Loading...
REVIEWED BLD2022-0479+STRUCTURAL OBSERVATION+4.14.2022_7.20.37_PM+2804140C � civil & structural engineering & planning RECEIVED Apr 18 2022 BLD2022-0479 ENGINEERING I CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT STRUCTURAL OBSERVATION REPORT Project: Flynn Residence Bridge Assessment Purpose: Structural Observation Location: Talbot Bridge, Edmonds, WA 98026 Date: October 8t", 2020 CG Project: 20320.10 Report: 1 Client: Todd and Christi Flynn General Contractor: NA Field Rep: Dennis Titus, PE, SE & Laura Stafford 1 REVIEWED BY CITY OF ' EDMONDS BUILDING DIVISION ; PURPOSE AND SCOPE Field representatives of CG Engineering was on site on September 15, 2020 to observe existing conditions, gather information, take measurements, and verify the existing framing sizes and layout. The information was then used to analyze the bridge for fire truck loading as required by the local fire district. EXISTING STRUCTURE The existing bridge serves a (1) single family home. The existing structure is a 12ft wide by 18ft long wood -framed vehicular bridge that spans over a small creek. The bridge consists of four (4) double 8x8 pressure -treated girders spaced to align with vehicle tires and 3x12 decking. A 6x6 curb is attached to the decking at each side of the bridge. ANALYSIS Structural calculations for the bridge prepared by McMahan Consulting Engineers and dated 2/9/1983 were provided for our review. The original calculations evaluated the bridge for H2O truck live loading in accordance with AASHTO 1983 Specifications. Our analysis evaluates the bridge under HS20 live load conditions in accordance with AASHTO 2002 and per the recommendations provided by the local fire marshal. The live load cases evaluated included: (A) single 24k axle; and (B) two 16k axles spaced at 4'-0" apart. The decking has also been evaluated for wheel loading distributed per AASHTO Specifications. RECOMMENDATIONS 1. Decking: Wood rot was observed in four (4) decking planks. Other deck planks appeared to have previously been replaced. Our analysis determined that the existing decking is inadequate to support the HS20 loading described earlier in this report. • Replace the decking with new PT 412 DF Select Structural decking Girders: The existing girders appeared to be in good condition at the time of our site visit and appear to be adequate to support the proposed loading based on our analysis. The girders bear on concrete abutments with sufficient bearing area for the proposed loading. • When the decking is replaced, assess the top surface of the girders for wood rot. 250 4th Avenue South, Suite 200 Edmonds, WA 98020 ph.425.778.8500 1 f.425.778.5536 www.cgengineering.com Flynn Residence Bridge Assessment CG Project No. 20320.10 October 8t", 2020 Page 2 of 4 2/2020 DISCLAIMER This observation is the professional opinion of CG Engineering PLLC based on the information available during this assessment or evaluation. This report does not warrant or guarantee that all conditions were discovered at the time of the observation. This report was prepared subject to the standard of care applicable to professional services at the time the services were provided. 250 4th Avenue South, Suite 200 Edmonds, WA 98020 ENGINEERING ph.425.778.8500 1 f.425.778.5536 www.cgengineering.com Flynn Residence Bridge Assessment CG Project No. 20320.10 October 81", 2020 Page 3 of 4 Photo 1-Bridge looking towards Talbot Road Photo 2 - Bridge South Elevation C � ENGINEERING 250 4th Avenue South, Suite 200 Edmonds, WA 98020 ph.425.778.8500 1 f.425.778.5536 www.cgengineering.com Flynn Residence Bridge Assessment CG Project No. 20320.10 October 8t", 2020 Page 4 of 4 Photo 3 — Decking Wood Rot Photo 4 — Girder Bearing Condition C � ENGINEERING 250 4th Avenue South, Suite 200 Edmonds, WA 98020 ph.425.778.8500 1 f.425.778.5536 www.cgengineering.com