Loading...
ENG COMPACTION REPORT 11.1.21_ &ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION November 2, 2021 Ms. Kendra Leeman (E-Mail) A-1 LANDSCAPING & CONSTRUCTION INC. 20607 SR 9 SE Snohomish, WA 98296 RE: CONSTRUCTION TESTING AND INSPECTION Kisan Edmonds Way 22810 Edmonds Way Edmonds, Washington Dear Mr. Leeman, KA No. 096-21521 In accordance with your request and authorization, our firm performed construction testing and inspection for the above -referenced project. The sampling and testing was performed by our inspectors and reports are included. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, ;KR7AZA;N& TES, INC. eZ Corbett W. Mercer Project Manager/Lab Manager Pacific Northwest Division CWM/lkj 4303 198" Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States 09621521 DFR _ Page 1 of 1 &Associates,Inc. Geotechnical Engineering • Environmental Engineering Construction Testing and Inspection Field Report NO.: 09621521DFR1112021AL DATE: 11/1/2021 Set Count: CONTRACTOR: Al Landscape PROJECT #: 09621521 PERMIT #: PROJECT: Kisan Townhomes INSPECTOR: Amelia Leo LOCATION: 22810 Edmonds Wav JURISDICTION: City of Edmonds KA P.M.: JM WEATHER: Cloud TEMP: 48° F A Krazan representative visited the project site today to test the compaction of aggregate fill. Upon arrival on site, the representative met with the contractor to discuss locations for testing and other relevant information about the aggregate in place. There was one (1) requested location for testing: the NW corner of the site extending into the main road (Edmonds Way). The location was approximately 6-ft below the base of the surrounding asphalt road on a 6" layer of 1 '/-in aggregate from CalPortland. The contractor provided a proctor for the material used as fill. A total of one (1) nuclear gauge tests were taken at a depth of approximately 6-in, and the results met or exceeded the minimum required 95% compaction. Site photos are attached below. See soil compaction report no. 09621521 SCR1112021AL for additional details on nuclear gauge tests. Site Photos Offices Serving the Western United States Lynnwood (425) 485-5519 - Poulsbo (360) 598-2126 - Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Kraaan & Associates. This report indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to foul submittal. By signing this report, our inspector does not accept responsibility for validity of results. The same information has been provided by others on site. The test results apply only to the specific locations, and items inspected or tested. COMPACTION qMJS6pan& Ass ociate s,Inc. REPORT NO.: Geotechnical Engineering - Environmental Engineering Construction Testing and Inspection 09621521SCR110121-AL DATE: 11/1/2021 CONTRACTOR: Al Landscape PROJECT M 09621521 PERMIT #: PROJECT: Kisan Townhomes INSPECTOR: Amelia Leong LOCATION: 22810 Edmonds Wav JURISDICTION: City of Edmonds KA P.M.: JM WEATHER: Cloudy TEMP: 48 [ASTM D 938UCLEAR ENSOMETER SANDCONE ❑ ASTM D115 6 ❑ OTHER LOCATION MAP O Paved Areas: O Building Pad(s) O Utility: 0 Other: Unified Soils Maximum Dry Optimum Curve Classification or Description Density / Rice Moisture A 11 1/4-in minus 136.0 MODE & DENSITY REQUIRED TEST ELEVATION LOCATION CURVE DEPTH (PCF) MOISTURE COMPACTION COMPACTION 1 6' < asphalt base NE corner of site extending into Edmonds Way A 6" 129.3 5.8% 95% 95% EQUIPMENT NO.: B-268 This testing does not preclude the possibility that the soil or hot mix asphalt DAILY AVERAGE STANDARD DENSITY COUNT: 2788 may be loosened by future construction or rainfall events. The compaction tests were performed at the approximate locations and elevations shown, DAILY AVERAGE STANDARD MOISTURE C ` T: 294 and indicate relative compaction at those locations. Horizontal and vertical limits of the compacted areas were determined by others. Our firm does Reviewed By: not guarantee earthwork or paving construction, nor does our work relieve the contractor's responsibility to conform to the approved project plans and specifications. To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. REMARKS: Su perintendent/Representative: Technician: Offices Serving the Western United States Compaction Report Effective 12/15/2020 Lynnwood (425) 485-5519 - Poulsbo (360) 598-2126 - Tacoma (253) 939-2500 The information provided on this report is prcpsred for the exclusive use ofthe chew. This report may not be reproduced in any format wiWout the written permission ofbe client and Knuan&Associates. This report indicates our inspectors observation and testing results based on site conditions and contractor activities.'This information is subject to reviev prior to final submittal, BY suing this report, our inspector does not acceptrespemsbility for validity ofresults. The ssme infornutionhas been provided by others on situ The test results apply only to the specific locations, and items inspected or tested. Page 1 of 1