Loading...
REVIEWED BLD2022-0949+Manufacturer_Specifications_and_Installation_Instructions+7.18.2022_10.27.42_AM+2995145RECEIVED L CH0022L CACZ - SUBMITTAL Jul 18 2022 CITY EDMONDS DEVELOPMENT SERVICES DEPARTMENT N-JAJ"iU, BLD2022-0949 ❑ For Record ❑ For Approval Project Name: NEW CASTLE MECH- COPPER POT BAKERY Project Location: US, WA, EDMONDS Item #. 1020 Quote ID: R2102018 Submitted On: 0112612022 Submitted For., JIM GIVENS Submitted From: NEW CASTLE MECHANICAL Submitted By: Jim Cellini Identity A FREEZER Tag: FREEZER COND UNIT System Description: Split system System Tag: FREEZER By: Date: Product Family. LCH Compressor Brand: Copeland Application: Outdoor Compressor Type: Scroll Temperature Range: Low Temp Compressor Hp: 2 Voltage: (Volts/Ph/Hz) 208-23013160 Compressor Model. ZF07K4E-TF5-118 Refrigerant Type: R448A Number of Compressor(s): 1 Piping: Standard Coil Type: Microchannel Ambient Temperature (7) Saturated Suction Temperature ('F) Application Capacity* (BTU/H) Altitude (ft) AWEF Value 95 -20.87 6386.0 0 3.04 Compressor(s) Fan Motors) Electric Ratings RLA LRA Quantity Hp FLA Defrost High or Number of MCA MOPD Evap. Fan Defrost Type Low Amps? Contactors Amps Heater Amps 7.8 58 1 1115 0.5 ELECTRIC DEFROST 20 20 5 15 Receiver 90% Full (Ibs) Fan Blade(s) Approx. Net Diameter Sound Data Weight Liquid Line Suction Standard Over Sized (in) (dB) (Ibs) 0.375 0.625 9 14 63 173 Dimensional Drawing(s) REVIEWED BY CITY OF EDMONDS AIR FLOW UOM: inches 28 I/2 LIQUID SUCTION 19 6 5/16 L-231/2 CL AGENCY LISTINGS C @us t 5 3/8 ---- 3 2 3/4 IIIIIIIIl Page 5 of 12 L CH0022L CACZ - SUBMITTAL LARKIN Project Name: NEW CASTLE MECH- COPPER POT BAKERY Project Location: US, WA, EDMONDS Item A, 1020 Quote ID., R2102018 Submitted On: 0112612022 Submitted For: JIM GIVENS Submitted From: NEW CASTLE MECHANICAL Submitted By: Jim Cellini Identity #: FREEZER Tag: FREEZER COND UNIT System Description: Split system System Tag: FREEZER CABINET AND CONSTRUCTION MICROCHANNEL COIL TECHNOLOGY STANDARD ON ALL UNITS SERVICEABILITY SUCTION SERVICE VALVES FOR HERMETIC AND SCROLL COMPRESSORS LOCATED OUTSIDE THE CABINET FOR QUICK INSTALLATIONS. RECEIVER WITH FUSIBLE PLUG, LIQUID SHUTOFF VALVE AND CHARGING PORT IS STANDARD LARGE ELECTRICAL PANEL FOR EASE OF ACCESS PREFABRICATED WIRING HARNESSES FOR TIGHT CRIMP CONNECTIONS AND CONSISTENT LABELING UNIT STAYS ON IF THE HOOD IS REMOVED FOR SERVICING • SIGHT GLASS IS EASILY VIEWABLE • Brand Label - LARKIN • Coil Selection - MICROCHANNEL COIL Defrost Timer Options - ELECTRIC DEFROST TIMER - PARAGON Suction Line Options - SPORLAN FILTER AND ACCUMULATOR Cabinet Selection - Painted Pressure Options - ADJUSTABLE LOW - FIXED HIGH • Phase Loss Monitor - PHASE LOSS MONITOR Snow Legs - NONE Walls or Obstructions for Horizontal Air Flow AIR _ FLOW W* MIN. QUALITY ALL UNITS ARE COMPLETELY LEAK TESTED IN A HELIUM ENVIRONMENT, BUMP TESTED AND ALLOWED TO CYCLE OFF ON THE HIGH AND LOW PRESSURE CONTROL. EACH UNIT HAS A COPY OF THE RUN DATA SHIPPED INSIDE THE ELECTRICAL PANEL ELECTRICAL CIRCUITS ARE COMPLETELY CHECKED FOR CONTINUITY PIPING IS LAID OUT TO MINIMIZE STRESS AND VIBRATION AND IS PRE -BENT TO ELIMINATE LEAKS ENCAPSULATED, AUTO -RESET, HIGH AND LOW PRESSURE CONTROLS TO ELIMINATE LEAKS (ADJUSTABLE LOW PRESSURE CONTROL STANDARD) PAINTED STEEL CABINETS FOR SUPERIOR STRENGTH AND CORROSION PROTECTION HEAVY DUTY, STEEL, 1-1/2" TALL BASE Motor - FIXED SPEED EC Receiver Options - STANDARD Liquid Line Options - SPORLAN FILTER DRIER AND SIGHT GLASS Discharge Line Options - HEAD PRESSURE VALVE 100# Fused Disconnect - NO FUSED DISCONNECT Crankcase Heater - CRANKCASE HEATER Pre Charged - NONE Hail Guard Factory Installed - NONE Multiple Units with Horizontal Air Flow AIR FLOW AIR FLOW 1 __ W* __ -ft unit width MIN. W* MIN. W* MIN. 4 � *Capacities shown are Application Capacities reflecting nominal operation at 107 TD. For models within the scope of the DOE AWEF (Annual Walk-in Energy Factor) standard, the Net Capacityis determined by the AHRI 1250 test method. DOE will publish this compliance data at www.regulations.doe.gov Page 6 of 12 LEL 0065BS6EMA - SUBMITTAL LARKIN ❑ For Record Project Name: NEW CASTLE MECH- COPPER POT BAKERY Project Location: US, WA, EDMONDS Item A, 1030 Quote ID: R2102018 Submitted On: 0112612022 Submitted For: JIM GIVENS Submitted From: NEW CASTLE MECHANICAL Submitted By. Jim Cellini Identity #: FREEZER Tag: FREEZER EVAP System Description: Split system System Tag: FREEZER ❑ For Approval By: Date: Product Family: LEL Motor type 2 SPEED EC Defrost Type: Electric Number of Fans: 2 Voltage: (Volts/Ph/Hz) 208-230/1/60 Fan HorsePower 1 /20 Refrigerant Type: R448A Fins per Inch 6 Perform Fan Motors) Defrost Heaters) Drain Pan Heater(s) Watts Amps Watts Amps Watts Amps 110 1 2100 9.1 Connections (in.) Weight Coil Inlet Suction External Equalizer Drain Side Port Hot Gas Drain Pan 112 518 114 314 54 7/8" ELECTRICAL KNOCKOUTS 1 11/16 13/8 3 1/8 3 1/16 4 5/16 REFRIGERANT ELECTRICAL 131/4 CONNECTION END CONNECTION END 6 1/8 - � 33 1/47 1 I— 6 1/8 16 7/16 UOM inches 45 1/2 AGENCY LISTINGS V C( us @ AIR FLOW 14 I/ 6 I/16 3/4" MPT 114 NPSI 12 DRAIN CONNECTION 15 3/8 Page 7 of 12 LEL 0065BS6EMA - SUBMITTAL LARKIN Project Name: NEW CASTLE MECH- COPPER POT BAKERY Project Location: US, WA, EDMONDS Item A, 1030 Quote ID., R2102018 Submitted On: 0112612022 Submitted For: JIM GIVENS Submitted From: NEW CASTLE MECHANICAL Submitted By: Jim Cellini Identity #: FREEZER Tag: FREEZER EVAP System Description: Split system System Tag: FREEZER EASE OF INSTALLATION SERVICE • ALL ELECTRICAL COMPONENTS FACTORY WIRED TO TERMINAL BOARD AND IDENTIFIED, MAKING IT EASY TO FIELD WIRE THE UNIT RELIABLE DURABLE HEAVY GAUGE, WHITE PAINTED CABINET CLEANS EASILY AND LOOKS ATTRACTIVE MOLDED FAN GUARD AND ACCESS PANELS ARE MADE OF STRONG, DURABLE, AND NSF AND UL SANITATION RATED PLASTIC MATERIAL • SWEAT CONNECTIONS TO REDUCE POTENTIAL FOR LEAKS PERFORMANCE EC MOTORS STANDARD ON ALL MODELS FOR IMPROVED UNIT EFFICIENCY VERSATILE LARGE DIAMETER DRAIN HOLE (3/4 " ID) IS LOCATED TOWARDS THE BACK OF THE UNIT MINIMAL HEIGHT OF THE LOW PROFILE SERIES MAKES IT IDEAL FOR LOW CEILING COOLERS CABINET DESIGN FEATURES HINGED, REMOVABLE FRONT ACCESS PANELS ON EACH SIDE FOR EASY ACCESS TO ELECTRICAL AND REFRIGERATION COMPONENTS • LIQUID LINE SOLENOID WIRE HARNESS IS FACTORY -INSTALLED FOR QUICK INSTALLATION • MOTORS PLUG INTO WIRING HARNESS FOR EASIER SERVICING HINGED, REMOVABLE DRAIN PAN FOR EASY AND SAFE ACCESS • PRE -DRILLED HOLES ON THE BACK OF THE UNIT FOR ROOM THERMOSTAT QUICK REMOVAL FAN GUARD/MOTOR ASSEMBLY FOR EASY SERVICE OR REPLACEMENT OF AIR MOVER PARTS INTERNAL PANELS ARE ISOLATED FOR QUIET OPERATION INTERNALLY ENHANCED TUBING AND FIN DESIGN FOR HIGHER EFFICIENCY • Brand Label - LARKIN Motor - 2 Speed EC Drain Pan Defrost Voltage - 208-230/1/60 DTFD Option - Fixed • Fan Blade - Standard Fan Guard - Molded Cabinet Type - White Drain Pan Type - White • Controller Option - None Solenoid Voltage - 230 Fin Material - Aluminum Coil Mechanical Option - Sporlan TXV / Sporlan Sol Saturated Suction Temperature - -20 Liquid Temperature - 95 N/A - N/A Customer Specified Valve Type - TXV Valve Family - L Heater Limit Switch - Included t PLAN VIEW 1 V2 H PLAN VIEW AIR FLOW One Evaporator NOTE: H =Total Height evaporator coil surface. t t 1 V2 H 1 V2 H 11/2H 3H 11/2H Two Evaporators "Capacities shown are Application Capacities reflecting nominal operation at 10°F TD. For models within the scope of the DOEAWEF (Annual Walk-in Energy Factor) standard, the Net Capacityis determined by the AHRI 1250 test method. DOE will publish this compliance data at www.regulations.doe.gov Page 8 of 12 L CH0020MCACZ - SUBMITTAL LARKIN Project Name: NEW CASTLE MECH- COPPER POT BAKERY Project Location: US, WA, EDMONDS Item A, 2020 Quote ID., R2102018 Submitted On: 0112612022 Submitted For: JIM GIVENS Submitted From: NEW CASTLE MECHANICAL Submitted By. Jim Cellini Identity #: COOLER Tag: COOLER COND UNIT System Description: Split system System Tag: COOLER ❑ For Record ❑ For Approval By: Date: Product Family: LCH Compressor Brand., Copeland Application: Outdoor Compressor Type: Scroll Temperature Range: Medium Temp Compressor Hp: 2 Voltage: (Volts/Ph/Hz) 208-23013160 Compressor Model., ZS15KAE-TF5-118 Refrigerant Type: R448A Number of Compressor(s): 1 Piping: Standard Coil Type: Microchannel Ambient Temperature (7) Saturated Suction Application Capacity* Altitude Temperature (T) (BTU/H) (ft) AWEF Value 95 22.85 15733.0 0 7.6 Connections (in.) Receiver 90% 1 Fan Blade(s) Diameter Standard Over Sized (in) Sound Data (dB) Approx. Net Weight (lbs) Liquid Line Suction 0.5 0.875 14 20 14 63 221 Dimensional Drawin AGENCY LISTINGS c U us �285/16� LIQUID SUCTION AIR FLOW 3 3/16 � 19 3/4 �6 5/16 ' 002 3/4 115/I6 T T �-231/2 CLJ 3 2 1/16 --4 II/16 UOM: inches Page 9 of 12 L CH0020MCACZ - SUBMITTAL LARKIN Project Name: NEW CASTLE MECH- COPPER POT BAKERY Project Location: US, WA, EDMONDS Item A, 2020 Quote ID., R2102018 Submitted On: 0112612022 Submitted For: JIM GIVENS Submitted From: NEW CASTLE MECHANICAL Submitted By: Jim Cellini Identity #: COOLER Tag: COOLER COND UNIT System Description: Split system System Tag: COOLER CABINET AND CONSTRUCTION MICROCHANNEL COIL TECHNOLOGY STANDARD ON ALL UNITS SERVICEABILITY SUCTION SERVICE VALVES FOR HERMETIC AND SCROLL COMPRESSORS LOCATED OUTSIDE THE CABINET FOR QUICK INSTALLATIONS. RECEIVER WITH FUSIBLE PLUG, LIQUID SHUTOFF VALVE AND CHARGING PORT IS STANDARD LARGE ELECTRICAL PANEL FOR EASE OF ACCESS PREFABRICATED WIRING HARNESSES FOR TIGHT CRIMP CONNECTIONS AND CONSISTENT LABELING UNIT STAYS ON IF THE HOOD IS REMOVED FOR SERVICING • SIGHT GLASS IS EASILY VIEWABLE Preferred Package Code - C0747 Motor - PSC Receiver Options - STANDARD Liquid Line Options - FILTER DRIER AND SIGHT GLASS Discharge Line Options - HEAD PRESSURE VALVE 150# Fused Disconnect - NO FUSED DISCONNECT • Crankcase Heater - CRANKCASE HEATER Pre Charged - NONE • Hail Guard Factory Installed - NONE Walls or Obstructions for Horizontal Air Flow AIR _ FLOW W* MIN. QUALITY ALL UNITS ARE COMPLETELY LEAK TESTED IN A HELIUM ENVIRONMENT, BUMP TESTED AND ALLOWED TO CYCLE OFF ON THE HIGH AND LOW PRESSURE CONTROL. EACH UNIT HAS A COPY OF THE RUN DATA SHIPPED INSIDE THE ELECTRICAL PANEL ELECTRICAL CIRCUITS ARE COMPLETELY CHECKED FOR CONTINUITY PIPING IS LAID OUT TO MINIMIZE STRESS AND VIBRATION AND IS PRE -BENT TO ELIMINATE LEAKS ENCAPSULATED, AUTO -RESET, HIGH AND LOW PRESSURE CONTROLS TO ELIMINATE LEAKS (ADJUSTABLE LOW PRESSURE CONTROL STANDARD) PAINTED STEEL CABINETS FOR SUPERIOR STRENGTH AND CORROSION PROTECTION HEAVY DUTY, STEEL, 1-1/2" TALL BASE Brand Label - LARKIN Coil Selection - MICROCHANNEL COIL Defrost Timer Options - AIR DEFROST TIMER - PARAGON Suction Line Options - SUCTION TUBE ONLY Cabinet Selection - Painted Pressure Options - ADJUSTABLE LOW - FIXED HIGH Phase Loss Monitor - PHASE LOSS MONITOR Snow Legs - NONE Multiple Units with Horizontal Air Flow AIR FLOW AIR FLOW l *W = __ W* _ _-ft unit width MIN. W* MIN. W* MIN. 4 f * Capacities shown are Application Capacities reflecting nominal operation at 10 "F TD. For models within the scope of the DOE AWEF (Annual Walk-in Energy Factor) standard, the Net Capacity is determined by the AHRI 1250 test method. DOE will publish this compliance data at www.regulations.doe.gov Page 10 of 12 LEL 0125AS6AMA - SUBMITTAL LARKIN ❑ For Record Project Name: NEW CASTLE MECH- COPPER POT BAKERY Project Location: US, WA, EDMONDS Item A, 2030 Quote ID: R2102018 Submitted On: 0112612022 Submitted For: JIM GIVENS Submitted From: NEW CASTLE MECHANICAL Submitted By. Jim Cellini Identity #: COOLER Tag: COOLER EVAP System Description: Split system System Tag: COOLER ❑ For Approval By: Date: Product Family: LEL Motor type 2 SPEED EC Defrost Type: Air Number of Fans: 2 Voltage: (Volts/Ph/Hz) 115/1/60 Fan HorsePower 1 /20 Refrigerant Type: R448A Fins per Inch 6 Pet -forma I Motors) Defrost Heaters) Drain Pan Heater(s) 1"an Watts Amps Watts Amps Watts Amps 110 1.8 Connections (in.) PghCoil Inlet Suction External Equalizer Drain Side Port Hot Gas Drain Pan 112 718 114 314 7/8" ELECTRICAL KNOCKOUTS 1 11/16 13/8 3 1/8 3 1/16 4 5/16 REFRIGERANT ELECTRICAL 131/4 CONNECTION END CONNECTION END 6 1/8 - � 33 1/47 1 I— 6 1/8 16 7/16 UOM inches 45 1/2 AGENCY LISTINGS V C( us @ AIR FLOW 14 I/ 6 I/16 3/4" MPT 114 NPSI 12 DRAIN CONNECTION 15 3/8 Page 11 of 12 LEL 0125AS6AMA - SUBMITTAL LARKIN Project Name: NEW CASTLE MECH- COPPER POT BAKERY Project Location: US, WA, EDMONDS Item A, 2030 Quote ID., R2102018 Submitted On: 0112612022 Submitted For: JIM GIVENS Submitted From: NEW CASTLE MECHANICAL Submitted By: Jim Cellini Identity #: COOLER Tag: COOLER EVAP System Description: Split system System Tag: COOLER EASE OF INSTALLATION SERVICE • ALL ELECTRICAL COMPONENTS FACTORY WIRED TO TERMINAL BOARD AND IDENTIFIED, MAKING IT EASY TO FIELD WIRE THE UNIT RELIABLE DURABLE HEAVY GAUGE, WHITE PAINTED CABINET CLEANS EASILY AND LOOKS ATTRACTIVE MOLDED FAN GUARD AND ACCESS PANELS ARE MADE OF STRONG, DURABLE, AND NSF AND UL SANITATION RATED PLASTIC MATERIAL • SWEAT CONNECTIONS TO REDUCE POTENTIAL FOR LEAKS PERFORMANCE EC MOTORS STANDARD ON ALL MODELS FOR IMPROVED UNIT EFFICIENCY VERSATILE LARGE DIAMETER DRAIN HOLE (3/4 " ID) IS LOCATED TOWARDS THE BACK OF THE UNIT MINIMAL HEIGHT OF THE LOW PROFILE SERIES MAKES IT IDEAL FOR LOW CEILING COOLERS CABINET DESIGN FEATURES HINGED, REMOVABLE FRONT ACCESS PANELS ON EACH SIDE FOR EASY ACCESS TO ELECTRICAL AND REFRIGERATION COMPONENTS • LIQUID LINE SOLENOID WIRE HARNESS IS FACTORY -INSTALLED FOR QUICK INSTALLATION • MOTORS PLUG INTO WIRING HARNESS FOR EASIER SERVICING HINGED, REMOVABLE DRAIN PAN FOR EASY AND SAFE ACCESS • PRE -DRILLED HOLES ON THE BACK OF THE UNIT FOR ROOM THERMOSTAT QUICK REMOVAL FAN GUARD/MOTOR ASSEMBLY FOR EASY SERVICE OR REPLACEMENT OF AIR MOVER PARTS INTERNAL PANELS ARE ISOLATED FOR QUIET OPERATION INTERNALLY ENHANCED TUBING AND FIN DESIGN FOR HIGHER EFFICIENCY • Brand Label - LARKIN Motor - 2 Speed EC DTFD Option - None Fan Blade - Standard • Fan Guard - Molded Cabinet Type - White Drain Pan Type - White Controller Option - None • Solenoid Voltage - 115 Fin Material - Aluminum Coil Mechanical Option - Sporlan TXV / Sporlan Sol Saturated Suction Temperature - 25 Liquid Temperature - 95 N/A - N/A Customer Specified Valve Type - TXV Valve Family - L 4 PLAN VIEW 11/2 H PLAN VIEW AIR FLOW1.t N _ - - _ One Evaporator NOTE: H =Total Height evaporator coil surface. 1 1 1 1/2 H 1 1/2 H 11/2H 3H 1 V2H Two Evaporators Capacities shown are Application Capacities reflecting nominal operation at 107 TD. For models within the scope of the DOE AWEF (Annual Walk-in Energy Factor) standard, the Net Capacity is determined by the AHRI 1250 test method. DOE will publish this compliance data at www.regulations.doe.gov Page 12 of 12