BLD2023-1556_Manufacturer_Specifications_and_Installation_Instructions_12.6.2023_9.07.28_AM_3936731
FbAIKIN DZSSE ■ Standard Features • High -efficiency Copeland® scroll compressor • Advanced Copeland® CoreSense'" technology • Copper tube/enhanced aluminum fin coil - 5mm diameter on 1.5-3.5T • High density foam compressor sound blanket • Time -delay technology to ensure quiet reliable defrost • Factory -installed bi-flow liquid line filter drier • Factory -installed suction line accumulator • Factory -installed compressor crank case heater • Factory -installed high capacity muffler • High- and low-pressure switches • Service valves with sweat connections and easy access to gauge ports • Copper tube/enhanced aluminum fin coil • Fully charged for 15' of tubing length • AHRI Certified; ETL Listed Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit www.energystar.gov. SPLIT -SYSTEM HEAT PUMP UP To 15.2 SEER2 & 7.8 HSPF2 1 Y2To5ToNs ■ Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Expanded Cooling Data ......................... 4 Expanded Heating Data.......................18 Performance Data ............................... 20 AHRI Ratings (see note) ...................... 21 Dimensions .......................................... 22 Wiring Diagrams ................................. 23 Accessories .......................................... 26 ■ Cabinet Features • Removable grille -style top design compliant with LIL 60335-2-40 • Custom Nickel Gray powder -paint finish • 500-hour salt -spray tested • Wire fan discharge grille • Steel louver coil guard • Rust -resistant screws • Top and side maintenance access • Single -panel access to controls with space provided for field -installed accessories • When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane -type winds (Anchor bracket kits available.) • n Eta u5 Intertek " Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 6-Year Unit Replacement Limited Warranty and 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Additional requirements for annual maintenance are required for the Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in California or Quebec. The duration of warranty coverage in Texas and Florida differs in some cases. SS-DZSSE www.daikincomfort.com 09/23 Supersedes 08/23 NOMENCLATURE D z 5 S E A 36 1 0 A A 1 2 3 4 5 Brand D - Daikin Type - Split System X - AC R-410A Z - H P R-410A SEER 13.4-13.7=3 16.6-17.5=7 13.8-14.5=4 17.6-18.5=8 14.6-15.5=5 18.6-19.5=9 15.6-16.5=6 19.6+=0 S - Single Stage V - Variable Speed T - Two Stage Feature Q- Introductory C -Communicating (Top Flow) E - Enhanced S - Side Discharge Communicating 6 7,8 9 10 11 12 Minor Revisions A: Initial Release B: 1st Revision Major Revisions A: Initial Release B: 1st Revision Variation Electrical 1 - 208/230 V, 1 Phase, 60 Hz 3 - 208/230 V, 3 Phase, 60 Hz 4 - 460 V, 3 Phase, 60 Hz Nominal Capacity 018 - 1%: tons 042 - 3% tons 024 - 2 tons 048 - 4 tons 030 - 2%: tons 060 - 5 tons 036 - 3 tons Sales N - North A - All Kegions S - Southeast & North 2 www.daikincomfort.com SS-DZ5SE PRODUCT SPECIFICATIONS DZ5SEA DZ5SEA DZ5SEA DZ5SEAJ DZ5SEA NOMINAL CAPACITIES Cooling (BTU/h) 18,000 24,000 30,000 36,000 42,000 48 0000 60,000 Heating (BTU/h) 18,000 24,000 30,000 36,000 42,000 48,000 60,000 Decibels 67 71 1 68 71 74 72 74 COMPRESSOR RLA 9.0 11.5 14.1 16.0 17.7 19.9 25.6 LRA 42.6 59.5 67.9 91.9 110.2 110.0 151.0 Stage Single Single Single Single Single Single Two Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll CONDENSER FAN MOTOR Motor Type PSC PSC PSC ECM PSC PSC PSC Horsepower 1/6 1/6 1/6 1/3 1/4 1/4 1/5 FLA 0.95 0.97 1 0.97 2.8 1.3 1.3 1.0 REFRIGERATION SYSTEM Refrigerant Line Size' Liquid Line Size ("O.D.) %8' W, %8' %6" %B' %6" W, Suction Line Size ("O.D.) %" %" %" " 8 1%8" 1%8" 1%8' Refrigerant Connection Size Liquid Valve Size ("O.D.) Suction Valve Size ("O.D.)z- 3 %" %" %8" %8" %8" %" Valve Connection Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Refrigerant Charge 4 106 118 1 119 114 167 222 276 ELETRICAL DATA Voltage(60 Hz) 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Minimum Circuit Ampacity 5 12.2 15.3 18.6 22.8 23.4 26.2 33.0 Max. Overcurrent Protection 6 20 25 30 35 40 45 50 Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size W' or %" W' or %" W' or %" W' or %" W' or %" W' or %" W' or %" UNIT WEIGHTS Equipment Weight 171 193 215 222 264 272 309 Shipping Weight 186 213 235 242 284 292 329 ENERGY STAR° CERTIFIED r, m � m Line sizes denoted for 25' line sets, tested and rated in accordance with ARI Standard 210/240. For other line set lengths or sizes, refer to the Installation Instructions and/or the Long Line Set Applications guide. ' Installer will need to supply''%" to %" adapters for suction line connections. 3 Installer will need to supply %" to 1%" adapters for suction line connections. ° Unit is factory charged with refrigerant for 15' of %" liquid line. System charge must be adjusted per the Final Charge Adjustment procedure found in the Installation Instructions. Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes. s Must use time -delay fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. ENERGY STAR NOTES Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. The www.energystar.gov website provides up-to-date system combina- tions certified to meet ENERGY STAR requirements. SS-DZ5SE www.daikincomfort.com :z of 0 3 0 0 n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052E 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 17.9 18.2 18.7 - 17.8 18.0 18.6 - 17.3 17.6 18.1 - 16.5 16.7 17.3 - 15.5 15.8 16.3 - 14.6 14.9 15.4 - S/T 0.62 0.54 0.41 0.63 0.55 0.41 0.65 0.57 0.44 1.00 0.59 0.46 1.00 0.62 0.48 1.00 0.67 0.53 AT 19 17 14 19 17 14 19 17 14 19 17 14 18 17 13 19 18 14 550 kW 0.99 0.99 0.98 1.10 1.09 1.09 1.22 1.22 1.21 1.35 1.35 1.35 1.50 1.50 1.49 1.67 1.67 1.67 Amps 3.8 3.8 3.8 4.3 4.3 4.3 4.8 4.8 4.8 5.4 5.4 5.4 6.1 6.1 6.1 6.9 6.9 6.9 HiPR 232 233 234 268 269 271 306 307 309 348 349 350 392 393 395 439 440 442 Lo PR 124 125 128 131 133 136 138 139 142 143 145 148 149 150 153 156 157 160 MBh 18.1 18.4 18.9 18.0 18.2 18.8 17.5 17.8 18.3 16.7 17.0 17.5 15.7 16.0 16.5 14.8 15.1 15.6 S/T 0.67 0.60 0.46 0.68 0.60 0.47 0.71 0.63 0.49 1.00 0.65 0.51 1.00 0.67 0.53 1.00 0.72 0.59 AT 18 16 13 18 16 13 18 16 13 18 16 13 17 16 12 18 17 13 70 620 kW 0.99 0.99 0.99 1.10 1.10 1.10 1.22 1.22 1.22 1.35 1.35 1.35 1.50 1.50 1.50 1.68 1.67 1.67 Amps 3.8 3.8 3.8 4.3 4.3 4.3 4.9 4.9 4.9 5.5 5.5 5.5 6.1 6.1 6.1 6.9 6.9 6.9 HiPR 233 234 236 270 271 273 308 309 311 349 350 352 394 395 396 441 442 444 Lo PR 125 127 130 133 134 137 139 141 144 145 146 150 150 152 155 157 159 162 MBh 18.3 18.6 19.1 18.2 18.4 19.0 17.7 18.0 18.5 16.9 17.2 17.7 15.9 16.2 16.7 15.0 15.3 15.8 S/T 0.70 0.62 0.49 0.71 0.63 0.49 0.73 0.66 0.52 1.00 0.67 0.54 1.00 0.70 0.56 1.00 0.75 0.61 AT 17 15 12 17 15 12 17 16 12 17 15 12 17 15 12 18 16 13 675 kW 0.99 0.99 0.99 1.10 1.10 1.10 1.23 1.23 1.22 1.36 1.36 1.36 1.51 1.51 1.50 1.68 1.68 1.68 Amps 3.8 3.8 3.8 4.3 4.3 4.3 4.9 4.9 4.9 5.5 5.5 5.5 6.2 6.2 6.2 7.0 7.0 6.9 HiPR 235 236 237 271 272 274 310 311 312 351 352 353 395 396 398 443 444 445 Lo PR 127 128 131 134 136 139 141 142 145 146 148 151 152 153 156 159 160 163 MBh 17.9 18.2 18.7 19.5 17.8 18.0 18.6 19.4 17.3 17.6 18.1 18.9 16.5 16.8 17.3 18.1 15.5 15.8 16.3 17.1 14.6 14.9 15.4 16.2 S/T 0.75 0.67 0.54 0.39 0.76 0.68 0.54 0.40 1.00 0.71 0.57 0.42 1.00 0.73 0.59 0.44 1.00 0.75 0.61 0.47 1.00 1.00 0.66 0.52 AT 22 21 17 14 22 21 17 14 23 21 18 14 22 21 17 14 22 20 17 14 23 21 18 15 550 kW 0.99 0.98 0.98 0.99 1.09 1.09 1.09 1.10 1.22 1.22 1.21 1.22 1.35 1.35 1.35 1.35 1.50 1.50 1.49 1.50 1.67 1.67 1.67 1.68 Amps 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.8 4.8 4.8 4.9 5.4 5.4 5.4 5.5 6.1 6.1 6.1 6.1 6.9 6.9 6.9 6.9 HiPR 232 233 234 239 268 269 271 275 307 308 309 313 348 349 350 355 392 393 395 399 440 441 442 446 Lo PR 124 125 128 134 131 133 136 141 138 139 142 148 143 145 148 153 149 150 153 159 156 157 160 165 MBh 18.2 18.4 18.9 19.8 18.0 18.2 18.8 19.6 17.5 17.8 18.3 19.1 16.7 17.0 17.5 18.3 15.7 16.0 16.5 17.3 14.8 15.1 15.6 16.4 S/T 0.80 0.73 0.S9 0.45 0.81 0.73 0.60 0.45 1.00 0.76 0.62 0.48 1.00 0.78 0.64 0.50 1.00 0.80 0.66 0.52 1.00 1.00 0.72 0.57 AT 21 20 17 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 21 17 14 75 620 kW 0.99 0.99 0.99 1.00 1.10 1.10 1.10 1.11 1.22 1.22 1.22 1.23 1.35 1.35 1.35 1.36 1.50 1.50 1.50 1.51 1.68 1.67 1.67 1.68 Amps 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.9 4.9 4.9 4.9 5.5 5.5 5.5 5.5 6.1 6.1 6.1 6.2 6.9 6.9 6.9 7.0 HiPR 234 235 236 240 270 271 273 277 308 309 311 315 350 351 352 356 394 395 397 401 441 442 444 448 Lo PR 125 127 130 135 133 134 137 143 139 141 144 149 145 146 150 155 150 152 155 160 157 159 162 167 MBh 18.3 18.6 19.1 20.0 18.2 18.4 19.0 19.8 17.7 18.0 18.5 19.3 16.9 17.2 17.7 18.5 15.9 16.2 16.7 17.5 15.0 15.3 15.8 16.6 S/T 0.83 0.75 0.62 0.47 1.00 0.76 0.62 0.48 1.00 0.79 0.65 0.50 1.00 0.81 0.67 0.52 1.00 0.83 0.69 0.55 1.00 1.00 0.74 0.60 AT 21 19 16 13 21 19 16 12 21 19 16 13 21 19 16 12 21 19 16 12 22 20 17 13 675 kW 0.99 0.99 0.99 1.00 1.10 1.10 1.10 1.11 1.23 1.22 1.22 1.23 1.36 1.36 1.35 1.36 1.51 1.50 1.50 1.51 1.68 1.68 1.68 1.68 Amps 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.9 4.9 4.9 4.9 5.5 5.5 5.5 5.5 6.2 6.2 6.1 6.2 7.0 6.9 6.9 7.0 HiPR 235 236 238 242 272 273 274 278 310 311 312 316 351 352 354 358 395 396 398 402 443 444 445 449 Lo PR 127 128 131 137 134 136 139 144 141 142 145 151 146 148 151 156 152 153 156 162 159 160 163 169 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) 0 n Z) N H 00 H O W O 00 C H O O OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 18.0 18.3 18.8 19.6 17.9 18.1 18.7 19.5 17.4 17.7 18.2 19.0 16.6 16.9 17.4 18.2 15.6 15.9 16.4 17.2 14.7 15.0 15.5 16.3 S/T 1.00 0.80 0.66 0.52 1.00 0.81 0.67 0.53 1.00 0.83 0.70 0.55 1.00 1.00 0.71 0.57 1.00 1.00 0.74 0.59 1.00 1.00 0.79 0.64 AT 26 25 21 18 26 24 21 18 26 25 21 18 26 24 21 18 26 24 21 18 27 25 22 19 550 kW 0.99 0.99 0.98 0.99 1.10 1.09 1.09 1.10 1.22 1.22 1.21 1.22 1.35 1.35 1.35 1.36 1.50 1.50 1.49 1.50 1.67 1.67 1.67 1.68 Amps 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.8 4.8 4.8 4.9 5.4 5.4 5.4 5.5 6.1 6.1 6.1 6.2 6.9 6.9 6.9 6.9 Hi PR 232 233 235 239 269 270 271 275 307 308 310 314 348 349 351 355 393 394 395 399 440 441 443 447 Lo PR 124 126 129 134 132 133 136 142 138 140 143 148 144 145 148 154 149 151 154 159 156 158 161 166 MBh 18.2 18.5 19.0 19.8 18.1 18.3 18.9 19.7 17.6 17.9 18.4 19.2 16.8 17.1 17.6 18.4 15.8 16.1 16.6 17.4 14.9 15.2 15.7 16.5 S/T 1.00 0.85 0.72 0.57 1.00 0.86 0.72 0.58 1.00 0.89 0.75 0.60 1.00 1.00 0.77 0.62 1.00 1.00 0.79 0.65 1.00 1.00 0.84 0.70 AT 25 24 20 17 25 24 20 17 26 24 21 17 25 24 20 17 25 23 20 17 26 24 21 18 80 620 kW 0.99 0.99 0.99 1.00 1.10 1.10 1.10 1.11 1.22 1.22 1.22 1.23 1.35 1.35 1.35 1.36 1.50 1.50 1.50 1.51 1.68 1.67 1.67 1.68 Amps 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.9 4.9 4.9 4.9 5.5 5.5 5.5 5.5 6.1 6.1 6.1 6.2 6.9 6.9 6.9 7.0 Hi PR 234 235 237 241 271 272 273 277 309 310 311 316 350 351 353 357 394 395 397 401 442 443 445 449 Lo PR 126 127 130 136 133 135 138 143 140 141 145 150 145 147 150 155 151 152 156 161 158 159 162 168 MBh 18.4 18.7 19.2 20.0 18.3 18.5 19.1 19.9 17.8 18.1 18.6 19.4 17.0 17.3 17.8 18.6 16.0 16.3 16.8 17.6 15.1 15.4 15.9 16.7 S/T 1.00 0.88 0.74 0.60 1.00 0.89 0.75 0.61 1.00 0.91 0.78 0.63 1.00 1.00 0.80 0.65 1.00 1.00 0.82 0.67 1.00 1.00 0.87 0.72 AT 25 23 20 16 25 23 20 16 25 23 20 17 25 23 20 16 24 23 19 16 25 24 21 17 675 kW 0.99 0.99 0.99 1.00 1.10 1.10 1.10 1.11 1.23 1.23 1.22 1.23 1.36 1.36 1.36 1.36 1.51 1.50 1.50 1.51 1.68 1.68 1.68 1.68 Amps 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.9 4.9 4.9 4.9 5.5 5.5 5.5 5.5 6.2 6.2 6.2 6.2 7.0 7.0 6.9 7.0 Hi PR 235 236 238 242 272 273 275 279 310 311 313 317 351 352 354 358 396 397 398 402 443 444 446 450 Lo PR 127 129 132 137 135 136 139 145 141 143 146 151 147 148 152 157 152 154 157 162 159 161 164 169 MBh 18.3 18.6 19.1 19.9 18.2 18.4 19.0 19.8 17.7 18.0 18.5 19.3 16.9 17.2 17.7 18.5 15.9 16.2 16.7 17.5 15.0 15.3 15.8 16.6 S/T 1.00 0.90 0.77 0.6 1.00 0.91 0.77 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 1.00 0.7 AT 30 28 25 21 30 28 25 21 30 28 25 22 30 28 25 21 29 28 24 21 30 29 25 22 550 kW 0.99 0.99 0.99 1.0 1.10 1.10 1.09 1.1 1.22 1.22 1.22 1.2 1.35 1.35 1.35 1.4 1.50 1.50 1.50 1.5 1.67 1.67 1.67 1.7 Amps 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.9 4.8 4.8 4.9 5.5 5.5 5.4 5.5 6.1 6.1 6.1 6.2 6.9 6.9 6.9 7.0 Hi PR 233 234 236 240 270 271 273 277 308 309 311 315 349 350 352 356 394 395 396 400 441 442 444 448 Lo PR 126 128 131 136 134 135 138 143 140 142 145 150 146 147 150 156 151 153 156 161 158 159 163 168 MBh 18.5 18.8 19.3 20.2 18.4 18.6 19.2 20.0 17.9 18.2 18.7 19.5 17.1 17.4 17.9 18.7 16.1 16.4 16.9 17.7 15.2 15.5 16.0 16.8 S/T 1.00 0.96 0.82 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 1.00 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 21 29 27 24 20 28 27 23 20 30 28 25 21 85 620 kW 0.99 0.99 0.99 1.0 1.10 1.10 1.10 1.1 1.22 1.22 1.22 1.2 1.36 1.36 1.35 1.4 1.50 1.50 1.50 1.5 1.68 1.68 1.68 1.7 Amps 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.9 4.9 4.9 4.9 5.5 5.5 5.5 5.5 6.2 6.2 6.1 6.2 7.0 6.9 6.9 7.0 Hi PR 235 236 238 242 272 273 274 278 310 311 313 317 351 352 354 358 396 397 398 402 443 444 446 450 Lo PR 1 128 129 132 138 135 137 140 145 142 143 146 152 147 149 152 157 153 154 157 163 160 161 164 170 MBh 18.7 19.0 19.5 20.3 18.6 18.8 19.4 20.2 18.1 18.4 18.9 19.7 17.3 17.6 18.1 18.9 16.3 16.6 17.1 17.9 15.4 15.7 16.2 17.0 S/T 1.00 0.98 0.85 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 1.00 0.8 1.00 1.00 1.00 0.8 AT 28 26 23 20 28 26 23 20 28 27 23 20 28 26 23 20 28 26 23 19 29 27 24 21 675 kW 1.00 1.00 0.99 1.0 1.11 1.11 1.10 1.1 1.23 1.23 1.23 1.2 1.36 1.36 1.36 1.4 1.51 1.51 1.51 1.5 1.68 1.68 1.68 1.7 Amps 3.8 3.8 3.8 3.9 4.3 4.3 4.3 4.4 4.9 4.9 4.9 4.9 5.5 5.5 5.5 5.5 6.2 6.2 6.2 6.2 7.0 7.0 7.0 7.0 Hi PR 237 238 239 243 273 274 276 280 311 312 314 318 352 354 355 359 397 398 400 404 444 445 447 451 Lo PR 129 131 134 139 137 138 141 146 143 145 148 153 149 150 153 159 154 156 159 164 161 163 166 171 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) n Zj N Ln H 00 N O V O v 0 3 0 0 n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052E 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 23.6 23.9 24.6 - 23.4 23.7 24.4 - 22.8 23.1 23.8 - 21.7 22.0 22.8 - 20.4 20.8 21.5 - 19.2 19.6 20.3 - S/T 0.61 0.54 0.40 0.62 0.54 0.40 0.64 0.57 0.43 0.66 0.59 0.45 1.00 0.61 0.47 1.00 0.66 0.52 AT 20 18 15 20 18 15 20 19 15 20 18 15 20 18 15 21 19 16 700 kW 1.29 1.29 1.29 1.44 1.44 1.44 1.60 1.60 1.60 1.78 1.78 1.77 1.97 1.97 1.97 2.21 2.20 2.20 Amps 5.0 5.0 5.0 5.6 5.6 5.6 6.4 6.4 6.4 7.2 7.2 7.2 8.1 8.1 8.1 9.1 9.1 9.1 HiPR 234 235 237 271 272 274 310 311 313 352 353 354 397 398 399 445 446 447 Lo PR 123 125 128 131 132 135 137 139 142 143 144 148 148 150 153 155 157 160 MBh 23.9 24.2 25.0 23.7 24.0 24.7 23.1 23.4 24.1 22.0 22.4 23.1 20.7 21.1 21.8 19.5 19.9 20.6 S/T 0.67 0.60 0.46 0.68 0.60 0.47 0.70 0.63 0.49 1.00 0.65 0.51 1.00 0.67 0.53 1.00 0.72 0.58 AT 19 17 14 19 17 14 19 17 14 19 17 14 19 17 13 20 18 15 70 800 kW 1.30 1.30 1.30 1.45 1.4S 1.44 1.61 1.61 1.61 1.79 1.78 1.78 1.98 1.98 1.98 2.21 2.21 2.21 Amps 5.0 5.0 5.0 5.7 5.7 5.7 6.4 6.4 6.4 7.2 7.2 7.2 8.1 8.1 8.1 9.2 9.2 9.2 HiPR 236 237 239 273 274 276 312 313 315 354 355 356 399 400 401 447 448 449 Lo PR 125 127 130 133 134 137 139 141 144 145 146 149 150 152 155 157 158 162 MBh 24.3 24.6 25.3 24.1 24.4 25.1 23.5 23.8 24.5 22.4 22.7 23.4 21.1 21.4 22.1 19.9 20.3 21.0 S/T 0.71 0.63 0.49 0.71 0.64 0.50 0.74 0.66 0.52 1.00 0.68 O.S4 1.00 0.70 0.57 1.00 0.76 0.62 AT 18 16 13 18 16 13 18 17 13 18 16 13 18 16 12 19 17 14 900 kW 1.31 1.31 1.30 1.45 1.45 1.45 1.62 1.61 1.61 1.79 1.79 1.79 1.99 1.99 1.98 2.22 2.22 2.22 Amps 5.0 5.0 5.0 5.7 5.7 5.7 6.5 6.4 6.4 7.3 7.3 7.2 8.2 8.2 8.1 9.2 9.2 9.2 HiPR 238 239 241 27S 276 278 314 31S 317 3S6 357 358 401 402 403 449 450 451 Lo PR 127 129 132 135 136 139 141 143 146 147 148 151 152 154 157 159 160 164 MBh 23.6 24.0 24.7 25.7 23.4 23.7 24.4 25.5 22.8 23.1 23.8 24.9 21.7 22.1 22.8 23.8 20.4 20.8 21.5 22.5 19.2 19.6 20.3 21.4 S/T 0.74 0.67 0.53 0.38 0.75 0.67 0.53 0.39 1.00 0.70 0.56 0.42 1.00 0.72 0.58 0.44 1.00 0.74 0.60 0.46 1.00 1.00 0.65 0.51 AT 24 23 19 15 24 22 19 15 25 23 19 16 24 22 19 15 24 22 19 15 25 23 20 16 700 kW 1.29 1.29 1.29 1.30 1.44 1.44 1.44 1.45 1.60 1.60 1.60 1.61 1.78 1.78 1.77 1.78 1.97 1.97 1.97 1.98 2.20 2.20 2.20 2.21 Amps 5.0 5.0 5.0 5.0 5.6 5.6 5.6 5.7 6.4 6.4 6.4 6.4 7.2 7.2 7.2 7.2 8.1 8.1 8.1 8.1 9.1 9.1 9.1 9.2 HiPR 235 236 237 241 271 273 274 278 310 311 313 317 352 353 355 359 397 398 400 404 445 446 448 452 Lo PR 123 125 128 133 131 132 135 141 137 139 142 147 143 144 148 153 148 150 153 158 155 157 160 165 MBh 23.9 24.3 25.0 26.0 23.7 24.0 24.8 25.8 23.1 23.4 24.1 25.2 22.0 22.4 23.1 24.2 20.7 21.1 21.8 22.9 19.6 19.9 20.6 21.7 S/T 0.80 0.73 0.59 0.44 0.81 0.73 0.60 0.45 1.00 0.76 0.62 0.48 1.00 0.78 0.64 0.50 1.00 0.80 0.66 0.52 1.00 1.00 0.71 0.57 AT 23 21 18 14 23 21 18 14 23 22 18 14 23 21 18 14 23 21 18 14 24 22 19 15 75 800 kW 1.30 1.30 1.30 1.31 1.45 1.45 1.44 1.45 1.61 1.61 1.61 1.62 1.78 1.78 1.78 1.79 1.98 1.98 1.98 1.99 2.21 2.21 2.21 2.22 Amps 5.0 5.0 5.0 5.0 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.2 7.2 7.2 7.3 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.2 HiPR 237 238 239 243 273 274 276 280 312 313 315 319 354 355 357 361 399 400 402 406 447 448 450 454 Lo PR 125 127 130 135 133 134 137 143 139 141 144 149 145 146 149 155 150 152 155 160 157 159 162 167 MBh 24.3 24.6 25.3 26.4 24.1 24.4 25.1 26.2 23.5 23.8 24.5 25.6 22.4 22.7 23.4 24.5 21.1 21.4 22.2 23.2 19.9 20.3 21.0 22.0 S/T 0.84 0.76 0.62 0.48 1.00 0.77 0.63 0.49 1.00 0.79 0.66 0.51 1.00 0.81 0.67 0.53 1.00 0.83 0.70 0.55 1.00 1.00 0.75 0.60 AT 22 20 17 13 22 20 17 13 23 21 17 14 22 20 17 13 22 20 17 13 23 21 18 14 900 kW 1.31 1.31 1.30 1.31 1.45 1.45 1.45 1.46 1.62 1.61 1.61 1.62 1.79 1.79 1.79 1.80 1.99 1.99 1.98 2.00 2.22 2.22 2.21 2.23 Amps 5.0 5.0 5.0 5.1 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.3 7.2 7.2 7.3 8.2 8.1 8.1 8.2 9.2 9.2 9.2 9.2 HiPR 238 239 241 245 275 276 278 282 314 315 317 321 356 357 359 363 401 402 403 408 449 450 451 456 Lo PR 127 129 132 137 135 136 139 145 141 143 146 151 147 148 151 157 152 154 157 162 159 161 164 169 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) 0 n Z) N Ul Iv H O W O 00 C H O O OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 23.7 24.1 24.8 25.9 23.5 23.9 24.6 25.6 22.9 23.2 24.0 25.0 21.9 22.2 22.9 24.0 20.6 20.9 21.6 22.7 19.4 19.7 20.4 21.5 S/T 1.00 0.79 0.66 0.51 1.00 0.80 0.66 0.52 1.00 0.82 0.69 0.54 1.00 0.84 0.71 0.56 1.00 1.00 0.73 0.58 1.00 1.00 0.78 0.64 AT 29 27 23 20 28 27 23 19 29 27 23 20 28 27 23 19 28 26 23 19 29 28 24 20 700 kW 1.29 1.29 1.29 1.30 1.44 1.44 1.44 1.45 1.60 1.60 1.60 1.61 1.78 1.78 1.77 1.79 1.97 1.97 1.97 1.98 2.20 2.20 2.20 2.21 Amps 5.0 5.0 5.0 5.0 5.6 5.6 5.6 5.7 6.4 6.4 6.4 6.4 7.2 7.2 7.2 7.2 8.1 8.1 8.1 8.1 9.1 9.1 9.1 9.2 Hi PR 235 236 238 242 272 273 275 279 311 312 313 317 352 353 355 359 397 398 400 404 445 446 448 452 Lo PR 124 125 128 134 131 133 136 141 138 139 143 148 143 145 148 153 149 150 154 159 156 157 160 166 MBh 24.0 24.4 25.1 26.2 23.8 24.2 24.9 26.0 23.2 23.6 24.3 25.3 22.2 22.5 23.2 24.3 20.9 21.2 21.9 23.0 19.7 20.0 20.7 21.8 S/T 1.00 0.85 0.72 0.57 1.00 0.86 0.72 0.58 1.00 0.88 0.75 0.60 1.00 1.00 0.77 0.62 1.00 1.00 0.79 0.65 1.00 1.00 0.84 0.70 AT 27 26 22 18 27 25 22 18 28 26 22 19 27 25 22 18 27 25 22 18 28 26 23 19 80 800 kW 1.30 1.30 1.30 1.31 1.45 1.45 1.44 1.45 1.61 1.61 1.61 1.62 1.79 1.78 1.78 1.79 1.98 1.98 1.98 1.99 2.21 2.21 2.21 2.22 Amps 5.0 5.0 5.0 5.0 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.2 7.2 7.2 7.3 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.2 Hi PR 237 238 240 244 274 275 277 281 313 314 315 319 354 355 357 361 399 400 402 406 447 448 450 454 Lo PR 126 127 130 136 133 135 138 143 140 141 144 150 145 147 150 155 151 152 155 161 158 159 162 167 MBh 24.4 24.8 25.5 26.5 24.2 24.5 25.2 26.3 23.6 23.9 24.6 25.7 22.5 22.9 23.6 24.6 21.2 21.6 22.3 23.4 20.1 20.4 21.1 22.2 S/T 1.00 0.89 0.75 0.61 1.00 0.89 0.76 0.61 1.00 0.92 0.78 0.64 1.00 1.00 0.80 0.66 1.00 1.00 0.82 0.68 1.00 1.00 0.88 0.73 AT 26 25 21 17 26 25 21 17 27 25 21 18 26 25 21 17 26 24 21 17 27 25 22 18 900 kW 1.31 1.31 1.30 1.32 1.45 1.45 1.45 1.46 1.62 1.61 1.61 1.62 1.79 1.79 1.79 1.80 1.99 1.99 1.98 2.00 2.22 2.22 2.22 2.23 Amps 5.0 5.0 5.0 5.1 5.7 5.7 5.7 5.7 6.5 6.4 6.4 6.5 7.3 7.3 7.2 7.3 8.2 8.2 8.1 8.2 9.2 9.2 9.2 9.2 Hi PR 239 240 242 246 276 277 279 283 315 316 317 321 356 357 359 363 401 402 404 408 449 450 452 456 Lo PR 128 129 132 138 135 137 140 145 142 143 146 152 147 149 152 157 153 154 157 163 160 161 164 169 MBh 24.1 24.5 25.2 26.3 23.9 24.3 25.0 26.0 23.3 23.6 24.3 25.4 22.2 22.6 23.3 24.4 21.0 21.3 22.0 23.1 19.8 20.1 20.8 21.9 S/T 1.00 0.89 0.76 0.6 1.00 0.90 0.76 0.6 1.00 1.00 0.79 0.6 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 1.00 0.7 AT 32 30 27 23 32 30 27 23 32 31 27 23 32 30 27 23 32 30 27 23 33 31 28 24 700 kW 1.30 1.30 1.29 1.3 1.44 1.44 1.44 1.4 1.60 1.60 1.60 1.6 1.78 1.78 1.78 1.8 1.98 1.98 1.97 2.0 2.21 2.21 2.20 2.2 Amps 5.0 5.0 5.0 5.0 5.7 5.7 5.6 5.7 6.4 6.4 6.4 6.4 7.2 7.2 7.2 7.2 8.1 8.1 8.1 8.1 9.2 9.2 9.1 9.2 Hi PR 236 237 239 243 273 274 276 280 312 313 314 319 353 354 356 360 398 399 401 405 446 447 449 453 Lo PR 126 127 130 136 133 135 138 143 140 141 144 150 145 147 150 155 151 152 155 161 158 159 162 167 MBh 24.4 24.8 25.5 26.6 24.2 24.6 25.3 26.4 23.6 24.0 24.7 25.7 22.6 22.9 23.6 24.7 21.3 21.6 22.3 23.4 20.1 20.4 21.1 22.2 S/T 1.00 0.96 0.82 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 1.00 0.8 AT 31 29 26 22 31 29 26 22 31 29 26 22 31 29 26 22 31 29 25 22 32 30 27 23 85 800 kW 1.30 1.30 1.30 1.3 1.45 1.45 1.45 1.5 1.61 1.61 1.61 1.6 1.79 1.79 1.78 1.8 1.98 1.98 1.98 2.0 2.22 2.21 2.21 2.2 Amps 5.0 5.0 5.0 5.1 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.2 7.2 7.2 7.3 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.2 Hi PR 238 239 241 245 275 276 278 282 314 315 316 320 355 356 358 362 400 401 403 407 448 449 451 455 Lo PR 127 129 132 137 135 137 140 145 142 143 146 151 147 149 152 157 153 154 157 162 159 161 164 169 MBh 24.8 25.2 25.9 26.9 24.6 24.9 25.6 26.7 24.0 24.3 25.0 26.1 22.9 23.3 24.0 25.0 21.6 22.0 22.7 23.8 20.5 20.8 21.5 22.6 S/T 1.00 0.99 0.85 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 1.00 0.8 1.00 1.00 1.00 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 21 30 28 25 21 30 28 24 21 31 29 26 22 900 kW 1.31 1.31 1.31 1.3 1.46 1.46 1.45 1.5 1.62 1.62 1.62 1.6 1.79 1.79 1.79 1.8 1.99 1.99 1.99 2.0 2.22 2.22 2.22 2.2 Amps 5.1 5.1 5.0 5.1 5.7 5.7 5.7 5.8 6.5 6.5 6.4 6.5 7.3 7.3 7.3 7.3 8.2 8.2 8.2 8.2 9.2 9.2 9.2 9.3 Hi PR 240 241 243 247 277 278 280 284 316 317 318 322 357 358 360 364 402 403 405 409 450 451 453 457 Lo PR 129 131 134 139 137 139 142 147 144 145 148 153 149 151 154 159 155 156 159 164 161 163 166 171 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) n Zj N Ln ti N V O v 0 3 0 0 n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052E 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 28.9 29.3 30.2 - 28.6 29.0 29.9 - 27.9 28.3 29.2 - 26.6 27.0 27.9 - 25.0 25.4 26.3 - 23.5 24.0 24.8 - S/T 0.62 0.54 0.40 0.63 0.55 0.41 0.65 0.58 0.44 0.67 0.60 0.46 1.00 0.62 0.48 1.00 0.67 0.53 AT 19 17 14 19 17 14 19 17 14 19 17 14 19 17 14 20 18 15 875 kW 1.63 1.63 1.62 1.81 1.81 1.81 2.02 2.02 2.01 2.24 2.24 2.24 2.49 2.49 2.49 2.78 2.78 2.78 Amps 6.0 6.0 6.0 6.9 6.9 6.8 7.8 7.8 7.8 8.8 8.8 8.8 10.0 10.0 9.9 11.3 11.3 11.3 HiPR 240 241 243 278 279 281 318 319 321 361 362 363 407 408 409 456 457 459 Lo PR 120 122 125 128 129 132 134 136 139 140 141 144 145 146 149 152 153 156 MBh 29.3 29.7 30.5 29.0 29.4 30.3 28.3 28.7 29.5 27.0 27.4 28.2 25.4 25.8 26.6 23.9 24.3 25.2 S/T 0.68 0.61 0.47 0.69 0.61 0.47 0.72 0.64 0.50 0.74 0.66 0.52 1.00 0.68 0.54 1.00 0.73 0.59 AT 18 16 13 18 16 13 18 16 13 18 16 13 18 16 13 19 17 14 70 1000 kW 1.64 1.64 1.63 1.82 1.82 1.82 2.03 2.03 2.02 2.25 2.25 2.25 2.50 2.50 2.50 2.79 2.79 2.79 Amps 6.1 6.1 6.0 6.9 6.9 6.9 7.8 7.8 7.8 8.9 8.9 8.8 10.0 10.0 10.0 11.3 11.3 11.3 HiPR 242 243 245 280 281 283 320 321 323 363 364 365 409 410 412 458 459 461 Lo PR 122 124 127 130 131 134 136 137 140 141 143 146 147 148 151 153 155 158 MBh 29.7 30.1 31.0 29.5 29.9 30.7 28.7 29.1 30.0 27.4 27.8 28.7 25.8 26.2 27.1 24.4 24.8 25.7 S/T 0.72 0.64 0.50 0.72 0.65 0.51 0.75 0.67 0.53 1.00 0.69 0.55 1.00 0.71 0.58 1.00 0.77 0.63 AT 17 15 12 17 15 12 17 15 12 17 15 12 17 15 12 18 16 13 1125 kW 1.65 1.64 1.64 1.83 1.83 1.83 2.04 2.03 2.03 2.26 2.26 2.25 2.51 2.51 2.50 2.80 2.80 2.80 Amps 6.1 6.1 6.1 6.9 6.9 6.9 7.9 7.9 7.9 8.9 8.9 8.9 10.0 10.0 10.0 11.4 11.4 11.4 HiPR 244 245 247 282 283 285 322 323 325 365 366 367 411 412 414 460 461 463 Lo PR 124 126 129 131 133 136 138 139 142 143 145 148 149 150 153 155 157 160 MBh 28.9 29.3 30.2 31.5 28.7 29.1 29.9 31.2 27.9 28.3 29.2 30.5 26.6 27.0 27.9 29.2 25.0 25.4 26.3 27.6 23.6 24.0 24.8 26.2 S/T 0.75 0.68 0.54 0.39 0.76 0.68 0.54 0.40 1.00 0.71 0.57 0.42 1.00 0.73 0.59 0.44 1.00 0.75 0.61 0.47 1.00 0.80 0.66 0.52 AT 23 21 18 14 23 21 18 14 23 21 18 15 23 21 18 14 23 21 18 14 24 22 19 15 875 kW 1.63 1.63 1.62 1.64 1.81 1.81 1.81 1.82 2.02 2.02 2.01 2.03 2.24 2.24 2.24 2.25 2.49 2.49 2.48 2.50 2.78 2.78 2.78 2.79 Amps 6.0 6.0 6.0 6.1 6.9 6.8 6.8 6.9 7.8 7.8 7.8 7.8 8.8 8.8 8.8 8.9 10.0 10.0 9.9 10.0 11.3 11.3 11.3 11.3 Hi PR 240 242 243 247 278 279 281 285 318 319 321 325 361 362 364 368 407 408 410 414 456 457 459 463 Lo PR 120 122 125 130 128 129 132 137 134 136 139 144 140 141 144 149 145 146 149 155 152 153 156 161 MBh 29.3 29.7 30.6 31.9 29.0 29.4 30.3 31.6 28.3 28.7 29.5 30.9 27.0 27.4 28.3 29.6 25.4 25.8 26.7 28.0 23.9 24.4 25.2 26.5 S/T 0.82 0.74 0.60 0.45 0.82 0.74 0.60 0.46 1.00 0.77 0.63 0.48 1.00 0.79 0.65 0.50 1.00 0.81 0.67 0.53 1.00 1.00 0.73 0.58 AT 22 20 17 13 22 20 17 13 22 20 17 14 22 20 17 13 21 20 16 13 23 21 18 14 75 1000 kW 1.64 1.63 1.63 1.65 1.82 1.82 1.82 1.83 2.03 2.03 2.02 2.04 2.25 2.25 2.24 2.26 2.50 2.50 2.49 2.51 2.79 2.79 2.79 2.80 Amps 6.1 6.0 6.0 6.1 6.9 6.9 6.9 6.9 7.8 7.8 7.8 7.9 8.9 8.9 8.8 8.9 10.0 10.0 10.0 10.0 11.3 11.3 11.3 11.4 Hi PR 243 244 245 249 280 281 283 287 320 321 323 327 363 364 366 370 409 410 412 416 458 459 461 465 Lo PR 122 124 127 132 130 131 134 139 136 137 141 146 141 143 146 151 147 148 151 156 153 155 158 163 MBh 29.7 30.2 31.0 32.3 29.5 29.9 30.8 32.1 28.7 29.1 30.0 31.3 27.4 27.8 28.7 30.0 25.8 26.3 27.1 28.4 24.4 24.8 25.7 27.0 S/T 0.85 0.77 0.63 0.49 0.86 0.78 0.64 0.49 1.00 0.80 0.67 0.52 1.00 0.82 0.69 0.54 1.00 0.85 0.71 0.56 1.00 1.00 0.76 0.61 AT 21 19 16 12 21 19 16 12 21 19 16 13 21 19 16 12 21 19 16 12 22 20 17 13 1125 kW 1.64 1.64 1.64 1.65 1.83 1.83 1.82 1.84 2.03 2.03 2.03 2.04 2.26 2.26 2.25 2.27 2.51 2.51 2.50 2.52 2.80 2.80 2.79 2.81 Amps 6.1 6.1 6.1 6.1 6.9 6.9 6.9 7.0 7.9 7.9 7.9 7.9 8.9 8.9 8.9 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.4 11.4 Hi PR 244 246 247 251 282 283 285 289 322 323 325 329 365 366 368 372 411 412 414 418 460 461 463 467 Lo PR 124 126 129 134 132 133 136 141 138 139 142 148 143 145 148 153 149 150 153 158 155 157 160 165 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) 0 n Z) N tW O H O W O 00 C H O O OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 29.1 29.5 30.3 31.6 28.8 29.2 30.1 31.4 28.0 28.5 29.3 30.6 26.7 27.2 28.0 29.3 25.2 25.6 26.4 27.8 23.7 24.1 25.0 26.3 S/T 0.88 0.80 0.67 0.52 1.00 0.81 0.67 0.53 1.00 0.84 0.70 0.55 1.00 0.86 0.72 0.57 1.00 1.00 0.74 0.59 1.00 1.00 0.79 0.65 AT 27 25 22 18 27 25 22 18 27 25 22 19 27 25 22 18 26 25 21 18 28 26 23 19 875 kW 1.63 1.63 1.62 1.64 1.81 1.81 1.81 1.82 2.02 2.02 2.01 2.03 2.24 2.24 2.24 2.25 2.49 2.49 2.49 2.50 2.78 2.78 2.78 2.79 Amps 6.0 6.0 6.0 6.1 6.9 6.9 6.8 6.9 7.8 7.8 7.8 7.8 8.8 8.8 8.8 8.9 10.0 10.0 9.9 10.0 11.3 11.3 11.3 11.3 Hi PR 241 242 244 248 279 280 282 286 319 320 321 325 361 362 364 368 407 408 410 414 457 458 459 464 Lo PR 121 122 126 131 128 130 133 138 135 136 139 144 140 142 145 150 145 147 150 155 152 154 157 162 MBh 29.4 29.8 30.7 32.0 29.2 29.6 30.5 31.8 28.4 28.8 29.7 31.0 27.1 27.5 28.4 29.7 25.5 26.0 26.8 28.1 24.1 24.5 25.4 26.7 S/T 1.00 0.87 0.73 0.58 1.00 0.87 0.73 0.59 1.00 0.90 0.76 0.61 1.00 0.92 0.78 0.63 1.00 1.00 0.80 0.66 1.00 1.00 0.85 0.71 AT 26 24 21 17 26 24 21 17 26 24 21 17 26 24 21 17 25 24 20 17 26 25 21 18 80 1000 kW 1.64 1.64 1.63 1.65 1.82 1.82 1.82 1.83 2.03 2.03 2.02 2.04 2.25 2.25 2.25 2.26 2.50 2.50 2.50 2.51 2.79 2.79 2.79 2.80 Amps 6.1 6.1 6.0 6.1 6.9 6.9 6.9 6.9 7.8 7.8 7.8 7.9 8.9 8.9 8.8 8.9 10.0 10.0 10.0 10.0 11.3 11.3 11.3 11.4 Hi PR 243 244 246 250 281 282 284 288 321 322 323 327 363 364 366 370 409 410 412 416 459 460 461 466 Lo PR 123 124 127 132 130 132 135 140 136 138 141 146 142 143 146 152 147 149 152 157 154 155 158 164 MBh 29.9 30.3 31.2 32.5 29.6 30.0 30.9 32.2 28.9 29.3 30.2 31.5 27.6 28.0 28.9 30.2 26.0 26.4 27.3 28.6 24.5 25.0 25.8 27.1 S/T 1.00 0.90 0.76 0.62 1.00 0.91 0.77 0.62 1.00 0.93 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.84 0.69 1.00 1.00 0.89 0.74 AT 25 23 20 16 25 23 20 16 25 23 20 17 25 23 20 16 24 23 19 16 26 24 21 17 1125 kW 1.65 1.64 1.64 1.65 1.83 1.83 1.83 1.84 2.04 2.03 2.03 2.05 2.26 2.26 2.25 2.27 2.51 2.51 2.50 2.52 2.80 2.80 2.80 2.81 Amps 6.1 6.1 6.1 6.1 6.9 6.9 6.9 7.0 7.9 7.9 7.9 7.9 8.9 8.9 8.9 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.4 11.4 Hi PR 245 246 248 252 283 284 286 290 323 324 325 329 365 366 368 372 411 412 414 418 461 462 463 468 Lo PR 125 126 129 134 132 134 137 142 138 140 143 148 144 145 148 154 149 151 154 159 156 157 160 166 MBh 29.5 30.0 30.8 32.1 29.3 29.7 30.6 31.9 28.5 28.9 29.8 31.1 27.2 27.6 28.5 29.8 25.6 26.1 26.9 28.2 24.2 24.6 25.5 26.8 S/T 1.00 0.91 0.77 0.6 1.00 0.92 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 1.00 0.8 AT 30 28 25 22 30 28 25 22 30 29 25 22 30 28 25 22 30 28 25 21 31 29 26 23 875 kW 1.63 1.63 1.63 1.6 1.82 1.81 1.81 1.8 2.02 2.02 2.02 2.0 2.24 2.24 2.24 2.3 2.49 2.49 2.49 2.5 2.79 2.78 2.78 2.8 Amps 6.0 6.0 6.0 6.1 6.9 6.9 6.9 6.9 7.8 7.8 7.8 7.9 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.0 11.3 11.3 11.3 11.4 Hi PR 242 243 245 249 280 281 283 287 320 321 322 327 362 363 365 369 409 410 411 415 458 459 460 465 Lo PR 123 124 127 132 130 132 135 140 137 138 141 146 142 143 147 152 147 149 152 157 154 155 159 164 MBh 29.9 30.3 31.2 32.5 29.7 30.1 30.9 32.3 28.9 29.3 30.2 31.5 27.6 28.0 28.9 30.2 26.0 26.4 27.3 28.6 24.6 25.0 25.9 27.2 S/T 1.00 0.97 0.83 0.7 1.00 0.98 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.91 0.8 1.00 1.00 1.00 0.8 AT 29 27 24 21 29 27 24 21 29 28 24 21 29 27 24 21 29 27 24 20 30 28 25 21 85 1000 kW 1.64 1.64 1.64 1.7 1.83 1.82 1.82 1.8 2.03 2.03 2.03 2.0 2.25 2.25 2.25 2.3 2.50 2.50 2.50 2.5 2.80 2.79 2.79 2.8 Amps 6.1 6.1 6.1 6.1 6.9 6.9 6.9 7.0 7.9 7.9 7.8 7.9 8.9 8.9 8.9 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.3 11.4 Hi PR 244 245 247 251 282 283 285 289 322 323 324 329 364 366 367 371 411 412 413 418 460 461 463 467 Lo PR 1 125 126 129 134 132 133 136 142 138 140 143 148 144 145 148 153 149 151 154 159 156 157 160 165 MBh 30.4 30.8 31.7 33.0 30.1 30.5 31.4 32.7 29.4 29.8 30.6 32.0 28.1 28.5 29.3 30.7 26.5 26.9 27.8 29.1 25.0 25.4 26.3 27.6 S/T 1.00 1.00 0.87 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.92 0.8 1.00 1.00 0.94 0.8 1.00 1.00 1.00 0.8 AT 28 26 23 20 28 26 23 20 28 27 23 20 28 26 23 20 28 26 23 20 29 27 24 21 1125 kW 1.65 1.65 1.64 1.7 1.83 1.83 1.83 1.8 2.04 2.04 2.03 2.0 2.26 2.26 2.26 2.3 2.51 2.51 2.51 2.5 2.80 2.80 2.80 2.8 Amps 6.1 6.1 6.1 6.2 7.0 6.9 6.9 7.0 7.9 7.9 7.9 7.9 8.9 8.9 8.9 9.0 10.1 10.1 10.0 10.1 11.4 11.4 11.4 11.4 Hi PR 246 247 249 253 284 285 287 291 324 325 326 331 366 367 369 373 413 414 415 419 462 463 465 469 Lo PR 127 128 131 136 134 135 138 144 140 142 145 150 146 147 150 155 151 152 156 161 158 159 162 167 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) n Zj N Ln Ga O N O V O Q v 0 3 0 0 n 0 3 Outdoor Ambient Temperature 652F 752F 852E I 952F 1052F 1152F Entering Indoor Wet Bulb Temperature D: MBh 35.8 36.3 37.3 - 35.4 35.9 37.0 - 34.5 35.0 36.1 - 32.9 33.4 34.5 - 31.0 31.5 32.5 - 29.2 29.7 30.8 - S/T 0.63 0.56 0.43 0.64 0.57 0.44 0.66 0.59 0.46 0.68 0.61 0.48 0.70 0.63 0.50 1.00 0.68 0.55 AT 19 17 14 19 17 14 19 17 14 19 17 14 19 17 13 20 18 14 1050 kW 1.93 1.93 1.92 2.17 2.17 2.16 2.44 2.43 2.43 2.72 2.72 2.72 3.05 3.04 3.04 3.42 3.42 3.42 Amps 7.4 7.4 7.4 8.5 8.5 8.5 9.7 9.7 9.7 11.0 11.0 11.0 12.5 12.5 12.5 14.3 14.2 14.2 HiPR 245 246 248 284 285 286 324 325 327 367 368 370 414 415 417 464 465 466 Lo PR 117 119 122 125 126 129 131 132 135 136 137 140 141 143 146 148 149 152 MBh 36.4 36.9 37.9 36.0 36.5 37.6 35.1 35.6 36.7 33.5 34.0 35.1 31.6 32.1 33.1 29.8 30.3 31.4 S/T 0.67 0.60 0.47 0.68 0.61 0.48 0.71 0.63 0.50 0.72 0.65 0.52 1.00 0.67 0.54 1.00 0.72 0.59 AT 18 16 13 18 16 13 18 16 13 18 16 13 17 16 12 19 17 13 70 1200 kW 1.94 1.94 1.94 2.18 2.18 2.17 2.45 2.45 2.44 2.74 2.73 2.73 3.06 3.06 3.05 3.44 3.43 3.43 Amps 7.5 7.5 7.4 8.6 8.6 8.5 9.8 9.8 9.8 11.1 11.1 11.1 12.6 12.6 12.6 14.3 14.3 14.3 HiPR 247 248 250 286 287 289 326 327 329 369 370 372 416 417 419 466 467 469 Lo PR 120 121 124 127 128 131 133 134 137 138 139 142 143 145 148 150 151 154 MBh 37.1 37.6 38.7 36.8 37.3 38.3 35.9 36.4 37.4 34.3 34.8 35.8 32.3 32.8 33.9 30.5 31.0 32.1 S/T 0.69 0.61 0.48 0.69 0.62 0.49 0.72 0.65 0.51 0.74 0.66 0.53 1.00 0.69 0.55 1.00 0.74 0.60 AT 17 15 12 17 15 12 17 15 12 17 15 12 17 15 11 18 16 12 1350 kW 1.95 1.95 1.95 2.19 2.19 2.19 2.46 2.46 2.45 2.75 2.74 2.74 3.07 3.07 3.06 3.45 3.44 3.44 Amps 7.5 7.5 7.5 8.6 8.6 8.6 9.8 9.8 9.8 11.1 11.1 11.1 12.6 12.6 12.6 14.4 14.3 14.3 HiPR 250 251 252 288 289 291 328 329 331 372 373 374 418 419 421 468 469 471 Lo PR 122 123 126 129 130 133 135 137 140 140 142 145 146 147 150 152 153 156 MBh 35.8 36.3 37.3 39.0 35.5 36.0 37.0 38.6 34.5 35.0 36.1 37.7 32.9 33.4 34.5 36.1 31.0 31.5 32.6 34.2 29.2 29.7 30.8 32.4 S/T 0.76 0.69 0.55 0.42 0.77 0.69 0.56 0.42 0.79 0.72 0.58 0.45 1.00 0.73 0.60 0.46 1.00 0.76 0.62 0.49 1.00 0.81 0.67 0.54 AT 23 21 18 14 23 21 18 14 23 21 18 14 23 21 18 14 23 21 17 14 24 22 18 15 1050 kW 1.93 1.93 1.92 1.94 2.17 2.17 2.16 2.18 2.43 2.43 2.43 2.45 2.72 2.72 2.72 2.73 3.04 3.04 3.04 3.06 3.42 3.42 3.42 3.44 Amps 7.4 7.4 7.4 7.5 8.5 8.5 8.5 8.6 9.7 9.7 9.7 9.8 11.0 11.0 11.0 11.1 12.5 12.5 12.5 12.6 14.2 14.2 14.2 14.3 Hi PR 245 246 248 252 284 285 287 291 324 325 327 331 367 368 370 374 414 415 417 421 464 465 467 471 Lo PR 118 119 122 127 125 126 129 134 131 132 135 140 136 137 140 145 141 143 146 150 148 149 152 157 MBh 36.4 36.9 37.9 39.6 36.1 36.6 37.6 39.2 35.1 35.6 36.7 38.3 33.5 34.1 35.1 36.7 31.6 32.1 33.2 34.8 29.8 30.3 31.4 33.0 S/T 0.80 0.73 0.60 0.46 0.81 0.73 0.60 0.46 0.83 0.76 0.63 0.49 1.00 0.78 0.64 0.51 1.00 0.80 0.67 0.53 1.00 0.85 0.72 0.58 AT 22 20 17 13 22 20 17 13 22 20 17 13 22 20 17 13 22 20 16 13 23 21 17 14 75 1200 kW 1.94 1.94 1.93 1.95 2.18 2.18 2.17 2.19 2.45 2.44 2.44 2.46 2.73 2.73 2.73 2.75 3.06 3.05 3.05 3.07 3.43 3.43 3.43 3.45 Amps 7.5 7.5 7.4 7.5 8.6 8.5 8.5 8.6 9.8 9.8 9.7 9.8 11.1 11.1 11.1 11.2 12.6 12.6 12.5 12.6 14.3 14.3 14.3 14.4 Hi PR 248 249 250 255 286 287 289 293 326 327 329 333 370 371 372 377 416 417 419 423 466 467 469 473 Lo PR 120 121 124 129 127 128 131 136 133 134 137 142 138 139 142 147 143 145 148 153 150 151 154 159 MBh 37.1 37.6 38.7 40.3 36.8 37.3 38.4 40.0 35.9 36.4 37.4 39.1 34.3 34.8 35.8 37.5 32.3 32.8 33.9 35.5 30.6 31.1 32.1 33.7 S/T 0.81 0.74 0.61 0.47 0.82 0.75 0.61 0.48 1.00 0.77 0.64 0.50 1.00 0.79 0.66 0.52 1.00 0.81 0.68 0.54 1.00 0.86 0.73 0.59 AT 21 19 16 12 21 19 16 12 21 19 16 12 21 19 16 12 21 19 15 12 22 20 17 13 1350 kW 1.95 1.95 1.94 1.96 2.19 2.19 2.18 2.20 2.46 2.45 2.45 2.47 2.74 2.74 2.74 2.76 3.07 3.06 3.06 3.08 3.44 3.44 3.44 3.46 Amps 7.5 7.5 7.5 7.6 8.6 8.6 8.6 8.7 9.8 9.8 9.8 9.9 11.1 11.1 11.1 11.2 12.6 12.6 12.6 12.7 14.3 14.3 14.3 14.4 Hi PR 250 251 253 257 288 289 291 295 329 330 331 336 372 373 375 379 419 420 421 426 468 470 471 475 Lo PR 122 123 126 131 129 130 133 138 135 137 140 145 140 142 145 150 146 147 150 155 152 153 156 161 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) 0 n Z) N tW H O M ti n c 4-� O O Outdoor Ambient Temperature 652F 752F 852E F 952F 1052E 1152F Entering Indoor Wet Bulb Temperature D: MBh 36.0 36.5 37.5 39.1 35.6 36.1 37.2 38.8 34.7 35.2 36.3 37.9 33.1 33.6 34.7 36.3 31.2 31.7 32.7 34.4 29.4 29.9 31.0 32.6 S/T 0.88 0.81 0.68 0.54 1.00 0.81 0.68 0.54 1.00 0.84 0.71 0.57 1.00 0.86 0.72 0.59 1.00 0.88 0.75 0.61 1.00 1.00 0.80 0.66 AT 27 25 22 18 27 25 22 18 27 25 22 18 27 25 22 18 27 25 21 18 28 26 23 19 1050 kW 1.93 1.93 1.92 1.94 2.17 2.17 2.16 2.18 2.44 2.43 2.43 2.45 2.72 2.72 2.72 2.74 3.05 3.04 3.04 3.06 3.42 3.42 3.42 3.44 Amps 7.4 7.4 7.4 7.5 8.5 8.5 8.5 8.6 9.7 9.7 9.7 9.8 11.0 11.0 11.0 11.1 12.5 12.5 12.5 12.6 14.3 14.2 14.2 14.3 Hi PR 246 247 249 253 284 285 287 291 324 326 327 331 368 369 371 375 415 416 417 422 464 46S 467 471 Lo PR 118 119 122 127 12S 127 129 134 131 133 136 141 137 138 141 146 142 143 146 151 148 150 152 1S7 MBh 36.6 37.1 38.1 39.7 36.2 36.7 37.8 39.4 35.3 35.8 36.9 38.5 33.7 34.2 35.3 36.9 31.8 32.3 33.3 35.0 30.0 30.5 31.6 33.2 S/T 0.92 0.85 0.72 0.58 1.00 0.85 0.72 0.58 1.00 0.88 0.75 0.61 1.00 0.90 0.77 0.63 1.00 0.92 0.79 0.65 1.00 1.00 0.84 0.70 AT 26 24 21 17 26 24 21 17 26 24 21 17 26 24 21 17 26 24 20 17 27 25 21 18 80 1200 kW 1.94 1.94 1.94 1.95 2.18 2.18 2.17 2.19 2.45 2.45 2.44 2.46 2.74 2.73 2.73 2.75 3.06 3.06 3.05 3.07 3.44 3.43 3.43 3.45 Amps 7.5 7.5 7.4 7.5 8.6 8.6 8.5 8.6 9.8 9.8 9.8 9.8 11.1 11.1 11.1 11.2 12.6 12.6 12.5 12.6 14.3 14.3 14.3 14.4 Hi PR 248 249 251 255 286 287 289 293 327 328 329 334 370 371 373 377 417 418 420 424 467 468 469 474 Lo PR 120 122 124 129 127 129 132 136 133 135 138 143 139 140 143 148 144 145 148 153 150 152 155 159 MBh 37.3 37.8 38.9 40.5 37.0 37.5 38.5 40.2 36.1 36.6 37.6 39.2 34.5 35.0 36.0 37.6 32.5 33.0 34.1 35.7 30.8 31.3 32.3 33.9 S/T 1.00 0.86 0.73 0.59 1.00 0.87 0.74 0.60 1.00 0.89 0.76 0.62 1.00 0.91 0.78 0.64 1.00 1.00 0.80 0.66 1.00 1.00 0.85 0.71 AT 25 23 20 16 25 23 20 16 25 23 20 16 25 23 20 16 25 23 19 16 26 24 21 17 1350 kW 1.95 1.95 1.95 1.96 2.19 2.19 2.18 2.20 2.46 2.46 2.45 2.47 2.75 2.74 2.74 2.76 3.07 3.07 3.06 3.08 3.45 3.44 3.44 3.46 Amps 7.5 7.5 7.5 7.6 8.6 8.6 8.6 8.7 9.8 9.8 9.8 9.9 11.1 11.1 11.1 11.2 12.6 12.6 12.6 12.7 14.4 14.3 14.3 14.4 Hi PR 250 251 253 257 289 290 291 296 329 330 332 336 372 373 375 379 419 420 422 426 469 470 472 476 Lo PR 122 124 127 132 130 131 134 139 136 137 140 145 141 142 145 150 146 148 150 155 153 154 157 162 MBh 36.6 37.1 38.1 39.7 36.2 36.7 37.8 39.4 35.3 35.8 36.9 38.5 33.7 34.2 35.3 36.9 31.8 32.3 33.3 35.0 30.0 30.5 31.6 33.2 S/T 1.00 0.90 0.77 0.6 1.00 0.91 0.78 0.6 1.00 0.94 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.89 0.8 AT 31 29 25 22 30 29 25 22 31 29 25 22 30 29 25 22 30 28 25 21 31 30 26 23 1050 kW 1.93 1.93 1.93 1.9 2.17 2.17 2.17 2.2 2.44 2.44 2.43 2.5 2.73 2.73 2.72 2.7 3.05 3.05 3.04 3.1 3.43 3.43 3.42 3.4 Amps 7.4 7.4 7.4 7.5 8.5 8.5 8.5 8.6 9.7 9.7 9.7 9.8 11.1 11.1 11.0 11.1 12.5 12.5 12.5 12.6 14.3 14.3 14.2 14.3 Hi PR 247 248 250 254 285 286 288 292 326 327 328 333 369 370 372 376 416 417 418 423 466 467 468 473 Lo PR 120 121 124 129 127 128 131 136 133 134 137 142 138 140 143 148 143 145 148 153 150 151 154 159 MBh 37.2 37.7 38.7 40.3 36.8 37.3 38.4 40.0 35.9 36.4 37.5 39.1 34.3 34.8 35.9 37.5 32.4 32.9 33.9 35.6 30.6 31.1 32.2 33.8 S/T 1.00 0.95 0.81 0.7 1.00 0.95 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.89 0.7 1.00 1.00 0.93 0.8 AT 29 28 24 21 29 28 24 21 30 28 24 21 29 28 24 21 29 27 24 20 30 28 25 22 85 1200 kW 1.95 1.94 1.94 2.0 2.19 2.18 2.18 2.2 2.45 2.45 2.45 2.5 2.74 2.74 2.73 2.8 3.06 3.06 3.06 3.1 3.44 3.44 3.43 3.5 Amps 7.5 7.5 7.5 7.5 8.6 8.6 8.6 8.6 9.8 9.8 9.8 9.9 11.1 11.1 11.1 11.2 12.6 12.6 12.6 12.7 14.3 14.3 14.3 14.4 Hi PR 249 250 252 256 288 289 290 295 328 329 331 335 371 372 374 378 418 419 421 425 468 469 471 475 Lo PR 122 123 126 131 129 130 133 138 135 137 139 144 140 142 145 150 145 147 150 155 152 153 156 161 MBh 37.9 38.4 39.5 41.1 37.6 38.1 39.1 40.8 36.7 37.2 38.2 39.8 35.1 35.6 36.6 38.2 33.1 33.6 34.7 36.3 31.3 31.8 32.9 34.5 S/T 1.00 0.96 0.83 0.7 1.00 0.97 0.83 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 1.00 0.8 AT 29 27 23 20 28 27 23 20 29 27 24 20 28 27 23 20 28 26 23 19 29 28 24 21 1350 kW 1.96 1.95 1.95 2.0 2.20 2.19 2.19 2.2 2.46 2.46 2.46 2.5 2.75 2.75 2.74 2.8 3.07 3.07 3.07 3.1 3.45 3.45 3.44 3.5 Amps 7.5 7.5 7.5 7.6 8.6 8.6 8.6 8.7 9.8 9.8 9.8 9.9 11.2 11.2 11.1 11.2 12.6 12.6 12.6 12.7 14.4 14.4 14.3 14.4 Hi PR 251 252 254 258 290 291 293 297 330 331 333 337 373 375 376 380 420 421 423 427 470 471 473 477 Lo PR 124 126 129 134 131 133 136 141 137 139 142 147 143 144 147 152 148 149 152 157 154 156 159 164 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) Z) N Ui 0) N v 0 0 3 0 0 n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 40.9 41.4 42.6 - 40.5 41.1 42.3 - 39.4 40.0 41.2 - 37.6 38.2 39.4 - 35.4 35.9 37.2 - 33.3 33.9 35.1 - S/T 0.63 0.56 0.42 0.64 0.56 0.43 0.66 0.59 0.45 0.68 0.61 0.47 1.00 0.63 0.49 1.00 0.68 0.54 AT 19 17 14 19 17 14 19 17 14 19 17 14 18 17 13 19 18 14 1225 kW 2.2S 2.24 2.24 2.S0 2.50 2.49 2.78 2.78 2.77 3.09 3.08 3.08 3.43 3.43 3.42 3.83 3.83 3.82 Amps 8.2 8.2 8.2 9.4 9.4 9.3 10.7 10.7 10.6 12.1 12.1 12.0 13.6 13.6 13.6 15.5 15.4 15.4 HiPR 240 241 243 278 279 281 318 319 321 361 362 363 407 408 409 456 457 458 Lo PR 120 121 124 127 129 132 134 135 138 139 140 143 144 146 149 151 152 155 MBh 41.2 41.8 43.0 40.9 41.4 42.7 39.8 40.4 41.6 38.0 38.5 39.8 35.7 36.3 37.5 33.7 34.3 35.5 S/T 0.67 0.59 0.46 0.68 0.60 0.46 0.70 0.63 0.49 0.72 0.64 0.51 1.00 0.67 0.53 1.00 0.72 0.58 AT 18 16 13 18 16 13 18 16 13 18 16 13 18 16 13 19 17 14 70 1340 kW 2.26 2.25 2.25 2.51 2.51 2.50 2.79 2.79 2.78 3.10 3.09 3.09 3.44 3.43 3.43 3.84 3.83 3.83 Amps 8.3 8.2 8.2 9.4 9.4 9.4 10.7 10.7 10.7 12.1 12.1 12.1 13.7 13.7 13.6 15.5 15.5 15.5 HiPR 242 243 245 280 281 282 319 320 322 362 363 365 408 409 411 457 458 460 Lo PR 121 123 126 128 130 133 135 136 139 140 142 145 145 147 150 152 154 157 MBh 42.2 42.7 44.0 41.8 42.4 43.6 40.7 41.3 42.5 38.9 39.5 40.7 36.7 37.3 38.5 34.6 35.2 36.4 S/T 0.71 0.63 0.50 0.72 0.64 0.50 0.74 0.67 0.53 0.76 0.69 0.55 1.00 0.71 0.57 1.00 0.76 0.62 AT 17 15 12 17 15 12 17 15 12 17 15 12 16 15 11 18 16 12 1575 kW 2.27 2.27 2.26 2.52 2.52 2.52 2.81 2.80 2.80 3.11 3.11 3.10 3.45 3.45 3.45 3.85 3.85 3.85 Amps 8.3 8.3 8.3 9.5 9.5 9.5 10.8 10.8 10.7 12.2 12.2 12.1 13.7 13.7 13.7 15.6 15.6 15.5 HiPR 245 246 247 282 283 285 322 323 325 365 366 368 411 412 414 460 461 463 Lo PR 124 125 128 131 133 136 138 139 142 143 144 148 148 150 153 155 156 159 MBh 40.9 41.5 42.7 44.5 40.5 41.1 42.3 44.2 39.4 40.0 41.2 43.1 37.6 38.2 39.4 41.3 35.4 36.0 37.2 39.0 33.3 33.9 35.1 37.0 S/T 0.76 0.69 0.55 0.40 0.77 0.69 0.55 0.41 1.00 0.72 0.58 0.44 1.00 0.74 0.60 0.46 1.00 0.76 0.62 0.48 1.00 0.81 0.67 0.53 AT 23 21 17 14 22 21 17 14 23 21 18 14 22 21 17 14 22 20 17 14 23 22 18 15 1225 kW 2.24 2.24 2.24 2.26 2.50 2.50 2.49 2.51 2.78 2.78 2.77 2.79 3.08 3.08 3.08 3.10 3.43 3.42 3.42 3.44 3.83 3.82 3.82 3.84 Amps 8.2 8.2 8.2 8.3 9.4 9.4 9.3 9.4 10.7 10.6 10.6 10.7 12.1 12.0 12.0 12.1 13.6 13.6 13.6 13.7 15.4 15.4 15.4 15.5 Hi PR 241 242 243 248 278 280 281 285 318 319 321 325 361 362 364 368 407 408 410 414 456 457 459 463 Lo PR 120 121 124 130 127 129 132 137 134 135 138 143 139 140 144 149 144 146 149 154 151 152 155 160 MBh 41.3 41.8 43.0 44.9 40.9 41.5 42.7 44.5 39.8 40.4 41.6 43.5 38.0 38.6 39.8 41.6 35.8 36.3 37.6 39.4 33.7 34.3 35.5 37.4 S/T 0.80 0.72 0.59 0.44 0.81 0.73 0.59 0.45 1.00 0.75 0.62 0.47 1.00 0.77 0.64 0.49 1.00 0.80 0.66 0.52 1.00 0.85 0.71 0.57 AT 22 20 17 13 22 20 17 13 22 20 17 14 22 20 17 13 22 20 16 13 23 21 18 14 75 1340 kW 2.25 2.25 2.25 2.27 2.51 2.50 2.50 2.52 2.79 2.79 2.78 2.80 3.09 3.09 3.09 3.11 3.43 3.43 3.43 3.45 3.84 3.83 3.83 3.85 Amps 8.2 8.2 8.2 8.3 9.4 9.4 9.4 9.5 10.7 10.7 10.7 10.8 12.1 12.1 12.1 12.2 13.7 13.6 13.6 13.7 15.5 15.5 15.5 15.5 HiPR 242 243 245 249 280 281 283 287 320 321 322 326 362 363 365 369 408 409 411 415 457 458 460 464 Lo PR 121 123 126 131 128 130 133 138 135 136 139 144 140 142 145 150 145 147 150 155 152 154 157 162 MBh 42.2 42.8 44.0 45.8 41.8 42.4 43.6 45.5 40.8 41.3 42.6 44.4 38.9 39.5 40.7 42.6 36.7 37.3 38.5 40.3 34.7 35.2 36.5 38.3 S/T 0.84 0.76 0.63 0.48 0.85 0.77 0.63 0.49 1.00 0.80 0.66 0.52 1.00 0.82 0.68 0.54 1.00 0.84 0.70 0.56 1.00 1.00 0.75 0.61 AT 21 19 16 12 21 19 15 12 21 19 16 12 21 19 15 12 20 19 15 12 21 20 16 13 1575 kW 2.27 2.27 2.26 2.28 2.52 2.52 2.51 2.53 2.80 2.80 2.80 2.82 3.11 3.11 3.10 3.12 3.45 3.45 3.44 3.46 3.85 3.85 3.84 3.86 Amps 8.3 8.3 8.3 8.4 9.5 9.5 9.4 9.5 10.8 10.8 10.7 10.8 12.2 12.2 12.1 12.2 13.7 13.7 13.7 13.8 15.6 15.5 15.5 15.6 HiPR 245 246 248 252 283 284 285 290 322 323 325 329 365 366 368 372 411 412 414 418 460 461 463 467 Lo PR 124 125 129 134 131 133 136 141 138 139 142 147 143 144 148 153 148 150 153 158 155 156 159 165 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) Q) N Ul Ln Ni H O OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 41.1 41.7 42.9 44.7 40.7 41.3 42.5 44.4 39.7 40.2 41.5 43.3 37.8 38.4 39.6 41.5 35.6 36.2 37.4 39.2 33.6 34.1 35.3 37.2 S/T 0.89 0.81 0.67 0.53 1.00 0.82 0.68 0.54 1.00 0.84 0.71 0.56 1.00 0.86 0.73 0.58 1.00 1.00 0.75 0.60 1.00 1.00 0.80 0.66 AT 26 25 21 18 26 25 21 18 27 25 22 18 26 25 21 18 26 24 21 18 27 25 22 19 1225 kW 2.25 2.24 2.24 2.26 2.50 2.50 2.49 2.51 2.78 2.78 2.77 2.79 3.09 3.08 3.08 3.10 3.43 3.43 3.42 3.44 3.83 3.83 3.82 3.84 Amps 8.2 8.2 8.2 8.3 9.4 9.4 9.3 9.4 10.7 10.7 10.6 10.7 12.1 12.1 12.0 12.1 13.6 13.6 13.6 13.7 15.5 15.4 15.4 15.5 Hi PR 241 242 244 248 279 280 282 286 319 320 321 325 361 362 364 368 407 408 410 414 456 457 459 463 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 140 141 144 149 145 146 149 154 151 153 156 161 MBh 41.5 42.0 43.3 45.1 41.1 41.7 42.9 44.7 40.0 40.6 41.8 43.7 38.2 38.8 40.0 41.9 36.0 36.5 37.8 39.6 33.9 34.5 35.7 37.6 S/T 0.93 0.85 0.71 0.57 1.00 0.86 0.72 0.58 1.00 0.88 0.74 0.60 1.00 0.90 0.76 0.62 1.00 1.00 0.79 0.64 1.00 1.00 0.84 0.69 AT 26 24 21 17 26 24 21 17 26 24 21 17 26 24 21 17 25 24 20 17 26 25 21 18 80 1340 kW 2.25 2.25 2.25 2.27 2.51 2.51 2.S0 2.52 2.79 2.79 2.78 2.80 3.10 3.09 3.09 3.11 3.44 3.43 3.43 3.45 3.84 3.83 3.83 3.85 Amps 8.3 8.2 8.2 8.3 9.4 9.4 9.4 9.5 10.7 10.7 10.7 10.8 12.1 12.1 12.1 12.2 13.7 13.7 13.6 13.7 15.5 15.5 15.5 15.6 Hi PR 242 244 245 249 280 281 283 287 320 321 323 327 363 364 365 370 409 410 411 416 458 459 461 465 Lo PR 122 123 126 131 129 130 134 139 135 137 140 145 141 142 145 150 146 147 151 156 153 154 157 162 MBh 42.4 43.0 44.2 46.0 42.0 42.6 43.8 45.7 41.0 41.5 42.8 44.6 39.1 39.7 40.9 42.8 36.9 37.5 38.7 40.6 34.9 35.4 36.7 38.5 S/T 1.00 0.89 0.75 0.61 1.00 0.90 0.76 0.62 1.00 0.92 0.79 0.64 1.00 0.94 0.81 0.66 1.00 1.00 0.83 0.68 1.00 1.00 0.88 0.74 AT 24 23 19 16 24 23 19 16 25 23 20 16 24 23 19 16 24 22 19 16 25 24 20 17 1575 kW 2.27 2.27 2.26 2.28 2.52 2.52 2.52 2.54 2.80 2.80 2.80 2.82 3.11 3.11 3.10 3.12 3.45 3.45 3.44 3.46 3.85 3.85 3.85 3.86 Amps 8.3 8.3 8.3 8.4 9.5 9.5 9.5 9.5 10.8 10.8 10.7 10.8 12.2 12.2 12.1 12.2 13.7 13.7 13.7 13.8 15.6 15.6 15.5 15.6 Hi PR 245 246 248 252 283 284 286 290 323 324 325 330 365 366 368 372 411 412 414 418 461 462 463 467 Lo PR 125 126 129 134 132 133 136 141 138 140 143 148 144 145 148 153 149 150 153 158 155 157 160 165 MBh 41.8 42.3 43.6 45.4 41.4 42.0 43.2 45.1 40.3 40.9 42.1 44.0 38.5 39.1 40.3 42.2 36.3 36.9 38.1 39.9 34.2 34.8 36.0 37.9 S/T 1.00 0.91 0.78 0.6 1.00 0.92 0.78 0.6 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.90 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 22 30 28 25 21 30 28 25 21 31 29 26 22 1225 kW 2.25 2.25 2.24 2.3 2.50 2.50 2.50 2.5 2.79 2.78 2.78 2.8 3.09 3.09 3.08 3.1 3.43 3.43 3.43 3.4 3.83 3.83 3.83 3.8 Amps 8.2 8.2 8.2 8.3 9.4 9.4 9.4 9.5 10.7 10.7 10.7 10.7 12.1 12.1 12.1 12.1 13.6 13.6 13.6 13.7 15.5 15.5 15.4 15.5 Hi PR 242 243 245 249 280 281 283 287 320 321 322 327 362 363 365 369 408 409 411 415 458 459 460 464 Lo PR 122 124 127 132 130 131 134 139 136 137 140 146 141 143 146 151 147 148 151 156 153 155 158 163 MBh 42.2 42.7 43.9 45.8 41.8 42.4 43.6 45.4 40.7 41.3 42.5 44.4 38.9 39.5 40.7 42.5 36.7 37.2 38.5 40.3 34.6 35.2 36.4 38.3 S/T 1.00 0.95 0.82 0.7 1.00 0.96 0.82 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 1.00 0.8 AT 29 27 24 21 29 27 24 21 29 28 24 21 29 27 24 21 29 27 24 20 30 28 25 22 85 1340 kW 2.26 2.26 2.25 2.3 2.51 2.51 2.51 2.5 2.79 2.79 2.79 2.8 3.10 3.10 3.09 3.1 3.44 3.44 3.43 3.5 3.84 3.84 3.83 3.9 Amps 8.3 8.3 8.2 8.3 9.4 9.4 9.4 9.5 10.7 10.7 10.7 10.8 12.1 12.1 12.1 12.2 13.7 13.7 13.7 13.7 15.5 15.5 15.5 15.6 Hi PR 244 245 246 251 281 282 284 288 321 322 324 328 364 365 366 371 410 411 413 417 459 460 462 466 Lo PR 1 124 125 128 133 131 132 135 140 137 139 142 147 143 144 147 152 148 149 152 157 154 156 159 164 MBh 43.1 43.7 44.9 46.7 42.7 43.3 44.5 46.4 41.7 42.2 43.4 45.3 39.8 40.4 41.6 43.5 37.6 38.2 39.4 41.2 35.6 36.1 37.3 39.2 S/T 1.00 0.99 0.86 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.89 0.7 1.00 1.00 0.91 0.8 1.00 1.00 0.93 0.8 1.00 1.00 1.00 0.8 AT 28 26 23 19 28 26 23 19 28 26 23 20 28 26 23 19 28 26 23 19 29 27 24 20 1575 kW 2.27 2.27 2.27 2.3 2.53 2.53 2.52 2.5 2.81 2.81 2.80 2.8 3.11 3.11 3.11 3.1 3.46 3.45 3.45 3.5 3.86 3.85 3.85 3.9 Amps 8.3 8.3 8.3 8.4 9.5 9.5 9.5 9.6 10.8 10.8 10.8 10.9 12.2 12.2 12.2 12.3 13.8 13.7 13.7 13.8 15.6 15.6 15.6 15.6 Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 369 373 413 414 415 419 462 463 464 469 Lo PR 126 128 131 136 134 135 138 143 140 141 144 150 145 147 150 155 151 152 155 160 157 159 162 167 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) O O z 'z G) Q) IN n QD N Ln N N O 0 LO v 0 3 0 0 n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 859E I 952F 1059F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 46.9 47.5 48.9 - 46.4 47.1 48.5 - 45.2 45.9 47.3 - 43.2 43.8 45.2 - 40.6 41.3 42.7 - 38.3 39.0 40.3 - S/T 0.65 0.57 0.44 0.66 0.58 0.45 0.68 0.61 0.47 0.70 0.62 0.49 1.00 0.65 0.51 1.00 0.70 0.56 AT 19 17 13 18 17 13 19 17 14 18 17 13 18 16 13 19 18 14 1450 kW 2.52 2.52 2.51 2.81 2.81 2.81 3.14 3.14 3.13 3.50 3.49 3.49 3.89 3.89 3.88 4.35 4.35 4.35 Amps 9.4 9.3 9.3 10.7 10.7 10.7 12.2 12.2 12.2 13.8 13.8 13.8 15.6 15.6 15.6 17.7 17.7 17.7 HiPR 244 245 247 282 283 285 322 323 325 365 366 368 412 413 414 461 462 464 Lo PR 120 122 125 128 129 132 134 136 139 139 141 144 145 146 149 151 153 156 MBh 47.4 48.1 49.5 47.0 47.7 49.1 45.8 46.5 47.9 43.7 44.4 45.8 41.2 41.9 43.2 38.9 39.5 40.9 S/T 0.68 0.60 0.47 0.69 0.61 0.48 0.71 0.64 0.50 0.73 0.65 0.52 1.00 0.68 0.54 1.00 0.73 0.59 AT 18 16 13 18 16 13 18 16 13 18 16 13 17 16 12 19 17 13 70 1600 kW 2.53 2.53 2.52 2.82 2.82 2.82 3.15 3.15 3.14 3.51 3.50 3.50 3.90 3.90 3.89 4.37 4.36 4.36 Amps 9.4 9.4 9.4 10.7 10.7 10.7 12.2 12.2 12.2 13.9 13.8 13.8 15.7 15.7 15.6 17.8 17.8 17.8 HiPR 245 247 248 284 285 286 324 325 326 367 368 369 413 414 416 463 464 465 Lo PR 122 124 127 129 131 134 136 137 140 141 142 145 146 148 151 153 154 157 MBh 48.4 49.0 50.4 48.0 48.6 50.0 46.8 47.4 48.8 44.7 45.3 46.7 42.1 42.8 44.2 39.8 40.5 41.8 S/T 0.70 0.62 0.49 0.70 0.63 0.49 0.73 0.65 0.52 1.00 0.67 0.54 1.00 0.69 0.56 1.00 0.74 0.61 AT 17 15 12 17 15 12 17 15 12 17 15 12 17 15 11 18 16 12 1800 kW 2.54 2.54 2.54 2.84 2.84 2.83 3.16 3.16 3.16 3.52 3.52 3.51 3.91 3.91 3.91 4.38 4.38 4.37 Amps 9.5 9.4 9.4 10.8 10.8 10.8 12.3 12.3 12.3 13.9 13.9 13.9 15.7 15.7 15.7 17.8 17.8 17.8 HiPR 248 249 250 286 287 289 326 327 329 369 370 372 415 416 418 465 466 468 Lo PR 124 126 129 132 133 136 138 139 142 143 145 148 149 150 153 155 157 160 MBh 46.9 47.5 48.9 51.0 46.5 47.1 48.5 50.6 45.3 45.9 47.3 49.4 43.2 43.8 45.2 47.3 40.6 41.3 42.7 44.8 38.3 39.0 40.4 42.5 S/T 0.78 0.70 0.57 0.43 0.78 0.71 0.57 0.43 1.00 0.73 0.60 0.46 1.00 0.75 0.62 0.48 1.00 0.77 0.64 0.50 1.00 0.82 0.69 0.55 AT 23 21 17 14 22 21 17 14 23 21 18 14 22 21 17 14 22 20 17 14 23 22 18 15 1450 kW 2.52 2.52 2.51 2.53 2.81 2.81 2.80 2.83 3.14 3.14 3.13 3.15 3.49 3.49 3.49 3.51 3.89 3.89 3.88 3.90 4.35 4.35 4.35 4.37 Amps 9.3 9.3 9.3 9.4 10.7 10.7 10.6 10.8 12.2 12.2 12.1 12.2 13.8 13.8 13.8 13.9 15.6 15.6 15.6 15.7 17.7 17.7 17.7 17.8 Hi PR 244 245 247 251 282 283 285 289 322 323 325 329 365 366 368 372 412 413 414 419 461 462 464 468 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 139 141 144 149 145 146 149 154 151 153 156 161 MBh 47.5 48.1 49.5 51.6 47.1 47.7 49.1 51.2 45.9 46.5 47.9 50.0 43.8 44.4 45.8 47.9 41.2 41.9 43.3 45.4 38.9 39.6 40.9 43.1 S/T 0.81 0.73 0.60 0.46 0.81 0.74 0.60 0.46 1.00 0.76 0.63 0.49 1.00 0.78 0.65 0.51 1.00 0.80 0.67 0.53 1.00 0.85 0.72 0.58 AT 22 20 17 13 22 20 16 13 22 20 17 13 22 20 16 13 21 20 16 13 23 21 17 14 75 1600 kW 2.53 2.53 2.52 2.54 2.82 2.82 2.82 2.84 3.15 3.15 3.14 3.17 3.50 3.50 3.50 3.52 3.90 3.90 3.89 3.91 4.36 4.36 4.36 4.38 Amps 9.4 9.4 9.4 9.5 10.7 10.7 10.7 10.8 12.2 12.2 12.2 12.3 13.8 13.8 13.8 13.9 15.7 15.6 15.6 15.7 17.8 17.8 17.7 17.9 HiPR 246 247 248 253 284 285 287 291 324 325 327 331 367 368 370 374 413 414 416 420 463 464 466 470 Lo PR 122 124 127 132 129 131 134 139 136 137 140 145 141 142 145 151 146 148 151 156 153 154 157 162 MBh 48.4 49.1 50.4 52.6 48.0 48.6 50.0 52.1 46.8 47.4 48.8 50.9 44.7 45.4 46.7 48.9 42.2 42.8 44.2 46.3 39.8 40.5 41.9 44.0 S/T 0.82 0.75 0.61 0.47 0.83 0.75 0.62 0.48 1.00 0.78 0.65 0.51 1.00 0.80 0.66 0.52 1.00 0.82 0.69 0.55 1.00 1.00 0.74 0.60 AT 21 19 16 12 21 19 16 12 21 19 16 12 21 19 16 12 21 19 15 12 22 20 16 13 1800 kW 2.54 2.54 2.54 2.56 2.84 2.83 2.83 2.85 3.16 3.16 3.16 3.18 3.52 3.51 3.51 3.53 3.91 3.91 3.90 3.93 4.38 4.37 4.37 4.39 Amps 9.4 9.4 9.4 9.5 10.8 10.8 10.8 10.9 12.3 12.3 12.3 12.4 13.9 13.9 13.9 14.0 15.7 15.7 15.7 15.8 17.8 17.8 17.8 17.9 HiPR 248 249 251 255 286 287 289 293 326 327 329 333 369 370 372 376 416 417 418 423 465 466 468 472 Lo PR 124 126 129 134 132 133 136 141 138 139 142 148 143 145 148 153 149 150 153 158 155 157 160 165 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW =Total system power Amps = Outdoor unit amps (compressor + fan) 0 n Q) N Cn 00 H O ->F Ln 00 n c I-� O O ->E OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 47.1 47.8 49.2 51.3 46.7 47.4 48.8 50.9 45.5 46.2 47.5 49.7 43.4 44.1 45.5 47.6 40.9 41.5 42.9 45.0 38.6 39.2 40.6 42.7 S/T 0.90 0.82 0.69 0.55 1.00 0.83 0.70 0.56 1.00 0.85 0.72 0.58 1.00 0.87 0.74 0.60 1.00 1.00 0.76 0.62 1.00 1.00 0.81 0.67 AT 27 25 21 18 26 25 21 18 27 25 22 18 26 25 21 18 26 24 21 18 27 26 22 19 1450 kW 2.52 2.52 2.51 2.54 2.81 2.81 2.81 2.83 3.14 3.14 3.13 3.16 3.49 3.49 3.49 3.51 3.89 3.89 3.88 3.91 4.35 4.35 4.35 4.37 Amps 9.3 9.3 9.3 9.4 10.7 10.7 10.7 10.8 12.2 12.2 12.2 12.3 13.8 13.8 13.8 13.9 15.6 15.6 15.6 15.7 17.7 17.7 17.7 17.8 Hi PR 245 246 247 2S1 283 284 28S 290 323 324 325 330 366 367 368 373 412 413 415 419 462 463 464 469 Lo PR 121 123 126 131 128 130 133 138 135 136 139 144 140 141 144 150 14S 147 150 155 152 153 156 161 MBh 47.7 48.4 49.8 51.9 47.3 48.0 49.3 51.4 46.1 46.7 48.1 50.2 44.0 44.7 46.0 48.2 41.5 42.1 43.5 45.6 39.1 39.8 41.2 43.3 S/T 1.00 0.85 0.72 0.58 1.00 0.86 0.73 0.59 1.00 0.88 0.75 0.61 1.00 0.90 0.77 0.63 1.00 1.00 0.79 0.65 1.00 1.00 0.84 0.70 AT 26 24 21 17 26 24 21 17 26 24 21 17 26 24 20 17 25 24 20 17 27 25 21 18 80 1600 kW 2.53 2.53 2.52 2.55 2.82 2.82 2.82 2.84 3.15 3.15 3.14 3.17 3.51 3.50 3.50 3.52 3.90 3.90 3.89 3.92 4.37 4.36 4.36 4.38 Amps 9.4 9.4 9.4 9.5 10.7 10.7 10.7 10.8 12.2 12.2 12.2 12.3 13.9 13.8 13.8 13.9 15.7 15.7 15.6 15.7 17.8 17.8 17.8 17.9 Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 370 374 414 415 417 421 463 464 466 470 Lo PR 123 124 127 132 130 131 134 139 136 138 141 146 142 143 146 151 147 148 151 156 153 155 158 163 MBh 48.6 49.3 50.7 52.8 48.2 48.9 50.3 52.4 47.0 47.7 49.1 51.2 44.9 45.6 47.0 49.1 42.4 43.1 44.4 46.5 40.1 40.7 42.1 44.2 S/T 1.00 0.87 0.74 0.60 1.00 0.88 0.74 0.60 1.00 0.90 0.77 0.63 1.00 1.00 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.86 0.72 AT 25 23 20 16 25 23 20 16 25 23 20 16 25 23 20 16 25 23 19 16 26 24 20 17 1800 kW 2.54 2.54 2.54 2.56 2.84 2.83 2.83 2.85 3.16 3.16 3.16 3.18 3.52 3.52 3.51 3.53 3.91 3.91 3.91 3.93 4.38 4.38 4.37 4.39 Amps 9.5 9.4 9.4 9.5 10.8 10.8 10.8 10.9 12.3 12.3 12.3 12.4 13.9 13.9 13.9 14.0 15.7 15.7 15.7 15.8 17.8 17.8 17.8 17.9 Hi PR 248 249 251 255 287 288 289 294 327 328 329 334 370 371 372 377 416 417 419 423 466 467 468 473 Lo PR 125 126 129 135 132 134 137 142 139 140 143 148 144 145 148 153 149 151 154 159 156 157 160 165 MBh 47.9 48.6 49.9 52.1 47.5 48.1 49.5 51.6 46.3 46.9 48.3 50.4 44.2 44.9 46.2 48.4 41.7 42.3 43.7 45.8 39.3 40.0 41.4 43.5 S/T 1.00 0.92 0.79 0.7 1.00 0.93 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.91 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 22 30 28 25 21 30 28 25 21 31 29 26 22 1450 kW 2.53 2.52 2.52 2.S 2.82 2.82 2.81 2.8 3.15 3.14 3.14 3.2 3.50 3.50 3.49 3.5 3.90 3.89 3.89 3.9 4.36 4.36 4.35 4.4 Amps 9.4 9.4 9.3 9.4 10.7 10.7 10.7 10.8 12.2 12.2 12.2 12.3 13.8 13.8 13.8 13.9 15.6 15.6 15.6 15.7 17.8 17.8 17.7 17.8 Hi PR 246 247 248 253 284 285 287 291 324 325 327 331 367 368 370 374 413 414 416 420 463 464 466 470 Lo PR 123 124 127 132 130 132 135 140 136 138 141 146 142 143 146 151 147 148 151 157 154 155 158 163 MBh 48.5 49.1 50.5 52.6 48.1 48.7 50.1 52.2 46.9 47.5 48.9 51.0 44.8 45.4 46.8 48.9 42.2 42.9 44.3 46.4 39.9 40.6 42.0 44.1 S/T 1.00 0.95 0.82 0.7 1.00 0.96 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.8 1.00 1.00 1.00 0.8 AT 29 27 24 21 29 27 24 21 30 28 24 21 29 27 24 21 29 27 24 20 30 28 25 21 85 1600 kW 2.54 2.53 2.53 2.6 2.83 2.83 2.82 2.8 3.16 3.15 3.15 3.2 3.51 3.51 3.50 3.5 3.91 3.90 3.90 3.9 4.37 4.37 4.36 4.4 Amps 9.4 9.4 9.4 9.5 10.8 10.8 10.7 10.8 12.3 12.3 12.2 12.3 13.9 13.9 13.8 14.0 15.7 15.7 15.7 15.8 17.8 17.8 17.8 17.9 Hi PR 247 248 250 254 285 287 288 292 325 326 328 332 369 370 371 375 415 416 418 422 464 466 467 471 Lo PR 124 126 129 134 132 133 136 141 138 139 142 147 143 145 148 153 149 150 153 158 155 157 160 165 MBh 49.4 50.1 51.5 53.6 49.0 49.7 51.0 53.2 47.8 48.5 49.8 51.9 45.7 46.4 47.8 49.9 43.2 43.8 45.2 47.3 40.9 41.5 42.9 45.0 S/T 1.00 0.97 0.84 0.7 1.00 0.98 0.84 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 0.91 0.8 1.00 1.00 1.00 0.8 AT 28 27 23 20 28 27 23 20 29 27 23 20 28 27 23 20 28 26 23 19 29 27 24 21 1800 kW 2.55 2.55 2.54 2.6 2.84 2.84 2.84 2.9 3.17 3.17 3.16 3.2 3.52 3.52 3.52 3.5 3.92 3.92 3.91 3.9 4.38 4.38 4.38 4.4 Amps 9.5 9.5 9.4 9.5 10.8 10.8 10.8 10.9 12.3 12.3 12.3 12.4 13.9 13.9 13.9 14.0 15.7 15.7 15.7 15.8 17.9 17.9 17.8 17.9 Hi PR 250 251 252 256 288 289 290 295 328 329 330 335 371 372 373 378 417 418 420 424 467 468 469 474 Lo PR 127 128 131 136 134 135 138 144 140 142 145 150 146 147 150 155 151 152 155 160 157 159 162 167 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW =Total system power Amps = Outdoor unit amps (compressor + fan) n O O z 'z G) Q) IN n QD N Ln 0 LO v 0 3 0 0 n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052E 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 57.6 58.4 60.1 - 57.0 57.9 59.6 - 55.5 56.4 58.1 - 53.0 53.8 55.5 - 49.8 50.6 52.3 - 46.9 47.7 49.5 - S/T 0.61 0.54 0.40 0.62 0.54 0.41 0.65 0.57 0.43 0.67 0.59 0.45 1.00 0.61 0.48 1.00 0.66 0.53 AT 19 18 14 19 18 14 20 18 14 19 18 14 19 17 14 20 18 15 1600 kW 3.32 3.32 3.31 3.75 3.74 3.74 4.22 4.22 4.21 4.74 4.74 4.73 5.31 5.31 5.30 5.99 5.99 5.98 Amps 13.0 13.0 13.0 15.0 14.9 14.9 17.1 17.1 17.1 19.5 19.5 19.5 22.1 22.1 22.1 25.2 25.2 25.2 Hi PR 242 243 245 280 281 283 320 321 323 363 364 366 410 411 413 459 460 462 Lo PR 119 120 124 126 128 131 133 134 137 138 139 142 143 145 148 150 151 154 MBh 58.2 59.0 60.8 57.7 58.5 60.3 56.2 57.0 58.8 53.6 54.5 56.2 50.5 51.3 53.0 47.6 48.4 50.1 S/T 0.67 0.59 0.45 0.67 0.60 0.46 0.70 0.62 0.49 0.72 0.64 0.51 1.00 0.66 0.53 1.00 0.71 0.58 AT 18 17 13 18 17 13 19 17 13 18 17 13 18 16 13 19 17 14 70 1800 kW 3.34 3.34 3.33 3.77 3.76 3.76 4.24 4.24 4.23 4.76 4.75 4.75 5.33 5.33 5.32 6.01 6.00 6.00 Amps 13.1 13.1 13.1 15.1 15.0 15.0 17.2 17.2 17.2 19.6 19.6 19.5 22.2 22.2 22.2 25.3 25.3 25.3 HiPR 244 245 247 282 283 285 322 323 325 365 366 368 412 413 414 461 462 464 Lo PR 121 122 125 128 129 132 134 136 139 139 141 144 145 146 149 151 153 156 MBh 59.0 59.8 61.6 58.5 59.3 61.0 57.0 57.8 59.5 54.4 55.2 57.0 51.3 52.1 53.8 48.4 49.2 50.9 S/T 0.70 0.62 0.49 0.70 0.63 0.49 0.73 0.65 0.52 0.75 0.67 0.54 1.00 0.69 0.56 1.00 0.75 0.61 AT 18 16 12 18 16 12 18 16 13 18 16 12 17 16 12 18 17 13 2000 kW 3.36 3.35 3.35 3.78 3.78 3.77 4.26 4.26 4.25 4.77 4.77 4.76 5.35 5.35 5.34 6.02 6.02 6.01 Amps 13.2 13.2 13.1 15.1 15.1 15.1 17.3 17.3 17.3 19.7 19.6 19.6 22.3 22.3 22.2 25.4 25.4 25.3 HiPR 246 247 248 284 285 287 324 325 327 367 368 370 413 414 416 463 464 466 Lo PR 122 124 127 130 131 134 136 137 140 141 143 146 146 148 151 153 155 158 MBh 57.6 58.4 60.1 62.7 57.1 57.9 59.6 62.2 55.6 56.4 58.1 60.7 53.0 53.8 55.5 58.1 49.8 50.7 52.4 55.0 47.0 47.8 49.5 52.1 S/T 0.74 0.67 0.53 0.39 0.75 0.67 0.54 0.40 0.78 0.70 0.56 0.42 1.00 0.72 0.58 0.44 1.00 0.74 0.60 0.46 1.00 0.79 0.66 0.51 AT 23 22 18 15 23 22 18 15 24 22 18 15 23 22 18 15 23 21 18 14 24 22 19 16 1600 kW 3.32 3.32 3.31 3.34 3.75 3.74 3.73 3.77 4.22 4.22 4.21 4.24 4.74 4.73 4.73 4.76 5.31 5.31 5.30 5.33 5.99 5.98 5.98 6.01 Amps 13.0 13.0 13.0 13.1 15.0 14.9 14.9 15.1 17.1 17.1 17.1 17.2 19.5 19.5 19.4 19.6 22.1 22.1 22.1 22.2 25.2 25.2 25.2 25.3 HiPR 242 243 245 249 281 282 283 287 321 322 323 327 364 365 366 371 410 411 413 417 460 461 462 467 Lo PR 119 121 124 129 126 128 131 136 133 134 137 142 138 139 142 148 143 145 148 153 150 151 154 159 MBh 58.3 59.1 60.8 63.4 57.8 58.6 60.3 62.9 56.3 57.1 58.8 61.4 53.7 54.5 56.2 58.8 50.5 51.3 53.0 55.7 47.6 48.4 50.2 52.8 S/T 0.80 0.72 0.58 0.44 0.80 0.73 0.59 0.45 1.00 0.75 0.62 0.47 1.00 0.77 0.63 0.49 1.00 0.79 0.66 0.51 1.00 0.84 0.71 0.57 AT 22 21 17 14 22 21 17 14 23 21 17 14 22 21 17 14 22 20 17 13 23 21 18 15 75 1800 kW 3.34 3.33 3.33 3.36 3.76 3.76 3.75 3.79 4.24 4.24 4.23 4.26 4.76 4.75 4.74 4.78 5.33 5.33 5.32 5.35 6.01 6.00 5.99 6.03 Amps 13.1 13.1 13.0 13.2 15.0 15.0 15.0 15.1 17.2 17.2 17.2 17.3 19.6 19.6 19.5 19.7 22.2 22.2 22.2 22.3 25.3 25.3 25.2 25.4 HiPR 244 245 247 251 282 283 285 289 322 323 325 329 365 366 368 372 412 413 415 419 461 462 464 468 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 140 141 144 149 145 146 149 154 151 153 156 161 MBh 59.1 59.9 61.6 64.2 58.6 59.4 61.1 63.7 57.1 57.9 59.6 62.2 54.5 55.3 57.0 59.6 51.3 52.1 53.8 56.5 48.4 49.2 51.0 53.6 S/T 0.83 0.75 0.62 0.47 0.83 0.76 0.62 0.48 1.00 0.78 0.65 0.50 1.00 0.80 0.67 0.52 1.00 0.82 0.69 0.55 1.00 0.88 0.74 0.60 AT 22 20 16 13 22 20 16 13 22 20 17 13 22 20 16 13 21 20 16 13 22 21 17 14 2000 kW 3.35 3.35 3.34 3.38 3.78 3.78 3.77 3.80 4.26 4.25 4.25 4.28 4.77 4.77 4.76 4.79 5.35 5.34 5.34 5.37 6.02 6.02 6.01 6.04 Amps 13.2 13.2 13.1 13.3 15.1 15.1 15.1 15.2 17.3 17.3 17.2 17.4 19.7 19.6 19.6 19.8 22.3 22.3 22.2 22.4 25.4 25.4 25.3 25.5 HiPR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 370 374 414 415 416 421 463 464 466 470 Lo PR 122 124 127 132 130 131 134 139 136 137 140 145 141 143 146 151 146 148 151 156 153 155 158 163 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) 0 n Z) N Ul Ql O H O O 0 C N O OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 57.9 58.7 60.4 63.0 57.4 58.2 59.9 62.5 55.9 56.7 58.4 61.0 53.3 54.1 55.8 58.4 50.1 50.9 52.7 55.3 47.3 48.1 49.8 52.4 S/T 0.87 0.79 0.66 0.51 1.00 0.80 0.66 0.52 1.00 0.82 0.69 0.55 1.00 0.84 0.71 0.57 1.00 0.87 0.73 0.59 1.00 1.00 0.78 0.64 AT 27 26 22 19 27 26 22 19 28 26 22 19 27 26 22 19 27 25 22 18 28 26 23 20 1600 kW 3.32 3.32 3.31 3.34 3.75 3.74 3.74 3.77 4.22 4.22 4.21 4.25 4.74 4.73 4.73 4.76 5.31 5.31 5.30 5.34 5.99 5.98 5.98 6.01 Amps 13.0 13.0 13.0 13.1 15.0 14.9 14.9 15.1 17.1 17.1 17.1 17.2 19.5 19.5 19.4 19.6 22.1 22.1 22.1 22.2 25.2 25.2 25.2 25.3 HIM 243 244 246 250 281 282 284 288 321 322 324 328 364 365 367 371 410 412 413 417 460 461 463 467 Lo PR 120 121 124 129 127 128 131 136 133 135 138 143 138 140 143 148 144 145 148 153 150 152 155 160 MBh 58.6 59.4 61.1 63.7 58.1 58.9 60.6 63.2 56.6 57.4 59.1 61.7 54.0 54.8 56.5 59.1 50.8 51.6 53.3 56.0 47.9 48.7 50.5 53.1 S/T 0.92 0.85 0.71 0.57 1.00 0.85 0.72 0.57 1.00 0.88 0.74 0.60 1.00 0.90 0.76 0.62 1.00 1.00 0.78 0.64 1.00 1.00 0.83 0.69 AT 26 25 21 18 26 25 21 18 27 25 21 18 26 25 21 18 26 24 21 17 27 25 22 19 80 1800 kW 3.34 3.34 3.33 3.36 3.77 3.76 3.76 3.79 4.24 4.24 4.23 4.26 4.76 4.75 4.75 4.78 5.33 5.33 5.32 5.35 6.01 6.00 6.00 6.03 Amps 13.1 13.1 13.1 13.2 15.1 15.0 15.0 15.2 17.2 17.2 17.2 17.3 19.6 19.6 19.5 19.7 22.2 22.2 22.2 22.3 25.3 25.3 25.3 25.4 Hi PR 245 246 247 252 283 284 286 290 323 324 326 330 366 367 369 373 412 413 415 419 462 463 465 469 Lo PR 121 123 126 131 128 130 133 138 135 136 139 144 140 142 145 150 145 147 150 155 152 153 156 161 MBh 59.4 60.2 61.9 64.5 58.9 59.7 61.4 64.0 57.4 58.2 59.9 62.5 54.8 55.6 57.3 59.9 51.6 52.4 54.1 56.8 48.7 49.5 51.3 53.9 S/T 1.00 0.88 0.74 0.60 1.00 0.88 0.75 0.60 1.00 0.91 0.77 0.63 1.00 0.93 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.87 0.72 AT 26 24 20 17 26 24 20 17 26 24 21 17 26 24 20 17 25 24 20 17 26 25 21 18 2000 kW 3.36 3.35 3.35 3.38 3.78 3.78 3.77 3.81 4.26 4.26 4.25 4.28 4.77 4.77 4.76 4.80 5.35 5.35 5.34 5.37 6.02 6.02 6.01 6.05 Amps 13.2 13.2 13.1 13.3 15.1 15.1 15.1 15.2 17.3 17.3 17.3 17.4 19.7 19.6 19.6 19.8 22.3 22.3 22.2 22.4 25.4 25.4 25.3 25.5 Hi PR 246 247 249 253 285 286 287 292 325 326 327 332 368 369 370 375 414 415 417 421 464 465 466 471 Lo PR 123 124 127 132 130 132 135 140 136 138 141 146 142 143 146 151 147 148 152 157 154 155 158 163 MBh 58.9 59.7 61.4 64.0 58.3 59.2 60.9 63.5 56.8 57.7 59.4 62.0 54.3 55.1 56.8 59.4 51.1 51.9 53.6 56.3 48.2 49.0 50.8 53.4 S/T 1.00 0.89 0.76 0.6 1.00 0.90 0.77 0.6 1.00 1.00 0.79 0.6 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.88 0.7 AT 31 29 26 22 31 29 26 22 31 29 26 22 31 29 26 22 31 29 25 22 32 30 27 23 1600 kW 3.33 3.33 3.32 3.4 3.76 3.75 3.74 3.8 4.23 4.23 4.22 4.3 4.75 4.74 4.74 4.8 5.32 5.32 5.31 5.3 6.00 5.99 5.99 6.0 Amps 13.0 13.0 13.0 13.1 15.0 15.0 15.0 15.1 17.2 17.2 17.1 17.3 19.5 19.5 19.5 19.6 22.2 22.2 22.1 22.3 25.3 25.2 25.2 25.4 Hi PR 244 245 247 251 282 283 285 289 322 323 325 329 365 366 368 372 412 413 414 419 461 462 464 468 Lo PR 121 123 126 131 129 130 133 138 135 136 139 144 140 142 145 150 146 147 150 155 152 154 157 162 MBh 59.5 60.3 62.1 64.7 59.0 59.8 61.6 64.2 57.5 58.3 60.1 62.7 54.9 55.8 57.5 60.1 51.8 52.6 54.3 56.9 48.9 49.7 51.4 54.1 S/T 1.00 0.95 0.81 0.7 1.00 0.95 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.94 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 22 30 28 25 21 30 28 25 21 31 29 26 22 85 1800 kW 3.35 3.35 3.34 3.4 3.77 3.77 3.76 3.8 4.25 4.25 4.24 4.3 4.77 4.76 4.75 4.8 5.34 5.34 5.33 5.4 6.02 6.01 6.01 6.0 Amps 13.1 13.1 13.1 13.2 15.1 15.1 15.0 15.2 17.3 17.3 17.2 17.4 19.6 19.6 19.6 19.7 22.3 22.2 22.2 22.4 25.3 25.3 25.3 25.4 Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 370 374 413 414 416 420 463 464 466 470 Lo PR 123 124 127 132 130 132 135 140 136 138 141 146 142 143 146 151 147 149 152 157 154 155 158 163 MBh 60.3 61.1 62.9 65.5 59.8 60.6 62.3 65.0 58.3 59.1 60.8 63.5 55.7 56.5 58.3 60.9 52.6 53.4 55.1 57.7 49.7 50.5 52.2 54.9 S/T 1.00 0.98 0.84 0.7 1.00 0.98 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 0.92 0.8 1.00 1.00 1.00 0.8 AT 29 27 24 21 29 27 24 20 29 28 24 21 29 27 24 20 29 27 24 20 30 28 25 21 2000 kW 3.37 3.36 3.35 3.4 3.79 3.79 3.78 3.8 4.27 4.26 4.26 4.3 4.78 4.78 4.77 4.8 5.36 5.35 5.35 5.4 6.03 6.03 6.02 6.1 Amps 13.2 13.2 13.2 13.3 15.2 15.1 15.1 15.3 17.3 17.3 17.3 17.4 19.7 19.7 19.7 19.8 22.3 22.3 22.3 22.4 25.4 25.4 25.4 25.5 Hi PR 248 249 250 254 286 287 288 293 326 327 328 333 369 370 372 376 415 416 418 422 465 466 467 472 Lo PR 125 126 129 134 132 133 136 141 138 140 143 148 144 145 148 153 149 150 153 158 155 157 160 165 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) 0 n QD N Ul O O I� EXPANDED HEATING DATA DZ5SEA1810A*+AMST30BU1400A* OUTDOOR .0 1 55 1 50 1 47 1 45 1 40 1 35 1 30 1 25 1 20 MBh 22.7 21.2 19.8 18.3 17.4 16.7 15.0 13.4 12.1 11.1 10.4 10.0 9.5 8.3 7.0 5.8 4.6 T/R 32.6 30.8 28.9 27.1 26.0 25.0 22.4 20.0 18.0 16.6 15.5 14.9 14.2 12.4 10.5 8.7 6.8 KW 1.4 1.4 1.3 1.3 = 1.3 1.3 1.3 1.2 1.2 1.2 1.2 1.2 1.1 1.1 1.1 1.1 AMPS 5.1 5.0 4.9 4.8 4.7 4.7 4.6 4.5 4.4 4.3 4.2 4.1 4.1 4.0 3.9 3.8 3.7 COP 4.79 4.55 4.31 4.06 3.90 3.77 3.44 3.13 2.88 2.69 2.57 2.50 2.40 2.13 1.85 1.55 1.25 Hi PR 363 351 339 327 320 315 304 292 280 268 257 249 245 233 221 209 198 LO PR 148 139 130 121 115 111 102 93 84 74 65 60 56 47 38 28 19 DZ5SEA2410A*+AMST30BU1400A* OUTDOOR .0 1 55 1 50 1 47 1 45 1 40 1 35 1 30 MBh 30.5 28.4 26.4 24.5 23.2 22.2 19.8 17.7 15.9 14.5 13.5 13.0 12.3 10.6 8.9 7.2 5.5 T/R 33.9 32.0 30.0 28.0 26.9 25.7 23.0 20.4 18.4 16.8 15.7 15.0 14.3 12.3 10.3 8.4 6.4 KW 2.0 2.0 1.9 1.9 1.8 1.8 1.8 1.7 1.7 1.6 1.6 1.5 1.5 1.5 1.4 1.3 1.3 AMPS 7.5 7.3 7.1 6.9 6.7 6.6 6.4 6.2 5.9 5.7 5.5 5.4 5.3 5.0 4.8 4.6 4.4 COP 4.41 4.22 4.03 3.84 3.70 3.59 3.30 3.02 2.80 2.65 2.55 2.50 2.40 2.15 1.87 1.57 1.25 Hi PR 377 365 353 340 333 328 316 304 291 279 267 259 254 242 230 218 205 LO PR 142 133 124 116 110 107 98 89 80 71 62 57 54 45 36 27 18 DZ5SEA3010A*+AMST30BU1400A* OUTDOOR .i 1 55 1 50 MBh 36.4 34.2 32.0 29.8 28.4 27.4 24.8 22.4 20.5 19.0 18.0 17.4 16.7 14.8 13.0 11.2 9.3 T/R 32.4 30.7 29.0 27.3 26.3 25.4 23.0 20.8 18.9 17.6 16.6 16.1 15.4 13.7 12.0 10.3 8.6 KW 2.4 2.3 2.3 2.3 2.2 2.2 2.2 2.2 2.1 2.1 2.1 2.0 2.0 2.0 2.0 1.9 1.9 AMPS 8.7 8.6 8.4 8.3 8.2 8.1 8.0 7.8 7.7 7.5 7.4 7.3 7.2 7.1 6.9 6.8 6.6 COP 4.49 4.28 4.06 3.85 3.70 3.59 3.31 3.04 2.81 2.66 2.56 2.50 2.41 2.18 1.95 1.70 1.45 Hi PR 385 373 360 348 340 335 323 310 298 285 273 265 260 248 235 222 210 LO PR 137 129 120 112 107 103 95 86 77 69 60 55 52 43 35 26 18 DZ5SEA3610A*+AMST42CU1400A* OUTDOOR .0 MBh 44.8 41.9 39.0 36.2 34.4 33.1 29.7 26.6 24.0 22.1 20.8 20.0 19.0 16.6 14.2 11.8 9.4 T/R 36.9 34.8 32.8 30.7 29.5 28.4 25.5 22.8 20.6 19.0 17.8 17.1 16.3 14.3 12.2 10.1 8.1 KW 3.1 3.1 3.0 2.9 2.9 2.9 2.8 2.7 2.6 2.6 2.5 2.4 2.4 2.3 2.3 2.2 2.1 AMPS 12.0 11.6 11.3 11.0 10.8 10.7 10.4 10.0 9.7 9.4 9.1 8.9 8.8 8.5 8.1 7.8 7.5 COP 4.17 4.00 3.81 3.63 3.50 3.40 3.13 2.88 2.68 2.54 2.45 2.40 2.31 2.08 1.84 1.58 1.30 Hi PR 397 384 371 358 351 345 332 320 307 294 281 273 268 255 242 229 216 LO PR 1 133 125 117 108 1 104 100 92 84 75 67 59 54 1 50 42 34 26 1 17 18 www.daikincomfort.com SS-DZ5SE EXPANDED HEATING DATA (CONT.) DZ5SEA4210A*+AMST42CU1400A* OUTDOOR .0 MBh 51.6 48.3 45.2 42.0 40.0 38.5 34.8 31.3 28.5 26.4 24.8 24.0 22.9 20.3 17.6 14.9 12.3 T/R 34.3 32.4 30.6 28.7 27.6 26.6 24.0 21.6 19.7 18.2 17.2 16.6 15.8 14.0 12.2 10.3 8.5 KW 3.5 3.4 3.3 3.3 3.3 3.2 3.2 3.1 3.1 3.0 3.0 2.9 2.9 2.9 2.8 2.7 2.7 AMPS 12.9 12.6 12.4 12.2 12.0 11.9 11.7 11.5 11.2 11.0 10.8 10.6 10.5 10.3 10.0 9.8 9.6 COP 4.38 4.17 3.96 3.74 3.60 3.49 3.21 2.94 2.72 2.56 2.46 2.40 2.31 2.08 1.84 1.59 1.34 Hi PR 395 382 369 356 348 343 330 318 305 292 279 271 266 253 241 228 215 LO PR 132 124 115 107 102 99 91 83 74 66 58 53 50 42 33 25 17 DZ5SEA4810A*+AMST48CU1400A* OUTDOOR .0 1 55 1 50 1 47 1 45 1 40 1 35 1 30 MBh 59.1 55.4 51.8 48.3 46.0 44.4 40.2 36.2 33.0 30.7 28.9 28.0 26.8 23.8 20.8 17.8 14.8 T/R 36.0 34.1 32.2 30.3 29.2 28.1 25.5 23.0 20.9 19.4 18.3 17.8 17.0 15.1 13.2 11.3 9.4 KW 3.9 3.8 3.7 3.7 3.7 3.6 3.6 3.5 3.4 3.4 3.3 3.3 3.3 3.2 3.1 3.1 3.0 AMPS 14.5 14.2 13.9 13.7 13.5 13.4 13.2 12.9 12.6 12.4 12.1 12.0 11.9 11.6 11.3 11.1 10.8 COP 4.48 4.27 4.06 3.85 3.70 3.59 3.31 3.03 2.81 2.66 2.55 2.50 2.41 2.18 1.94 1.69 1.44 Hi PR 433 419 405 391 382 376 362 348 334 320 306 298 292 278 264 250 236 LO PR 137 128 120 111 106 103 94 86 77 69 60 55 52 43 35 26 18 DZ5SEA6010A*+AMST60DU1400A* OUTDOOR .0 MBh 71.1 67.2 63.3 59.5 55.2 51.0 46.4 43.2 40.7 38.9 38.0 36.7 33.6 30.4 27.2 24.1 T/R 35.4 33.7 32.1 30.5 29.5 28.6 26.4 24.2 22.4 21.1 20.1 19.7 19.0 17.4 15.7 14.1 12.4 KW 4.7 4.7 4.6 4.6 = 4.5 4.4 4.4 4.3 4.2 4.2 4.1 4.1 4.0 4.0 3.9 3.8 AMPS 17.8 17.5 17.2 17.0 16.8 16.7 16.4 16.1 15.8 15.5 15.3 15.1 15.0 14.7 14.4 14.1 13.8 COP 4.39 4.20 4.02 3.83 3.70 3.60 3.38 3.12 2.95 2.82 2.74 2.70 2.63 2.44 2.24 2.04 1.84 Hi PR 427 413 400 386 377 372 358 344 330 316 302 294 288 274 261 247 233 LO PR 130 122 114 105 101 97 89 81 73 65 57 52 49 41 33 25 17 Shaded area is AHRI Rating Conditions at 47 degree F outdoor ambient temperature Amps = Outdoor unit amps (comp.+fan) kW =Total system power Daikin Manufacturing Company, L.P. reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. SS-DZ5SE www.daikincomfort.com 19 PERFORMANCE DATA DZSSEA1810A* + AMST30BU1400A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 620 CFM 75 18,850 13,650 5,200 1,100 80 18,650 13,750 4,900 1,160 85 18,400 13,800 4,600 1,220 90 18,000 13,650 4,350 1,290 95 17,600 13,500 4,100 1,350 100 17,100 13,350 3,750 1,430 105 16,600 13,150 3,450 1,500 110 16,150 13,200 2,950 1,590 115 15,700 13,250 2,450 1,670 TVA CONDITIONS @ 95' OD DB, 75° ID DB 63° ID WB 95' 16,950 13,200 3,750 1,350 DZ5SEA3010A* + AMST30BU1400A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1000 CFM 75 30,450 22,350 8,100 1,820 80 30,100 22,450 7,650 1,920 85 29,700 22,550 7,150 2,020 90 29,050 22,350 6,700 2,140 95 00 100 27,600 21,850 5,750 2,380 105 26,800 21,500 5,300 2,500 110 26,100 21,600 4,500 2,650 115 25,350 21,700 3,650 2,790 TVA CONDITIONS @ 95` OD DB, 75° ID DB 63° ID WB 95° 27,400 21,650 5,750 2,250 DZ5SEA4210A*+ AMST42CU1400A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1340 CFM 75 42,900 30,850 12,050 2,500 80 42,400 31,000 11,400 2,640 85 41,850 31,150 10,700 2,780 90 40,950 30,850 10,100 2,940 95 40,000 • I 3,090 100 38,900 30,150 8,750 3,260 105 37,750 29,700 8,050 3,430 110 36,750 29,850 6,900 3,630 115 35,750 29,950 5,800 3,830 TVA CONDITIONS @ 95° OD DB, 75° ID DB 63° ID WB 95° 38,550 29,850 8,700 3,090 DZ5SEA6010A* + AMST60DU1400A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1800 CFM "OUTDOOR TOTAL SENSIBLE LATENT TOTAL 75 60,600 43,350 17,250 3,760 80 59,850 43,550 16,300 4,000 85 59,100 43,750 15,350 4,230 90 57,800 43,350 14,450 4,490 95 II 42,950 13r55O 4,750 100 54,950 42,350 12,600 5,040 105 53,350 41,750 11,600 5,320 110 51,900 41,950 9,950 5,660 115 50,450 42,100 8,350 6,000 TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95° 54,500 42,000 12,500 4,750 DZSSEA2410A*+ AMST30BU1400A* CONDITIONS: 801 IBD, 67 °F IWB @ 800 CFM 75 24,900 17,950 6,950 1,440 80 24,600 18,050 6,550 1,530 85 24,250 18,150 6,100 1,610 90 23,750 18,000 5,750 1,700 95 23,200 17,800 5,400 1,780 100 22,550 17,550 5,000 1,880 105 21,900 17,300 4,600 1,980 110 21,300 17,400 3,900 2,100 115 20,700 17,450 3,250 2,210 TVA CONDITIONS @ 95' OD DB, 75° ID DB 63° ID WB 95' 22,350 17,400 4,950 1,780 DZSSEA3610A*+ AMST42CU1400A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1200 CFM 75 37,800 27,300 10,500 2,170 80 37,350 27,450 9 2,310 85 36,900 27,550 9,,900 350 2,440 90 36,100 27,300 8,800 2,590 95 00 27,000 8,300 2,730 100 34,350 26,650 7,700 2,890 105 33,350 26,250 7,100 3,050 110 32,450 26,350 6,100 3,240 115 31,550 26,400 5,150 3,430 TVA CONDITIONS @ 95' OD DB, 75° ID DB 63° ID WB 95° 34,050 26,400 7,650 2,730 DZ5SEA4810A*+ AMST48CU1400A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1600 CFM 75 49,350 35,900 13,450 2,820 80 48,750 36,050 12,700 2,980 85 48,150 36,200 11,950 3,140 90 47,100 35,850 11,250 3,320 95 46,050 35,500 lot550 3,500 100 44,800 35,000 9,800 3,700 105 43,500 34,450 9,050 3,890 110 42,350 34,600 7,750 4,130 115 41,200 34,700 6,500 4,360 TVA CONDITIONS @ 95° OD DB, 75° ID DB 63° ID WB 95° 44,450 34,700 9,750 3,500 20 www.daikincomfort.com SS-DZ5SE AHRI RATINGS ALL AHRI SYSTEM RATINGS ARE ACCESSIBLE IN THE UNITARY MATCHUP TOOL VIA DAIKIN CITY OR IN THE DAIKIN SYSTEM CONnGURATOR TOOL VIA PARTNERUNK. SS-DZ5SE www.daikincomfort.com 21 DIMENSIONS MODEL DIMENSIONS W„ D„ H„ DZ5SEA1810A* 29 29 39Y2 DZ5SEA2410A* 35Y2 35Y2 35% DZ5SEA3010A* 35Y2 35Y2 39Y2 DZ5SEA3610A* 35Y2 35Y2 39Y2 DZ5SEA4210A* 35Y2 35Y2 35% DZ5SEA4810A* 35Y2 35Y2 36Y2 DZ5SEA6010A* 35Y2 35Y2 41% 22 www.daikincomfort.com SS-DZ5SE (N N 0 Lrl N m BK CONTROLBOX Dc 0 1 YL I PU- � RD BK SR -r2 SZ v 1 L YL Q T1Q T2Q — O l/O' J� yy 11 LIT L2a , ALTERNATE DOUBLE POLE CONTACTOR tyL p YL FBI BK YL- CSM RVC SEENOTE7 DFT Hi - CM HPS BUPK-5t BL/PK �RI( SC BKF K RD BL T1 T2 I LL1n R L2 1 BK RD PU YL - -BR IYL/PK SEE NOTE YUPK LPS CH RID- i C F RCCF I YL L I YL SA (IF USED NOTE 2 RD EQUIPMENT GROUND SEE NOTE 3 LVJB -OR 0 SEE NOTE 1 -WH W2 SEENOTE3 -RD R - PU Y - BL C COLOR CODE BK--------------- BLACK BUPK---------- BLUE/PINK STRIPE BR --------------- BROWN GR ---------------- GREEN OR ---------- --- ORANGE PU--------------- PURPLE RD--------------- RED W H----------- WHITE YL--------------- YELLOW YL/PK ----------- YELLOW/PINK STRIPE WIRING CODE FACTORY W IRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE COMPONENTCODE C--------------- CONTACTOR CSM--------- CORESENSE MODULE CCR----------- COMPRESSOR CONTACTOR RELAY CH ------------- CRANKCASE HEATER CHS----------- CRANKCASE HEATER SWITCH CM --------- OUTDOOR FAN MOTOR COMP -------- COMPRESSOR DC ------------- DEFROST CONTROL DFT--------- DEFROST THERMOSTAT DT -------------- DISCHARGE THERMOSTAT HIPS ----------- HIGH PRESSURE SWITCH HVDR-------- HIGH VOLTAGE DEFROST RELAY 10-------------- INTERNAL OVERLOAD LPS---------- LOW PRESSURE SWITCH LVDR-------- LOW VOLTAGE DEFROST RELAY LVJB--------- LOW VOLTAGE JUNCTION BOX RCCF--------- RUN CAPACITOR FOR COMPRESSOR & FAN RVC----------- REVERSING VALVE COIL SA ------------- START ASSIST SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. OUTDOOR POWER SUPPLY SEE RATING PLATE SEE NOTE 3 T1 T2 L1 �� C 5 SR 2 1 SC C CSM U Lu m O 10 PJ S RCCF 0 OIMP 00 1 IDF1 c o ~ HVDR �qGy R I F aF I DF2 cc w 00 (IF USED) aLu NOTE 2 O a 10 PJ� CM �q2� CHS CH SEE NOTE 4 DFT o-r. DFT DC Fr R-PS1 PS2 y LVDR J LPS 0-1`V RVC C-RV 11-0 0 CNT HIPS C C FIELD LOW W2 0 Y VOLTAGE -INDOOR POWER SUPPLY CONNECTION SEE NOTE 5 & 6 SEE NOTE 3 SEE NOTE 1 NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR THERMOSTAT. GR USE N.E.C. CLASS 2 WIRE. 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTOR ONLY. 4) CRANKCASE HEATER & CRANKCASE HEATER SWITCH ARE FACTORY INSTALLED OPTION. 5) 40VA MINIMUM TRANSFORMER IS REQUIRED. 6) COMMON SIDE OF TRANSFORMER MUST BE GROUNDED. 7) ENSURE BLACK COMPRESSOR WIRE IS ROUTED THROUGH THE HOLE IN THE CSM. 0140R00799-B Wiring is subject to change. Always High loltage., Disconnect all power before servicing or installing this unit. Multiple power L refer to the wiring diagram on the I % WARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. w unit for the most up-to-date wiring. N A N N LrI m CONTROLBOX DC 1 o RD I BK WH CL ry BR YL BK CM RD r L LVJB OR 0 SEE NOTE 1 OUTDOOR POWER SUPPLY SEE RATING PLATE WH W2 SEENOTE3 T� SEE NOTE T2 RD RD R L� L PU Y C 5 SR 2 SC C BL C H C COLOR CODE pt z 10 p' S RCCF BL BK --------------- BLACK m 0 COMP DT BUPK---------- BLUE/PINK STRIPE 000 c BKBK BR --------------- BROWN wU DH'VDR �q�'Y R L. GR ---------------- GREEN zz DF2 OR --------------- ORANGE w a PU--------------- PURPLE t w sA RD--------------- RED ¢ O I (IF USED) NOTE 2 WH----------- WHITE a BL/PK YL--------------- YELLOW CM PU YL/PK ----------- YELLOW/PINK STRIPE SC WIRING CODE FACTORY W IRING GR HIGH VOLTAGE y LOW VOLTAGE OPTIONAL HIGH VOLTAGE -CHHSS CH o�. o l- RD BL FIELD WIRING l SEE NCO 4 T1 L1 YL - —BF f)RD BKI y IYUPK SEENOTE4 YUPK LP IHIGH VOLTAGE— — nF D COMPONENT CODE RD C--------------- CONTACTOR DFT CSM------- CORESENSE MODULE tH CCR----------- COMPRESSOR CONTACTOR RELAY R-DFT DFT DC BR CH ----------- CRANKCASE HEATER R-PSI PS2 y RD CHS----------CRANKCASE HEATER SWITCH RD- CM --------- OUTDOORFANMOTOR LVDR COMP -------- COMPRESSOR R LPS 0-RV C OF RCCF DC ----------- DEFROST CONTROL DFT----------- DEFROST THERMOSTAT 0 • YL DT -------------- DISCHARGE THERMOSTAT CNT HPS C YL HIPS ----------- HIGH PRESSURE SWITCH HVDR-------- HIGH VOLTAGE DEFROST RELAY CCR DT SA 10-------------- INTERNAL OVERLOAD CSM (IF USED) V LPS--------- LOW PRESSURE SWITCH ev R Y C P NOTE2 LVDR--------- LOW VOLTAGE DEFROST RELAY LVJB--------- LOW VOLTAGE JUNCTION BOX R RCCF--------- RUN CAPACITOR FOR COMPRESSOR & FAN � RVC----------- REVERSING VALVE COIL W2 o Y SA -------------START ASSIST �INDOOR POWER SUPPLY + BK — SC ------------- START CAPACITOR FOR COMPRESSOR SEE NOTE 5 & 6 (OPTIONAL) SEE NOTE 3 SEE NOTE 1 EQUIPMENT GROUND SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) CH SEE NOTE 3 CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR THERMOSTAT. GR USE N.E.C. CLASS 2 WIRE. 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. _ 3) USE COPPER CONDUCTOR ONLY. S 4) CRANKCASE HEATER & CRANKCASE HEATER SWITCH ARE FACTORY INSTALLED OPTION. 5) 40VA MINIMUM TRANSFORMER IS REQUIRED. 6) COMMON SIDE OF TRANSFORMER MUST BE GROUNDED. 7) ENSURE BLACK COMPRESSOR WIRE IS ROUTED THROUGH THE HOLE IN THE CSM. Wiring is subject to change. Always High Voitage. Disconnect all power before servicing or installing this unit. Multiple power L refer to the wiring diagram on the 7 WARNING I ources may be present. Failure to do so may cause property damage, personal injury, or death. unit for the most up-to-date wiring. FIELD LOW VOLTAGE 0140R00828-B No (N (n 0 Lrl Ln M N CONTROLBOx LVJB RD OUTDOOR POWER SUPPLY OR-0 SEE RATING PLATE WH—w2 SEENOTE4 SEE NOTE RD RD—R SEE NOTE DC RD PU—v BK P DF1 R BL—C n _ ^J �_,�yI`�_F2 r r YL-y2 L1 - 1 "� L2 DF2 I D I r I R BL BK 5 SR L 1 SC C RD OFT J I c , T5 C q CMR CSM IO H C RD R DFf ol RP31 C W c P RCCF BK RD m C Cane BL vL 2 5 COLOR CODE 0 � DF1 Mq F 1 1 3 BK------------- BLACK 0 HVDR R J BL BL BUPK-------- BLUE/PINK STRIPE w a DF2 r BR --------------- BROWN z 0 YUPK YL WH BK BK OR BL/PK OR ---------------ORANGE w L SA J RD J j I (IF USED) ' RD BL PU--------------- PURPLE < O NOTE 2 RD------------ RED a RD YUPK WH -------------- WHITE YL--------------- YELLOW �i- sc YUPK----------- YELLOW/PINK STRIPE 2 (HIGH) IO P YUPK BK CMR WIRING CODE cm �qti BK BK FACTORYWIRING 4 5 BLiPK RD RD B_L HIGH VOLTAGE CHS LOW VOLTAGE c" BK sR FU T1 i OPTIONAL HIGH VOLTAGE SEE NOTE6 BK L1 L2 RD FIELDWIRING PU I;BL-- c HIGHVOLTAGE — R."DDFI. BL BKRD LOW VOLTAGE — —� S2 Y CMR RD COMPONENT CODE 1 3 BL C --------------- CONTACTOR c PU H C F CCR--------- COMPRESSOR CONTACTOR RELAYO-RV C-Rv BK I RCCF CH ------------ CRANKCASE HEATER 1 CHS--------- CRANKCASE HEATER SWITCH p r1p rz0 — BR — — CM----------- OUTDOOR FAN MOTOR Vy CN C 1J0,/A 1 1 YL YL CMR---------- CONDENSER MOTOR RELAY L1a Lea lYL� COMP------- COMPRESSOR CCR R P v SA CS----------- COMPRESSOR SOLENOID HP ALTERNATE (IFUSED) IN Y2 C CSM DOUBLE POLE NOTE 2 CSM-------- CORESENSE MODULE R Y C P COMACRQU RD Rp DC ------------ DEFROST CONTROL DT SEE NOTE SEE NOTE BK BK� SEE NOTE6 DFT----------- DEFROST THERMOSTAT DT---------- DISCHARGE THERMOSTAT R W Y Y FIELD LOW _ HPS----------- HIGH PRESSURE SWITCH EQUIPMENT SEE NOTE 1 VOLTAGE DFT BUPK cHsJRGROUND HVDR-------- HIGH VOLTAGE DEFROST RELAY CONNECTIONS RD^�.�5� RD NOTE IO-------------- INTERNAL OVERLOAD INDOOR POWER SUPPLY L RD HPs BL/P UPS ---------- LOW PRESSURE SWITCH NOTES: BK DT CH LVDR------- LOW VOLTAGE DEFROST RELAY 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL LVJB ---------- LOW VOLTAGE JUNCTION BOX BLOCK AND INDOOR THERMOSTAT. RVCRCCF-------- RUN CAPACITOR FOR COMPRESSOR & FAN BK YL COMP USE N.E.C. CLASS 2 WIRE. BK MAIN RVC __________ REVERSING VALVE COIL 2) START ASSIST FACTORY EQUIPPED WHEN R SA---------- START ASSIST REQUIRED. J YUPK Aux SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) 3) THE COMMON SIDE OF LOW VOLTAGE SHALL PU Cs 1 SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) NOT BE GROUNDED. 4) USE COPPER CONDUCTOR ONLY. BR YUPK CONTROLS SHOW N W ITH THERMOSTAT IN'OFF' POSITION. 5) CRANKCASE HEATER MAY NOT 1� HAVE ADDITIONAL GROUND WIRE. BKC S6) CRANKCASE HEATER & CRANKCASE HIGH) HEATER SWITCH ARE FACTORY UPS INSTALLED OPTION.RD R 7) ENSURE BLACK COMPRESSOR WIRE IS (LOW) ROUTED THROUGH THE HOLE IN THE CSM. 0140R00377-C Wiring is subject to change. Always High VoMoge: Disconnect all power before servicing or installing this unit. Multiple power L refer to the wiring diagram on the 7 WARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. unit for the most up-to-date wiring. ) ACCESSORIES .0 ABK-20 Anchor Bracket Kit' X X X X X X X CSR-U-1 Hard -start Kit X X X X CSR-U-2 Hard -start Kit X X X CSR-U-3 Hard -start Kit X X FSK01A' Freeze Protection Kit X X X X X X X LAKT01A Low -Ambient Kit X X X X X X OT18-60A2 Outdoor Thermostat X X X X X X X w/ Lockout Stat TXV-FX-KX-2T 3 TXV Kit X X TXV-FX-KX-3T 3 TXV Kit X X TXV-FX-KX-5T 3 TXV Kit X X X 0 Contains 20 brackets; four brackets needed to anchor unit to pad ' Installed on indoor coil z Required for heat pump applications where ambient temperatures fall below 0°F with 50%or higher relative humidity. a Condensing units and heat pumps with reciprocating or rotary compressors require the use of start -assist components when used in conjunction with an indoor coil using a non -bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit. The TXV should always be sized based on the tonnage of the outdoor unit. 26 www.daikincomfort.com SS-DZ5SE NOTES SS-DZ5SE www.daikincomfort.com 27 NoTEs Our continuing commitment to quality products may mean a change in specifications without notice. 02023 OA/K/NCOMFORTTECHNOLOO/ESMANUFACTURMNG.L.P. • Houston, Texas • Printed in the USA. 28 www.daikincomfort.com SS-DZ5SE