Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2023-1549_Structural_Calculations_12.4.2023_3.50.28_PM_3933062
Ghe— Solar Project (41263o93) pitched root /lr IRONRIDGE 28357 INDUSTRIAL BLVD., HAMARD, CA 94545 Project Details Name Location Module Dimensions ASCE Ghenov Solar Project 8909 217th Street Southwest, Edmonds, WA 98026 REC Solar: REC410AA Pure 2 (30mm) Dimensions: 73.39" x 40.87" x 1.18" (1864.Omm x 1038.Omm x 30.Omm) 7-10 r ► 4 Ok System Weight Total system weight Weightlattachment Racking weight Distributed weight Roof Information Roof Material Family Risk category Attachment hardware Specific gravity Comp Shingle 11 Square 0.42 Load Assumptions 985.5 Ibs Wind exposure 30.8 Ibs Wind speed 128.3 Ibs Ground snow load 2.6 psf Attachment spacing portrait Roof material Roof attachment Staggered attachments Date Total modules Total watts Attachments Rails per row Comp Shingle Halo UltraGrip (Rafter attached) No 12/04/2023 18 7,380 32 2 B 110 mph 15 psf 4.0' Last Undated by Madison Martinez on 1210423 03:43 PM Page 1018 Ghe— Solar Project (412-93) pitched root /lr IRONRIDGE 28357 INDUSTRIAL BLVD., HAMARD, CA 94545 Roof Plane A Height 30 ft Roof Plane A: Roof Section 1 Details Panels: 18 Rail orientation: East-West Panel orientation: Portrait Entry type: Graphical Diagram Slope 11 ° Provided rail: 140' [4 x 84", 8 x 168"] Attachments: 32 Splices: 8 Clamps: 40 Rafter spacing Weights Total weight: 985.5 Ibs Weight/attachment: 30.8 l b s Total Area: 381.0 sq ft Distributed weight: 2.6 psf 24 in Segments Identifier Columns Row length Rail length Cantilever Rail Attachments Splices Clamps A 9 31' 1" 31' 1" 1' 6" 70' [2 x 84", 4 x 168"] 16 4 20 Row segment totals (x 2) 140' [4 x 84", 8 x 168"] 32 8 40 Last Undated by Madison Martinez on 1210423 03:43 PM Page L of 8 Ghenw Solar Project pitched root /lr IRONRIDGE 28357 INDUSTRIAL BLVD., HAMARD, CA 94545 Span Details XR100 - Portrait Zone Max span Max cantilever 1 8' 3' 2 8' 3' 3 7' 11" 3' Reaction Forces XR100 - Portrait Uplift Zone Down Uplift Lateral Par (ibs) Lateral (PSF) (Ibs) (Ibs) Perp (Ibs) 1 9.8 247 97 45 18 2 18.1 247 204 45 18 3 28.0 247 326 45 18 Attachment Span Details Halo UltraGrip (Rafter attached) - Portrait Zone 1 2 3 Max attachment span 8' 8' 7' 11" *Optional - Attachment Span Details Halo UltraGrip (Deck attached) - Portrait Zone Max attachment span 1 3' 7" 2 3' 7" 3 2' 4" * Based on minimum 7116" sheathing thickness Last Undated by Madison Martinez on 1210423 03:43 PM Page 3 U18 Ghe— Solar Project (41263093) pitched root /lr IRONRIDGE 28357 INDUSTRIAL BLVD., HAMARD, CA 94545 Side View (portrait) Front View (portrait) I1TI IIIIDI M �l f:7:�lil LO ULTRAGRIP (HUG) TRAGRIP kSHING TECHNOLOGY STRUCTURAL SCREW FTER 4.0' ATTACHMENT SPAN Last undated by Madison Martinez on 1210423 03:43 PM Page 4 of 8 Ghe— Solar Project (4126 93) pitched root Front View (portrait) /lr IRONRIDGE 28357 INDUSTRIAL BLVD., HAMARD, CA 94545 Splice Details TOP -FACING SLOT Clamp Detail PV MODULE FRAME UNIVERSAL FASTENING OBJECT Mid Clamp, Plan PV MODULE XR RAIL HALO ULTRAGRIP (HUG) ULTRAGRIP FLASHING TECHNOLOGY RD STRUCTURAL SCREW RAFTER XR100 RAIL SPLICE r _ BONDING SPRING --�XR100 INTERNAL SPLICE QG SLOT Splice Connection Mid Clamp, Front UNIVERSAL FASTENING OBJECT PV MODULE FRAME RAIL End Clamp, Plan RAIL PV MODULE FRAME UNIVERSAL FASTENING OBJECT STOPPER SLEEVE End Clamp, Front STOPPER SLEEVE UNIVERSAL FASTENING OBJECT RAIL PV MODULE FRAME Last undated by Madison Martinez on 1210423 03:43 PM Page 5 018 Ghe— Solar Project (K1263093) pitched root /lr IRONRIDGE 28357 INDUSTRIAL BLVD., HAMARD, CA 94545 Plan View Side View Perspective View Front View Last undated by Madison Martinez on 1210423 03:43 PM Page 6 of 8 Ghenw Solar Project �o�asac�3� pitched root /lr IRONRIDGE 28357 INDUSTRIAL BLVD., HAMARD, CA 94545 Grounding Diagram reFiN rwiwl OUFO Clamp --+ Fault Current Ground Path 0X • Grounding Lug * Min 10 AWG Copper Wire m Bonded Splice (Rail Connection) * Grounding Lugs and Wire are not required in systems using Enphase microinverters. Last Undated by Madison Martinez on 1210423 03:43 PM Page 7 018 Ghenov solar Project (4126aoe3) AM& I RONRIDGE pitchetl root 28357 INDUSTRIAL BLVD., HAMARD, CA 94545 Bill of Materials Part Rails & Splices XR-100-168B XR100, Rail 168" Black * 2 x 168" rail to be cut on -site into 84" sections. XR100-BOSS-01-M1 Bonded Splice, XR100 Clamps & Grounding UFO-CL-01-B1 Universal Module Clamp, Black UFO-STP-30MM-B1 Stopper Sleeve, 30MM, Black XR-LUG-03-Al Grounding Lug, Low Profile Attachments QM-HUG-01-B1 Halo UltraGrip, Black HW-RD1430-01-M1 RD Structural Screw, 3.01 *Add desired additional screws by adjusting spares column. BHW-SQ-02-Al Square -Bolt Bonding Hardware Spares Total Qty 0 10 0 8 0 40 0 8 0 2 0 32 0 64 0 32 Last Undated by Madison Man— on 1210423 03:43 PM Page 8 "18 PRE -INSTALLATION O Verify module compatibility. See Page 21 for info. TOOLS REQUIRED ❑ Cordless Drill (non -impact) ❑ 3/8" Socket ❑ Impact Driver (for lag bolts) ❑ 1/8" Drill Bit ❑ Torque Wrench (0-250 in-Ibs) ❑ 1/4" Drill Bit ❑ 7/16" Socket ❑ T30 Bit ❑ 1/2" Socket ❑ Channel Lock Pliers ❑ 9/16" Socket ❑ #3 Phillips Bit ❑ 7/32" Drill Bit ❑ 3/16" Hex Bit BONDING HARDWARE TORQUE VALUES Please refer to each attachment's individual section for full details on all torque values and instructions. ❑ 3/8" Bonding Hardware Nuts (7/16" Socket): 250 in-Ibs ❑ All Tile Hook Carriage Bolts (7/16" Socket): 132 in-Ibs ❑ Flat Roof Attachment Nuts (9/16" Socket): 250 in-Ibs ❑ Lynx Set Screw (3/16" Hex Drive): 150 in-Ibs ❑ Lynx Flange Nut (1/2" Socket): 150 in-Ibs ATTACHMENTS COMPOSITION SHINGLE c FlashFoot2 FlashVue QM L-Mount < A> QM QBase QM Classic Comp HUG Mount (Halo UltraGrip) TILE Knockout Tile QM Tile Replacement All Tile Hook and Flashing (optional) QM Quick Hook and QM QBase Tile QM Tile Conduit Flashing (optional) Penetration ADDITIONAL ROOF TYPES < > <:: > QM Qbase Shake - QM Classic Mount QM Lynx Metal Roof Slate - Metal Shingle Shake Attachment LOW SLOPE ROOF ro If using previous version of Integrated Grounding Mid Clamps, Flat Roof Attachment QM QBase Mount End Clamps, Expansion Joints and for a list of approved 3rd party components please refer to Alternate Components Addendum (Version 1.9) PRE -INSTALLATION O Verify module compatibility. See Page 21 for info. TOOLS REQUIRED ❑ Cordless Drill (non -impact) ❑ 1/8" Drill bit ❑ Impact Driver (for lag bolts) ❑ 1/4" Drill bit ❑ Torque Wrench (0-250 in-Ibs) ❑ T30 Torx Bit ❑ 7/16" Socket ❑ Channel Lock Pliers ❑ 1/2" Socket ❑ #3 Phillips Bit ❑ 9/16" Socket ❑ Paddle Bit ❑ 7/32" Drill bit BONDING HARDWARE TORQUE VALUES Please refer to each attachment's individual section for full details on all torque values and instructions. ❑ Universal Fastening Object (7/16" Socket): 80 in-Ibs ❑ Rail Grounding Lug Nut (7/16" Socket): 80 in-Ibs ❑ Module Grounding Lug ❑ Grounding Nut (7/16" Socket): 60 in-Ibs ❑ Grounding Lug Terminal Screws (7/16" Socket): 20 in-Ibs ❑ Microinverter Kit Nuts (7/16" Socket): 80 in-Ibs ❑ Frameless Module Kit Nuts (7/16" Socket): 80 in-Ibs ❑ 3/8" Bonding Hardware Nuts (7/16" Socket): 250 in-Ibs ❑ Contour Clamp (T-30 Torx Bit): 80 in-Ibs COMPONENTS XR Rail Wire Clip BOSS ® o UFO and Stopper CAMO Ironridge L-Foot and Sleeve (30-46MM) QM L-Foot End Cap Rail Grounding Lug Module Grounding Lug J Microinverter Kit 3/8" Bonding 8" Bonding Jumper Hardware Single Use Only QM Classic Conduit JAYBOX QM Composition Comp Mount Conduit Penetration QM Tile Conduit Frameless Frameless Module Kit Mount End/Mid Clamp D Unless otherwise noted, all components have been evaluated for multiple use. They can be uninstalled and reinstalled in the same or new location. Contour Trim Contour Clamp Flush Mount System Span Table (inches) - Portrait or Landscape Installation Max Module Length: 78.5", Max Module SF: 24 SF Exposure B W ind Roof Ground Snow: psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf* 80 psf* 90 psf* 100 psf* 110 psf* 120 psf* Speed m h P. de . Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 110 g-27 121 309 87 100 100 87 84 84 84 83 83 83 76 76 76 72 72 72 64 64 64 59 59 59 55 55 55 52 52 52 50 50 50 48 48 48 48 48 48 m h 28-45 118 118 118 98 98 98 84 84 84 83 83 83 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 115 8-27 121 104 83 100 100 83 84 84 83 83 83 83 76 76 76 72 72 72 64 64 64 59 59 59 55 55 55 52 52 52 50 50 50 48 48 48 48 48 48 mph 28-45 114 114 114 98 98 98 84 84 84 83 83 83 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 120 8-27 121 100 80 100 100 80 84 84 80 83 83 80 76 76 76 72 72 72 64 64 64 59 59 59 55 55 55 52 52 52 50 50 50 48 48 48 48 48 48 mph 28-45 111 110 110 98 98 98 84 84 84 83 83 83 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 130 8-27 118 92 74 100 92 74 84 84 74 83 83 74 76 76 74 72 72 72 64 64 64 59 59 59 55 55 55 52 52 52 50 50 50 48 48 48 48 48 48 mph 28-45 305 103 103 97 97 97 84 84 84 83 83 83 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 140 8-27 115 85 68 100 85 68 84 84 68 83 83 68 76 76 68 72 72 68 64 64 64 59 59 59 55 55 SS 52 52 52 50 50 50 48 48 48 48 48 48 mph 28-45 100 96 96 96 96 96 82 82 82 81 81 81 75 75 75 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 150 8-27 107 79 64 100 79 64 84 79 64 83 79 64 76 76 64 72 72 64 64 64 64 59 59 59 55 55 55 52 52 52 50 50 50 48 48 48 48 48 48 m h 28-45 96 90 90 91 90 90 80 80 80 79 79 79 74 74 74 72 72 72 65 65 65 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 8-27 101 74 60 100 74 60 84 74 60 83 74 60 76 74 60 72 72 60 64 64 60 59 59 59 55 55 55 52 52 52 50 50 50 48 48 48 48 48 48 28-45 90 85 85 88 85 85 78 78 78 77 77 77 72 72 72 68 68 68 64 64 64 61 61 61 58 58 58 56 56 56 53 53 53 51 51 51 49 49 49 8-27 96 72 55 96 72 55 83 72 55 82 72 55 75 72 55 72 72 55 64 64 55 59 59 55 55 55 55 52 52 5250 50 50 48 48 48 48 48 48 t116 28-45 86885 80 80 76 76 76 75 75 75 72 72 72 66 66 66 64 64 64 60 60 60 58 58 58 55 55 55 53 53 53 51 51 51 49 49 49 8-27 90 66 48 90 66 48 82 66 48 81 66 48 74 66 48 69 66 48 64 64 48 59 59 48 55 55 48 52 52 48 50 50 48 48 48 48 48 48 48 28-45 82 76 76 82 76 76 74 74 74 73 73 73 69 69 69 65 65 65 64 64 64 59 59 59 57 57 57 55 55 55 53 53 53 51 51 51 49 49 49 = min 72'. soan md= min 64" soan = min 48" soan = Note: additional installation reauirementfor CAMO module clamp. See Note 12 on Page 3 for details. REV 03/05/2021 _ = Shaded cells indicate conditions in which UFO Mid Clamp connection capacity is exceeded. See Note 10 on page 2 for details.