Loading...
225SAN042 Equipment Data (REPLACEMENT)225S Preferred Series Single -Stage Heat Pump with Puron® Refrigerant 1-1/2 To 5 Tons Product Data 225SAN042 This unit has been designed utilizing Bryant's non -ozone depleting Puron® refrigerant. Heat pumps with Puron® refrigerant provide a collection of features unmatched by any other family of equipment. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings information. Bryant .......... Industry leading Features / Benefits Efficiency • 14.3 - 15.2 SEER2 / 11.0 - 12.5 EER2 / 7.5 - 8.1 HSPF2 (depending on unit size and indoor combination installed) • Microtube technology refrigeration system • Indoor air quality accessories available Sound • Sound levels as low as 70 dBA Comfort • System supports programmable or standard thermostat controls Reliability • Non -ozone depleting Puron® refrigerant • Scroll compressor • Internal pressure relief valve • Internal thermal overload • Loss of charge switch • Filter drier • Balanced refrigeration system for maximum reliability Durability DuraGuardTM Protection Package: • Solid, durable sheet metal construction • Louvered coil guard Applications • Long -line - up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.) • Low ambient cooling (down to 0°F/-17.8°C) with approved low ambient accessory kits 225S: Product Data MODEL NUMBER NOMENCLATURE 1 2 3 4 2 2 5 S Product Tier $ SEER2 OD Design Family Refrigerant Type 2=HP 2 = Preferred 5 = 14.3 S = Single R410A SEER2 Stage 5 6 7,8,9 10 11 12 A N 018 0 0 A Major Series Voltage Cooling Capacity Feature Special Feature Region A-Z=Major N = 208-230-1 or 018 = 18,000 BTUH (1.5 Tons) 0 = Standard 0 = Standard A = Standard HP Series 208/230-1 024 = 24,000 BTUH (2 Tons) P = 208-230-3 or 030 = 30,000 BTUH (2.5 Tons) 208/230-3 036 = 36,000 BTUH (3 Tons) E = 460-3 042 = 42,000 BTUH (3.5 Tons) 048 = 48,000 BTUH (4 Tons) 060 = 60,000 BTUH (5 Tons) 40 ��/\ • r �� i tiion. . Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the Program For verification of certification for individual products, go to wtnv.ahridireclory.org. L O � C US Quality ISO 9001 �sucuasau Tested AHRI Combination Ratings NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Ratings Database here: www.MyBryantRatings.com CATALOG ORDERING NUMBERS Size 18 24 30 Model Number 225SAN01800A 225SAN02400A 225SAN03000A 36 225SAN03600A 42 225SAN04200A 48 225SAN04800A 60 225SAN06000A Standard Features Feature 18 24 30 36 42 48 60 Puron Refrigerant X X X X X X X Scroll Compressor X X X X X X X Compressor Sound Shield X X X X X X X Field Installed Filter Drier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X High Pressure Switch X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Suction Line Accumulator X X X X X X X Loss of Charge Switch X X X X X X X X = Standard Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2 225S: Product Data Physical Data Unit Size 18 24 30 36 42 48 60 Compressor Type Scroll Refrigerant Puron® (R-410A) Control TXV (Puron® Hard Shutoff) Charge (lb) 5.9 ::L- 1 9.0 9.0 9.9 10.8 13.7 Outdoor Htg. Piston # 42 46 1 52 57 61 65 76 Cond Fan Forward Swept or Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 2346 2652 2652 3550 3716 3716 4779 Motor HP 1/12 1/10 1/10 1/4 1/4 1/4 114 Motor RPM 800 825 825 825 1110 1110 825 Cond Coil Face Area (Sq ft) 15.0 17.2 15.0 15.0 17.2 19.3 25.1 Fins per In. 20 20 20 20 20 20 20 Rows 1 1 2 2 2 2 2 Circuits 6 6 7 7 10 12 12 Valve Connect (In. ID) Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8" Refrigerant Tubes (In. OD) Rated Vaport (0-80 Ft Tube Length) 5/8 5/8 3/4 3/4 7/8 7/8 1 1/8 Rated Liquid Line$ (0-80 Ft Tube Length) 3/8" *. For 15 ft. lineset t. Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset $. See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables. Note: See unit Installation Instruction for proper installation. Vapor Line Sizing and Cooling Capacity Loss Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for HP systems with Puron® refrigerant: Vapor Line Sizing and Cooling Capacity Losses - Puron® Refrigerant 1- Stage Heat Pump Applications Unit Nominal Size (Btuh) Acceptable Vapor Line Diameters (In. OD) Cooling Capacity Loss (%) Total Equivalent Line Length (ft) Standard Application Long Line Application Requires Accessories 25 (7.62) 50 (15.2) 80 (24.4) 80+ (24.4+) 100 (30.48) 125 (38.10) 150 (45.72) 175 (53.34) 200 (60.96) 225 (68.58) 250 (76.20) 18,000 1/2 1 2 3 3 4 6 7 8 9 10 12 5/8 0 0 1 1 1 1 2 2 3 3 3 24,000 5/8 0 1 1 1 2 3 3 4 4 5 6 3/4 0 0 0 0 0 1 1 1 1 1 2 5/8 1 2 3 3 3 4 5 6 7 8 9 30,000 314 0 0 1 1 1 1 2 2 2 3 3 7/8 0 0 0 0 0 1 1 1 1 1 1 5/8 1 2 4 4 5 6 7 9 10 11 13 36,000 3/4 0 0 1 1 1 2 2 3 3 4 4 7/8 0 0 0 0 0 1 1 1 1 2 2 42,000 3/4 0 1 2 2 2 3 4 4 5 6 6 718 0 0 1 1 1 1 2 2 2 3 3 48,000 3/4 0 1 2 2 3 4 5 5 6 7 8 7/8 0 0 1 1 1 2 2 2 3 3 4 3/4 1 2 4 4 5 6 7 9 10 11 12 60,000 7/8 0 1 2 2 2 3 4 4 5 5 6 11/8 0 1 0 0 0 1 1 1 1 1 1 2 Standard Length = 80 ft. (24.4 m) or less total equivalent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 225S: Product Data Refrigerant Piping Length Limitations Maximum Line Lengths: The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for allowable lengths depending on whether the outdoor unit is on the same level, above or below the outdoor unit. Maximum Line Lengths for Heat Pump Applications MAXIMUM ACTUAL LENGTH MAXIMUM EQUIVALENT LENGTH( MAXIMUM VERTICAL SEPARATION ft (m) ft (m) ft (m) Units on equal level 200 (61) 250 (76.2) N/A Outdoor unit ABOVE 200 (61) 250 (76.2) 200 (61) indoor unit Outdoor unit BELOW indoor unit See Table'Maximum Total Equivalent Length: Outdoor Unit BELOW Indoor Unit' *.* Maximum actual length not to exceed 200 ft (61 m) Maximum Total Equivalent Length*{ - Outdoor Unit BELOW Indoor Unit Size Liquid Line Diameter HP with Puron® Refrigerant - Maximum Total Equivalent Length Vertical Separation ft (m) Outdoor unit BELOW indoor unit; w/TXV 0-20 (0-6.1) 21-30 (6.4-9.1) 31-40 (9.4-12.2) 41-50 (12.5-15.2) 51-60 (15.5-18.3) 61-70 (18.6-21.3) 71-80 (21.6-24.4) 18,000 3/8 250* 250* 250* 250* 250* 250* 250* 24,000 3/8 250* 250* 250* 250* 250* 250* 250* 30,000 3/8 250* 250* 250* 250* 250* 250* 250* 36,000 3/8 250* 250* 250* 250* 250* 250* 250* 42,000 3/8 250* 250* 250* 250* 250* 250* 150 48,000 3/8 250* 250* 250* 250* 230 160 — 60,000 3/8 250* 225* 190 150 110 — — *.Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. — = outside acceptable range Long Line Applications An application is considered Long Line when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Heat Pump systems, the chart below shows when an application is considered Long Line. Beyond these lengths, long line accessories are required: HP with Puron® Refrigerant Long Line Description ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 3/8 80 (24.4) 20 (6.1) vertical or 80 (24.4) total 80 (24.4) Note: See Long Line Guideline for details Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 225S: Product Data Accessories KIT NUMBER KIT NAME 18 24 30 36 42 48 60 KAACH1701AAA Crankcase Heater X X X X KAACH1601AAA Crankcase Heater X X S KAATD0101TDR Time Delay Relay X X X X X X X KHAIR0201AAA Isolation Relay X X X X X X X KHALSO401 LLS Solenoid Valve Kit X X X X X X X KHASS0606MPK Snow Stand X X X X X X X KSACY0101AAA Cycle Protector X X X X X X X KSAFT0101AAA Evaporator Freeze Stat X X X X X X X KSAHS2501AAA Hard Start X X X X X X X KSALA0301410 Low Ambient Cooling Pressure Switch X X X X X X X KSALA1001AAA MotorMaster X X X X X X X KSATX0201 PUR TXV Kit X X X KSATX0301 PUR TXV Kit X X KSATX0401 PUR TXV Kit X X KSBTX0201PUR TXV Kit X X X KSBTX0301PUR TXV Kit X X KSBTX0401PUR TXV Kit X X KSASF0201AAA Support Foot Assembly X X X X X X X X = Accessory S = Standard Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 225S: Product Data Accessory Usage Guideline REQUIRED FOR LOW -AMBIENT REQUIRED FOR REQUIRED FOR Accessory COOLING APPLICATIONS LONG LINE APPLICATIONS* SEA COAST APPLICATIONS (Below 55°F / 12.8°C) Standard Standard (Within 2 miles / 3.22 km) Standard Accumulator Ball Bearing Fan Motor Standard Standard Standard Compressor Start Assist Capacitor and Yes Yes No Relay Crankcase Heater Yest Yew No Evaporator Freeze Thermostat Yes No No Hard Shutoff TXV Yes Yes No Isolation Relay Yes No No Liquid Line Solenoid valve No See Long -Line Application Guideline No Motor Master® Control or Yes No No Low Ambient Switch Support Feet Recommended No Recommended *. For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split -System Longline Application Guideline. t. Standard on 3 phase units only Accessory Description and Usage (Listed Alphabetically) 1. Ball -Bearing Fan Motor 6. Low -Ambient Pressure Switch Kit A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when MotorMaster® is used. 2. Compressor Start Assist - Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for single-phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 4. Cycle Protector The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling. 5. Evaporator Freeze Thermostat An SPST temperature -actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added. A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low -ambient temperatures down to 0°F (-18°C) when properly installed and also using wind baffles. Instructions provided in accessory kit. Usage Guideline: A Low -Ambient Pressure Switch or MotorMasterO Low -Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C). 7. MotorMaster® Low -Ambient Controller A fan -speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 0°F/-17.8°C), it maintains condensing temperature at 1001F f10°F (37.81C f5.51Q. Usage Guideline: A MotorMaster@ Low Ambient Controller or Low -Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C). Suggested for all commercial applications. 8. Outdoor Air Temperature Sensor This device enables the thermostat to display the outdoor temperature. This device is also required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for use with compatible Bryant thermostats. 9. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level of the compressor. Usage Guideline: Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft (3 m) apart. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 225S: Product Data Accessory Description and Usage (Listed Alphabetically) Continued 10. Support Feet Four or five stick -on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline: Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 11. Thermostatic Expansion Valve (TXV) A modulating flow -control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available. Usage Guideline: Required to achieve AHRI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 12. Time -Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to AHRI Directory of Certified Product Performance (AHRI Directory). When a Time -Delay Relay (TDR) is called for in the AHRI Directory, use a 30 second TDR for MicroChannel Indoor units and use a 90 second TDR for Round Tube Plate Fin Indoor units. 13. Winter Start Control This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 225S: Product Data Electrical Data UNIT SIZE V/PH OPER VOLTS COMPR FAN MCA MAX FUSET or CKT BRK AMPS MAX MIN LRA RLA FLA 18 208-230-1 253 197 45.7 10.3 0.50 13.4 20 24 59.5 11.1 0.60 14.5 25 30 67.9 14.1 0.60 18.2 30 36 83.1 15.3 1.20 20.3 30 42 110.0 18.6 1.40 24.7 40 48 120.0 25.0 1.52 32.8 50 60 150.0 25.6 1.20 33.2 50 *. Pemnissible limits of the voltage range at which the unit will operate satisfactorily t. Time -Delay fuse. FLA-Full Load Amps LRA-Locked Rotor Amps MCA -Minimum Circuit Amps RLA-Rated Load Amps NOTE: Control circuit is 24-V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with requirements of ASHRAE Standards 90.1 Short Circuit Current Rating (SCCR): 5kA rms Sound Power Level UNIT SIZE STANDARD RATING (dBA) TYPICAL OCTAVE BAND SPECTRUM (dB, without tone adjustment) 125 250 500 1000 2000 4000 8000 18 70 67.8 66.5 66.6 66.8 61.0 57.9 52.7 24 71 66.9 68.2 67.6 66.1 62.5 58.8 52.2 30 71 71.7 69.4 68.5 66.9 61.7 58.7 50.9 36 73 73.4 71.9 70.6 68.6 64.2 58.3 51.3 42 73 73.1 73.2 71.4 67.5 62.7 59.5 53.1 48 73 73.7 72.2 71.2 67.9 62.5 59.5 53.3 60 72 68.6 67.0 67.9 68.5 61.3 58.4 52.3 NOTE: Tested in compliance with AHRI 270 but not listed with AHRI. Charging Subcooling (TXV-Type Expansion Device) HP Only Replacement with Piston Indoors This heat pump may only be installed with piston metered indoor units as replacement components in a piston system. When installing a non -rated heat pump with a piston indoor unit, the correct piston must be installed, which should be listed in the indoor unit Installation Instructions or Product Data. Replacement pistons can be ordered from Replacement Components (RC). Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Dimensions OPERATING SHIPPING SHIPPING SHIPPING UNIT SERIES ELECTRICAL A IS C D E F G H I 3 K WEIGHT WEIGHT LENGTH/ HEIGHT CHARACTERISTICS WIDTH (Sq.) INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM Lbs K s Lbs K s INCH MM INCH MM 2258A'018'OA A Y N N N 31 3/16 792.5 2811/16 728.7 5/8 15.9 6 9/16 166.1 2411/16 626.3 9 1/8 231.3 1 1/8 28.2 313/16 97.4 15 1/2 393.7 15 381.0 13 112 342.9 160 72.5 190 86.4 34 1/4 870.0 3315/16 861.6 225SA'024`OA A Y N N N 31 3/16 792.5 32 1/16 815.1 5/8 15.9 6 9/16 166.1 2411/16 626.3 9 1/8 231.3 1 118 28.2 313116 97.4 14 314 374.7 15 381.0 14 12 368.3 175 79.3 206 93.3 34 1/4 870.0 37 5/16 947.9 225SA'030'OA A Y N N N 31 3/16 792.5 2811/16 728.7 3/4 19.1 6 9116 166.1 2411/16 626.3 9 1/8 231.3 1 1/8 28.2 313/16 97.4 16 406A 16 406A 13 1/4 336.6 198 89.6 228 103.5 34 114 870.0 3315/16 861.6 225SA'036.OA A Y N N N 31 3/16 792.5 2811/16 728.7 314 19.1 6 9/16 166.1 2411/16 626.3 9 1/8 231.3 1 118 28.2 313116 97A 14 314 374.7 16 406A 12 1/4 311.2 200 90.5 230 104.3 34 1/4 870.0 3315116 861.6 225SA'042'OA A Y N N N 31 3/16 792.5 32 1/16 815.1 7/8 22.2 6 9/i6 166.1 2411/16 626.3 9 1/8 231.3 1 1/8 28.2 313/16 97A 16 1/4 412.8 15 12 393.7 13 3/4 349.3 237 107.7 268 121.7 34 1/4 870.0 37 5/16 947.9 2258A'048'OA A Y N N N 31 3/16 792.5 35 12 901.4 7/8 22.2 6 9/16 166.1 2411/16 626.3 9 1/8 231.3 1 1/8 28.2 313/16 97.4 15 114 387.4 14 314 374.7 15 314 400.1 241 111.1 277 125.6 34 1/4 870.0 40 31 1034.3 225SA'060`OA A Y N N N 35 889.0 38 7/8 987.8 7/8 22.2 6 9/16 166.1 28 7/16 722.8 9 1/8 231.3 1 1/8 28.2 313116 97.4 16 12 419.1 17 431.8 18 457.2 287 130.3 321 145.5 3713/i6 960.0 44 1/8 1120.7 W W n Y=YES NOTES: N=NO 1. CENTER OF GRAvFTY m1,1 A so. AIR DISCHARGE / / AIR IN AIR DISCHARGE F � FIELD POWER SUPPLY CONN. B 017/8'(022.2) HOLE WITH AIR IN -AIR IN 1/8'(028.6) KNOCKOUT FIELD CONTROL SUPPLY COON. 01/8'(022.21 HOLE �I\,` E �CONN! LIOU D L/ NE K J 3 3/4' 3 1/2' (96.0) (88.9) y H DOCVAPOR LINE CONN.,Y so. t 3116" f (46.1) 1/' 8 C7 X so. 13.21 }AIR fd3/8'(fb9.5) TIEDOWN KNOCKOUTS L (2) PLACES 2 3/16 ' IN (55.6) UNIT SIZE MVM.IM GROUND MDUNG9G MINIMIM ROOFTOP MOUNRNG MDARIICATDN DIM9SIONS P.ADAPFLIGATDNDRi UNS 23 1/8 587.3 17 7/8 454.6 25 3/4 654.0 20 7/16 518.5 18,24,30,36,42,48 31 3/16 26 NOTE: ALL DIMENSIONS IN INCH (MM) U.S. ECCN: Not Subject to Regulation (N.S.R.) 60 3/4 679.2 889.5 35 889.0 26 3/4 679.7 8D57823 REV.A Clearances 24" (609.6) Service 24" (609.6) 1 ��F111 6" (152.4) 12" (304.8) 24" (609.6) 12" (304.8) 24" (609.6) Clearances (various examples) 24" (609.6) Service wall 24 (*609.6)" Service 12" 6" (304.8) (152.4) W 12" (304.8) 24" (609.6) 24" (609.6) Note: Numbers in () = mm Allow 48" above unit IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re -circulation of discharge air. d 0 CD CD CD 0) S CD S 0 v to SD Balance Point Worksheet 80 H U a V 70 C7 Z Q 60 W 2 0 F- 50 a C7 = W Z 00 40 H � Z 30 C U) O J F- 20 Q W 2 Z 10 0 J_ m 0 225SAN060**Ad FJ4DNXD60L* i 25SAN048**A J4DNXC48L* 225SAN042**A FJ4DNXC42L* 225SAN036**A FJ4DNXB36L* 225SAN030**A FJ4DNXB30L* 225SAN024**A FJ4DNXB24L* 225SAN018**A FJ4DNXA18L* BASED ON INDOOR ENT. AIR AT 70 OF AND AT RATED CFM -10 0 10 20 30 40 50 OUTDOOR TEMPERATURE, OF 60 70 23.4 20.5 17.6 14.6 11.7 Y 5.9 WE MIS DETAILED COOLING CAPACITIES# EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75.0 (23.9) 85.0 (29.4) 95.0 (35.0) 105.0 (40.6) 115.0 (46.1) 125.0 (51.7) CFM EWB Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW** 225SAN01800A Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW * Capacity MBtuh Total Sys. KW" Total Sens$ Total Sens$ Total • utdoor Sens$ Total Sens$ Total Sens$ Total Sens$ 72.0 (22.2) 20.65 10.58 1.15 19.67 10.21 1.30 18.65 9.83 1.47 17.57 9.44 1.65 16.37 9.00 1.87 15.06 8.54 2.11 67.0 (19.4) 18.74 13.02 1.17 17.84 12.65 1.31 16.91 12.27 1.48 15.92 11.87 1.66 14.84 11.44 1.88 13.64 10.96 2.12 525 63.0 (17.2)tt 17.37 12.52 1.18 16.52 12.15 1.32 15.66 11.77 1.48 14.74 11.37 1.67 13.74 10.93 1.88 12.63 10.45 2.12 62.0 (16.7) 17.07 15.40 1.18 16.26 15.01 1.32 15.44 14.60 1.49 14.58 14.14 1.67 13.76 13.32 1.88 12.79 12.79 2.12 57.0 (13.9) 16.50 16.50 1.18 15.86 15.86 1.32 15.19 15.19 1.49 14.47 14.47 1.67 13.67 13.67 1.88 12.77 12.77 2.12 72.0 (22.2) 21.04 11.10 1.17 20.03 10.73 1.32 18.96 10.35 1.48 17.83 9.94 1.67 16.59 9.50 1.89 15.23 9.03 2.13 67.0 (19.4) 19.10 13.87 1.18 18.17 13.49 1.33 17.20 13.10 1.50 16.17 12.69 1.68 15.05 12.24 1.90 13.81 11.75 2.14 600 63.0 (17.2)tt 17.71 13.31 1.19 16.84 12.93 1.34 15.94 12.54 1.50 14.99 12.13 1.69 13.95 11.68 1.90 12.80 11.18 2.14 62.0 (16.7) 17.47 16.50 1.19 16.65 16.06 1.34 15.88 15.44 1.50 15.04 15.04 1.69 14.18 14.18 1.90 13.22 13.22 2.14 57.0 (13.9) 17.19 17.19 1.20 16.50 16.50 1.34 15.79 15.79 1.50 15.02 15.02 1.69 14.16 14.16 1.90 13.20 13.20 2.14 72.0 (22.2) 21.34 11.60 1.19 20.29 11.22 1.34 19.19 10.84 1.50 18.02 10.43 1.69 16.74 9.98 1.91 15.35 9.50 2.15 67.0 (19.4) 19.38 14.68 1.20 18.41 14.29 1.35 17.42 13.89 1.51 16.35 13.47 1.70 15.20 13.00 1.92 13.95 12.48 2.16 675 63.0 (17.2)tt 17.98 14.06 1.21 17.06 13.66 1.36 16.16 13.27 1.52 15.17 12.84 1.71 14.10 12.38 1.92 12.93 11.85 2.16 62.0 (16.7) 18.01 16.88 1.21 17.22 16.30 1.36 16.30 16.30 1.52 15.48 15.48 1.71 14.58 14.58 1.92 13.56 13.56 2.16 57.0 (13.9) 17.76 17.76 1.21 17.03 17.03 1.36 225SAN02400A 16.28 Outdoor 16.28 1.52 15.46 15.46 1.71 14.56 14.56 1.92 13.55 13.55 2.16 72.0 22.2 28.31 14.39 1.54 27.03 13.91 1.72 25.65 13.40 1.93 24.16 12.86 2.16 22.53 12.28 2.43 20.76 11.66 2.74 67.0 (19.4) 25.74 17.76 1.55 24.54 17.27 1.74 23.27 16.75 1.95 21.90 16.19 2.19 20.41 15.60 2.46 18.77 14.95 2.77 700 63.0 17.2 tt 23.88 17.09 1.56 22.77 16.59 1.75 21.58 16.07 1.96 20.29 15.51 2.20 18.89 14.91 2.48 17.36 14.25 2.79 62.0 (16.7) 23.47 21.02 1.56 22.40 20.51 1.75 21.26 19.94 1.96 20.04 19.31 2.20 18.80 18.80 2.48 17.57 17.57 2.79 57.0 13.9 22.69 22.69 1.57 21.83 21.83 1.75 20.91 20.91 1.96 19.89 19.89 2.20 18.78 18.78 2.48 17.54 17.54 2.79 72.0 (22.2) 28.73 14.96 1.56 27.41 14.48 1.74 25.98 13.96 1.95 24.45 13.41 2.18 22.77 12.82 2.45 20.96 12.19 2.75 67.0 19.4 26.13 18.68 1.57 24.89 18.18 1.76 23.60 17.66 1.97 22.18 17.09 2.20 20.63 16.47 2.48 18.98 15.82 2.79 780 63.0 (17.2)tt 24.27 17.95 1.58 23.11 17.44 1.77 21.88 16.91 1.98 20.56 16.34 2.22 19.12 15.72 2.50 17.55 15.05 2.81 62.0 16.7 23.91 22.23 1.58 22.82 21.67 1.77 21.67 21.67 1.98 20.65 19.77 2.22 19.35 19.35 2.49 18.05 18.05 2.80 57.0 (13.9) 23.45 23.45 1.59 22.54 22.54 1.77 21.57 21.57 1.98 20.50 20.50 2.22 19.33 19.33 2.49 18.03 18.03 2.80 72.0 22.2 29.21 15.76 1.59 27.84 15.27 1.77 26.36 14.75 1.98 24.76 14.20 2.21 23.03 13.60 2.48 21.16 12.96 2.78 67.0 (19.4) 26.57 19.99 1.60 25.30 19.49 1.79 23.96 18.95 2.00 22.50 18.36 2.23 20.90 17.72 2.50 19.21 17.03 2.81 900 63.0 (17.2)tt 24.75 19.19 1.61 23.51 18.65 1.80 22.24 18.11 2.01 20.86 17.51 2.25 19.38 16.87 2.53 17.78 16.16 2.84 62.0 (16.7) 24.74 23.06 1.61 23.45 23.45 1.80 22.77 20.71 2.01 21.27 21.27 2.25 20.02 20.02 2.52 18.65 18.65 2.82 57.0 (13.9) 24.39 24.39 1.62 23.42 23.42 1.80 225SAN03000A 22.38 • • • 22.38 2.01 21.24 i 21.24 2.25 20.00 20.00 2.52 18.63 18.63 2.82 72.0 22.2 33.73 17.56 1.88 32.26 17.00 2.08 30.69 16.41 2.32 29.01• 15.78 2.59 27.19 15.11 2.89 25.19 14.39 3.24 67.0 (19.4) 30.54 21.64 1.87 29.19 21.08 2.08 27.76 20.48 2.31 26.23 19.85 2.58 24.56 19.18 2.88 22.74 18.43 3.23 875 63.0 17.2 tt 28.25 20.78 1.87 26.96 20.19 2.08 25.66 19.61 2.31 24.23 18.98 2.57 22.69 18.30 2.88 20.98 17.55 3.22 62.0 (16.7) 27.76 25.61 1.87 26.55 25.01 2.08 25.30 24.37 2.31 23.96 23.64 2.57 22.77 22.23 2.88 21.24 21.24 3.22 57.0 13.9 26.90 26.90 1.87 25.95 25.95 2.08 24.92 24.92 2.31 23.81 23.81 2.57 22.58 22.58 2.88 21.21 21.21 3.22 72.0 (22.2) 34.62 18.81 1.93 33.05 18.23 2.14 31.39 17.63 2.37 29.62 16.98 2.64 27.70 16.29 2.95 25.60 15.55 3.29 67.0 19.4 31.35 23.69 1.93 29.91 23.07 2.13 28.40 22.47 2.37 26.81 21.82 2.63 25.06 21.10 2.94 23.16 20.32 3.28 1055 63.0 (17.2)tt 29.00 22.65 1.93 27.67 22.06 2.13 26.27 21.44 2.36 24.77 20.79 2.63 23.06 20.18 2.93 21.39 19.27 3.27 62.0 16.7 28.70 28.17 1.93 27.79 26.62 2.13 26.32 26.32 2.36 25.10 25.10 2.63 23.75 23.75 2.93 22.25 22.25 3.28 57.0 (13.9) 28.47 28.47 1.93 27.41 27.41 2.13 26.29 26.29 2.36 25.06 25.06 2.63 23.72 23.72 2.93 22.22 22.22 3.28 72.0 22.2 34.88 19.27 1.95 33.28 18.68 2.16 31.59 18.07 2.39 29.79 17.42 2.66 27.84 16.73 2.97 25.71 15.98 3.31 67.0 (19.4) 31.58 24.42 1.95 30.13 23.81 2.15 28.60 23.18 2.39 26.97 22.55 2.65 25.21 21.79 2.96 23.29 21.01 3.30 1125 63.0 17.2 tt 29.23 23.34 1.95 27.88 22.75 2.15 26.45 22.12 2.38 24.93 21.47 2.65 23.29 20.72 2.95 21.51 19.90 3.30 62.0 (16.7) 29.35 28.17 1.95 28.20 27.21 2.15 26.76 26.76 2.38 25.50 25.50 2.65 24.11 24.11 2.95 22.57 22.57 3.30 57.0 13.9 28.98 28.98 1.95 27.89 27.89 2.15 26.73 26.73 2.38 25.47 25.47 2.65 24.08 24.08 2.95 22.55 22.55 3.30 DETAILED COOLING CAPACITIES# (Continued) EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75.0 (23.9) 85.0 (29.4) 95.0 (35.0) 105.0 (40.6) 115.0 (46.1) 125.0 (51.7) CFM EWB Capacity MBtuh Total Sys. KW** Capacity MBtuh I Total Sys. KW- .00• Capacity MBtuh Sys. Tota�ii I S ity MBtuh Total Sys. KW'* Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW" Total Sens$ Total Sens$ Total Outdoor Sens$ Sens$ Total Sens$ Total Sens$ 72.0 (22.2) 41.65 21.37 2.29 39.73 20.65 2.56 37.70 19.88 2.81 35.53 19.08 3.10 33.22 18.24 3.46 30.74 17.34 3.94 67.0 (19.4) 37.84 26.35 2.33 36.07 25.61 2.59 34.20 24.83 2.85 32.20 24.01 3.14 30.07 23.15 3.49 27.78 22.23 3.97 1060 63.0 (17.2)tt 35.05 25.33 2.34 33.41 24.59 2.61 31.65 23.80 2.87 29.77 22.97 3.15 27.75 22.05 3.50 25.63 21.17 3.96 62.0 (16.7) 34.43 31.15 2.34 32.85 30.37 2.61 31.16 29.52 2.87 29.40 28.59 3.15 27.78 26.91 3.50 25.87 25.87 3.96 57.0 (13.9) 33.21 33.21 2.34 31.95 31.95 2.61 30.59 30.59 2.87 29.12 29.12 3.15 27.54 27.54 3.50 25.83 25.83 3.96 72.0 (22.2) 42.35 22.32 2.33 40.36 21.58 2.59 38.26 20.80 2.84 36.01 19.99 3.13 33.63 19.14 3.50 31.06 18.23 3.98 67.0 (19.4) 38.52 27.88 2.36 36.73 27.17 2.63 34.73 26.33 2.89 32.65 25.53 3.17 30.46 24.62 3.53 28.11 23.67 4.01 1200 63.0 (17.2)tt 35.69 26.76 2.38 33.97 25.98 2.65 32.15 25.22 2.91 30.21 24.37 3.19 28.15 23.46 3.54 25.95 22.50 4.01 62.0 (16.7) 35.17 33.16 2.38 33.55 32.30 2.65 31.96 31.04 2.91 30.19 30.19 3.19 28.50 28.50 3.54 26.68 26.68 4.01 57.0 (13.9) 34.46 34.46 2.38 33.13 33.13 2.65 31.69 31.69 2.91 30.14 30.14 3.19 28.46 28.46 3.54 26.65 26.65 4.01 72.0 (22.2) 42.92 23.27 2.36 40.87 22.52 2.62 38.70 21.74 2.88 36.39 20.92 3.17 33.94 20.05 3.54 31.31 19.13 4.02 67.0 (19.4) 39.04 29.46 2.41 37.15 28.70 2.67 35.15 27.89 2.93 33.03 27.01 3.22 30.77 26.12 3.58 28.38 25.12 4.05 1350 63.0 (17.2)tt 36.22 28.22 2.42 34.43 27.45 2.69 32.38 26.55 2.95 30.58 25.76 3.23 28.47 24.83 3.59 26.23 23.82 4.06 62.0 (16.7) 35.86 35.05 2.42 34.24 34.24 2.69 32.73 32.73 2.95 31.07 31.07 3.23 29.31 29.31 3.59 27.40 27.40 4.06 57.0 (13.9) 35.60 35.60 2.43 34.18 34.18 2.69 0• 32.67 00• Outdoor 32.67 2.95 31.03 31.03 3.23 29.28 29.28 3.59 27.37 27.37 4.06 72.0 (22.2) 48.60 25.34 2.78 46.33 24.47 3.05 43.92 23.55 3.35 41.35 22.59 3.69 38.56 21.56 4.08 35.57 20.47 4.51 67.0 19.4 44.20 31.29 2.76 42.16 30.41 3.03 40.00 29.52 3.33 37.66 28.55 3.68 35.14 27.51 4.06 32.42 26.39 4.50 1240 63.0 (17.2)tt 41.02 30.12 2.75 39.13 29.25 3.02 37.13 28.33 3.32 34.97 27.38 3.66 32.64 26.34 4.05 30.10 25.20 4.49 62.0 16.7 40.34 37.05 2.75 38.51 36.14 3.02 36.60 35.16 3.32 34.57 34.05 3.66 32.61 32.17 4.05 30.38 30.38 4.49 57.0 (13.9) 38.95 38.95 2.74 37.50 37.50 3.01 35.95 35.95 3.32 34.26 34.26 3.66 32.39 32.39 4.05 30.33 30.33 4.49 72.0 22.2 49.37 26.42 2.83 47.01 25.53 3.10 44.51 24.60 3.40 41.83 23.62 3.74 38.96 22.57 4.13 35.87 21.47 4.56 67.0 (19.4) 44.94 33.07 2.81 42.80 32.18 3.08 40.60 31.27 3.38 38.15 30.26 3.73 35.54 29.19 4.11 32.74 28.03 4.55 1400 63.0 17.2 tt 41.72 31.77 2.80 39.75 30.88 3.07 37.67 29.95 3.37 35.43 28.96 3.71 33.03 27.90 4.10 30.43 26.73 4.54 62.0 (16.7) 41.00 39.25 2.80 39.28 38.36 3.07 37.60 36.44 3.37 35.39 35.39 3.71 33.41 33.41 4.10 31.22 31.22 4.54 57.0 13.9 40.36 40.36 2.80 38.81 38.81 3.07 37.15 37.15 3.37 35.34 35.34 3.71 33.37 33.37 4.10 31.19 31.19 4.54 72.0 (22.2) 50.01 27.54 2.88 47.56 26.63 3.15 44.97 25.69 3.46 42.22 24.69 3.80 39.26 23.63 4.18 36.09 22.51 4.61 67.0 19.4 45.54 34.92 2.87 43.33 34.01 3.14 41.02 33.06 3.44 38.53 32.03 3.78 35.87 30.93 4.17 33.00 29.72 4.60 1575 63.0 (17.2)tt 42.31 33.47 2.85 40.28 32.57 3.12 38.12 31.59 3.43 35.82 30.60 3.77 33.37 29.48 4.16 30.70 28.27 4.59 62.0 (16.7) 41.94 41.55 2.85 40.30 39.64 3.12 38.33 38.33 3.43 36.38 36.38 3.77 34.28 34.28 4.16 31.98 31.98 4.60 57.0 (13.9) 41.64 41.64 2.85 39.99 39.99 3.12 0.•00• 38.25 Outdoor 38.25 3.43 36.34 36.34 3.77 34.24 34.24 4.16 31.94 31.94 4.60 72.0 (22.2) 55.87 29.05 3.15 53.35 28.08 3.48 50.68 27.07 3.86 47.80 25.99 4.28 44.69 24.83 4.76 41.32 23.59 5.29 67.0 19.4 50.74 35.74 3.13 48.44 34.76 3.46 46.00 33.74 3.83 43.37 32.65 4.26 40.53 31.47 4.73 37.44 30.21 5.26 1390 63.0 (17.2)tt 47.01 34.36 3.12 44.90 33.40 3.44 42.63 32.38 3.82 40.19 31.29 4.24 37.55 30.11 4.71 34.66 28.84 5.24 62.0 16.7 46.17 42.21 3.11 44.12 41.22 3.44 41.95 40.14 3.81 39.64 38.93 4.24 37.50 36.67 4.71 34.86 34.86 5.24 57.0 (13.9) 44.48 44.48 3.11 42.87 42.87 3.44 41.13 41.13 3.81 39.23 39.23 4.23 37.13 37.13 4.71 34.81 34.81 5.24 72.0 22.2 56.99 30.56 3.21 54.35 29.56 3.55 51.56 28.52 3.92 48.55 27.43 4.35 45.33 26.24 4.83 41.84 24.99 5.36 67.0 (19.4) 51.78 38.17 3.19 49.37 37.17 3.52 46.82 36.12 3.90 44.08 35.00 4.32 41.13 33.79 4.80 37.95 32.49 5.33 1600 63.0 17.2 tt 48.01 36.63 3.18 45.82 35.65 3.51 43.42 34.59 3.88 40.88 33.47 4.30 38.13 32.24 4.78 35.16 30.94 5.31 62.0 (16.7) 47.29 45.42 3.18 45.22 44.28 3.51 43.24 42.39 3.88 40.84 40.84 4.30 38.59 38.59 4.78 36.10 36.10 5.31 57.0 13.9 46.44 46.44 3.18 44.70 44.70 3.50 42.83 42.83 3.88 40.79 40.79 4.30 38.54 38.54 4.78 36.06 36.06 5.31 72.0 (22.2) 57.79 31.89 3.27 55.06 30.89 3.61 52.17 29.83 3.98 49.08 28.72 4.41 45.76 27.53 4.89 42.17 26.26 5.42 67.0 19.4 52.53 40.36 3.25 50.03 39.35 3.58 47.40 38.28 3.96 44.59 37.12 4.38 41.55 35.87 4.86 38.31 34.52 5.39 1800 63.0 (17.2)tt 48.72 38.67 3.24 46.43 37.63 3.57 43.99 36.58 3.94 41.37 35.40 4.36 38.58 34.17 4.84 35.52 32.79 5.37 62.0 16.7 48.29 48.07 3.24 46.68 45.27 3.57 44.21 44.21 3.94 42.05 42.05 4.37 39.67 39.67 4.85 37.07 37.07 5.38 57.0 (13.9) 47.99 47.99 3.24 46.14 46.14 3.57 44.16 44.16 3.94 42.00 42.00 4.37 39.63 39.63 4.85 37.02 37.02 5.38 DETAILED COOLING CAPACITIES# (Continued) EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75.0 (23.9) 85.0 (29.4) 95.0 (35.0) 105.0 (40.6) 115.0 (46.1) 125.0 (51.7) CFM EWB Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW- Capacity MBtuh Sys. Tota�ii I S ity MBtuh Total Sys. KW'* Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW" Total Sens$ Total Sens$ Total Outdoor Sens$ Sens$ Total Sens$ Total Sens$ 72.0 (22.2) 69.21 35.68 3.92 66.03 34.48 4.31 62.63 33.22 4.77 58.98 31.87 5.29 55.00 30.43 5.89 50.73 28.90 6.55 67.0 (19.4) 62.99 44.15 3.91 60.07 42.92 4.30 57.00 41.66 4.75 53.67 40.30 5.27 50.05 38.84 5.86 46.13 37.27 6.53 1735 63.0 (17.2)tt 58.43 42.45 3.90 55.76 41.25 4.28 52.91 40.00 4.73 49.85 38.64 5.25 46.50 37.19 5.84 42.85 35.62 6.51 62.0 (16.7) 57.37 52.31 3.90 54.80 51.06 4.28 52.09 49.70 4.73 49.36 47.68 5.25 46.28 46.28 5.84 43.28 43.28 6.51 57.0 (13.9) 55.54 55.54 3.89 53.50 53.50 4.27 51.30 51.30 4.73 48.88 48.88 5.25 46.20 46.20 5.84 43.22 43.22 6.51 72.0 (22.2) 70.52 37.55 4.00 67.19 36.32 4.40 63.64 35.03 4.85 59.83 33.66 5.38 55.71 32.20 5.98 51.29 30.64 6.64 67.0 (19.4) 64.19 47.18 3.99 61.17 45.94 4.38 57.94 44.65 4.84 54.48 43.24 5.36 50.73 41.74 5.95 46.68 40.11 6.62 2000 63.0 (17.2)tt 59.61 45.29 3.98 56.81 44.07 4.37 53.84 42.78 4.82 50.65 41.37 5.34 47.16 39.87 5.93 43.39 38.24 6.59 62.0 (16.7) 58.76 56.28 3.98 56.13 54.83 4.37 53.44 53.44 4.82 50.82 50.82 5.34 47.92 47.92 5.94 44.75 44.75 6.60 57.0 (13.9) 57.95 57.95 3.98 55.74 55.74 4.37 53.36 53.36 4.82 50.75 50.75 5.34 47.87 47.87 5.94 44.69 44.69 6.60 72.0 (22.2) 71.43 39.21 4.08 67.99 37.97 4.47 64.32 36.66 4.93 60.40 35.27 5.46 56.16 33.79 6.06 51.64 32.22 6.72 67.0 (19.4) 65.05 49.92 4.07 61.91 48.66 4.46 58.63 47.34 4.92 55.03 45.88 5.44 51.19 44.33 6.03 47.06 42.63 6.70 2250 63.0 (17.2)tt 60.45 47.82 4.06 57.55 46.58 4.45 54.50 45.24 4.90 51.19 43.81 5.42 47.62 42.24 6.01 43.78 40.51 6.68 62.0 (16.7) 59.93 59.93 4.06 57.98 55.94 4.45 55.01 55.01 4.90 52.24 52.24 5.43 49.20 49.20 6.02 45.85 45.85 6.69 57.0 (13.9) 59.82 59.82 4.06 57.47 57.47 4.45 54.95 54.95 4.90 52.18 52.18 5.43 49.15 49.15 6.02 45.80 45.80 6.69 ra #Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. fD $Sensible capacities shown are based on 80°F (27 °C) entering air at the indoor coil. For sensible capacities at other than 80°F (27C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80 °F (27°C). 3 "Total System. kw is total of indoor and outdoor unit kilowatts. ttAt TVA rating indoor condition (75°F edb/63 °F ewb). All other indoor air temperatures are at 80°F edb. NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. m EWB Entering Wet Bulb HEAT PUMP HEATING PERFORMANCE OUTDOOR COIL ENTERING AIR TEMPERATURES "F ("C) INDOOR AIR .3.0 (-19.4) 7.0 (-13.9) 17.0 (-8.3) 27.0 (-2.8) 37.0 (2.8) 47.0 (8.3) 57.0 (13.9) 67.0 (19.4) EDB CFM Capacity MBtuh Total Sys. K1Nt Capacity MBtuh Total Sys. KWt Capacity MBtuh Total Sys. KWt :00• Outdoor Capacity MBtuh Total Sys. KWt Capacity MBtuh Total Sys. KWt Capacity Total Sys. KWt Capacity Total Sys. KWt Capacity Total Sys. KWt Integ* Total Integ* Total Integ* Total Integ* Total Integ* Total Total Integ* Total Total Integ* Total Total Integ* 525 6.31 5.80 1.06 8.24 7.57 1.12 10.33 9.42 1.18 12.82 11.39 1.25 14.99 13.64 1.32 17.43 17.43 1.39 19.89 19.89 1.46 22.25 22.25 1.53 65.0 (18.3) 600 6.44 5.92 1.07 8.39 7.71 1.13 10.49 9.57 1.18 12.98 11.53 1.24 15.17 13.81 1.30 17.65 17.65 1.37 20.05 20.05 1.42 22.35 22.35 1.49 675 6.56 6.03 1.09 8.52 7.83 1.14 10.64 9.70 1.19 13.11 11.65 1.24 15.33 13.95 1.29 17.84 17.84 1.35 20.16 20.16 1.40 22.39 22.39 1.46 525 5.98 5.50 1.11 7.94 7.30 1.17 10.04 9.15 1.24 12.60 11.19 1.31 14.79 13.46 1.38 17.18 17.18 1.46 19.51 19.51 1.53 21.99 21.99 1.61 70.0 (21.1) 600 6.10 5.61 1.12 8.08 7.42 1.18 10.20 9.30 1.24 12.76 11.33 1.30 14.96 13.61 1.36 17.40 17.40 1.43 19.80 19.80 1.50 22.01 22.01 1.57 675 6.21 5.71 1.13 8.21 7.54 1.18 10.34 9.43 1.24 12.90 11.46 1.30 15.11 13.75 1.35 17.59 17.59 1.42 19.93 19.93 1.47 22.16 22.16 1.53 525 5.66 5.21 1.15 7.64 7.02 1.22 9.76 8.90 1.29 12.12 10.77 1.36 14.59 13.28 1.45 16.93 16.93 1.53 19.52 19.52 1.61 21.74 21.74 1.69 75.0 (23.9) 600 5.77 5.31 1.16 7.78 7.15 1.23 9.91 9.04 1.29 12.36 10.98 1.36 14.75 13.42 1.43 17.15 17.15 1.50 19.69 19.69 1.57 21.85 21.85 1.64 675 5.88 5.41 1.18 7.90 7.26 1.24 10.05 9.16 1.29 •00• Outdoor 12.68 11.26 1.36 14.90 13.56 1.42 17.33 17.33 1.49 19.79 19.79 1.55 21.89 21.89 1.61 700 9.25 8.51 1.46 11.80 10.84 1.51 14.65 13.36 1.57 17.55 15.59 1.64 20.48 18.64 1.70 23.72 23.72 1.76 26.48 26.48 1.81 29.22 29.22 1.87 65.0 (18.3) 780 9.37 8.62 1.47 11.95 10.98 1.51 15.04 13.71 1.58 17.71 15.73 1.62 20.68 18.82 1.68 23.86 23.86 1.73 26.51 26.51 1.78 29.14 29.14 1.83 900 9.54 8.77 1.49 12.15 11.16 1.52 15.24 13.90 1.58 17.92 15.92 1.62 20.93 19.05 1.67 23.93 23.93 1.71 26.50 26.50 1.75 28.95 28.95 1.79 700 8.92 8.20 1.52 11.47 10.54 1.58 14.22 12.97 1.64 17.33 15.39 1.72 20.20 18.38 1.78 23.45 23.45 1.85 26.22 26.22 1.90 28.63 28.63 1.96 70.0 (21.1) 780 9.04 8.31 1.54 11.62 10.68 1.58 14.40 13.13 1.64 17.48 15.53 1.71 20.40 18.56 1.76 23.60 23.60 1.82 26.26 26.26 1.87 28.88 28.88 1.92 900 9.21 8.47 1.55 11.81 10.85 1.59 14.66 13.37 1.64 17.69 15.71 1.70 20.65 18.79 1.75 23.86 23.86 1.79 26.27 26.27 1.83 28.80 28.80 1.87 700 8.57 7.88 1.59 11.12 10.22 1.65 13.86 12.64 1.71 17.09 15.18 1.81 19.92 18.13 1.87 23.12 23.12 1.95 25.95 25.95 2.00 28.41 28.41 2.05 75.0 (23.9) 780 8.69 7.99 1.60 11.27 10.36 1.65 14.03 12.79 1.71 17.25 15.32 1.79 20.11 18.30 1.85 23.32 23.32 1.92 26.00 26.00 1.96 28.60 28.60 2.01 900 8.86 8.15 1.62 11.47 10.54 1.67 14.26 13.00 225SAN03000A 1.72 Outdoor 17.45 Section 15.50 With 1.78 FJ4DNXB30L* 20.36 Indoor 18.53 Section 1.84 23.49 23.49 1.88 26.03 26.03 1.93 28.48 28.48 1.97 875 10.57 9.72 1.64 13.85 12.73 1.72 17.28 15.76 1.79 21.23 18.86 1.89 24.67 22.45 1.96 28.51 28.51 2.04 32.89 32.89 2.15 38.06 38.06 2.28 65.0 (18.3) 1055 10.85 9.98 1.67 14.18 13.03 1.74 17.66 16.10 1.81 21.56 19.15 1.88 25.07 22.81 1.94 29.01 29.01 2.01 33.55 33.55 2.11 38.62 38.62 2.20 1125 10.95 10.07 1.68 14.29 13.13 1.75 17.79 16.22 1.81 21.68 19.26 1.89 25.21 22.94 1.94 29.17 29.17 2.01 33.76 33.76 2.10 38.73 38.73 2.19 875 10.08 9.27 1.70 13.39 12.30 1.79 16.83 15.35 1.87 20.92 18.58 1.97 24.34 22.15 2.05 28.12 28.12 2.14 32.38 32.38 2.25 37.46 37.46 2.39 70.0 (21.1) 1055 10.37 9.54 1.73 13.72 12.61 1.81 17.20 15.68 1.88 21.26 18.89 1.97 24.73 22.50 2.03 28.60 28.60 2.11 33.02 33.02 2.20 38.12 38.12 2.30 1125 10.47 9.63 1.75 13.83 12.71 1.82 17.33 15.80 1.89 21.39 19.00 1.97 24.86 22.62 2.03 28.76 28.76 2.10 33.23 33.23 2.20 38.25 38.25 2.29 875 9.59 8.82 1.76 12.92 11.87 1.86 16.38 14.94 1.95 20.21 17.95 2.04 24.00 21.84 2.14 27.72 27.72 2.24 31.88 31.88 2.35 36.84 36.84 2.51 75.0 (23.9) 1055 9.87 9.08 1.80 13.24 12.17 1.88 16.75 15.27 1.96 20.93 18.59 2.05 24.39 22.20 2.12 28.20 28.20 2.20 32.50 32.50 2.30 37.59 37.59 2.41 1125 9.96 9.16 1.81 13.35 12.27 1.89 16.87 15.38 1.97 .00• Outdoor 121.05 18.70 2.06 24.52 .30.04 Indoor 22.31 Section 2.12 28.36 28.36 2.20 32.70 32.70 2.30 37.75 37.75 2.39 1060 13.57 12.48 2.18 17.01 15.63 2.19 21.01 19.16 2.26 25.84 22.95 2.39 27.34 2.49 34.58 34.58 2.60 39.39 39.39 2.69 44.72 44.72 2.78 65.0 (18.3) 1200 13.82 12.71 2.20 17.30 15.90 2.20 21.35 19.47 2.27 26.14 23.22 2.38 30.41 27.67 2.48 35.06 35.06 2.58 39.98 39.98 2.67 45.47 45.47 2.74 1350 14.06 12.93 2.23 17.57 16.14 2.22 21.65 19.74 2.28 26.43 23.48 2.39 30.76 27.99 2.48 35.49 35.49 2.57 40.51 40.51 2.65 46.11 46.11 2.71 1060 12.97 11.93 2.28 16.42 15.09 2.29 20.40 18.60 2.35 25.37 22.54 2.48 29.53 26.87 2.59 34.00 34.00 2.69 38.63 38.63 2.79 43.93 43.93 2.89 70.0 (21.1) 1200 13.24 12.18 2.31 16.72 15.36 2.31 20.74 18.91 2.37 25.71 22.84 2.48 29.91 27.22 2.58 34.47 34.47 2.68 39.26 39.26 2.76 44.65 44.65 2.85 1350 13.47 12.39 2.34 16.99 15.61 2.33 21.06 19.20 2.39 26.01 23.10 2.49 30.27 27.55 2.58 34.90 34.90 2.67 39.81 39.81 2.75 45.29 45.29 2.82 1060 12.31 11.32 2.36 15.76 14.48 2.37 19.74 18.00 2.44 24.24 21.53 2.55 29.02 26.41 2.68 33.42 33.42 2.79 37.92 37.92 2.90 43.17 43.17 3.01 75.0 (23.9) 1200 12.56 11.55 2.39 16.05 14.75 2.39 20.08 18.31 1 2.45 124.77 1 22.00 1 2.56 129.40 1 26.75 1 2.67 33.88 33.88 2.78 38.68 38.68 2.88 43.86 43.86 2.96 1350 12.81 11.78 2.43 16.34 15.01 2.42 20.40 18.60 2.47 0• 00• Outdoor 25.51 Section 22.66 With 2.59 FJ4DNXC42L' 29.74 Indoor 27.06 Section 2.68 34.30 34.30 2.77 39.06 39.06 2.86 44.47 44.47 2.93 1240 16.99 15.63 2.54 21.52 19.77 2.66 26.48 24.15 2.78 31.94 28.37 2.92 36.98 33.65 3.05 42.60 42.60 3.19 48.96 48.96 3.38 55.33 55.33 3.53 65.0 (18.3) 1400 17.30 15.91 2.57 21.85 20.08 2.68 26.93 24.56 2.79 32.29 28.68 2.92 37.43 34.06 3.03 43.09 43.09 3.16 49.58 49.58 3.32 55.68M55.393.57 .47 1575 17.60 16.19 2.61 22.18 20.38 2.70 27.39 24.98 2.81 32.63 28.99 2.92 37.82 34.42 3.03 43.57 43.57 3.15 50.05 50.05 3.29 56.08.43 1240 16.32 15.01 2.64 20.86 19.17 2.76 25.80 23.53 2.89 31.50 27.98 3.05 36.49 33.21 3.17 42.00 42.00 3.33 48.21 48.21 3.52 54.61.68 70.0 (21.1) 1400 16.61 15.28 2.67 21.21 19.49 2.78 26.19 23.88 2.90 31.84 28.28 3.04 36.90 33.58 3.16 42.66 42.66 3.30 48.84 48.84 3.46 55.06.61 1575 16.91 15.55 2.70 21.53 19.78 2.80 26.56 24.22 2.91 32.19 28.59 3.05 37.29 33.93 3.15 42.96 42.96 3.28 49.37 49.37 3.42 55.39.571240 15.58 14.33 2.73 20.17 18.53 2.86 25.12 22.91 3.00 31.06 27.59 3.18 35.99 32.75 3.31 41.41 41.41 3.47 47.45 47.45 3.67 53.91.831400 15.88 14.60 2.76 20.52 18.85 2.88 25.50 23.25 3.01 31.40 27.89 3.17 36.38 33.11 3.29 41.89 41.89 3.43 48.08 48.08 3.61 54.36.761575 16.17 14.87 2.80 20.84 19.15 2.91 25.86 23.58 3.02 31.74 28.19 3.17 36.63 33.33 3.28 42.35 42.35 3.42 48.64 48.64 3.57 54.67.72 HEAT PUMP HEATING PERFORMANCE (Continued) OUTDOOR COIL ENTERING AIR TEMPERATURES °F (°C) INDOOR AIR .3.0 (-19.4) 7.0 (-13.9) 17.0 (-8.3) 27.0 (-2.8) 37.0 (2.8) 47.0 (8.3) 57.0 (13.9) 67.0 (19.4) EDB CFM Capacity MBtuh Total Sys. KWtt Capacity MBtuh Total Sys. Capacity MBtuh Total Sys' KWt :00• Outdoor Capacity MBtuh Total Sys. I(1Nt Capacity MBtuh Total Sys. KWt Capacity MBtuh Total Sys. KWt Capacity MBtuh Total Sys. KWt Capacity MBtuh Total Sys. KWt Total Integ* Total Integ* Total Integ* Total Integ* Total Indoor Integ* Section Total Integ* Total Integ* Total I Integ* 1390 19.57 18.00 2.85 24.39 22.41 2.96 29.74 27.12 3.07 35.56 31.59 3.20 41.01 3.31 47.17 47.17 1 .45 54.37 54.37 3.63 62.01 62.01 3.78 65.0 (18.3) 1600 19.94 18.34 2.88 24.80 22.79 2.97 30.31 27.64 3.08 35.98 31.96 3.19 41.51 37.78 3.29 47.81 47.81 3.41 55.19 55.19 3.56 62.47 62.47 3.68 1800 20.25 18.62 2.91 25.15 23.11 3.00 31.02 28.29 3.11 36.32 32.26 3.20 41.92 38.15 3.28 48.32 48.32 3.39 55.75 55.75 3.51 62.68 62.68 3.63 1390 18.83 17.32 2.96 23.72 21.79 3.08 29.00 26.44 3.19 35.11 31.19 3.35 40.48 36.84 3.46 46.50 46.50 3.61 53.55 53.55 3.79 61.23 61.23 3.95 70.0 (21.1) 1600 19.20 17.66 2.99 24.11 22.15 3.10 29.46 26.86 3.20 35.51 31.54 3.34 40.96 37.27 3.44 47.13 47.13 3.56 54.36 54.36 3.73 61.68 61.68 3.85 1800 19.51 17.94 3.03 24.45 22.47 3.12 29.87 27.24 3.22 35.87 31.86 3.34 41.37 37.65 3.43 47.63 47.63 3.54 54.97 54.97 3.67 61.95 61.95 3.79 1390 18.07 16.62 3.08 23.00 21.13 3.20 28.29 25.80 3.33 34.68 30.81 3.50 39.98 36.38 3.62 45.84 45.84 3.77 52.73 52.73 3.96 60.36 60.36 4.12 75.0 (23.9) 1 1600 1.43 16.95 3.11 23.40 21.50 3.22 28.75 26.22 3.34 35.07 31.15 3.49 40.45 36.81 3.59 46.45 46.45 3.72 53.53 53.53 3.89 60.89 60.89 4.02 1800 188.74 17.23 3.14 23.74 21.81 3.25 29.13 26.56 3.35 Outdoor 35.43 Section 31.47 With 3.49 FJ4DNXD60L* 40.85 Indoor225SAN06000A 37.17 Section 3.58 46.95 46.95 3.70 54.15 54.15 3.84 61.18 61.18 3.96 1735 24.41 22.45 3.46 30.46 27.99 3.55 36.84 33.59 3.66 43.94 39.03 3.80 51.13 46.53 3.97 57.77 57.77 4.12 65.361 5.36 4.31 73.43 73.43 4.46 65.0 (18.3) 2000 24.94 22.94 3.51 31.05 28.53 3.59 37.49 34.18 3.68 45.49 40.41 3.84 51.78 47.12 3.95 58.57 58.57 4.09 66.39 66.39 4.25 74.12M73.654.51 .37 2250 25.38 23.34 3.57 31.53 28.97 3.63 38.04 34.69 3.72 45.99 40.85 3.86 52.40 47.69 3.96 59.21 59.21 4.08 67.22 67.22 4.22 74.60.32 1735 23.25 21.38 3.59 29.39 27.00 3.68 35.80 32.64 3.80 42.69 37.92 3.95 50.48 45.94 4.14 57.00 57.00 4.31 64.36 64.36 4.50 72.44.66 70.0 (21.1) 2000 23.77 21.86 3.64 29.96 27.53 3.72 36.45 33.24 3.83 43.52 38.66 3.96 51.26 46.65 4.13 57.74 57.74 4.26 65.36 65.36 4.44 73.17.56 2250 24.21 22.27 3.70 30.44 27.97 3.77 36.98 33.72 3.86 44.15 39.22 3.98 51.61 46.97 4.13 58.36 58.36 4.25 66.17 66.17 4.40 73.65.511735 22.05 20.28 3.72 28.28 25.98 3.82 34.75 31.69 3.95 41.62 36.97 4.11 49.79 45.31 4.33 56.23 56.23 4.50 63.37 63.37 4.70 71.41.8775.0(23.9) 2000 22.56 20.75 3.77 28.85 26.51 3.86 35.38 32.26 3.98 42.37 37.64 4.11 50.41 45.87 4.31 56.98 56.98 4.45 64.35 64.35 4.63 72.18.762250 22.99 21.14 3.83 29.32 26.94 3. 11 35.92 32.75 4.01 42.96 38.16 4.13 50.91 46.33 4.31 57.48 57.48 4.44 65.12 65.12 4.60 72.65.70 NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. * The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total Sys. capacity. t The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total Sys. kilowatts. EDB Entering Dry Bulb2 225S: Product Data Guide Specifications General System Description Outdoor -mounted, air-cooled, split -system heat pump unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller -type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit. Quality Assurance — Unit will be rated in accordance with the latest edition of AHRI Standard 210/240. — Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory. — Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have C-UL approval. — Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500-hr salt spray test. — Air-cooled condenser coils are pressure tested and the outdoor unit is leak tested. — Unit constructed in IS09001 approved facility. Delivery, Storage, and Handling Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations. Warranty (for inclusion by specifying engineer) U.S. and Canada only. PRODUCTS Equipment Factory assembled, single piece, air-cooled heat pump unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puron®, and special features required prior to field start-up. Unit Cabinet Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint. Available with louvered coil guard only. Fans Condenser fan will be direct -drive propeller type, discharging air upward. Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. Fan blades will be statically and dynamically balanced. Condenser fan openings will be equipped with steel wire safety guards. Compressor Compressor will be hermetically sealed. Compressor will be mounted on rubber vibration isolators. Condenser Coil Condenser coil will be air cooled. Coil will be constructed of aluminum fins mechanically bonded to copper or aluminum tubes which are then cleaned, dehydrated, and sealed. Air -Cooled, Split -System Heat Pump 225S 1-1 /2 to 5 nominal tons Refrigeration Components Refrigeration circuit components will include liquid -line shutoff valve with sweat connections, vapor -line shutoff valve with sweat connections, system charge of Puron® refrigerant, POE compressor oil, accumulator, and reversing valve. Operating Characteristics The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power consumption at full load will not exceed kW. Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at conditions of CFM entering air temperature at the evaporator at °F wet bulb and °F/°C dry bulb, and air entering the unit at °F/°C. The system will have a SEER of Btuh/watt or greater at DOE conditions. Electrical Requirements Nominal unit electrical characteristics will be v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v to V. Unit electrical power will be single point connection. Control circuit will be 24v. Special Features Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 17 225S: Product Data System Design Summary 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operating air temperature without low -ambient operation accessory is 55°F (12.8°C). 3. Maximum outdoor operating air temperature for cooling mode is 125°F (51.7°C). 4. Minimum outdoor operating air temperature for heating mode is —10°F (-23.3 ° C). 5. Maximum outdoor operating air temperature for heating mode is 66°F (18.9°C). 6. For reliable operation, unit should be level in all horizontal planes. 7. For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or elevation differences between indoor and outdoor units greater than 20 ft (6.1 m), consult Residential Piping and Longline Guideline and Service Manual available from equipment distributor. 8. If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4 mm). 9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 10. Do not apply capillary tube indoor coils to these units. 11. Factory -supplied filter drier must be installed © 2022 Carrier. All rights reserved. A Carrier Company Edition Date: 09/22 Catalog No: PDS225S-01 Replaces: New Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 18