Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED RESUB1 FIR2022-0110+Fire_Alarm_Plan+11.29.2022_1.10.03_PM+3242261
C", c/` Port of Edmonds Administration Building 471 Admiral Way Edmonds., WA 98020 VICINTY MAP 0 N ti r •is•Y cht club �1 Pori of Edmonds Is Yacht Sales I Boat dealer Puget4iJfEd Yacht Service AWtho ys A Edmonds Seafood- M LOCATION MAP r„ FIRE ALARM SYSTEM BILL OF MATERIALS a Lo 4j 19 Jac❑bsens Pia Bcat dealer FA SYMBOL LEGEND FIRE ALARM PARTS LIST SYMBOL FACP DESCRIPTION FIRE ALARM CONTROL PANEL PART NUMBER 6700 FAA ANNUNCIATOR 586OG RADIO DIGITAL COMMUNICATOR TRANSMITTER 7707P-88-ULP-M FNACI N POWER SUPPLY BOOSTER PANEL 5496 PULL STATION, SINGLE ACTION, ADDRESSABLE SK-PULL-SA �s SMOKE, PHOTOELECTRIC, ADDRESSABLE 135 °F (57° C) DUAL CIRCUIT FIXED TEMPERATURE and RATE OF RISE MOUNTED IN PIT 135 °F (57' C) DUAL CIRCUIT FIXED TEMPERATURE MOUNTED ON TOP OF ELEVATOR SHAFT SK-PHOTO-W 5621 5623 0135°F 0 FIX/RR W ISOLATION MODULE SK-ISO MM MONITOR MODULE SK-MONITOR MD DUAL MONITOR MODULE SK-MONITOR 2 DR DUAL RELAY MODULE SK-RELAYMON 2 RM RELAY MODULE HORN/STROBE, 2 WIRE, M-C, RED, OUTDOOR STROBE, 2 WIRE, L-SERIES, WHITE, WALL SK-RELAY P2RK SWL WPCD HVK �o ❑� 1,N1PCD STROBE, 2 WIRE, L-SERIES, RED, WALL, OUTDOOR SRK HORN/STROBE, 2 WIRE, M-C, WHITE, WALL P2WL H HORN/STROBE, 2 WIRE, M-C, WHITE, CEILING PC2WL ROOM LOW TEMP SWITCH, N.O. BAF FAN WIRE GUARD FOR NOTIFICATION DEVICES RTS-0 BAF CF-2 BY OTHERS TBD WG FIRE ALARM SYSTEM BOM MOUNTING HEIGHT / QTY DESCRIPTION MANUFACTURER MODEL NUMBER MOUNTING BOX NOTES 1 MAIN BOARD w/ 6700 B CARD SILENT KNIGHT 6700 SUPPLIED 72" TO TOP 2 BATTERY 12V 7AH SILENT KNIGHT BAT-1270 - FACP BATTERIES 1 DIGITAL COMMUNICATOR TRANSMITTER AES 7707P-88-ULP-M SUPPLIED SUPPLIED 1 BATTERY 12V 10AH SILENT KNIGHT BAT-12100 - AES BATTERY LCD REMOTE ANNUNCIATOR, 80 CHAR 1 DISPLAY, RED BEZEL SILENT KNIGHT 5860G SUPPLIED AS REQUIRED 1 POWER SUPPLY NAC CIRCUITS SILENT KNIGHT 5496 SUPPLIED 72" TO TOP POWER SUPPLY 2 BATTERY 12V 7AH SILENT KNIGHT BAT-1270 _ BATTERIES PULL STATION, SINGLE ACTION, 1 SILENT KNIGHT SK-PULL-SA 1 GANG 48" TO TOP ADDRESSABLE SMOKE, PHOTOELECTRIC, ADDRESSABLE 5 SILENT KNIGHT SK-PHOTO-W 3-ROUND CEILING w/BASE B300-6 PROVIDED 135 °F (57° C) DUAL CIRCUIT FIXED w/IN 24" OF SPRINKLER 2 SYSTEM SENSOR 5623 3-ROUND BOX TEMPERATURE HEAD 1 135 °F (57° C) FIXED, ROR, DUAL CIRCUIT SYSTEM SENSOR 5621 3-ROUND BOX w/IN 24" OF SPRINKLER HEAD 2 ISOLATION MODULE DUAL RELAY MODULE SYSTEM SENSOR SILENT KNIGHT SK-ISO SK-RELAYMON-2 4-SQUARE BOX 4-SQUARE BOX AS REQUIRED AS REQUIRED 2 3 RELAY MODULE SILENT KNIGHT SK-RELAY 4-SQUARE BOX AS REQUIRED 6 DUAL MONITOR MODULE SILENT KNIGHT SK-MONITOR 2 4-SQUARE BOX AS REQUIRED 5 MONITOR MODULE SILENT KNIGHT SK-MONITOR 4-SQUARE BOX AS REQUIRED HORN TROBE, WI , M-C, R D, 1 SYSTEM SENSOR P2RK SUPPLIED 80" TO BOTTOM OUTDOOR STROBE, 2 WIRE, L-SERIES, WHITE, WALL SYSTEM SENSOR 1-GANG BOX 80" TO BOTTOM 6 SWL STROBE, 2 WIRE, L-SERIES, RED, WALL, 1 SYSTEM SENSOR SRK 1-GANG BOX 80" TO BOTTOM WEATHPROOF 12 HORN/STROBE, 2 WIRE, M-C, WHITE, WALL SYSTEM SENSOR P2WL 1-GANG BOX 80" TO BOTTOM HORN/STROBE, 2 WIRE, M-C, WHITE, 8 SYSTEM SENSOR PC2WL 1-GANG BOX 80" TO BOTTOM CEILING 1 ROOM LOW TEMP SWITCH, N.O. POTTER ELEC. CO. RTS-0 1-GANG BOX AS REQUIRED 5 WIRE GUARD TBD TBD TBD TBD 1 DOCUMENT BOX SDB SS000691 SUPPLIED AS REQUIRED GENERAL NOTES 1. INSTALL A NEW ADDRESSABLE SILENT KNIGHT 6700 FIRE ALARM PANEL IN NEW PORT OF EDMONDS BUILDING PER NFPA 72 2016, 2018 IBC, AND 2018 IFC. 2. ALL WIRE IS TO BE INSTALLED IN ELECTRICAL METALLIC TUBING (EMT) EXCEPT; SUITABLE CABLES RUN "OPEN" IN ACCESSIBLE LOCATIONS ABOVE CEILING OR WITHIN ATTIC SPACE. 3. CONDUIT IS TO BE PROVIDED AND INSTALLED BY OTHERS. 4. CORE DRILLING REQUIRED TO FACILITATE ALL CONDUIT WORK. CORE DRILLED HOLES SHALL NOT PENETRATE THROUGH ANY STRUCTURAL BEAMS, REBAR AND/OR CONDUIT CONTAINED WITHIN THE CONCRETE SLABS AND/OR WALLS THAT MAY COMPROMISE THE STRUCTURAL INTEGRITY OF THE BUILDING. CORE DRILL LOCATION MAY NEED TO BE ADJUSTED TO ACCOMMODATE OBSTRUCTIONS. PRIOR TO DRILLING COORDINATE EXACT LOCATIONS OF HOLES WITH GENERAL CONTRACTOR. 5. THIS DRAWING SHOWS THE LAYOUT OF THE FIRE ALARM SYSTEM AND INDICATES THE APPROXIMATE LOCATION OF EQUIPMENT, WIRING, AND CONDUIT. WIRING AND CONDUIT ARE SHOWN POINT TO POINT ONLY. THE CONDUIT IS TO BE INSTALLED IN APPROXIMATELY THE AREA AS INDICATED ON THE DRAWINGS; HOWEVER, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MODIFICATIONS AS MAY BE REQUIRED TO SUIT STRUCTURAL OR JOB CONDITIONS. THE CONTRACTOR SHALL FURNISH ALL OFFSETS, ADDITIONAL MATERIAL, CONDUIT ADJUSTMENTS, ETC. AS MAY BE REQUIRED TO MEET INSTALLATION CONDITIONS. ACTUAL WIRE RUNS SHALL BE KEPT IN AN ORGANIZED MANOR BY THE INSTALLING CONTRACTOR TO FACILITATE AS -BUILT DRAWINGS. 6. PRIOR TO ROUGH -IN COORDINATE THE EXACT LOCATIONS OF FIRE ALARM EQUIPMENT, DEVICES, AND CONDUIT WITH THE ELECTRICAL, MECHANICAL, AND FIRE PROTECTION CONTRACTORS. 7. THE CONTRACTOR IS TO REVIEW AND VERIFY ALL FIELD CONDITIONS, MEASUREMENTS, PLANS, AND STOCK LISTS, PRIOR TO ORDERING, FABRICATION, AND INSTALLING. SECURITY SOLUTIONS NW WILL NOT ASSUME THE RESPONSIBILITY OF THE ALARM COMPONENTS OR CONDUIT FITTING PER PLAN. 8. THE FIRE ALARM SYSTEM CONTRACTOR AND GENERAL CONTRACTOR SHALL COORDINATE ALL CUTTING, PATCHING, AND FINISH WORK. 9. ALL ALARM WIRING IS TO BE IN ACCORDANCE WITH NFPA 72 2016ED. 10. NAC PATHWAY CLASS DESIGNATIONS: NFPA 72, CLASS A 11. SLC PATHWAY CLASS DESIGNATIONS: NFPA 72, CLASS A 12. PENETRATIONS THROUGH FIRE RATED PARTITIONS TO BE SEALED BY OTHERS TO MAINTAIN THE INTEGRITY OF THE PARTITION. 13. MOUNT PULL STATIONS WITHIN 60" OF THE LATCH SIDE OF THE EXIT DOORWAY AND BETWEEN 42" AND 48" ABOVE FLOOR LEVEL. ALL DEVICES SHALL BE MOUNTED AT THE SAME HEIGHT. 14. LOCATE SMOKE AND HEAT DETECTORS NOT CLOSER THAN 36" FROM AIR -SUPPLY DIFFUSER OR RETURN -AIR OPENINGS. 15. LOCATE DETECTORS NOT CLOSER THAN 12" FROM ANY PART OF A LIGHTING FIXTURE AND NOT DIRECTLY ABOVE PENDANT MOUNTED OR INDIRECT LIGHTING. 16. INSTALL A COVER ON EACH SMOKE DETECTOR THAT IS NOT PLACED IN SERVICE DURING CONSTRUCTION. COVER SHALL REMAIN IN PLACE EXCEPT DURING SYSTEM TESTING. 17. AUDIBLE/VISUAL ALARM INDICATION DEVICES SHALL BE INSTALLED NOT LESS THAN 6" BELOW THE CEILING BETWEEN 80" AND 96" ABOVE FLOOR LEVEL. INSTALL HORN/STROBES ON FLUSH MOUNTED BACK BOXES. ALL DEVICES SHALL BE MOUNTED AT THE SAME HEIGHT. 18. AUDIBLE ALARM INDICATION DEVICES SHALL BE INSTALLED NOT LESS THAN 90" ABOVE THE FLOOR AND NOT LESS THAN 6" BELOW THE CEILING. ALL DEVICES SHALL BE MOUNTED AT THE SAME HEIGHT. 19. SLC, POTS, NAC, SBUS, AND RELAY CIRCUITS CONNECTED TO FIRE ALARM PANEL SHALL BE RUN IN SEPARATE RACEWAYS PER MANUFACTURERS SPECIFICATIONS TO AVOID INDUCED NOISE. 20. VERIFY AND COORDINATE WITH ELECTRICAL CONTRACTOR THE DEDICATED CIRCUIT FOR FACP. 21. WIRE BETWEEN ANTENNA (IF USED) AND RADIO ALARM TRANSMITTER SHALL BE INSTALLED IN CONDUIT. 22. VERIFY ALL SITE CONDITIONS, ARCHITECTURAL, MECHANICAL, AND SPRINKLER PLANS PRIOR TO ROUGH -IN FOR ALL DEVICES. VERIFY ALL LOCATIONS PRIOR TO INSTALLATION WITH GENERAL AND THE ELECTRICAL CONTRACTOR. 23. PROVIDE WIRE GUARDS FOR DEVICES IN BAY AREAS. VERIFY TYPES AND COLORS WITH ARCHITECT. 24. CONTRACTOR SHALL PERFORM AND MEET ALL CODE REQUIRED TESTS, AND FILE A MATERIALS TEST CERTIFICATE PER NFPA 72 2016ED. 25. FIRE ALARM ACCEPTANCE TESTING TO BE SCHEDULED WITH THE BASE FIRE PREVENTION OFFICE A MINIMUM OF (14) WORKING DAYS IN ADVANCE. FIRE ALARM CONTRACTOR MUST COMPLETE PRE -ACCEPTANCE TESTING AND CORRECTIONS PRIOR TO ACCEPTANCE TESTING. ALL WORK SHALL BE APPROVED BY THE AUTHORITIES HAVING JURISDICTION. 26. PROVIDE ISOLATION MODULES FOR THE CLASS 'A' SEND AND RETURN OF THE SLC LOOP. LOCATE DEVICES IN THE ELECTRICAL ROOM, NEXT TO THE FACP. CABLE/CONDUIT NOTES 1. ALL SIGNAL LINE, INITIATING, AND NOTIFICATION CIRCUITS SHALL BE "CLASS B" WIRING. 2. ALL NOTIFICATION APPLIANCE CIRCUITS SHALL BE Approved A MINIMUM OF (#14) GAUGE. DFM Ct County ty South Coaunty Fire F 3. ALL SIGNAL LINE AND INITIATING DEVICE CIRCUITS Date:12/08/2022 SHALL BE A MINIMUM OF (#18) GAUGE. 12-08-2022 4. ALL WIRE RUN UNDERGROUND SHALL BE SUITABLE PLAN REVIEW FOR "WET" INSTALLATIONS. NOTES: APPROVED 5. ALL WIRE TERMINATIONS SHALL BE AT TERMINAL DFM BURT STRIPS WITH SCREW CONNECTIONS. 6. THE USE OF WIRE NUTS, CRIMPED CONNECTORS, TWISTING OF WIRES, ETC. SHALL BE ALLOWED IN J-BOXES. ALL WIRES OUTSIDE OF J-BOXES SHALL BE FREE OF SPLICES. 7. ALL FIRE ALARM CABLING SHALL BE INSTALLED IN DEDICATED CONDUIT EXCEPT, SUITABLE CABLES RUN "OPEN" IN ACCESSIBLE LOCATIONS ABOVE CEILINGS OR WITHIN THE ATTIC SPACE. 8. CLASS'A' CIRCUIT RETURN TO BE SEPARATED BY 12" ON VERTICLE RUNS AND 48" ON HORIZONTAL RUNS. DRAWING INDEX SHEET DESCRIPTION FA.0.01 DRAWING INDEX, LEGEND, BOM, AND NOTES FA.1.01 FIRST FLOOR PLAN FA.1.02 SECOND FLOOR PLAN FA.1.03 RISER, MECHANICAL, ELEVATOR MACHINE ROOMS ENLARGED PLANS ELEVATIONS AND SECTIONS FA.1.04 FA.2.01 RISER DIAGRAM CLASS W FA.3.01 PANEL SCHEDULES AND CALCULATIONS FA.4.01 AES 7707P COMMUNICATOR, 5860G ANNUNCIATOR, AND DETAILS FA.4.02 FIRE ALARM DEVICE DETAILS FA.4.03 FACP 6700, 5860 ANNUNCIATOR, PS 5496 AND DEVICES FA.5.01 MATRIX SEQUENCE OF OPERATION z 0 U H U) z 0 U 0 LL Lu Z) rn L N N 0 00 U) z 0 w J Q U) Q Lu LL De cn w LL cl� - O J U�a J z wc::) J J W MU) m ti� W Q 0 z 0 U Ln IU 0 Ln (V (V 00 O O W Lin QQ rn I_ V) ran . < "': o�VQ0Q0 z M M 1-0 W m F I R2022-0110 RESUB Nov 29 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVIEWED BY: C. RUSSELL �NICET LEVEL III CERT NO. 120520LEVEL III CERT NO. 120520 0 Z O 2i U) 0 � W 0 LL z O o � Z Q O 0- O O N o 0 W Q 00 z � > 0)W CD > J Q w cn NQ � X z N z W o C- p Q a C 0 Z w 0 0 Z N C� a QLL < O w Z z Q - W w 0 w w can LL a W a DRAWING SIZE: E SIZE 30"x42" DRAWN BY: J. LUCHSINGER DATE DRAWN: 10/07/2022 REV DATE: 11/28/2022 REV 2 BUSINESS LICENSE # SECURSN790NE ELECTRICAL LICENSE # SECURSN954JG FA. 0.01 FLAG NOTES 0 CO CABLE/CIRCUITING SCHEDULE a 0 EXTERIOR HORN STROBE LOCATION TO BE APPROVED BY AHJ. VERIFY MOUNTING LOCATION ON AS -BUILT DWGS. C P1:SIG1.01 11( O O O 1� CONTRACTOR WILL PROVIDE SURGE PROTECTION FOR ALL WIRING TO DEVICES THAT ARE LOCATED ON EXTERIOR/OUTSIDE WALLS. VERIFY WITH AHJ EXACT LOCATION OF OUTSIDE HORN STROBE. PROVIDE WEATHERPROOF ENCLOSURE FOR EXTERIOR DEVICES, TYPICAL. ® VERIFY ALL LOCATIONS OF MODULES FOR SPRINKLER RISER SYSTEM. SHOULD DEVICE COUNT CHANGE ADD LOCATION AND ADDRESSES ON AS -BUILT DRAWINGS. VERIFY ON -SITE CONDITIONS FOR EXTERIOR COMMUNICATOR ANTENNA IF NEEDED. © PROVIDE RED PLASTIC PULL STATION SIGN WITH 1" HIGH WHITE ENGRAVED LETTERS AND MOUNTED ABOVE PULL STATION. SIGN SHALL SAY THE FOLLOWING: "IT IS THE RESPONSIBILITY OF ANYONE PLACING THIS FIRE ALARM SYSTEM INTO TEST TO INFORM THE MONITORING STATION TO NOT PLACE THE FACP PULL STATION INTO TEST. THIS POINT MUST STAY ACTIVE." 7= WA L&I - IF SPRINKLER IS PRESENT. PROVIDE HEAT (5621 Fixed & ROR) DETECTOR AT BOTTOM OF SHAFT FOR SECONDARY LEVEL RECALL AND FLASH HAT (FLASHING) ACTIVATION. INSTALL w/IN 24" SPRINKLER. 8� DEDICATED CIRCUIT BREAKER FOR FIRE ALARM SYSTEM PROVIDED BY OTHERS & LOCATED IN ELECTRICAL ROOM 9:> STROBE ONLY DUE TO VICINITY OF RATH TWO-WAY COMMUNICATION STATION. 0> FAN SHUTDOWN RELAYS PROVIDED FOR BAF CE-2, CE-3, AND CE-4 FANS. COORDINATE RELAY LOCATION WITH EACH CONTROLLER, FINAL CONNECTIONS BY OTHERS. CABLE TYPES: SILENT KNIGHT 6700 Source Circuit Circuit Type Circuit Abbr Wiring Style Symbol Type Description Gauge Color 6700/5496 NAC Notification V Class B Fire Alarm 14/2 SOL JKT FPLP I RL RED #14 Red 6700 SLC Signaling line U Class B Fire Alarm 18/2 SOL JKT FPLR 1 M RL RED #18 Black 6700 IDC Initiating Z Class B Fire Alarm 18/2 SOL JKT FPLR 1 M RL RED #18 Red 6700 SBUS Power/Serial P Class B Fire Alarm 18/4 SOL JKT FPLR 1M RL RED #18 Red FIRST FLOOR PLAN 0 N SCALE: 1 /4" = V-0" M 0 5 10 15 20 11 z 0 O z O U U) ry w U) ry z J O a U 2 co O ry 0 a LL 2i 7) W U L U_ C/) LU LL O 0 0 J UZD J z W O J J Ul C/) W m tipw z O a U w LI1 (V 00 O O w CY) � Q a�a, ��Ir; L,e) M ,Ql�tfl Z = O O a1V1-0Q0 z M M L4-: r J L1J m F I R2022-0110 RESUB Nov 29 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVIEWED BY: C. RUSSELL NICET LEVEL III CERT NO. 120520 1 v J 0 Z OC G 0 LU LLJ a w I— un Ln z O O LL z I- U LLJ 0 1 Q z O a U 1-11 LLB 0 U LU 0 CL DRAWING SIZE. E SIZE 30"x42" DRAWN BY: J. LUCHSINGER DATE DRAWN: 10/07/2022 REV DATE: 11/28/2022 REV 2 BUSINESS LICENSE # SECURSN790NE ELECTRICAL LICENSE # SECURSN954JG z Q O O J LL U) LL FA.1.01 N N O O N UJI O CO FLAG NOTES CABLE/CIRCUITING SCHEDULE 1� CONTRACTOR WILL PROVIDE SURGE PROTECTION FOR ALL WIRING TO DEVICES THAT ARE LOCATED ON EXTERIOR/OUTSIDE WALLS. CABLE TYPES: SILENT KNIGHT 6700 VERIFY WITH AHJ EXACT LOCATION OF OUTSIDE HORN STROBE. PROVIDE WEATHERPROOF ENCLOSURE FOR EXTERIOR DEVICES, TYPICAL. ® VERIFY ALL LOCATIONS OF MODULES FOR SPRINKLER RISER SYSTEM. SHOULD DEVICE COUNT CHANGE ADD LOCATION AND ADDRESSES ON AS -BUILT DRAWINGS. VERIFY ON -SITE CONDITIONS FOR EXTERIOR COMMUNICATOR ANTENNA IF NEEDED. © PROVIDE RED PLASTIC PULL STATION SIGN WITH 1" HIGH WHITE ENGRAVED LETTERS AND MOUNTED ABOVE PULL STATION. SIGN SHALL SAY THE FOLLOWING: "IT IS THE RESPONSIBILITY OF ANYONE PLACING THIS FIRE ALARM SYSTEM INTO TEST TO INFORM THE MONITORING STATION TO NOT PLACE THE FACP PULL STATION INTO TEST. THIS POINT MUST STAY ACTIVE." 7= WA L&I - IF SPRINKLER IS PRESENT. PROVIDE HEAT (5621 Fixed & ROR) DETECTOR AT BOTTOM OF SHAFT FOR SECONDARY LEVEL RECALL AND FLASH HAT (FLASHING) ACTIVATION. INSTALL w/IN 24" SPRINKLER. 8� DEDICATED CIRCUIT BREAKER FOR FIRE ALARM SYSTEM PROVIDED BY OTHERS & LOCATED IN ELECTRICAL ROOM STROBE ONLY DUE TO VICINITY OF RATH TWO-WAY COMMUNICATION STATION. FAN SHUTDOWN RELAYS PROVIDED FOR BAF CE-2, CE-3, AND CE-4 FANS. COORDINATE RELAY LOCATION WITH EACH CONTROLLER, FINAL CONNECTIONS BY OTHERS. z W O z O U U) w U O Q U 2 z Of C0 O OLL a w 22 7) W U w Lo li p � N � A2 N 110CD WP H P2:SIG3 0 6 LL 0 0 RECEPTION/ CD OFFICE 6 OFFICE 5 OFFICE 4 OFFICE 3 OFFICE 2 OFFICE 1_ N 206 205 204 203 202 201 O 00 CD 0 M�- _j wa'Mn Q<�� 30CD ZD a �2`"'� U = H J (D z=�� z z M M P2:SIG3.005 CD � J � m m H 15CD H 15CD Ul P2:SIG3 002 P2: ARCHIVE • SIG3.004 ROOM _ ❑ 209 AUDIT p SERVER COMMISSION MTG ROOM 211 15CD 212 LOBBY F I R2022-0110 H 218 o j g 200 1 P O TOR SHAFT P2:SIG3.003 TO ISO IN 97S : 2 97S•S:004 ELECTRICAL RO MM S RESUB E � 0 H 15CD NOTIFICATION CIRCUIT H P2:SIG3.011 CITY Nov OF EDMONDS 2022 TO AND FROM LEVEL 1 DEVELOPMENT SERVICES 15CD M M DEPARTMENT P2:SIG3.001 5CD � 2:SIG3.015 c 9 ,O :SIG3.007 ° 7S M:028 EXTEND TO O ISO VLV LEVEL,1 SLC LOOP 15CD MEWS R.R. PROVIDE SMOKE AN EQUIPMENT 213 FIXED WITH RELAY) E CTORATTHE O O S A T REVIEWED BY: C. RUSSELL FOR ELEVATOR REC L AND SHUNT TR P C VATIC N, NICET LEVEL III CERT NO. 120520 PLATFORM IF SPRINKLER IS PRESENT. SEE FLOOR L N FOR 221 tj ADDRESSES. PROVI E SMOKE DETEC F R P2:SIG3.014 ELEVATOR RECALL I SMOKE RELI PRESENT. INSTALL E DETECTOF OF ",[H E:1 SPRINKLER HEAD IF SENT. 15CD 0 ❑ ❑ z O WOMEN'S R.RH 30CD 2i 0 15CD P2:SIG3.008 _ p LU ° P2:SIG3.013 L LL H P2:SIG3.010 o Q 0 CUSTDIAL 15CD � L?i5 \ � O O LLl Q 00 cj > 0) z >- _j Q Q 15CD ° H P2:SIG3.012 o z O C1) o LEASEABLE Q 0 a BREAK ROOM STORAGE 30CD OFFICE z F LL H P2:SIG3.009 u 216 219 217 Q z Q O o z o � � w W w w 0 o 0 o w L.L_ LU CL U) ❑ DRAWING SIZE: E SIZE 30"x42" DRAWN BY: J. LUCHSINGER DATE DRAWN: 10/07/2022 REV DATE: 11/28/2022 REV 2 BUSINESS LICENSE # SECOND FLOOR PLAN N SECURSN790NE SCALE: 1/4" = V-0"0 ELECTRICAL LICENSE # SECURSN954JG 0 5 10 15 20 FA. 1.02 Source Circuit Circuit Type Circuit Abbr Wiring Style Symbol Type Description Gauge Color 6700/5496 NAC Notification V Class B Fire Alarm 14/2 SOL JKT FPLP 1M RL RED #14 Red 6700 SLC Signaling line U Class B Fire Alarm 1812 SOL JKT FPLR 1 M RL RED #18 Black 6700 IDC Initiating Z Class B Fire Alarm 1812 SOL JKT FPLR 1 M RL RED #18 Red 6700 SBUS Power/Serial P Class B Fire Alarm 18/4 SOL JKT FPLR 1M RL RED #18 Red N N N N O O N N O O N (N O W a /2\ FLAG NOTES 1� CONTRACTOR WILL PROVIDE SURGE PROTECTION FOR ALL WIRING TO DEVICES THAT ARE LOCATED ON EXTERIOR/OUTSIDE WALLS. 2� VERIFY WITH AHJ EXACT LOCATION OF OUTSIDE HORN STROBE. PROVIDE WEATHERPROOF ENCLOSURE FOR EXTERIOR DEVICES, TYPICAL. ® VERIFY ALL LOCATIONS OF MODULES FOR SPRINKLER RISER SYSTEM. SHOULD DEVICE COUNT CHANGE ADD LOCATION AND ADDRESSES ON AS -BUILT DRAWINGS. VERIFY ON -SITE CONDITIONS FOR EXTERIOR COMMUNICATOR ANTENNA IF NEEDED. C PROVIDE RED PLASTIC PULL STATION SIGN WITH 1" HIGH WHITE ENGRAVED LETTERS AND MOUNTED ABOVE PULL STATION. SIGN SHALL SAY THE FOLLOWING: "IT IS THE RESPONSIBILITY OF ANYONE PLACING THIS FIRE ALARM SYSTEM INTO TEST TO INFORM THE MONITORING STATION TO NOT PLACE THE FACP PULL STATION INTO TEST. THIS POINT MUST STAY ACTIVE." WA L&I - IF SPRINKLER IS PRESENT. PROVIDE HEAT (5621 Fixed & ROR) DETECTOR AT BOTTOM OF SHAFT FOR SECONDARY LEVEL RECALL AND FLASH HAT (FLASHING) ACTIVATION. INSTALL w/IN 24" SPRINKLER. ® DEDICATED CIRCUIT BREAKER FOR FIRE ALARM SYSTEM PROVIDED BY OTHERS & LOCATED IN ELECTRICAL ROOM STROBE ONLY DUE TO VICINITY OF RATH TWO-WAY COMMUNICATION STATION. FAN SHUTDOWN RELAYS PROVIDED FOR BAF CE-2, CE-3, AND CE-4 FANS. COORDINATE RELAY LOCATION WITH EACH CONTROLLER, FINAL CONNECTIONS BY OTHERS. FIRE RISER 112 SLC RETURN T MD 97S•M:010, 011 LOW TEMP SWITCH; SPARE SLC SEND 4 MD 97S•M :008 009 DCVA ISO VLV, 97S•S:001 S SYS CTRL VLV c MD M BYPASS F�06C E K VALVE; PIV VALVE MD M 00S 005 WES IS04� WET SYS FLW SWTCH M D 97S•M:002, 003 TWO WAY AC LOSS; TWO WAY COMM LOSS F NAC F FROM LEVEL 2 M:001 MECHANICAL RM 97S-M:012 BAF CF-2 RM 97S•M:013 BAF CF-3 RM 97S•M:014 BAF CF-4 ROOM ill CABLE/CIRCUITING SCHEDULE CABLE TYPES: SILENT KNIGHT 6700 Source Circuit Circuit Type Circuit Abbr Wiring Style Symbol Type Description Gauge Color 6700/5496 NAC Notification V Class B Fire Alarm 14/2 SOL JKT FPLP 1 M RL RED #14 Red 6700 SLC Signaling line U Class B Fire Alarm 18/2 SOL JKT FPLR 1 M RL RED #18 Black 6700 IDC Initiating Z Class B Fire Alarm 18/2 SOL JKT FPLR 1M RL RED #18 Red 6700 SBUS Power/Serial P Class B Fire Alarm 18/4 SOL JKT FPLR 1M RL RED #18 Red EE FLOOR PLAN SEE FLOOR PLAN FOR CONTINUATION ELEVATOR MACHINE ROOM 97S•S:002 ELEVATOR ROOM SMOKE DETECTOR 97S•M:015, 016, 017, 018 DR SECONDARY ELEVATOR RECALL ELEVATOR FLASH HAT 97S•M:019, 020, 021, 022 DR PRIMARY ELEVATOR RECALL ELEVATOR ALTERNATE FLASH HAT MD H• 2 EATOR SHU 0RIP I R ELEVATOR POWER LOSS UP 1 RISER ROOM AND MECHANICAL ROOM DETAILS N FA.1.01 FA.1.03 SCALE: 1 /2" = V-0" 0 0 5 10 15 20 W FMM 97S•M:025 ELEVATOR MACH. ISO VLV 2 ELEVATOR MACHINE ROOM DETAILS FA.1.01 FA.1.03 SCALE: 1 /2" = 1 '-O" 0 5 10 15 20 �EEIFLOIOR READ OR CONTINUATI `I z U) O z U 0 U) w Cn ry z J O Q U 2 10� U) O ry LL Q w D W C Ln LL. v J W U_ z � o L) 0 J � 2 J W � z O Ln J J W (/) m z O a U V) w Ln (V C~/)COOO W 61 Ln F--- < 1-- �2rn� , < r,, D Z = O O �VQ0QD Z M M lD J a-; L4--: J W m F I R2022-0110 RESUB Nov 29 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ' REVIEWED BY: C. RUSSELL ' NICET LEVEL III CERT NO. 120520 07 Z C� J 0 0 Z w O � 2i J 0 w W v) LL O O O w � z O 0 < o LU Q o0 0 U) a' > J Q w U)Q w J z _ z U 0 CC C) o Q Q < G 0 2 0 Z c) w Q° Q O N w LL w z p LL.I u u w w O IW w � cn N LL 0- LUof DRAWING SIZE: E SIZE 130"x42" DRAWN BY: J. LUCHSINGER ' DATE DRAWN: 10/07/2022 ' 1 REV DATE: 11/28/2022 REV 2 BUSINESS LICENSE # SECURSN790NE ELECTRICAL LICENSE # SECURSN954JG FA. 1.02 N N O N O N r N N O N 00 N W a , r E D 'a:�C B ��i �� _ � A .� 2 1 w Rc r_ 44_"�& 1 I A T.0_F. Hj_&I I 47-!Y" — —�_ ____— _ •_ _ _ _ = __� _ l==�_ _ —rl- _ 41' i"_ immommmil imi 6mmmi� 6m6 m 1, -.a KIM ;III_& 1 ROOF T I EIII' IE EQUPPMENT 1 _, I I 4 371 _ 411 OFFICE a ROOM AR OF PLATFORM titi r 20ED9 1 I j l Ij i a — — — 02 — — 1— — — — — — — — — — — — — — — — — — — — — — — I — — — — E .0. TLIT. L 27' . 2 1 ?� a b I I I DOUBLE HT. 1 I r I I COMMERCIAL MAINTENANCE � fRET I. I MEEH, I r'•• I I 1 �� � 111 I � 1 �� � I I jai PIT DEPTH - - - - - - - - - - - - - - - - - - -' - - - - - - - - - - - - - 1D,_ HH SECTION FOR INFORMATION ONLY SCALE: NONE .d .11111 WEST ELEVATION via' = 1'.0. _ SOLAR PAN EL 47'_0" ] C7 0 3 _ MAX. O L CMG . I••�IT. 44' _ n�- T .Q. Fes- H 43' . 9" T, 0Y (L 41 ' - 6" W- " B O. STIRUCT. ROOF 3 r7' - 4' LEVEL 0 91 _oil -d — 27' - 2 1 r2m .. _LEVEL U1 1 _& 4' _ 0 z 0 F_ U F_ z O U Of O LL w D U) L z O Lu J Q U) Q W Of LL Na �C/) W LL zU) oL) L) 0 5J G J � WCD z J J W m z O d U w 0 I (V OO Lu Lr) QQ��I .Q�� V Q0 Q0 z M M J 4-; L4-: J W m F I R2022-0110 RESUB Nov 29 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ' REVIEWED BY: C. RUSSELL ' NICET LEVEL III CERT NO. 120520 0 z OC G 0 Lu LL O O 0- 2i w U) C/) LL Q w a Q w w LL O CV z Q 00 O U J Q U) Q � 0 z o z a 0 o P: U) z p z O °Q Z p N� 0 Q w W W O Lu O J Lu DRAWING SIZE: E SIZE 30"x42" DRAWN BY: J. LUCHSINGER DATE DRAWN: 10/07/2022 REV DATE: 11/28/2022 REV 2 BUSINESS LICENSE # SECURSN790NE ELEVATION FOR INFORMATION ONLY SCALE: NONE ELECTRICAL LICENSE # SECURSN954JG FA. 1.04 N N N N O O N N O O N N O W a 4\ FLAG NOTES J> CONTRACTOR WILL PROVIDE SURGE PROTECTION FOR ALL WIRING TO DEVICES THAT ARE LOCATED ON EXTERIOR/OUTSIDE WALLS. VERIFY WITH AHJ EXACT LOCATION OF OUTSIDE HORN STROBE. PROVIDE WEATHERPROOF ENCLOSURE FOR EXTERIOR DEVICES, TYPICAL. ® VERIFY ALL LOCATIONS OF MODULES FOR SPRINKLER RISER SYSTEM. SHOULD DEVICE COUNT CHANGE ADD LOCATION AND ADDRESSES ON AS -BUILT DRAWINGS. VERIFY ON -SITE CONDITIONS FOR EXTERIOR COMMUNICATOR ANTENNA IF NEEDED. © PROVIDE RED PLASTIC PULL STATION SIGN WITH 1" HIGH WHITE ENGRAVED LETTERS AND MOUNTED ABOVE PULL STATION. SIGN SHALL SAY THE FOLLOWING: "IT IS THE RESPONSIBILITY OF ANYONE PLACING THIS FIRE ALARM SYSTEM INTO TEST TO INFORM THE MONITORING STATION TO NOT PLACE THE FACP PULL STATION INTO TEST. THIS POINT MUST STAY ACTIVE." WA L&I - IF SPRINKLER IS PRESENT. PROVIDE HEAT (5621 Fixed & ROR) DETECTOR AT BOTTOM OF SHAFT FOR SECONDARY LEVEL RECALL AND FLASH HAT (FLASHING) ACTIVATION. INSTALL WIN 24" SPRINKLER. ® DEDICATED CIRCUIT BREAKER FOR FIRE ALARM SYSTEM PROVIDED BY OTHERS & LOCATED IN ELECTRICAL ROOM STROBE ONLY DUE TO VICINITY OF RATH TWO-WAY COMMUNICATION STATION. FAN SHUTDOWN RELAYS PROVIDED FOR BAF CE-2, CE-3, AND CE-4 FANS. COORDINATE RELAY LOCATION WITH EACH CONTROLLER, FINAL CONNECTIONS BY OTHERS. 15CD 15CD 15CD 15CD 15CD 15CD 75CD 75CD 15CD 15CD 30CD 15CD 15CD 15CD O H - H v� H H H H ��-iJ H Q`i.r i' IS, O O O O O°O O°O O° C9 C9 C9 C9 ` C9 0 C9 ` f9 : Qry Qry Qry Qry Qry Qry Qry Qry Qry Qry Qry Qry Qry Qry 75CD 75CD 75CD 75CD 75CD 15CD 15CD 15CD 30CD 30CD 30CD �H 1 H - ICI' o°^ ICI H -H H Qry. Qry. 5 Qry. h Qry. Qry. Qry. Qry. Qry. Qry. Qn,. Qry. CABLE/CIRCUITING SCHEDULE CABLE TYPES: SILENT KNIGHT 6700 Source Circuit Circuit Type Circuit Abbr Wiring Style Symbol Type Description Gauge Color 6700/5496 NAC Notification V Class B Fire Alarm 14/2 SOL JKT FPLP 1M RL RED #14 Red 6700 SLC Signaling line U Class B Fire Alarm 18/2 SOL JKT FPLR 1 M RL RED #18 Black 6700 IDC Initiating Z Class B Fire Alarm 18/2 SOL JKT FPLR 1 M RL RED #18 Red 6700 SBUS Power/Serial P Class B Fire Alarm 18/4 SOL JKT FPLR 1 M RL RED #18 Red 15CD EXTERIOR HORN STROBE LOCATION TO BE APPROVED BY AHJ. VERIFY MOUNTING LOCATION ON ASBUILT DWGS. 110CD WP ANNUCIATOR 5860G 110 VAC (TYP) NEUTRAL (TYP) GROUND (TYP) 1412 P2:SIG1 NOTIF 1 P1:SIG1 NOTIF(V) 14/2 SBUS (P) FACP SBUS (P) 18/4 18/a SILENT KNIGHT 5496 P2 ,SBP1.01 110 VAC (TYP) NEUTRAL (TYP) GROUND (TYP) 97S•S:004 97S•S:005 97S•M:028 ELEVATOR TOP OF ELEVATOR LOBBY ELEVATOR SHAFT ISO VALVE 135°F/RR 97S•S:003 97S•M:026 97S•M:027 ELEVATOR ELEVATOR ELEVATOR LOBBY PIT PIT ISO VALVE 1. 1350E 97S•M:029 TOP OF ELEVATOR PROVIDE SMOKE AND HEAT (SYSTEM SENSOR 5623 FIXED WITH RELAY) DETECTOR AT THE TOP OF SHAFT FOR ELEVATOR RECALL AND SHUNT TRIP ACTIVATION, IF SPRINKLER IS PRESENT. PROVIDE SMOKE DETECTOR FOR ELEVATOR RECALL IF SMOKE RELIEF EQUIPMENT IS PRESENT. INSTALL HEAT DETECTOR WITHIN 24" OF SPRINKLER HEAD IF PRESENT. 97S•M:012 97S•M:013 97S•M:014 97S•S:002 97S•M:015, 016, 017, 018 97S•M:019, 020, 021, 022 BIG ASS FAN BIG ASS FAN BIG ASS FAN ELEVATOR ROOM SECONDARY ELEVATOR PRIMARY ELEVATOR RECALL CF-2 CF-3 CF-4 SMOKE DETECTOR RECALL ELEVATOR FLASH HAT ELEVATOR ALTERNATE FLASH HAT MECHANICAL ROOM 111 ELEVATOR MACHINE ROOM 107 I-VLV VLV I-VLV SLC ISOLATION RETURN VLV PIV VLV (LOCATED IN ELECTRIAL ROOM) 97S•S:001 97S•M:001 ELECTRICAL ELECTRICAL ROOM ROOM 18/2 SLC 1(U) CLASS A SLC ISOLATION SEND (LOCATED IN ELECTRIAL ROOM) 97S•M:023,024 97S•M:025 HEAT FOR SHUNT TRIP ELEVATOR MACHINE ELEVATOR POWER LOSS ISO VALVE 97S•M:002, 003 97S•M:004, 005 97S•M:006, 007 97S•M:008, 009 97S•M:010, 011 TWO WAY AC LOSS WET SYS ISO VLV BYPASS FDC CHECK VALVE DCVA ISO VLV LOW TEMP SWITCH TWO WAY COMM LOSS WET SYS FLW SWTCH PIV VALVE SYS CTRL VLV SPARE FIRE RISER ROOM 112 FACP [�> RADIO SILENT TEL#1 TWO-WAY KNIGHT TEL42 COMMUNICATOR 6700 AES 7707P P1 110 VAC (TYP) 110 VAC (TYP) NEUTRAL (TYP) NEUTRAL (TYP) GROUND (TYP) GROUND (TYP) RISER DIAGRAM CLASS W SCALE: NONE LEVEL 2 LEVEL 1 z U) O z O U U) ry w Cn Ir z J O Q U 2 D_ U) O ry ILLQ w W Cn 07 LL. W LL zU) o L) 0 J U� J W � z CD Ln J J W (/) Im z O a U V) w Lf1 (V C~/)0000 LU CY) L�r) QQj- CT) ,Ql�tfl Z = O O U Q0 Q0 z M M L4-: J LU co F I R2022-0110 RESUB Nov 29 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ' REVIEWED BY: C. RUSSELL ' NICET LEVEL III CERT NO. 120520 () M z O 2i M LU LL O N� O 0— O o Q LU Q 00 �/� Cy)�� V VJ J > J Q Q U z 0 L z Q C) O Q 2 C) 0 z Q LLI Q O N LL.zLU Q p L1J o W W W ��^^ W N 0 O V JJ N L.L LU DRAWING SIZE: E SIZE 130"x42" DRAWN BY: J. LUCHSINGER ' DATE DRAWN: 10/07/2022 ' 1 REV DATE: 11/28/2022 REV 2 BUSINESS LICENSE # SECURSN790NE ELECTRICAL LICENSE # SECURSN954JG FA.2.01 N N 0 0 04 N w O 0 N N Q O � � 0 z W O z o U U) � w z J ° = z o o Of w W U U) � w cn U_ p N � w z O r", C.i N 0 c~i� co O O --� LU M n QQ�� Q M J a Uz=oo W z �IJ .Mrn 0 J CD J UlJ J W W F I R2022-0110 RESUB Nov 29 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVIEWED BY: C. RUSSELL NICET LEVEL III CERT NO. 120520 C/) 0 Z O 0 W U) LL Z O � _j O i) 0 J W Q CD 00 0 C� � � Q > w Q U) �n QLU z z °-° - ° �w Q 0 a = w � o p Z LL_O LU N Cn z J w u u W w w O W Z PANEL SCHEDULES AND CALCULATIONS DRAWING SIZE: E SIZE 30"x42" SCALE: NONE DRAWN BY: J. LUCHSINGER DATE DRAWN: 10/07/2022 REV DATE: 11/28/2022 REV 2 BUSINESS LICENSE # SECURSN790NE ELECTRICAL LICENSE # SECURSN954JG FA.3.01 Battery Calculations for Panel: 6700 Part No: 6700 - INTELLIKNIGHT, FACP, 2 PROGRAMMABLE OUTPUTS PART N0. 6700 B QTY DESCRIPTION Panel Equipment MAIN CARD STANDBY CURRENT (AMPS) 0.165000 TOTAL STANDBY CURRENT (AMPS) ALARM CURRENT (AMPS) 0.310000 TOTAL ALARM CURRENT (gMPS) 0.310000 1 0.165000 Total Panel Stby 0.165000 Total Panel Alarm 0.310000 Peripheral Devices P2RK 1 HORN/STROBE, 2 WIRE, M-C, RED, OUTDOOR (Notification) 0.00000 0.00000 0.21200 0.21200 SK-RELAY 3 RELAY MODULE, ADDRESSABLE (Signaling line) 0.00026 0.00077 0.00026 0.00077 SK-RELAYMON2 2 RELAY MODULE, ADDRESSABLE (Signaling line) 0.00135 0.00270 0.02400 0.04800 5860G 1 REMOTE LCD ANNUNCIATOR, RED (Power) INTELLIGENT PWR EXPANDER, 6-AMP, 4-NAC, 5496 MB (Power) 0.02000 0.02000 0.02500 0.02500 5496 1 0.01000 0.01000 0.01000 0.01000 SK-ISO 2 ISOLATION MODULE (Signaling line) 0.00045 0.00090 0.00500 0.01000 SK-PHOTO-W 5 SMOKE, PHOTOELECTRIC, ADDRESSABLE. WHITE DUAL MONITOR MODULE (Signaling line) 0.00020 0.00100 0.00450 0.02250 SK-MONITOR 2 6 0.00075 0.00450 0.00075 0.00450 SK-MONITOR 5 INTERFACE MODULE, ADDRESSABLE (Signaling line) 0.00038 0.00190 0.00038 0.00190 SK-PULL-SA 1 PULL STATION, SINGLE ACTION, ADDRESSABLE (Signaling line) 0.00038 0.00038 0.00038 0.00038 Total Periph Stby 0.041105 Total Periph Alarm 0.33505 Total Standby Amps 0.206105 Total Alarm Amps 0.645050 STANDBY: 24 Hrs 4.947 AH ALARM TIME: 5 Min 0.054 AH BATTERY REQUIREMENTS 5.001 AH Compensation Factors - Standby: 1.2 Alarm 1.2 REQUIREMENT WITH COMPENSATION 20% 6.0012 AH Circuit Calculations Panel: P1 Card: 00 Circuit:97S Circuit Name: 97S Circuit Type: Signaling line/SK - SLC Terminal Voltage: 20.4 V:DC Amperage: 3.0000 A Cable: 18/2 SOL JKT FPLR 1 M RL RED #18 Calculations based on Running Total Length. Return Path Design Criteria: Ambient temperature: 167 °F Minimum operating voltage: 16.88 V Device Part No Appliance Desc Distance Current Volta a Voltage Drop 6700 Panel 20.4 V M:029 SK-MONITOR INTERFACE MODULE, ADDRESSABLE 35'-0 0.3750 mA 20.3945 V (0.0055 V) S:005 SK-PHOTO-W LOW -PROFILE PHOTOELECTRIC SENSOR WHITE 10'-0 0.2000 mA 20.393 V (0.0015 V) M:028 SK-MONITOR INTERFACE MODULE, ADDRESSABLE 35'-0 0.3750 mA 20.3855 V (0.0051 V) S:004 SK-PHOTO-W LOW -PROFILE PHOTOELECTRIC SENSOR WHITE 16'-0 0.2000 mA 20.3906 V (0.0024 V) M:027 SK-MONITOR INTERFACE MODULE, ADDRESSABLE 5'-0 0.3750 mA 20.3855 V (0.0051 V) M:026 SK-MONITOR INTERFACE MODULE, ADDRESSABLE 35'-0 0.3750 mA 20.3855 V (0.0051 V) S:003 SK-PHOTO-W LOW -PROFILE PHOTOELECTRIC SENSOR WHITE 14'-0 0.2000 mA 20.3836 V (0.0019 V) M:025 SK-MONITOR INTERFACE MODULE, ADDRESSABLE 56'-0 0.3750 mA 20.3855 V (0.0051 V) M:023, 024 SK-MONITOR 2 DUAL MONITOR MODULE 10'-0 0.7500 mA 20.376 V (0.0076 V) M:019, 020, 021, 022 K-RELAYMON-2 2 DUAL MONITOR, 2 RELAY OUTPUT 10'-0 1.3500 mA 20.3747 V (0.0012 V) M:015, 016, 017, 018 K-RELAYMON-2 2 DUAL MONITOR, 2 RELAY OUTPUT 6'-0 1.3500 mA 20.3741 V (0.0006 V) S:002 SK-PHOTO-W LOW -PROFILE PHOTOELECTRIC SENSOR WHITE 5'-0 0.2000 mA 20.3737 V (0.0004 V) M:014 SK-RELAY RELAY MODULE, ADDRESSABLE 60'-0 0.2600 mA 20.3689 V (0.0048 V) M:013 SK-RELAY RELAY MODULE, ADDRESSABLE 5'-0 0.2600 mA 20.3686 V (0.0004 V) M:012 SK-RELAY RELAY MODULE, ADDRESSABLE 4'-0 0.2600 mA 20.3683 V (0.0003 V) M:010, 011 SK-MONITOR 2 DUAL MONITOR MODULE 62'-0 0.7500 mA 20.3641 V (0.0042 V) M:008, 009 SK-MONITOR 2 DUAL MONITOR MODULE 4'-0 0.7500 mA 20.3639 V (0.0002 V) M:006, 007 SK-MONITOR 2 DUAL MONITOR MODULE 3'-0 0.7500 mA 20.3638 V (0.0001 V) M:004, 005 SK-MONITOR 2 DUAL MONITOR MODULE 4'-0 0.7500 mA 20.3636 V (0.0001 V) M:002, 003 SK-MONITOR 2 DUAL MONITOR MODULE 6'-0 0.7500 mA 20.3635 V (0.0001 V) M:001 SK-PULL-SA PULL STATION, SINGLE ACTION, ADDRESSABLE 102'-0 0.3750 mA 20.3626 V (0.0009 V) S:001 SK-PHOTO-W LOW -PROFILE PHOTOELECTRIC SENSOR WHITE 4'-0 0.2000 mA 20.3626 V (0 V) 441'-0 10.1050 mA Total Current: 10.1200 mA (Total VDrop Percent: 0.18%) Total Voltage Drop: 0.0374 V � Circuit Calculations Panel: P1 Card: 00 Circuit:SIG1 Circuit Name: SIG1 Circuit Type: Notification Terminal Voltage: 20.4 V:DC Amperage: 3.0000 A Cable: 14/2 SOL JKT FPLR 1 M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167 °F Minimum operating voltage: 16.88 V Device Part No Appliance Desc Panel Distance Current Voltage Voltage Drop 6700 20.4 V 001 SRK STROBE, 2 WIRE, STANDARD CD, RED, OUTDOOR, 110CD 56'-0 202.0000 mA 20.331 V (0.0695 V) 56'-0 202.0000 mA Total Current: 202.0000 mA (Total VDrop Percent:0.34%) Total Voltage Drop: 0.0695 V Battery Calculations for Panel: P2 Part No:5496 -INTELLIGENT PWR EXPANDER, 6-AMP, 4-NAC Part No. Qt Description Standby Total Standby Alarm Total Alarm Panel Equipment 5496 MB 1 INTELLIGENT POWER MODULE MAIN BOARD 40.0000 mA Total Panel Stby 40.0000 mA 160.0000 mA 160.0000 mA 160.0000 mA Peripheral Devices L-SERIES STROBE, WHITE, WALL (Notification) 15CD L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL (Notification) 75CD 89dB 40.0000 mA Total Panel Alarm SWL 6 0.0000 mA 0.0000 mA 43.0000 mA 258.0000 mA P2WL 5 0.0000 mA 0.0000 mA 121.0000 mA 605.0000 mA PC2WL 4 L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING (Notification) 15CD 89dB 0.0000 mA 0.0000 mA 71.0000 mA 284.0000 mA PC2WL 4 L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING (Notification) 30CD 89dB 0.0000 mA 0.0000 mA 90.0000 mA 360.0000 mA P2WL 5 L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL (Notification) 15CD 89dB 0.0000 mA 0.0000 mA 54.0000 mA 270.0000 mA P2WL 2 L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL (Notification) 30CD 89dB 0.0000 mA 0.0000 mA 74.0000 mA 148.0000 mA Total Peripheral Stby 0.0000 mA Total Periph Alarm 1925.0000 mA Total Standby Amps 40.0000 mA Total Alarm Amps 2085.0000 mA Standby time: 24 Hrs 0.96 Ah Alarm time: 5 Min 0.174 Ah Battery requirement: 1.134 Ah Compensation Factors -Standby: 1.2 Alarm: 1.2 Requirement with compensation: 1.361 Ah Circuit Calculations Panel: P2 Card: 6 Circuit:SIG1 Circuit Name: SIG1 Circuit Type: Notification Terminal Voltage: 20.4 V:DC Amperage: 2.0000 A Cable: 14/2 SOL JKT FPLR 1 M RL RED #14 Calculations based on Running Total Length. Return Path Design Criteria: Ambient temperature: 167 °F Minimum operating voltage: 16.88 V Device Part No Appliance Desc Distance Current Voltage Voltage Drop 5496 Panel 20.4 V 012 P2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 75CD 56'-0 121.0000 mA 20.0304 V (0.3696 V) 011 010 P2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 75CD L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 75CD 29'-0 43'-0 121.0000 mA 121.0000 mA 19.8605 V 19.6406 V (0.1699 V) (0.2199 V) P2WL 009 P2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 75CD 27'-0 121.0000 mA 19.5225 V (0.118 V) 008 SWL L-SERIES STROBE, WHITE, WALL, 15CD 33'-0 43.0000 mA 19.4028 V (0.1197 V) 007 SWL L-SERIES STROBE, WHITE, WALL, 15CD L-SERIES STROBE, WHITE, WALL, 15CD 11'-0 43.0000 mA 19.3658 V (0.037 V) 006 SWL 23'-0 43.0000 mA 19.2945 V (0.0713 V) 005 PC2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING, 30C 19'-0 90.0000 mA 19.2406 V (0.0539 V) 004 PC2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING, 30C 32'-0 90.0000 mA 19.1675 V (0.0731 V) 003 PC2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING, 30C 24'-0 90.0000 mA 19.1259 V (0.0416 V) 002 PC2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING, 15C 27'-0 71.0000 mA 19.0941 V (0.0318 V) 001 P2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 75CD 35'-0 121.0000 mA 19.0681 V (0.026 V) 359'-0 075.0000 mA Total Current: 1075.0000 mA (Total VDrop Percent:6.53%) Total Voltage Drop: 1.3319 V Circuit Calculations Panel: P2 Card: 6 Circuit:SIG3 Circuit Name: SIG3 Circuit Type: Notification Terminal Voltage: 20.4 V:DC Amperage: 2.0000 A Cable: 14/2 SOL JKT FPLR 1 M RL RED #14 Calculations based on Running Total Length. Return Path Design Criteria: Ambient temperature: 167 °F Minimum operating voltage: 16.88 V Device Part No Appliance Desc Distance Current Volta a Voltage Drop 5496 Panel 20.4 V 015 SWL L-SERIES STROBE, WHITE, WALL, 15CD 45'-0 43.0000 mA 20.107 V (0.293 V) 014 P2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 15CD 10'-0 54.0000 mA 20.044 V (0.063 V) 013 SWL L-SERIES STROBE, WHITE, WALL, 15CD 9'-0 43.0000 mA 19.991 V (0.053 V) 012 PC2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING, 15CD 16'-0 71.0000 mA 19.900 V (0.091 V) 011 PC2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING, 15CD 55'-0 71.0000 mA 19.613 V (0.287 V) 010 PC2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING, 15CD 21'-0 71.0000 mA 19.512 V (0.101 V) 009 P2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 30CD 17'-0 74.0000 mA 19.438 V (0.074 V) 008 P2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 30CD L-SERIES STROBE, WHITE, WALL, 15CD HORN/STROBE, 2 WIRE, STANDARD CD, RED, OUTDOOR, 110CD 31'-0 74.0000 mA 19.317 V (0.121 V) 007 SWL 30'-0 43.0000 mA 19.214 V (0.103 V) 006 P2RK 20'-0 212.0000 mA 19.150 V (0.064 V) 005 PC2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING, 30CD 19'-0 90.0000 mA 19.115 V (0.036 V) 004 P2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 15CD 33'-0 54.0000 mA 19.071 V (0.044 V) 003 P2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 15CD 32'-0 54.0000 mA 19.039 V (0.032 V) 002 P2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 15CD 27'-0 54.0000 mA 19.021 V (0.018 V) 001 P2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 15CD 29'-0 54.0000 mA 19.012 V (0.010 V) 394'-0 1062.000 mA Total Current: 1062.0000 mA (Total VDrop Percent:6.81 %) Total Voltage Drop: 1.3885 V N N O N O N r W a ANNUNCIATOR 5860 5 SCALE: NTS BUI'"'"' STF NEMA ENCLI SIZE f COAXIA TO TRAN; FINISHED GRADE CONNECT GROUNDING CABLE TO ELECTRICAL COUNTERPOISE WHERE AVAILABLE ANTENNA SEAL ANTENNA MAST ANTENNA MOUNTING BRACKET NEMA 3R ENCLOSURE, SIZE PER NEC WITH LIGHTING ARRESTOR FOR COAX CABLE C�0 _ . 146 BARE COPPER (BC) GROUNDING ELECTRODE CONDUCTOR, TINNED IN 5/8" PVC EXOTHERMIC WELD GROUND ROD: 3/4" DIAMETER X 10 FEET LONG COPPER CLAD COMMUNICATOR ANTENNA (IF USED 2 SCALE:NTS ALWAYS BREAK A WIRE BEFORE CONNECTING IT TO A FIRE ALARM DEVICE, NEVER LOOP AN UNBROKEN WIRE UNDER ANY TERMINAL. CORRECT INCORRECT CONNECT ONLY TWO WIRES UNDER EACH WIRE NUT OR TERMINAL. CORRECT INCORRECT CORRECT (INCORRECT' WIRING METHODS 4 SCALE: NTS NOMINAL 1/4" THICK INTUMESCE ELECTROMETRIC MATERIAL FAC ON SIDE WITH ALUMINUM FOIL IN WIDE STRIPS FOR EXPOSED ARE) SYSTEM NO. W-L-1001 FIRESTOPPING CONFIG. "A" FIRE RATED WALL CONDUIT, SEE PLANS FOR SIZE AND LOCATION. CAULKING, SEE NOTE #2 BELOW FOR CONCEALED AREAS. ONE AND TWO HOUR RATED WALLS nl()T�Q- 1. ENTIRE ASSEMBLY TO BE U.L. APPROVED. REFER TO U.L. BUILDING MATERIALS DIRECTORY SYSTEM NO. W-L-1001 CONFIGURATION "A" FOR ADDITIONAL INFORMATION. 2. CAULK FILL MATERIAL FORCED INTO ANNULAR SPACE TO MAXIMUM 3/16" IN. AND WITH A MINIMUM 1/4" IN. DIAMETER CONTINUOUS BEAD OF CAULK APPLIED TO THE DIAMETER OF CONDUIT AT ITS EGRESS FROM THE WALL. MANUFACTURER "MINNESOTA MINING AND MANUFACTURING CO."- TYPE CP-25 S/L, CP-25 N/S. LRATED WALL FIRE STOP DETAIL 3 SCALE: NTS 7707P-88 FRONT VIEW AES 7707P COMMUNICATOR SCALE: NTS AES 7707P COMMUNICATOR, 5860G ANNUNCIATOR, AND DETAILS SCALE: NONE z 0 U H z 0 U Of 0 LL w D cn z 0 U) w ry J Q U) Q W Of m C/) w U- z � O L) 0 J � 2 J � w z CD J J W C� Ga z O U w 0 (V C~/)000O W 61 CY) Ln QQzj- CT) ,Q�tfl Z = O O V z M M lD J a--, L4-: J w m F I R2022-0110 RESUB Nov 29 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVIEWED BY: C. RUSSELL NICET LEVEL III CERT NO. 120520 1 U) Q C%) o 0 p z z O Q 2i ck 0 O LU Q L.L z O z � Q 0 o O (.0 V oo C Ln W Q 0000 0 Cy)O U) Q U) Q z z z 2E O o < <O � �p z u� w < ° w z Q 0 o O Lij u u � Ll 0- w a Q DRAWING SIZE: E SIZE 130"x42" DRAWN BY: J. LUCHSINGER DATE DRAWN: 10/07/2022 REV DATE: 11/28/2022 REV 2 BUSINESS LICENSE # SECURSN790NE ELECTRICAL LICENSE # SECURSN954JG FA.4.01 FROM FACP OR PREVIOUS SLC DEVICE 61 O o Q O ADDRESSABLE SLC LOOP T11 Ext PWR(-) SLEDS CABLE, Ti T10 Ext PWR(+) SLC (-) T1 T9 SUP A (+) SLC (+) T2 T8 SUP A (-) T7 SUP AB (-) T6SUP AB 31((%�11)3: zg3�y Il TENS ONES TO NEXT SMODUE �TlOL SLC DEVICE SK-CONTROL MODULE 9 SCALE: NTS NOTES: -`CLASS B' WIRING SHOWN - REFER TO INSTALLATION INSTRUCTIONS FOR RELAY CONTACT RATINGS FROM FACP OR PREVIOUSO SLC DEVICE ADDRESSABLE SLC LOOP CABLE, TYP. 1- 2+ 3 4 04 'O TENS # ONES LED SILENT KNIGHT SK-PULL-SA MANUAL PULL STATION �I. TO NEXT SLC DEVICE SK-PULL-SA MANUAL PULL STATION �)NSCALE:NTS OTES: -'CLASS B' WIRING SHOWN 4" MIN TO ADJACENT WALL i/T 4" MIN TO TOP CEILING -MOUNTED OF DET TO CEILING/ HEAT DETECTOR 12" MAX WALL -MOUNTED HEAT DETECTOR A/C SUPPLY OR RETURN DIFFUSER CEILING " AUDIBLE/VISUAL � 60"MIN AND/OR VISUAL 6"MIN. ONLY APPLIANCE AUDIBLE -ONLY 1-7�❑- APPLIANCES 80"-96" TO 90" MIN. WHERE LOWEST PART CEILING HEIGHT OF LENS ALLOWS O 5' MAX MANUAL F7r1 PULL STATION 48" SNAP ON REMOTE D CCJORATIVE ANNUNCIATOR CAUTION: DO NOT LOOP WIRE UNDER + i — TERMINAL 1 OR 2. BREAK WIRE RUN TO PROVIDE SUPERVISION OF CONNECTIONS. Q`—SCREWS (NOT SUPPLIED) J LU O O �m o 0 o zQ 0- 0 0 L- - 3 1 J e 3 3 rw o m o o m o o m o O J (-) 0 — — — — — ----/----J H — — — — — CLASS A OPTIONAL WIRING— — 6" DETECTOR BASE WIRING DETAIL L� SCALE: NTS O O ® T9 ® T8 NOT USED ® T7 ® T6 ® TS O O 0 00 O SLEDS SLC IN (-) T1 SLC IN (+) T2 SLC OUT (-) T3 SLC OUT (+) T4 FROM FACP OR PREVIOUS SLC DEVICE SK-ISO O O MODULE O TO FIRST OR NEXT SLC DEVICE SK-ISO MODULE 8 SCALE: NTS -'CLASS A' WIRING SHOWN NOTES: - A MAXIMUM OF 25 DEVICES CAN BE USED BETWEEN ISOLATORS. ADDRESSABLE SLC LOOP CABLE, TYP. FROM FACP OR PREVIOUS NAC DEVICE C 0 C E.O.L.D. SYSTEM SENSOR P2'X'L/PC2'X'L L-SERIES HORN/STROBE 0MOPLA �C dC CY ADDRESSABLE SLC LOOP CABLE, TYP. TO NEXT NAC DEVICE E.O.L.D. TO BE PLACED ON LAST DEVICE OF RESPECTIVE NAC CIRCUIT. S'X'L/SC'X'L L-SERIES STROBE SCALE: NTS NOTES: -'CLASS B' WIRING SHOWN -'X' DENOTES COLOR: R = RED W = WHITE S SEE NOTES FOR EXTERIOR SPEAKER / STROBE MOUNTING NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST CEILING POINT OF DETECTOR CEILING MOUNTED SMOKE/HEAT DETECTOR MOUNT FMCP TOP AT 72" OR 60" TO CENTERLINE WHICHEVER IS LOWER 72" 60" DEVICE MOUNTING ELEVATION REQUIREMENTS 13 ' SCALE: NTS -_O FROM FACP OR PREVIOUS SLC DEVICE O O O O 0 STATDUS LE SLC (-) T1 T9 SUP A (+) SLC (+) T2 EOL 01 T8SUP A(-) + T7 SUP DETECTOR EOL L1 T6 SUP BASE 3z013 yCrCj) M (NOT TENS ONES TO NEXT UPPLIED) O O SK MONITOER 2 O O SLC DEVICE ADDRESSABLE SLC LOOP CABLE, TYP. SK-MONITOR-2 (DUAL MONITOR MODULE SCALE: NTS -'CLASS B' WIRING SHOWN NOTES: ADDRESSABLE SLC LOOP CABLE, TYP. FROM FACP OR PREVIOUS SLC DEVICE OTO NEXT SLC DEVICE WALL -MOUNTED SMOKE DETECTOR 10' CEILING STROBE OR HORNSTROBE/SPEAKER FINISHED WALL FINISHED FLOOR O O O O 0 STEEDS SLC (-) Ti 12" MAX/ WP BELL OR NO MINIMUM SPEAKER/ TO CEILING STROBE EXTERIOR WALL FROM FACP OR PREVIOUS SLC DEVICE ADDRESSABLE SLC LOOP CABLE, TYP. ® T9 SUP A (-) SLC (+) T2ic ® T8 SUP A (+) T7 �U; EOL S1 T6SUP A/B ( ) 3 013= 3z O TENS ONES TO NEXT O O S -MONITOR O 00 SLC DEVICE MODULE SK- MONITOR MODULE 1 Q SCALE: NTS -'CLASS B WIRING SHOWN NOTES. z cn 0 z 1111- 0 U � � w 0 0f co 0 of IL Q w � W c >M u_ w zLO � O � L) O J O� 2 J � W z O J J Ln W cry m Li ('V C~/)0000 Lu Lin Q Q I-_ I ri In 2 rn Q z = o 0 z M M C�0 J 41 4- J Li m F I R2022-0110 RESUB Nov 29 2022 CITY OF EDMONDS DEVELOPMENT SERVICES 3® 2 1 DEPARTMENT O SYSTEM SENSOR O B300-6 BASE REVIEWED BY: C. RUSSELL NICET LEVEL III CERT NO. 120520 O, TENS: 30NES ADDRESS SETTING IS LOCATED ON THE DETECTOR. SHOWN ON BASE FOR REFERENCE ONLY. DETECTOR BASE --�13300-6 SCALE: NTS -'CLASS B' WIRING SHOWN NOTES: ADDRESSABLE SLC LOOP CABLE, TYP. FROM FACP OR PREVIOUS NAC O DEVICE FROM FACP OR 9 � 0 1 O9 AUDIO E ECT PREVIOUS NAC TO NEXT DEVICE NAC DEVICE NOTIFICATION 0 0 Do CIRCUITS 7171 CABLE, TYP. O7E.O.L.D. C SYSTEM SENSOR STROP E.O.L.D. E.O.L.D. TO BE PLACED ON P2RK/P2RHK SYSTEM SENSOR P2'X'L/PC2'X'L L-SERIES LAST DEVICE OF HORN/STROBE HORN/STROBE RESPECTIVE NAC CIRCUIT. 0 CANDELA SELECT O P2'X'L/PC2'X'L L-SERIES HORN/STROBE 3 SCALE: NTS NOTES: -'CLASS B' WIRING SHOWN -'X' DENOTES COLOR: R = RED W = WHITE ADDRESSABLE SLC LOOP CABLE, TYP. TO NEXT NAC DEVICE E.O.L.D. TO BE PLACED ON LAST DEVICE OF RESPECTIVE NAC CIRCUIT. P2XK/P2XHK HORN/STROBE WP SCALE: NTS NOTES: -'CLASS B' WIRING SHOWN -'X' DENOTES COLOR: R = RED W = WHITE H = HIGH CANDELA OUTPUT V J 0 z OC G 0 ui LL O 0L O G O J_ Q uj 0 ~ 0 J Q W U_ Q > z W C� Z O Q L m 5� O N LLJ z < Q J w w w 0 W W N Ln O a W O 0- DRAWING SIZE: E SIZE 730"x42" DRAWN BY: J. LUCHSINGER DATE DRAWN: 10/07/2022 REV DATE: 11/28/2022 REV 2 BUSINESS LICENSE # SECURSN790NE FIRE ALARM DEVIC SCALE: NONE E DETAILS ELECTRICAL LICENSE # SECURSN954JG FA.4.02 ri LU a 120 VAC CONNECTION 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 ALARM SUPERVISORY TROUBLE NLCENCE O O O O REVEW STATICS �XT D POWER O ❑ mimaywspp madal (67700 asr.aNT FHKIIE Z2ARM COO [> 9 TMOL MGHTCOO G� �i] M �9 C�La40O G3 ❑ � o o❑o 0 El ❑ will ® ® Ki m [ BATTERY CONNECT PHONE LINES RELAY 2 RELAY I I KUUtSLt Lc 11 J U U I SLG VKU NO C NC NO C NC NO C NC- +� - + BATTERY 12V 7AH D6700 F 2 SCALE: NTS INAG 1 NAG Z BATTERY 12V 7AH RE ALARM CONTROL PANEL 0 SLC LOOP CLASS'A' BLK 120 VAC GND CONNECTION WHT 5496 PS - I + pibUtj A I is O O 0 s JL Eb°s SILENT KNIGHT s«,„(-)r, + SK-ISO s«N(.)r3 + ADDRESSABLE E«OUT(-)r3 + ISOLATION MODULE E`°°°r'"r° + SILENT KNIGHT O O ISO-X O D NOTE: SLC LOOP DEVICES ARE SHOWN FOR CONNECTIONS ONLY AND DO NOT REPRESENT THE COMPLETE SYSTEM. SEE THE RISER DIAGRAM AND FLOOR PLANS FOR DEVICE LOCATIONS AND WIRING BETWEEN DEVICES. PRESSURE OR � O s ®s O TAMPER SWITCH +rn Ea °wRi-)LED — TYPICAL + r, E. I-Fu) sic(-)n + + r93U -) s«(.)rz + o T— TEN ONES --r O OSILENT SK-MONIITORTO O SILENT KNIGHT SK-MONITOR SINGLE MONITOR MODULE FOR PRESSURE, TAMPER, OTHER SWITCHES -TYPICAL z W 0 z F— 0 U U) elf w W 0f 0 2 of U) 0 of LL Q LU � D LU O7 of U) LL z 0 d 22 U V) LU O O O PRESSURE J ® SILENT KNIGHT OR TAMPER LEo SK-MONITOR-2 SWITCH - E�-)r, + DUAL MONITOR MODULE C� LUTYPICAL + asp°„.) sL.0 Tz+ PRESSURE, WATERFLOW, IL + 1$0' TAMPER, OTHER Q NC r +"s„°SWITCHES-TYPICAL z Lo NO + coM + T)—1 SK-MONITOR-20 0 WATERFLOW Lr1 INDICATOR SWITCH L) N O V) op O O J LULr) Q M ❑ _ .Q�� J a z=oo w z �zM� 0 CD J 1-0 J +- J � J LU W � m m s+ BASE FOR HEAT/SMOKE DETECTOR BASE z+ DETECTORS (INCLUDED WITH DEVICE) �1 BATTERY BATTERY FIR2o22-0110 12V 7AH 12V 7AH SILENT KNIGHT 5496 POWER SUPPLY CLASS 'A' SCALE: NTS NOTES: - 6.0 AMPS MAX. - 6 NAC CIRCUITS - REFER TO BATTERY CALCULATIONS FOR BATTERY SIZES. 0 0 0 SB 586OR ANNUNCIATOR SA (BACK VIEW) SBUS O N S+ �� DIP SWITCHES S- 45 FAC P 6700, 5860 ANNUNCIATOR SILENT KNIGHT SK-ISO ST Eo s« , + ADDRESSABLE —OLT3 11 ,-OTz ISOLATION MODULE s«aUT(.)T° + �7- SILENT KNIGHT O ISO-X O O ❑ ALARM FIRE ALARM ANNUNCIATOR ❑ SUpERASO°3Y ❑ TROUBLE El SILENCED ❑ POWER ®KNIGGLLT CD CD CD 1EE1 m cc CD CD CD 5860 ANNUNCIATOR SCALE: NTS . PS 5496 AND DEVICES SIL C AE P1 4DDEVICE WIRING CLASS 'A' SLC LOOP SCALE:NTS NOTE: THESE DEVICE LAYOUTS ARE FOR GRAPHIC DEPICTION ONLY, AND DO NOT ACCURATELY REFLECT THE LAYOUT OF THE EXISTING DEVICES AS THEY ARE INSTALLED. NOT ALL DEVICES MAY BE USED. RESUB Nov 29 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVIEWED BY: C. RUSSELL NICET LEVEL III CERT NO. 120520 w � U 0 Z > w O o 0 z Q ui LL C) O L0 0- LL O � 0- CDO CV Q uW Q C 00 U z J Q z V) Q z (0 Q 0 I-- 2 C� 0 z o a 0 O Z u C)p C)LLI Q O LUz p CO w W U w 7 O U LU U N�L w LL DRAWING SIZE: E SIZE 30"x42" DRAWN BY: J. LUCHSINGER DATE DRAWN: 10/07/2022 REV DATE: 11/28/2022 REV 2 BUSINESS LICENSE # SECURSN790NE ELECTRICAL LICENSE # SECURSN954JG SCALE: NONE FA.4.03 N N 0 0 04 N w O 0 N N Q o � p z c/) O z O U U) elf w c/) Of Z J OU 2 z O O Of LL < a w 22 D w U U) � w cn LL p N � V) (/) W zLO O 0 Y un C.i N p c~n000 '� Lu n <3: Q M _ QI�� J C7 z=oo w z �zM� LL 0 J CD J a-' � J J W W m mw < 0 U) Lu Lu z w w w w F I R2022-0110 RESUB Nov 29 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVIEWED BY: C. RUSSELL NICET LEVEL III CERT NO. 120520 0 Z OC G 0 w L.L O �� z LL O O ~ 0 � LLJ o IZ W Q oo O � LL O J Q w Q� z z 2i z z w o — D Q Q 0 � (3 w � O z u V) z N X z w 0 w U U w LL'� � O Q L/) 0- w a 2 DRAWING SIZE: E SIZE 30"x42" DRAWN BY: J. LUCHSINGER MATRIX SEQUENCE OF OPERATION DATE DRAWN: 10/07/2022 SCALE: NONE REV DATE: 11/28/2022 REV 2 BUSINESS LICENSE # SECURSN790NE ELECTRICAL LICENSE # SECURSN954JG FA.5.01 H FIRE ALARM MATRIX SEQUENCE OF OPERATION � v z -- NOTES: Z � � z 1 -SYSTEM WILL ATTEMPT TO CALL CENTRAL � � STATION, IF ABLE a � a 11J � 2 -DELAY OF 6 HOURS Z v � O a � O w v .. � � a � � _ m z0 V V O W Z = IZ m N a � fn ~O W W N W N J V Z Z Z � J � 2 N J LL W m Q z � o� a � a o 0 m � � �' cn -' a � w g t� '� a z O a > a > � W W X � m � W J J a � v O cn w z z a cn w w J V V � H H H H C.) W � � a a a a � ai GENERAL FIRE ALARM MANUAL PULL STATION SMOKE DETECTOR DEVICE TROUBLE FACP TROUBLE PHONE LINE TROUBLE FACP AC POWER FAIL POWER SUPPLY AC LOSS POWER SUPPLY TROUBLE FACP SILENCE FACP RESET TWO-WAY COMMUNICATION COMM. LOSS AC LOSS FIRST FLOOR FLOW SWITCH ELEV. RECALL SMOKE SECOND FLOOR FLOW SWITCH ELEV. RECALL SMOKE ELEVATOR SHAFT/MECH. RM. SHAFT SMOKE DETECTOR SHAFT HEAT DETECTOR PIT HEAT DETECTOR MECH. HEAT DETECTOR MECH. SMOKE DETECTOR ELEVATOR POWER LOSS FIRE SPRINKLER SPRINKLER TAMPER/PIV LOW TEMP SENSOR FLOW SWITCH BUILDING LOSS OF AC TO BUILDING