APPROVED BLD-RESUB 1-BLD2023-0196+Plans+4.4.2023_8.53.20_AM+3461332APPROVED BY PLANNING
Apr 05 2023
O
O
Z
ISEPERATE REMODEL PERMIT ISSUED FOR
ITHIS PROJECT I
!PERMIT NUMBER: BLD2023-0158
I
I------------------------------ —_I
RS=�1 i%
- .N: Y
Zone ----- . Corner ______Flag
Setbacks: Required Actual
Front
Sides 10'ex.
Rear
Other
Height
25' ex.
0
N8902413611W (160.001)
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
City Of Edmonds
Building Department
Work MECHANICAL FOR REMODEL
Address 18810 92ND AVE W
................................................................................................
..................................................................................................................
Owner 18810 92ND AVE W
.................................
....................................
Approved Date: 4/5/2023
........................ .............................................................
Building Official � /reIP//( 91000rdl�lal
Permit Number BLD2023-0196
APPROVED
PLANS MUST BE
ON JOB SITE
' N890 241 3611W
INTERIOR RENOVATION ONLY. All renovations are
non-structural. No change to building footprint, roofline,
square footage, lot coverage, or hardscapes, or
height limit.
O
COLEI"IAN 2-TON NEAT PUMP
MODEL# I-IMH1252415
O
NIT,4GNI 3-TON MINI VRF HEAT PUMP
MODAL# CvANP03/oB215
(25.001)
N85056139"W
u
i
(175.00')
5 I TE f=L N �1 D
3.22.23
RESUB
Apr 04 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
0
00
18810 92nd Ave W - Edmonds, WA
NoFT�4
WALLS TO BE REMOVED ARE NON -BEARING;,
OALL
NON-STRUCTURAL, NON -SHEAR WALL.
CABINETRY AND/OR FIXTURES
OEXISTING
TO BE REMOVED
EXIST. 11,41N FLOOD $ [)E110 FLAN
SCALE: 1/4" = V - 0"
OEXIST.
30"x22" ATTIC ACCESS
OEQUIPMENT
IN ATTIC SPACE SHALL HAVE A LEVEL
WORIGINGx SPACE NOT LESS THAN 30"x3O" IN FRONT
ATTIC
OF THE CONTROL SIDE OF THE APPLIANCE IN
EQUIP.
ACCORDANCE WITH 2O18 IRC M1305.1.2.
MINIMUM 30" HIGH x 22" WIDE PASSAGE WAY MUST
BE PROVIDED TO EQUIPMENT. PASSAGE WAY SHALL
NOT BE LONGER THAN 20 FT. PER 2018 M1305.12.
A LIGHT CONTROLLED SWITCH SHALL BE LOCATED
AT ATTIC PASSAGEWAY OPENING AND A RECEPTACLE
OUTLET SHALL BE INSTALLED AT/NEAR THE
EQUIPMENT LOCATION PER 2018 M1305.1.2.1.
LAUNDRY CLOSET PROVIDE 100 SQUARE INCH
OAT
OPENING (MIN.) PER 2018 IRC 504b.
ALL WINDOWS ARE EXIST.
ALL DOORS ARE EXIST. U.N.O.
THERE IS NO CHANGE TO THE PERMITER/FOOTPRINT
OF THE HOME, NOR IS THERE ANY CHANGE TO EXIST
LOT COVERAGE, GROSS FLOOR AREA, IMPERVIOUS
SURFACE, HEIGHT OR SETBACK LIMITATIONS.
CM
INDICATES HARD WIRED AND INTERCONNECTED SMOKE
d CARBON MONOXIDE DETECTOR WITH BATTERY
110V
BACKUP. IN ACCORDANCE WITH 2O18 IRC R314 AND
R315.
FFR0F06E D �1,4I I V FL ®®FR FLAN
SCALE: 1/4" = V - 0"
3.15.23
RESUB
Apr 04 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
L
O
W
2
WALLS TO BE REMOVED ARE NON -BEARING,
OALL
NON-STRUCTURAL, NON -SHEAR WALL.
CABINETRY AND/OR FIXTURES
OEXISTING
TO BE REMOVED
EXIST. LOUJ FL00 4 D 110 FLAN
SCALE. 1/4" = 1' - 0"
ELECTRIC AIR HANDLER. NO COMBUSTION AIR
ONEW
REQUIRED.
ALL WINDOWS ARE EXIST. UN.O.
ALL DOORS ARE EXIST. U.N.O.
THERE IS NO CHANGE TO THE PERMITER/FOOTPRINT
OF THE HOME, NOR IS THERE ANY CHANGE TO EXIST
LOT COVERAGE, GROSS FLOOR AREA, IMPERVIOUS
SUWACE, HEIGHT OR SETBACK LIMITATIONS.
CM
INDICATES HARD WIRED AND INTERCONNECTED SMOKE
d CARBON MONOXIDE DETECTOR WITH BATTERY
110v
BACKUP. IN ACCORDANCE WITH 2O10 IRC R314 AND
R315.
FFR0F06ED LOUJ FL00 FLAN
SCALE. 1/4" = 1' - 0"
J. 1 J.LJ
RESUB
Apr 04 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
3