Loading...
REVIEWED-BLD2023-0196-Specifications mini-vrf outdoor unit (1)(Y, H) VAHP0361321S 36,000 Btu/h Mini VRF Outdoor Unit Job Name: Location: Purchaser: Order No: Engineer: Submitted To: Approval: Construction: Submitted By: Date: Unit Designation: Schedule No: Model No: ....,.,.,.,................................ REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT: FEATURES • Cooling up to 1187 and heating down To -4°F. • One outdoor unit for up to 8 indoor units • Ideal choice for building with zero lot Lines or zoning restrictions • Flexible — Numerous systems configurations multiple -sized outdoor units and multiple options of indoor unit types and capacities • Adaptable — Up to 984 ft. total pipe length • Versatile — Up to 164ft. vertical distance between outdoor unit and indoor units • Quiet operations — as low as 48 dB(A) sound level for outdoor units and 28 dB(A) for indoor units Model (Y,H)VAH P036B21 S Power Supply 208/23OW 1 PH 60Hz Capacity (Nominal) *1 Cooling Capacity (Nominal) Btu/h I (kW) 36,000 1 (10.6) Power input kW 2.53 Current input A(208V/23OV) 12.3 /11.1 ------ Heating -------------- Capacity (Nominal) Btu/h I (kW) 40,000 1 (11.7) Power input kW 2.36 Current input A(208V/230V) 11.8 / 10.6 Efficiency Ratings*1 (Non -Ducted / Ducted) Cooling Rated Capacity Btu/h 36,000 /36,000 ------- EER Btu/Wh ----- 16.70 / 13.70 SEER Btu/Wh 23.10 / 18.70 Heating Rated Capacity Btu/h 40,000 /40,000 COP W/W 1 5.12 / 3.90 HSPF Btu/Wh 11.90 / 11.00 Cooling Operating Range *2 Indoor OF WB (°C WB) 59 (15) - 73 (23) Outdoor ------ OF DB (cC DB) 23 (-5) - 118 (48) Heating Operating Range *2 Indoor of DB (cC DB) 59 (15) - 80 (27) Outdoor of WB (oC WB) -4 (-20) - 59 (15) Cabinet Color(Munsell Code) - 1.OY8.5/0.5 Outer Dimensions Package Dimensions Height in (mm) 1 54-5/16 (1380) Width Depth Height in in ----- in (mm) () -mm------- (mm) 37-3/8 14-9116 ------------ 59-9116 (950) (370) ---------- (1513) Width Depth in in (mm) (mm) 40-3/8 18-1/8 (1025) (460) Weight Net Ibs (kg) 249 (113) Gross Ibs I (kg) 267 (121) Connection Ratio Tota Indoor Unit Capacity % 60-130 Max indoor units/system — 6 Heat Exchanger Type Multi -Pass Cross - Finned Tube Material — Cu-Al (Anti -corrosion) Compressor Type — HA36PHD-A1S2 Motor Phase / Pol —/— 3PH / 6 Start Method — inverter Operation Range % 10 -100 Refrigeration Oil Type — FVC68D Crank Case Heater WxQty 52W(208V) x1 Fan Electrical-------------------------------- Type — Propeller Fan Quantity City 2 MotorOutput(Pole) W(Pole) 58(10) + 58(10) Air Flow Rate ---------------------------------- Drive Min. Circuit Amps Max Overcurrent Protective Device cfm (m3/min) ---------------- — A ----------------- A 3177 (90) ---------------------- Direct -drive 31 --------------------- 40 Sound Pressure Level *3 Protection devices Cooling (Night -Shift) dB(A) 51 1 (44) Heating Cycle dB(A) ------------- — 52 ------------------------- High pressure switch at 601 psi (4.15MPa) Compressor — Over -current protection Over -heat protection Circuit Breaker (30A) Fan Motor — Over -current protection Over -heat protection Self-contained fuse (5A) PCB (Control Circuit) — Fuse on PCB(5A) Refrigerant Type — R41OA Charage amount Ibs (kg) 7.9 (3.6) Refrigeration Oil Charage amount gal/Unit (¢/Unit) 0.34 (1.3) Defrost Method — Reversed Refrigerant Cycle Main Refrigerant Piping as Line in (mm) 5/8 (15.88) Liquid Line in (mm) 3/8 (9.52) 1of4 © 2017 Johnson Controls, Inc. version 201710 Specifications subject to change NOTES: *1. Rating conditions are based on the AHRI testing standard. See www.ahrinet.org for more information: Cooling Indoor Air Inlet Temperature: 80OF (26.70C)DB 67°F (19.4°C)WB Outdoor Air Inlet Temperature: 95°F (35.0°C)DB Heating Indoor Air Inlet Temperature: 70OF (21.10C)DB Outdoor Air Inlet Temperature: 470F (8.30C)DB 430F (6.1°C)WB Piping Length: 24ft. 7-3/16in. (7.5m) Piping Lift: Oft. (Om) *2 For more details, please referto Engineering manual "Operation range" section. *3 Measurement Point: 3.3ft. (1m) from the air outlet side, 4.9ft. (1.5m) from floor level. The operation sound is measured in an anechoic chamber. However, the actual operation sound may appear louder or with an echo because of surrounding environmental noise. Be sure to check environmental conditions before installation. The sound of the air inlet side is 3dB higher than that of the air outlet side. System Dimensions 36,000 BTU/H Mini VRF Outdoor Unit Model: (Y, H) VAHP036B21 S Air Inlet 2 —4/> i 8-7A1 8P 2XU Cut Halei for Aoahar Bolk 1df10j \ � A � «� Hold f4t COad9aldie Dtaie [WO untina PQeitlOIn pr Brain n d M.Ptp1 to [0241 ) Hole for Gondeneate Graln Z—a/Ll ;Yj1F 71 /34 5E. 4 >•Illlllllll��r�lll�llllllllllll�� i 2XK4)les for Anah�IL • A side view Hu le rnr Refrigerant lf� [1S. S1 Q [dl] o-- 2 of 4 1—l3de Hole for BiNtriperant Plpin T y w \ M 40 f 4 3-1/14110 L 33/1e AMt—WIN a� 71 Drain Water Drain water is caused during heating operation or defrost operation. 9hoose a pplace where well drainage is available. r provid9 a groove for drain. 01)o net pnrovide nn uppward elope cram the unit to avola reverse Ilaw of the drain• Gwen gr8 pin dre'n tyatar i& not permisggible. provtde seond dralnpan under the outdoor unit. to oallaet drain +water securely. © 2017 Johnson Controls, Inc. version 201710 Specifications subject to change A I r Outlet a as VO A 1 r Out Iat 37-VB [95e1 Gervloe Cover Kale for Pawer Supply Wiring or Cotwn u A i 4 4 t i o t Cob1a (9X0L-3/as[021. 91 Kaack4LLL-11oL Role iur Rafr1geranL PIpinp Mnbak0uI—EloIeI $-LlfL1 3 of 4 5-Vha f/1 Qarth TarmCaaI [IrfS Sorawl Termiill l B10alk Ligaid Liu9 Betr[garant P 1p JLQ Ca u0autIaa 00 [¢9. 521 FLera Nut R Go Lino Eta frI;trant PiP[rL0 aa&AaaLian OAA1015.-881 F I a r a Hut © 2017 Johnson Controls, Inc. version 201710 Specifications subject to change gervina Cover E p t L291 14-1/0 [3701 W {xxaiae r-Pr Rixidg tit-0 Galt t0 the V4LLI [90th 6Ldig) (M5 Tepp100 Screw) 0 a N h rt3 Kola far power ;supply Wirin Of Gavmtuolaali01 Cable {2K#1-1/3211#77.91 KIlOokOU%-NO1s] AL, 4:t31 [1221 Hola for Retri�erant Piping 1kn0ataut-a010) s_kA (By] i-J6/1a [50 NOTES 1.There era atop valves in the cabinet. 2.When connecting field rofrigarant piping from tha bottom side of tho unit. provide the spaoeimarked with JW for understructures such as foundation to avoid interference. 3.The dimension marked with M indicates the mounting pitch dimension for anchor bolts. 4of4 ColUS LISTED Intertek © 2017 Johnson Controls, Inc. version 201710 Specifications subject to change