Loading...
ENG2023-0517 ROW PERMITRIGHT OF WAY EUC PERMIT PERMIT NUMBER City of Edmonds - ENG2023-0517] www.edmondswa.govi Description: COMCAST - OVERLASH THEN BORE NEW UG TO PRIVATE PROPERTY ISSUED: 11/16/2023 Address: 21701 76TH AVE W EDMONDS WA 98026-7536 EXPIRES: 05/16/2024 Permit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00580700002702 NAME TYPE NAME ADDRESS PHONE APPLICANT JESSAMIN SANTOS 410 VALLEY AVE NW, PUYALLUP WA 98371 (206)401-2188 CONTACT JESSAMIN SANTOS - COMCAST 410 VALLEY AVE NW, PUYALLUP WA 98371 (206)401-2188 CONTRACTOR CABLECOM LLC 1316 BONNEVILLE AVE BLDG A, SNOHOMISH WA 98290 (360)668-1300 OWNER HR ACQUISITION I CORPORATION PO BOX 92129, SOUTH LAKE TX 76092 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE - PER PERMIT $45.00 $45.00 ENG - INSPECTIONS $378.00 $378.00 RIGHT-OF-WAY PERMIT - STANDARD $378.00 $378.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. RELEASED BY: MAJ DATE: 11/16/2023 Printed: Thursday, November 16, 2023 9:10:11 AM 1 of 2 RIGHT OF WAY EUC PERMIT PERMIT NUMIJBE City of Edmonds 51 www.edmondswa.gov • • CONDITIONS CONDITION TYPE ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND AND NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT COMPLETE A-1 JOB START E-7 TRAFFIC CTRL X-2 ENGINEERING FINAL** E-7 RESTOR LIMITS Printed: Thursday, November 16, 2023 9:10:11 AM 2 of 2 of EpM041.� RECEIVED RIGHT OF WAY CONSTRUCTION OCT 13 2023 PERMIT APPLICATION CITY OF EDMONDS Complete and submit this Application in accordance with the Submittal DEVELOPMENT /'Vc. is') Requirements outlined in Right -of -Way permit Handout E6�. SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A' instead of leaving blank. All fields required. Incomplete Applications will be denied. SECTION A General • Project Name JB-1335034 Site Address or if no site address use Property Address at NW corner of project area: 21701 76th AVE W, EDMONDS ,WA 98026 Associated Permits: BLD PLN ENG Owner and Entity Holding Name of Company Comcast Cable Communications Management, LLC. Franchise Ordinance No: Point of Contact Jessamin Santos Title Permit Coordinator Address 410 Valley Ave NW City Puyallup State WA Zip 98371 Phone (2o6) 401-2188 Email jessamin_santos@cable.comcast.com Contractor and Authorized Agent of Owner Name of Company Cablecomm, LLC (see note below) Contractor Contacts During Construction Primary Name CHRIS ATKINSON Agent Name Leah Ihlenfeldt Title Construction Supervior Title Permit Coordinator Mobile 36o-926-3437 Address 1316 BONNEVILLE AVE ,BLDG A, Email CHRIS.ATKINSON@CABLECOMLLC.NET City Snohomish State wA Zip 98290 Secondary Name Phone (36o) 668-1300 Title Email leah.ihlenfeldt@cablecomllc.net Mobile City of Edmonds Business License No: NR-o21818 Email State License No: CABLE-971DP ® Contractor verifies it is currently bonded ® Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o. o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as welt ❑ Traffic Control Only (no associated development) X Utility Franchise Work (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) Comcast JB 1335o34 The proposed work in the ROW is to overlash 26o' of 48ct fiber to existing Comcast strand along 76TH AVE W; missile bore new 2" conduit from riser pole in sidewalk to private / replace sidewalk panel per City of Edmonds standards, pull new 48ct fiber 176' to address 21701 76th AVE W. RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF x LF SF NA Alley 72 hours + LF x LF SF NA Parking 72 hours + LF x LF SF NA SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications X cable (fiber) ❑ power ❑ gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have existing overhead infrastructure in the area of work? Yes X No 2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)? X If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility stem? X 5. Does the work involve proposed additions to an aboveground utility stem? If es: X Are the additions for the purpose of serving new commercial development? X Are the additions for the purpose of serving a single-family residential subdivision? X Details of Work to be Completed Yes No 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? If yes, answer the following questions related to project area, i.e. the actual area in which the X project is proposed: 6a. Does your project involve wires/cables/lines? If yes: X How many are existing? 1 1-2 1How many are to be added? 1 City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: X How many poles are existing in the project area? 3 What is the height of the existing Poles? 35-50 How many poles are to be removed? o Are additional poles to be laced? no How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: X How many? I I What is the height of the poles after? Describe the modification rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsibleforall permit fees. APPLICANT SIGNATURE: Je SaW(n , Saht0S APPLICANT PRINTED NAME: Jessamin Santos APPLICANT TITLE: Permit Coordinator NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE 10/11/2023 City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 Right of Way Completed By: Nathan Lindae-Fregoso Address: 21701 76TH AVE W STE 206 EDMONDS WA 98026 Completion Date: 1/30/2023 Right of Way Footages: COMCAST Job Type: Metro E Retail New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 176 New Aerial Fiber: 0 Overlash Fiber: Existing UG Fiber: 0 Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0 Are Additional Pages Needed: No Job Subtype: Fiber Survey Scope: Post -Sale Project Manager: P2 ID: JB0001335034 Legend New Ped ❑ New Vault Existing U/G Existing Aerial New U/G New Aerial ----- Interior Path Exterior Building Path Footage Break Fiber Splice Point Storage Loop Riser Pole Lock Box Footage 150' Text Box Text Callout Arrow New Tap 0 Phase Identifier 0 Power Suppy - Hard Surface Cut • Abandoned Cable �1 Provide Clear Construction Details 1. TIE IN AT SP0554.WALY. 2. BEGIN FIBER OVERLASH DOWN 3 POLES 2 SPANS 260'. 3. BURY NEW 2" CONDUIT TO BUILDING / PULL NEW FIBER. 4. BEGIN NEW INTERIOR PATH THROUGH CEILING 100' FOLLOWING EXISTING COAX DROP. 5. PLACE PROPER FIBER EQUIPMENT IN CUSTOMER STE TELECO CLOSET. SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM W I (RECEIVED I OCT 13 2023 OWNER/CONTRACTOR IS RESPONSIBLE FOR - J CITY OF EDMONDS EROSION CONTROL AND DRAINAGE 11/15/2023- DEVELOPMENT SERVICES DEPARTMENT Private Exterior Completed By: Nathan Lindae-Fregoso Address: 21701 76TH AVE W STE 206 EDMONDS WA 98026 Completion Date: 1/30/2023 Private Exterior Footages: COMICAST Job Type: Metro E Retail New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 0 New Aerial Fiber: 0 Overlash Fiber: 0 Existing UG Fiber: 0 Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0 Are Additional Pages Needed: No Job Subtype: Fiber Survey Scope: Post -Sale Project Manager: P2 ID: JB0001335034 •Provide Clear Construction TIE IN AT SP0554.WALY. 2. BEGIN FIBER OVERLASH DOWN 3 POLES 2 SPANS 260'. 3. BURY NEW 2" CONDUIT TO BUILDING / PULL NEW FIBER. 4. BEGIN NEW INTERIOR PATH THROUGH CEILING 100' FOLLOWING EXISTING COAX DROP. 5. PLACE PROPER1. •UIPMENT IN CUSTOMER STE TELECO CLOSET. SCHEDULE ALL INSPECTIONS THROUGH i New Vault 0 Existing LI/G Existing Aerial New IJ/G Tx - k Aerial eNew �, '�)F• Interior Path ,. 4. Exterior Building Path Footage Break Fiber Splice Point 14 Storage Loop I TR •� Riser •'' ��.{��'f!'I �i �:�. , 'C Pole 14 Lock Box y/ IONA, Ae Footage Text Box Text Callout Arrow New Tap i.� � - -• 1���1� _ � - /ems-..y y- - -. Phase Identifier Power • •Har • Surface Cut �-•.• v- __ - -_- -4 Abandoned . ECEIVED CT 13 2023 ITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TMA ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 Ibs. c 45 MPH 1 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 1 123' 172' 74' 100, 150, PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED MINIMUM TAPER LENGTH = L (feet) Lane Width (feet) Posted Speed (mph) 25 30 35 40 45 50 55 60 65 70 10 105 150 205 270 450 500 550 - - - 11 115 165 225 295 495 550 605 660 - - 12 125 180 245 320 64 6600 660 720 - - Spotter to assist pedestrians through work zone SIGN SPACING = X (FEET) ( 1 ) RURAL HIGHWAYS 60165 MPH 8001± RURAL ROADS 45/55 MPH 500'± RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350'± RURAL ROADS, URBAN ARTERIALS 25/30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200'± (2) URBAN STREETS 25 MPH OR LESS 100'± (2) ALL SIGNS ARE 48" X 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. (1) All spacing may be adjusted to accommodate interchange ramps, at -grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. CHANNELIZING DEVICE SPACING (FEET) R4-7B KEEP W1-41- N20-1 ROAD ER TAN MPH TAPER 24" X 30" 10* WORK 50/60 40 80 B/W 00 RIGHT AHEAD 35/45 30 60 25130 20 40 30' MIN. 20' 100' MAX. R B L/2 X X FOR TMA 0 q q 76th Ave W ° 63 o WORK AREA ° 0 °0 1� o° — — — — — — — — — go o o o — -9 0 12-0 0 0 0 0 0 12 12 — — o -0 Z o— — — Z� °o ®0 71 2ft min. recommended 0 IT] - - - - - - o - —o oi�00000000000000000000° ao a a � X X L/2 L/2 DEVICE SPACING 1/2 DISTANCE FOR ROAD WORK W20-1 / \ LEGEND LANE CLOSED N SIGN LOCATION AHEAD SIGN LOCATION - S MOUNTING ® W20-5L HEIGHT - RECOMMENDED 0 0 0 CHANNELIZING DEVICES EM PROTECTIVE VEHICLE REQUIRED ENGINEERING DIVISION APPROVED AS NOTED %rU (A/O U,44.1 11/15/2023 VV OPPOSING TRAFFIC DEVICES NOTES Maintain (2) 11' Travel Lanes 1. For long term projects, conflicting pavement markings no longer applicable must be removed or obliterated as soon as practicable. Temporary markings shall be used as necessary and signs shall be post mounted. 2. For speed limits of 30 mph or less, use sign W1-3 in lieu of sign W1-4. 3. Extend device taper across shoulder if applicable. 4. Protective vehicle with TMA required for roadways 45 mph or higher. For roads 40 mph or less - shall be a work vehicle placed strategically to shield work area. TYPICAL LANE SHIFT WITH TWO WAY LEFT TURN LANE TCP 22 TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP RECEIVED OCT 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 0 IV SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP WORK ZONE CONDITION (SEE CHAPTER 1.9.10) A - ALLOWED - CONSIDER USING A SPOTTER. *Contractor to keep at B -ALLOWED -SPOTTER RECOMMENDED least one lane open at a CONSIDER ADDITIONAL WARNING SIGNS. time where feasible C - NOT ALLOWED - SEE TCP 14 & 15 FOR ADDITIONAL WORK ZONE REQUIREMENTS. FLAGGERS TO HOLD TRAFFIC FOR OVERLASH CROSSING Approximate hold time of 5 min per crossing attempt. WORK 76th Ave W 11 AREA ------------- - ROAD µZ n BE W n WORK PREPMEO AHEAD _sL ro arov - o V_"E—E KEEP R� SIGHT DISTANCE DATA MINIMUM STOPPING SIGHT DISTANCE = S SPEED LIMIT 25 30 35 40 45 50 55 60 65 70 MPH DISTANCE FEET 155 200 250 305 360 425 495 570 645 730 DISTANCES SHOWN ARE MINIMUMS, USE ADDITIONAL DISTANCE WHEN POSSIBLE. GENERAL LIMITS OF CHANNELIZED INTERSECTION KEEP RIGHT Spotter to assist pedestrians through work zone NOTES: 1. Work vehicle w/beacon located in same quadrant as work location. 2. Repeated access to work lane not allowed. see tcp LEGEND 14 & 15 for work zone requirements - condition "C". WORK VEHICLE W/ WARNING BEACON 3. Restricted sight distance requires additional advance (LOCATE TO SHIELD WORK VEHICLE) warning devices or signs, see sight distance data chart. 05 SPOTTER 4. Recommend working during red phase if signalized. 5. See chapter 1.9.10 - 1.9.11 for additional direction . RECEIVED TYPICAL VERY SHORT DURATION WORK OPERATION ROAD WORK AHEAD signs to be (INTERSECTION APPLICATION) placed on all public road approaches to OCT 13 2023 TCP 29 work area or advance sign area. ENGINEERING DIVISION APPROVED AS NOTED CITY OF EDMONDS DEVELOPMENT ✓..�rt.nn� 11/15/2023 ��� Wa SERVICES DEPARTMENT VV 0 to SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERM/T.COM TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TMA ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT 1 22,000 Ibs. c 45 MPH 1 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 1 123' 172' 74' 100, 150, PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED MINIMUM TAPER LENGTH = L (feet) Lane Width (feet) Posted Speed (mph) 25 30 35 40 45 50 55 60 65 70 10 105 150 205 270 450 500 550 - - - 11 115 165 225 295 495 550 605 1 660 - - 12 125 180 245 320 540 600 Spotter to assist pedestrians through work zone SIGN SPACING = X (FEET) ( 1 ) RURAL HIGHWAYS 60165 MPH 8001± RURAL ROADS 45/55 MPH 500'± RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350'± RURAL ROADS, URBAN ARTERIALS 25/30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200'± (2) URBAN STREETS 25 MPH OR LESS 100' (2) ALL SIGNS ARE 48" X 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. (1) All spacing may be adjusted to accommodate interchange ramps, at -grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. CHANNELIZING DEVICE SPACING (FEET) R4-76 KEEP W1-4L W20-1 ROAD MPH TAPER TANGENT 24" x 30" 50/60 40 80 B W WORK 35145 30 60 RIGHT AHEAD 25130 20 40 30' MIN. 20' 100' MAX. R B L/2 X X FOR TMA 0 q q 63 76th Ave W 0 WORK AREA 0 1PT71 0° goo 0 o - 00 -9 0 12-0 0 0 0 09 0 00 - - 0-M 0- %� - - - - - - - 0 0 ®M p D Z 2ft min. recommended❑ 0 I7 -0oi�0000000000000000000o a a a � X X L/2 L12 DEVICE SPACING 1/2 DISTANCE FOR OPPOSING TRAFFIC DEVICES ROAD NOTES Maintain (2) 11' Travel Lanes WORK 1. For long term projects, conflicting pavement markings no longer AHEAD applicable must be removed or obliterated as soon as practicable. W20-1 Temporary markings shall be used as necessary and signs shall LEGEND LANE be post mounted. CLOSED IN SIGN LOCATION AHEAD 2. For speed limits of 30 mph or less, use sign W1-3 in lieu of sign W1-4. SIGN LOCATION - S MOUNTING W20-51- 3. Extend device taper across shoulder if applicable. ® HEIGHT -RECOMMENDED 0 0 0 CHANNELIZING DEVICES 4. Protective vehicle with TMA required for roadways 45 mph or higher. For roads 40 mph or less - shall be a work vehicle placed strategically I� PROTECTIVE VEHICLE REQUIRED to shield work area. TYPICAL LANE SHIFT WITH TWO WAY LEFT TURN LANE RECEIVED TCP 22 OCT 13 2023 ENGINEERING DIVISION APPROVED AS NOTED Jea (,1�0✓yap 11/15/2023 CITY OF EDMONDS V DEVELOPMENT SERVICES DEPARTMENT 0 0 ry TJ 216th St SW 218th St SW Q co SIDEWALK DETOUR R9-11 24" x 12" B/W SIDEWALOSED AHEAD CROSS HERE R9-9 24" x 12" m B/W �( RK REA SIDEWALK CLOSED R9-11 24" x 12" BAN SIDEWALK CLOSED AHEAD 4 CROSS HERE GENERAL NOTES LEGEND 1. Controls shown are for pedestrian traffic only. 2. Coordinate with impacted transit agencies prior b TEMPORARY SIGN LOCATION to implementing any closures. ® ® ® CHANNELIZING DEVICES 3. Existing ADA facilities must be maintained. See MUTCD Section 6d and figures TA-28 & 29 for additional information. TYPE 2 BARRICADE OR LONGITUDINAL 4. Use of longitudinal channelization or pedestrian devices CHANNELIZATION DEVICES is preferred for closing the pedestrian facility. See MUTCD Section 6F.71 and 1.8 this manual. RECEIVED OCT 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT RECEIVED OCT 13 2023 CITY OF EDMONDS M BuildingPermit.com CITY OF EDMONDS DEVELOPMENT Right -of -Way Application #1388358 - 1335034 - Sound Sleep Health - 2ERVICES DEPARTMENT Applicant First Name Last Name Company Name Jessamin Santos Jessamin Santos - COMCAST Number Street Apartment or Suite Number E-mail Address 410 Valley Ave NW jessamin_santos@cable.comcast.com City State Zip Phone Number Extension Puyallup WA 98371 (206) 401-2188 Contractor Company Name Cablecom LLC Number Street Apartment or Suite Number 1316 BONNEVILLE AVE BLDG A City State Zip Phone Number Extension SNOHOMISH WA 98290 (360) 668-1300 (360) 454-3163 State License Number License Expiration Date UBI # E-mail Address CABLEL*971 DP 8/21/2025 Rn99RSS79 leah.ihlenfeldt@cablecomllc.net Project Location Number Street Floor Number Suite or Room Number 21701 76TH AVE W City Zip Code County Parcel Number EDMONDS 98026 00580700002702 Associated Building Permit Number Tenant Name Additional Information (i.e. equipment location or special instructions)_ Work Location Property Owner First Name Last Name or Company Name * HR ACQUISITION I CORPORATION Number Street Apartment or Suite Number PO BOX 92129 City State Zip SOUTHLAKE TX 76092 Certification Statement - The applicant states: I certify that I am the owner of this property or the owner's authorized agent. If acting as an authorized agent, I further certify that I have full power and authority to file this application and to perform, on behalf of the owner, all acts required to enable the jurisdiction to process and review such application. I have furnished true and correct information. I will comply with all provisions of law and ordinance governing this type of application. If the scope of work requires a licensed contractor to perform the work, the information will be provided prior to permit issuance. Date Submitted: 10/11/2023 Submitted By: Jessamin Santos Page 1 of 2 CITY OF EDMONDS MyBuildingPermit.com Right -of -Way Application #1388358 - 1335034 - Sound Sleep Health - 2 Project Contact Company Name: Jessamin Santos - COMCAST Name: Jessamin Santos Email: jessamin_santos@cable.comcast.com Address: 410 Valley Ave NW Phone #: (206) 401-2188 Puyallup WA 98371 Project Type Activity Type Scope of Work Utility Purveyor Utility Work Disturbance of Surface Project Name: 1335034 - Sound Sleep Health - 2 Comcast JB 1335034 The proposed work in the ROW is to overlash 260' of 48ct fiber to Description of existing Comcast strand along 76TH AVE W; missile bore new 2" conduit from riser pole in Work: sidewalk to private / replace sidewalk panel per City of Edmonds standards, pull new 48ct fiber 176' to address 21701 76th AVE W. Project Details Project Information Job Number 1335034 Page 2 of 2