Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2023-0630+Manufacturer_Specifications_and_Installation_Instructions+5.23.2023_10.57.44_AM+3563478
APPROVEDLANS MUST CU-1 ® BLD2023-0630 P ON JOB SITE E TRANE REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENTI RECEIVED.................................................................................. The following documentation shall be available on Submiftal site for the building inspector: May 23 2023 IN— APPROVED ARCHITECTURAL PLAN SET CITY OF EDMONDS ! ® COE APPROVED STRUCTURAL PLAN SET DEVELOPMENT SERVICES ' F-JCOE REVIEWED CALCULATION PACKET DEPARTMENT ENERGY CREDIT WORKSHEET ❑ SITE PLAN ❑ CIVIL PLAN ;® Manufactures Secs. :D .......... i iiE.DiIii i . i1i.Ni DiPiiiiliii:............ I 5 Ton Split System Cooling — 3 Phase 4TTA3060D � 7IPAME Note: "Graphics in this document are for representation only. Actual model may differ in appearance." May2020 4TTA3060D—SUB3-1 D—EN � CHNOLOGIES.. NOTE: All dimensions are in mm/inches. Product Specifications ELECTRICAL AND REF COMPONENT CLEAAANC PER PREVAILING CDC TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOA Ai LEAST "" (5 FEETI ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12') FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. 22.2 (7/8) DIA HOL E� LOW VOLTAGE 28.6 (1-1/8) DIA. N.O. WITH 22.2 (7/8) DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY L IOU ID LINE ESERVICE VALVE. T I.D. FEMALE BRAZE H CONNECTION WITH T SAE IF FLARE PRESSURE TAP FITTINGS, 1 J G 1 FIG. 1 N.O. FOR ALTERNATE ELECTRICAL ROUTING `--GAS LINE 1/4 TURN BALL SERVICE VALVE, -D' I.D. FEMALE BRAZED CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTING, From Dwg. D152898 OUTDOOR UNIT @@ 4TTA306OD3000D 4TTA3060D4000D POWER CONNS. — V/PH/HZ (D 208/230/3/60 460/3/60 MIN. BRCH. CIR. AMPACITY 20 10.3 BR. CIR. PROT. RTG. - MAX. (AMPS) 35 15 COMPRESSOR SCROLL SCROLL NO. USED - NO. SPEEDS 1-1 1-1 VOLTS/PH/HZ 200/230/3/60 460/3/60 R.L. AMPS (D - L.R.AMPS 15.6-110 7.8-52 FACTORY INSTALLED START COMPONENTS ® NO NO INSULATION/SOUND BLANKET NO NO COMPRESSOR HEAT YES YES OUTDOOR FAN PROPELLER PROPELLER DIA. (IN.) - NO. USED 27.6 -1 27.6 -1 TYPE DRIVE - NO. SPEEDS DIRECT-1 DIRECT-1 CFM @ 0.0 IN. W.G. ® 4320 4320 NO. MOTORS - HP 1-1/5 1-1/5 MOTOR SPEED R.P.M. 825 825 VOLTS/PH/HZ 200/230/1/60 460/1/60 F.L. AMPS .93 0.6 OUTDOOR COIL —TYPE SPINE FINTIA SPINE FINT"' ROWS-F.P.I. 1-24 1-24 FACE AREA (SQ. FT) 24.93 24.93 TUBE SIZE (IN.) 3/8 3/8 REFRIGERANT LBS. — R-410A (O.D. UNIT) OO 8 LBS., 8 OZ. 8 LBS., 8 OZ. FACTORY SUPPLIED YES YES LINE SIZE - IN. O.D. GAS © 7/8 7/8 LINE SIZE - IN. O.D. LIQ. © 3/8 3/8 CHARGING SPECIFICATION SUBCOOLING 10°F 10°F DIMENSIONS H X W X D H X W X D CRATED (IN.) 42.4x35.1 x38.7 42.4x35.1 x38.7 WEIGHT SHIPPING (LBS.) 261 261 NET (LBS.) 226 226 (DCertified in accordance with the Air -Source Unitary Air -conditioner Equip- ment certification program, which is based on AHRI standard 210/240. Oz Rated in accordance with AHRI standard 270. OO Calculated in accordance with Natl. Elec. Codes. Use only HACK circuit breakers or fuses. ® Standard Air — Dry Coil — Outdoor *This value approximate. For more precise value see unit nameplate. © Max. linear length 60 ft.; Max. lift - Suction 60 ft.; Max lift - Liquid 60 ft. For greater length consult refrigerant piping software Pub. No. 32-3312-0" (' denotes latest revision). This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. ® No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. MODELS BASE FIG. I A I B I C I D I E I F I G I H I J I K 4TTA3060D 1 4 1 1 943 37-1/8 946 37-1/4 870 34-1/4 7/8 1 3/8 1 152 6 98 3-7/8 219 8-5/8 86 3-3/8 508 20 A -WEIGHTED SOUND POWER LOVEL [dB(A)] MODELS SOUND POWER LEVEL [dB(A)] A -WEIGHTED FULL OCTOAVE SOUND POWER LEVEL Db - [dB(A)] 63 125 250 500 1000 2000 4000 8000 4TTA3060D3 75 80 73 70 72 71 65 63 59 4TTA306OD4 80 47.3 55.7 69 72.7 75.8 69.4 62.2 53.3 Note: Rated in accordance with AHRI Standard 270-2008 Mechanical Specification Options General Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evapora- tive coil match. This unit is designed to operate at outdoor ambient tempera- tures as high as 115°F. Cooling capaci- ties are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, G90 galvanized steel and painted with a weather -resistant powder paint on all louvers, panels, prepaint on all other panels. Corrosion and weather- proof CMBP-G30 DuraTuffTm base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The Climatuff° compressor features internal over temperature and pressure protection and total dipped hermetic motor. Other features include: roto lock suction and discharge refrigerant con- nections, centrifugal oil pump and low vibration and noise. Condenser Coil The Spine Fin TM coil shall be continu- ously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 5/16 inch O.D. seamless aluminum glued to a continuous alumi- num fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this unit has a cool- ing capability to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV per- mits low ambient cooling to 30°F Accessories Thermostats — Heating/Cooling (manual and automatic changeover). Sub -base to match thermostat and lock- ing thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Outdoor Thermostat — Supplemen- tal heat outdoor ambient lockout from 46 to —10°F. Trane - by Trane Technologies (NYSE: TT), a global climate innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane.com or tranetechnologies.com. c � L u s LISTED The AHRI Certified mark indicates Trane U.S. Inc. participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4TTA3060D-SUB3-1 D-EN 01 May 2020 Supersedes 4TTA3060D-SUB3-1 C-EN (October 2019) 0 2020 Trane Submittal Upflow / Horizontal Left/Right Single Stage Condensing Gas Fired Furnace 100,000 BTU H Upflow, Convertible to Horizontal Right or Horizontal Left S9X1C10005PSBA S9B1C10005PSAA Note: Graphics in this document are for representation only. Actual model may differ in appearance. May2020 S9X1 C1000-SUB-1 D-EN N U) (9 _x _n O O C C W r!n Z 20-I I16 5,8 4-5116 20-1/4 WITH REAR E1.1,"YEP SLUE 10-B 116 OUTLET I 16eiie G OUTLET z1-1n6 XEXNGUP AIR Upflow Furnace INLET C Size Cabinet ' -- ----------- 20-11- 7-3/16314 PNUGGEO NONN I OT USED UPPLONI NOT USED IN UPELON 5-,8 ? S 9UYPLY I-,/B I-118 (ALTERXATEI D -sl8 GAS SUPPLY -I/1 2-SIB 0y ELECTRICAL WIRES dl-3l8 I-3/0 CONDENSATE TRAP (NOR IZONTAL RIGHT) UE INLET 0 3 (HORIZONTAL LEFT) (HORIZONTAL A'MT) ¢7l8 ELECTRICAL WIRES �3 IALTERXAT[I COX DE XSATE TRAP I NORIZOFLUE LEETI 3 FLUE INLET FLUE OUTLET NOA IZOX3AL RIGHT) (HORIZONTAL LEFT) {D -Sl8 ❑ ¢ LTERN CON0ENSA'E OAAIX CONDENSATE OAAIN UPE LOW( 33 31 ALTERXAiEI {81I8 28-I116 ¢7l8 iNE ANOS1Ai WIRES 28-I/I6 AITUNENXAT[IWIRES - 35-S116 34 PI1116 PIA 21-IIll6 25-I14 19 SIDEs DE 14-3IB R E T U R N 8 e IB-3116 R E T U R N II-3/0 LA I R 13-111 11-sn6 A I R L L 1 -114 I� IG-5/I6 5/I6 a 2C 14 311 21-3/16-I Sll6 1-Sll6 IB-SI I6 L 13116 DOOR DESIGN MAY VARY 28-3 /4 NAS 1-5/16 1-13I11 PILOT DIMPLE POfl FLUE OUTLET (NOR IZONTAL RIGHT ALTERNATE) 10-114 1NLET AIR va 20� Oa CD rf N C CD v `J CD �• CQ N Product Specifications MODEL S9X1C10005PSBA (a) S9B1C10005PSAA TYPE Upflow / Horizontal RATINGS (b) Input BTUH 100,000 Capacity BTUH (ICS) (c) (d) 97,400 Temp. Rise (Min. -Max.) 40 - 70 AFUE (%) S9X1 / S9B1 (d) 95.0 / 92.1 Return Air Temp. (Min. - Max.) 45OF - 80OF BLOWER DRIVE DIRECT Diameter— Width (In.) 11 X 10 No. Used 1 Speeds (No.) (e) 9 CFM vs. in. w.g. See Fan Performance Table Motor HP 1 RPM 1075 Volts/Ph/Hz 120 / 1 / 60 FLA 10 COMBUSTION FAN — Type Centrifugal Drive — No. Speeds Direct - 1 Motor HP — RPM 3300 Volts/Ph/Hz 120 / 1 / 60 FLA 0.66 FILTER — Furnished? No Type recommended High Velocity Hi Vel. (No.-Size-Thk.) 1 — 20x25 — 1 in. VENT PIPE DIAMETER — Min (in.) (f) (g) Round 2 HEATEXCHANGER Type — Fired 409 Stainless Steel — Unfired 29-4C Stainless Steel MODEL S9X1C10005PSBA (a) S9B1C10005PSAA Gauge (Fired) 20 ORIFICES — Main Nat. Gas Qty. — Drill Size 5 - 45 LP Gas Qty. — Drill Size 5- 56 GAS VALVE Redundant - One Stage PILOT SAFETY DEVICE Type 120 V SiNi Igniter BURNERS — Type Multiport Inshot Number 5 POWER CONN. — V/Ph/HZ (h) 120 / 1 / 60 Ampacity (In Amps) 13.3 Max. Overcurrent Protection (Amps) 15 PIPE CONN. SIZE (in.) 1/2 DIMENSIONS H x W x D Uncrated (In.) 34 x 21 x 28-3/4 Crated (In.) 35-1/2 x 23 x 30-7/8 WEIGHT Shipping (Lbs.)/Net (Lbs.) 155/145 (a) Meets Energy Star (b) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. (c) Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3. (d) Based on U.S. government standard tests. (e) 9 Speed constant torque ECM blower motor (f) Refer to the Vent Length Table in the Installer's Guide. (g) All furnace models have a vent outlet diameter that equals 2 in. (h) The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. S9X1 C1000-SUB-1 D-EN Airflow tables Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SUM 1013 847 680 514 348 Watts 104 116 129 142 155 2 SUM 1261 1126 990 854 718 Watts 168 185 202 219 236 3 SCFM 1519 1407 1296 1184 1072 Watts 267 290 313 336 358 4 SUM 1554 1446 1337 1229 1120 Watts 283 307 330 353 377 5 SUM 1749 1651 1554 1457 1359 S9X1C100U5PSBA S9B1C10005PSAA Watts 385 411 436 462 488 6 SUM 1868 1778 1688 1599 1509 Watts 464 491 519 546 574 7 SUM 2018 1936 1853 1770 1688 Watts 573 602 631 660 689 8 SUM 2191 2112 2033 1954 1875 Watts 718 750 782 815 847 9 SUM 2395 2303 2212 2120 2028 Watts 966 981 996 1012 1027 CFM Versus Temperature Rise Table 2. Heating Table — Upf low CFM VS. TEMPERATURE RISE MODEL 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 S9X1C10005PSBA S9B1C10005PSAA 65 61 57 55 53 49 46 44 43 S9X1C1000-SUB-1D-EN General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control is a solid state device which continuously monitors for presence of flame when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICK HEATING Durable, cycle tested, heavy gauge tubular stainless steel primary heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas with LP conversion kit. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. S9X1 also contains dry contacts for EAC and HUM. ENERGY EFFICIENT OPERATION S9X1 Furnace is certified by the manufacturer to leak 1 % (1.4% for S9131 ) or less of nominal air conditioning CFM delivered when pressurized to .5" water column with all inlets, outlets, and drains sealed. I_111111a4W4:i7 The 9 tap constant torque ECM blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. SECONDARY HEAT EXCHANGER The S-Series furnace has a special type 29- 4CT11 stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost. STYLING Heavy gauge steel and "wrap -around" cabinet construction is used in the cabinet with baked -on enamel finish for strength and beauty. Every orientation has at least two venting options. There are no knockouts on cabinet. FEATURES AND GENERAL OPERATION The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switches. S9M C1000-SUB-1 D-EN Features and Benefits UP TO 96.0% AFUE ON S9X1 FURNACE MODELS Meets utility rebates Lowers utility bills ELECTRICALLY EFFICIENT Efficient airflow design reduces electrical energy use 34 INCH TALL Lighter, easier to move and fit into tight spaces like short basements or tight closets Works great with larger, high -efficiency coils No knockouts 3—WAY MULTI -POISE / DEDICATED DOWNFLOW 6 SKU's — Upflow / Horizontal Left / Horizontal Right 5 SKU's — Downflow Added application flexibility and reduction in specification errors AIRFLOW At least 400 CFM/ton at 0.5 in. H2O external static pressure; setup airflow options down to 290 CFM/ton REGULATORY All models are airtight; 1% or less air leakage as per ASHRAE 193 0.4% for S9131) Open vestibule design provides a full 34" high open vestibule 911u1:1►69us] 6*1 Width is industry standard: 21" Depth remains approximately 28" Cabinet is compatible with industry standard coils as well as other accessories INTEGRATED FURNACE CONTROL Setup / Status / Diagnostics / Digital Display No dip switches Last six errors stored Dry contact EAC and HUM connections on S9X1 models All Molex connections; no spade terminals Low voltage labeled above and below Rain shield over IFC keeps condensate off the control TUBULAR STAINLESS STEEL PRIMARY HEAT EXCHANGER 29-4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Stainless steel is a more durable, corrosive -resistant material than aluminumized steel Integrated rail system for easy access if required Reduces or eliminates need for baffles VORTICA II BLOWER, DESIGNED EXCLUSIVELY FOR THE S-SERIES FURNACE Improved airflow efficiency Durable, easy to clean, two piece housing Single piece belly band/ motor arm assembly Blower deck has full-length rails for easy removal and replacement, regardless of poise THREE—WAY MULTI -POISE (UPFLOW, HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED DOWNFLOW Easier to specify Shipped ready to install (no conversion kits required) Every model has at least two venting options When in horizontal, trap extends only about 2" Barbed fitting on trap at hose connection and on cabinet transition for hose has barbed fitting and clamps at both ends for leak resistance. Vent table improvements including longer vent lengths 6 SM1 C1000-SUB-1 D-EN About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com. 0%.us Intertek The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. S9X1C1000-SUB-1D-EN os May202O Supersedes S9X1C1000-SUB-1C-EN (November2019) ©2020 AC-1 4TXC-DS-SUB-26-EN 1.5 - 5 ton Coils, Split System Aluminum Premium Heat Pump / Cooling Coils 4TXC Series Coils PRODUCT SPECIFICATIONSt'14TXC-DS --- HIGH EFFICIENCY STAGED SPLIT SYSTEM HEAT PUMP / COOLING COMFORT TM COILS -- CASED UPFLOW / DOWNFLOW/ HORIZONTAL 4TXCA002DS3HCB 4TXCB003DS3HCB 4TXCA032DS3HCB 4TXCB004DS3HCB 4TXCC005DS3HCB INDOOR COIL -- Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity (Tons) 1.5 - 2.0 1.5 - 2.5 2.5 - 3.0 3.0 - 3.5 3.0 - 3.5 Rows/F.P.I. 2/20 3/14 2/20 3/12 3/12 Face Area (sq.ft.) 3.0 3.5 4.5 5.0 5.0 Tube Size 3/8 3/8 3/8 3/8 3/8 Refrigerant Control Non -Bleed TXV Non -Bleed TXV Non -Bleed TXV Non -Bleed TXV Non -Bleed TXV Internal check valve Yes Yes Yes Yes Yes Drain Conn. Size (in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing REFRIGERANT R-410A R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED BRAZED Line Size Gas (in.) 3/4 3/4 3/4 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 3/8 3/8 DIMENSIONS (in.) H X W X D H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 21-9/16 x 18-1/2 x 27-1/2 21-9/16 x 21-1/2 x 27-1/2 26-9/16 x 18-1/2 x 27-1/2 26-9/16 x 21-1/2 x 27-1/2 26-9/16 x 25 x 27-1/2 Uncrated 17-1/2 x 14-1/2 x 21-1/2 17-1/2 x 17-1/2 x 21-1/2 22-1/2 x 14-1/2 x 21-1/2 22-1/2 x 17-1/2 x 21-1/2 22-1/2 x 21 x 21-1/2 WEIGHT (Ibs) 42 / 34 50 / 42 49 / 41 58 / 50 60 / 52 Shipping -- Net 4TXCB006DS3HCB 4TXCC007DS3HCB 4TXCD008DS3HCB 4TXCC009DS3HCB 4TXCD010DS3HCB INDOOR COIL -- Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity (Tons) 3.5 - 4.0 3.5 - 4.0 3.5 - 5.0 3.5 - 5.0 3.5 - 5.0 Rows/F.P.I. 3/14 3/14 3/14 3/16 3/16 Face Area (sq.ft.) 5.5 6.0 6.0 7.0 7.0 Tube Size 3/8 3/8 3/8 3/8 3/8 Refrigerant Control Non -Bleed TXV Non -Bleed TXV Non -Bleed TXV Non -Bleed TXV Non -Bleed TXV Internal check valve Yes Yes Yes Yes Yes Drain Conn. Size (in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing REFRIGERANT R-410A R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED BRAZED Line Size Gas (in.) 7/8 7/8 7/8 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 3/8 3/8 DIMENSIONS (in.) H X W X D H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 30-13/16 x 21-1/2 x 27-1/2 30-13/16 x 25 x 27-1/2 30-5/8 x 28-1/2 x 27-1/2 34-3/4 x 25 x 27-1/2 34-3/4 x 28-1/2 x 27-1/2 Uncrated 26-3/4 x 17-1/2 x 21-1/2 26-3/4 x 21 x 21-1/2 26-3/4 x 24-1/2 x 21-1/2 30-3/4 x 21 x 21-1/2 30-3/4 x 24-1/2 x 21-1/2 WEIGHT (Ibs) 63 / 55 69 / 61 72 / 64 78 / 70 81 / 73 Shipping -- Net [1] These indoor coils are A.H.R.I. certified with various split system air conditioners and heat pumps (A.H.R.I. Standard 210/240). Refer to the Split System Outdoor product information site or www.ahrinet.org X C) b cn c W N D7 rl Z Outline Drawing for models: 4TXCA002DS3HCB, 4TXCB003DS3HCB, 4TXCA032DS3HCB, 4TXCB004DS3HCB, 4TXCC005DS3HCB, 4TXCB006DS3HCB, 4TXCC007DS3HCB, 4TXCD008DS3HCB, 4TXCC009DS3HCB, 4TXCD010DS3HCB z-3/X °o 29/0 1 lle— °o o O o o 0 o 5-3/0 2-1/2 A A 0 0 O-I/0 I-3/1 1/0 1 T I-3/d j T 3-5/8 1-1/0 111JGGEOP SECONOAAY HAIN FOR VERTICAL POSITION O O LUGGEOPSECOXOARY DRAIN POR VEAi ICAL POSITION O O CD 03/4 NPT 3-I 12-311 fOANVERT CAL NPOSI iI ON -IIB rb3/d RPT 3-I 12] 1-311 PRINAAY DRAIN fOR VERTICAL POSITION 19-I/2 OPENING IN WRAPP EA 21 -I 12 _ OPENING IN WRAPPER C OPENING IN WAAPPEA B B From Dwg. D346710 Rev A FIGURE B FIGURE A \ \�`1 MODEL 4TXCA002DS3 4TXCA032DS3 4TXCB003DS3 4TXCB004DS3 4TXCCOO5DS3 4TXCBOO6DS3 4TXCC007DS3 4TXCD008DS3 4TXCC009DS3 4TXCDOIODS3 SEE FIGURE FIGURE A FIGURE A FIGURE B FIGURE A FIGURE A FIGURE A FIGURE A FIGURE A FIGURE A FIGURE A SHIPPING WEIGHT (LBS.) 44 49 50 58 60 63 69 72 78 81 REFRIGERANT CONTROL TXV (NON -BLEED) HEIGHT "A" (IN.) 17-5/8 22-1/2 17-5/8 22-1/2 22-1/2 26-7/8 26-7/8 26-7/8 30-3/4 30-3/4 OVERALL WIDTH "B" (IN.) 14-1/2 14-1/2 17-1/2 17-I/2 21 17-1/2 21 24-1/2 21 24-1/2 OPENING WIDTH "C" (IN.) 13-5/8 13-5/8 16-5/8 16-5/8 20-1/8 I6-5/8 20-1/8 23-5/8 20-1/8 23-5/8 TOP OPENING I'D" 12-3/4 12-3/4 15-3/4 15-3/4 19-1/4 15-3/4 19-1/4 22-3/4 19-1/4 22-3/4 GAS CONNECTION 3/4 7/8 LIQUID CONNECTION 3/8 MATCHED FURNACE WIDTH 14-1/2 14-1/2 17-1/2 17-1/2 21 I7-1/2 21 24-1/2 21 24-I/2 (NO ADAPTER REQUIRED) DRAIN PAN PLASTIC E v 0 ME CL 5i Installer's Guide Mechanical Specifications General Accessories Upflow, Downflow, or Horizontal coils shall be designed for cooling and heat The following TXV accessories may be pump applications. The coil shall be 3/8" seamless aluminum tubing used with these coils as needed. Refer to mechanically bonded to aluminum plate fin. kit installation guide for further details. Refrigerant for the 4TXC Coils factory installed Non -Bleed TXV refrigerant control. Refrigerant connections are brazed fittings. The coil cabinet shall have a removable front and interior access panel for evaporator coil entering air surface cleaning. The coil includes a vertical drain pan with primary and secondary drain connections for vertical operation and a horizontal drain pan with primary and secondary drain connections for horizontal operation. These coils are A.H.R.I. certified. R-22 CONVERSION NON -BLEED TXV KITS Coil R-22 TXV Kit 4TXCA002DS3HCB 4TXCA032DS3HCB 4TXCB003DS3HCB 2AYTXVH3H1836A 4TXCB004DS3HCB 4TXCC005DS3HCB 4TXCB006DS3HCB 4TXCC007DS3HCB 2AYTXVH3H4248A 4TXCD008DS3HCB 4TXCC009DS3HCB 2AYTXVH3H6060A 4TXCD010DS3HCB 4AYTXVH4A1830A Adjustable TXV Kit 4AYTXVH4A3042A Adjustable TXV Kit 4AYTXVH4A4860A Adjustable TXV Kit PRESSURE DROP CHARACTERISTICS FOR COOLING AND HEAT PUMP COILS AIRFLOW (CFM) VS. PRESSURE DROP ACROSS WET COIL PRESSURE DROP (INCHES OF WATER COLUMN) Model 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 4TXCA002DS3HCB 225 340 430 510 585 650 715 775 4TXCA032DS3HCB 375 570 725 860 985 1100 1200 1305 4TXCB003DS3HCB 350 525 665 790 900 1000 1095 1180 4TXCB004DS3HCB 440 655 825 970 1100 1220 1330 1435 4TXCB006DS3HCB 430 640 815 965 1095 1220 1335 1445 4TXCC005DS3HCB 520 770 970 1145 1300 1440 1570 1695 4TXCC007DS3HCB 505 760 965 1140 1300 1445 1580 1710 4TXCC009DS3HCB 490 740 940 1120 1 1280 1425 1565 1695 4TXC D008DS3HCB 580 870 1100 1300 1485 1650 1805 1950 4TXC D010DS3HCB 555 835 1065 1265 1445 1615 1770 1915 4TXC-DS-SUB-2B-EN 3 About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com C P1 US c �- us �,s�o LISTED Intertek The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4TXC-DS-SUB-2B-EN 12 Apr 2021 Supersedes 4TXC-DS-SUB-2A-EN (October 2020) © 2021 Job Name: CLINE JEWELERS System Reference: ERVA Date: FEB 2023 GENERAL FEATURES • Lossnay® cross -flow energy recovery core • Minimal cross contamination between entering and leaving air streams • Stand-alone remote controller (PZ-62DR-EA) • M-NET Connectivity • External input bypass damper control • Stand alone or interlocks connects with all Mitsubishi Electric products • Four fan speeds • High efficiency DC Motor • Standard MERV 7 non -woven fabric filter, washable fiber • Optional high -efficiency MERV 14 and MERV 16 filters Specifications Unit Type Capacity 7 CFM [mYh] Power source Power Consumption kW Current A System ,. 470 [799] 208/230, 1, 60 0.22 - 0.425 0.047/0.11 Starting Current A 6.1 MCA A 5.1 Maximum Overcurrent Protection (MOCP) A 15 Fan Air Volume CFM [m3/h] 118- 235-353-470 [ 200-399-599-7991 Type x quantity 9-5/8 In. diameter centrifugal fan External Static pressure in.WG 0.06-0.25-0.56-1.0 Motor type EC Motor Exchange Efficiency Temperature % 69-73-77.5-84.5 Enthalpy Cooling % 51.0-57.0- 64.0- 72.0 Enthalpy Heating % 64.0-69.0-75.0-83.0 External finish Galvanized steel sheet External Dimensions In. [mm] 41-3/8 x 51-5/16 x 15-29132 [1,051 x 1,302 x 404] Net weight Lbs [kg] 110 [50] Energy Transfer Mechanism Lossnay® Core Heat Exchange Material Partition, spacing plate -cellulose fiber membrane Heat Exchange System Air-to-air total heat (sensible heat + latent heat) exchange, no moving parts Blower Type 9-5/8 In. diameter centrifugal fan Entering Air Temperature Operation Range T ['Cl 14 to 104 [ -10 to 401 Sound pressure level dB(A) 40.0-34.0-26.0-20.0 Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Wired Remote Controller Lossnay® ERV Remote Controller Control Interface Signal Output Terminal Duct Accessories Duct Silencer Filter MERV 14 Filter MERV 16 Filter MERV 7 Filter (Included) Remote Sensor CO2 Sensor, Built -In CO2 Sensor, Wall Mount ❑ PZ-62DR-EA ❑ PZ-4GS-E ❑ PZ-250SS-E ❑ PZ-80RFP-E ❑ PZ-80RFP2-E ❑ PZ-80RF9-E ❑ PZ-70CSB-E ❑ PZ-70GSW-E Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Position where duct direction change is possible 6 1/2' (165) By-pass damper plate Air exhaust fan Ceiling suspension fixture :LESS DOOR/PANEL#2: `n 44 17/32' (1131) (4 - 9 / 16' X 13 / 1 6' (4 - 1 5 X 2 0) o v a I ) i"X52" �2 3 1/32' (77) I C') E A R A (exhaust air autIet) '� �r— ~(return air) + +— iLl 0A ii i�i�ji ii SA (outside air intake ) i� ;i p(supply air) + —� li-- --d L Core, CD0 3 1/32' (77) air filter, `D C_ o Inspection High -Efficiency filter, oo a) N opening fan, _' ,0 1.5ftX1.5ft Air supply fan 1 37/64' (40) maintenance space —� '\ � (450 X 450) dN _ or mare Control box 15 29/32' (404) Maintenance Cover Power supply 6 1/2' (165) Cable opening ACCESS DOOR/PANEL#1: 18"x18" High -Efficiency filter (sold separately) Lossnay core attachment position 45 1/16' 3 1/8' (79) (1144) 3 1/8' (79) v \ j/ � I � o C_ _ M - N m Air filters � LD N N Position where duct direction change is possible M Q7 o UNIT SCALE - a inch(mm) N.T.S FORM# LGH-F470RVX2-E - 202206 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com C ETA �s Intertek Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: CLINE JEWELERS I Schedule Reference: HP-1 (EXISTING) I Date: MARCH 2O23 1 OUTDOOR VRF SYSTEM FEATURES • Single-phase outdoor unit with variable refrigerant flow (VRF) zoning technology • Inverter -driven (variable speed) compressor • Total refrigerant piping length of 394' (120 m) • Uses CITY MULTI indoor units and Controls Network *UNIT OPTION ❑ Standard Model....................................PUMY-P36NHMU ❑ Standard Model...............................PUMY-P36NHMUR4 ❑ Sea Coast (BS) Model....................PUMY-P36NHMU-BS ❑ Sea Coast (BS) Model...............PUMY-P36NHMUR4-BS OPTIONAL PARTS ❑ Joint Kit..............for details see Pipe Accesories Submittal ❑ Header Kit.......... for details see Pipe Accesories Submittal ❑ Air Outlet Guide (One Piece)**......................PAC-SG59SG-E ❑ Wind Baffle (One Piece)**..................................WB-PA2 ❑ Drain Pan................................................PAC-SG64DP-E ❑ Drain Socket........................................PAC-SG61 DS-E ❑ Drain Socket ......................................... PAC-SH71DS-E **PUMY requires two outlet guides and wind baffles for installation. Specifications Model Name Unit Type PUMY-P36NHMU Nominal Cooling Capacity (208/230V) Btu/h 36,000 Nominal Heating Capacity (208/230V) Btu/h 40,000 Operating Temperature Range Cooling (Outdoor) *1 I 23° F - 115° F (-5 ° - +46° C) DB* Heating (Outdoor) I 0° F - +60° F (-18° - +15° C) WB External Dimensions (H x W x D) In. / mm I 53-3/16 x 37-7/16 x 13 (+1-3/16) / 1,350 h x 950 w x 330 (+30) Net Weight Lbs. / kg I 287 / 130 External finish I Precoated Galvanized -steel Sheets Electrical Power Requirements Voltage, Phase, Hertz 208 / 230V, 1-phase, 60Hz Minimum Circuit Ampacity (MCA) A 26 Recommended Fuse/Breaker Size A 30 Maximum Fuse Size A 40 Piping Diameter (Flared) (In. / mm) Liquid (High Pressure) 3/8 / 9.52 Gas (Low Pressure) 5/8 / 15.88 Indoor Unit Total Capacity 50 to 130% of Outdoor Unit Capacity Model / Quantity P06 to P36 / 1 to 6 Sound Pressure Levels dB(A) 49/51 Fan Type x Quantity Propeller Fan x 2 Airflow Rate CFM 3,530 Direct -drive Inverter Motor Output kW 0.086 Compressor Operating Range 41 % to 100% Compressor Type x Quantity Inverter -driven Scroll Hermetic x 1 Compressor Motor Output kW 2.4 Refrigerant R410A Lubricant FV50S High-pressure Protection Device 601 psi / 4.15 MPa Compressor / Fan Protection Device Overheat Protection /Thermal Switch Inverter Protection Device Overheat / Overcurrent Protection AHRI Ratings (Ducted / Non -Ducted) EER 10.75 / 11.20 SEER 14.3 / 14.3 COP 3.56 / 3.14 Blue Fin Anti -corrosion Protection: Cellulose- and polyurethane -resin coating treatment applied to condenser coil that protects it from air contaminants; >_1 pm thick; Salt Spray Test Method - no unusual rust development to 240 hours. NOTES: *1. If PKFY-P06/08 indoor units are connected, then range is 50' F -115' F (10' C - 46' C). SEACOAST PROTECTION -External Panel Base, External Front Panel, Pillar: Alloyed galvanized -steel sheets with thermoset polyester -resin coating on internal and external surfaces -Compressor Cover: Galvanized -aluminum sheets with thermoset polyester -resin coating on internal and external surfaces -Electrical Parts Box: Galvanized -aluminum sheets with thermoset polyester -resin coating on external surface -Fan Motor Support: Galvanized -steel sheets with thermoset polyester -resin coating on internal and external surfaces -Printed Circuit Board: Epoxy resin with polyurethane -coating on external surface Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc. @c o ffno c C y N W CD W ^ in r rn �I 1 ID z `y 0 x CD Rear Air Intake 2-U $raped notched hole ^� (Foundation Bolt M10<W3/8>) c o (D 1 FREE SPACE 13 FOUNDATION BOLT 14 PIPING -WIRING DIRECTIONS W S W K o The diagram below shows a Dimensions of space needed Please secure the unit firmly Piping and wiring connections 600<23-5I6> 3 N (D basic example. for service access are with 4 foundation (M10<yy3/8>) can be made from 4 directions: n Explantion of particular details is shown in the below diagram. bolts.(Bolts and washers must front,right,rear and below. (D NO N given in the installation manuals etc. be purchased locally.) Side Air Intake .. C FREE `� n ^ � 5 O A _ ® <Foundation bolt height> m m C 7 e„ O S> a36 Oval hole c _ FOU ATI N (Foundation Bolt M10<W3/81) lD MIn.10mm<y3> tOmmdlBMi^ . K 2-]l32> - 2a Dischargefi z1 N T V TOiminal clock /r 95Gm,n 3/32> C.nt ..... For the tmn,mi ,i.n l Rear Air Intake Handle 322<12-it/18> ( GR rortrepowiticin ly Center... For thh-n1r ti-tont. MIn.f000mm<393I6>Y--- ( GR madcing positir�r Right.. For concentration control Side Air Intake ` 00 Ghana for the transmission In, Ground for concentration control Handle a 0 0000 Example of Notes O 0000 $ervioepenal 8 1 ra ......Refrigent GAS pipe mnnction (FLARE) a15.88 (518 inch) Handle . _Reflgerant LIQUID pipe connection (FLARE) a9.52 (318 inch) Handle 'i......lndi-b- of STOP VALVE connection location. Handle O o000 5 Air intake 0 0000 1 n d 'b O O . 0000. p Piping Knockout Hole Details Front piping m er/ X Right pi ping hole coedit hde Rear pipingm (Knockout) 12-a —Kmckoutl When installing the conduit. cenduh hale Right kunkin9 role $et the attachment tithe - c (2-o2J<1-1116>Knockod) ( roc ou I inner side of each panel. Front ro <2.3192> 45<1-25132> 49<1A116> Contluilhde { 1 (n trunki�g hole q0<1-9I18> 45<1-25132> g P 2]<1-1/16>Knodwd) 1l2 Cantluil atlacM1ment z O IKnadwuq n ,`� 2-e22<]/6> x O W O I m w "d < \^,y u (Kiwckout)ng M1ole P (Knackout)ng hole C (D O m9j6> VB ea eel D X n O D _ Fro pipin �� ]4<2-1— W W z (Klwckoutl ho m 19<3l4> 55<2-3It6> 92<3E/6 (Knorr kloutl M1ok "' C� W CD C 92<3-Sla> 3 0 I.A N (t) M^� - H i3 ^ N " mmanm> W N v 191 T l91 N d � e ■� Y/ Co' m T D MW —1 ?5V+ z 6) Job Name: I Schedule Reference: FCU-I (EXISTING) I Date: SPECIFICATIONS Capacity* Cooling....................................................30,000 Btu/h Heating....................................................34,000 Btu/h Power ' - Power Source .........................208 / 230V, 1-phase, 60Hz - Power Consumption* Cooling..............................................................0.45 kW Heating.............................................................0.43 kW - Current* - -- _ Cooling.............................................................2.20 / 2.00 A Heating............................................................2.09 / 1.89 A Minimum Circuit Ampacity (MCA) @ 208V..............................................................................2.70 A GENERAL FEATURES @ 230V..............................................................................2.45 A • Dual set point functionality • High external static pressure capabilities • Ducted fan coil supports multiple configurations for flexible installation • Built-in condensate pump; lifts to 27-9/16 inches • Suitable for use in air handling spaces in accordance with Section 18.2 of LIL 1995 4th Edition OPTIONS ❑ Condensate Pump ........ BlueDiamond X87-711/721; 115/230V ❑ Condensate Pump .......... Sauermann S130-115/230; 115/230V ❑ Filter Box (Includes 2" MERV 13 filter) ............................ FBH2-2 ❑ CN24 Relay Kit.................................CN24RELAY-KIT-CM3 Notes: FuseSize...................................................................................15 A External Finish..............................Galvanized-steel Sheet External Dimensions Inches ............................15 H x 40-9/16 W x 35-7/16 D mm..........................................380 H x 1,030 W x 900 D Net Weight...................................................124 lbs. / 56 kg CoilType.................................................................Cross Fin (Aluminum Plate Fin and Copper Tube) Fan Type x Quantity.......................................Sirocco Fan x 2 Airflow Rate (Low -High) .................................... 636-883CFM External Static Pressure @ 208V..............................................................0.40 - 1.00"WG @ 230V..............................................................0.60 - 1.00"WG Motor Type .................................... 1-phase induction motor Refrigerant Piping Dimensions Liquid (High Pressure)..................3/8" / 9.52 mm (Brazed) Gas (Low Pressure)..................5/8" / 15.88 mm (Brazed) Drainpipe Dimension..............................0.D. 1-1/4"/32 mm Sound Pressure Levels Low -High ....................................................38 - 44 d B(A) " Cooling / Heating capacity indicated at operation under the following conditions: Cooling Indoor: 80' F (27° C) DB / 67' F (19' C) WB, Cooling Outdoor 95' F (35' C) DB Heating Indoor: 70' F (21' C) DB, Heating Outdoor 47' F (8° C) DB / 43' F (6° C) WB Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc. p to m aID O A D / r V n m n X# � m� m O m = 7 T1 6 n f V N N � /7 3 f0 WO C m z Cl) m 2 n C C o m (n O N 3 O N O O A O �.: CJt 3 O C O fOD n 0 0 r z Po rn� M 171 �cn cm > M /v0A3 /'" z 2 L1 — 0 0 0 D z m N A 8 U t y _ Air in A I Air utlet d y m` LB 814(32-1/16) 60(2J/8) (Suspension bolt pitch) (Duct) , t 904(35-5/8) m „, (0.13.02(1-1/4)) (0.13.02(1-1/4)) (Gravity drain) (Emergency drain) �0000©ao©o©a®® (Duct) Note 1. Use an M10 screw for the suspension bolt (field supply). 2. Keep the service space for the maintenance from the bottom when the heat exchanger is cleaned. 3.This drawing is for PEFY-P2730 36-48-54NMHU-E2 models, which have 2 fans.PEFY-P15 18 24NMHU-E2 models have 1 fan. 4.Make sure to install the air filter (field supply) on the air intake side. In case field supplied air filter is used, attach it where the filter service is easily done. Required space for service and maintenance. y10"'.t lsl d. M S�f a" I PEFFP151814NMHU£2 ypyp I P2)3pNMHLLE4 y 5616 18"x18" Make the access door at the appointed position properly Ifor service maintenance. — — — — — 300(11-13/16)orless F(Actual length) (Actuallengih) F (Duct) Note 1. Use an M10 screw for the suspension bolt (field supply). 2. Keep the service space for the maintenance from the bottom when the heat exchanger is cleaned. 3.This drawing is for PEFY-P2730 36-48-54NMHU-E2 models, which have 2 fans.PEFY-P15 18 24NMHU-E2 models have 1 fan. 4.Make sure to install the air filter (field supply) on the air intake side. In case field supplied air filter is used, attach it where the filter service is easily done. Required space for service and maintenance. y10"'.t lsl d. M S�f a" I PEFFP151814NMHU£2 ypyp I P2)3pNMHLLE4 y 5616 18"x18" Make the access door at the appointed position properly Ifor service maintenance. — — — — — 300(11-13/16)orless F(Actual length) (Actuallengih) F WhIsne\rWalue' DC" VENTILATION: FAN EF 3-4 (RR) Fv-051 OVS1 Specification Submittal Data / Panasonic Ventilation Fan Description: Ceiling Radiation Damper: Ventilating fan shall be Low Noise ceiling or wall mount type rated for continuous run. Fan shall be ENERGY STAR® rated and certified by the Home Ventilation Institute (HVI). Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: • Enclosed DC brushless ECM motor technology rated for continuous run. • Fan ventilation rates shall be manually adjustable for 50-80-100 CFM. • Power rating shall be 120 volts and 60 Hz. • Fan shall be UL and cUL listed for tub/shower enclosure when GFCI protected and used in insulated ceiling (TYPE I.C.). • PCB board equipped with thermal -cutoff fuse. • Removable with permanently lubricated plug- in motor. Housing: • 26 gauge galvanized steel body. • Built-in 4" Oval duct collar. Also compatible with 4" round duct. • Optional 24 gauge steel, fire code rated 4" oval to 3" round duct adaptor sold separately (Model # FV-VS43R). • Built in backdraft damper. • Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier, and assists with the decrease in leakage in the Building Envelope during blower door testing. • Unique L-shaped bracket simplifies installation and provides strong support. • WhisperValue DC is UL listed for use with the Panasonic Ceiling Radiation Damper (Model #: PC-RD05C5, sold separately). Grille: • Attractive design using Poly Pro material. • Attaches directly to housing with torsion springs. Warranty: • DC Motor: 6 Years from original purchase date. • ALL Parts: 3 Years from original purchase date. Architectural Specifications: Ventilation fan shall be UL and cUL listed for ceiling or wall mount and tub/shower enclosure when GFCI protected. Fan shall also be ENERGY STAR° certified, with a built-in speed selector. Choose from 50-80-100 CFM and no more than <0.3/0.4/0.9 sone as certified by the Home Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge (w.g.) with no less than 53/81/100 CFM and no more than 0.5/0.8/1.3 sone as certified by HVI at 0.25 w.g. Power Consumption shall be no greater than 4.4/7.2/11.1 watts at 0.1 w.g. and 7.5/11.5/16.0 watts at 0.25 w.g., with efficiency of no less than 12.8/11.4/9.2 CFM/watt at 0.1 w.g. and 7.9/7.2/6.4 CFM/watt at 0.25 w.g. The motor shall be totally enclosed with a brushless ECM motor engineered to run continuously. ECM motor speed shall automatically increase when the fan senses static pressure to maintain selected CFM. Power rating shall be Specifications: WhisperValueDC FV-0510VS1 4" Oval 4" Oval 411 Oval Static Pressure in inches w.g. 0.1 t 0.1 1 0.1 Air Volume (CFM) 100 100 80 81 50 53 Noise (sones) 0.9 1.3 0.4 0.8 <0.3 0.5 Ventilation Fan Power Consumption (wafts) 11.1 16.0 7.2 11.5 4.4 7.5 Characteristics Energy Efficiency (CFM/Watt) 9.2 6.4 11.4 7.2 12.8 7.9 (HVI Certified Speed (RPM) 902 1121 797 1 1070 708 1025 Data) Current (amps) 0.20 0.27 0.13 0.20 1 0.09 0.14 MAX. Current (amps) 0.39 Power Rating (V/Hz) 120/60 ENERGY STAR rated YES 0.25=Installed Performance For complete Installation Instructions visit us.panasonic.com/ventfans FV-051 OVS1 120V/60Hz. Duct diameter shall be no less than 4". Optional 24 gauge steel, fire code rated 4" oval to 3" round duct adaptor sold separately (Model # FV-VS43R). Fan can be used to comply with ASHRAE 62.2, LEED, EarthCraft, California Title-24 and WA Ventilation Code. WhisperValue Contractor Pack* The Contractor Pack includes four complete fans. The housing and motor/grille are packaged separately for flexibility during installation. Housing Can Motor/Grille Assembly Fan Un it Pack FV-051OVSA1 I FV-0510VSB1 FV-0510VS1i 4 *Must order in quantities of 4. Shipment will contain 1 box with 4 units Performance Curve 4" Oval duct 0.80 0.60 --FV-051M1 4"du f50CFM --N-0510VS1 4"duWW CFM 3 0.50 - FV-0510VS1 4"duct/100CFM -4" 20ft duct 12 12 a 0.40 0.30 - -G 401 door ••••C 60ft duct U -4" SOft duct N N 0.20 --4"100ft duct 0.10 a.o0 0 20 40 60 80 100 Airflow (CFM) / 1 v, 1 . t Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: Panasonic Eco Solutions North America ECM Motor Technology Eco Products Division �iv When the fan senses static pressure, its speed is automatically increased to ensure Two ark, NJ 0 Plaza that the desired CFM is not compromised, which allows the fan to perform as rated. Newark, NJ 07102 us.panasonic.com/�ventfans Vlo c �L us Girr:l VF16549SS0517 Panasonic wpN hserCeiling•DC- \VENTILATION': FA EF-5 BREAK ROOM] FV-1115VQ1 Specification Submittal Data / Panasonic Precision Spot Ventilation Fan Description: Ventilating fan shall be Low Noise ceiling mount type rated for continuous run. Fan shall be ENERGY STAR® rated and certified by the Home Ventilation Institute (HVI). Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: • Enclosed brushless ECM motor technology rated for continuous run. • Fan ventilation rates shall be manually adjustable for 110-130-150 CFM. • Power rating shall be 120 volts and 60 Hz. • Fan shall be UL and cUL listed for tub/shower enclosure when GFCI protected aRel Hseel • Motor equipped with thermal -cutoff fuse. • Removable with permanently lubricated plug- in motor. Housing: • 26 gauge Zinc -Aluminum -Magnesium (ZAM) housing. • Integrated 6" duct adapter. • Built-in damper reduces back drafting and helps with blower door testing. • Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier, and assists with the decrease in leakage in the Building Envelope during blower door testing. • Articulating and expandable installation bracket up to 24". Ceiling Radiation Damper: • WhisperCeiling® DC'" is UL listed for use with the Panasonic Ceiling Radiation Damper (Model #: PC-RD05C5, sold separately). Grille: • Attractive design using Poly Pro material. • Attaches directly to housing with torsion springs. Warranty: • ECM Motor: 6 Years from original purchase date. • ALL Parts: 3 Years from original purchase date. Architectural Specifications: Ventilation fan shall be UL and cUL listed for ceiling mount and tub/shower enclosure when GFCI protected. Fan shall also be ENERGY STAR° certified, with a built-in speed selector. Choose from 110-130-150 CFM and no more than <0.3/<0.3/<0.3 sone as certified by the Home Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge (w.g.) with no less than 110-131-152 CFM and no more than <0.3/0.5/0.7 sone as certified by HVI at 0.25 w.g. Power Consumption shall be no greater than 6.8/9.0/11.8 watts at 0.1 w.g. and 12.1/15.7/20.2 watts at 0.25 w.g., with efficiency of no less than 16.4/14.7/12.9 CFM/ watt at 0.1 w.g. and 9.2/8.5/7.6 CFM/watt at 0.25 w.g. The motor shall be totally enclosed with a brushless ECM motor engineered to Specifications: WhisperCeiling DC FV-1115VQ1 6" 6" 6" Static Pressure in inches w.g. 0.1 1 0.1 0.1 1 Air Volume (CFM) 150 152 130 131 110 110 Noise (sones) <0.3 0.7 <0.3 0.5 <0.3 <0.3 Ventilation Fan Power Consumption (watts) 11.8 20.2 9.0 15.7 6.8 12.1 Characteristics Energy Efficiency (CFM/Watt) 12.9 7.6 14.7 8.5 16.4 9.2 (HVI Certified Speed (RPM) 698 925 671 918 636 900 Data) Current (amps) 0.19 0.31 0.16 1 0.25 0.12 0.20 MAX. Current (amps) 0.31 Power Rating (V/Hz) 120/60 ENERGY STAR rated Yes 0.25=Installed Performance For complete Installation Instructions visit us.panasonic.com/ventfans 6" Duct run continuously. ECM motor speed shall automatically increase when the fan senses static pressure to maintain selected CFM. Power rating shall be 120V/60Hz. Duct diameter shall be no less than 6". Fan can be used to comply with ASHRAE 62.2, LEED, ENERGY STAR° IAP, EarthCraft, CA Title 24 and WA state code. Performance Curve 6" Duct 0.60 o.eo 3 V01 ;SFM t o.ao 13- y1,lICFM m 0.30 a` 6^ don ever N0.20 fi"80X duct duct -8" 10DX tluR o.m 0 20 40 60 e0 100 120 14 160 Airflow (CFM) Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: Panasonic Eco Solutions North America ECM Motor Technology Eco Products Division When the fan senses static pressure, its speed is automatically increased to ensure Two rPlaza Newark, that the desired CFM is not compromised, which allows the fan to perform as rated. , NJ NJ 07102 � . us.panasonic.com/venffans ®e c& m 2017cient LEM. VF17564SS0917 Panasonic Specification Submittal Data / Panasonic Ventilation Fan Description Ventilating fan shall be Low Noise ceiling mount type rated for continuous run. Fan shall be ENERGY STAR® rated and certified by the Home Ventilating Institute (HVI). Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: • Four —pole totally enclosed condenser motor rated for continuous run. • Power Rating shall be 120 volts and 60 Hz. • Fan shall be UL listed for tub/shower enclosure when used with a GFCI branch circuit wiring. • Motor equipped with thermal —cutoff fuse. • Removable with permanently lubricated plug—in motor. Housing: • Rust proof paint, galvanized steel body. • 6" diameter duct adaptor. • Built in backdraft damper. • Expandable extension bracket up to 26". EF-6 POLISHING ROOM Grille: • Attractive design using PP material. • Attaches directly to housing with torsion springs. Warranty: • ALL Parts: For period of 3 years from the date of the original purchase. Architectural Specifications: Ventilating fan shall be of the ceiling mount, Energy conserving vent type, with no less than 290 CFM and no more than 2.0 sones as certified by the Home Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge (w.g.) and with no less than 257 CFM as certified by HVI at 0.25 w.g. Power Consumption shall be no greater than 64 watts at 0.1 w.g. and 62 watts at 0.25 w.g. ENERGY STAR rated with efficiency of no less than 4.5 CFM/watt at 0.1 w.g. and 4.1 CFM/watt at 0.25 w.g. The motor shall be totally enclosed, four pole condenser type engineered to operate continuously. Power rating shall bell 20v/6OHz. Duct diameter shall be no less than 6". Fan shall be UL and cUL listed for tub/shower enclosure when used with GFCI branch circuit wiring. Fan shall be ASHRAE 62.2, LEED, ENERGY STAR IAP, EarthCraft, California Title-24, and WA Ventilation Code compliant. Specifications: WhisperCeiling FV-30VQ3 6" Duct Static Pressure in inches w.g. 0.1 0.25 Air Volume (CFM) 290 257 Noise (sones) 2.0 N/A Power Consumption (watts) 64 62 Energy Efficiency (CFM/Watt) 4.6 4.1 Speed (RPM) 877 990 Current (amps) 0.53 0.52 ENERGY STAR rated YES Washington State VIAQ Code YES As of date 4/11 For complete Installation Instructions visit www.panasonic.com/building FV-30VQ3 6" duct �s aFri �Y�16 FV-30VQ3 m 1.00 3 L V C w 0.80 v FV-30VQ3 0.60 ----20 Feet �, ------40 Feet — -60 Feet 0.40 ---80 Feet -------100 Feet 0.20 0.00 0 50 100 150 200 250 300 350 Airflow(CFM) Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: Panasonic Home and Environment Company Division of Panasonic Corporation of North America One Panasonic Way Secaucus, NJ 07094 www.panasonic.com/building �.- r1 HVI C uL us CERTIFIED ENEXG95 VF11076SS-30 Panasonic ideas for life fantech R a systemair company FG 12XL EC Centrif. Inline Fan 12" inline duct fan w/metal housing, EC motor, 120V, 1 Item #: 49905 Variant: 120V 1- 60Hz ®■ C �L US M NVI High efficiency inline duct fan for ventilation systems in residential and commercial applications where infinite airflow controllability is required. Economical use of energy and ease of control help this fan match the demand of any job. • Airflow 755 cfm at 0.2" Ps • Built-in potentiometer • Optional control via external devices outputting 0-10V signal such as temperature, occupancy sensor, gas detection, humidity, etc. • BMS compatible • LEED credit qualifier for green or passive house projects • Input from temp or occupancy sensor via a 0-10V signal or dry contact • Excellent energy savings especially at partial load • High cfm/W ratio • Low ambient noise when speed -controlled • 5-year factory warranty • ENERGY STAR® listed The fan comes with a built-in 0-10V potentiometer that makes it easier to find the preferred working point without any additional wiring. EF-1 & 2: FUME HOOD EXHAUST FANS Typical applications for FG 12XL EC are supply or exhaust air duct systems in offices, day care facilities, schools, gymnasiums, manufacturing facilities where airflow adjusts to the actual demand based on a day/time schedule, occupancy, CO2 level, etc. FG 12XL EC can be used as a remote mounted exhaust fan for residential kitchens. The housing is manufactured from a two-piece stamped, galvanized construction. The two halves are joined using Fantech's unique folded seam closure, which gives the fan the first in class, airtight seal. The fan motors can operate in temperatures up to 140OF and the motor bearings are permanently sealed, self -lubricated for maintenance -free life. FG 12XL EC has built-in thermal overload protection with automatic reset needing no user intervention. With the motor in the airstream, the fan provides the constant dissipation of heat build-up even at partial load thus giving the fan best in class for longevity and reliability. For the same air volume, FG 12XL EC consumes considerably less energy than an AC fan of its size. The mounting bracket and hardware are included, and the fan is ENERGY STAROO listed and comes with 5-year factory warranty. Item name: FG 12XL EC Centrif. Inline Fan I Product link: https://shop.fantech.net/en-US/productPermalink?p=99711 I Item #: 49905 1 Variant: 120V 1 - 60Hz I Document type: Product card I Created on: 2023-03-22 1 Generated by: Fantech Online Catalogue I Language: English Pagel of 11 Technical parameters Nominal data Voltage (nominal) Frequency Phases Input power Input current Impeller speed Air flow Temperature of transported air Max temperature of transported air, when speed controlled Protection/Classification Enclosure class, motor Insulation class Certificate Dimensions and weights Duct dimension; Circular, inlet Duct dimension; Circular, outlet Weight Optional Duct connection type Motor type 120 V 60 Hz 1- 166 W 1.16 A 2,510 rpm max 807 cfm -13 to 140 IF 140 IF IP44 B AMCA Air, HVI, cULus, ENERGY STAROO 16 lb Circular EC Item name: FG 12XL EC Centrif. Inline Fan Product link: https://shop.fantech.net/en-US/productPermalink?p=99711 I Item #: 49905 1 Variant: 120V 1 - 60Hz I Document type: Product card I Created on: 2023-03-22 Generated by: Fantech Online Catalogue I Language: English Page 2 of 11 Performance Performance curve in. wg. 0 100 200 300 400 500 600 700 cfm Hydraulic data Required air flow Required static pressure Working air flow Working static pressure Air density Power Fan control - RPM Current Airflow efficiency Control voltage Supply voltage 0.075 Ib/ft3 Item name: FG 12XL EC Centrif. Inline Fan I Product link: https://shop.fantech.net/en-US/productPermalink?p=99711 I Item #: 49905 1 Variant: 120V 1- 60Hz I Document type: Product card I Created on: 2023-03-22 1 Generated by: Fantech Online Catalogue I Language: English Page 3 of 11 Performances - - I auic 0" 0.2" 0.4" 0.6" 0.8" 1.0" 1.5" 0.2" Model Ps Ps Ps Ps Ps Ps Ps Ps FG 4XL 180 166 152 135 117 97 49 EC FG 6M EC 363 330 302 271 239 206 113 FG 8 EC 428 390 353 314 275 239 121 FG 10 EC 513 460 413 363 325 283 160 23 FG 12XL 805 750 686 615 537 474 315 - EC Dimensions Model A C D E F 4XL EC 4 (102) 8 1/2 (216) 6 1/2 (165) 1 (25) 1 (25) 6M EC 6 (152) 13 1/8 (333) 7 (178) 1 (25) 1 (25) 8 EC 8 (203) 13 1/4 (337) 6 (152) 1 1/8 (29) 1 (25) 10 EC 10 (254) 13 1 /4 (337) 4 3/4 (121) 1 1 /8 (29) 1 (25) 12XL EC 12 (305) 16 (406) 6 11/16 (170) 1 1/2 (38) 1 (25) Dimensions are in inches (mm). Item name: FG 12XL EC Centrif. Inline Fan I Product link: https://shop.fantech.net/en-US/productPermalink?p=99711 I Item #: 49905 1 Variant: 120V 1- 60Hz I Document type: Product card I Created on: 2023-03-22 1 Generated by: Fantech Online Catalogue I Language: English Page 4 of 11 Item name: FG 12XL EC Centrif. Inline Fan Product link: https://shop.fantech.net/en-US/productPermalink?p=99711 I Item #: 49905 1 Variant: 120V 1 - 60Hz I Document type: Product card I Created on: 2023-03-22 Generated by: Fantech Online Catalogue I Language: English Page 5 of 11 Wiring For connection to building fttftextern al motor speed controller Without external motor speed controller management system HTF10 - F&Ent�- Aa.sw=h24oV-� 4 r Item name: FG 12XL EC Centrif. Inline Fan Product link: https://shop.fantech.net/en-US/productPermalink?p=99711 I Item #: 49905 1 Variant: 120V 1 - 60Hz I Document type: Product card I Created on: 2023-03-22 Generated by: Fantech Online Catalogue I Language: English Page 6 of 11 Accessories . FML 12 Metal Hood Supply Air (45150) . ADC 12 Shut-off Damper w Motor (44692) . FGR 12 Filter Cassette (44686) . IG 12 Inlet Guard (411128) . LD 12 Silencer (411287) Documents . 483358 FG EC Submittal Sheet EN.pdf . 490095 FG EC OIPM EN FIR ES.pdf CSI Specification GUIDE SPECIFICATION . RSK 12 Backdraft Damper (411117) . FC 12 Mounting Clamps (2 pcs) (411123) . FGR 12HV Filter Cassette (49896) . IR 12 Iris Damper (411239) . EC- 10V Speed control (498148) Specifier Notes: This guide specification is written in Construction Specifications Institute (CSI) 3-Part Format in accordance with The CSI Construction Specifications Practice Guide, MasterFormat, SectionFormat, and PageFormat. Specifier Notes: This Section must be carefully reviewed and edited by the Architect or Engineer to meet the requirements of the Project and local building code. Coordinate this Section with Division 01, other specification sections, and the Drawings. Delete all Specifier Notes after editing this Section. Section numbers and titles are based on MasterFormat 2014 Update. SECTION 23 34 00 HVAC FANS Specifier Notes: This Section covers Fantech FG EC Series circular inline duct fans with electronically commutated motors (ECM). Consult Fantech for assistance in editing this Section as required for the Project. Specifier Notes: Use of FG EC Series circular inline duct fans may contribute to LEED credits. PARTI.GENERAL 1.1 SECTION INCLUDES A. Circular inline duct fans with EC (electronically commutated) motors 1.2 RELATED REQUIREMENTS Specifier Notes: Edit the following list of related sections as required for the Project. Limit the list to sections with specific information that the reader might expect to find in this Section, but is specified elsewhere. A. Section 23 31 00 — HVAC Ducts and Casings. B. Section 26 05 00 — Common Work Results for Electrical. 1.3 REFERENCE STANDARDS Specifier Notes: List reference standards used elsewhere in this Section, complete with designations and titles. Delete reference standards from the following list not used in the edited Section. A. Air Movement and Control Association International (AMCA) (www.amca.org): 1. AMCA 211 — Certified Ratings Program - Product Rating Manual for Fan Air Performance. 2. HVI 916 — Listed and Tested Accordingly 1.4 PREINSTALLATION MEETINGS Specifier Notes: Edit the Preinstallation Meetings article as required for the Project. Delete article if not required. A. Convene preinstallation meeting [i week] [2 weeks] before start of Work of this Section. B. Require attendance of parties directly affecting Work of this Section, including Contractor, Architect, installer, and manufacturer's representative. C. Review the Following: 1. Materials 2. Installation 3. Adjusting 4. Protection 5. Coordination with other Work 1.5 SUBMITTALS Specifier Notes: Edit the Submittals article as required for the Project. Delete submittals not required. A. Comply with Division 01. Item name: FG 12XL EC Centrif. Inline Fan I Product link: https://shop.fantech.net/en-US/productPermalink?p=99711 I Item #: 49905 1 Variant: 120V 1 - 60Hz I Document type: Product card I Created on: 2023-03-22 1 Generated by: Fantech Online Catalogue I Language: English Page 7 of 11 B. Product Data: Submit manufacturer's product data, including installation instructions. C. Shop Drawings: Submit manufacturer's shop drawings, including plans, elevations, sections, and details. 1. Wiring Diagrams: Indicate wiring for each item of equipment and interconnections between items of equipment. 2. Include manufacturer's names, model numbers, ratings, power requirements, equipment layout, device arrangement, complete wiring point-to-point diagrams, and conduit layouts. D. Manufacturer's Certification: Submit manufacturer's certification that materials comply with specified requirements and are suitable for intended application. E. Operation and Maintenance Data: 1. Submit manufacturer's operation and maintenance manual; including the following: a. Operation, maintenance, adjustment, and cleaning instructions. b. Troubleshooting guide c. Parts list d. Electrical wiring diagrams if required. 2. Provide detailed information required for Owner to properly operate and maintain equipment. F. Warranty Documentation: Submit manufacturer's standard warranty. 1.6 QUALITY ASSURANCE A. Manufacturer's Qualifications: Manufacturer regularly engaged in the manufacturing of circular inline duct fans to that specified for a minimum of 10 years. B. Installer's Qualifications: 1. Installer regularly engaged in installation of circular inline duct fans of similar type to that specified for a minimum of 5 years. 2. Use persons trained for installation of circular inline duct fans. 1.7 DELIVERY, STORAGE, AND HANDLING A. Delivery Requirements: Deliver materials to site in manufacturer's original, unopened containers and packaging, with labels clearly identifying product name and manufacturer. B. Storage and Handling Requirements: 1. Store and handle materials in accordance with manufacturer's instructions. 2. Keep materials in manufacturer's original, unopened containers and packaging until installation. 3. Store materials in clean, dry area indoors. 4. Keep materials from freezing. 5. Protect materials during storage, handling, and installation to prevent damage. 1.8 WARRANTY Warranty Period: 5 years PART 2. PRODUCTS 2.1 MANUFACTURERS A. Manufacturer: Fantech Inc., 10048 Industrial Blvd., Lenexa, Kansas 66215. Phone 800-747-6217. www.fantech.net. ussupport@fantech.net. Specifier Notes: Specify if substitutions will be permitted. B. Substitutions: [Not permitted] [Comply with Division 01]. C. Single Source: Provide materials from single manufacturer. 2.2 HVAC FANS A. Circular inline Duct Fans with Electronically Commutated Motors (ECM): FG EC Series 1. Rating: AMCA 211 2. Compliance AMCA Certified Rating Programs 3. AMCA Air Seal 4. cULus Listed 5. ENERGY STAR® Rated 6. HVI 916 Specifier Notes: Specify circular inline duct fan models as required for the Project. Delete models not required. B. Model: "FG 4XL EC" 1. Inlet Diameter: 4 inches 2. Outlet Diameter: 4 inches 3. Casing Diameter: 8-1/2 inches 4. Inlet and Outlet Connection Collars: 1 inch 5. Casing Material: Galvanized Metal with air -tight, folded seam construction. A housing seam joined with screws or rivets is unacceptable. 6. Motor: External -rotor ECM 7. Speed Control: Built-in potentiometer 0-10V 8. Motor Protection: electronically protected 9. Blades: Backward curved 10. Voltage: 120 V 11. Frequency: 50/60 Hz Item name: FG 12XL EC Centrif. Inline Fan Product link: https://shop.fantech.net/en-US/productPermalink?p=99711 I Item #: 49905 1 Variant: 120V 11- 60Hz I Document type: Product card I Created on: 2023-03-22 Generated by: Fantech Online Catalogue I Language: English Page 8 of 11 12. Nominal Voltage Range: 100 to 130 V 13. Phase: 1 14. Maximum Airflow: 180 cfm 15. RPM: 4,038 16. Power Rating, Motor: 33 W 17. Current: 0.48 A 18. Operational Temperature: minus 13 to 140 degrees F 19. Weight: 4.6lbs 20. Motor Insulation Class: B 21. Motor Enclosure Class: IP44 C. Model: "FG 6M EC" 1. Inlet Diameter: 6 inches 2. Outlet Diameter: 6 inches 3. Casing Diameter: 13 1/8 inches 4. Inlet and Outlet Connection Collars: 1 inch 5. Casing Material: Galvanized Metal with air -tight, folded seam construction. A housing seam joined with screws or rivets is unacceptable. 6. Motor: External -rotor ECM 7. Speed Control: Built-in potentiometer 0-10V 8. Motor Protection: electronically protected 9. Blades: Backward curved 10. Voltage: 120 V 11. Frequency: 50/60 Hz 12. Nominal Voltage Range: 100 to 130 V 13. Phase: 1 14. Maximum Airflow: 364 cfm 15. RPM: 2,491 16. Power Rating, Motor: 74 W 17. Current: 1.0 A 18. Operational Temperature: minus 13 to 140 degrees F 19. Weight: 9 Ibs 20. Motor Insulation Class: B 21. Motor Enclosure Class: IP44 D. Model: "FG 8 EC" 1. Inlet Diameter: 8 inches 2. Outlet Diameter: 8 inches 3. Casing Diameter: 13 1/4 inches 4. Inlet and Outlet Connection Collars: 1 inch 5. Casing Material: Galvanized Metal with air -tight, folded seam construction. A housing seam joined with screws or rivets is unacceptable. 6. Motor: External -rotor ECM 7. Speed Control: Built-in potentiometer 0-10V 8. Motor Protection: electronically protected 9. Blades: Backward curved 10. Voltage: 120 V 11. Frequency: 50/60 Hz 12. Nominal Voltage Range: 100 to 130 V 13. Phase: 1 14. Maximum Airflow: 428 cfm 15. RPM: 2,515 16. Power Rating, Motor: 71 W 17. Current: 0.5 A 18. Operational Temperature: minus 13 to 140 degrees F 19. Weight: 8.4lbs 20. Motor Insulation Class: B 21. Motor Enclosure Class: IP44 E. Model: "FG 10 EC" 1. Inlet Diameter: 10 inches 2. Outlet Diameter: 10 inches Item name: FG 12XL EC Centrif. Inline Fan Product link: https://shop.fantech.net/en-US/productPermalink?p=99711 I Item #: 49905 1 Variant: 120V 1- 60Hz I Document type: Product card I Created on: 2023-03-22 Generated by: Fantech Online Catalogue I Language: English Page 9 of 11 3. Casing Diameter: 13 1/4 inches 4. Inlet and Outlet Connection Collars: 1 inch 5. Casing Material: Galvanized Metal with air -tight, folded seam construction. A housing seam joined with screws or rivets is unacceptable 6. Motor: External -rotor ECM 7. Speed Control: Built-in potentiometer 0-10V 8. Motor Protection: electronically protected 9. Blades: Backward curved 10. Voltage: 120 V 11. Frequency: 50/60 Hz 12. Nominal Voltage Range: 100 to 130 V 13. Phase: 1 14. Maximum Airflow: 511 cfm 15. RPM: 2,311 16. Power Rating, Motor: 93 W 17. Current: 0.65 A 18. Operational Temperature: minus 13 to 140 degrees F 19. Weight: 9.2lbs 20. Motor Insulation Class: B 21. Motor Enclosure Class: IP44 F. Model: "FG 12XL EC 1. Inlet Diameter: 12 inches 2. Outlet Diameter: 12 inches 3. Casing Diameter: 16 inches 4. Inlet and Outlet Connection Collars: 1 inch 5. Casing Material: Galvanized Metal with air -tight, folded seam construction. A housing seam joined with screws or rivets is unacceptable. 6. Motor: External -rotor ECM 7. Speed Control: Built-in potentiometer 0-10V 8. Motor Protection: electronically protected 9. Blades: Backward curved 10. Voltage: 120 V 11. Frequency: 50/60 Hz 12. Nominal Voltage Range: 100 to 130 V 13. Phase: 1 14. Maximum Airflow: 807 cfm 15. RPM: 2,510 16. Power Rating, Motor: 166 W 17. Current: 1.16 A 18. Operational Temperature: minus 13 to 140 degrees F 19. Weight: 16 Ibs 20. Motor Insulation Class: B 21. Motor Enclosure Class: IP44 2.3 ACCESSORIES A. Silencers for Circular Ducts Specifier Notes: Delete accessories not required. 1. Model: ["LD 4"] ["LD 6"] ["LD 8"] ["LD 10"] ["LD 12"] 2. Insulation Thickness: 2 inches. B. Mounting Clamps for Circular Ducts Specifier Notes: Delete accessories not required. 1. Model: ["FC 4"] ["FC 6"] ["FC 8"] ["FC 10"] ["FC 12"] 2. Material: Galvanized sheet metal with 1/3 inch neoprene lining 3. Width: 2-1/3 inches 4. Clamps Together: 2 screws 5. Quantity: 2 pcs per kit C. External Remotely Mounted Potentiometer Specifier Notes: Delete if not required. 1. Model: MTP10 2. Remotely mounted manual -speed control for air flow adjustments and balancing. Item name: FG 12XL EC Centrif. Inline Fan Product link: https://shop.fantech.net/en-US/productPermalink?p=99711 I Item #: 49905 1 Variant: 120V 1- 60Hz I Document type: Product card I Created on: 2023-03-22 Generated by: Fantech Online Catalogue I Language: English Page 10 of 11 3. Voltage: 0 to 10V DC 4. Enclosure class: IP54 D. Demand controller for pressure and constant flow ventilation Specifier Notes: Delete if not required. 1. Model: PCA1000 D2 2. The sensor control module for differential pressure and volume flow measures and indicates the pressure or, optionally, the volume flow in a ventilation system. The calculation of the volume flow is performed by entering the K-factor of the application. 3. Output Signal: 0 to 10V DC 4. Adjustable measuring range: 0 to 4 in.wg. 5. Enclosure class: IP54 PART 3. EXECUTION 3.1 EXAMINATION A. Examine areas to receive circular inline duct fans. B. Notify Architect of conditions that would adversely affect installation or subsequent use. C. Do not begin installation until unacceptable conditions are corrected. 3.2 INSTALLATION A. Install circular inline duct fans in accordance with manufacturer's instructions at locations indicated on the drawings. B. Attach duct work to inlet and outlet connection collars of circular inline duct fans in accordance with manufacturer's instructions. C. Electrical: Install electrical power to circular inline duct fans as specified in Section 26 05 00. 3.3 ADJUSTING A. Adjust circular inline duct fans for proper operation in accordance with manufacturer's instructions. 3.4 PROTECTION A. Protect installed circular inline duct fans from damage during construction. END OF SECTION Item name: FG 12XL EC Centrif. Inline Fan Product link: https://shop.fantech.net/en-US/productPermalink?p=99711 I Item #: 49905 1 Variant: 120V 1- 60Hz I Document type: Product card I Created on: 2023-03-22 Generated by: Fantech Online Catalogue I Language: English Page 11 of 11 Project: Cline Submittal Date: 3/22/2023 C&S AIR PRODUCTS Submitted By: mikej Submittal BACK -DRAFT DAMPERS & ACTUATORS Model AC-25R FOR EF-1 & 2 + SF-1 & 2 Round control damper, single blade General construction Dimensions: Nominal (approximately 1/8" (3) undersize) Material: Galvanized steel Frame: 12" x 20 gauge Blade style: 14 gauge equivalent, round Blade action: Single blade Axles: 1/2" (13) diameter plated steel Linkage: Concealed in frame Bearings: Synthetic Sleeve: Type: Sleeve; Length: 12"; Gauge: 20"; Clearance: Centered Control shaft: 1/2" x 3" (13 x 76) drive axle Seals: Polyethylene blade edge seals Options Actuator: 2-position spring return Ratings Maximum leakage: 5.5 cfm/ft2 @ 10 in. wg (0.028m'/s/ m2 @ 2.5 kPa) 5.0 cfm/ft2 @ 8 in. wg (0.026m'/s/ m2 @ 2.0 kPa) 3.3 cfm/ft2 @ 4 in. wg (0.017m'/s/ m2 @ 1.0 kPa) 1.5 cfm/ft2 @ 1 in. wg (0.008m'/s/ m2 @ 0.25 kPa) Operating temperature range: -25OF to 180OF Details Model AC-25R with sleeve Side view Dimensions (in.xxxx) Ratings Actuator Line Press Power Transformer item Tag Qty D Vel (fpm) (in.w.g.) Qty Model Volt Pos Orien Loc consumption sizing (VA) 1 2 10 4000 10 1 TFB120-S 120V PO Perp Ext 2.5W 5 This submittal sheet reflects only the construction and options selected and is not indicative of all constructions and options that are available for the product. For more information, please contact your local representative or visit us at www.csairproducts.com. Information is subject to change without notice or obligation. Note: Dimensions in parentheses ( ) are millimeters. C&S AIR PRODUCTS 5101 Blue Mound Rd, Fort Worth TX 76106 Page 1 of 2 Project: Cline Submittal Date: 3/22/2023 C&S AIR PRODUCTS Submitted By: mikej Submittal Model AC-25R Performance 6 d 3 1 a 12 18 24 Damper Diameter (inches) Pressure limitations o� 6 12 18 2E Damper Diameter (inches) Velocity limitations a01i N.�. I I . . -i 100 1,000 10,000 VNxity ftnn) 6D 6D Ducted inlet and outlet AMCA Figure 5.3 Illustrates a fully ducted damper. This configuration represents the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Pressure drop testing Pressure drop testing was performed in accordance with AMCA Standard 500-D. All data has been corrected to represent air density of 0.075 lb/ft. Actual pressure drop in any ducted HVAC system is a combination of many elements. This information, along with analysis of other system influences, should be used to estimate actual pressure losses for a damper installed in a given HVAC system. This submittal sheet reflects only the construction and options selected and is not indicative of all constructions and options that are available for the product. For more information, please contact your local representative or visit us at www.csairproducts.com. Information is subject to change without notice or obligation. Note: Dimensions in parentheses () are millimeters. C&S AIR PRODUCTS 5101 Blue Mound Rd, Fort Worth TX 76106 Page 2 of 2 TFB120(-S), TFX120(-S) On/Off, Spring Return,100 to 240 VAG // BELIMOF Torque min. 22 in-lbs, for control of air dampers Application For on/off, fail-safe control of dampers in WAC systems. Actuator sizing should be done in accordance with the damper manufacturer's specifications. Control is on/off from an auxiliary contact, or a manual switch. The actuator is mounted directly to a damper shaft from 114' up to 112" in diameter by means of its universal clamp, 1 /2" shaft centered at delivery. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. Operation The TF series actuators provide true spring return operation for reliable fail-safe e application and positive close off on air tight dampers. The spring return system provides consistent torque to the damper with, and without, power applied to the actuator: carEP wos Y1- us �Err.ino.s g NEC.EWIP. Technical Data Power supply nominal tolerance TFB 120 1 100 to 240 VAG, 50160 Hz 85 to 265 VAC, 50160 Hz Power consumption running holding 2.5 W 1.3 W Transformer sizing 5 VA class 2 power source Electrical connection TFB120... 3 ft,18 GA appliance cable, 112" conduit connector -5 models: two 3 ft, 18 gauge appliance cables with 112" conduit connectors TFX120... 3 ft [1m],10 It [3m], or 16 ft [5m], 18 GA appliance cable, with or without 112' conduit connector -S models: two 3 ft [1 m], 10 ft [3m] or 16 It [5m] appliance cables with or without 112" conduit connectors Overload protection electronic throughout 0 to 95° rotation Electrical protection actuators are double insulated Angle of rotation max 950, adjust. with mechanical stop Torque 22 in-lbs 2.5 Nm minimum Direction of rotation reversible with cwlccw mounting Position indication visual indicator, 0° to 95° (0° spring returnposition) Running time motor spring < 75 sec ¢ 25 sec ®40F to 122°F [-200C to 500C] 60 sec @-220F -300 Humidity 5 to 95% RH non -condensing Ambient temperature -220F to 1220E -30°C to 50°C Storage temperature -40°F to 176°F -40'C to 80°C Housing NEMA type 211P42, UL enclosure type 2 Housing material UL94-5VA Agency listingst cULus acc. to UL60730-1 W-2-14 , CANICSA E60730-1:02, CE acc. to 200411 081EC (and 20061951EC for -S versions Noise level (max) running spring return < 50 db fit dB A Servicing maintenance free Quality standard ISO 9001 Weight 1.4 Ibs 0.6 kg), 1.5 Ibs 0.7 k with switch t Rated Impulse Nonage OV, Type of action IAA (1 AA.B for -5 version), Control Pollution Degree 3, TF612D-S,TFX120-S Auxiliary switch 1 x SPDT 3A (0.5A) @ 250 VAC, UL approved adiustable 0' to 95° The TF series provides 95° of rotation and is provided with a graduated position indicator showing 00 to 900. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. Power consumption is reduced in holding mode. The actuator is double insulated so an electrical ground connection is not necessary. The TF-S versions are provided with one built-in auxiliary switch. This SPOT switch is provided for safety interfacing or signaling, for example, for fan start-up. The switching function is adjustable between O° and 950. SAFETY NOTE Screw a conduit fitting into the actuator's bushing. Jacket the actuator's input and output wiring with suitable flexible conduit. Properly terminate the conduit in a suitable junction box. Dimensions Inches mm �ig to standard- '' F119-51 0[111 ® [I.yI7 // BELT MCY TFB120(-S), TFX120(-S) On/Off, Spring Return,100 to 240 VAG Accessories TDol-06 8mm and 10 mm wrench KH-TF Crank arm for up to 112" round shaft IG-TF2 Crank arm adaptor kit forTF 2G-TF112 Mounting bracket, kit forTF IS-100 Weather shield metal 2S-150 Weather shleId of carbonate NOTE, When using TF81 A-S) and TFx1201-S7 acluators, only use accessories listed on this page - For actuator wiring information and diagrams, refer to eelimo wiring guide. OnlOff spring return damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a shaft up to a 112" diameter and center a 112" shaft- The actuators must be designed so that they may be used for either clockwise or counterclockwise fail-safe operation. Actuators shall be protected from overload at all angles of rotation. If required, one SPOT auxiliary switch shall be provided having the capability of being adjustable. Actuators must be constructed to meet the requirements for Double Insulation so an electrical ground is not required to meet agency listings. Actuators shall be cULus listed and have a 5 year warranty, and be manufactured under ISO 9001 International Duality Control Standards. Actuators shall be as manufactured by Belimo- X INSTALLATION NOTES Al Provide overload protection and disconnect as required. 0 CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption must be observed. For end position indication, interlock control, fan startup, etc., TFB120-S, TFx120-S incorporate one built-in auxiliary switch: 1 x SPOT, 3A (0.5A) 0250 VAC, UL Approved, adjustable 0° to 95'. APPLICATION NOTES Meets cULus requirements without the need of an electrical ground connection. QWARNING bye Electrical Componentsl During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been pmpedy trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical compo- nents Gould result in death or serious injury. 100 to 240 VAC N L1 1 1 Neutral H L2 �-�� 2 Hot A On/Off wiring for TF13120, TFX120 I 51 A y I S2 NC I 53 0 0'to 95' On/Off wiring for TFB120-S, TFX120-S 0 168 1 1 E WMW - � T 10" S-Prime Evo EC 1147707 3.28 -- i 0. 2.87 2.45 - kh6ok 2.05 8V i 1,64 7V 1.23 6V 0.82 5V 14V 0.41 j 3V 2V u 0 2 70% r)max EK= qV 505 cfm Psf 0.76 in.wg Pf 0. B2 Pa U 120 V f 60 Hz lA Plc W P1 77 W n 2341 Urnin SFP 325 W1(rnVs) rlFa 54 ec rit 56 UT 6 V technology • ®®®®®®®®® M®EMMO® MEMEXIM ®N • N ®NMNM DEN • NON N®®N® MNZN • NM®N®N®ME 29.5 59C 885 1180 1475 qV [cfm] Operating Point 777 777 10" S-Prime Evo EC 1147707 Voltage UN 120 V 1- Current I A 2,9 2,6 3,4 3,5 3,3 Current Imax 3,5 A Power consumption P1 W 255 225 313 314 298 Ambient temperature to 40 °C Rotation speed n 1 /min 3840 3895 3766 3763 3865 Conveyed medium temperature tM 40 °C SWL inlet LWA5 dB(A) 78 77 76 75 77 Speed Control 0-10V SWL outlet LVVA6 dB(A) 75 75 75 75 77 Motor protection TEC SWL housing break out LWA2 dB(A) 64 64 63 64 64 Insulation class motor F Sound power (LW) dB(A) Medium Frequency Band Weight 10,5 kg E 63 125 250 500 1k 2k 4k 8k Number of poles Inlet LVVA5 66 39 56 62 58 57 54 52 42 IP motor IP30 Outlet LWA6 66 31 47 63 61 57 48 48 37 IP terminal box IP44 Housing LVVA2 57 31 33 42 54 51 40 34 21 IP complete unit IPX4 radiation Min. operating temperature -30 °C ®®® MEMM MMMM®MMMNMRM®O®®®®®O®®®®®®®® DEEM= M®®®®®®®®®®M EM M MM®M®MM®MMMKMMM®OEM ®®® MEMO MMMMM ® M M ®®® MEMM MMMMM CM N O N M O N N C �L d 1 1 8" S-Prime Evo EC 1147671 qv 746 cfm PIf 0.00 in.wg Pf 0.30 Pa 118 236 354 472 590 708 fin MVS) 826 qV [cfm] Operating Point V P P 9 Q Current I A 1,3 1,2 1,5 1,5 1,5 Power consumption P1 W 103 97 125 125 123 Rotation speed n 1 /min 3145 3149 3018 2927 2982 SWL inlet LWA5 dB(A) 69 67 71 70 71 SWL outlet LVVA6 dB(A) 69 68 72 72 74 SWL casing break out LVVA2 dB(A) 56 55 56 56 57 Sound power (LW) dB(A) Medium Frequency Band E 63 125 250 500 1k 2k 4k 8k Inlet LWA5 71 46 52 65 65 64 61 61 55 Outlet LWA6 74 46 53 70 70 64 55 52 43 Housing LVVA2 57 44 40 52 51 51 47 42 29 radiation • IXII�IIxJlxJlxJl71�11�IJI�IL�JI�IL�J�SI�IIXIVI�SIIIIxJIi9�IlxJ�IL�RSII�II� • ®®®®®®®®® MEMO®®® 3EMEEN MEN • M EMMMM MMEN • MOE MIKE®NE MMZM • MMMOMMOM®MMM�M®®M 8" S-Prime Evo EC 147671 Voltage UN 120 V 1- Current Imax 1,6 A Ambient temperature to 40 °C Medium temperatures tM 40 °C Speed Control 0-10V Motor protection TEC Insulation class motor F Weight 9,2 kg Number of poles IP motor IP54 IP terminal box IP44 IP complete unit IPX4 Min. operating temperature -30 °C ®®® MEMM MMMM®MM®MEM®M®MEMMM®MMMEM®M M@MMM®MM3EMMMMMMM®®MOM MM®MEMMEMMMKMMM®EEM ®®® MEMO MMMMM ® M M ®®® MEMM MMMMM N O N O C �L d je DH-I & 2: MAKE-UP AIR DUCT HEATERS • New expanded range • Capacities from 1 to 12 KW • Fits from 5" to 12" diameter ducts - - • Built-in adjustable electronic duct sensor (adjustable from 0°C to 42°C / 32°F to 108°F ) • Equipped with the most advanced Electronic Modulating Controller and Patented Air Flow Sensor • Remote thermostat option available (THERMO-ZONE model) • Just one electrical connection and the unit is ready to perform Today's airtight homes and offices beg for fresh air. When we trap the heat, excess humidity and indoor pollutants such as cleaning products, smoking and pets, will negatively affect the quality of the air we breathe, making our environment both uncomfortable and unhealthy. Stale and humid air has to be replaced by fresh air. During winter, the incoming fresh air is at too low a temperature to be comfortable and requires preheating. It is more economical to preheat the incoming air at a specific, controlled source than requiring the central system to continually compensate for heat loss. The THERMO-AIR heater is designed to complement your heating system by preheating this fresh air at the lowest cost, thus continuously providing comfortable ventilation throughout the house. Equipped with the most advanced modulating controller and air sensor, the THERMO-AIR heater will operate with extremely low air flow (see specifications). The unit uses the minimum amount of energy required to meet your needs. The air flow sensor detects the amount of air flowing through the unit and modulates the heating capacity accordingly, maximizing savings. The THERMO-AIR heater is a quality product engineered for peak performance and long life. - -------Z-------- y y THERMOmAIR, FEATURES AND SPECIFICATIONS Automatic Reset Thermal Cut-out Safety feature preventing overheating; will reset automatically after cool -off. Air Flow Sensor Modulates the heating capacity according to the quantity of air flowing through the heater. Open Coil Elements Made of the highest grade nickel -chrome resistance wire, they will not age or oxidize, thus assuring longer heater life. Temperature Sensor Controls the heater proportionally to maintain the pre-set air temperature in the duct. Enclosure Corrosion resistant galvanized steel. Built-in Electronic Temperature Controller and Sensor Proportionally modulates the heating load to match the exact capacity required, thus mini ' operating cost. DH-1: 240/1/60 Manual Reset Thermal Cut-out 7 KW Additional safety feature which prevents the frame from overheating. 29.2 AMPS Round Collars MODEL# Simplifies the installation and considerably reduces field labor. TER- 10-7-240V Terminal Block Only one electrical connection required through an easily accessible power terminal block. AVAILABLE STOCK MODELS: frame 5" or 6" 1 240V/4.2A or 208V/4.8A or 120V/8.3A 30 sizes available)DIMENSIONS (3 5" or 6" 2 240V/8.3A or 208V/9.6A or 120V/16.7A 60 A 11.5" 8.0" 11.5" 8" 3 240V/12.5A or 208V/14AA 90 B 11.5" 10.0" 13.5" 8" 4 240V/16.7A or 208V/19.2A 120 81, 5 240V/20.8A or 208V/24.OA 150 C 15.5" 12.0" 15.5" 8" 6 240V/25.OA 180 10" 3 240V/12.5A or 208V/14AA 90 10" 4 240V/16.7A or 208V/19.2A 120 To specify the model required, follow 10„ 5 240V/20.8A or 208V/24.OA DH-2: 150 the example below: 240/1/60 10" 6 240V/25.OA 180 TER-6-2-240 12" 6 240V/25.OA 5 KW 180 � I L- 10" or 12" 8 240V/A 20.8 AMPS 0 COLLAR SIZE VOLTAGE 10" or 12" 10 240V/41..6A MODEL# 300 KILOWATTS 10" or 12" 12 240V/47.9A (11.5KW) TER-8-5-240V 345 Specifications are for standard units. For other sizes, voltages and capacities, please contact your Thermolec representative. TYPICAL APPLICATIONS OF THE THERMO AIR HEATER HEAT PUMP .• i I W FRESH AIR, I /, HEATER HEAT Heat RECOVERY UNIT Recovery WALL CAP Ventilation & Heat Pump DISCHARGE : •• FURNACE GRILLE _ RETURN AIR =__= FAN DUCT '. FRESH AIR HEATER FRESH AIR HEATER INSULATION INSULATION _-= WALL CAP WALL CAP central Air Hydronic or Furnace Baseboard Heating THMOLEC TEL.:5Web3www hermolec.com6-3270 \A® CV 1-us V2.2 fantech° a systemair company FGR 10HV Filter Cassette with pleated MERV10 filter Item #: 98005 The filter cassette for supply air features a disposable pleated MERV10 filter, galvanized sheet steel housing and toggle locks. The filters will collect mold spores, pollen, cement dust, carpet fibers, debris, lint, and insects in the supply air. With normal usage, it is recommended that you replace the filter every 3-5 months. For replacements, use FGR HV Replacement filter. Technical parameters Filter FB-1 & 2: SF 1-2 FILTER HOUSINGS Filter class MERV10 Dimensions and weights Duct dimension; Circular, inlet 10 in. Weight 35 lb Optional Duct connection type Circular Item name: FGR 10HV Filter Cassette I Product link: https://shop.fantech.net/en-US/productPermalink?p=145575 I Item #: 98005 I Document type: Product card Created on: 2023-03-22 1 Generated by: Fantech Online Catalogue I Language: English Pagel of 3 Dimensions 1 O 4 04 O 4 6 D Model A B C D FGR 8HV 29 1/4 (743) 7 7/8 (200) 20 (508) 19 7/8 (505) FGR 10HV 29 1/4 (743) 9 7/8 (251) 20 (508) 19 7/8 (505) FGR 12HV 29 1/4 (743) 11 7/8 (302) 20 (508) 19 7/8 (505) FGR 14HV 29 1/4 (743) 13 7/8 (352) 20 (508) 19 7/8 (505) All dimensions are in inches (mm) Item name: FGR 10HV Filter Cassette l Product link: https://shop.fantech.net/en-US/productPermalink?p=145575 I Item #: 98005 1 Document type: Product card Created on: 2023-03-22 1 Generated by: Fantech Online Catalogue I Language: English Page 2 of 3 Accessories . FGR HV Filter Pack (56062) Item name: FGR 10HV Filter Cassette I Product link: https://shop.fantech.net/en-US/productPermalink?p=145575 I Item #: 98005 1 Document type: Product card Created on: 2023-03-22 1 Generated by: Fantech Online Catalogue I Language: English Page 3 of 3