REVIEWED BLD2023-0054+Manufacturer_Specifications_and_Installation_Instructions+1.12.2023_7.05.09_PM+3312982DnUBLF WALL FACTORY BUILT DUCTWORK
- ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW.
- FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE ENTIRE INSTALLATION AND OPERATION MANUAL
- DUCTWORK SHALL SLOPE NOT LESS THAN 1/16' PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR.
- WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16' PER LINEAR FOOT.
HORIZONTAL
DUCT DIAMETER
SUPPORT SPACING (FT)
5'
7'
6'
7'
7'
7'
8'
7'
10,
7'
12,
7'
14'
7'
16'
7'
18,
5'
20'
5'
22,
5'
24'
5'
26'
5'
28'
5'
30'
5'
32'
5'
34'
5'
36,
S'
VERTICAL
TYPE
WALL
SUPPORT (FT>
CURB
SUPPORT (FT)
FLOOR
SUPPORT (FT)
2R & 2R HT (5'-16')
20,
24'
24'
2R (18')
Is,
24'
24'
& 3Z (5'-24')
1
10'
24'
24'
3Z C26' -36')
10'
20'
20'
D❑ NOT LEAK TEST USING SMOKE BOMBS C❑NTAINING
CHL❑RINES/CHL❑RIDES. CONSULT WITH CAPTIVEAIRE
FOR PROPER LEAK TESTING METHODS,
DUCTWORK #1 FRONT VIEW
JOB Johnny Mo's Pizza - Edmonds WA
LOCATION Edmonds, WA, 98020
O�DATE 10/25/2022-TOB 570
i��-
wir
DWG 1 6 DRAWN BY JDC
DUCTWORK #1 SIDE VIEWDUCTWORK #1 TOP VIEW
f� 21.50' 39.05'
I P18 I I 18 I
P4 P3 P5 P7I.P9
P17 P17
=39'01'-"
DUCTWORK #1 SE VIEW
130'MAX 129'MAX
103.5' 102.5'
90.5'MIN 89.5'MIN
191,5'MAX
139.5'
114.5'MIN
P15
P4 P3 P5 L P7
,1.5'MAX 39.0 '
36'
24'MIN P2
PI
12 228' 22.51' 16.51' 16.51'
90.35'
1'iA131717X.9RIZILNX 419[onII1I411090JE
191.5'MAX
139,5'
114.5'MIN
129'MAX
102.5'
89.5'MIN
1 P16
P15
P12 EM
P4
P3
61.5'MAX 61.5'MAX 61.5'MAX P5
36' 36' 36'
P13 24'MIN 24'MIN P2 24'MIN
P2
P14 P1
IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL
EQUIPMENT HAS HAD A COMPLETE START UP PER THE OPERATION AND INSTALLATION MANUAL,
TYPICALLY, THE SDV WILL BE PERFORMED AFTER ALL INSPECTIONS ARE COMPLETE.
ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO
THE
ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES
WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS
TO
RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND
BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED
DISCREPANCY THAT CANNOT BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP
CHARGES.
DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE
MANUFACTURER, SHOULD A RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND APPROPRIATE
SALES OFFICE WILL BE NOTIFIED. THERE WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER
DISCREPANCIES,
M
N
6
0
N
t' J
N
0
N
\
P9
P12
P13
P14
JOB Johnny Mo's Pizza - Edmonds WA
LOCATION Edmonds, WA, 98020
DATE 10/25/2022 JOB # 5700745
-ir - DWG A 7 DRAWN BY JDC-85
LOCATION Edmonds, WA, 98020
��- - =_� DATE 10/25/2022 JOB 5700745
w�
DWG d 8 DRAWN BY JDC-85
DUCTWORK 8f PARTS - JOBd5700745 DOUBLE WALL
TAG
PART #
CFM
GPM
ZONE
CDVEREDBY
SP
WEIGHT
VELOCITY
QTY
DESCRIPTION
P1
DW06RISER
0.98
1
SINGLE WALL DUCT RISER FOR WELDED HOODS, 6' DIA DUCT. STAINLESS STEEL,
DOUBLE WALL ADJUSTABLE DUCT - 6' INNER DUCT - 2 LAYERS REDUCED CLEARANCE - 10,
P2
DWO647DWAJD-LR-S
51.69
1
STAINLESS STEEL OUTER SHELL. MIN LENGTH = 11' / MAX LENGTH = 50.5' / ADJUSTMENT =
32.5' / ADJUSTABLE SECTION MAY NEED TO BE CUT. INCLUDES SINGLE AND DOUBLE WALL 'V'
CLAMPS.
P3
OW06DWTEASY-2R-S
1
14,74
1
DOUBLE WALL DUCT - 6' INNER TEE DUCT - 2 LAYERS REDUCED CLEARANCE - 10,
ASSEMBLED V/P4
STAINLESS STEEL OUTER SHELL.
P4
DW06DVACCDOORCOV-2R-S
11.89
1
DOUBLE WALL DUCT - 6' INNER ACCESS DOOR & 10' ACCESS DOOR COVER WITH CLAMPS - 2
ASSEMBLED W/P3 O=S
LAYERS REDUCED CLEARANCE - 10' STAINLESS STEEL OUTER SHELL.
P5
DW06070WLT-2R-S
4.57
1
DOUBLE WALL DUCT - 6' INNER DUCT, 7' LONG - 2 LAYERS REDUCED CLEARANCE - 10'
STAINLESS STEEL OUTER SHELL.
P6
DW0608DWRNDADPEC2ASY-2R-S
9.12
1
COULD NOT DRAW,
P7
DW08DWTEASY-PR-S
1
21.48
1
DOUBLE WALL DUCT - 8' INNER TEE DUCT - 2 LAYERS REDUCED CLEARANCE - 12'
STAINLESS STEEL OUTER SHELL.
P8
DW0608DWRNDADPEC2ASY-2R-S
9.12
1
COULD NOT DRAW.
P9
DW0607DWLT-2R-S
4.57
1
DOUBLE WALL DUCT - 6' INNER DUCT, 7' LONG - 2 LAYERS REDUCED CLEARANCE - 10'
STAINLESS STEEL OUTER SHELL.
DUCT - HORIZONTAL SADDLE SUPPORT KIT, USED WITH 10' OD - INCLUDES UNI-STRUT CUT TO
P10
DW1014SADKIT
4.58
1
LENGTH, 12 GRADE 5 HEX NUTS, 8 GRADE 5 WASHERS. PARTS PULLED FROM PLANT
INVENTORY.
DUCT - HORIZONTAL SADDLE SUPPORT KIT, USED WITH 10' OD - INCLUDES UNI-STRUT CUT TO
P11
DW1014SADKIT
4.58
1
LENGTH, 12 GRADE 5 HEX NUTS, 8 GRAVE 5 WASHERS. PARTS PULLED FROM PLANT
INVENTORY,
P12
DWO690DWASY-2R-S
10.42
1
DOUBLE WALL DUCT - 6' INNER 90 DUCT - 2 LAYERS REDUCED CLEARANCE - 10' STAINLESS
STEEL OUTER SHELL.
DOUBLE WALL ADJUSTABLE DUCT - 6' INNER DUCT - 2 LAYERS REDUCED CLEARANCE - 30'
P13
DWO647DWAJD-2R-S
51.69
1
STAINLESS STEEL OUTER SHELL. MIN LENGTH = 11' / MAX LENGTH = 50.5' / ADJUSTMENT =
32.5' / ADJUSTABLE SECTION MAY NEED TO BE CUT. INCLUDES SINGLE AND DOUBLE WALL 'V'
CLAMPS.
P14
DW06RISER
0.98
1
SINGLE WALL DUCT RISER FOR WELDED HOODS, 6' DIA DUCT. STAINLESS STEEL.
P15
DWO823DWLT-2R-S
19.51
1
DOUBLE WALL DUCT - 8' INNER DUCT, 23' LONG - 2 LAYERS REDUCED CLEARANCE - 12'
STAINLESS STEEL OUTER SHELL.
DOUBLE WALL ADJUSTABLE DUCT - 8' INNER DUCT - 2 LAYERS REDUCED CLEARANCE - 12'
P16
OW0847DWAJD-2R-S
63.04
1
STAINLESS STEEL OUTER SHELL. MIN LENGTH = 11' / MAX LENGTH = 50.5' / ADJUSTMENT =
32.5' / ADJUSTABLE SECTION MAY NEED TO BE CUT. INCLUDES SINGLE AND DOUBLE WALL 'V'
CLAMPS.
P17
OV084550DWLTTP-2R-S
38.44
1
DOUBLE WALL DUCT - 8' INNER DUCT, 45.5' LONG - 2 LAYERS REDUCED CLEARANCE - 12'
ASSEMBLED W/P18
STAINLESS STEEL OUTER SHELL - USED WITH TRANSITION PLATE.
PIB
OW1906TP
6.62
1
DUCT TO CURB TRANSITION, 19-1/2' CURB TO 8' DUCT, 16 GA ALUMINIZED STEEL. MISC.
ASSEMBLED W/P37
NON-STANDARD TRANSITION PLATE. FOR USE WITH EXHAUST FAN.
3M-2000PLUS
0.80
3
DUCT - 3M FIRE BARRIER 2000 PLUS SILICONE - USED AS SEALANT TO SEAL DUCT JOINTS.
DW06CLASY
0.39
2
DUCT 'V' CLAMP, 6' DUCT WITH NEW DESIGN 14 GA SLOTTED BRACKETS, 2 PIECE, ASSEMBLY.
OV06DVCLASY-2R-S
3.87
4
DUCT - 6' DUCT - 10' DOUBLE 'V' CLAMP - 2R INSULATION & SINGLE 'V' CLAMP INCLUDED
- REDUCED CLEARANCE.
DW08DWCLASY-SR-S
4.93
3
DUCT - 8' DUCT - 12' DOUBLE 'V' CLAMP - 2R INSULATION & SINGLE 'V' CLAMP INCLUDED
- REDUCED CLEARANCE.
ADDITIONAL PARTS
SINGLE WALL DUCT RISER WITH RETAINING RINGS, 8' DUCT, USED ON FIELD INSTALLATIONS.
Field Riser
DWOBFRISER
3.31
2
INCLUDES 1/4-20 HARDWARE (8) NUTS (8) BOLTS - W SINGLE BOTTOM RING (2) TOP RINGS
2 PIECES PER ASSEMBLY.
TOTAL WEIGHT
368.09
JOB Johnny Mo's Pizza - Edmonds WA
AM ��� �� LOCAT70N Edmonds, WA, 98020
���- DATE 10/25/2022 JOB
570
� - -- -- DWG 4 DRAWN BY JDC
O
SINGLE WALL FACTORY BUILT DUCTWORK
- ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW.
- FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE INSTALLATION AND OPERATION MANUAL.
- DUCTWORK SHALL SLOPE NOT LESS THAN 1/16' PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR.
- WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16' PER LINEAR FOOT.
DUCT DIAMETER
HORIZONTAL
SUPPORT <FT)
VERTICAL
WALL SUPPORT (FT)
VERTICAL
CURB SUPPORT (FT)
5'
10,
10,
24'
6'
10,
10,
24'
7'
10,
10,
24'
8'
10,
10,
24'
10,
10,
10,
24'
12,
10,
10'
24'
14'
10'
10,
24'
16'
10,
10'
24'
18,
10,
10,
24'
20'
10,
10,
24'
22'
10,
10,
24'
24'
10,
10,
24'
26'
10,
10,
24'
28'
10,
10,
24'
30,
10,
10'
24'
32'
10,
10'
24'
34'
10,
10,
24'
36'
10,
10,
24'
JOB Johnny Mo's Pizza - Edmonds WA
n �� a�w �� _ = LOCATION Edmonds, WA, 98020
�luW O� 1 �= DATE 10/25/2022 JOB ¢ 5700745
-- DWG # 5 DRAWN BY JDC-85
FOR QUESTIONS, CALL THE
Seattle Office
REGION 85
PHONE. (425) 212-5996
EMAIL. reg85BcaptWealre.com
FAN
UNIT
TAG
QTY
FAN UNIT MODEL #
MANUFACTURER
CFM
ESP
RPM
MOTOR
HP
BHP
PHASE
I VOLT
ILA
DISCHARGE
WEIGHT
SONES
NO
ENCL
VELOCITY
(LBS)
1
EF
1
CASREI3BD
CAPTIVEAIRE
400
0500
993
ODP
O500
0.1420
1
115
7.6
417 FPM
247
-
FAN
UNIT
NO
TAG
OTY
DESCRIPTION
1
RE13BD - HIGH TEMPERATURE HEAT & SMOKE OPTION
1
UTILITY SET GREASE CUP
1
EXTRA SET OF BELTS
I
EF
1
FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS
I
RE11/13 - RAIN CAP ASSEMBLY - INCLUDES HARDWARE AND GASKET
1
2 YEAR PARTS WARRANTY
EXHAUST
SUPPLY
FAN
UNIT
NO
TAG
GREASE
GRAVITY
WALL
SIDE
GRAVITY
MOTORIZED
WALL
CUP
DAMPER
MOUNT
DISCHARGE
DAMPER
DAMPER
MOUNT
I
EF
YES
NG FAN TAG I EIGHT ITEM SIZE
1 # 1 EF 30 LHS CURB 19.500'W X 19.500'L X 24.000'H ALONG LENGTH, RIGHT VENTED.
I=
AIN CAP OPTION.
34 3/8' a m m 221
JOBJohnny Mo's Pizza - Edmonds WA
__ LOCATION Edmonds, WA, 98020
DATE 10/25/2022 JOB 570
O �I - DWG 0 1 1 DRAWN BY JDC
14 3/4'
f0'
13 7/8' '
!4 7/8'
2l'
TOP VIEW
W13
'
SPRING PIN.19 2' DR4'
DUCTWORK BETWEEN
EXHAUST RISER ON HOOD
AND FAN (BY OTHERS).
19'
19 1/2'
19 1/2'
VENTED
1\ CUR&
20 GAUGE
STEEL
CONSTRUCTION.
3' FLANGE.
` ROOF OPENING
19' DIMENSIONS.
19'
PITCHED CURBS ARE AVAILABLE 0'
FOR PITCHED ROOFS.
0'
SPECIFY PITCH.
12'
EXAMPLE. 7/12 PITCH - 30' SLOPE.
FEATURES:
ROOF MOUNTED FANS.
- RESTAURANT MODEL.
- UL762 AND ULC-S645.
- HIGH HEAT OPERATION BELT DRIVE 500'F (260'0
- HEAT SLINGER.
- GREASE CLASSIFICATION TESTING.
- TILT OUT WHEEL.
- LOCKING PIN FOR POWER PACK.
- MOTOR WEATHER COVER.
- INTERLOCKED DISCONNECT SWITCH.
- NEMA 4X SAFETY DISCONNECT SWITCH.
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING AIR AT 500'1 (260'0
UNTIL ALL FAN PARTS HAVE REACHED
THERMAL EQUILIBRIUM, AND WITHOUT ANY
DETERIORATING EFFECTS TO THE FAN WHICH
WOULD CAUSE UNSAFE OPERATION.
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING BURNING GREASE VAPORS
AT 600'F <3C) 16'FOR A PERIOD OF
15 MINUTES WITHOUT THE FAN BECOMING
DAMAGED TO ANY EXTENT THAT COULD CAUSE
AN UNSAFE CONDITION.
OPTIONS
- RE13BD - HIGH TEMPERATURE
HEAT & SMOKE OPTION. - 572•F
CONTINUOUS.
- UTILITY SET GREASE CUP.
- EXTRA SET OF BELTS.
- FAN BASE CERAMIC SEAL -
INSTALLED AT PLANT - FOR
GREASE DUCTS.
- RE11/13 - RAIN CAP ASSEMBLY
- INCLUDES HARDWARE AND
GASKET.
- 2 YEAR PARTS WARRANTY.
juffionnny mo's rizza - Lamonas w(A
0% ��� -� _ n LOCATION Edmonds, WA, 98020
an AvDATE 10/25/2022 JOB 5700745
- O � I W � - DWG # 2 DRAWN BY JDC-85
Rry I arAT.F z/a' = 1-n
Exhaust Fan Wiring
JOB 5700745 - Johnny Mo's Pizza - Edmonds WA
DRAWING NUMBER EXH5700745-1
SHIP DATE 10/25/2022
MODEL CASREI3BD
Installed Uotions
1
2
Component Identification
3
�BK---
BK
Label Description Location
;WH -__:I n4
WH MT-01
I
R
4
SW-01
-
MT-01 Fan Motor 131
OGR ---�
5
SW-01 Main disconnect switch 131
6
7
8
9
10
11
12
13
14
15
16
MOTOR INFO
EXHAUST 0.5HP-115V-1P-7.6FLA
17
18
ELECTRICAL�NFIIRMATION
MOP.
MOTOR/CTRJ�L 1.
19
20
NOTES
- DENOTES FIELD WIRING
21
DENOTES INTERNAL WIRING
22
WIRE COLOR
BK - BLACK YW -YELLOW
BL - BLUE GR - GREEN
BR - BROWN GY - GRAY
23
OR - ORANGE PR - PURPLE
RD - RED PK - PINK
WH - WHITE
U-1
C)
A
CD
T
4 �
'0
LA
441A
�
'4
O
4d'i
yO
}
C
C
J
N
Lfi
4
Y
Fk
O
C7
r
L+1
�
36534
�EGI�STE�
�10NAL ES
U)
LU
LL
-
0
LL
-
0
LU
Z)r^
W
VJ
N
N
O
N
\
ti
N
(N
r
BLD2023-0054
ECEIVED
Jan 12 2023
CITY OF EDMONDS
)EVELOPMENT SERVICES
DEPARTMENT
VJJ
/
O
r�
V J
E
N
N
p
>
N
bi
Q
J
00
E
vJ
^�,,
i
M
I^,
W
�M
'^
V!
>
>
O
Lo
-0
_
_
�
L J
LU
DATE
12/27/2022
DRAWN 7DB
CKED
MTW
=1f31x0M.I.a
CONTRACT DRWG. REF.
DRAWING NO.
M2.10
OF