design Temperature Difference (AT) 46 AT = Indoor (70 degrees) - Outdoor Design Temp 3/16/2023 Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sci ft) 2,132 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 7.71 16,416 Glazing and Doors U-Factor X Area = UA Instructions U-0.30 I0.300 252 75.68 Skylights U-Factor X Area = UA Instructions 0.50 --- Insulation Attic U-Factor X Area = UA .—tructions L R-38Advanced I 0.026 JI 1,066 27.72 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions 6 No Vaulted Ceilings in this project. J --- Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions r R-21 Intermediate 0.056 1,861 104.19 Floors U-Factor X Area UA Instructions L No Floors above unconditioned spaces. � J --- Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-21 interior I 0.042 J 138 5.80 Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions61 R-5 Thermal Break at slab edge � 0.570 1,040 592.80 Slab on Grade (see Figure 1) F-Factor X Length UA Instructions Select R-Value � I No selection 0 --- Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space 1.00 Sum of UA 806.18 Figure 1. Above Grade CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Envelope Heat Load 37,084 Btu / Hour Sum of UA X AT Air Leakage Heat Load 8,156 Btu/Hour VolumeX 0.6XATX.018 Building Design Heat Load 45,240 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 45,240 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 63,336 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113)