APPROVED ENG PLN STM RESUB 1 - BLDG B - SITE PLAN65
4321
AC
C
E
S
S
EDMONDS WAY
SITE PLAN
SCALE: 1"=20'-0"
10.00'
10.00'
15
.
0
0
'
34
0
.
1
4
'
N
1
2
º
4
0
'
2
1
"
E
1
9
5
.
0
8
'
N
2
1
º
2
7
'
5
0
"
E
47
3
.
7
5
'
N
0
3
º
0
9
'
1
1
"
E
L = 1 39 22
Δ = 21º32' 42"
EXISTING ROCKERY
TO BE REMOVED
EXISTING HOUSE
TO BE REMOVED
(2) 10" CHERRY
TO BE REMOVED
10" FIR TO BE
REMOVED 8" FIR TO BE
REMOVED
5' WOOD FENCE
EXISTING SHED &
CONCRETE TO
BE REMOVED
PARKING REQUIREMENTS
(16) 2 BED = 1.8X16 = 28.8
(2) 3 BED = 2X2 = 4
TOTAL REQ. = 33 SPOTS
ACTUAL = 36 SPOTS
EXISTING GRADE
PROPOSED GRADE
LOT COVERAGE
BLD A= 1,971.52 SQ. FT.
BLD B = 3222.00 SQ. FT.
BLD C = 3474.00 SQ. FT.
BLD D = 3334.37
TOTAL SQ. FT. = 12,001.89 SQ. FT.
LOT COVERAGE = 12,001.89/31,226.57 SQ.FT. = 38%
IMPERVIOUS
BUILDING (W/ EAVES) = 13,877.63 SQ. FT.
DRIVEWAY = 8766.79 SQ. FT.
TOTAL = 22644.09SQ. FT.
CD
SLAB: 351.50
SLAB: 351.50
SLAB: 350.00
25.00'
BLD A
BLD B
BLD C
BLD D
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
1
2 3
5
6
7
8
9
10
11
12
13
14
15
16
17
18
15.00'
SLAB: 350.50
SLAB: 351.50
SLAB: 351.50
SLAB: 351.50
VICINITY MAP
P2
478
20.34'
12x16
112.50'
28
.
0
0
'
92
.
0
0
'
30.00'
30.00'
12
9
.
0
0
'
12
6
.
0
0
'
37.00'
BUILDING C:
A: 356.30
B: 357.35
C: 358.28
D: 357.50
AVE GRADE 357.48
MAX HEIGHT 387.48
BUILDING D:
A: 355.15
B: 356.16
C: 357.13
D: 356.00
AVE GRADE 356.11
MAX HEIGHT 386.11
BA
A
B
C
D
358
358
356
354
352
350
348
348
350
352
354
356
356
15.00'
BUILDING B:
A: 351.10
B: 352.59
C: 357.20
D: 356.74
AVE GRADE 354.41
MAX HEIGHT 384.41
BUILDING A:
A: 349.89
B: 348.79
C: 352.25
D: 353.34
AVE GRADE 351.07
MAX HEIGHT 381.07
Mi
c
h
e
l
D
e
s
i
g
n
B
U
I
L
D
I
N
G
D
E
S
I
G
N
PO
B
o
x
1
2
1
5
L
y
n
n
w
o
o
d
,
W
A
9
8
0
4
6
2
0
6
-
9
3
0
-
2
4
4
5
22
8
1
2
E
D
M
O
N
D
S
W
A
Y
ED
M
O
N
D
S
,
W
A
.
9
8
0
2
0
LO
C
A
T
I
O
N
:
PRINTED:
2.4.21
RESUB
Feb 05 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2020-0151
BUILDING B
ENGINEERING DIVISION
APPROVED AS NOTED
__________________02/10/2021
Refer to approved civil construction plans
under fill-grade permit #BLD2020-0017 for
Engineering requirements
Zone __________ Corner ____ Flag ____
Setbacks: Required Actual
Front _______ _______
Sides _______ _______
Rear _______ _______
Other _______ _______
Height _______ _______
RM-1.5
15 143
30
10 10
15 15
29
N N
APPROVED BY PLANNING
Feb 19 2021
APPLIES WITH APPLICABLE
CITY STROMWATER CODE
02/25/2021
Per Drainage Review Done under
the associated fill/grade permit
BLD2020-0017