APPROVED BLD2023-0058+Plumbing_Plan+1.15.2023_6.26.52_PM+33155957
00
I-�
O
N
r
C'7
N
O
N
\
�SCXSNIC)
®
PLUMBING FIXTURE
---
COLD WATER PIPE (CW)
----
HOT WATER PIPE (HW)
-----
HOT WATER RECIRC PIPE (WWC)
—GAN—
SANITARY PIPE (SAN)
-------
VENT PIPE (V)
—S—
STORM PIPE (S)
Oft
RAIN LEADER (RL)
0 RD
ROOF DRAIN (RD)
OO GD
OVERFLOW DRAIN (OD)
—G —
GAS PIPE (G)
—STM —
STEAM PIPE (STM)
—COND—
CONDENSATE RTN. PIPE (COND)
is
HOSE BIBB/WALL HYDRANT
--iij>-
BALL VALVE
--t>4-
GATE VALE
—10,411
GATE VALVE w/GAP
—CP4—
BALANCING VALVE
�—
GAS COCK/VALVE
GLOBE VALVE
--DO*—
ANGLE GLOBE VALVE
3-WAY MOTORIZED VALVE
CONTROL VALVE
CHECK VALVE
PRESSURE RELIEF VALVE
PRESSURE REDUCING VALVE
PRESSURE REDUCING STATION
BACKFLOW PRE V. STATION
—II
PIPE CAP OR SANITARY CLEANOUT
PIPE BREAK
�c
PIPE UP
PIPE DOWN
PIPE TEE UP
PIPE TEE DOWN
PIPE FLANGE
—III—
UNION
FLEX CONNECTION (PIPE)
STRAINER
AIR VENT
PRESSURE GUAGE
THERMOMETER
eHVACEQUIPMENT
NUMBER/
PLUMBING FIXTURE DESIGNATION
24/12
RECTANGULAR DUCT SIZE
I2"*
ROUND/SPIRAL DUCT SIZE
24/12#
OVAL DUCT SIZE
CEILING DIFFUSER - SQUARE
0
CEILING DIFFUSER - ROUND
mgmm
L INEAR/SLOT DIFFUSER
®-+
RETURN AIR/EXHAUST GRILLE
WEATHER LOUVER/WALL GRILLE
SUPPLY AIR ARROW
E1r
RETURN AIR/EXHAUST ARROW
THERMOSTAT/SENSOR
$
SPIN -IN w/VOLUME DAMPER
IIIIIIIIII
FLEX DUCT (0)
DUCT, RECT (*) / ROUND (*)
W
SOUNDL INED DUCT/DUCTBORD
®
SUPPLY AIR DUCT DOWN
®
SUPPLY AIR DUCT UP
®
RET/EXH DUCT DOWN (*)
m
RET/EXH DUCT UP (*)
®
ROUND/SPIRAL DUCT DOWN (0)
®
ROUND/SPIRAL DUCT UP (*)
RECT DUCT BREAK
C
ROUND/SPIRAL DUCT BREAK
RECT ELBOW w/TURN VANES
RADIUS ELBOW C* / m)
3:c
TRANSITION
SQUARE -ROUND TRANSITION
FLEX CONNECTOR * EQPT.
FIRE DAMPER
+-}®
SMOKE DAMPER
+ij
VOLUME DAMPER (VD)
++@
VOL. DMPR. w/REMOTE OPER.
4ft.~40
MOTORIZED DAMPER
—MM —
HYDRONIC WATER SUPPLY
—WM—
HYDRONIC WATER RETURN
—016 —
CONDENSER WATER SUPPLY
—CM—
CONDENSER WATER RETURN
—CHB—
CHILLED WATER SUPPLY
—CHR—
I CHILLED WATER RETURN
AAV
AUTOMATIC AIR VENT
AC
AIR COMPRESSOR,
AIR CONDITIONING
AD
AIR DRYER
ADA
AMERICANS WITH
DISABILITIES ACT
AFF
ABOVE FINISHED FLOOR
AHU
AIR HANDLING UNIT
AL
ALUMINUM
ALT
ALTERNATOR, ALTERNATIVE
APD
AIR PRESSURE DROP
ARC
AIR RECEIVER
ASHRAE
AMERICAN SOCIETY OF
HEATING REFRIGERATION
AND AIR CONDITIONING
ENGINEERS, INC
ASME
AMERICAN SOCIETY OF
MECHANICAL ENGINEERS
B
BOILER
BC
BRANCH CONTROL
BDD
BACKDRAFT DAMPER
BFF
BELOW FINISHED FLOOR
BOD
BOTTOM OF DUCT
BTUH
BRITISH THERMAL UNITS
PER HOUR
BY
BALANCING VALVE
CA
COMPRESSED AIR
CC
COOLING COIL
CD
CONDENSATE DRAIN
CFH
CUBIC FEET PER HOUR
CFM
CUBIC FEET PER MINUTE
CLG
CEILING
CN
CONDENSATE NUMBER
CO
CLEANOUT
CONT
CONTINUATION
COP
COEFFICIENT OF PERFORMANCE
CP
CIRCULATION PUMP
CU CONDENSING UNIT
MECHANICAL 1455RIV I AT IONS
DSN
DOWN SPOUT NOZZLE
HWR
HEATING WATER RETURN
RL
RAIN LEADER
DWV
DRAIN, WASTE AND VENT
HWS
HEATING WATER SUPPLY
RPBFP
REDUCED PRESSURE
BACKFLOW PREVENTOR
DX
DIRECT EXPANSION
HX
HEAT EXCHANGER
RPM
REVOLUTIONS PER MINUTE.
EA
EACH OR EXHAUST AIR
HZ
HERTZ
5
SINK
EDB
ENTERING DRY BULB TEMPERATURE
ID
INSIDE DIAMETER OR DIMENSION
SA
SUPPLY AIR
EER
ENERGY EFFICIENCY RATIO
IE
INVERT ELEVATION
SAD
SUPPLY AIR DAMPER
EF
EXHAUST FAN
IN
INCH
SD
SUPPLY DIFFUSER
EFF
EFFICIENCY
KW
KILOWATT
SF
SUPPLY FAN OR SQUARE FT
EG
EXHAUST GRILLE
L
LAVATORY
SG
SUPPLY GRILLE
ERV
ENERGY RECOVERY VENTILATOR
L-X
LOUVER
SHR
SHOWER
ESP
EXTERNAL STATIC PRESSURE
L55
POUNDS
SHT
SHEET
ET EXPANSION TANK LWT LEAVING WATER TEMPERATURE SIM SIMILAR
EWB
ENTERING WET BULB TEMPERATURE
MAX
MAXIMUM
EWC
ELECTRIC WATER COOLER
MCA
MINIMUM CIRCUIT AMPACITY
EWT
ENTERING WATER TEMPERATURE
MECH
MECHANICAL
EXH
EXHAUST
MFR
MANUFACTURER
EXST
EXISTING
MIN
MINIMUM, MINUTE
F
FILTER
MOP
MAXIMUM OVERCURRENT
PROTECTION
FC
FAN COIL
MTO
MOUNTED) (INC)
FCO
FLOOR CLEANOUT
NC
NORMALLY CLOSED
FO
FLOOR DRAIN
NG
NATURAL GAS
FF
FINISHED FLOOR
NIC
NOT IN CONTRACT
FLR
FLOOR
NO
NUMBER OR NORMALLY OPEN
FM
FLUSHOMETER
NOM
NOMINAL
FOB
FLAT ON BOTTOM
OD
OUTSIDE DIAMETER/DIMENSION
POT
FLAT ON TOP
OA
OUTSIDE AIR
FRD
FIRE DAMPER
P
PUMP
FRP
FI5ERGLAS5 REINFORCED PLASTIC
PF
PLUMBING FIXTURE
FSD
FIRE t SMOKE DAMPER
PH
PHASE
FT
FEET, FOOT
PIC
PORTABLE INSTRUMENT
CONNECTION
GAL
GALLON
POC
POINT OF CONNECTION
CUH
CABINET UNIT HEATER
GALV
CV
CONTROL VALVE
GPM
D
DRAIN
HC
DCW
DOMESTIC COLD WATER
HPDE
DG
DOOR GRILLE
HP
DHU
DEHUMIDIFICATION UNIT
HT
DI
DUCTILE IRON
HVAC
DIA
DIAMETER
HW
DN
DOWN
HWP
ADDRESS
550 MAIN STREET, SEATTLE, WA 98020
PROPERTY OWNER:
GALVANIZED
GALLONS PER MINUTE
HEATING COIL
HIGH DENSITY POLYTHYLENE
HEAT PUMP
HEIGHT
HEATING, VENTILATION
AND AIR CONDITIONING
HOT WATER (DOMESTIC)
HEATING WATER PUMP
BUILDING INFO
MIKE MCMURRAY, SEATTLE-SNOHOMISH MILL COMPANY, INC
533 5TH AVE S
EDMONDS, WA 98020
GECK08080@GMAIL.COM
(425) 263-2474
PROPERTY TAX ACCOUNT NUMBER
004342-120-015-00 AND 004342-120-017-00 (BEING
COMBINED UNDER SEPARATE APPLICATION
PRV
PRESSURE REDUCING VALVE
PSI
POUNDS PER SQ INCH
F'SIG
POUNDS PER SQ INCH GAGE
PVC
POLYVINYL CHLORIDE
R
RADIUS, RISER, RETURN
RA
RETURN AIR
RAD
RETURN AIR DAMPER
SL SLOPE
SMACNA SHEET METAL AND AIR
CONDITIONING CONTRACTORS
NATIONAL ASSOCIATION
SP STATIC PRESSURE
SR SUPPLY REGISTER
SS STAINLESS STEEL
5TL STEEL L WORK SUBAL
T
TO
TG
TSP
TYP
UR
V
VAC
VAV
VD
VTR
W
WC
WCO
WG
WH
WF D
YCO
MC
EC
TEE OR TANK
TRENCH DRAIN
TRANSFER GRILLE
TOTAL STATIC PRE.. 'a
TYPICAL
URINAL
VALVE, VOLT, VENT
VACUUM
VARIABLE AIR VOLUME
VOLUME DAMPER
VENT THROUGH ROOF
WASTE
JECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
WATER COLUMN OR
WATER CLOSET
WALL CLEANOUT
WATER GAGE
WATER HEATER
WATER PRESSURE DROP
YARD CLEANOUT
MECHANICAL CONTRACTO
ELECTRICAL CONTRACTOR
APPROVE
PROJECT GENERAL NOTES (APPLIES TO ALL SHEETS
1. THIS PROJECT IS BASED ON A DESIGN BUILD CONCEPT & DEPICT SCOPE, EQUIPMENT, CAPACITIES,
ZONING, GENERAL ROUTING & ARE INTENDED FOR PERMIT APPLICATION. THEY ARE DEVELOPED FOR
EXCLUSIVE USE OF DB SOLUTIONS & THEIR SUBCONTRACTORS ONLY. COORDINATION/SHOP DRAWINGS
WILL BE DEVELOPED AS REQUIRED FOR INSTALLATION AND IN CONJUNCTION WITH OTHER TRADES AND
THE EXISTING ARCHITECTURAL AND STRUCTURAL BUILDING ELEMENTS. COORDINATION AND
PLACEMENT OF EQUIPMENT AND SYSTEMS SHALL INCLUDE CONSIDERATION FOR MAINTENANCE,
CEILING HEIGHTS, LIGHTING AND ELECTRICAL CLEARANCES.
2. THE INSTALLATION OF THIS PROJECT IS BASED ON THE 2018 VERSION OF ALL BUILDING, PLUMBING,
MECHANICAL STATE & LOCAL CODES ALL EQUIPMENT& PIPING SHALL BE INSTALLED IN ACCORDANCE
WITH ALL STATE, LOCAL AND APPLICABLE CODES. PROVIDE SEISMIC RESTRAINTS, HANGERS &
SUPPORTS AS REQUIRED.
3. ALL PLUMBING SYSTEMS ARE PRESCRIPTIVELY DESIGNED BASED ON REQUIREMENTS AND METHODS
OUTLINED IN UNIFORM PLUMBING CODE CHAPTERS 2 THRU 11.
4. MAINTAIN A COMPLETE SET OF CLEAN DRAWINGS ON SITE WITH "RED -LINE" MARK-UPS OF ANY FIELD
MODIFICATIONS. DRAWINGS WILL BE PROVIDED TO OWNER AT END OF PROJECT FOR "RECORD
AS-BUILTS".
5. ELECTRICAL SERVICES, PERMITS AND DRAWINGS SHALL BE BY THE ELECTRICAL CONTRACTOR AS
REQUIRED FOR INSTALLATION OF WORK.
6. ALL SYSTEMS SHALL BE COMMISSIONED IN ACCORDANCE WITH WASHINGTON STATE ENERGY CODE & A
REPORT PROVIDED TO LOCAL AUTHORITY UPON REQUEST.
7. CLOSE-OUT DOCUMENTS (I.E. ASBUILTS, O&M MANUALS, DOMESTIC WATER STERILAZATION & Cx
REPORT) SHALL BE PROVIDED TO THE OWNER UPON COMPLETION OF PROJECT.
8. ALL FIRESTOPPING & CAULKING OF PLUMBING PENETRATIONS SHALL BE PROVIDED BY OTHERS.
9. WASTE LINE CLEANOUT SIZING SHALL BE AS FOLLOWS:
4" WASTE PIPE: 4" CLEANOUT WITH 31/2" PLUG.
3" WASTE PIPE: 3" CLEANOUT WITH 21/2" PLUG.
2" WASTE PIPE: 2" CLEANOUT WITH 11/2" PLUG.
10. PIPING MATERIAL SHALL BE AS NOTED IN THE PIPING MATERIAL SCHEDULE ON SHEET P0.01.
11. DOMESTIC WATER PIPING LOCATED OUTSIDE OF THE DWELLING UNITS WILL BE INSULATED
W/MICRO-LOK INSULATION. THICKNESS OF INSULATION WILL BE REQUIRED BY UPC & WASHINGTON
STATE ENERGY CODE, SEE PIPE INSULATION SCHEDULE ON SHEET P0.01.
12. ROOF DRAIN RAINWATER & STORM SYSTEMS ARE PROVIDED BY OTHERS.
13. ALL FLOOR DRAINS TO BE PROVIDED WITH MECHANICAL TRAP PRIMERS, SEE SCHEDULE.
14. FIRE SPRINKLER CONTRACTOR WILL FURNISH AND INSTALL ALL FIRE SERVICE LINES & D.C.V.A.
15. DOMESTIC POTABLE WATER SYSTEM SHALL BE DISINFECTED AND SANITIZED AS REQUIRED BY UNIFORM
PLUMBING CODE SECTION 609.9. FINAL REPORT SHALL BE PROVIDED UPON REQUEST OF THE
AUTHORITY HAVING JURISDICTION (AHJ).
PLANS MUST b
RD
ROOF DRAIN
GC
GENERAL CONTRACTOR
R3
RETURN GRILLE
PC
PLUMBING CONTRACTOR
11=(;01 r11=QrDIDTIr)KI
LOTS 15 AND 16, BLOCK 120, CITY OF EDMONDS
ADDITION, ACCORDING TO THE PLAT THEREOF,
RECORDED IN VOLUME 2 OF PLATS, PAGE 39, RECORDS
OF SNOHOMISH COUNTY, WASHINGTON.
AND;
LOTS 17, 18, 19 AND 20, BLOCK 120, CITY OF EDMONDS
ADDITION, ACCORDING TO THE PLATE THEREOF,
RECORDED ION VOLUME 2 OF PLATS, PAGE 39, RECORDS
OF SNOHOMISH COUNTY, WASHINGTON.
ON JOB SITE
Hot water tanks installed in an A
occupancy shall be inspected by L and I
pressure vessel division. Tank shall be
approved prior to plumbing final.
City Of Edmonds
Building Department
Work PLUMBING FOR T/I
Address 558 MAIN ST 11200
---------------------------------------- --
Owner JOHNNY MO S
Approved Date::_ 01 /27/2023
Building Official Elrl li Ct�.
Permit Number BLD2023-0058
II 4 n Q
v' o o v
v
° o >
3
Q
M-SITE
Q
X Y9 = a
Ewa„E�,p V
VICINITY MAP
MAIN STREET
a',
ENTRY
i
i
i
i
i
ALLEY
-------------------------------------------------------------------------------------------
1 SITE PLAN
).00 J SCALE :1 /16 = I - - 0"
REV1
REV2
REVISIONS
Building Department
REV3
REV4
REV5
PLUMBING SHEET LIST
P0.00 Title Sheet, Bldg Info, Legend & Abbreviations
PO 01 Plumbing Schedules / Calculations
IP0.02 Plumbing Riser Diagrams - Gas, Sanitary & Domestic Water
P1.00 Underground Plumbing Plan
P1.10 Level 1 Plumbing Plan
P1.20 Level 2 Plumbing Plan
P1.30 Roof Level Plumbing Plan
w
Q
U-111
CD
T
0
x
�
�
v
ft
ft
LA
�
}3
o
0
rn
o
C
T
w,
f
36534
�ZGI\ STEM
�10NAL t
U)
z
O
w
U)
o
_
0
�
D
w
U)
W
N
N
O
N
N
N
T_
,ECEIVED
Jan 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
07
a�
z
06
O
C6
Q
O
N
E
C�
�
0)
N
O
NCD
N
0
>E a)
N
J
00
0
rn
m
N
U)
>Q
CU
U)
U)
2
O
O
Lo
LU
DATE
12/27/2022
DRAWN
CHECKED
MTW
DB
PROJECT NO.
DRAWING NO.
P0.00
OF
Plumbing Fixture Calculations
Updated:
12/27/2022
SYMBOL/
KITCHEN # DESCRIPTION
Number
W/V
Cold Water Hot Water
Remarks
Fixtures
DFU (EA) DFU (Total) FU (EA)
FU (Total) FU (EA)
FU (Total) GPM (EA)
GPM (Total)
GPH (EA)
GPH (Total)
FS-1
Floor Sink
5
3 15 --
-- --
-- --
3 --
-- --
-- -
-- --
-- --
--
--
--
6
Ice well w/cold plate
1
Indirect to FS-1
--
--
--
--
7
Soda Dispenser
3
-- --
1
--
--
--
8
Drink Pickup Tray drain
1
Indirect to FS-1
--
--
--
--
--
--
9
Drain Board Drain
3
Indirect to FS-1
--
--
--
--
--
--
--
--
10
Mixing Rail drain
1
Indirect to FS-1
--
--
--
--
--
--
--
--
11
Jockey Cold Rail drain
1
Indirect to FS-1
--
--
--
--
--
--
--
--
12
Mixology Station
1
Indirect to FS-1
1
1
1
1
1
1
5
5
13
Hand Sink
1
1 1
1
1
1
1
1
1
5
5
14
Dump Sink
1
Indirect to FS-1
2
2
2
2
1
1
10
10
15
Glass Washer
1
Indirect to FS-1
--
--
3
3
1
1
20
20
18
Beer Taps w/drain & rinse
1
Indirect to FS-1
1
1
--
--
--
--
--
--
45/46
Hand Sink
2
1
1 2
1
2
1
2
1
2
5
10
61/63
Pre -Rinse Sink & faucet
1
2
2
2
2
2
2
2
2
45
45
64
Dishwasher
1
Indirect to FS-1
--
--
3
3
8
8
40
40
65/67
3 Compartment Sink & faucet
1
6
6
3
3
3
3
2
2
20
20
70
Refer Blower (Condensate)
1
Indirect to MS #80
--
--
--
--
--
--
--
--
80/81
Mop Sink
1
3 1 3
3
3
3
3
2
2
20
20
85
Ice Machine
1
Indirect to FS-1
Indirect to FS-1
1
1
--
--
--
--
--
--
86
Ice Storage Bin drain
1
--
--
--
--
--
--
--
--
88/89
Prep Sink & Faucet
2
Indirect to FS-1
3
6
3
6
2
4
5
10
Totals
--.
Based on Table 703.2, a 4" service is rated for 256
DFU's (vertical) & 216 DFU's (horizontal) at 1/4"/L.F. slope.
At 1/8"/L.F. slope, a 4" service is rated for 173 DFU's.
29 25 26
4" Cold Water Service Demand
Total Fixture Units:
Total GPM required:
Available Pressure (STATIC):
24 185
CW
51 WSFU's
30 GPM
80 psi
HW Tank (HWT) Sizing
See A.O. Smith Water Heater
Selection Report on this sheet.
26
WSFU's
Domestic Water Service (MINIMUM):
18
GPM
2" Service @ 8 FPS = 300 Fixture Units or 80 GPM
Pressure requred at Fixture:
35 psi
1-1/4"
Pipe Size @ 5 FPS
CW piping shall be sized for a maximum flow of 8 fps.
Pressure loss due to elevation, see calc's:
10 psi
1/2"
HWC
HW piping shall be sized fro a maximum flow of 5 fps.
Pressure loss in piping & valves, see calc's:
10 psi
HWT sizing is based on ASHRAE 2019 Applications Chapter 51.
Pressure loss thru meter & RPBP:
0 psi
Total pressure required to serve fixtures:
55
(CeSmith.
Innovation has a name.
A. O. Smith
Phone: 1.866.362.9898
www.hotwater.com
Pressure difference between available vs. losses:
Project Information
Project #: 22-053 Prepared for: DBS
Project Name: Johnny Mo's
Location: Edmonds, WA Prepared by: MTW
Engineer: BCE/MTW
Contractor: DBS
Selected Product
BTH-199 Mxi
Cyclone@ Mxi Modulating
# Heaters:
1
Model Number:
BTH-199 Mxi
Heater Storage (ea):
100 USG
Input (ea):
199,000 Btu/hr
New External Tanks: 0
Tank Capacity (ea): 0 USG
Total Usable Storage: 70 USG
Pro -Size Selection Report
Heater Recovery: 261 USGPH @ 90 °F Rise
1 st Hour Delivery: 331 USGPH
3 Hour Average: 284 USGPH
Est. Storage Recovery: 23 min
% Of Demand: 102% �comm
Model Number
Hi Cube Trailer
Gallon
Recovery
Capacity GPH
Input BTU/HR
Height
Diameter
ApproShipping
Load Factor
Capacity
100 Degree Rise
Weight (Ibs.)
BTH-199 Mxi
2.78
100
235
199,000
76
27.75
523
• Standard and Low profile concentric vent available
• Vents with PVC, CPVC polypropylene and AL-29- •
4C Stainless steel
• Venting distances of up to 120' on all models
• Meets or exceed the thermal efficiency and /or
standby loss requirements of the U.S. Department .
of Energy and current edition of ASHRAE/IESNA
90.1 .
• Meets NSF requirement's (no leg kit needed)
Application Loads
Summary
Peak Demand: 325 USGPH
Application Settings
Up to 98% Thermal Efficiency
Down -Fired Low-NOx Powered -Burner Design
Fully Submerged, Spiral -Shaped Condensing Heat
Exchanger
Complies with SCAQMD Rule 1146.2
Sidewall and Vertical power vent and direct Vent
Options
Space -Saving Design, with Zero Clearance to
Combustibles
Temperature Rise: 90 °F
Type:
Food Service / Restaurant
Building Use:
Not Specified
Cold Water Temp:
50 °F
Peak Demand Period:
1.00 Hours
Stored Water Temp:
140 °F
Equipment:
Water Heaters Only (no external
Approx. Storage:
25%
storage)
# Storage Tanks:
Not Specified
Fuel Type:
Natural Gas
Existing Storage:
None
Location:
Indoor
December 27, 2022
I
The A. O. Smith Pro -Size sizing program is a tool that can be used to estimate water heater requirements for many common applications. Pro -Size is intended to assist in selecting
water heaters or boilers that best meet the specific job requirements. It is the sole responsibility of the system designer to select the correct products needed for the specific application.
A. O. Smith reserves the right to make changes to Pro -Size without notice.
Page 1 of 2
25 psi
KITCHEN PLUMBING EQUIPMENT FIXTURE SCHEDULE Date: 12/27/2022
SYM DESCRIPTION WASTE VENT DFU CW HW WSFU GAS GAS REMARKS
MBTU See Note 1
6 Ice well w/cold plate
7 Soda Dispenser (x3)
1"
--
--
--
--
--
--
--
Indirect sink drain to FS-1
--
--
1
1/2"
--
1
--
--
8
Drink Pickup Tray drain
1"
--
1
--
--
--
--
--
Indirect sink drain to FS-1
9
Drain Board Drain (0)
1"
--
1
--
--
--
--
--
Indirect sink drain to FS-1
10
Mixing Rail drain
1/2"
--
1
--
--
--
--
--
Indirect sink drain to FS-1
11
Jockey Cold Rail drain
1"
--
1
--
--
--
--
--
Indirect sink drain to FS-1
12
Mixology Station
1-1/2"
--
1
1/2"
1/2"
1
--
--
Indirect sink drain to FS-1
13
Hand Sink
2"
1-1/2"
1
1/2"
1/2"
1
w/ASSE 1070 compliant
thermostatic mixing valve
14
Dump Sink
2"
1-1/2"
2
1/2"
1/2"
2
--
--
15
Glass Washer
1"
--
3
--
3/4"
3
--
--
Indirect sink drain to FS-1
18
Beer Taps w/drain & rinse
1"
--
1
1/2"
--
1
--
--
Indirect sink drain to FS-1
44
Double stack oven (x2)
HandSink (x2)
--
--
--
--
--
--
3/4"
240
w/ASSE 1070 compliant
thermostatic mixing valve
45/46
2"
1-1/2"
1
1/2"
1/2"
1
61/63
Pre -Rinse Sink & faucet
2"
1-1/2"
2
1/2"
1/2"
2
--
--
64
Dishwasher
1"
--
3
--
3/4"
3
--
--
Indirect sink drain to FS-1
65/67
3 Compartment Sink & faucet
2"
--
6
3/4"
3/4"
3
--
--
70
Refer Blower (Condensate)
1/2"
--
1
--
--
--
--
--
Indirect sink drain to FS-1
80/81
Mop Sink
3"
2"
3
1/2"
1 1/2"
3
--
--
85
Ice Machine
2"
--
1
3/4"
--
1
--
--
Indirect sink drain to FS-1 & RP-1
86
Ice Storage Bin drain
2"
--
1
--
-- -- -- --
1/2" 3 -- --
I
Indirect sink drain to FS-1
88/89
Prep Sink & Faucet (x2)
2"
--
2
1/2"
Indirect sink drain to FS-1
NOTES:
1 Equipment on this list is provided by others, connections are by plumbing contractor, see Kitchen Sheet K-2.
Dishwasher specs have not been provided as part of
the review. Equipment with direct chemical injections
shall be connected to a RPBA at the point of
appliance connection.
Hot water tanks installed in an A occupancy shall be
inspected by L and I pressure vessel division. Tank
shall be approved prior to plumbing final.
L
5
-
A
CD
T
+r
�
u3
rq
�
�
v
�
v
o
o
Lr
�
t=j
36534
�EGII STEM
y10NAL ES
In
H
Z
W
O
ILL.
—
0
>
LU
D
LI J
U7
U,
N
N
O
N
N
C\V
T_
.ECEIVED
Jan 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
U)
c
O
L
O
�--+
U
E
Ca
U
>
N
N
06
O
_
cn
>
N
O
J
.,
CO
M
Q
v)
W
CM
CM
,�ui
�
O
0
co
u7
Lu
DATE
12/27/2022
DRAWN CHECKED
MTW DB
PROJECT NO.
CONTRACT DRWG. REF.
DRAWING NO.
P0.01
OF
C3�
O
N
C'7
N
O
N
"G (2PSU, 480
1/2 "G (2PSI),199 MW
F�
GAS SOLENOID VALVE, "NORMALLY CLOSED GAS PRESSURE REGULATOR
POWERED OPEN". INTERCONNECT w/FIRE ALARM w/RELIEF VENT THRU ROOF
SYSTEM TO CLOSE UPON SIGNAL. (TYPICAL)
I f ROOF
2 V�11/4' G, 480 MBH) .
r
199 MBH
GAS METER 4 PRIMARY SERVICE
BY UTILITY COMPANY.
GAS COCK/VALVE (TYP)
FLEX CONNECTION (TYP)
PIZZA OVEN 044
3/4 "G,120 MBH
(TYP OF 4)
FULL SIZE x 61. DIRT LEG (TYP)
I" G, 240 MBH)
LEVEL 2
LEVEL I
GAS PIPING RISER DIAGRAM
NO SCALE
l1/z"V (1) TO �-
HANDSINK 045
2"VTR (22 DFU)
2"V (12)
2V (3) TO MOP
SINK w
}
01
65
lx�
2"W (b)
POINT OF CONNECTION TO OU
EXISTING 4" GREASE WASTE
4"GW
(12 DFU)
Gw --/
EXISTING 4" GREASE WASTE
TO EXISTING SITE GREASE
INTERCEPTOR
2"V (3) TO
FS-1 FOR %4
2"V (b)
2"V.(4)
GAS PIPING CALCULATIONS NOTES:
I. PRIMARY GAS PIPING (METER TO PRESSURE REGULATOR) SIZING IS BASED ON
2018 IFGC TABLE 12162(2) SCHEDULE 40 METALLIC PIPE FOR 2 PSI 4 1& W.C.
PRESSURE DROP. THE EQUIVALENT LENGTH OF PIPING IS 100'.
2. SECONDARY GAS PIPING (DOWNSTREAM OF PRESSURE REGULATOR) SIZING IS
BASED ON 2018 IFGC TABLE 121620) SCHEDULE 40 METALLIC PIPE FOR
PRESSURE LESS THAN 2 PSI 4 OV WL. PRESSURE DROP. THE EQUIVALENT
LENGTH OF PIPING IS 50'.
3. SEE PIPING SCHEDULE ON SWEETP0.01 FOR PIPING MATERIALS.
4. PIZZA OVENS REQUIRE A 6 TO 14 WL. GAS SERVICE TO APPLIANCE
REGULATOR, VERIFY wAGTCHEN CONTRACTOR
rl, I1/2 "V (1) TO
HANDSINK 045
11/2"V (2) TO
M PREP SINK +161
2' W
(3)
LEVEL I
GREASE WASTE RISER DIAGRAM
2"CW SHUT-OFF VALVE
4 SERVICE (50 WSFU)
POINT OF CONNECTION TO & V/4"CW (30)
EXISTING 2" DOMESTIC WATER---
I"HW-140F (23)
T4P VALVE wA:ILL SIZE —
RELIEF PIPED TO MOP SINK
SIESMIC RESTRAINTS
PER UPC (TYPICAL
v
'/2"H4CW (1), SET c�
DISCH FOR IIOT-
GWH-1 TO BE INSTALLED ON WALL SHELF. J
COORD w)GL. FOR SHELF 4 LOCATION.
PROVIDE w/DRAIN PAN 4 DRAIN PIPING
TO MOP SINK BELOW.
l 1 0' o
o
T 'o
� � n
+r Ln
CD rq
u
^ 1"CW(12)
UNION (TYP)�� xa^ "-�' 2 "HNC
CHECK VALVE (TYP)CIA
0 I"HW-140F lll)
SHUT-OFF VALVE (TYP)
at 3/4"CW(11)
�z 11
I"WW'I{-Y114�0F (10)
I �
3 LA
-- - --- -- -- - f- -- -- -- 3/4°HW 120 '4) o
--1�/4"CW l29) - - I I i I I 4 3/4"14W-140 (3)
ROUTED BELOW �� �^ �^ a^ «� �^ �� a^ «� „�'� 'iz"CW (1) T
COUNTER SEE
FLOOR PLANS 12 13 14 15 IS
1
'/2"144CW (U, � I �------- --�{ -'---� -----}------- -ice
SET DISC 4 3/4" CW (8)
i I ET I/s"H4CW (U, I I I I I
FOR IIOT- '/z
HWC I
1/(�)a SET DISGH s I s I s s I s I 3i4"HW-14OF (1) I I -- 3i4"HW-120F (4)
I pF AS
FOR 110'F 81 bl 89 64 61 46 w/DR41N TO FS-1
LEVEL 2 , ' �^�"' I RP 4--CW (3) 3
89 /4"14W-14OF (3) e (TYPICAL)
-�
---------- ---- '/,"CW (1)
36534
7
IST _
�`r _ mac. _ moo.
X ♦ m�� ♦ �.r 0,- x �SSI ONAL
DOMESTIC WATER RISER DIAGRAM
NO SCALE
W4
W-i
h
W.
o[�
12
95
WE
_2
v
_R
WE
_
^
POINT OF CONNECTION TO M 211W
EXISTING 4" SANITARY (3) 2" SANITARY
3"SAN 3"SAN 311SAN 2 "SAN
(10 DFU) (9) (6) (3)
EXISTING 4"W (4 DFU)
EXISTING 4" SANITARY
LEVEL I
KITCHEN SANITARY RISER DIAGRAM
EXISTINCs 4" 5ANITART
BAR AREA SANITARY RISER DIAGRAM
U)
H
z
w
o_
O
u-
—
0
�
Z
w
U)
c/)
w
N
N
O
N
r—
N
C\V
T-
.ECEIVED
Jan 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
^L
W
m
U
- -_1
U)
O
E
O
0
06
i
m
.E
C/)
L:
U)O
M
0
N
i
u)
W
N
E
>
N
N
ca.>
i�
N
J
00
L
U)
O
a)Q
r�
Cn
cm
cm
,�
)
m
0
E
E
O
00
Lo
E
Ln
Lu
DATE
12/27/2022
DRAWN
CHECKED
MTW
I
DB
PROJECT NO
CONTRACT DRWG. REF.
DRAWING NO.
P0.02
0F
NO SCALE
NO SCALE
NO SCALE
q12
15"-61/ " 24'- 8 1/ 1 "_011
UNDERGROUND PLUMBING PLAN
SCALE: 1/4" = 1'-0"
4' O 1 /2"
l 1
rn
o
o
CD
T
�
+r
'o
�
n
Ln
rq
�
N
N
�
�
v
u
�
v
LA
4
v
O
rn
fk
O
O
T
v5
�
�
4I11�; R
h1Y
36534
�ZGI\ STEM
�10NAL t
U)
H
Z
W
O
LL
—
0
>
Lu
D
W
U)
N
N
O
N
I-
N
C\V
T-
.ECEIVED
Jan 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
L
O
1�
E
aD
>
N
N
N
a�
o
E
J
co
_Z3
c:
O
�--.
d7
E_
N
E
�
O
oLo-0
Z)
0-
Lu
DATE
12/27/2022
DRAWN CHECKED
MTW I DB
PROJECT NO.
PROJECT
NORTH
CONTRACT DRWG. REF.
DRAWING NO.
0 2' 4' 8' 16' P1.00
DRAWING SCALE: 1/4" = 1'-0" (UNLESS NOTED OTHERWISE) 0F
LEVEL 1 PLUMBING PLAN
SCALE: 1/4" = 1'—O"
7
l 1
rn
o
o
T
�
+r
'o
�
n
Ln
rq
�
N
N
�
�
v
u
�
v
c
ft
ft
LA
4
}3
0
rn
n
o
o
T
u;
�
4I11�; R
AN
36534
�EGI\ STEM
�10NAL V
U)
W, 2°V (3)
~
z
'W(U045
w
O
4ANDSINK
d
—
O
L
—
0
�
Z)
w
"CO, 2"V (3)
U
�
N
N
O
N
r—
N
N
T-
PW(3)#80 RECEIVED
Jan 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
AW
M WINT
PROJECT
NORTH
0 2' 4' 8' 16'
DRAWING SCALE: 1/4" = l'-0" (UNLESS NOTED OTHERWISE)
i
O
N
E
o
N
>
0
N
N
CD
>
N
0
m�
a)Q
_�
cm
>
E
Op
Lo
Lu
DATE
12/27/2022
DRAWN
CHECKED
MTW
DB
PROJECT NO.
CONTRACT DRWG.
REF.
DRAWING NO.
P1.10
OF
9 10 11 12 13
I I I I I
I I
I I
- - - - - - - - - - - - - - - - - - - - - - - -I- - - - - - - -
- - - - - - - - - --- - - - - - - - - - - - - - -I- - - - - - - -
I I
I I
I I
2"V (3), ROUTE PIPING BELOW CABINET
2"V (1) HOLD TIGHT TO WALL
4 CORNER COORDINATE wK
FOR FNGLOSl1RE_
ri1
0
0
N
C`7
N
O
N
\
LEVEL 2 PLUMBING PLAN
- - - - - - - - - - - - - - - - --
A.1
A.8
C.21
V2"CW 4 HW-140F, 2"V (3)
/&a 11/4" H4CW (26 WSFU)
w/34" 144CW TO MOP SINK
N (3)
81 r2�f-,(3)13)
— 3/4"HWC LTOaMV-1, SEE DIAGRAM
ON SHEET P0.02
—11/4"CW (29) w/I1/4"CW (26) TO EWH-I
- D.4
�- 3/4" CONDENSATE PIPING
E.5
CONFIRUCTION NOTE5:
iO GAS SOLENOID VALVE. CONNECT TO FIFE ALAIRM SYSTEM TO
CLOSE UPON SIGNAL.
O ROUTE 2" GAS (4W MBH) TO METER
3O 211V (22 DFU) UP TO VTR.
O3-COMP SINK wK3) 211W CONNECTIONS 4 CLEANOUTS ROUTED TO
GREASE WASTE SYSTEM.
O ROUTE SERVICES DOWN WALL 4 OFFSET BELOW WINDOW TO SERVE
FIXTURE.
OLOOP HW-120F SERVICE DOWN TO HANDSINK 4 CONTINUE AS
INDICATED.
O 2" DOMESTIC COLD WATER SERVICE w/SHUT-OFF VALVE, 50 WSFU.
CONNECT TO EXISTING BUILDING 2" CW SERVICE, VERIFY LOCATION
ON -SITE.
gOROUTE 1/2"HW-140F DOWN 4 CONNECT 1/2"CW TO TMV-1. SET
DISCHARGE TEMP TO 1107 4 CONNECT TO HAND SINK
O34 PVC FLUE 4 COMBUSTION AIR UP TO CONCENTRIC ADAPTER AT
'ROOF. ROUTE TO GWH-I CONNECTIONS.
10 3/4" MED PRESSURE 2PSI GAS SERVICE TO GWH-1 (199 MBH).
PROVIDE w/SHUT-OFF VALVE, PRESSURE REGULATOR w/VENT TO
ROOF, FLEX CONNECTION 4 6" DIRT LEG, SEE DIAGRAMS ON P001.
II GAS PRESSURE REGULATOR w/VENT TO ROOF, SEE DIAGRAMS ON
PO.01. 4W MBH, 2PSI TO (VWC (VERIFY DISCHARGE PRESSURE
FOR PIZZA OVENS wAQTCHEN CONTRACTOR
PROJECT
NORTH
0 2' 4' 8' 16'
DRAWING SCALE: 1/4" = 1'-0" (UNLESS NOTED OTHERWISE)
l 1
0'
o
o
CD
T
�
+r
'o
�
n
Ln
x
�
N
N
�
�
v
u
LA
t=j
36534
�EGI\STEM
�10NAL tS
U)
H
z
w
0-
-
O
L
-
o
�
D
w
U)
N
N
O
N
I-
N
N
T-
.ECEIVED
Jan 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
i
O
N
E
o
N
>
0
N
N
>
CD
N
J
co
m�
o
�Q
C/
cm
N
•�
EO
�
J
_
r2
�
W
�
DATE
12/27/2022
DRAWN CHECKED
MTW DB
CONTRACT DRWG. REF.
DRAWING NO.
P 1.20
OF
9 10 11 12 13
I I I I I
I I I I I
I I I I I
I I I I I
— — — — — — — — — — — — — — — — — — — — — — —I— — — — — — — — — — — — — — — — — — — — — — — — -t — — — — — — — — — — — -t — — — — — — — — — — — — — — — — — — — — — — — -t — — — — — — — — — — --
- — — — — — — — — -- — — — — — — — — — — — — — — —I— — — — — — — — — — — — — — — — — — — — — — — — —I— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
I I I I
I I I I A.1
EXISTS❑ DRAIKNE
I I I
I I I I
I I I I
I I I I
I I I I
I I I I
i I I
I
I
Do I I
I I
I
I
I
I
I
I I
I I
I I
,02"VTR (1 M)
I
I
I
A:o
I'
�*EF
U-
I
EXI5TING ARGIL �_ O
5GREENING X �� 0
2' FOR
I
I
VW CRAB'w
I I
I I
I
I
I
I
�CI�,STINCx �r�-I
I
u u j
S EXISTIN
R PIPE 5NAFT
I I
ALL o z ti
cl
r
tiro
I
ROOF LEVEL PLUMBING PLAN
7
L0
O
66
O
N
C`7
N
O
N
\
L--- EXISTING
❑LEVAT❑R T❑WER
CE FLAT R❑❑E ASSEMBLY
CC SSUSE MEMBRANE R❑❑❑S❑ ❑/
TAPERED CCD INSUC 7" MIN, (R-38 MIN,)
CLASS —A RATED RC7N❑ LAYER
1/2" PCYW❑❑D DECK ❑/
2X CPR DECKS❑ ❑/
❑CB PURCINS ❑N STEEL BEAMS
c.2
MECHANICAL EQUIPMENT ACCESS
— D.4
SEXISTS❑ C❑LS❑
C❑NDENSER
-EXISTING DRAINAGE
E.5
S❑UTHEAST
SCUPPER
-THR❑U❑H
PARAPET
(EXISTING
PROJECT
NORTH
0 2' 4' 8' 16'
DRAWING SCALE: 1/4" = 1'-0" (UNLESS NOTED OTHERWISE)
l 1
�'
o
CD
T
�
+r
�
�
n
Ln
rq
N
N
�
u
LA
o
36534
�EGI\STEM
�10NAL tS
U)
z
w
0
U'
L
-
o
D
W
N
N
O
N
I-
N
NN
.ECEIVED
Jan 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
0
N
0
N
c�
o
N
N
a�
o
cm
E
J
NO
co
Q
>
C
.c:
J
0
2
o
o
O
Lo
-0
0
--.)
Uc,
w
DATE
12/27/2022
DRAWN CHECKED
MTW DB
PROJECT NO.
CONTRACT DRWG. REF.
DRAWING NO.
P1.30
OF