APPROVED BLD PLN BLD2020-1033+Architectural_Plan+3.8.2021_4.10.37_PM+2081733GENERAL NOTES AREA CALCULATIONS _ � �� GENERAL REQUIREMENTS ALL WORK SHALL COMPLY WITH THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN), HEATED AREAS SQUARE FOOTAGE ,. _ � ' INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE, _ �_ =�� INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE 2ND FLOOR 999.0 AND LOCAL AMENDMENTS, AND ANY APPLICABLE LAND USE CODE. MAIN FLOOR 153.0 - - �- "�_��--" THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO __ __ CONSTRUCT AWEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND TOTAL 1152.0 __ _ � .y -�. WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE � _ _ - _ RESPONSIBILITY OF THE OWNER/BUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE. NON -HEATED AREAS SQUARE FOOTAGE -,e THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR -- - - �" -- CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL GARAGE AND SHOP 1974.0 _ _ _ - - _____ --- - -- . � �' �� _ BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND COVERED PORCHES 173.0 _-- _ _ �'{ ;�;`� WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNER/BUILDER'S APPROVAL BEFORE BEING - �rr COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE y INTENDED OWNER/BUILDER IS NOT PERMITTED. - " ��. -: ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE. � ; - ���. - _-- - _�. SITE WORK .� - = - _ _ - - 1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. (1 1/2-3/8 CLEAN �� I� WASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE AND - WATERPROOFING. r 2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS `'�� BELOW FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES. 3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO � _ � �� '� `. � - � 4, `"''�•� ___ ROOF AND STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDE TIGHT LINE CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES. �' J ~\ } r � �``� � __�---� 4. ROCKERIES AND RETAINING WALLS SHALL BE DESIGNED BY A LICENSED ENGINEER AND INSTALLED PER DRAWING INDEX -�� �- APPLICABLE CODE. -�� -� - MECHANICAL .,�. - �. _ 1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT, EXPERIENCED PLUMBER AND IN SHEET NO. DESCRIPTION �.""`�� _ ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES. �� • „ __ 2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED MECHANICAL ��-� CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2015 IRC, AND LOCAL CODES. PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE Al COVER SHEET, INDEX, GENERAL NOTES , - - WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH A2 ENERGY CALCULATIONS _ - r .. .. �'. � ,Q. - - _ .. - v THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE THE � �� .� � , � � GARAGE FLOOR. A3 ELEVATIONS � � '"�`�� �:� � � � -• ' �, A4 ELEVATIONS - � � f � � �� �� � �� THERMAL AN D MOISTU RE A5 MAIN FLOOR PLAN A6 2ND FLOOR PLAN 1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE ,q7 BUILDING SECTIONS AND MISC. DETAILS OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON A8 BUILDING SECTIONS &DETAILS PLANS OR ON A SEPARATE ENERGY CALCULATION SHEET. 2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION A9 BUILDING SECTION AND DETAILS WALLS, FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE.. (R406.1) S1 STRUCTURAL NOTES/SCHEDULES 3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER S2 FOUNDATION PLAN MANUFACTURER'S INSTRUCTIONS. 4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER IN ALL CRAWLSPACE AREAS, LAPPED AT ALL SPLICES S3 2ND FLOOR FRAMING AND OVER FOOTINGS. S4 ROOF FRAMING PLAN FINISHES S5 STRUCTURAL DETAILS S6 STRUCTURAL DETAILS GARAGE CEILINGS BENEATH HABITABLE SPACES SHALL BE COVERED WITH 5/8" TYPE "X" GYPSUM WALL BOARD. GARAGE CEILINGS BENEATH ATTIC OR NON LIVING SPACE SHALL BE COVER WITH 5/8" GYPSUM WALL BOARD. WALLS AND STRUCTURE SEPARATING RESIDENTIAL AND GARAGE SPACES SHALL BE COVERED WITH 1/2" GYPSUM WALL BOARD. ALL GARAGE GYPSUM WALLBOARD SHALL HAVE JOINTS FIRETAPED WITH NAILS SET AND COMPOUNDED. ALL OTHER WALLS SHALL RECEIVE 1/2" GYPSUM WALLBOARD. CEILINGS WITH JOISTS/ TRUSS SPACES GREATER THAN 16" SHALL RECEIVE 5/8" GYPSUM WALLBOARD OR 1/2" GYPSUM CEILING BOARD. WALLS SURROUNDING TUBS OR SHOWERS SHALL BE COVERED WITH WATER-RESISTANT GYPSUM WALL BOARD. WATER- PROOF SURFACE TO A HEIGHT OF 72" ABOVE ADJACENT FLOOR. ANY CEMENT PLASTER OR STUCCO SHALL BE INSTALLED IN ACCORDANCE WITH NORTHWEST WALL AND CEILING BUREAU RECOMMENDATIONS FOR MATERIALS, BACKING, LATH, APPLICATION TECHNIQUES, AND FINISHES. ELECTRICAL SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN SYMBOL L E G E N D ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY. F I R ESTO P P I N G CARBON MONOXIDE DETECTOR ❑ INTERCONNECTED 110v w/ BATTERY BACKUP c.o. CAN BE COMBINED w/ S.D. FIRESTOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND O SMOKE DETECTOR HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND s.D. INTERCONNECTED 110v w/ BATTERY BACKUP THE ROOF SPACE. FIRESTOPPING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING LOCATIONS: O EXHAUST FAN (VENT TO OUTSIDE) A rove d b � F � re 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES NOT TO EXCEED 10'-0" p p y HORIZONTALLY, AND AT THE CEILING AND FLOOR LEVEL. 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT O KEYNOTE 03/31/2021 AFM ���t-tee-e�- APPROVED BY PLANNING SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND WALL CAVITIES IN LINE WITH STRINGERS. 101 DOOR SCHEDULE SYMBOL �� 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL, WITH NON-COMBUSTABLE MATERIALS. 11 WINDOW SCHEDULE SYMBOL Mar 29 2021 REVISION- SEE DESCRIPTION IN MISCELLANEOUS TITLE BLOCK 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. SIM DETAIL SYMBOL 1 � 2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND SIMILAR DETAIL 101 ELECTRICAL WORK. -DETAIL N0. 3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND SHEET N0. APPROVED BY INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314) CARBON MONOXIDE SIM 1 C it ❑�O �d ❑ o n d s � BUILDING CROSS SECTION CITY OF EDMONDS ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE A10�,� BEDROOMS. (R315) DETAIL N0. � BUILDING DIVISION Buildin De artment g p 4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE SHEET NO. Mar 3O 2021 BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS. --------- 5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO Room name � -ROOM NAME Work NEW SFR MAKE THEM WATERPROOF. ROOF FLASHING PER R903. ____ 6. GUARDRAILS TO BE A MIN. OF 36" ABOVE FINISH FLOOR. (R312) (EXCEPTIONS TO COMMERCIAL PER I.B.C.) APPROVED " " """""""""""" Address 10731 226TH ST SW LOT 1 7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN DIAMETER CANNOT PASS THROUGH. PLANS MUST BE 8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM Owner HELLEREN NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT OF ON JOB SITE _________ 44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310.1). �--�--� Approved Date 3/30/2021 RESUB r � Know what's below■ STATE LAW REQUIRES THAT YOU CALL BEFORE YOU DIG TO Call before dig. LOCATE ALL UNDERGROUND UTILITIES. OBTAIN ELECTRICAL qLL WORK SUBJECT PERMIT FROM TO FIELD Buildin Official � w. � Mar 09 2021 9 ------CITY OF EDMONDS ���--�--� """' DEVELOPMENT SERVICES Permlt Number DEPARTMENT you STATE LABOR & INSPECTION FOR BLD2020-1033 ________ INDUSTRIES CODE COMPLIANCE U Z N Z Q � a �� Y 2 0� W d m W � N �� o � � °� J J�� U ��� M � � Z � o .� LJJ N 'm � o °�' W m J � W a H +�= U C �� . � C Q) ALA'' W N Z U N -U L �, N -O �, -O 0 N O O O N@ J S tO16 N A N O y T i �L-' (n y 'N 3 N O E T p y O Z J U� O C O r �@ L° O N d d. Nam :�� ° s ~ ° � � m U E �' O o moo"¢ ° °� �� m a y �s�= m � � E y aw� �Ea`"iy�cna`�i�o�do-NOo O W �_ o� o U o o�y o�� 3 c� N° _U w U J J H C U °- O U �- O.�N N O �� O <6 W o @ a�� E � °� �-� F Z no �� O m of E� a� W W /� W Z W Z W W J W W �_ W �_ uJ O 0 c 0 .� .� 0 z PROJECT NO. 200305 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 9/20/2020 2:31:57 PM R301 CLIMATE ZONE THIS PLAN IS DESIGNED FOR CLIMATE ZONE 5 AND MARINE 4 PER TABLE R301.1, 2015 WASHINGTON STATE ENGERY CODE. R402.2 FENESTRATION (PRESCRIPTIVE) R402.3 Fenestration (Prescriptive). In addition to the requirements of Section R402, fenestration shall comply with Sections R402.3.1 through R402.3.6. R402.3.1 U-factor. An area -weighted average of fenestration products shall be permitted to satisfy the U-factor requirements. R402.3.2 Glazed fenestration SHGC. An area -weighted average of fenestration products more than 50 percent glazed shall be permitted to satisfy the SHGC requirements. R402.3.3 Glazed fenestration exemption. Up to 15 square feet (1.4 m2) of glazed fenestration per dwelling unit shall be permitted to be exempt from U-factor and SHGC requirements in Section R402.1.1. This exemption shall not apply to the U- factoralternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4. R402.3.4 Opaque door exemption. One side -hinged opaque door assembly up to 24 square feet (2.22 m2) in area is exempted from the U-factor requirement in Section R402.1.1. This exemption shall not apply to the U-factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4 R404.1 LIGHTING EFFICACY MIN. OF 75%OF LAMPS IN PERMANENTLY INSTALLED FIXTURES SHALL BE HIGH EFFICACY LAMPS. M 1507 MECHANICAL VENTILATION M1507.3.1 SYSTEM DESIGN. EACH DWELLING UNIT OR GUESTROOM SHALL BE EQUIPPED WITH A VENTILATION SYSTEM COMPLYING WITH SECTION M1507.3.4, M1507.3.5, M1507.3.6 OR M1507.3.7. COMPLIANCE IS ALSO PERMITTED TO BE DEMONSTRATED THROUGH COMPLIANCE WITH THE INTERNATIONAL MECHANICAL CODE. M1507.3.2 CONTROL AND OPERATION. 1. LOCATION OF CONTROLS. CONTROLS FOR ALL VENTILATION SYSTEMS SHALL BE READILY ACCESSIBLE BY THE OCCUPANT. 2. INSTRUCTIONS. OPERATING INSTRUCTIONS FOR WHOLE -HOUSE VENTILATION SYSTEMS SHALL BE PROVIDED TO THE OCCUPANT BY THE INSTALLER OF THE SYSTEM. 3. LOCAL EXHAUST SYSTEMS. LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS. 4. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS SHALL OPERATE CONTINUOUSLY. EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS SHALL BE EQUIPPED WITH "FAN ON" AS OVERRIDE CONTROLS. CONTROLS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. A LABEL SHALL BE AFFIXED TO THE CONTROLS THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)." 5. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS SHALL COMPLY WITH THE FOLLOWING: 5.1. THEY SHALL BE CAPABLE OF OPERATING INTERMITTENTLY AND CONTINUOUSLY. 5.2. THEY SHALL HAVE CONTROLS CAPABLE OF OPERATING THE EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. 5.3. THE VENTILATION RATE SHALL BE ADJUSTED ACCORDING TO THE EXCEPTION IN SECTION 403.8.5.1. 5.4. THE SYSTEM SHALL BE DESIGNED SO THAT IT CAN OPERATE AUTOMATICALLY BASED ON THE TYPE OF CONTROL TIMER INSTALLED. 5.5. THE INTERMITTENT MECHANICAL VENTILATION SYSTEM SHALL OPERATE AT LEAST ONE HOUR OUT OF EVERY FOUR. 5.6. THE SYSTEM SHALL HAVE A MANUAL CONTROL AND AUTOMATIC CONTROL, SUCH AS A 24-HOUR CLOCK TIMER. 5.7. AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL SHALL BE SET TO OPERATE THE WHOLE -HOUSE FAN ACCORDING TO THE SCHEDULE USED TO CALCULATE THE WHOLE -HOUSE FAN SIZING. M1507.3.4 WHOLE -HOUSE VENTILATION USING EXHAUST FANS. THIS SECTION ESTABLISHES MINIMUM PRESCRIPTIVE REQUIREMENTS FOR WHOLE -HOUSE VENTILATION SYSTEMS USING EXHAUST FANS. A SYSTEM WHICH MEETS ALL THE REQUIREMENTS OF THIS SECTION SHALL BE DEEMED TO SATISFY THE REQUIREMENTS FOR AWHOLE-HOUSE VENTILATION SYSTEM. M1507.3.4.1 WHOLE -HOUSE VENTILATION FANS. EXHAUST FANS PROVIDING WHOLE -HOUSE VENTILATION SHALL HAVE A FLOW RATING AT 0.25 INCHES WATER GAUGE AS SPECIFIED IN TABLE M1507.3.3(1). MANUFACTURERS' FAN FLOW RATINGS SHALL BE DETERMINED ACCORDING TO HVI 916 OR AMCA 210. M1507.3.4.2 FAN NOISE. WHOLE -HOUSE FANS LOCATED 4 FEET OR LESS FROM THE INTERIOR GRILLE SHALL HAVE A SONE RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE. MANUFACTURER'S NOISE RATINGS SHALL BE DETERMINED AS PER HVI 915 (MARCH 2O09). REMOTELY MOUNTED FANS SHALL BE ACOUSTICALLY ISOLATED FROM THE STRUCTURAL ELEMENTS OF THE BUILDING AND FROM ATTACHED DUCT WORK USING INSULATED FLEXIBLE DUCT OR OTHER APPROVED MATERIAL. M1507.3.4.3 FAN CONTROLS. THE WHOLE -HOUSE VENTILATION FAN SHALL MEET THE REQUIREMENTS OF SECTION M1507.3.2 AND M1507.3.2.1. M1507.3.4.4 OUTDOOR AIR INLETS. OUTDOOR AIR SHALL BE DISTRIBUTED TO EACH HABITABLE SPACE BY INDIVIDUAL OUTDOOR AIR INLETS. WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT TO A MINIMUM OF 1/2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING. INDIVIDUAL ROOM OUTDOOR AIR INLETS SHALL: 1. HAVE CONTROLLABLE AND SECURE OPENINGS; 2. BE SLEEVED OR OTHERWISE DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES OF THE WALL OR WINDOW IN WHICH THEY ARE PLACED; 3. PROVIDE NOT LESS THAN 4 SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH HABITABLE SPACE. ANY INLET OR COMBINATION OF INLETS WHICH PROVIDE 10 CFM AT 10 PASCALS ARE DEEMED EQUIVALENT TO 4 SQUARE INCHES NET FREE AREA. INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR OTHER MATERIAL. OUTDOOR AIR INLETS SHALL BE LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING AREAS: 1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 FEET ABOVE THE OUTDOOR AIR INLET. 2. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS. 3. A HAZARDOUS OR UNSANITARY LOCATION. 4. A ROOM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN. 5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET. 6. ATTIC, CRAWL SPACES, OR GARAGES. TABLE 1507.3.3 (1) CONTINUOUS WHOLE HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW FLOOR AREA BEDROOMS (SQ. FT.) 0-1 2-3 4-5 6-7 >7 < 1500 30 45 60 75 90 (IN CFM's) 1501-3000 45 60 75 90 105 3001-4500 60 75 90 105 120 4501-6000 75 90 105 120 135 6001-7500 90 105 120 135 150 >7500 105 120 135 150 165 TABLE 1507.3.3 (2) INTERMITTENT WHOLE HOUSE MECHANICAL VENTILATION RATE RUN-TIME PERCENTAGE IN EACH 4-HOUR SEGMENT 25% 33% 50% 66% 75% 100% FACTOR 4 3 2 1.5 1.3 1.0 THIS PLAN USES AN INTERMITTENT WHOLE HOUSE VENTILATION SYSTEM WITH TOTAL HEATED FLOOR AREA = 1152 SQ. FT. BEDROOMS = 2 WHOLE HOUSE VENTILATION SIZE = 45 CFM X 4 (25°/t, PER 4-HOUR) = 180 TOTAL CFM FAN(s) SIZE. INTEGRATED FURNACE OUTSIDE AIR INTAKE WITH EXHAUST FANS AS NOTED IN PLAN . MULTIPLE WHOLE HOUSE VENTILATION FANS TO BE INTERCONNECTED TO OPERATE SIMULTANEOUSLY. 2015 WASHINGTON STATE ENERGY CODE MISC. ENERGY CODE NOTES A permanent certificate shall be completed and posted on or within three feet of the electrical distribution panel by the builder or registered design professional. The certificate shall be completed by the builder or registered design professional and shall not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, below -grade wall, and/or floor) and ducts outside conditioned spaces; U-factors for fenestration and the solar heat gain coefficient (SHGC) of fenestration, and the results from any required duct system and building envelope air leakage testing done on the building. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the types and efficiencies of heating, cooling and service water heating equipment. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Where the primary heating system is a forced -air furnace, at least one thermostat per dwelling unit shall be capable of controlling the heating and cooling system on a daily schedule to maintain different temperature set points at different times of the day. Specifics and Exceptions see SEC. ALL DUCTWORK SHALL BE SEALED AND TESTED PER R403.2.2. WINDOW AND DOOR HEADERS SHALL BE INSULATED WITH R-10 RIGID INSULATION EXCEPT IN SITUATIONS WHERE STRUCTURAL BEAM SIZE REQUIREMENTS OVERRIDE. ALL APPLIANCES SHALL BE U.L. LISTED. WHOLE HOUSE FANS Whole house ventilation fans shall be installed so as to run simultaniously. EXHAUST FANS Exhaust fans to terminate at building exterior with clearances per SRC M1506.2 (min. 3 ft to openings) and for clothes dryer vent terminations to be per M1502.3 (3 ft to bldg. openings). ALL FENESTRATION SHALL BE NFRC CERTIFIED. >_x6 TOP PLATES .W.B. iID R-10 INSULATION �LLED IN CAVITY BETWEEN ER AND INTERIOR G.W.B. ER PER PLAN ,r.�OW, FINISH &TRIMS PER MISC. DETAILS HEADER INSULATION PRESCRIPTIVE ENERGY CODE COMPLIANCE Prescri tive Ener Code Com liance for All Climate Zones in Washin ton p 9Y p 9 Project Information Contact Information HELLEREN RESIDENCE &SHOP -LOT 1 LEIF AND KIM HELLEREN This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative All Climate Zones R-Valuea U-Factora Fenestration U-Factorb n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGCb�e n/a n/a Ceilingk 49' 0.026 Wood Frame Wallgm�n 21 int 0.056 Mass Wall R-Value' 21/21h 0.056 Floor 30g 0.029 Below Grade Wallc m 10/15/21 int + TB 0.042 Slabd R-Value &Depth 10, 2 ft n/a able K4UL.1.1 and I able K4UL.1.3 Footnotes included on Page 2. Date Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit: 1.5 credits ❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. 0 2. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. ❑ 3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. ❑ 4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Ootion Description Credit(sl 1a Efficient Building Envelope 1a 0.5 1 b Efficient Building Envelope 1 b 1.0 1c Efficient Building Envelope 1c 2.0 1d Efficient Building Envelope 1d 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 5d Efficient Water Heating 5d 0.5 6 Renewable Electric Energy 0.5 Total Credits *Please refer to Table R406.2 for complete option descriptions *1200 kwh 1.5 0.0 1.50 ENERGY CREDITS Sc EFFICIENT WATER HE_�TING Sc: 1.� ��'ater heating system shall include one of the following: Gas, propane or oil water heater with a miuinnun EF of 0.91 ur� Solar �irater heating supplemeuttug a miuiuuuu staztdard water heater. Solar water heating �'vill provide a rated nuniuntm savings of 85 thenus or 2000 kti�'lt Uased ou the Solar Rating and Cectiftcation Corporation (SRCC) AtuivaI Perfomtauce of QG-300 Certified Solar [rater Heating Systems Dr' Elecn�ic heat pump 4vater heater �S�ith a nvnimum FF of 2.0 and meetius the standards of NEEA's Nar7her7s Climate Specifications for Heat Pump tiTt'ater Heaters To qualify° to claiu> this credit. the UuiLduta penuit dra',r°utgs shall specify the option Uevtg selected and shall specify the ���ater heater equipment type and the mntimam equipment efficiency and, for solar '<r•ater heating systems, the calcnlatint� of the utit�inxttu euerBy savings. FENENSTRATION CALCULATIONS VERTICAL GLAZING 180 SF LESS EXEMPT GLAZING AT GARAGE -45 SF PLUS GLAZED DOORS 42 SF PLUS OTHER EXTERIOR DOORS 84 SF TOTAL FENESTRATION: 261 SF NOTE: SEE SHEET A7, A8 & A9 FOR ADDITIONAL INSULATION LOCATIONS AND DETAILS. TABLE R402.1.1 FOOTNOTES Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. ` "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21,+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Reserved. g Reserved. I, Reserved. ' The second R-value applies when more than half the insulation is on the interior of the mass wall. 'Reserved. I< For single rafter- orjoist-vaulted ceilings, the insulation may be reduced to R-38. I Reserved. m Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. HEATING SYSTEM SIZE slm le rleatln � stem slze: wasnln ton state p 9 Y 9 This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Enerpv Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heatino loads only. ACCA procedures for sizino coolino systems should be used to determine coolino loads. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information HELLEREN RESIDENCE &SHOP -LOT 1 LEIF &KIM HELLEREN 1 Heating $VStem Type: O All other Systems OO Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (4T) 46 Edmonds � 4T =Indoor (70 degrees) -Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) Average Ceiling Height Instructions Average Ceiling Height (ft) Glazing and Doors Instructions U-0.30 � , Skylights Instructions Insulation Attic Instructions R�9 Single Rafter or Joist Vaulted Ceilings Instructions � R-38 Vented � I Above Grade Walls tree Figure +� Instructions � R-21 Intermediate � I Floors 1,152 Conditioned Volume 8.2 9,446 U-Factor X Area = UA 0.300 261 78.30 U-Factor X Area = UA 0.50 0� --- U-Factor X Area = UA 0.026 602 15.65 U-Factor X Area UA 0.027 550 14.85 U-Factor X Area UA 0.056 1,736 97.22 U-Factor X Area UA Instructions 0.029 1,152 I 33.41 R-30 � Below Grade Walls (see Figure tl U-Factor X Area UA RES U B Instructions 0.042 387 16.25 R-21 Interior � � Mar 09 2021 Slab Below Grade see Figured F-Factor X Length UA Instructions 0.303 36 10.91 CITY OF EDMONDS R-70 Fully insulated � DEVELOPMENT SERVICES DEPARTMENT Slab on Grade tree Fi ure t F-Factor X Length UA Instructions � 0.360 36 12.96 R-10 Fuly Insulated Location of Ducts Instructons Duct Leakage Coefficient No Ducts � t.00 Sum of UA 279.55 Envelope Heat Load 12,859 Btu /Hour Flaure 1. Sum of UAXdT Air Leakage Heat Load 4,693 Btu /Hour Volume X 0.6 X �T X .078 Above Grade Building Design Heat Load 17,552 Btu /Hour _ Air Leakage +Envelope Heat Loss Building and Duct Heat Load 17,552 Btu /Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 21,940 Btu /Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 /or Heat Pump (07/01/13J U Z N W O i � Z Q E a �� � Y = �, w a �, w u-, � � C O "� °' U J�� ��o Mew Z � O ,C W � �� � o °E' W m � o � a H �\ E O u C .� H C Q) ALA'' W U °'gigs a�i a�-allou, `oo Z r"o m"ciu tmmm�ow.- oZ�o�o�Ot=am@ucioaci �°n Nam c'�''OL~O���YUEaai�o Spa ao-3-ow o i= c m cUi `off ayi �"u O LL Q��� � m c y� s =gym � 5 E y p W� U o i; w ii U o o .� � c 3 c� o u U J J H c m � �- o U �- a�m m U y a o oaoa�� °Ej° `oL��°' W W �� W W Z W W J W W �_ W �_ uJ O J .�. m 0 c 0 .� .� 0 z PROJECT NO. 200305 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 9/20/2020 2:32:14 PM ELEVATION NOTES PROVIDE METAL FLASHING OVER TOPS OF WINDOWS AND TOPS OF TRIMS DIRECTLY EXPOSED TO WEATHER. ROOFING MATERIAL, SIDING AND FLASHING SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, INDUSTRY STANDARDS AND PER I.R.C. PORCHES, BALCONIES, RAMPS OR RAISED SURFACES LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36" IN HEIGHT. OPEN SIDE OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLY FROM THE NOSING OF THE TREADS. INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES SHALL BE SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. THE TRIANGLE OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM OF RAIL SHALL BE SUCH THAT A 6" SPHERE CANNOT PASS THROUGH. EXTERIOR STAIRS SHALL BE NOT LESS THAN 36"WIDE. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5" ON EITHER SIDE OF THE STAIRWAY AND MIN. CLEAR WIDTH AT OR BELOW THE HANDRAIL SHALL NOT BE LESS THAN 31.5". MAX. RISER HEIGHT IS 7 3/4". MIN. TREAD DEPTH SHALL BE 10". A LANDING IS REQUIRED AT TOP AND BOTTOM OF EACH STAIRWAY. SITE ADDRESS SHALL BE VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. NUMBERS SHALL CONTRAST WITH BACKGROUND, BE ARABIC NUMBERS OR ALPHABETICAL LETTERS, BE A MIN. OF 4" IN HEIGHT WITH A MIN. STROKE WIDTH OF 1/2". (R319.1) OrainEdge '°' strip �'"��' f WeatherSealtrowel-applied rnernhrane " . �=:� � , . � � � ` �` �; Step fashirg taped and sealed . - � ' �, -� ` �`�_�` `t Kick-outflashing R l _ - ; . ; '�., .��' I, � �,� Kick -out and fascia `: _ .�-:_:r,. ` f '•.,, �� taped and sealed Wall sheathing 2�, KICKOUT FLASHING DETAIL Max. Height 298' - 8 1 /2" 297'-7"---- 39 45 CV 40 N i I � � � ■ � -�, Max. Hei hg t � TOP OF RIDGE I1 298' - 8 1/2" 1 LATE 9'-9" ILING 7'-0" 00$ 1 1/8" grade � 8 1 /2" �I _00� 0' �--0" SO UTH E LEVATI O N ELEVATION KEYNOTES KEY VALUE KEYNOTE TEXT 39 40+YEAR PRESIDENTIAL RANDOM CUT ARCHITECTURAL COMPOSITION ROOFING 40 STANDING SEAM METAL ROOFING. COLOR AND STYLE PER OWNER SPECIFICATIONS 41 CONTINUOUS ALUMINUM GUTTER ON 5/4x6 FASCIA 42 BOARD AND BATTON: 1x3 BATTONS @ 16" O.C. ON HARDI-BOARD OR EQUIV. SMOOTH FACED BOARDS 45 FASCIA: 1x4 ON 5/4x10 (TYPICAL AT GABLE ENDS) 50 HORIZONTAL BEVEL CEMENT BOARD SIDING PER BUILDER SPECS 59 5/4x4 CORNER TRIM 61 2x10 BELLY BAND w/METAL FLASHING 67 WINDOW WRAP: 5/4x6 SIDE RAILS w/ 2x8 TOP RAIL AND 2x3 DRIP SILL OVER 5/4x8 TRIM. PROVIDE HEAD FLASHING OVER ALL WINDOWS NOT UNDER EAVES AND/OR EXPOSED TO WEATHER. 71 BOX FRAME POST BASE AND WHITE WOOD TRIMS o/ STRUCTURAL POST PER PLAN 83 PROVIDE 6" MINIMUM EARTH/WOOD CONTACT 85 LOCKING DEADBOLD AT ENTRY DOOR 86 CONCRETE LANDING AND STEPS PER I.R.C./I.B.C. 87 INSULATED STEEL OVERHEAD GARAGE DOOR. MAKE AND STYLE PER BUILDER/OWNER SPECIFICATIONS. 96 PROVIDE METAL HEAD FLASHING ABOVE ALL WINDOWS EXPOSED TO WEATHER. RESUB Mar 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U Z N o rn Z a � a �� � Y= rn wa•�, ��a "� O °' J� U �m� M CO � Z � N C W � �� � o �' W m � o W a F +»�= O U C ,� �tl -. C Q) .�r® !�� ALA'' W z ������ ��,=���oa C �}� r (n (� N 3 J" N E a a� N Q o Z J p U Cp C O L �= � (0 (Op N O N� d O C Nam C .0 :: O L H p T j L U E O N 2�a c c m�~���� n�-�a`� O J N p, C O O_ @ t6 O� (0 N O .t.. � U LL �� r C N O L� Q~ '= � 10 C E N O W� U£ O U Co U EO p C C� ?� ��N N U UJ J— H U a0O 0.0 •-�-0 N � O H C {p N O. (6 � � Z a O�� N N N� O� E� N W W 0 /� W pC z W ZW W W � _ W �_ W �_ uJ O J 0 0 .� .� 0 Z PROJECT NO. 200305 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 9/20/2020 2:32:37 PM ELEVATION KEYNOTES � MaX. Hei hg t KEY VALUE KEYNOTE TEXT v 298' - 8 1/2" �O��TgO7P OF RIDGE _ _ _ _ _ 39 40+YEAR PRESIDENTIAL RANDOM CUT ARCHITECTURAL COMPOSITION ROOFING -'" " - 711 40 STANDING SEAM METAL ROOFING. COLOR AND STYLE PER OWNER SPECIFICATIONS 9�i 41 CONTINUOUS ALUMINUM GUTTER ON 5/4x6 FASCIA ���� 42 BOARD AND BATTON: 1x3 BATTONS @ 16" O.C. ON HARDI-BOARD OR EQUIV. SMOOTH FACED BOARDS 45 FASCIA: 1x4 ON 5/4x10 (TYPICAL AT GABLE ENDS) 50 HORIZONTAL BEVEL CEMENT BOARD SIDING PER BUILDER SPECS 59 5/4x4 CORNER TRIM \� �2 61 2x10 BELLY BAND w/METAL FLASHING �, 112' �_ 67 WINDOW WRAP: 5/4x6 SIDE RAILS w/ 2x8 TOP RAIL AND 2x3 DRIP SILL OVER 5/4x8 TRIM. PROVIDE HEAD FLASHING OVER ALL WINDOWS NOT 96 iy UNDER EAVES AND/OR EXPOSED TO WEATHER. � 2ND FLOOR PLATE � 71 BOX FRAME POST BASE AND WHITE WOOD TRIMS o/ STRUCTURAL POST PER PLAN — — — — — — - — a' — — — 289, _ 9" 83 PROVIDE 6" MINIMUM EARTH/WOOD CONTACT 85 LOCKING DEADBOLD AT ENTRY DOOR 42 , 86 CONCRETE LANDING AND STEPS PER I.R.C./I.B.C. RV BAY CEILING 87 INSULATED STEEL OVERHEAD GARAGE DOOR. MAKE AND STYLE PER BUILDER/OWNER SPECIFICATIONS. — — — — — — — — — — 2$7' - O" 96 PROVIDE METAL HEAD FLASHING ABOVE ALL WINDOWS EXPOSED TO WEATHER. 67 ,� � o 5'�12 O 83 _ 0 O o 2ND FLOOR — — — — — — — — 281' - 7 7/8" - — — - ,. — �+I-�����—���+�_MAINFLOORPLATE 280 -1 1 /8 � Avera 8e1 trade �� i i � u� � �� �� �� u� � u�� I�� O�� � � �� � i�� I�� � u�� FAIN FLOOR 270' - o° NORTH ELEVATION 3D View 1 Max. Hei hg t � TOP OF RIDGE 298' - 8 1/2�' 1 297' 7" 01 ., _ . � � •�' 1 � :• • I% � I III 11 ���I �%� I III II �� �I\ � - = �_ i �V ..i !�' \ `�� � i � � � � i i � i i h� i � i � II����� II�h ����h��������� ������� ��� � 2ND FLOOR 281' - 7 7/8" MAIN FLOOR PLATE - — — 280' -1 1 /8�� III I I �� I I �� I I 273e 8r1 2e WEST ELEVATION RESUB Mar 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U z N Z o a � � Y= rn wa•�, ��a "� O °' J� U �m� M CO � Z � N C W � �� � o �' W m � o W a F +-= O 'f���,,✓'I Ig U � + �� 'tl � � �� � . �. Q) L ,- .1 ;� Zy.0. C L y d � N C C E C O O o Z J p� o � O t �= � (0 (Op N O N� d O C Nam C �V :. O L H p T j L U E y y 2�a c c m�~���� n�-�a`� O J y m C O O_ @ t6 O� (0 N O .t.. � U LL �� r C N O L� Q~ '= � 10 C E N O W� U£ O U Co U EO p C C� ?� ��N N U UJ J— y U a0O 0.O •-�-0 N � O H C {p y O. (6 � � Z a O�� N N N� O� E� N W Z W /� W pC z W ZW W W W � � � � � W �_ uJ O J 0 0 .� .� 0 z PROJECT NO. 200305 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 9/20/2020 2:32:57 PM SYM. N0. WIDTH DOOR SCHEDULE -MAIN HEIGHT DOOR TYPE FLOOR COMMENTS MAIN FLOOR D1 16' - 0" 9' - 0" OVERHEAD GARAGE DOOR INSULATED STEEL GARAGE DOOR D2 12' - 0" 14' - 0" OVERHEAD GARAGE DOOR INSULATED STEEL GARAGE DOOR D3 9' - 0" 9' - 0" OVERHEAD GARAGE DOOR INSULATED STEEL GARAGE DOOR D4 3' - 0" 8' - 0" SINGLE ENTRY EXTERIOR INSULATED FIBERGLASS ENTRY -DOOR D5 3' - 0" 8' - 0" SINGLE ENTRY EXTERIOR INSULATED FIBERGLASS ENTRY -DOOR D6 2' - 8" 8' - 0" SINGLE PANEL D7 2' - 8" 8' - 0" SINGLE PANEL 1 3/8" SOLID CORE w/ SELF CLOSING MECHANISM D8 2' - 6" 8' - 0" SINGLE PANEL SYM. N0. WIDTH WINDOW SCHEDULE -MAIN HEIGHT AREA WINDOW TYPE FLOOR U-VALUE MAIN FLOOR 1 3' - 0" 5' - 0" 15 SF SINGLE HUNG 0.30 2 3' - 0" 5' - 0" 15 SF SINGLE HUNG 0.30 3 2' - 0" 2' - 6" 5 SF PICTURE (FIXED) 0.30 4 2' - 0" 2' - 6" 5 SF PICTURE (FIXED) 0.30 5 2' - 0" 2' - 6" 5 SF PICTURE (FIXED) 0.30 Grand total 45 SF KEY VALUE KEYNOTE SCHELDULE TEXT COMMENTS 01 GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE DOOR OR EQUIV. 20 MIN. RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH ASELF-CLOSING DEVICE. (R302.5.1) 02 LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 03 GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 &TABLE 302.6) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503) 06 GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) 07 STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6) 08 EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) 10 DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 12 PILOTS, BURNERS, &SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. 14 ATTIC ACCESS: MIN. 22"X30" AND REQUIRED AT AREAS GREATER THAN 30 SQ. FT. AND VERTICAL HEIGHT OF 30" OR GREATER. (R807.1) SEE M1305.1.3 FOR ADDITIONAL REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. 18 CLOSET SHELVING AND DRAWER ORGANIZERS PER BUILDER SPECS. 19 TEMP. GLASS DOOR 20 TEMP. GLASS WINDOW 24 FIBERGLASS TUB w/TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFCATIONS. 25 PANTRY SHELVING: PROVIDE (5) MELAMINE OR EQUIV. 16" DEEP SHELVES PER BUILDER SPECIFICATIONS. 27 1/2" GWB UNDER STAIRWAY IN ENCLOSED SPACES. O 0 0 Q w z CO HANDRAIL, GUARD AND BALUSTERS TO CONFORM TO I.R.C. OPENINGS SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. i N c%� z O � W �� M 3/4" MIN; 1 1 /4" MAX. NOSING 10" MIN. TREAD RESIDENTIAL STAIRS TO BE MIN. 36" (CLR) WIDE. - 1 1/4" DIA. MIN; 2" DIA. MAX. HANDRAIL w/ RETURNS TO WALL. -- TRIANGLE OF STEPS TO RAIL OPENING SPACED SUCH THAT A � 6" SPHERE CANNOT PASS THRU. II II II I I II II II FIRE BLOCK BETWEEN STUD \ BAYS AT WALLS IN CONTACT �� WITH STRINGERS. 1/2" MIN. PLYWOOD RISERS STAIR DETIAL DBL. JOIST (U.N.O.IN PLAN) SIMPSON LUS210 JOIST HANGER - SIMPSON A35 EACH SIDE OF STRINGERS - (1) LAYER 1/2" GWB -- 2x12 STRINGERS PER PLAN 5 3 2 1 0 0 M I U (2� I I I I 4'-111/2" 4'-0" 4'-0" 5'-41/2" 3'-3" 16'-0" 18'-0" 16'-0" 50'-0" MAIN FLOOR RESUB Mar 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U Z N O Z a � a �� � Y= rn wa•�, ��a "� O °' J� U �m� M CO � Z � N C W � �� � o �' W m � o W a F +»�= 0 %r �� ,� a` r, µ; .y / �� a� tli 1�: C L �� � i �� �i� � ... _ z `�� � j � �r � a i I � � .�';.fi���i Zy.0. C L y d � N C C E C O O J � '� C O T �}� r (n N N 3 a y N� o Z J p U CO C O L �= � (0 N N O N� d O C Nam C .0 :: O L H p T j L U E y y 2�a c c m�~���� n�-�a`� O J y p, C O O_ @ t6 O� (0 N O .t.. � U lL o. �� 0. C N O L� Q '= � 10 C E N O W� U£ O U Co U EO p C C� ?� ��N N U UJ J— y U a0O 0.0 •-�-0 N � O H C {p y O. (6 � � Z a O�� N N N� O� E� N W W /� W W ZW W J u� W � J � J � W �_ uJ O c 0 .� .� O Z PROJECT NO. 200305 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 9/20/2020 2:33:16 PM DOOR SCHEDULE - 2ND FLOOR SYM. N0. WIDTH HEIGHT DOOR TYPE COMMENTS 2ND FLOOR D9 2' - 6" 6' - 8" SINGLE PANEL D10 2' - 8" 6' - 8" SINGLE PANEL D11 2' - 8" 6' - 8" SINGLE PANEL D12 6' - 0" 8' - 0" BI-PASS CLOSET DOOR D13 2' - 6" 6' - 8" SINGLE PANEL D14 2' - 6" 6' - 8" SINGLE PANEL D15 6' - 0" 7' - 0" DOUBLE GLASS (TEMP.) TEMP. GLASS (U=0.30) D16 2' - 6" 6' - 8" SINGLE POCKET D17 5' - 0" 6' - 8" DOUBLE PANEL WINDOW SCHEDULE - 2ND FLOOR SYM. N0. WIDTH HEIGHT AREA WINDOW TYPE U-VALUE COMMENTS 2ND FLOOR 6 8' - 0" 4' - 0" 32 SF DOUBLE SLIDER 0.30 7 2' - 6" 5' - 0" 13 SF SINGLE HUNG 0.30 T .GLASS 8 2' - 6" 5' - 0" 13 SF SINGLE HUNG 0.30 EMP. SS 9 2' - 6" 4' - 0" 10 SF CASEMENT -SINGLE 0.30 EGRESS CASEMENT w/MIN. 90 DEG. FULL SWING 10 2' - 6" 4' - 0" 10 SF CASEMENT -SINGLE 0.30 EGRESS CASEMENT w/MIN. 90 DEG. FULL SWING 11 2' - 6" 4' - 0" 10 SF CASEMENT -SINGLE 0.30 EGRESS CASEMENT w/ MIN. 90 DEG. FULL SWING 12 3' - 0" 4' - 0" 12 SF PICTURE (FIXED) 0.30 13 3' - 0" 4' - 0" 12 SF PICTURE (FIXED) 0.30 14 3' - 0" 4' - 0" 12 SF PICTURE (FIXED) 0.30 15 3' - 0" 4' - 0" 12 SF SINGLE HUNG 0.30 TEMP. GLASS Grand total 135 SF KEYNOTE SCHELDULE KEY VALUE TEXT 01 GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE DOOR OR EQUIV. 20 MIN. RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH ASELF-CLOSING DEVICE. (R302.5.1) 02 LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 03 GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 &TABLE 302.6) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503) 06 GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) 07 STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6) 08 EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) 10 DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) 11 TYPICAL EXTERIOR WALL: SIDING o/INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 12 PILOTS, BURNERS, &SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. 14 ATTIC ACCESS: MIN. 22"X30" AND REQUIRED AT AREAS GREATER THAN 30 SQ. FT. AND VERTICAL HEIGHT OF 30" OR GREATER. (R807.1) SEE M1305.1.3 FOR ADDITIONAL REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. 18 CLOSET SHELVING AND DRAWER ORGANIZERS PER BUILDER SPECS. 19 TEMP. GLASS DOOR 20 TEMP. GLASS WINDOW 24 FIBERGLASS TUB w/TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFCATIONS. 25 PANTRY SHELVING: PROVIDE (5) MELAMINE OR EQUIV. 16" DEEP SHELVES PER BUILDER SPECIFICATIONS. 27 1/2" GWB UNDER STAIRWAY IN ENCLOSED SPACES. 6 0 -v 5 - M o , 0 <V 0 O p0 N (V co 0 B C D E F G 36' - 0" 2'-0" 6'-51/2" 4'-4" 15'-1" 6'-11/2" 2'-0" 3'-6" 3'-6" '-51/2" SHELF OVER 1' - 11 1/2"- FURRED OUT 11 WALL BELOW � 15 14 � 12 13 � � � � � � — — — — �— STORAGE/ � COAT 2 I I I I I I I I I I I I I I N I I I I I I I I I I I I 1 CLOSET D9 2Q A5 I I I I I I I I I I I I I I I I 1 �� A7 = I I I I I I I I I I I I I II 1 1- 4 � I A] �, 0 07 I I I I I I HANDRAIL I I I I I I I � � � � �. _�. � � ' � , 20 � 42" TALL HALF Og � o a p.W� � � � � � �� _ � O - � WALL w/WOOD i �- FULL HEIGHT � � CAP AND TRIM - i WALL FOR UPPER � �, A2 , ,- N I CABINET BACKING �; -� � � � �� -- DUCTLESS MIN -SPLIT � I 02 D1� CEILING HEAD. � � � � � ��_ O� _ 04 � PATIO �� �. � �� � �� � � I � � i -� ��� � � � � ;III �° LIVING RM. KITCHEN ATTIC � _ I I � �- 19 � I I� I I AccEss FROM I I I I 1� �� � �I I FLOOR BELOW � 1 �. ��' AH „ � � � �� STACKED � � Q � � AH WASHER/DRYER - w a � ,_. ,".. 0_ �� � I D 7 80 CFM 20 11 � � N 10 V.T.O. 18 3, _ 9„ 25 - � - � � � � _ — -SPLIT � DUCTLESS MINI 10'-0" _ _ _ � I � CEILING HEAD. o � • � .o. S.D. � - � , CLOSET �. D10 � D11 �. 10 `"' `�' � 2' - 2" 6' - 11 1 /2" 8' - 1 1 /2" D12 I 08 EGRESS CASEMENT _ 10' - 6" 3' - 9" D14 � w/ 90 DEG. OPENING. � TIMER CONTROLS I � I - I I - I I 9 - 1 08 _ BEDR OM 2 - 'I <V A9 �- 180 CFM WHOLE HOUSE � I I � A9 l � FAN WITH TIMER (V.T.O.) 1 � � � � N II MASTER SUITE D1s BAT 14'-4° LJ 11 � "' �I 6-8 8-11/2 i I 1' - 10" � o 1 i II I O A TIC ACCESS � A2 DUCTLESS MINI -SPLIT D13 I M - MINI -SPLIT CEILING HEAD. I �� 'I � HEAT PUMP UNIT I i �X'' II � � (LOCATION MAY VARY � i I �' �� I 18 0 . o I �'---- � 14 I M PER OWNER SPECS.) � `V W.I.C. I � � --- — I— 03 24 0' - 11" 03 16'-0" 14'-81/2" 5'-7" 6'-8" 8'-11/2" � I R.V. GARAG� BELOW i�i i�i i� O � � � "' 16'-0" I 36'-0" �— — — — —�— — — — —I�— — —�- 1 � L-!------------! --- 2ND FLOOR RESUB Mar 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U z N a0 O W z Q ,_ a �� � Y= rn wa•�, ��a "� O °' J� U �m� M CO � Z � N C W � �� � o �' W m � o W a F `T=� . O ��,y ,�i �� ,� '� ,"1't�` �` r C + '� �I� `� G� ii �I �' iii� �� I�-' � ,�ii�.l �a k�. �;r �'��fi�''i z ����° ��=���oa C �}� r (n (� N 3 J" oZ� o u o �Ot'=a o N E a a� N Q m� v°�i o a�i 10 n wam o.��� o�H =�Q�a �-�a'�c—mom c�•�a�.V £ y c o `o��o'� O J N O) C 0 0— @ t6 O� (0 N O U LL r �� C .t.. � r N O L� Q '= � 10 C E N O W� U £ O U o Co U p p C C� ?� � �N !Ub U UJ J— N 4� U— � C l0 U y 0 O r—O `""O O. a N f` N O Z ao �� � aEi m � o� E � d W W /� W W Z W W J W W �_ W �_ uJ O J Q N N CV C O .� .� O ,_ .� w 0 Z PROJECT NO. 200305 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 2/24/2021 1:04:17 PM B C D E F G I I I I 2'-0" 13'-0" I 12'-10%" 6'-1Y" I 5'-0" I I I I I I I I I I I I I I I I I I 12 12 I MFG TRUSSES 9� I � 9 I I I I I BEAM PER SCHEDULE I I I I I I I I I I I I I ATTIC I I I I I I R-38 HIGH DENSITY BATT INSUL. I I I (HEATED AREAS ONLY) ROOFING PER ELEVATIONS I I I I I I of 30# FELT OVER �/6"APA 1"AIR SPACE w/ CARDBOARD RATED 24/16 SHEATHING ON - BAFFLE. EXTEND 24" ABOVE RAFTERS PER PLAN I � I I INSULATION I I I 1"AIR SPACE � FRAMING MEMBER ATTACHED TO I I I TOP PLATES PER STRUCTURAL I I I R-38 HIGH DENSITY BATT INSUL. (HEATED AREAS ONLY) BLOCKING I I I I I 2ND PLATE I — — — — — — — I — — — — — — — — � — I — � NT BLOCKS w/ (3) 2"dia. WIRE SCREENED VENTHOLES @ EA. BLOCK I I I I I BLOCKING FRAMING MEMBER ATTACHED TO I I I I TOP PLATES PER STRUCTURAL I I I I RV BAY PLATE � I I I I (2) 2x6 TOP PLATES ROOFING PER ELEVATIONS STAGGER JOINT MIN. 48"O.C' o/ 30# FELT OVER %6"APA I I I 2x6 STUDS @16" O.C. RATED 24/16 SHEATHING ON (U.N.O. IN STRUCTURAL) MANUF. TRU E PER PLAN I I I I EXTERIOR FINISH PER ELEVATION o/ 12 VENT BLOCKS w/ (3) 2"dia. WIRE 15# BUILDING PAPER OR i � 5 @ REENED VENTH LE EA. APPROVED AIR INFILTRATION I I I I I BLOCK BARRIER o/SHEATHING PER STRUCTURAL PLANS. I SOFFIT PER ELEVATIONS I I I I I R-21 BATT INSULATION _ i 3/4" T&G PLY OR EQUIV. SUB -FLOOR ATTIC CONT. ALUM. GUTTER ON FASCIA (HEATED AREAS ONLY) � GLUED &NAILED TO 2x6 BASE PLATE BOARD PER ELEVATIONS CAULKING/ SEALANT BEAD � � 18"OPEN WEB FLOOR TRUSSES PER I %" GYPSUM WALL BOARD I � I STRUCTURAL. w/APPROVED AT FLOOR PERIMETER P.V.A. VAPOR RETARDER I I I I 2x6 BASE PLATE I 2ND FLOOR I BEAM PER SCHEDULE - P.T. 2x6 BASE PLATE w/ I I � r' ANCHOR BOLTS PER `° � SHEAR WALL SCHEDULE. I � ,p_ I I MAIN PLATE _ _ _ I � _ _ _ I _ _ _ _ _ I _ I I HANGER PER TRUSS MFG. I I 4" TIGHTLINE DRAIN WHERE REO'D FRAMING MEMBER ATTACHED TO a %2' GYPSUM CEILING BOARD R-21 BATT INSULATION BEAM PER STRUCTURAL (2) 2x4 TOP PLATES STAGGER JOINT MIN. 48"O.C. (HEATED AREAS ONLY) I I R-49 BATT OR BLOWN INSUL. 2" RIGID R-10 INSULATION BEAM PER SCHEDULE Yz" GYPSUM CEILING BOARD I � I (HEATED AREAS ONLY) I i I I INSTALLED IN CAVITY BETWEEN HEADER &INTERIOR R-21 BATT INSULATION I I G.W.B. � I I (HEATED AREAS ONLY) dd ' HEADER PER STRUCTURAL 2" SPACE I I I I I 2x4 STUDS @16" O.C. I I I I I I %" GYPSUM WALL BOARD w/APPROVED P.V.A. VAPOR RETARDER I a< I I I I I FOUNDATION WALL SIZE AND REINFORCING PER STRUCTURAL I I I I I PLANS I I I I I I 4" CONC. SLAB o/ 2" RIGID INSUL. w/ THERMAL BRAKE o/ COMPACTED GRANULAR FILL I I I I I I P.T. 2x4 BASE PLATE I I I I I I FOOTING SIZE AND REINFORCING PER STRUCTURAL PLANS. I d a I I I I I 4" PERF. FT'G DRAIN.WRAP IN FILTER FABRIC wl GRAVEL OVER. I � I I I I I MAIN FLOOR d a a a d a c a s d a a � d a a n a a d a � � 4 da d a I I � d l e a ° d d �/'. d a \ ad \� A I I I d l I I a a O r// 1 BUILDING SECTION '' A7 SCALE: 1/2" = 1'-0" RESUB - - Mar 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT S I I I I I x GER JOINT MIN. 48"O.C. MFG TRUSSES 2x6 STUDS @16" O.C. U.N.O. IN STRUCTURAL) U z � N M O 00 Q � U Y 2 0� J Wd�u7 W � N GS � C "� O J � � U ��� M CO w Z � N C N — N W m � d LJJ F�- O .$ V . i C �� �_ � 1 � !��� G `I�jiIIIIII!Iflllllllll(k r Illl'��II� � L �... I � �a� � ' 1 i � � a ,� .l -'_.� � °'fi�� I U LLj d °3 �` g` i -° m a c o m o 0 Z U E U1 .N - U d W C @ U C w« ~�� d � N `1 � C C C U� O� y p = O J N- "O N� a N @@ O�- L N j � V m N u @ .L. @ E U1 O y �` C@ C ._ � Z Q vS y N (� N N a1 � N y p C a W J p U7 C N C C@ � «O .p- N O. - U U � O o p� :.. O d a o 5— U« a WFna'-o d�o.a@�o�vt � � � w N � t aEi m � > � E m m ccOi J Q � H O W W I� W � 0 � W Z Q W � uT, i Z LJJ � o W m �_ W � J :� c r a �L v 0 Z PROJECT NO. 200305 TL DESIGNED BY DRAWN BY TL & RM CHECKED BY TL SHEET: PRINT DATE 9/2/2020 10:20 AM 1 BUILDING SECTION � A8 SCALE: 1/2" = 1'-0" RESUB Mar 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U z � N M O 00 Q � U Y 2 0� J W d 'u7 W � N GS � C "� O J � � U ��� M CO w Z � N C N — N W m � d LLJ F— O .$ V . i C �� �_ � 1 � � ,,�� C `�'�i�IIIII!Ifl�lllllll(k -+ 'lll'i�I� � �... I � .� �� l `� v,-,` �'1�;���� U LLj d °3 �` o i v m a c o m o 0 Z U E U1 .N - U d W C @ U C w« ~�� d � N `1 � C C C U� O� y p = O J N- "O N� a N @@ O�- L N j � V m N u @ .L. @ E U1 O y �` C@ C ._ � Z Q vS y N (� N _N a1 � N y p C a W J �� C N C C O � «O fN, N 0.- U U � O o p� :.. O d a o 5— U« a wF na'-o d�o"a@�o�v t? � � � w N � t aEi m � > � E m m c�0i J Q � H O W Z W 0 t,I� W � � z � � W Z � Q W � u, � _ � z LJJ � o — � � � o � � m W �_ W � J w 0 0 r a �L :.: 0 0 Z PROJECT NO. 200305 TL DESIGNED BY DRAWN BY TL & RM CHECKED BY TL SHEET: PRINT DATE 9/2/2020 10:20 AM 1 BUILDING SECTION A9/ SCALE: 1/2" = 1'-0" RESUB Mar 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U z � N M O 00 Q � U Y 2 0� J W d 'u7 W � N GS � C "� O J � � U ��� M CO w Z � N C N — N W m � d LLJ F— O .$ V . i C �� �_ � � ,,�� C `i'�i�IIIII!Ifl�lllllll(k •�� 'lll'i�I� � �... I � .� l: o,..�. •I N N U W N d �` O= -O � a C O N O O Z U £ N .N - U d W C @ U C w �} H O 'O U N b O L @ �, O. N C O ~�� d � N d � C C C U� O� y p = O J N- "O N� a N @@ O�- L N j � U m N u @ .L. @ E U1 O y �` C@ C ._ � Z Q vS y N (� N _N a1 � N y p C a W J p U7 C N C C O � «O fN, N 0.- U U � O o p� :.. O d a o 5— p« a H�� N� �� z d m�>� E m m J Q � H O W Z W 0 t,I� W � � z � � W Z � Q W � u, � _ � z LJJ � o — � � � o � � m W �_ W � J w 0 0 r a �L :.: 0 0 Z PROJECT NO. 200305 TL DESIGNED BY DRAWN BY TL & RM CHECKED BY TL SHEET: PRINT DATE 9/2/2020 10:20 AM GENERAL NOTES WOOD All design and construction shall conform to the requirements of the International Building Code 2015 Edition. Contractor shall verify all levels, dimensions and existing conditions in field before proceeding with any construction or demolition. Contractor shall notify the Architect of any discrepancies or field changes Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work. Contractor shall provide adequate shoring and bracing of all structural members, existing construction and soil excavations as required, in a manner suitable to the work sequence. Temporary shoring and bracing shall not be removed until all final connections have been completed in accordance with the drawings and materials have achieved design strength. Foundations walls greater than 4 feet shall not be backfilled until the floor framing and all connections to the floor framing per these details are complete. CHANGES: No changes to these structural drawings are permitted without written consent of the Engineer. Changes will be billed to the client, owner or contractor at the Engineer's hourly rate. SUBMITTALS: Shop drawings shall be submitted to the Architect prior to any fabrication or construction for all the following: Structural steel, steel canopies, glued -laminated members and pre -manufactured wood members. Design drawings and calculations, for pre -manufactured wood trusses and joists shall bear the seal and signature of the Washington State Registered Professional Engineer who is responsible for the design, and shall be submitted to the Architect and Building official for review prior to fabrication. DESIGN LOADS LIVE LOADS: Live loads are determined in accordance with ASCE Ch. 7 L = 40 PSF (Residential) SNOW LOADS: Snow loads are determined in accordance with ASCE Ch. 7 with the following Factors: Ground Snow Load Pg = 20 psf Ct = 1.0 Ce = 1.0 Roof Snow Load Ps = 25 psf Is = 1.0 WIND LOADS: Wind loads are based on ASCE 7-10 Ch. 28 (Envelope Procedure) with the following factors: Exposure Category = B Iw = 1.0 Velocity (3 sec) =110 mph (ult) Kzt = 1.0 Design wind pressured for determining forces on components and cladding are determined in accordance with ASCE 7-10 Chapter 30. SEISMIC LOADS: Seismic loads are based on the Equivalent Lateral Force Procedure in ASCE 7-10 Section 12.8 with the following factors: Risk Category = II Ss = 1.30 Site Class = D S1 = 0.500 Design Category = D SDS = 0.867 R = 6.5 (wood shear wall) SD1 = 0.500 Ie = 1.0 Cs = 0.133 (ult.) HORIZONTAL EARTH LOADS: Horizontal soil loads used for design of retaining walls and basement walls are based on assumed soil values typical of this region: Active Pressure (Restrained) -55 pcf (EFP) Active Pressure (Unrestrained) -35 pcf (EFP) Passive Pressure -250 pcf (EFP) Coefficient of friction -0.4 FOUNDATIONS Concrete foundations shall bear on stiff, competent, undisturbed native soil. Prior to construction, the contractor shall obtain confirmation from the Building Official that the native soil at this project is adequate to support the following bearing pressure: Allowable bearing pressure used for structural design = 2000 psf (assumed) Where footings must bear on structural fill due to inadequate soil conditions, the fill shall be mixed and compacted in accordance with specifications provided by a Geotechnical Engineer licensed in the State of Washington. Bottom of footing elevation shall be located at minimum frost depth 18" below top of finished grade unless required otherwise by the Building Official. The contractor shall confirm the minimum frost depth with the Building Official prior to excavation. CONCRETE Concrete work shall comply, in general, with ACI 301 (latest edition) "Specifications for Structural Concrete for Buildings." CONCRETE MIXES: Concrete mixes shall conform ACI 318 Ch. 5. Minimum concrete strength f'c at 28 days shall be as follows: Slab -on -grade, Curbs and Pads - 2000 psi Footings - 2500 psi Walls, Stems - 3000 psi (2500 psi used for structural design) Water/cement ratio shall be measured by weight and shall be based on the total cementitious material. Water/cement ratio shall be determined by the supplier based on strength requirements and shall not exceed 0.55. Water -reducing admixtures may be incorporated in concrete mix designs but shall conform to ASTM C 464, and be used in accordance with the manufacturer's recommendations. CaCI and other water -solvable chloride admixtures shall not be used. REINFORCING STEEL: All reinforcing shall be deformed bar (rebar) with bar diameters specified in these drawings and properties below: All reinforcing unless noted otherwise - ASTM A615, Grade 60 #3 stirrups and ties - ASTM A615, Grade 40 Welded rebar - ASTM A706, Grade 60 Galvanized Welded Wire Fabric - ASTM A165 Reinforcing steel shall be detailed in accordance with ACI 315 "Manual of Standard Practice for Detailing Reinforced Concrete Structures." Reinforcing steel shall be lapped as noted on the drawings. Where lap length is not shown, reinforcing bars shall be lapped as follows: #5 and smaller - 48 bar diameters #6 and larger - 60 bar diameters Minimum concrete cover over reinforcing shall be as follows: Nonstructural Slab -on -grade - Mid -Depth Wall Bars: interior face - 3/4" exposed to earth/weather - 1-1/2" (#5 and smaller) 2" (#6 and larger) Footings: Bottom Bars - 3" (cast against earth) Top Bars - 1-1/2" Side Bars - 2" Provide supports as required for proper alignment and concrete cover around the reinforcement. Consult the CRSI Manual of Standard Practice MSP-1 for specific information. SAWN LUMBER: Structural sawn lumber shall be kiln dried and be of the species and grade noted below or better: Use Grade Fb si Wall Studs Stud 675 Plates &Planks Hem Fir #2 850 Joists &Rafters Hem Fir #2 850 4x Beams Douglas Fir -Larch #2 900 6x Beams Douglas Fir -Larch #2 875 Posts Douglas Fir -Larch #2 750 2x4 T&G Decking Douglas Fir -Larch Select 1750 All lumber and plywood exposed to weather or water or in contact with concrete, stucco, masonry or other cementitious materials shall be treated with an E.P.A. acceptable wood preservative, such as Alkaline -Copper -Quaternary "ACQ" or Copper Azole "CBA" type A and B. All wood connectors shall be manufactured by Simpson Strong Tie Company (or approved equal), and of the size and type shown on the drawings. All wood connectors in contact with preservative -treated wood shall be Triple Zinc G-185 galvanized (1.85 oz/sq ft coating). MINIMUM WOOD NAILING REQUIREMENTS: Unless otherwise noted on the drawings, typical wood framing shall be fastened as follows. See IBC Table 2304.10.1 for fastener alternatives not shown. Location Min. Nail Quantity/Spacing Type* Beams (built up 2x's) 3" x 0.131" 24" o.c. T&B* FN EF* staggered Blocking -to joists, rafters, trusses 3" x 0.131" 2 each end TN or studs -to top plates 3" x 0.131" 3 TN Bottom plate -to joist, rim joist 3" x 0.131" 12" o.c. FN or blocking -to studs 3" x 0.131" 3 EN Header (built up 2x's) 16d box 12" o.c. T&B FN Header -to studs 3" x 0.131" 4 TN Joist -to supports 3" x 0.131" 3 TN -to rim joist 3" x 0.131" 4 EN Rafter -to supports 3" x 0.131" 4 TN, EN Rim Joist -to sill or blocking 3" x 0.131" 6" o.c. TN Stud -to Stud 3" x 0.131" 12" o.c. FN -to top/bottom plate 3" x 0.131" 4 TN Top plate -to top plate 3" x 0.131" 12" o.c. FN -to studs 3" x 0.131" 3 EN -laps at corners and 3" x 0.131" 3 FN intersections Truss to top plate 3" x 0.131" 4 TN *EN =end nail, FN =face nail, TN =toe nail, EF = "each face", T&B = "top and bottom" RATED SHEATHING: Wood structural panels shall bear the APA trademark of the American Plywood Association. Sheathing shall be as follows: Shear Wall Shtg 7/16" 32/16 C-D INT APA with Exterior Glue (CDX) Roof Shtg 15/32" 32/16 C-D INT APA with Exterior Glue (CDX) Sub Floor Shtg 3/4" 48/24 T&G C-D INT APA with Exterior Glue Sheathing shall be orientated over the supports as shown on the drawings. Shear wall sheathing shall be blocked at all panel edges as shown in the shear wall schedule. GLUED LAMINATED MEMBERS: Glued Laminated members shall each bear an AITC identification mark and be accompanied by an AITC certificate of conformance. One coat of end sealer shall be applied immediately after trimming either shop or field. Members shall be Visual Graded Western Species Inductrual, Architectural or Premium grade with strength as follows: Symbol Species Fb E GLB 24F-V4 DF/DF 2400/1850 psi 1,800,000 psi GLB 24F-V8 DF/DF 2400/2400 psi 1,800,000 psi ENGINEERED COMPOSITE LUMBER: Engineered Composite Lumber shall be manufactured by Trus-Joist, Boise Cascade or approved equal and shall have the following minimum strength (based on 12" member depth): Symbol Fb E PSL 2900 psi 2,000,000 psi LVL 2600 psi 2,000,000 psi LSL 1700 psi 1,300,000 psi Versa -Lam (1%4-2%") 2800 psi 2,000,000 psi VersalLam (3%" &wider) 3100 psi 2,000,000 psi PREMANUFACTURED OPEN WEB WOOD TRUSSES: Trusses shall be design by a Structural Engineer licensed in the State of Washington, who is regularly engaged in the design of plate -connected wood trusses. Truss design shall be accordance with IBC Section 2303.4. Trusses shall be design for the following dead loads: top chord bottom chord total roof trusses 10 psf 5 psf 15 psf floor trusses 12 psf 3 psf 15 psf In addition to dead loads, the design shall include the live, wind, snow loads as identified in the "Design Loads" section of these drawings, and the snow drift, sliding and unbalanced loads per ASCE7 Chapter 7. The truss design shall include concentrated and axial loads shown on framing plans and hanger schedules in these drawings. Roof trusses shall be designed for wind net uplift of 10 psf unless otherwise noted on the drawings. Floor trusses shall be design for maximum live load deflection = 1/2" and minimum live load deflection ratio = L/480. Trusses shall be fabricated by a manufacturer who is a member of the Truss Plate Institute. Trusses shall be supplied with the proper hangers, end connections, bridging, bracing to provide lateral stability of all truss members, and tie -down connections to beams and tops of walls. Trusses shall be supplied with tapered hardwood shimming so that every chord bears on the full width of every support, without notching the truss members. The truss manufacturer is responsible for ensuring the bearing seat does not exceed the sill plate capacity of the supporting element. RECOMMENDED INSPECTIONS The following recommended minimum items shall be inspected by a qualified individual provided by the Building Official: -Footings bear on competent native soil per the "Foundations" section above -Footing reinforcement -Shear wall sill plate anchors and washers per schedule -Shear wall nailing and shear clips per schedule -Shear wall hold-downs -YPICAL DETAILS � addition to the details and schedules on the framing plans, those noted as "Typical" shall be sed throughout the structure as applicable. STRUCTURAL NOTES c� x _� J - J Q Y U a m SHEAR WALL PER PLAN PT SILL PLATE w/ANCHOR BOLTS AND WASHERS PER SHEAR WALL PLAN AND SCHEDULE. EMBED = 7" MIN. x z � � °r,° PERFORATED FTG. DRAIN CON'T. M SEE 8/S1 AND 9/S1 FOR FOUNDATIONS GREATER THAN 4 FT CONCRETE SLAB ON GRADE PER PLAN. ELEVATION MAY VARY. SEE ARCHITECTURAL FOR INSULATION REQUIREMENTS WHERE APPLICABLE. #4 HORIZ. AT 18" o.c. AND (2) AT TOP OF WALL #4 VERT. DOWELS AT 18" o.c. ALTERNATE HOOK AT BOTTOM FOOTING PER PLAN SINGLE REINFORCING NOTES: 1. VERTICAL REINFORCING NOT SHOWN FOR CLARITY 2. SEE STRUCTURAL NOTES FOR CLEAR COVER 24" #4 x 24" MATCH HORIZ REINF. 24" #4 x 24" MATCH HORIZ REINF. #4 x 24" MATCH HORIZ REINF. DOUBLE REINFORCING TYPICAL CONCRETE FOUNDATION � 1 � TYPICAL CONCRETE WALL AND FOOTING CORNER � 2 FLOOR BOUNDARY NAILING 2x8 PT SILL PLATE WITH 5/" DIA. x7" SHEAR WALL PER PLAN. EMBED ANCHOR BOLTS AT 24" o.c. MOISTURE BARRIER AT TRUSS ENDS ,, NOTCH TRUSS OVER LEDGER TOP OF TRUSS r; TOP OF CONCRETE �. � �FLOOR TRUSSES PER PLAN DBL 2x10 LEDGER (PT AGAINST VERTICAL AND CONC.) WITH THD62612 AT 19.2" o.c HORIZONTAL STAGGERED TOP AND BOTTOM. NAIL REINFORCING PER 9/S1 TOGETHER WITH 10d AT 4" o.c. TOP AND BOTTOM. DRAINAGE MATT FULL HEIGHT OF WALL 2" CLR. +1/4", -( 8" THICK CONCRETE WALL JOISTS PERPENDICULAR TO WALL PER 9/S1 GRADE PER PLAN f4 VERT AT END OF WALL f4 CONT. AT TOP OF WALL CONCRETE FOUNDATION WALL PER PLAN (TYPICAL REINFORCING NOT SHOWN FOR CLARITY TYPICAL CONCRETE WALL STEP I 1 O �n TOP OF TRUSS ri TOP OF CONCRETE VERTICAL AND HORIZONTAL REINFORCING PER 9/S1 DRAINAGE MATT FULL HEIGHT OF WALL w a 2" CLR. J LL -� ]C O U a m 12" THICK LAYER OF FREE -DRAINING GRAVEL FULL HEIGHT OF WALL a � ^ PERFORATED FOOTING DRAIN FOOTING PER 9/S1 FLOOR BOUNDARY NAILING 2x8 PT SILL PLATE WITH %" DIA. x7" EMBED ANCHOR BOLTS AT 24" o.c. 10d AT 4" o.c. TO BLOCKING � FLOOR TRUSSES PER PLAN 2x FLAT BLOCKING AT 24" o.c. 8" THICK CONCRETE WALL (3) #4 VERT. DOWELS FOOTING PER PLAN TYPICAL EXTERIOR ISOLATED FOOTING � $ CANTILEVERED RETAINING WALL SCHEDULE BACKFILL HEIGHT "HEEL" "TOE" "FTG DEPTH" VERT. REINF. TRANS. REINF. LAP 3'-0" MAX SEE TYPICAL FOUNDATION SECTION 4'-0" MAX 12" 12" 10" #4 @ 18" o.c. NA 20" 5'-0" MAX 16" 14" 10" #4 @ 18" o.c. #4 @ 36" o.c. 20" 6'-0" MAX 22" 14" 10" #4 @ 15" o.c. #4 @ 30" o.c. 24" 7'-0" MAX 30" 14" 10" #4 @ 12" o.c. #5 @ 18" o.c. 24" 8'-0" MAX 42" 14" 12" #5 @ 12" o.c. #5 @ 18" o.c. 30" 9'-0" MAX 54" 14" 12" #5 @ 10" o.c. #5 @ 15" o.c. 36" 10'-0" MA 66" 14" 13" #6 @ 10" o.c. #5 @ 12" o.c. 36" D SILL DR WALL ;" DIA. WITH IASHER :ATED). o.c. AND LL > PER w a 8" _� <. J = • � DOWELS MATCH VERT. � DOWELS PER 9/51 � � 2" CLR. BARS. LAP PER m (+1/4", -0") SCHEDULE. ALTERNATE HOOK. d�� TDAAIC orini� _ `I � SLAB ON GRADE PER PLAN a �' JOISTS PARALLEL TO WALL SLAB ON GRADE PER PLAN FULL HEIGHT RETAINING WALLS � $ "' v FOOTING�PER�PLAN THICKENED SLAB FOOTING AT POST I 1 1 CANTILEVERED RETAINING WALLS 9 HOLD-DOWN ANCHOR SCHEDULE HOLD-DOWN ANCHOR IN CONC. STEM WALL ANCHOR IN THICKENED SLAB FLOOR TO FLOOR ANCHOR 1 HDU4 SB % x 24 PABS x 6" EMBED %$" DIA. HDUS SB % x 24 PABS x 6" EMBED %$" DIA. HDU8 SB % x 24 PAB7 x 8�" EMBED %$" DIA. HDU11 SB 1 x 30 PAB8 x 10" EMBED 1" DIA. HDU14 SB 1 x 30 PAB8 x 10" EMBED 1" DIA. NOTES: 1. F1554 THREADED ROD 2. EPDXY ANCHORS SHALL ONLY BE USED WHERE INDICATED ON THE FOUNDATION PLAN w 0 m �j�// � \\ W �//� .. ANCHOR TYPE HOLD-DOWN PER SQUASH BLKG MATCH POST SIZI -ANCHOR PER SCHEDULE ADD #4 x 48" AT EACH ANCH RESUB Mar 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HDU ANCHOR SCHEDULE I 1 Z' Ross Engineering Desig n Inc ryan. ross@rossengineer.com ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN W W /� W O � W Z Q W J i z LJJ � o W m �_ W � J m 0 c 0 a •L N d 0 O Z FILE/ NO. 20058 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: PRINT DATE 9 / 1 / 2020 FOUNDATION NOTES • VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO COMMENCING ANY WORK. • GENERAL CONTRACTOR AND/OR FOUNDATION CONTRACTOR SHALL VERIFY THE LOCATION OF ANCHOR BOLTS AND HOEDOWNS PRIOR TO POURING CONCRETE. • ALL FOOTING SHALL BEAR 18" BELOW UNDISTURBED NATURAL SOIL. FINISHED GRADE SHALL BE NO LESS THAN 12" ABOVE BOTTOM OF FOOTINGS. • TOP OF FOOTING SHALL BE LEVEL. BOTTOM SURFACE OF FOOTING SHALL NOT SLOPE MORE THAN 10%. STEP FOOTING AS NECESSARY TO MAINTAIN MIN. DEPTH OF FOOTING BELOW FINISHED GRADE. • FOUNDATION WALL SHALL EXTEND MINIMUM 6" ABOVE FINISHED GRADE. • ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. • UNLESS NOTED OTHERWISE OR IN SHEAR WALL SCHEDULE, ALL ANCHOR BOLTS SHALL BE%" dia. x 10" AND EXTEND MINIMUM 7" INTO CONCRETE WITH MINIMUM SPACING OF 48" ON CENTER. EACH ANCHOR BOLT SHALL HAVE A 3"x3"x.229" GALVANIZED WASHER. • SEE SHEARWALL &HOEDOWN SCHEDULES FOR SIZE AND PLACEMENT. • CRAWLSPACE ACCESS SHALL BE A MIN. OF 18"x24". OPENINGS THROUGH A PERIMETER WALL SHALL BE NOT LESS THAN 16"x24". (R408.4) • PROVIDE A 6 MIL. BLACK VAPOR BARRIER OVER ALL CRAWLSPACE AREAS. (R406.3.2) • PROVIDE 2" SAND OVER 6 MIL BLACK VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL UNDER ALL CONCRETE SLABS. • PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS ARE IN PLACE. • ALL ISOLATED SPREAD FOOTING TO BE 24"x24"x8" REINFORCE FOOTINGS WITH (2) #4 BARS EACH WAY UNLESS NOTED OTHERWISE IN PLAN. • FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM TOP OF FOOTING TO FINISHED GRADE. (R406.1) • SEE SIMPSON RECOMMENDATIONS FOR HOLD DOWN PLACEMENT. COORDINATE LOCATIONS WITH DOOR &WINDOW ROUGH FRAMING TO PROVIDE ACCURATE DIMENSION FOR OPENINGS. I_1 16'-0" � 2'-0" I �� I I ti _ ill rill � NO INSULATIONI 6 I - -- BETWEEN RETAINING � - WALLAND SLAB TYP o I 1 ��_ A� 5 — I - , I � a 4 1 0 0 M F— 09 I 0 CONCRETE LANDING & STEPS TO GRADE PER I.R.C. 1 �A8 STyd��4 F— 09 1 _ A� E F G i 2'-0" 4'-9%a" F-03 �'� i 10 N I - - I � , l� � _ � 1 o CONCf�ETE LANDINGII& q T STEPS T� GR DE PER I,R.C. `° + iI --- - 6 -4/a �OJ w I �I I � I Q �l -� F-10 w 'I I I "' � I �I I I � I �I I I -- - - l -- - - -I oI I I 1 U F— 05 10" I�I � � � 1 1 ��; � 3 'RAISE STEM WALL PE Sl GARAGED SLAB S1 15/S � I 4" CONC. SLAB. SL PE MIN. 8" F-08 PER 1'-0" TOWARDS G,4RAGE DOORS. I, I, �I I, II II F-10 Q'I I �I I I WI I c� I I zl I I I �I I F-07 I, I I, I, 1�� y0 52'-0" C 32'-0" F— 09 I O--I — � �� �u� R-10 R GID INSUL. - - - -i � - — —F-02 — — I — � C��J \ I�, n----�— I I � ��� - + L� F-04 ,„ v ��� 0 M M M l F 03 Zo .' L �----------� I � 20 �I _� S5 �I, l o �° I I I F-06 II RAISE STEM WALL PEF2 e 15/S 10" ST��7 4 I I I I of I II RV SLAB II II II ¢I II I 4" CONC. SLAB. SLOPE MIN. a" PER 1'-0" TOWARDS GARAGE DOORS. o Z co 0 � N ao (7 i LL i Z I I I I �I I �a I I I 10,. S,��O RAISE STEM WALL PER a L— — — 15/S a .. . . a � . � ... �a I� 0 q � -� - -- - -- - I -� T� -�I- - � - - 0 — — — — — — — — —� I � �` I I I I ST'�47 h� o � � � � O CONCI!�ETE LANIhING & STEPS � o —/ "' F-09 / � � p T� GRADE I�ER LR.C. in �H Z � � 16'-0" 18'-0" 14'-0" 4' IO" 52'-0" � r H NOTE ! ALL FOUNDATION WALLS TO BE 8" UNLESS CALLED OUT OTHERWISE. LEGEND STEM WALL �- FOOTING CONCRETE SLAB CONCRETE FOOTING SCHEDULE SYM. FOOTING SIZE RE -BAR PLACEMENT F—Ol *16"x8" CON'T. (2) #4 CON'T. F-02 16"x12" CON'T. (2) #4 CON'T. F-03 *24"x24"x8" (2) #4 EA. WY. F-04 24"x24"x12" (2) #4 EA. WY. F-05 40"x40"x12" (4) #4 EA. WY. F-06 *44"x44"x8" (4) #4 EA. WY. F-07 *44"x44"x12" (4) #4 EA. WY. F-08 *48"x30"x8" (4) #4 EA. WY. F-09 SEE 9/S1 F-10 *16 x12" THICK CONT. (2) #4 CON'T. TOP AND BOTTOM NOTE: *EXTERIOR FOOTINGS SHALL BE MIN. 18" BELOW GRADE AND REST ON BEARING SOIL. FOUNDATION PLAN SCALE: 1 /4" = 1'-0" RESUB Mar 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Ross Engineering Design Inc ryan. ross@rosseng i neer.com ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN W W /� W � � W ZLJJ Q W J uT, i �7 Z LJJ � o W m �_ W 0 a� 0 c a .� to d O Z PROJECT NO. 200305 DESIGNED BY RR DRAWN BY RM CHECKED BY RR SHEET: PRINT DATE 9/2/2020 10:20 AM EXTERIOR WALLS NOT MARKED SHALL BE SW1 HOLDDOWNS CALLED OUT ARE LOCATED AT BASE OF SHEAR WALLS. SEE SHEET S1 FOR HDU HOLD-DOWN ANCHOR SCHEDULE AND S5 FOR SHEAR WALL SCHEDULE _________r, L_________-J 2ND FLOOR SHEARWALLS SCALE: 1/8" = 1'-0" A B C D E F G I I I I I I I I I I I I I I I I I I I I I ,,_d„ LOWER ROOF VENT CALCULATIONS ROOF AREA 293 SQ FT REQUIRED ROOF VENTILATION AREA I 300 0.98 SO FT 40-50% IN UPPER &LOWER ROOF ROOF VENT AREA / 2 0.49 SO FT BLOCKS IN EAVES BLOCKS =AREA/ 0.074 7 ROOF VENTS IN UPPER 40-50 OPTION 1: AF50 ROOF JACK= AREA/ 0.333 2 OPTION 2: (ridge vent) CORAVENT V300 =AREA/ 0.094 5.2 FEET NOTE ! ALL FLOOR FRAMING JOISTS TO BE 18" OPEN WEB TRUSSES TO FLOOR TRUSS MANUFACTURER: DESIGNED FOR MIN. L/480 AND MAX. 1/2" DEFLECTION. + NOTE ! P.L. INDICATES: POINT LOAD ABOVE SOLID BLOCKING REQUIRED IN FLOOR FRAMING HEADER NOTE ! HEADERS NOT CALLED OUT IN PLAN SHALL BE: A 0'� \�� BM-01 Q/ LEGEND i �_ Q ROOF TRUSSES I •I U 4 -- -- - I T-------- —�—a— — -- —-------_— t� - - - - �- - - - -- - P.L. --- - -- - - - -- � ---- i I- - - - --- ---------- WALLS UNDER r----°-- .° i ��� � �Q . BN4-09 Qi � i WALLS/ FIXTURES OVER I .i I � �� I I I i � I I ra, i � H i � HEADERS &BEAMS i FLOOR PERIMETER ° �•i FLOOR TRUSSES I :_________, �__ __ � i i STAIR STRINGERS � �°� ; I I I I I I LOWER ROOF LINES I I I I �I I sTyo�A 4, �a1 I I I I EXTEND INSIDE FACE �. � ; SEE ROOF FRAMING PLAN SHEATHINGTHRU i � � � � � ' 2ND FLOOR FRAMING CORNER. NOTCH AT i TOP AND BOTTOM p1� i i PLATES s�� � I I I I I I SCALE: 1/4" = 1'-0" I I I � I I FLOOR TRUSS NOTE: 1. i i I I I I I THIS LAYOUT IS FOR SCHEMATIC PURPOSES ONLY. --------; � '�i I I I I I I REFER TO TRUSS FRAMING PLANS PER MANUFACTURER ' �--------- ; cn �-----, �-----, �___________� � �----------- ,�° i I I I I � I I AND PREPARED BY A LICENSED TRUSS ENGINEER. .i �, ••�---T---�--a-----r------,----------- I I I I I do.a. r--------------------------------------------------------------------------------------- -- �------------- r; I I I I I ; � I ------------� � �-----------' � I I II I I I i� I � �-------L, 2----------1 r-----, r-----, r----- I----�----J i �-----�- � --� �---L------ I r--- I I I �; I �� I I I I I i I i I I I I I �� I I I I I I �; I I I I I I i i I �i, I I I MAIN FLOOR SH EARWALLS ' � ------ -, _ ' �---------J � � � RESUB 1---------------�-------------------------------------------�------------------------------------------------�-=---=-L-----_-�--_----��----- �=�_---�--------I-------------- SCALE: 1 /8" = 1'-0" I I I I I I I Mar 09 2021 DEVELOPMENT SERVICES CITY OF EDMONDS DEPARTMENT Ross Engineering Design Inc ryan. ross@rossengineer.com 9/ ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN W Z W 0 W � � z � � W Z Q W J � _ � z LJJ � o W W m �_ W � :� r a �L a� 0 0 z PROJECT NO. 200305 DESIGNED BY RR DRAWN BY RM CHECKED BY RR SHEET: PRINT DATE 9/2/2020 10:20 AM ROOF PLAN NOTES • SEE DESIGN LOADS AND/OR STRUCTURAL NOTES FOR GROUND AND ROOF SNOW LOADS. • FOR MANUFACTUREDED TRUSS ROOFS: ROOF PLAN IS FOR SCHEMATIC PURPOSES ONLY. ACTUAL ROOF PLAN TO BE DESIGNED AND ENGINEERED BY A LICENSED TRUSS ENGINEER. RAFTER FRAMING PER PLAN. • TRUSS LAYOUT TO BE REVIEWED AND APPROVED BY THE TRUSS MANUFACTURER PRIOR TO CONSTRUCTION. • SHADED AREAS INDICATE OVER -FRAMING. • LOCATE DOWNSPOUTS PER SITE CONDITIONS AND PER GENERAL CONTRACTOR. • INSTALLATION OF ALL ROOFING AND WALL FLASHING SHALL BE TO INDUSTRY STANDARDS AND INCOMPLIANCE WITH CURRENT CODES. • PROVIDE CONTINUOUS ALUMINUM GUTTERS ON FASCIA AS SPECIFIED IN DETAILS. • SKYLIGHT SIZES, IF ANY, ARE APPROXIMATE. CONTRACTOR TO VERIFY ACTUAL ROUGH OPENING SIZE PER MANUFACTURER SPECIFICATIONS. • PROVIDE SOLID BLOCKING OVER ALL SUPPORTS. • PROVIDE MIN. 22"x30" ATTIC ACCESS WITH APPROVED WEATHERSTRIPPING. IF ACCESS IS IN A GARAGE, A SELF CLOSING MECHANISM MUST BE INCORPORATED. • 16d @ 8"o.c. END TRUSS TO TOP PLATES. (TYPICAL AT ALL GABLE ENDS) • ATTICS WHERE THE MAX. CLEAR HEIGHT BETWEEN JOIST AND RAFTERS IS MORE THAN 42", OR WHERE THERE ARE TWO OR MORE ADJACENT TRUSSES WITH THE SAME WEB CONFIGURATION CAPABLE OF CONTAINING A RECTANGLE 42" HIGH BY 24" WIDE OR GREATER, MUST BE CONSIDERED ATTIC WITH LIMITED STORAGE. • ATTIC SPACE SERVED BY A FIXED STAIR SHALL BE DESIGNED TO SUPPORT THE MIN. LIVE LOAD FOR SLEEPING ROOMS. ATTIC VENTILATION CALCULATIONS -- ATTIC VENTILATION (R806.1 & 806.2) PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 150 SQ. FT. OF ATTIC AREA. EXCEPTION: PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 300 SQ. FT. OF ATTIC SPACE WHEN NOT LESS THAN 40%AND NOT MORE THAN 50% OF THE REQUIRED VENTILATION AREA IS PROVIDED BY VENTILATORS LOCATED WITHIN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACED MEASURED VERTICALLY WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION OF MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. UPPER ROOF VENT CALCULATIONS ROOF AREA 2039 SQ FT REQUIRED ROOF VENTILATION AREA/ 300 6.80 SQ FT 40-50% IN UPPER &LOWER ROOF ROOF VENT AR EA/ 2 3.40 SQ FT VENT BLOCKS IN EAVES BLOCKS =AREA/ 0.074 46 ROOF VENTS IN UPPER 40-50 OPTION 1: AF50 ROOF JACK= AREA/ 0.333 11 OPTION 2: (ridge vent) CORAVENT V300 =AREA/ 0.094 36.2 FEET A B C D E F G HEADER NOTE ! HEADERS NOT CALLED OUT IN PLAN SHALL BE: A �'� \�� BM-01 Q� LEGEN D TRUSSES RAFTERS OVER FRAMING _�11111_ GARAGE WALLS UNDER ________ WALLS UNDER HEADERS &BEAMS ROOF LINES LOWER ROOF LINES ROOF PLAN SCALE: 1 /4" = 1'-0" FOR SCHEMATIC PURPOSES ONLY. REFER TO TRUSS FRAMING PLANS PER MANUFACTURER AND PREPARED BY A LICENSED TRUSS ENGINEER. RESUB Mar 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Ross Engineering Design Inc ryan. ross@rosseng i neer.com ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN W W /� W � � W ZLJJ Q W uT, i Z LJJ � o 0 W m �_ W 0 :� c O a �L w m C Z PROJECT NO. 200305 DESIGNED BY RR DRAWN BY RM CHECKED BY RR SHEET: PRINT DATE 9/2/2020 10:21 AM TYPICAL SHEAR WALL SCHEDULE NUMBER OF SHEAR WALL STUD/BLKG. SILL PLATE /SOLE PLATE FRAMING ANCHOR TO NAIL/SCREW SHEATHED EDGE 1 AT ADJOINING 67 SYMBOL SHEATHING SIDES NAILING PANEL EDGES s SIZE CONCRETE s TO RIM JOIST SHEAR CLIPS SWl 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 3"x.131" NAIL 3"x.131" TOENAIL @48"OC @6"OC @6"OC SW2 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 24" OC SEE @ 48" OC @ 6' OC SW3 STRUCT 1 8d @ 4" OC 2x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 18" OC NOTES @ 32" OC @ 4' OC SW4 1 8d @ 3" OCz 3x OR DBL. 2x4 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 14" OC @ 24" OC @ 3' OC SW5 1 8d @ 2" OCZ 3x OR DBL. 2x4 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 10" OC @ 18" OC @ 2.5" OC SW6 2 8d @ 3" OCZ 3x OR DBL. 2x4 3x 5/8" DIA. AB SDS25600 LTP4 @ 14" OC @ 18" OC @ 5" o.c. EA. FACE SHEAR WALL SCHEDULE NOTES 1. NAILS SHALL BE COMMON OR GALVANIZED BOX UNLESS NOTED OTHERWISE. 2. WHERE NAIL SPACING IS LESS THAN 4"oc, STAGGER NAILS %2". 3. ALIGN ALL VERTICAL ADJOINING PANEL EDGES WITH STUD PER SCHEDULE. PROVIDE BLOCKING PER SCHEDULE AT ALL HORIZONTAL ADJOINING PANEL EDGES. 4. 3x FRAMING MAY BE SUBSTITUTED WITH (2)2x NAILED TOGETHER W/ 16d NAILS MATCHING EDGE NAIL SPACING. STAGGER PER NOTE #2 5. AT SW1 PROVIDE STANDARD CUT WASHERS AT ALL SILL BOLTS. AT SW2 AND HIGHER PROVIDE 3"x3"x.223" STEEL PLATE WASHERS. LOCATE EDGE OF WASHER WITHIN %" OF EDGE OF SHEATHED SIDE OF SILL PLATE. HOLE IN WASHER MAY BE DIAGONALLY SLOTTED 1.75" MAX. 6. ENSURE ONE CLIP EACH END OF SHEAR WALL AT EACH REQUIRED FACE OF SHEATHING. 7. SHEAR CLIPS ARE REQUIRED ONLY AS INDICATED IN THE SECTIONS. 8. SEE DETAIL (TOP FAR RIGHT) FOR TYPICAL TOENAIL 9. SEE DETAIL (BOTTOM FAR RIGHT) FOR BLOCKING AND SHEAR CLIP REQUIREMENTS AT DOUBLE SIDED SHEAR WALL CRIPPLE STUDS AT 16" O.C. WHERE APPLICABLE TOP PLATES NAIL STUD TO HEADER W/ (8) 16d STUDS) PER PLAN FULL HEIGHT TO TOP PLATES TRIM STUDS (TRIMMERS) PER POST PLAN FLOOR BOUNDARY NAILING 1.5"x18" BOISE CASCADE VERSALAM (OR EQUIVALENT) CONT. BLOCKING SHEAR WALL SHEAR CLIPS EDGE NAILING SHEAR WALL PER PLAN (SHEATHING MAY BE OPPOSITE FACE) BEAM PER PLAN SOLID BLKG MATCH WIDTH OF BEAM/GIRDER r'�."'�'_"� TYPICAL HEADER DETAIL 6 TARING SECTION � 1 1 USSES PER SECTION 16 SOX SHEAR CLIPS PER SHEAR WALL SCHEDULE WHERE APPLICABLE TYP. SQUASH BLOCKS IN RIM JOISTS AT ALL POSTS AND HOLD-DOWNS, ALL LEVELS. SEE TYPICAL POST BLKG. DETAI L TYP. ANCHOR TYPE HOLD-DOWN W/ ANCHOR ROD PER HOLD-DOWN SCHEDULE TYP. 8d AT 12" o.c. NAILING AT ALL INTERMEDIATE SUPPORTS PANEL EDGE NAILING TYP. SILL/SOLE PLATE W/ ANCHORS PER SCHED. TYP. ANCHOR TYPE HOLD-DOWN PER PLAN WHERE APPLICABLE. SEE SCHEDULE FOR ANCHOR ROD TYP. NOTES: 1. USE THIS DETAIL AT ALL LOCATIONS WHERE BEAM WIDTH EXCEEDS 3%2" AND/OR BEAM BOTTOM BEARING IS BELOW DOUBLE TOP PLATES. 2. EXTEND BEAMS FOR 5-1/2" BEARING ON 2x6 WALLS, 3-1/2" BEARING ON 2x4 WALLS. FLO �� SHEAR WALL SW_ ID �O HOLD-DOWN ID SHEAR WALL KEY III III III III III III I - - -I r - - iT - - - - -•IT - - �. - - I.I I.I I I I•I I•I I � II I II ll II -- I� ---__ r_-- --r_ � I I I I I'I I•I I'I I II II II II II I I I I I.I I I II II I II II I I P� _ I I I'I I I I SEGMENTAL SHEAR WALL SON CS16 WITH (20) O DBL. TOP PLATE D AT EACH SIDE. Jl AS NEEDED. �,,f PER PLAN TYPICAL PLATE STRAP AT BEAMS � 7 1.5"x18" BOISE CASCADE ROOF BOUNDARY NAILING � � VERSALAM (OR EQUIVALENT) CONT. BLOCKING SHEAR WALL SHEAR � CLIPS FLOOR TRUSS PER PLAN -BOTTOM BEARING EDGE NAILING SHEARWALL PER PLAN SECTION � 12 AM PER PLAN PER PLAN �.,.� „�AM PER PLAN SECTION 17 J BLKG PER SCHED AT HORIZ. '' PANEL JOINTS w/EDGE TYPICAL TOENAIL NAILING BOTH SIDES OF JOINT TYP. BOUNDARY NAILING PER DIAPHRAGM SCHEDULE TO RIM JOISTAND BLOCKING LOCATE VERTICAL PANEL JOINT ON STUD w/ EDGE NAILING BOTH SIDES OF JOINT CONT RIM JOIST MIN (2) STUDS AT EACH HOLD-DOWN UNLESS SHEAR CLIP PER NOTED OTHERWISE PER SCHED. EACH FACE FLOOR FRAMING PLAN OR POST DOUBLE SIDED SOLID BLKG. BETWEEN SCHEDULE TYP. SHEAR WALL PER JOIST BLKG PLAN STRAP TYPE HOLD-DOWN PER PLAN TYP. _.._ _ _ _. __ _ _ _.._. _ ___ __ _. SHEAR WALL SCHEDULE AND NAILING DETAIL 13 II II II I I ROOF TRUSSES/ —�! I I I I I RAFTERS BELOW I I _ _ _ _ _ _ _ _ _ I I I I �� tN I I I I 2x6 BLOCK BETWEEN ROOF �~ _ _ _ _ _ �r TRUSSES BELOW W/ (2) 16d I I I I EA END I I � � I I I I I I i/ \ I 2x6 PLATE W/ I I � � � � I (2) 16d INTO EA ROOF I l i � I I TRUSS BELOW I�I� � \ I I I I I I I I I I�� 2x4 RAFTEfjS �a 24"o.c. POST DOV�NITO ROOF � / I I o I I \ � TRUSS BELOV� AIT 24" o.c. � � I I a I I � II � II m II � I I �� I � I I �� I I i I I � I I � I I �� I I � I I I I / I I `� I I I I � I I I I I I i� I I I I I r' I I I I i ,� I I I I I I i II II II TYPICAL ROOF OVERFRAMING � $ CONT. RIPPED 2x 16d TOENAIL AT 8" o.c. I I I I I I I I I I I I IIF I I X FLOOR FRAMING BOTH SIDES OF GLULAM BEAM WHERE APPLICABLE CONCRETE WALL PER PLAN i AT 24" o.c. JR LAN SECTION � 1S SECTION 18 DIAPHRAGM NAILING SCHEDULE NAIL SPACING NAIL SPACING AT AT BOUNDARIES INTERMEDIATE NAIL SPACING BLKG SIZE OF AND "OTHER" FRAMING AT BLOCKED LOCATION SHEATHING REQD NAIL PANEL EDGES MEMBERS PANEL JOINTS ROOF SEE STRUCT NOTES NO lOd 6" OC 12" OC 6" OC SUB-FLR NO lOd &GLUE 6" OC 12" OC 6" OC DIAPHRAGM NOTES 1. ALL DIAPHRAGM SHEATHING IS TO BE STAGGERED IN THE DIRECTION OF THE PLYWOOD SPAN PER DIAPHRAGM DETAIL 2. PROVIDE BOUNDARY NAILING CONTINUOUS AROUND THE ENTIRE PERIMETER OF THE DIAPHRAGM 3. NAILS SHALL BE COMMON OR GALVANIZED BOX 4. ALL FRAMING MEMBERS SHALL BE 2x MINIMUM NOMINAL WIDTH BLOCKED DIAPHRAGM TYPICAL CONTINUOUS WHERE INDICATED PANEL JOINT -.I� �i, � � it ��: rl li � � I, IJ tl IJ � I: rl BOUNDARY �I 11 n � �r w n IJ �f � NAILING 11 li :C li 11 11 TOP PLATE II �I: IJ Il II .l' II IJ BLOCKED CONTINUOUS �I dl� IJ PANEL JOINT Ij Ij Ij "OTHER" PANEL li li ��, U N U ]I: li EDGE NAILING INTERMEDIATE JOIST/TRUSS NAILING DIAPHRAGM DETAIL TYPICAL DIAPHRAGM NAILING 4 SHEARWALL PER PLAN PRESSURE TREATED SILL PLATE EDGE NAILING PER PER SHEARWALL SCHED SHEARWALL SCHED ANCHOR EMBED = 7" MIN. TO SILL PLATE SLAB -ON -GRADE #4 x48" AT 24" o.c. AT PER PLAN MID -DEPTH OF SLAB 4 � THICKENED SLAB r" u FOOTING PER PLAN THICKENED SLAB FOOTING AT SHEAR WALL � 9 SOLE PLATE NAIL oc in ri oc w CONCRETE PER (4) #5 DO WITH HO( BO- BEAM PER PLAN FLOOR BOUNDARY NAILING PER DIAPHRAGM SCHED aN )OR TRUSS PER PLAN JP BEARING SECTION � 14 HJt 'IER AR 5" .,.,, ,,.� , �R PLAN TOP Pl /off �u..n � �� a ni n n r r n ri i rir.r NOTES: SEE STRUCTURAL NOTES FOR TYPICAL TOP PLATE NAILING NOT SHOWN TYPICAL TOP PLATE SPLICE I rj STRAP TO HEADER BOTH SIDES OF SHEAR WALL AT'SIM' I NAIL STUD TO HDR. PER I TYP. HEADER DETAIL I I 24" MIN TYP I I 2x I HEADER PER PLAN BLOCKING I AT STRAP I o I CS16 x48" STRAP p I w I z I QLL I o � J I ��3 Q a w I x x ac a I ��z o Q � POST PER PLAN LL � aN-I () O I w � � I � _ I 6" MIN °� �o������oQc 4 HOLD-DOWN PER PLAN ANCHOR BOLTS AND SILL PATE PER SHEAR WALL SCHEDULE AND 1/S1 (3 BOLTS MINIMUM) 1 1/2" #3 HORIZ TIES @ TYP 8" o.c. & (2) AT TOP 0 SECTION — #4 VERT. EA. END OF STEM WALL AND @ 12"o.c. HOOK INTO FOOTING -FOOTING PER PLAN SHEAR WALL AT GARAGE DOOR � 1j RESUB Mar 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 'x12" NCRETE PIER POST PER PLAN SECTION 20 Ross Engineering Desig n Inc ryan. ross@rossengineer.com ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN W W �n W Z o � W Z Q W � i z LJJ � o W m �_ W � m ,_ 0 �L �.: N d 0 O Z FILE/ NO. 20058 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: PRINT DATE 9 / 1 / 2020 ROOF BOUNDARY ROOF SHEATHING PER NAILING STRUCTURAL NOTES ROOF RAFTERS PER PLAN ROOF BOUNDARY NAILING � ROOF BOUNDARY NAILING ROOF SHEATHING PER _ _° STRUCTURAL NOTES ROOF BOUNDARY NAILING ROOF BOUNDARY NAILING EDGE NAILING CONT. 2x BLKG WITH VENTING PER TYP ROOF ARCHITECTURAL. SEE 2/S5 FOR SHEATH TRUSS PER � TRUSS CONT.2x SHAPED BLKG ALTERNATE AT RAISED TRUSS 2x BLOCKING PANELS PROVIDED SHEAR WALL SW1 HEELS. BY TRUSS MANUFACTURER EDGE NAILING SHEAR WALL SHEAR CLIPS ROOF TRUSSES PER PLAN SHEAR WALL SHEAR ROOF RAFTERS PER CLIPS TRUSS AND GABLE WALL PLAN BRACING PER TRUSS SHEAR WALL H1 CLIP EACH TRUSS MANUFACTURER SHEAR CLIPS H1 EACH RAFTER EDGE NAILING SHEAR WALL SHEAR CLIPS 2x BLOCKING AT 48" o.c. EDGE NAILING 2x6 STUDS AT 16" o.c. ROOF TRUSSES PER PLAN EDGE NAILING EDGE NAILING SHEAR WALL PER PLAN TYP 2x6 STUDS AT 16" o.c. SHEAR WALL PER PLAN TYP EDGE NAILING H1 CLIP EACH TRUSS TYP SHEAR WALL PER PLAN �/ SHEAR WALL PER PLAN ROOF TRUSS PERPENDICULAR TO SHEAR WALL 1 OPTIONAL RAISED TRUSS HEEL 2 ROOF TRUSS PARALLEL TO SHEAR WALL 3 RAFTER PERPENDICULAR TO SHEAR WALL 4 RAFTER PARALLEL TO SHEAR WALL cj ROOF SHEATHING PER 10d AT 6" o.c. ROOF BOUNDARY NAILING STRUCTURAL NOTES 10d AT 6" o.c. 2x CONT. BLOCKING ROOF BOUNDARY NAILING TRUSS BLOCKING DESIGN FOR 300 PLF SHEAR LRFD 2x CONT. BLOCKING 2x BLOCKING PANELS PROVIDED BY TRUSS MANUFACTURER 10d AT 6" o.c. 16d AT 6" o.c. 16d TOENAIL AT 6" o.c. 2x CONT. BLOCKING ROOF TRUSSES PER PLAN SHEAR WALL SHEAR CLIPS 16d TOENAIL AT 6" o.c. ROOF TRUSSES PER PLAN H1 EACH TRUSS \ � 16d TOENAIL AT 6" o.c. ROOF TRUSSES PER PLAN EDGE NAILING � � MONO TRUSSES PER PLAN H1 CLIP EACH TRUSS ROOF TRUSSES PER PLAN x � � i � BEAM PER PLAN RAFTERS PER PLAN STUD WALL OR HEADER PER BEAM PER PLAN RAFTERS PER PLAN PLAN FULL HEIGHT SHEAR WALL PER PLAN SECTION 6 TRUSS TO BEAM 7 SECTION $ SECTION 9 ROOF SLOPES MAY BEAM PER PLAN VARY PER ARCHITECTURAL PONY WALL 2x STUDS ROOF BOUNDARY i AT 16" o.c. � NAILING SOLE PLATE NAILING (2) 16d TYP TOP PLATES FLOOR BOUNDARY NAILING OVERFRAMING � y y ROOF PER PLAN � I RAFTERS (2) ROWS 16d @ 3" o.c. � I PER PLAN 2x RIPPED BLOCKING AT 24" o.c. TYP I SHIM EACH FACE I I I SHEATH PONY WALL EDGE NAILING AS NEEDED I I I PER SHEAR WALL SW1 I I I I CONT. RIPPED 2x I I 16d TOENAIL AT 8" o.c. SHAPED SOLE PLATE WITH SOLE PLATE NAILING PER SHEAR WALL SCHEDULE � d ROOF BOUNDARY NAILING TYPICAL FLOOR ROOF TRUSSES SHEAR WALL SHEAR TRUSS PER PLAN CLIPS POST PER PLAN FULL HEIGHT STUD EACH SIDE OF POST. H1 CLIP EACH TRUSS ATTACH WITH 16d GLULAM BEAM PER PLAN AT 12" o.c. SHEAR WALL PER PLAN 11 12 RIDGE BEAM TO POST 13 SECTION 14 SECTION 15 RESUB Mar 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 16 17 18 19 20 Ross Engineering Desig n Inc ryan. ross@rossengineer.com ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN W W /� W Z o � W Z Q W � i z LJJ � o W m �_ W � m 0 �L �.: N d 0 O Z FILE/ NO. 20058 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: PRINT DATE 9 / 1 / 2020