Loading...
REVIEWED BLD HEATING SIZING FORMRECEIVED Simple Heating System Size: Washington State BLD2021-0929 Jul 26 2021 This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and Ar r MON 'IIEDS LOPME SERVICES Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling IoadsEPAR MENT Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information FLYNN RESIDENCE 1H2D ARCHITECTURE & DESIGN 8229 TALBOT RD, EDMONDS, WA 98026 HEIDI HELGESON: 206-542-3734 7M tflvnn(olsoundmarkewealth.com HEIDI@H2DARCHITECTS.COM Heating System Type: O All other systems O Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions" Design Temperature Instructions Design Temperature Difference (AT) Edmonds AT = Indoor (70 degrees) - Outdoor Design Temp Are--13uilding Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 3,276 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.01 29,482 Glazing and Doors U-Factor X Area = UA Instructions u-0.25 1 0.250 1,347 336.70 Skylights U-Factor X Area = UA Instructions 0.50 u --- Insulation Attic U-Factor X Area = UA Instructions R_qg 0.026 193 5.02 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions R-38Vented 0.027 2,097 56.61 Above Grade Walls (see Figure n U-Factor X Area UA Instructions L R-21 Intermediate �l 0.056 2,594 145.29 Floors U-Factor X Area UA Instructions R-38 � I 0.025 `�l 20 0.49 Below Grade Walls (see Figure n U-Factor X Area UA Instructions R-21 int plus R-5 ci �� 0.028 935 26.17 Slab Below Grade (see Figure v F-Factor X Length UA Instructions No Slab Below Grade in this project. � mmm 0.303 i --- Slab on Grade (see Figure v F-Factor X Length UA Instructions No Slab on Grade in this project. � � --- Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space 1.00 Sum of UA 570.28 Figure 1. Above Grade 46 Envelope Heat Load 26,233 Btu / Hour Sum of UA x AT Air Leakage Heat Load 14,647 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 40,880 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 40,880 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 51,100 Btu/Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump (07101113)