Loading...
REVIEWED BLD2022-1689+Manufacturer_Specifications_and_Installation_Instructions+12.6.2022_1.54.19_PM+3254936RECEIVED Dec 13 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-1689 Job: 21-1559 Copper Pot Main St Commons Copperpot Bakery 550 Main St S. Edmonds, WA 98020 wWILCOX I1/M CONSTRUCTION INC Spec Section Title: Submittal Title: HVAC Hood and Fan Contractor: WILCOX CONSTRUCTION, LLC Mike Mclsaac Owner (Primary): Casey Cooper Approved per Casey Cooper, per email 08/08/22. S INC E IS 6 3 Submittal REVIEWED BY CITY OF EDMONDS Spec Section No: Submittal No: 03 Revision No: 0 Sent Date: 2/21/2022 Contractor's Stamp Project Name X WILCOX Copperpot Bakery 21-1559 CONSTRUCTION INC ❑ FOR RECORD AND USE ❑ REVIEWED AS NOTED ❑ REVISE & RESUBMIT ❑✓ REVIEWED BY David Thompson DATE 2/21/2022 SUBMITTAL# 03 SPEC 15-500 This review is only for general conformance of the project and general compliance. Corrections or comments made on these drawings during this review do not relieve Contractor/Subcontractor from compliance with the requirements of the plans and specifications. Contractor is responsible for all dimensions and fabrication to be confirmed and correlated at the job site Architect's Stamp Engineer's Stamp ��3HVI33Aa .7iA ni 9uIsV pnibliu8 � LMGREENHECK Building Value in Air. Printed Date: 11/16/2021 Job: Copper Pot Bakery Mark: EF-1 Model: CUE-160-VG O 28.88 Model: CUE-160-VG Direct Drive Upblast Centrifugal Roof Exhaust Fan Drnvinnchi• CIIF_1R1_I/!: Dimensional Quantity 1 Weight w/o Acc's (lb) 73 Weight w/ Acc's (lb) 79 Weight w/ Acc's and Curb (lb) 98 Standard Curb Cap Size (in.) 22 x 22 Roof Opening (in.) 18.5 x 18.5 Performance Requested Volume (CFM) 2,400 Actual Volume (CFM) 2,400 Total External SP (in. wg) 0.327 Fan RPM 974 Operating Power (hp) 0.36 Elevation (ft) 30 Airstream Temp.(F) 70 Air Density (lb/ft3) 0.075 Tip Speed (ft/min) 4,241 Static Eff. (%) 34 Misc Fan Data Fan Eff. Index (FEI) - Outlet Velocity (ft/min) 1,395 Motor Motor Mounted Yes Size (hp) 1/2 Voltage/Cycle/Phase 115/60/1 Enclosure ODP Motor RPM 1000 Efficiency Rating High Windings 1 FLA (Amps) 6.4 Min. Circuit Ampacity (MCA) 8 Max. Overcurrent Protection (MOP) 15 Short Circuit Current Rtg (SCCR) 5 kA Sound Power by Octave Band 29.75 19.56 41.75 1.75 (12.00) 22.00 SO OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR, ADAPTER, AND/OR HINGE BASE. 1.2 0.9 3 c a) 0.6 U) a) d 0 0.3 '�8� 0.4 0.3 Q 0.2 3 0 a a� co 0.1 m 0.0 0 3 6 9 12 15 18 21 24 27 30 Volume (CFM) x 100 Z�, Operating Bhp point C) Operating point at Total External SP Fan curve - - - - System curve ------- Brake horsepower curve Sound 62.5 125 250 500 1000 2000 4000 8000P74 EP A Sones Data Inlet 72 78 75 71 68 65 59 56 11.5 Notes: All dimensions shown are in units of in. *Please consult factory for actual motor amp draw LwA - A weighted sound power level, based on ANSI S1.4 dBA - A weighted sound pressure level, based on dB I a no attenuation per Octave band at 5 ft -dBA levels are not W.Mc WORLDWIDE licensed by AMCA International OEinniD Sones - calculated using ANSI/AMCA 301 at 5 ft RRTIRCd nlrt ¢� movnmenr °. nnccalmm °a° mmcmnon °• InTERnnTlOnnI. IIIC.''°9 Z:\Robert\CAPS Jobs\Copper Pot Bakery.gfcj CAPS 4.36.1264 Generated by: robert@dorse.com LMGREENHECK Building Value in Air. Printed Date: 11/16/2021 Job: Copper Pot Bakery Mark: EF-1 Model: CUE-160-VG Model: CUE-160-VG Direct Drive Upblast Centrifugal Roof Exhaust Fan Standard Construction Features: - Aluminum housing - Backward inclined aluminum wheel - Aluminum curb cap with prepunched mounting holes - Drain trough - Ball bearing motors (sizes 85-300 and all Vari Green), sleeve bearing motors (sizes 60-80) - Motor isolated on shock mounts - Corrosion resistant fasteners Selected Options & Accessories: Motor - Vari-Green EC motor Control - Dial for balancing Standard Curb Cap Size - 22 Square UL/cUL 705 Listed - "Power Ventilators" Switch, NEMA-1, Toggle, Shipped with Unit Junction Box Mounted & Wired Foam Curb Seal (Factory Applied) Birdscreen: Aluminum, nom. 86% Free Area Unit Warranty: 1 Yr (Standard) Selected Sub Marks See individual submittals for full details GPI-22-G12 Z:\Robert\CAPS Jobs\Copper Pot Bakery.gfcj CAPS 4.36.1264 Generated by: robert@dorse.com LMGREENHECK Building Value in Air. Vari-Green Motor & Control Options Printed Date: 11 /16/2021 Job: Copper Pot Bakery Mark: EF-1 Model: CUE-160-VG An EC motor that uses AC input power and internally converts it to DC power. Potentiometer (dial) mounted on the motor enclosure adjusts the speed (RPM) down 80%. Vari-Green motors feature a soft -start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. Motor Configuration Input Voltage: 115 Speed Reference: Dial on Motor Permanent Dial: Yes Control Configuration Control Type: N/A Transformer: None POWER INPUT BLACK 115 VAC NEUTRAL GROUND JUMPER CLOSED Z:\Robert\CAPS Jobs\Copper Pot Bakery.gfcj CAPS 4.36.1264 Generated by: robert@dorse.com LMGREENHECK Building Value in Air. 20.50 20.50 12.00 24.50 24.50 General Printed Date: 11 /16/2021 Job: Copper Pot Bakery Mark: EF-1 Model: GPI-22-G12 Model: GPI Roof Curb Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure - Constructed of either 18 ga galvanized steel or 0.064 in. aluminum - Straight Sided without a cant - 2 in. mounting flange - 3 lb density insulation - Height - Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: - The maximum roof opening dimension should not be greater than the "Actual' top outside dimension minus 2 in.. - The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. - The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. Tag Qty Model Sizing Method Undersizing (in.) Weight (lb) Shipped Assembled 1 GPI-22 Nominal 1.5 19 Yes Dimensions Nominal Nominal Actual I Actual Actual Actual Hinge Hinge Curb Outside Outside Outside Outside Inside Inside Flange Flange Base Base Height Width Length Width Length Width Length Width Length Width* Length* (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) 12 22 22 20.5 20.5 17 17 24.5 24.5 21 21 May not be applicable Accessories Material Security Bars Liner Insulation (in.) Galvanized No No 1 Z:\Robert\CAPS Jobs\Copper Pot Bakery.gfcj CAPS 4.36.1264 Generated by: robert@dorse.com ��3HVI33Aa .7iA ni 9uIsV pnibliu8 � LMGREENHECK Building Value in Air. GO Type 2, Heat and Condensate Hood Printed Date: 11 /16/2021 Job: Copper Pot Bakery Mark: H-1 Model: GO - 144.00 - S Hood Exhaust Exhaust SP Condensate Model Width (in.) Height (in.) Volume Gutter Length (in.) (in. w.g.) Baffle (CFM) GO 144 48 24 2400 0.077 No Baffle No Selected Opti Option or Ac Mounting Height Section Data: ns & Accessories: 80 in. off Finished Floor Material: 430 SS 100% Construction (Hanger brackets - galvanized steel) Features: Stainless Steel Finish for Higher Corrosion Resistance Section I Length Weight Volume Drain Light Light Type Foot Num. (in.) (LBS) (CFM) SP(in. w.g.) Qty Candles 1 144.00 1 226.000 2400.0 0.077 None 0 na Exhaust Collar Data: Section I Collar TCollar Size (LxW) in. Pos. Off Pos. Off Velocity Mounting Option Num. Num. I or Diameter (in.) Left (in.) Back (in.) (fpm) 1 1 1 36 x 12 1 72 24 800 Factory Mounted Exhaust Collar(s) Z:\Robert\CAPS Jobs\Copper Pot Bakery.gfcj CAPS 4.36.1264 Generated by: robert@dorse.com LMGREENHECK Building Value in Air. 0 C6 0 N 1 C7 0 N r` 0 N r— NSF® Z:\Robert\CAPS Jobs\Copper Pot Bakery.gfcj Generated by: robert@dorse.com Printed Date: 11 /16/2021 Job: Copper Pot Bakery Mark: H-1 Model: GO - 144.00 - S COOKING APPLIANCES Z O U� LL1 LU Z 2 0 Y W 2 W 7 X 0 G)C m C C m C� v D �W y �0 o m o (� m Q� o � o 0 W o m 3 m cQ ci 4.0 24.0 I111ARf, 80.0 ABOVE FINISHED FLOOR MARK: H-1 NOTE: All dimensions are in units of in. Hanger Bracket Locations Sec # Brkt # Distance Off Left (in) Distance Off Front (in) 1 1 3.50 2.50 1 2 47.95 2.50 1 3 95.90 2.50 1 4 140.50 2.50 1 5 3.50 45.50 1 6 47.95 45.50 1 7 95.90 45.50 1 8 140.50 45.50 Bracket Mounting Position for an 8 Bracket Hood 5 6 7 8 BACK FRONT 1 2 3 4 ic L �• O a r�•r CL .. M CD n r G) 70v o CD 0 � � O U_(C N ��3HVI33Aa .7iA ni 9uIsV pnibliu8 � LMGREENHECK Building Value in Air. Model: GRSR Printed Date: 11 /16/2021 Job: Copper Pot Bakery Mark: IH-1 Model: GRSR Standard Construction Features: - Aluminum housing. - Aluminum curb cap with prepunched mounting holes. - Recommended roof opening dimension is at least 2.5 in. larger than the damper size. 1.75 Dimensions Curb Cap Curb Cap Model Size Width Length Weight ID# Tag City Model (in.) A (in.) B (in.) C (in.) D (in.) E (in.) F (in.) (in.) (in.) (lb) 2-1 1 GRSR-24 24 34 38.25 12.75 4 N/A 24.5 34 34 44 Performance Throat Volume Throat Area Velocity ID# Tag Qty (CFM) SP (in. wg) (ft2) min) 2-1 1 2,400 0.065 3.24 741 Construction ID# Flashing Flange Installation Type Insect Screen Birdscreen Material Unit Material 2-1 No Non -Ducted No Galvanized Aluminum Accessories Hood Hinged Insulation Tie Down ID# Curb Cap Curb Seal (in.) Points 2-1 No No None No Roof Curbs ID# Model Height (in.) Width (in.) Length (in.) 2-1 GPI 12 34 34 Width Length Blade Frame Actuator Actuator End Damper ID# Model (in.) (in.) Action Type ctuator Type Quantity Mounting I Switch Mounting 2-1 1 VCD-231 24 1 24 1 Parallel I Channel 1 115 1 Internal I No I Ship Separa Z:\Robert\CAPS Jobs\Copper Pot Bakery.gfcj CAPS 4.36.1264 Generated by: robert@dorse.com LMGREENHECK Building Value in Air. Control Damper Model: VCD-23 DRIVE SIDE 1.25 Max. Printed Date: 11/16/2021 Job: Copper Pot Bakery Mark: IH-1 Model: GRSR Standard Construction Features: - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications - Galvanized 16 ga channel frame - Galvanized blades with reinforcements - Side mounted steel linkage is concealed in the frame to prevent additional pressure drop - Axles are steel and 0.5 in. dia.- Synthetic axle bearings - Width and height furnished approximately 0.25 in. undersized - Field wiring is required to individual components Damper Configuration: ID #: I Tag: Quantity: W (in.): H (in.): Act Qty: 2-1 1 1 24 24 1 Notes: All dimensions shown are in units of in. Width And height furnished approximately 0.25 in. undersize Z:\Robert\CAPS Jobs\Copper Pot Bakery.gfcj CAPS 4.36.1264 Generated by: robert@dorse.com LMGREENHECK Building Value in Air. Model: GPI Printed Date: 11 /16/2021 Job: Copper Pot Bakery Mark: IH-1 Model: GPI Roof Curb Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure - Constructed of either 18 ga galvanized steel or 0.064 in. aluminum - Straight Sided without a cant - 2 in. mounting flange - 3 lb density insulation - Height - Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: - The maximum roof opening dimension should not be greater than the "Actual' top outside dimension minus 2 in.. - The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. - The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. General ID# Tag Qty Model Sizing Method Undersizing (in.) Weight (lb) Shipped Assembled 2-1 1 GPI-34-G12 Nominal 1.5 32 Yes Dimensions Nominal Nominal Actual Actual Curb Outside Outside Outside Outside Flange Flange Height Width Length Width Length Width Length ID# (in.) (in.) (in.) (in.) (in.) (in.) (in.) 2-1 12 34 34 32.5 32.5 36.5 36.5 Accessories ID# Material Security Bars Liner Insulation (in.) 2-1 Galvanized No No 1 Z:\Robert\CAPS Jobs\Copper Pot Bakery.gfcj CAPS 4.36.1264 Generated by: robert@dorse.com