Loading...
2022-05-20 - Flynn Residence - RC415755 7day concrete reportOTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing CONCRETE REPORT Job Number: 22-0309 Report Number: RC415755 Permit Number: BLD2021-0929 Project: Flynn Residence Address: 8229 Talbot Rd, Edmonds Inspector(s): Christopher Simpson -Smith Client: Flynn, Todd & Christi Date: 05/20/2022 Description/Location: Inspected placement of concrete for northwest wall, north wall, interior slab pour back, and exterior footing at south end of house. Rebar Verified: Yes See Comments Mfg: Placement Data Design 0 Actual ❑ Batch Weights/Cubic Yard Supplier: Corliss Cement (Ibs/type): 564# Type: 1/11 Mix Number: S260OA50 Fine Agg. (Ibs): 1530# Slump Spec: 4"±1" Coarse Agg. (Ibs/size): 1553# 3/8" Slag (Ibs): W/C Ratio Spec: 0.479 Coarse Agg. (Ibs/size): Air Spec: 5%±1.5% Coarse Agg. (Ibs/size): Total Yards: 38.5 Fly Ash (Ibs): Placed Via: Line Pump Water (Ibs or gal): 270# Consolidated: Yes Admixtures (specify): 6 oz. AE90 Required Strength: 4000 psi @ 28 days Sampling and Testing Data Time Cubic Water Slump Air % Conc.Temp Ambient Truck Ticket ASTM C 172, C 31 Made Yards Added C 143 C 231 C 1064 Temp No. No. Cast Samples: 1-4 8:30 am 10.50 20 gal. 5" 5.5% 62°F 53°F 0083 176140 Weather: Sunny Slump Range: 5" Air % Range: 5.5% Date Samples Picked Up: 5/23/2022 Initial Curing Method: ASTM c31, Exclude c31-12.1.5 Initial Curing Tmp: ASTM c31, Exclude c31-10.1.2 Comments REINFORCING/PLACEMENT: Conforms: W Does Not Conform: ❑ COMPRESSIVE TEST RESULTS Fracture Type Specimen Test Field Age Size Daily Average Weight Max Load Strength (other Number Date Cure (Days) (in.) Area (Sq.In.) Diam. (In.) (Lbs.) (Lbs.) (psi) than cone) 1 05/27/2022 7 4 x 8 12.57 4.00 8.2 42,980 3420 5 = Discarded Tested in general accordance to: ASTMC39 W ASTMC617 ❑ ASTMC1231 ❑ Copies e I ❑� Client ❑�/ Engineer El Others ❑ ❑4 ijf►"-f�. 0 n, Owner Contractor Technical Responsibility: W Architect W Building Dept Jeff Rabe, Project Manager This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report except in full, without written permission from our firm is strictly prohibited. 6747 M.L. King Way S., Seattle, Washington 98118 — Phone (206) 725-4600 — Fax (206) 723-2221 Form No.: ADMIN-62-04 (Rev 09/06) Page 1 of 1