Loading...
APPROVED ENG PLN STM RESUB 1 - BLDG B - SITE PLAN65 4321 AC C E S S EDMONDS WAY SITE PLAN SCALE: 1"=20'-0" 10.00' 10.00' 15 . 0 0 ' 34 0 . 1 4 ' N 1 2 º 4 0 ' 2 1 " E 1 9 5 . 0 8 ' N 2 1 º 2 7 ' 5 0 " E 47 3 . 7 5 ' N 0 3 º 0 9 ' 1 1 " E L = 1 39 22 Δ = 21º32' 42" EXISTING ROCKERY TO BE REMOVED EXISTING HOUSE TO BE REMOVED (2) 10" CHERRY TO BE REMOVED 10" FIR TO BE REMOVED 8" FIR TO BE REMOVED 5' WOOD FENCE EXISTING SHED & CONCRETE TO BE REMOVED PARKING REQUIREMENTS (16) 2 BED = 1.8X16 = 28.8 (2) 3 BED = 2X2 = 4 TOTAL REQ. = 33 SPOTS ACTUAL = 36 SPOTS EXISTING GRADE PROPOSED GRADE LOT COVERAGE BLD A= 1,971.52 SQ. FT. BLD B = 3222.00 SQ. FT. BLD C = 3474.00 SQ. FT. BLD D = 3334.37 TOTAL SQ. FT. = 12,001.89 SQ. FT. LOT COVERAGE = 12,001.89/31,226.57 SQ.FT. = 38% IMPERVIOUS BUILDING (W/ EAVES) = 13,877.63 SQ. FT. DRIVEWAY = 8766.79 SQ. FT. TOTAL = 22644.09SQ. FT. CD SLAB: 351.50 SLAB: 351.50 SLAB: 350.00 25.00' BLD A BLD B BLD C BLD D 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 15.00' SLAB: 350.50 SLAB: 351.50 SLAB: 351.50 SLAB: 351.50 VICINITY MAP P2 478 20.34' 12x16        112.50' 28 . 0 0 ' 92 . 0 0 ' 30.00' 30.00' 12 9 . 0 0 ' 12 6 . 0 0 ' 37.00' BUILDING C: A: 356.30 B: 357.35 C: 358.28 D: 357.50 AVE GRADE 357.48 MAX HEIGHT 387.48 BUILDING D: A: 355.15 B: 356.16 C: 357.13 D: 356.00 AVE GRADE 356.11 MAX HEIGHT 386.11 BA A B C D 358 358 356 354 352 350 348 348 350 352 354 356 356 15.00' BUILDING B: A: 351.10 B: 352.59 C: 357.20 D: 356.74 AVE GRADE 354.41 MAX HEIGHT 384.41 BUILDING A: A: 349.89 B: 348.79 C: 352.25 D: 353.34 AVE GRADE 351.07 MAX HEIGHT 381.07 Mi c h e l D e s i g n B U I L D I N G D E S I G N PO B o x 1 2 1 5 L y n n w o o d , W A 9 8 0 4 6 2 0 6 - 9 3 0 - 2 4 4 5 22 8 1 2 E D M O N D S W A Y ED M O N D S , W A . 9 8 0 2 0 LO C A T I O N : PRINTED: 2.4.21 RESUB Feb 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2020-0151 BUILDING B ENGINEERING DIVISION APPROVED AS NOTED __________________02/10/2021 Refer to approved civil construction plans under fill-grade permit #BLD2020-0017 for Engineering requirements Zone __________ Corner ____ Flag ____ Setbacks: Required Actual Front _______ _______ Sides _______ _______ Rear _______ _______ Other _______ _______ Height _______ _______ RM-1.5 15 143 30 10 10 15 15 29 N N APPROVED BY PLANNING Feb 19 2021 APPLIES WITH APPLICABLE CITY STROMWATER CODE 02/25/2021 Per Drainage Review Done under the associated fill/grade permit BLD2020-0017