REVIEWED BLD-RESUB 2 22810 Edmonds Way Bldg A_210409_SSSplans_s1910027HOLDOWN SCHEDULE
GENERAL STRUCTURAL NOTES
GENERAL STRUCTURAL NOTES continued
1 Deepen the foundation as needed to provide the required holdown embedment into the foundation wall.
See Deatil MHE
2 Fasten to the end framing members of the shearwall, u.n.o.
3 FOUNDATION ANCHOR may be extended with threaded rod and coupler as required.
4 Provide the minimum embedment and edge distances specified by the manufacturer.
5 Attach to (2) 2x studs minimum (lamination connection same as WALL BASE PLATE; stagger nails), u.n.o.
6 See detail HDN for installation.
HOLDOWN / STRAP
FOUNDATION
1,2,4,E
FASTENERS 5
ANCHOR 1,3,4,6
COMMENTS
*STHD14/14RJ
30-16d sinker
N/A
8" Stem
*HTTSKT
26 - *SD #10x21/2
*SB5/8"x24
#HDU8-SDS2.5
20 - #SDS'/4x2'/2
7/8"�T.R.
4x6 Min Post, See detail RFA
#HDU14-SDS2.5
36 - #SDS'/4x2'/2
1"�T.R.
6x6 Min Post, See detail RFA
#MSTC40
36-16d sinker
N/A
equal number of nails to both connected
elements
#MSTC52
48-16d sinker
N/A
equal number of nails to both connected
elements
#MSTC66
68-16d sinker
N/A
equal number of nails to both connected
elements
#MSTC66B3
56-10d sinker
N/A
4x6 Min Post. See detail SB
SHEARWALL SCHEDULE
SW EXP
Notes apply as called out in table below.
1 Anchor bolts embedded at least 7", or expansion anchors embedded at least 4". See detail SWB.
2 *MASAP can be installed instead of sill bolts with washers. When replacing'/2"0 sill bolts use 7-10dx1'/2"
nails (minimum nailing) and when replacing %T sill bolts use 9-10dx1'/2" nails (maximum nailing).
3 See detail SWF. Connections vary depending on condition. 3a Substitute 16d toe nails @ 8"oc for #A35.
4 See detail SWR. Letter designations a, b, & c refer to specific conditions. For gable -end roof
connections see detail SWF.
5 See detail SWB.
6 Abutting panel edges require a 2-2x (lamination connection same as WALL BASE PLATE), 3x, or greater stud.
7 See detail DSW.
8 The plate washer shall extend to within 1/2" of the edge of the bottom plate that receives the sheathing or rim.
At double -sided shearwalls, stagger on both plate edges.
SHEAR FLOW CONNECTIONS / SPACING
S
SILL -TO -
FLOOR -TO -
ROOF -TO -
WALL BASE PLATE
CALL
FOUNDATION 1, 2
SILL &WALL
WALL 4
5
OUT
5/8"0 @ 60"oc or
*A35 @
*H1 @
16d @ 10"oc
A
1/2"0 @ 60"oc
48"oc 3a
24"oc 4a
5/8"0 @ 60"oc or
#A35 @
#LS50 @
16d @ 6"oc
1/2 "0 @ 40"oc
24"oc
36"oc 4b
5/8"0 @ 40"oc or
*A35 @
#LS50 @
16d @ 4"oc
1/2"0 @ 24"oc
16"oc
24"oc 4b
5/8"0 @ 32"oc or
#A35 @
#LS50 @
16d @ 3"oc
D
1/2"0 @ 24"oc 8
16"oc
16"oc 4b
5/8"0 @ 12"oc or
*A35 @
#LS50 @
2-16d @ 2"oc to 4x
:E:]
1/2"0 @ 8"oc 8
6"oc
8"oc 4c
rim/blkg
n/
WALL SHEATHING
CALL
OUT
SHEATHING
THICKNESS
EDGE
NAILS
6
7/16"
8d @ 6"oc
4
7/16"
8d @ 4"oc
3
7/16" 6
8d @ 3"oc
2
7/16" 6
8d @ 2"oc
33
7/16" both
sides 6,7
8d @ 3"oc
CODE All conditions, materials and construction shall conform to the code specified in the DESIGN CRITERIA, or
other codes required by the governing jurisdiction.
PROTECTION Through maintenance and current best practices, provide a building envelope that will preserve
the integrity of the structure throughout it's lifetime.
INSPECTIONS Notify Building Department for inspections required by local jurisdiction.
SOILS Bearing capacity of soil shall be per DESIGN CRITERIA or greater. Footing shall bear on solid undisturbed
level soil devoid of any organic material and below indicated frost line.
COMPACTED FILL shall consist of predominately Well -Graded, granular soil, free of organic material and
debris. Fill should be placed in maximum 8" loose lifts and compacted to a minimum of 95 percent
of the maximum density at optimum moisture content determined by ASTM D-1557 test procedures.
BACKFILL shall be free draining and without organic material and debris from one of the following soil
classes SM-SC, SM, SP, SW, GC, GM, GP, and GW.
FOUNDATIONS AND RETAINING WALLS Extend footings to undisturbed bearing soil. Do not backfill until all
slabs and/or horizontal diaphragms are constructed, otherwise provide temporary bracing to resist movement.
There shall be no machine compaction on the retaining side of the structure for a distance equivalent to 2/3rds
the wall height.
SILL PLATES Use pressure treated 2x plates u.n.o. Embed anchor bolts at least 7" (expansion anchors
4"). Use 3"x3"x0.229" washers. There shall be a minimum of two bolts per piece spaced not more than 6
feet apart, with one bolt located not more than 12" or less than 4" from each end of each piece.
CONCRETE fc = 3000 psi minimum for environmental exposure (2500 psi used in structural design, or
unless greater psi indicated on the plans). 5 1/2 sacks of cement per cubic yard of concrete and a maximum
of 6 gallons of water per 94 lb sack of cement. Maximum slump is 4". Segregation of materials shall be
prevented through proper handling and placement.
REINFORCING STEEL #4 bars and larger shall be Grade 60 deformed bars, and #3 bars shall be
Grade 40 (u.n.o.), in accordance with ASTM A-615. Lap splices 32 bar diameters u.n.o. Welded
wire fabric shall conform to ASTM A-185 and shall be 6x6 - W1.4AN1.4. Lap one full mesh at splices.
CLEAR COVER 3" clr when cast against Earth and 2" clr in all other locations, u.n.o.
See applicable detail(s): RI
FOOTING DRAINAGE Footing drainage per IBC section 1805.4.2 & IRC section R405.1.
WOOD FRAMING in contact with concrete or masonry, or exposed to weather, shall be pressure treated.
Numbers in parenthesis, IE (1-1), refer to corresponding engineering calculations.
CONNECTORS AND FASTENERS Fasteners, including nuts and washers, and connectors in contact
with pressure treated wood shall be hot -dipped zinc -coated galvanized.
EXCEPTION: Plain carbon steel fasteners, including nuts and washers, in SBX/DOT and zinc borate
preservative treated wood in an interior, dry environment shall be permitted.
SOLID SAWN LUMBER shall meet the following minimum grades (u.n.o.) conforming to "WWPA GRADING
RULES FOR WESTERN LUMBER", latest edition:
BEAMS, POSTS, RAFTERS, JOIST
6X and wider DF#1
4X DF#2
2x 10 and greater DF#2
2x 8 and smaller HF#2
WALL STUDS
2x HF#2
ENGIMERED WOOD shall meet the following minimum properties:
Callout E x 106 (psi) Fb(psi) Fc par(psi) Fc perp (psi) Fv(psi)
LSL 1.55E 1900 2050 900 310
PSL 2.2E 2900 2900 625 290
Engineered wood products shall be protected from moisture to preserve their structural integrity.
Provide temporary bracing to avoid permanent deflections resulting from drying under construction
dead loads.
I -JOISTS Connect I -joist to plate using one 10d (0.131" x 3") nail on each side of bottom flange; drive nails
at an agle at least 1 1/2" from end. Connect 1 1/4" LSL rim to I -joists with one 10d (0.131" x 3") nail into
top and bottom flange. Full -depth blocking between joists over shearwalls shall be 1 1/4" min LSL.
TRUSSES Manufactured trusses are a deferred submittal item designed per CODE section 2303.4 and shall
be designed for all loads and load combinations per the CODE. All connections per manufacturer, u.n.o.
If truss layout is changed by manufacturer, please notify this office.
See applicable detail(s): GEB
OVER -FRAMING Unless noted otherwise by truss manufacturer, overframe with 2x4 rafters @ 24" oc.
Post down w/ 2x4 @ 48" oc, staggered. Brace posts over 6-0" tall perpendicular to wide face.
WALL FRAMING & BEARING Walls shall be 2x studs at 16"oc max with double 2x top plate, and 2x base
plate (exterior walls shall be 2x6 u.n.o. & interior walls shall be 2x4 u.n.o.).
Party walls shall be parallel walls with a 1" gap between. Each wall shall be framed with 2x4 studs at 16"oc
max with double 2x top plate, and 2x base plate.
Block all supports solid to the foundation.
See applicable detail(s): BHS TPS
Full cavity blocks shall be required where party walls intersect exterior walls.
See applicable detail(s): EPI
BEAM PENETRATIONS Allowable beam penetrations shall be made in the middle third of the span and the
middle third of the depth. Contact this office for any penetration outside the allowable area.
See applicable detail(s): BP POF
WNG I WARNING
N.T.S.
THIS IS INTENDED TO DRAW ATTENTION TO
FREQUENTLY EXPERIENCED DIFFICULTIES IN CONSTRUCTION:
• LONG LEAD ITEMS
• DIFFICULT FIELD RETROFITS
• LIMITED OPTIONS FOR RETROFITS
WOOD STRUCTURAL PANELS shall meet the performance standards of the "APA" DOC PS1 and PS2 for their
intended application (group 5 species not allowed).
SHEARWALLS are indicated on the plans with a bold dashed line and labeled SW. The following letter
designation refers to the Shearwall Schedule's SHEAR FLOW CONNECTIONS / SPACING table, and the
number designation refers to the WALL SHEATHING table. Multiple combinations of letter and number
designations may be present. Wall Line numbers, shown inside triangles, refer to corresponding
engineering calculations.
Attach rated sheathing (indicated below) to 2x min STUDS spaced no more than 16"oc, u.n.o. See
Shearwall Schedule for minimum thickness and fasteners (thickness at point of fastened edges governs
shear values). All panel edges shall be blocked. Nail intermediate supports @ 12"oc. Do not penetrate
nails past flush. Install squash blocks under the ends of all shearwalls where the framing below does not
provide full bearing. Construct cripple walls same as the shearwall above, and gable -ends same as the
shearwall below.
Rated sheathing:
7/16" OSB rated with a 24/16 span rating.
1/2" CD with a 32/16 span rating.
See applicable detail(s): SWE
ROOF DIAPHRAGM Install either OSB or CD sheathing:
7/16" OSB rated sheathing with a 24/16 span rating;
panel clips required when spacing is greater than 20" oc.
1/2" CD rated sheathing with a 32/16 span rating.
Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows
half the long dimension. Nail all boundaries and supported edges with 8d @ 6"oc and interior supports with
8d @ 12"oc, blocking not required u.n.o.
ROOF -TOP DECK DIAPHRAGM Install minimum
23/32" rated Sturd-I-Floor T&G with a 24oc span rating
Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half
the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior
supports with 10d @ 12" oc, blocking not required u.n.o.
FLOOR DIAPHRAGM Install minimum
23/32" rated Sturd-I-Floor T&G with a 24oc span rating.
Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half
the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior
supports with 10d @ 12" oc, blocking not required u.n.o.
COLLECTORS Diaphragms shall be nailed continuously to drag struts, drag trusses and other collector
elements at boundary spacing, u.n.o.
See applicable detail(s): DTC CS
CONNECTIONS and fasteners shall be per CODE Table 2304.10.1 u.n.o. The symbol, "", indicates a hardware
connector from the most current Simpson Strong -Tie Catalog. Hardware with equivilent or greater capacities
from other manufacturers may be substituted, example you can use USP's Dual Specification Chart to make an
equivilent or greater capacity selection. Install per the manufacturer instructions.
Fasteners and hardware in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized.
NAILS All nails shall be "Standard Common" size per the latest edition of the National Design Specification
for Wood Construction (NDS) u.n.o.
HOLDOWNS See the HOLDOWN SCHEDULE.
See applicable detail(s): HDN HOC
POST CAPS Provide a post cap on isolated columns that most nearly matches the actual member size(s)
U.N.O. Each connection shall have a minimum of (3)10d to the post and (3)10d to the beam.
HANGERS Model numbers will be specified on the plans for conditions that require more than minimum
capacity, otherwise see CONNECTIONS. When a hanger is not specified on the plans, use any size specific
model number that fits that member. Always use MAX NAILING. Hanger to match member size. Notching or
shimming of beam not allowed unless specified.
JOBSITE SAFETY Sound Structural Solutions Inc has not been retained or compensated to provide design
and/or construction review services related to the contractor's safety precautions or to means, methods,
techniques, sequences or procedures for the contractor to perform their work. The undertaking of periodic site
visits by the ENGINEER shall not be construed as supervision of actual construction and not make him responsible
for providing a safe place for the performance of work by the contractor, subcontractors, suppliers or their
employees, or for access, visits, use work, travel, or occupancy by any person.
OWNERSHIP OF DOCUMENTS These drawings and calculations are the intellectual property of Sound Structural
Solutions Inc. These drawings may not be used in whole or in part by any person without permission of Sound
Structural Solutions Inc.
MISCELLANEOUS The contractor shall verify dimensions and conditions at job site. The contractor shall
provide temporary bracing as required until all permanent connections and stiffenings have been installed.
Do not scale drawings. Pre -fabricated items to be handled and installed per manufacturer's recommendations.
WNG
PLAN INSTRUCTIONS
READ THIS FIRST
These plans are organized so that more detailed or specific information is found in the same
way by following the direction shown below:
GENERAL STRUCTURAL NOTES
SCHEDULES, DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES for more
specific information.
SCHEDULES
DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES and SCHEDULES for more
specific information.
DETAILS
PLANS will often refer to GENERAL STRUCTURAL NOTES, SCHEDULES and DETAILS for more
specific information.
PLANS
See the SYMBOL LEGEND as well as ABREVIATIONS AND ACRONYMS for other additional
information used on the PLANS. The term, TYPICAL (or TYP), used with a detail callout or plan note,
indicates that the information specified shall apply in all similar conditions.
IF YOU HA VEANY QUESTIONS OR CONCERNS CONTA CT US IMMEDIA TEL Y.l
We can be reached immediately by phone: (425) 778-1023
For less pressing questions, email us: inbox@ssseng.com
Please help us get to your plans by having this job number handy: s1910027
ABBREVIATIONS AND ACRONYMS
ABV
ABOVE
E.S.
EACH SIDE
O.C.
ON CENTER
A. B.
ANCHOR BOLT
E.W.
EACH WAY
P.T.
PRESSURE TREATED
BLW
BELOW
EA
EACH
REINF
REINFORCEMENT
BLK
BLOCK
E.N.
EDGE NAILING
REQD
REQUIRED
BLKG
BLOCKING
EMBED
EMBEDMENT
SCHED
SCHEDULE
B.N.
BOUNDARY NAILING
EXIST
EXISTING
SIM
SIMILAR
BTM
BOTTOM
FDN
FOUNDATION
STD
STANDARD
BRG
BEARING
FLR
FLOOR
STRUCT STRUCTURAL
BTWN
BETWEEN
FRMG
FRAMING
SW
SHEARWALL
CLR
CLEAR
FTG
FOOTING
THRU
THROUGH
CLTR
COLLECTOR
G.T.
GIRDER TRUSS
TYP
TYPICAL
CONC
CONCRETE
GR
GRADE
U.N.O.
UNLESS NOTED
CONN
CONNECTION
HORIZ
HORIZONTAL
#
OTHERWISE
CONT
CONTINUOUS
MAX
MAXIMUM
VERT
VERTICAL
CTR
CENTER
MFG
MANUFACTURED
w/
WITH
DBL
DOUBLE
MIN
MINIMUM
w/o
WITHOUT
DET
DETAIL
o/
OVER
W.W.F.
WELDED WIRE FABRIC
E. E.
EACH END
oc
ON CENTER
DESIGN CRITERIA
Governing Code 15 IBC Risk Category H
Wind Design Data
Basic Wind Speed (3 sec gust) mph
110
Surface Roughness
B
Wind Exposure Category
B
Earthquake Design Data
Seismic Importance Factor, Ie
1.00
Site Classification
D
Short Period Acceleration, S,
1.263
1-Second Acceleration, S1
0.494
Seismic Design Category
D
Spectral Response Coefficient, Sps
0.842
Spectral Response Coefficient, SD1
0.496
Gravity Load Data
Internal Pressure Coefficient +/-
0.18
Topographic Factor, Kt
1.00
Wind Importance Factor, I
1.00
Seismic Force Resisting System
Table 12.2-1: A-13
2010 Equiv. Lateral Force Procedure
Response Modification Factor, R
6.5 Transverse
6.5 Longitudinal
Seismic Response Coefficient, C,
0.130 Transverse
0.130 Longitudinal
Seismic Base Shear, V
32357 Ibs
Roofs:
loads are psf
Dead
Live
Snow
Trusses (pitched)
*Pitches < 8:12
Top Chord
10
0
25
Bottom Chord
5
0
0
Floors:
loads are psf
Dead
Live
Snow
Joists
12
40
0
Trusses
Top Chord
8
40
0
Bottom Chord
4
0
0
Notes apply as called out in table above.
5 Joists of sawn lumber or wood I -joists.
Soil Data
Allowable Soil Bearing 12000 psf
SSS Number:
s1910027
Project Name:
22810 Edmonds Way
Bldg A
Owner:
Michel Construction
Project Location:
22810 Edmonds Way
Edmonds, WA 98020
Design Professional:
Michel Design
ro
�t N
O V) O
1--1 '
J � �
uJ
Lori Lr)
N
J w
z E
O
V
0)
NU)
V)
Ip z
Z
w
Lon
U
0)
O
LA
Ln
u7
O
0
z
10421
ISTeq-
jt',rj Sj0 NA t
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 11/8/2019
REVISED: 4/9/2021
S1
1-0
[V
O
O
�l
N
�I
c
ra
Ln
L!]
u)
I
N
O
,--i
CV
POST
FTG
101
BASE
8" 0 EXPANSION ANCH,
6" MIN EMBED
a a I I a as
° L7 Q d
PB - POST BOTTOM CONNECTION
N.T.S. PBAE
FOOTING SCHEDULE
CENTER UNDER CONCENTRATED LOAD U.N.O.
F0077d6 SIZE
REINFORCEMENT
ID
WIDTH
LENGTH
THICKNESS
LONGITUDE
TRANSVERSE
(Transverse)
(Longitude)
F2
2'-0"
1 2'-0"
10"
(3)#4's
3 #4's
LONGITUDE REINF
TRANSVERSE REINF Pnc%T Tn FT(;
THICKNESS
LENGTH
WIDTH (LONGITUDE)
(TRANSVERSE)
FOOTING, TYPICAL
N.T.S.
(2)#4 CONT
@ TOP OF WALL
8" U.N.O.
#4 @ 16"oc
VERT
4'-6" MAX
30" MIN #4 CONT
@ 10" oc HORIZ
CONC SLAB
ON GRADE
P.T. SILL PLATE
&A.B.
CONC STEM WALL
fCTRD ON FTG, U.N.O.
FINISH GRADE
#4 @ 16"oc 2'-0"
DOWELS w/ MAX
14" EXTENSION BETWEEN
INTO WALL & STD GRADES 18"
HOOK IN FTG 1 MIN
T (2)#4 CONT
@ BTM OF WALL
CONC FTG•�+-
16" x 8" w/ j 3" CLR
(3) #4 CONT,
U.N.O. ;III III_
NOTES:
-CENTER VERTS AND DOWELS IN STEM WALL
-DEEPEN FOUNDATION AS REQD TO ACCOMODATE FOR HOLDOWN
EMBEDMENTS
-DEEPEN EXCAVATION TO PROVIDE MINIMUM FOOTING DEPTH
FOUNDATION WALL - STEM
N.T.S. FWX
P.T. SILL PLATE
#4 CONT w/in
& A.B.
TOP 12" OF WALL
CONC STEM WALL
8 U.N.O.
CTRD ON FTG, U.N.O.
FINISH GRADE
4'-6" MAX #4 @ 48"oc
16 MIN VERT
#4 @ 48"oc 2'.0"
DOWELS w/ MAX
#4 AT BTM
14" EXTENSION BETWEEN
CONC SLAB
INTO WALL & STD GRADES 18"
ON GRADE
HOOK IN FTG 1 MIN
CONC FTG" " -
LI
16" x 8" w/ �, I I I 13 CI 1=I I I
(2) #4 CONT, i
U.N.O. ��1���1�1-
NOTES:
-CENTER VERTS AND DOWELS IN STEM WALL
-DEEPEN FOUNDATION AS REQD TO ACCOMODATE FOR HOLDOWN
EMBEDMENTS
FWS FOUNDATION WALL - STEM
N.T.S.
FWSC
FTG @ WALL
FTG @ WALL CORNER
FTG UNDER SLAB ON GRADE
FTGC
e
HOEDOWN
HOLDOWN ANCHOR e ANCHOR
/EMMMM
e
FOUNDATION WALL
EMBEDDED STRAP
MINIMUM STEM HEIGHT
REQUIRED TO ACCOMMODATE
ANCHORAGE PER
HOLDOWN SCHEDULE
FOOTING I DEEPEN FOUNDATION AS REQD TO
ACCOMODATE FOR HOLDOWN
L — — — EMBEDMENTS INTO WALL
MHE I MINIMUM HOLDOWN EMBEDMENT
N.T.S.
GR BEAM
rnnTrklnn REINF
MATCH HORIZ
STD 900 HOOK INTO REINF
INTERSECTING GR BEAM 1�-6CORNER BAR @ ALL
OUTER REINF
•
REINF
• 1 WALLS
MHE
STD 900 HOOK INT MATCH HORIZ
INTERSECTING GR BEAM REINF
ALTERNATE EA BAR V-6" CORNER BAR @ ALL
OUTER REINF
REINFORCEMENT AT INTERSECTIONS
N.T.S. RIAA
HOLDOWN POST
t�
I A.B. PER PLAN
7", MIN
STEM WALL SHALL
BE 2'-0" DEEP MIN
1 0
(2) #4 HORIZ CONT
l
@ TOP OF WALL
11" CLC,
TYP T %" x 3" x 3"
A36 BRG PLATE
w/ DBL NUT
'�
(4) #4 x I I
8 4„
REINFORCED FOUNDATION ANCHOR
3/4" = V-0"
RFAC
SSS Number:
s1910027
Project Name:
22810 Edmonds Way
Bldg A
Owner:
Michel Construction
Project Location:
22810 Edmonds Way
Edmonds, WA 98020
Design Professional:
Michel Design
ro
O tA O
1--1 0
J �
LU
Lori Ln
N
w
Z E
O
V
0)
NU)
V)
ip Z
Z
w
Lon
V
O
Ln
V)
O
a
z
10421
GIs e U�
SIO NA
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 11/8/2019
REVISED: 4/9/2021
S2
(8)16d EVENLY SPACED, 16d @ 16" oc
TYP U.N.O. TYP FACE NAILS BEAM
DISCONTINUOUS #CS16 w/,
DBL TOP PLATE (13) 8d NAILS EA END
POST
i
MIN 2x
4'-0" MIN
SPLICE ~I
TOP PLATE SPLICE DISCONTINUOUS DBL TOP PLATE
#LSTA24 OR #CS16 w/
TPS DOUBLE TOP PLATE SPLICE
DIAPHRAGM MIN (9) -10d N.T.S.
FASTENERS PER MEMBER BOUNDARY NAIL ALONG BOUNDARY NAIL ALONG TPSA SSS Number:
U. N.O.
LENGTH OF COLLECTOR LENGTH OF COLLECTOR s19100Z7
EXTENT OF EXTENT OF
COLLECTOR/RIM COLLECTOR COLLECTOR SHEARWALL SHEARWALL Project Name:
TPS SWF SWR
CRIPPLE STUD DOUBLE TOP PLATE 22810 Edmonds Way
DIAPHRAGM PER
Bldg A
BEAM OPTIONAL STRAi STRUCT NOTES
LOCATION
CS1 COLLECTOR SPLICE INTERMEDIATE FRAMING ABUTTING PANEL EDGES Owner:
Michel Construction
N.T.S. CSAB DTC DIAPHRAGM TO COLLECTOR HEADER HEADER
L-i
N.T.S. DTCA
WINDOW Project Location:
WALL w/ STORY ABOVE OPENING 22810 Edmonds Way
DOOR Edmonds, WA 98020
#LSTA24 w/ MIN (9) -10d DBL 2x STUD ENI
FASTENERS PER MEMBER
U.N.O. EDGE NAILING SW SHEATHING Design Professional:
KING STUD Michel Design
zi TRIMMER STUD
DIAPHRAGM COLLECTOR / JOIST COLLECTOR / RIM HOLDOWN
BOUNDARY EMBEDDED
NAILING STRAP
STRAP SHOWN
4" x 4" IS THE MAXIMUM PENETRATION CRIPPLE STUD BASE PLATE SWB SWF
FLOOR DIAPHRAGM
AROUND CORNER OR HOLE THAT CAN BE ADDED TO A SHEARWALL
M
CONTINUOUS STUDS PER SWE SHEARWALL ELEVATION o to
WALL AT PARTY WALL HOEDOWN SCHED SW SHEATHING ,--i
Ll_��
00
EDGE NAILING N.T.S.
FRAMING 2x STUD DRDDD J °`
FLOOR DIAPHRAGM CS2 COLLECTOR SPLICE a �' N
CONTINUOUS
WALL AT PARTY WALL J w �
N.T.S. CSAG o
"_J ROOF DIAPHRAGM #LS50 @ SHEARWALLS #LS50 @ SHEARWALLS z
PER SCHED PER SCHED
HOLDOWN PER STRUCT NOTES V OV
CSP CONTINUOUS SHEATHING AT PARTY WALL 2xSTUD ANCHOR ���G�l 6
12 MIN 48 MIN EDGE NAILS �O� N �
N.T.S. Ln
CSPA #CS16 TO Ln
COLLECTOR & BLOCKING p z Ln
HOC HOLDOWN AT CORNER #H1 @ #H1 @SHEARWALLS
SOLID #H2.5A #H2.5A @ALL �
BOUNDARY NAILS SHEATHING PER SHEARWALLS �
N.T.S. HOCA BLKG MIN @ALL ROOF
PER NOTES NOTES WALL ROOF MEMBERS
MEMBERS E
U.N.O. @ O
DIAPHRAGM SHEARWALLS U
COLLECTOR 2X FLAT BLKG
300 MIN (OR RIM) _/ 6
2x FLAT BLK w/ SHEARWALL a C
SHEARWALL w/ TRUSS OR RAFTER BEARING Ul)
DBL ROW OF — — — cc cn
BOUNDARY NAILS 01 V)
FRMG SWR SHEARWALL ROOF CONNECTIONS x
O
TRUSS N.T.S. 2x4 BRACE @ 48"oc w/ SWRA
CSB COLLECTOR SPLICE TO BLOCKING STRAP L—i
#A35 AT BTM N.T.S.
GEB GABLE -END TRUSS BRACE DIAPHRAGM PER NAILS PERSTRUCT NOTES SW SCHED WALL BASE
N.T.S. GEBA E CONN
PLATECONN (SW ABOVE) (SWWALL BASE EDGE NAILS ABOVE) BOVE) �O 0
#MTS20 MIN w/ SB STRAP TO BEAM FLR RIM/BLKG z
(OR ROOF GABLE) SOLID BLKG OR DIAPHRAGM PER
MIN (7)10d x i%" N.T.S.
TO EA MEMBER cc,
BAB COLLECTOR STRUCT NOTES aoaT
U.N.O. RIM/BLKG ��FGJSTtiR�U���
EDGE NAILS � SjaNAI-
PROVIDE #A35 PER EDGE NAIL PROVIDE
BLK'G @ 48"oc SW SCHED (SW BELOW) BLKG @48" oc
MSTC MST w/ JOIST -WALL w/ JOIST -WALL
COLLECTOR OR RIM STRAP D— STRAP — 4/,, HDU8 PARALLEL DOUBLE -SIDED SHEARWALLS, PARALLEL This space reserved for
INTERIOR SHEARWALLS, &
governing jurisdiction stamps
TOP PLATE I I 3%" EXTERIOR SHEARWALLS EXT SHEARWALLS @ CANTILEVERS SHEARWALL TO FLOOR TO SHEARWALL
4xMIN � RFA SWF SHEARWALL FLOOR CONNECTIONS
WALL 4x6 U.N.O.
CTP COLLECTOR TO TOP PLATE STRAP MAY BE N.T.S. SWFA
LOCATED
N.T.S. CTPD ON INSIDE
SHEATHING PER SCHED MSTC STRAP -(A) MST STRAP-(A)HDU8- A
WALL BASE WALL
PARTY WALL WALL PLATE CONN
SHEATHING PER TOP PLATE 311 (3)2x STUDS U.N.O. 4/6 HTT5KT 71 PER SW SCHED DIAPHRAGM PER
ib #HDU14 � ANCH PER STRUCT NOTES
SCHED WALL STUD OR POST SW SCHED
(4x MIN) 2 2%" 32" RIM/BLKG ANCH PER
ADJACENT TO 2x4 CONTINUOUS SW SCHED
6x6 2x SILL U.N.O.
WALL FRMG PARTY WALLS TOP PLATE; NO U.N.O. 9 RFA PER SW SCHED EDGE NAILS ORIGIN DATE: 11/8/2019
GAP BREAK AT GAP STHD14 1i6 2x SILL U.N.O.
PARTY WALL PER SW SCHED
A.A EXTERIOR TOP PLATE FDN
CONSTRUCT IS CONTINUOUS END STUD FDN REVISED: 4/9/2021
PARTY WALLS TO EXTERIOR WALL
SHEATHING PER ACROSS GAP FIRE BLOCKING o
PLAN VIEW EXTERIOR WALL STHD14- A HTT5KT- A HDU14- B
SCHED PLAN VIEW ELEVATION VIEW - SECTION A -A SHEARWALLS TO FOUNDATION SHEARWALLS TO FLOOR TO FOUNDATION o
rn
DSW DBL SIDED SW AT ADJOINING WALLS EPIJ EXTERIOR WALL & PARTY WALL INTERSECTION HDN HOLDOWNS SWB SHEARWALL BASE PLATE & FOUNDATION CONNECTIONS
N.T.S. DSWA N"_J.T.S. N"_J.T.S. HDNA N"_J.T.S. SWBA L'
N
O
N
'"CS
IQ11; Npl1�G
IF,yGry
WBC I WIND BEAM CORNER (ISOMETRIC)
N.T.S.
WBCE
CUT BEAM VERTICAL
FOR 4 DEPTH OR
PROVIDE SEPARATE 4 d
BEAM FOR EACH SPAN "
0 oo
d
O O
I
BEAM
CAP
POST
BOB BEAM BROKEN OVER BEARING
N.T.S.
DEPTH
BOTTOM PLATE
FLOOR SHEATHING
#PSPN58
PLUMBING
FLOOR
-,— #PSPN516
DBL TOP PLATE
#PSPN516 w/
8-16d NAILS II
TOP PLATE, E.
— PLUMBING
WALL
#CS16
BEAM PER PLAN
FBD WIND BEAM TO DIAPHRAGM
N.T.S. WBD
#PSPN58 w/
1-8d NAIL INTO
BASE PLATE, E.S.
NOTCH AS
REQUIRED
WALL STUD, TYP WALL STUD,
TYP
TOP PLATE NOTCH BOTTOM PLATE NOTCH
PENETRATION OF FRAMING - EXTERIOR WALL
N.T.S.
FOR PSL & LSL, HOLES MUST BE ROUND AND ARE LIMITED TO 2" DIA. UNLESS APPROVED BY THE ENGINEER
DO NOT MAKE PENETRATIONS OR NOTCHES MINIMUM SPACING
IN THE SHADED AREA OF THE BEAM WITHOUT SHALL BE 2x THE PENETRATIONS IN THIS AREA DO NOT
PRIOR APPROVAL OF THE ENGINEER DIAMETER OF THE REQUIRE APPROVAL FROM THE ENGINEER
LARGER HOLE
4 DEPTH
- E(4 DEPTH
4 DEPTH
4 SPAN
SPAN
4 SPAN
BEAM PENETRATIONS, TYPICAL DETAIL
N.T.S.
N
4 SPAN
FRMG
CANTIL
I
FRMG
#CS14 COILED STRAP w/
(24) 0.148 x 2 % NAILS
#MSTC48B3 BENT STRAP w/
(56) 0.148 x 3 NAILS
FRAMING HUNG FROM FRAMING ABOVE
N.T.S.
—""1 & #CS16
6)10d
10WN
REQD
STUDS
FHFA
REQUIRED STUDS
BEAM
2x4 WALL
2x6 WALL
4x & 2-2x (SAWN)
3%x (GLB)
(2) 2x4
(2) 2x6
3%x(MANF)
6x & 3-2x (SAWN)
5%x (GLB)
(3) 2x4
(3) 2x6
5%x(MANF)
8x (SAWN)
64x (GLB)
(4) 2x4
(4) 2x6
7x (MANF)
GIRDER TRUSS
(3) 2x4
(3) 2x6
REQUIRED TRIMMERS
HEADER
2x4 WALL
2x6 WALL
4x & 2-2x (SAWN)
3%x (GLB)
2x4
2x6
3%x(MANF)
6x & 3-2x (SAWN)
5%x (GLB)
----
(2) 2x6
5%x(MANF)
REQD
TRIMMERS
NOTE: BEAR BEAMS ON THE FULL WIDTH AND BREADTH OF THE MINIMUM
SUPPORTS PER TABLES ABOVE UNLESS NOTED OTHERWISE ON THE PLANS
BBEAM &HEADER SUPPORTS
N.T.S.
SSS Number:
s1910027
Project Name:
22810 Edmonds Way
Bldg A
Owner:
Michel Construction
Project Location:
22810 Edmonds Way
Edmonds, WA 98020
Design Professional:
Michel Design
ro
O tA O
1--1 0
J �
LU
Lori
Ln N
w
Z E
O
V
0)
NU)
V)
p Z
Z
w
Lon
V
01
0
O
LA
Ln
V)
O
C
0
z
10421
S1,0 NA t
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 11/8/2019
REVISED: 4/9/2021
S4
ATTACH #WSW -TOW PLATES (PROVIDED) TO FRAMING
AND #WSW PANEL BOTH SIDES USING 0.148 x 2%" NAILS MIN.
ALIGN #WSW -TOW NOTCHES
TOP PLATES OR BEAM WITH BOTTOM OF TOP PLATES
%" MAXIMUM WOOD SHIM.
FOR SHIMS GREATER THAN %",
SEE DET SWH •
WOOD FURRING BLOCK - — — - • •
3" MIN. I
2" MIN— I • #WSW PER PLAN
� I
2"
MIN. I MIN. #SDS%" x 3%" 1FRAMING
ATTACH DOUGLAS FIR WOOD FURRING BLOCK BETWEEN #WSW PANEL
WITH (14) #SDS%" x 33/2" SCREWS OR (14) 0.162 x 33/2" NAILS. MINIMUM BLOCK SIZE
IS 1%" x 11%" x #WSW PANEL WIDTH.
SWT STRONG WALL TOP CONNECTION
N.T.S.
#WSW STRONG WALL INSTALLED ON
ANCHOR BOLTS PER MANUFACTURER'S
RECOMENDATIONS
(2) ASTM A449 HIGH
STRENGTH ANCHOR
BOLTS (0 PER TABLE)
HEX NUT AND
STRUCTURAL WASHER
1%"COVER
1'4' MIN OVERLAP
OF ANCHOR
REINFORCING
STRONG WALL DESIGN NOTES
1. STRONG -WALL WOOD SHEARWALL IS MANUFACTURED AND TRADEMARKED BY "SIMPSON STRONG -TIE COMPANY
INC."HOME OFFICE: 5956 W. LAS POSITAS BLVD. , PLEASANTON, CA 94588 TEL: (800) 999-5099, FAX: (925)
847-1597. "SIMPSON STRONG -TIE COMPANY INC." IS AN ISO 9001-2008 REGISTERED COMPANY.
2. USE OF THIS PRODUCT IS SUBJECT TO THE APPROVAL OF THE LOCAL BUILDING DEPARTMENT.
3. THIS PRODUCT IS PART OF THE OVERALL LATERAL FORCE RESISTING SYSTEM OF THE STRUCTURE. DESIGN OF
THE BUILDING'S LATERAL FORCE RESISTING SYSTEM, INCLUDING THE LOAD PATH TO TRANSFER LATERAL
FORCES FROM THE STRUCTURE TO THE GROUND, IS THE RESPONSIBILITY OF THE DESIGNER.
4. ENGINEER OF RECORD IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS.
5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ELEVATIONS, ETC. PRIOR TO INSTALLATION
OF ANY COMPONENTS FOR THE STRONG -WALL SB SYSTEM. IF ANY DISCREPANCIES ARE FOUND, THEY SHALL BE
BROUGHT TO THE ATTENTION OF THE DESIGNER FOR CLARIFICATION PRIOR TO CONSTRUCTION.
6. INSTALLATION OF PRODUCT SHALL BE DONE IN CONFORMANCE TO THESE DRAWINGS. THE PERFORMANCE OF
MODIFIED PRODUCTS OR ALTERED INSTALLATION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE
DESIGNER.
7. SIMPSON STRONG -TIE COMPANY INC. RESERVES THE RIGHT TO CHANGE SPECIFICATIONS, DESIGNS, AND
MODELS WITHOUT NOTICE OR LIABILITY FOR SUCH CHANGES.
8. ALL HARDWARE CALLED OUT IS SIMPSON STRONG -TIE.
9. SEE ICC-ES ESR-2652 OR CITY OF LOS ANGELES RR25730 AS APPLICABLE FOR ADDITIONAL INFORMATION.
1" MIN.
- FROM EDGE
%" MIN. AT EDGE I I I
I I II
%" MIN. #SDS TIP TO CHASE
I I
INSTALL #SDS q" x 6" SCR-"'"'
THE TOP PER THE SCREW Pi
FULL -HEIGHT ADJACE
FRAMING, E.S.
#W�
1%" MIN.
ROW SPACING
•
QTY OF #SDS SCREWS
REQUIRED
12" WIDE *WSW
8
18" WIDE *WSW
10
24" WIDE *WSW
14
1%" O.C. MIN.
PLAN VIEW
SCREW PATTERN
1IM BLOCK
1" TO 4" SHIM BLOCK
SWH STRONG WALL HEIGHT ADJUSTMENTS
N.T.S.
PLACE WSW12x8 OVER THE ANCHOR BOLTS AND SECURE WITH
WASHER AND HEX NUTS (PROVIDED). SNUG TIGHT FIT REQUIRED;
DO NOT USE AN IMPACT WRENCH. USE 1%" WRENCH FOR 1" NUT
(2) PAIRS OF #3 HAIRPINS @
43/2" oc PER HAIRPIN PLAN
3" MIN EDGE DISTANCE
TO END OF CONCRETE
STEM WALL
EACH #WSW ANCHOR
INSTALLED BETWEEN A
PAIR OF ANCHOR
REINFORCEMENT HOOKS
ASTM A449 ANCHOR
BOLT 0 REQUIRED
12" WIDE *WSW
%"
18" WIDE *WSW
%"
24" WIDE #WSW
1"
MINIMUM EXTENSION OF
ANCHOR SPACING + 2"
FIELD TIE AND SECURE HAIRPINS
DURRING CONCRETE PLACEMENT
10"x 24" MIN FOOTING
PER DETAIL SWAR
8" MIN STEMWALL
PER DETAIL FWX
SWFC STRONG WALL FOUNDATION CONNECTION
N.T.S.
INSET STRONGWALL
TEMPLATE 2"
2" MIN COVER
2'4' MIN
8" MIN STEM WALL PER DETAIL FWX
(2) #4 HOOKS @ 6" APART CENTERED AT
EACH STRONGWALL ANCHOR LOCATION
(TOTAL OF 4 PER STRONGWALL)
2" MIN COVER EA SIDE OF ANCHOR REINFORCEMENT
3 I.D. 10" MIN
3" COVER FTG THICKNESS
6" MIN f
EXTENSION
(TYP)
24" FTG WIDTH U.N.O.
SWAR I STRONG WALL ANCHOR REINFORCEMENT
N.T.S.
HAIRPIN PLAN
DO NOT
INSTALL #WSW
w/o TEMPLATE
EDGE DRILL ZONE
MIDDLE % OF PANEL THICKNESS
HOLES
• MAX. THREE HOLES IN FACE
AND THREE IN EDGE.
• %"-DIAMETER HOLES, MAX.
• 6" D.C., MIN.
NO EDGE HOLES
ALLOWED IN LOWER
26" OF PANEL
NO HOLES ALLOWED IN TOP 8"
OF PANEL
FACE DRILL ZONE
MAINTAIN 1%" MIN. EDGE
DISTANCE FROM CHASE AND
OUTSIDE EDGE, TYPICAL.
NO FACE HOLES
ALLOWED IN LOWER
40" OF PANEL
ALLOWABLE SMALL HOLES
FACE AND EDGE DRILL ZONES
NO HOLES ALLOWED IN TOP
8" OF PANEL
FACE DRILL ZONE
CENTER 4%" OF PANEL FACE
AS SHOWN
12" ABOVE EXISTING HOLE, MIN.
16"
HOLES
• 4 8"-DIA. HOLES, MAX.
24%" • MAX. OF TWO 4 8"-DIA. HOLES
OR ONE 4%" x 12" HOLE.
• NO MINIMUM ON -CENTER
SPACING REQUIRED.
ALLOWABLE LARGE HOLES
IN ADDITION TO ALLOWABLE
SMALL HOLES
NOTES:
1. FOR HEIGHTS NOT LISTED, ORDER THE NEXT TALLEST PANEL AND TRIM TO FIT. MINIMUM TRIMMED HEIGHT
FOR ALL PANELS IS 741/2".
2. ALL PANELS COME WITH TWO PRE -ATTACHED HOLDOWNS, TWO STANDARD HEX NUTS, TWO STRUCTURAL
WASHERS, TWO #WSW -TOW PLATES AND INSTALLATION INSTRUCTIONS.
3. ALL PANELS ARE 31/2" THICK.
TRIM ZONE AND ALLOWABLE HOLES
N.T.S.
DIAMETER
LENGTH
1 36
HS
2Y8 HS ON HIGH
STRENGTH MODELS
0
HEAVY HEX NUT
LENGTH FIXED IN PLACE ON
ALL WSW -AB ANCHOR BOLTS
le
HEAVY HEX NUT
PLATE WASHER
0
HEAVY HEX NUT
WSW
PANEL MODEL
MODEL NO.
DIAMETER
LENGTH
le
WSW12
WSW-ABY8x30
%"
30"
26"
FROM SIMPSON "https://embed.widencdn.net/pdf/plus/ssttoolbox/zi9rub5hpI/WSW1.pdf"
SWABI STRONG WALL ANCHOR BOLT
N.T.S.
'RONGWALL
'LATE 2"
r%CCTCN IUATC
WSW DESIGNED TO PROVIDE Y8" GAP
BETWEEN LSL AT BASE OF WSW AND
CONCRETE. ENSURE CONCRETE IS
LEVEL AND SMOOTH BENEATH PANEL.
GRIND OR FILL AS NECESSARY.
THE STRONGWALL PANEL MUST BE
INSET 2" FROM THE OUTSIDE FACE
OF THE CONCRETE STEM.
SSS Number:
s1910027
Project Name:
22810 Edmonds Way
Bldg A
Owner:
Michel Construction
Project Location:
22810 Edmonds Way
Edmonds, WA 98020
Design Professional:
Michel Design
ro
L1f N
OtA O
oo
J �
LU Ln N
[/] r-4
J w
z E
O
H V
6
NV)
Ln
p z
Z
w
Loon
V
0)
O
Ln
V)
O
C
`yP \'
O
z
.5�6 is eq-r ��Cs
js'Sj SIONAL
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 11/8/2019
REVISED: 4/9/2021
S5
F>
SYMBOL
LEGEND SLEXP
#HOLDOWN MODEL
HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are
wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE.
— — —
CONCRETE WALL AND CONTINUOUS FOOTING
See CONCRETE and REINFORCING BAR specifications per DETAIL FWS.
F_ -1 F2
SPREAD FOOTING
See CONCRETE and REINFORCING BAR specifications per DETAIL FTG.
L — J
— — —
CONCRETE WALL AND CONTINUOUS FOOTING
See CONCRETE and REINFORCING BAR specifications per DETAIL FWX.
WALL WALL WALL WALL WALL
LInE LIpNE LICE LIDNE LICNE
FOUNDATION PLAN
1/4" = 1'-0° DO NOT SCALE - VERIFY ALL DIMENSIONS WITH ARCHITECTURAL SHEETS PRIOR TO CONSTRUCTION
SSS Number:
s1910027
Project Name:
22810 Edmonds Way
Bldg A
Owner:
Michel Construction
Project Location:
22810 Edmonds Way
Edmonds, WA 98020
Design Professional:
Michel Design
ro
O tA O
1--1 o
J �
LLI N
[/]
N
w
Z E
I� O
V
0)
tin U)
V)
0 Z
Z
w
Lon
V
01
0
Q)
LA
Ln
�V)
X
O
C
0
z
10421
GIs Teq-�r ��Cs
S10
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 11/8/2019
REVISED: 4/9/2021
S6
C
DO
DR
WALL WALL WALL
LIANE LIBNE LICE
1st FLOOR SHEARWALLS & FRAMING ABOVE
1/4" = V-0"
DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS
SYMBOL LEGEND SLEXP
-------------------
DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM.
DIAPHRAGM PROJECTION Represents elements such as roof eaves, facades, and the like.
SHEARWALL Represents walls which are shearwalls and shows the extents of that wall. Connections
per the SHEARWALL SCHEDULE.
#HOLDOWN MODEL
HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are
wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE.
POST Indicates the location of a post within walls below framing. Sizes are indicated on the plan. Grades are
indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BHS for posts not indicated on
the plans.
INTERIOR BEARING WALL Indicates interior walls which support repetitive members. Construct per WALL
FRAMING & BEARING in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan.
BEAM or HEADER Represents the location of a beam or header. Sizes are indicated on the plan. Grades are
indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 2-2x6 (or 4x6) U.N.O.
on the plan.
_JAL - u
HANGER Indicates hanger, standard or concealed flange. Provide fasteners in all holes. Reference the GENERAL
STRUCTURAL NOTES for the minimum size hanger. If a different model no. is required, it will be noted on the plan.
JOIST, TRUSS, OR RAFTER Repetitive member symbol points in the direction of the span. The type, size and max
spacing between members will be indicated in bold type with a symbol which is representative of the layout of the
entire level.
SSS Number:
s1910027
Project Name:
22810 Edmonds Way
Bldg A
Owner:
Michel Construction
Project Location:
22810 Edmonds Way
Edmonds, WA 98020
Design Professional:
Michel Design
ro
O tA O
1--1 o
J �
LLI .-.
Lori�
N
J w
Z E
O
V
0)
tin U)
u7
0 Z
Z
w
Lon
V
01
0
Q)
LA
Ln
�u7
X
O
C
0
z
90421
.S'Ve GIs T P�L�
S10
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 11/8/2019
REVISED: 4/9/2021
S7
F>
SYMBOL LEGEND SLEXP
-------------------
DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM.
DIAPHRAGM PROJECTION Represents elements such as roof eaves, facades, and the like.
SHEARWALL Represents walls which are shearwalls and shows the extents of that wall. Connections
per the SHEARWALL SCHEDULE.
#HOLDOWN MODEL
HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are
wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE.
POST Indicates the location of a post within walls below framing. Sizes are indicated on the plan. Grades are
indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BHS for posts not indicated on
the plans.
INTERIOR BEARING WALL Indicates interior walls which support repetitive members. Construct per WALL
FRAMING & BEARING in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan.
BEAM or HEADER Represents the location of a beam or header. Sizes are indicated on the plan. Grades are
indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 2-2x6 (or 4x6) U.N.O.
on the plan.
_JAL - u
HANGER Indicates hanger, standard or concealed flange. Provide fasteners in all holes. Reference the GENERAL
STRUCTURAL NOTES for the minimum size hanger. If a different model no. is required, it will be noted on the plan.
JOIST, TRUSS, OR RAFTER Repetitive member symbol points in the direction of the span. The type, size and max
spacing between members will be indicated in bold type with a symbol which is representative of the layout of the
entire level.
WAL
LINEL
V
WALL WALL WALL WALL
LInE LINNE LSE LICNE
2nd FLOOR SHEARWALLS & FRAMING ABOVE
1/4" = V-0"
DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS
SSS Number:
s1910027
Project Name:
22810 Edmonds Way
Bldg A
Owner:
Michel Construction
Project Location:
22810 Edmonds Way
Edmonds, WA 98020
Design Professional:
Michel Design
ro
O V) O
1--1 o
J � �
LLI ..
Lori�
N
J w
Z E
I� O
V
0)
tin U)
u7
0 Z
Z
Lon
>
O
V
01
0
Q)
LA
Ln
�u7
X
O
C
0
z
10421
.S'VeGIs eq-
S10
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 11/8/2019
REVISED: 4/9/2021
S8
� — L—
HDR
2x12 RAFTR
M
#MS C40
2x12 RA ERS @
24"oc AX
2x12 RA R
#MSTC40
0
L
WLINE
T
WALL
LSE
#MSTC40
3rd FLOOR SHEARWALLS & FRAMING ABOVE
1/4" = V-0"
WALL
LINE
V
DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS
SYMBOL LEGEND SLEXP
-------------------
DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM.
DIAPHRAGM PROJECTION Represents elements such as roof eaves, facades, and the like.
SHEARWALL Represents walls which are shearwalls and shows the extents of that wall. Connections
per the SHEARWALL SCHEDULE.
#HOLDOWN MODEL
HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are
wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE.
POST Indicates the location of a post within walls below framing. Sizes are indicated on the plan. Grades are
indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BHS for posts not indicated on
the plans.
INTERIOR BEARING WALL Indicates interior walls which support repetitive members. Construct per WALL
FRAMING & BEARING in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan.
BEAM or HEADER Represents the location of a beam or header. Sizes are indicated on the plan. Grades are
indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 2-2x6 (or 4x6) U.N.O.
on the plan.
_JAL - u
HANGER Indicates hanger, standard or concealed flange. Provide fasteners in all holes. Reference the GENERAL
STRUCTURAL NOTES for the minimum size hanger. If a different model no. is required, it will be noted on the plan.
JOIST, TRUSS, OR RAFTER Repetitive member symbol points in the direction of the span. The type, size and max
spacing between members will be indicated in bold type with a symbol which is representative of the layout of the
entire level.
8'-0"
N
1 8'-0"'
HDR ---�
#MSTC40
SSS Number:
s1910027
Project Name:
22810 Edmonds Way
Bldg A
Owner:
Michel Construction
Project Location:
22810 Edmonds Way
Edmonds, WA 98020
Design Professional:
Michel Design
ro
O tA O
1--1 o
J �
LLI .-.
Lori�
N
J w
z E
O
V
0)
NU)
V)
Ip z
Z
w
Lon
V
0)
0
O
LA
Ln
u7
O
V I�
P
z
40921 p
.i'�ftjsTe9_
s10NAL�
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 11/8/2019
REVISED: 4/9/2021
S9