Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED FIR2022-0110+Fire_Alarm_Equipment_Specification_Sheets+10.28.2022_11.41.42_AM+3191215
GSECURITY RECEIVED 10/20/22 S 0 L U T 1 0 N S Oct 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIR2022-0110 Port of Edmonds 336 Admiral Way Edmonds. WA 98020 Fire Alarm System Product Submittals Bellingham Lock & Safe, A Part of Security Solutions —Locally Owned for Over 100 Years 1619 N. State Street I Ph: 360.734.4940 I www.securitysolutionsnw.com Bellingham, WA 98225 Fax: 360.647.9540 QSECURITY S 0 L U T I 0 N S BELLINGHAM LOCK & SAFE Submittal Device List: Manufacturer Part Number Description ✓ SILENT KNIGHT 6700 FIRE ALARM PANEL SILENT KNIGHT 5860G ANNUNCIATOR SILENT KNIGHT 5496 POWER SUPPLY BOOSTER PANEL SILENT KNIGHT SK-PHOTO-W SMOKE DETECTOR SILENT KNIGHT SK-ISO ISOLATION MODULE SILENT KNIGHT SK-MONITOR MONITOR MODULE SILENT KNIGHT SK-MONITOR-2 2INPUT MONITOR MODULE SILENT KNIGHT SK-PULL-SA INTELLIGENT PULL STATION SILENT KNIGHT SK-RELAY RELAY MODULE SILENT KNIGHT SK-RELAYMON 2 DUAL RELAY MODULE SYSTEM SENSOR 5621 HEAT DETECTOR, FIXED TEMP & ROR SYSTEM SENSOR 5623 HEAT DETECTOR, FIXED TEMP SYSTEM SENSOR P2RK HORN STROBE, WALL, RED, OUTDOOR SYSTEM SENSOR P2WL HORN STROBE, WALL, WHITE SYSTEM SENSOR PC2WL HORN STROBE, CEILING, WHITE SYSTEM SENSOR SWL STROBE, MULTIPLE CD, WALL, WHITE POTTER ELECTRIC RTS-0 ROOM LOW TEMP SWITCH HONEYWELL HWF2V-COM I FIRE COMMUNICATOR —THIS IS ONLY SUPPLIED IF THERE IS A MONTIORING CONTRACT WITH SSNW Honeywell ®SILENT' i MC. T AS K11 Addressable Fire Alarm Control Panels Addressable Fire Alarm Control Panel The 6700 is an addressable fire alarm control panel (FACP) that is a direct replacment for the 5700 FACP. The 6700 can be configured to achieve a point capacity of up to 100 points. It has one built-in signaling line circuit (SLC), which can support 50 System Sensor' (SK) sensors and 50 SK modules or 50 Hochiki® (SD) devices. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single -point communications. The 6700 also has a built-in, dual -line POTS and IP communicator with additional cellular options available. The 6700 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function buttons to help automate tasks and reduce time spent at the panel. SWIFT® wireless compatibility provides options for wireless detection through a Class A mesh network. It is ideal for hard -to -wire locations, buildings where new wiring is not allowed, or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard -wired 6700 compatible devices. SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. The 6700 also has a form-C trouble relay, two programmable form-C relays, along with powerful features such as drift compensation, pre - trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. FEATURES 84 BENEFITS • Capable of providing up to 100 points to satisfy smaller installation needs • Connect up to 17 panels on one site with convenient single - point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models • Convenient field-upgradeable firmware • Built-in dual path POTS and IP communications with optional cellular models available for reliable backup reporting • 6860 annunciator with a 4 x 40 large display • Four user - programmable buttons minimize time spent executing complex or routine tasks • Built-in USB interface for convenient and quick programming 6700 The 6700 supports a variety of devices, including the 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL power module, and SK or SD devices. • Programmable date setting for automatic and convenient Daylight Saving Time changes • JumpStart® auto programming reduces installation time • 125 software zones and 125 output groups for flexible design options SIGNAL LINE CIRCUIT (SLC) The 6700 SLC loops support multiple device types, maintenance alerts, and a built-in sensor test to comply with NFPA 72 calibration testing requirements. INDICATOR LIGHTS • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Trouble (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power (Green): Flashes forAC failure; solid when power systems are normal USERINTERFACE The 6700 built-in 4 x 20 annunciator with 80 character LCD display and large easy -to -use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanicalfirefighter's key ora valid 4- to 7-digit operator's code. PROGRAMMING The 6700 system offers several options to simplify and speed-up programming. JumpStart° auto programming minimizes programming required to start a new system. The built-in keypad, or the 6860, 5860 or 6855 remote annunciators give you on -site access to current system programming. Programming can also be accomplished using the Windows° -based Honeywell Fire Software Suite (HFSS) program. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows° software system configuration tool to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a PC running Microsoft' Windows°. ADDITIONAL INFORMATION Twisted -unshielded pair wire is recommended. The 6700 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NPFA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signaling services • UL Listed: S2766 • CSFM 7165-0559:0501 • FDNY COA# 6250 ORDERING INFORMATION 6700: Addressable Fire Alarm Control Panel. (Red cabinet) A@] b I ]_%9I.1114Fe12 R UR [A /e%%] �l 6860: 4x40 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860:4x20 LCD remote fire annunciator. 5860 is gray; 5860R is red 6855:4x20 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED / 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6700 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories, visit www.sitentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. Page 2 of 4 — 351607:B 9/26/2018 SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detectorwith thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T. Reflected beam smoke detector with testfeature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended airspeed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (135°F), white SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-ROR-W: Fixed rate of rise detector (135°F), white SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (19019, white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-T. Photoelectric smoke detector with thermal (135°F fixed temperature) SK-PHOTO-T-W: Photoelectric smoke detector with thermal (135°F fixed temperature), white SK-PHOTOR: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2:Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module B300-6(-IV): 6" base for SK-W Series B210LP: 6" mounting base 13501(-BL,-IV,-WHITE):4"flangeless base B501:4" Flangeless mounting base B200S(-IV,-WH): Intelligent sounder base B200S: Intelligent sounder base B200S-LF(-IV,-WH): Low -Frequency intelligent sounder base B200S-LF: Low -frequency intelligent sounderbase B224RB(-IV,-WH): Relay base B224RB: Relay base B224B1(-IV, WH): Isolator base B224B1: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-61B: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for theSD505-DUCTR SD505-DUCT:Addressable Duct Smoke Detector. SD505-DUCTR: Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 1350E-150OF(OOC-370C). SD500-LIM:Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.sitentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. it is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T. Wireless Multi -criteria photoelectric smoke detector with thermal detection (135°F fixed temperature) and 3510W 4" base WSK-HEAT: Wireless Heat, (135°F fixed temperature) and B51OW 4" base WSK-HEAT-ROR: Wireless heat, ROR (135°F fixed temperature) and B510W 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFTTools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power -limited notification appliance circuit outputs. 5883: Relay interface. Provides 10 Form C relays. 5824: Serial/Parallel printer interface module for printer connection. 5895XL: Powersupplywith six Flexput° circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8°W x 10-3/16"H x 3"D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL -MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-I13-2: Remote reporting via the Internet. Requires a VisorAlarm® receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6700 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode, transmitter and receiver SK-FSL: Fiber -Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6° D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. Page 3 of 4 — 351607:13 9/26/2018 IlswtsnoH r✓ana niarva SILENT 5860 Remote Annunciator EZ301 KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy -to -use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error -free system operation. All operations —including reset, silence, detector status checking, fire drill, and programming —are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description Features include an 80-character backlit LCD providing easy -to - understand system messages. The annunciator is ergonomically designed with over -sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Features • 80-character backlit LCD display (4 lines with 20 characters on each line) • Tactile and audible feedback • Accepts user codes or fire fighter's key • Larger keypad buttons for system reset and silence • Install up to eight 5860s per FACP • Available in red or light gray • Support for simultaneous use of multiple 5860s • RS-485 interface to panel • Operation and appearance is identical to 5860 built-in annunciator • On -board piezo sounder audibly indicates alarms, troubles, and supervisones • Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions • Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) • UL listed, complies with NFPA 72 • CSFM approved Electrical Specifications Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Max Per System: 8 Mechanical Specifications Physical 9.1" W x 7.4" H x 1.5" D (23.1 W x 18.8 H x 3.8 D cm) Shipping Weight: 2.8 Ibs (1.3 kg) Color 5860R: Red 5860: Gray ..Mon Neu A . Mae r 5860 Environmental Operating Temperature: 32°F — 120°F (0°C — 49°C) Humidity: 10% — 93% non - condensing Compatibility The 5860 is compatible with the following FACP's: • 5820XL Addressable Fire Control Panel • 5820XL-EVS FACP with Emergency Voice System • 5808 Addressable Fire Control Panel • 5700 Addressable Fire Control Panel Listings NFPA 72; UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. IX; FM Approved 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. VVIew Rmr. Up la NXID NnH Fifl.ii FACP 5W VIP IQ empd :�Wt PV sywm C mpaliblee InkeftKiiigM FACP Ordering Information 5860R Remote Annunicator four line LCD annunciator with 20 characters per line. Red. 5860 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring for surface mounting. 5860TG Gray Trim Ring for surface mounting. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350224 Rev F ° subject to change without notice. For more information, contact Silent Knight © 2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Honeywell ®SILENT' NIQVIGHT 5496 Intelligent Power Module The 5496 intelligent power module is the most cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor°,Gentex°, AMSECO, and Wheelock'. The 5496's advanced microprocessor design is years ahead of the competition. Its switc ode power supply design is up to 50% more efficient than competitivelar mode power supplies. The 5496 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with the Honeywell Silent Knight series fire alarm control panels (FACPs). The 5496 is the cost-effec solution for powering notification appliances required by the Am ans with Disabilities Act (ADA). The 5496 has built-in ANSI cadence:ern. The output circuits can be programmed as notification appliance circuits, or as auxiliary power (configurable for constant, resettabl or holder power). Compatibility The 5496 is compatible with the following Honeywell Silent Knight FACPs: • 6820 / 6820EVS • 5820XL / 5820XL-EVS • 6808 • 6700 • 5808 • 5700 5496 FEATURES & BENEFITS • UL Listedor 6 amps built-in NACs are Communicates to the Lightweight design of notification power • Power su pply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems • 24 VDC filtered output voltage synchronization for appliances from Gentex, AMSECO, System Sensor, and Wheelock • Four power -limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B programmable as notification appliance circuits, or as auxiliary power to be used as constant, resettable, or door holder power • 3 amps per output circuit • Ground fault detector • CSFM approved FACP via 4-wire SBUS adds to ease of (wire runs up to 6000 installation and ft) reduces shipping • AC loss delay option shuts off power to non -essential high current accessories Like magnetic door holders • MEAapproved costs • ANSI Cadence pattern output capability built-in • UL 864,1481 & 1971 Listed • OSHPD (CA) OSP-0065-10 (see accessories) 5496 Technical Specifications Output 1 Output 2 Output 3 Output 4 4 Outputs Programmable as Notification Appliance Circuits, or as Auxiliary Power Auxiliary F ower Gan be Programmed To Be Constant, Resettable, or Door Holder Power PHYSICAL Overall Dimensions:16" H x 12.25" W x 3" D (40.6 x 30.9 x 7.6 cm) Shipping Weight: 8.7lbs ENVIRONMENTAL Operating Temperature: 32°Fto120°F (0°Cto 49°C) Humidity: 10 to 93% relative humidity (non - condensing) ELECTRICAL: AC Input:120VAC at 2.7A Output: 24VDC at 6A Standby & Alarm Current: 10mA Notification/Aux. Power Circuits: 4 Output Configuration: 2 Class A (Style Z) 4 Class B (Style Y) 1 Class A & 2 Class B Amps Per Output Circuit: 3.0 (6.0 amps total) Notification Circuit Output: 20.4 — 27.3VDC C 3.OA each End -of -Line Resistance: 4.7k W EOL resistor For more information Learn more about Silent Knight's Product and other products available by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 www.sitentknight.com required on each Class B circuit Battery Charging Capacity: 7.0 — 35.OAH ORDERING INFORMATION 5496: Intelligent Power Module ACCESSORIES RBB: Remote Battery Box Accessory Cabinet. 16" W x 10" H x 6" D (406 mm W x 254 mm Hx152mm D) SK-SCK: Seismic Compliance Kit AGENCY LISTINGS AND APPROVALS • CSFM approved • NFPA72 • UL listed • FM approved • City of NY: 429-90-E Vol XIV Doc 3503871 Rev FI 11/17 © 2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.sitentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. System Sensor' and Honeywell' are registered trademarks of Honeywell International, Inc This document is not intended to be used for installation purposes. We tryto keep our product information up -to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444 Honeywell SILENT' KNIGHT Honeywell ®SILENT' KMGHT SK-PHOTO-WSerie 1p Intelligent Plug -In Photoel Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitiviIan be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57 fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PH test capable detector for use with DNR Series duct detector housings. FEATURES & BENEFITS • New modern profile for improved aesthetics • Stable communication technique with noise immunity • Low standby current • Two -wire SLC connection • Optional remote, single- gang LED accessory • Dual LED design provides 360'viewing angle • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Built-in tamper - resistant feature • Sealed against back pressure • Expanded color options • SEMS screws for wiring of the separate base • Optional relay, isolator, and sounder bases • Plugs into separate base for ease of installation and maintenance DETECTOR SPACING AND APPLICATIONS Honeywell recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9m). For specific information regarding detector spacing, placement, and special applications refer to NFPA72. System Smoke Detector Application Guide, documentA05-1003, is available at systemsensor.com INSTALLATION The SK-PHOTO-W Series plug-in detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. NOTE: • Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. • When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases. ORDERING INFORMATION SK-PHOTO-W: Photoelectric smoke detector. white. SK-PHOTO-R-W: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, white. SK-PHOTO-T-W: Photoelectric smoke detector with thermal sensing, white. INTELLIGENT BASES B300-6: White, standard flanged low -profile mounting base. B300-6-BP: Bulk pack of 3300-6, package contains 10. B300-6-IV: Ivory, standard flanged low -profile mounting base. B501-WHITE: White, standard European flangeless mounting base. UL listed. B501-BL: Black, standard European flangeless mounting base. UL listed. B501-IV: Ivory, standard European flangeless mounting base. UL listed. B20OS-WH: White, Intelligent, programmable sounder base. B20OS-IV: Ivory, Intelligent, programmable sounder base. B200SR-WH: White, Intelligent sounder base for retrofit applications. B200SR-IV:Ivory, Intelligent sounder base for retrofit applications. B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications. B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. B224RB-WH: White, plug-in System Sensor relay base. B224RB-IV: Ivory, plug-in System Sensor relay base. B224BI-WH: White, plug-in System Sensor isolator detector base. B224BI-IV: Ivory, plug-in System Sensor isolator detector base. ACCESSORIES CK300: Color Kit (includes cover and trim ring), white,10-Pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-Pack. CK300-BL: Color Kit (includes cover and trim ring), black,10-Pack. M02-04-01: Detector test magnet. M02-09-00:Telescoping test magnet. RA10OZ: Remote LED annunciator SMB600: Surface Mounting Kit (flanged). TR300: Replacement trim ring for B300-6. white. TR300-IV: Replacementtrimring for B300-6-IV, ivory. SK-PHOTO-W Series Detector Technical Specifications PHYSICAL COMPATIBILITY For a complete listing of all compliance approvals and Height: 2.0" (51mm) installed in B300-6 base The SK-PHOTO-W series detectors are certifications, please visit Diameter: 6.2" (156mm) installed in B300-6 compatible with the following Honeywell Silent www.sitentknight.com. base 4.1" (104 mm) installed in B501 base Knight fire alarm control panels: Microsoft, Windows, and the Windows Logo are Weight: 3.4 oz (95 g) 6820: Addressable fire alarm control panel registered trademarks 6820EVS: Addressable fire alarm control panel or trademarks of Microsoft Corporation. ENVIRONMENTAL with an emergency voice system. Operating Temperature range: Silent Knight°, System 6808: Addressable fire alarm control panel Sensor' and Honeywell' Photo: 320F to 122°F (0°C to 50°C) are registered 6700: Addressable fire alarm control panel trademarks of Honeywell Photo with Thermal: 320Fto 100OF (0°C to International, Inc. 5700: Addressable fire alarm control panel 38°C) 5808: Addressable fire alarm control panel This document is not UL listed Velocity range: Photo/Photo with intended to be used for Thermal: 0 to 4,000 fpm (0 to 20 m/sec) 5820XL: Addressable fire alarm control panel installation purposes. We tryto keep our product (suitable for installation in ducts) 5820XL-EVS: Addressable fire alarm control information up -to Humidity: 10% to 93% non -condensing panel with an emergency voices stem p g y y date and accurate. We cannot cover all specific applications or anticipate Thermal Ratings: Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements. All 1350F (570C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site. to change without notice. ELECTRICAL RATINGS UL listed: S6173 For Technical Support, Voltage Range:15 to 32VDC peak FM approved caIt 800-446-6444. CS FM: 7272-0559:0523 Operating Current C 24VDC: 20%tA (one communication every 5 seconds with green LED blink on communication) Maximum Current:4.5mA @ 24VDC (one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford, CT 06472 Doc 3516341 Rev A 104/18 r SILENT' 800-328-0103 © 2018 Honeywell International Inc. ® KNIGHT Honeywell ®SILENT' NIGHT SMSO Intelligent Fault Isolator IV The SK-ISO is an addressable line isolator Honeywell Silent Knight Series fire alarm use with the �ls (FACPs). The SK-ISO acts as an automatic switch that opens when the line voltage on the signaling line circuit (SLC) loop drops below four volts. Isolator modules should be spaced between groups of sensors or modules in a loop to protect the rest of the loop. If a short occurs between any two isolators, then both isolators immediately switch to an open circuit state and isolate the devices between them. The remaining s on the SLC loop continue to fully operate. No more than 25 devices a commended for each group. INSTALLATION The SK-ISO mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor' PN SMB500) is available from Silent Knight. FEATURES & BENEFITS • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Isolates short circuits on an SLC loop • Protects the modules on the SLC loop so other devices continue to operate • Standard 4 inch electrical box mounting • SEMS screws for easy wiringUL Listed • CSFM Listed • FM Approved SK-ISO SK-ISO Technical Specifications For a complete listing of all compliance approvals and certifications, please visit PHYSICAL ORDERING INFORMATION www.sitentknight.com. Dimensions:4.5" H x4" W x 0.25" D (11.4x 10.2 x SK-ISO: Line isolation module 6cm) Microsoft, Windows, and Shipping Weight: 6.3 oz (196 ) pp 9 9 9 ACCESSORIES the Windows Logo are registered trademarks SMB500:4" Square Surface Mount Electrical Box or trademarks of ELECTRICAL Microsoft Corporation. Operating Voltage:15 — 32 VDC COMPATIBILITY Silent Knight°, System Standby Current: 450 µA max (not isolating; relay The SK-ISO is compatible with the following Sensor' and Honeywell' closed) Honeywell Silent Knight fire alarm control panels: are registered Isolation Current: 5mA max 6820: Addressable fire alarm control panel trademarks of Honeywell Fault Detection Delay: 250ms min. 6820EVS: Addressable fire alarm control panel International, Inc. Fault Detection Threshold:4V with an emergency voice system. This document is not Line Restoration Threshold: 7V 6808: Addressable fire alarm control panel intended to be used for 6700: Addressable fire alarm control panel installation purposes. We ENVIRONMENTAL 5700: Addressable fire alarm control panel tryto keep our product information up -to Operating Temperature: 32°F — 120°F (0°C — 5808: Addressable fire alarm control panel date and accurate. We 49°C) 5820XL: Addressable fire alarm control panel cannot cover all specific Humidity: 10% — 93% non -condensing 5820XL-EVS: Addressable fire alarm control panel applications or anticipate all requirements. All with an emergency voice system specifications are subject to change without notice. For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford, CT 06472 Doc 350134I Rev F 111/17 SILENT 13 800-328-0103 © 2017 Honeywell International Inc. EMGHT Honeywell SILENT' KNIGHT SK-MONITOR Intelligent Monitor Module The SK-MONITOR is an addressable monitor module for use with Honeywell Silent Knight Series fire alarm control panels (FACPs). The SK-MONITOR is intended for use in intelligent, two -wire systems, where individual address of each module is selected using the built-in rotary switches. The SK-MONITOR supports Class A supervised or Class B supervised wiring to the load device. Conventional4-wiresmoke detectors can be monitored for alarm and trouble conditions. IRF'3flIgWAd1•l,l The SK-MONITOR mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. FEATURES & BENEFITS • Single contact monitor • Panel controlled • Support for Class A status LED that and Class B wiring flashes green in normal state and is • Fully supervised solid red in alarm • SEMS screws for easy wiring • UL Listed • Rotary address switches for fast installation SK-MONITOR ®'zQWEI, sue.. Honeywell SILENT' KNIGHT SK-MONITOR-2 Addressable Dual Monitor Module The SK-MONITOR-2 module is capable of monitoring two separate Class B circuits simultaneously, making it ideal for waterf low tamper switch and flow switch monitoring. The SK-MONITOR-2 is an addressable monitor modulewith two initiating circuits for use with Honeywell Silent Knight series fire alarm control panels (FACPs). The SK-MONITOR-2 acts as an interface to contact devices, such as waterflow switches and pull stations. The SK-MONITOR-2 supports Class B supervised wiring to the load device. Conventional4-wire smoke detectors can be monitored for alarm and trouble conditions.. INSTALLATION SK-MONITOR-2 mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor' part numberSMB500) is available from Silent Knight. FEATURES & BENEFITS • Monitortwo circuits, with unique addresses, simultaneously • Support for Class B wiring • Fullysupervised • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate • Rotary address switches for fast installation • SEMS screws for easy wiring SK-MONITOR-2 SK-MONITOR-2 Technical Specifications To Next Device Two initiating device circuits NFPA Stlye B Power limited 230pA Max C 12VDC max Wiring SK•Monitor-2 Modules PHYSICAL Height: 4.5" H x 4" W x 1.25" D Shipping Weight: 6.3 oz (196 g) ELECTRICAL Operating Voltage: 15 — 32 VDC Standby and Alarm Current: 750NA max C 24VDC (one communication every 5 sec with 47K EOL) End -of -Line Resistance:47KQ ENVIRONMENTAL Operating Temperature: 3212F-1201f (ONE — 49 NE) Humidity: 10%— 93% non -condensing ORDERING INFORMATION SK-Monitor-2: Dual Monitoring Module ACCESSORIES. SMB500:4" Square Surface Mount Electrical Box For more information Learn more about Honeywell Silent Knight and other products byvisiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 For acorn plete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Compatible Face Silent Knight°, System Sensor® and Honeywell' are registered SLC trademarks of Honeywell 0LlT__1JJMEJ International, Inc. AGENCY LISTINGS AND APPROVALS UL Listed CSFM Approved City of New York Approved COMPATIBILITY The SK-MONITOR-2 is compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency mass notification system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency mass notification system. Doc 3501241 Rev E 111/17 © 2017 Honeywell International Inc. This document is not intended to be used for installation purposes. We try to keep our product information up -to date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call800-446-6444. Honeywell SILENT' IQ�IIGHT HoneywelE SILENT' KNIGHT' SK-PULL-SA / SK-PULL-DA Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to activate the station. The SK-PULL-DA is a dual action pull station requiring two motions to active the station. The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel (FACP). Extremely easy to operate, the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal. The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-1/0 surface back box or semi -flush mounted on a standard single -gang with a minimum depth of 2.13°(5.40 cm) or double gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor' PN BG-TR) trim ring if the station is being semi -flush mounted. FEATURES & BENEFITS • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets ADA requirement for 5 lbs maximum pull force to active • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Shell, door, and handle molded from durable LEXAN® SK-PULL-SA SK-PULL-DA • Reliable analog communications for trouble -free operation • Braille text on station handle • Rotary address switches for fast installation • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • UL Listed, including UL 38, Standard of Manually Actuated Signaling System • CSFM Listed • MEA Listed ®'zQWEI, sue.. Honeywell SILENT' KNIGHT SK-RELAY Intelligent Relay Module The SK-RELAY is an addressable relay module for use with Honeywell Silent Knight Series fire alarm control panels (FACPs). The SK-RELAY allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK-RELAY contacts can be used for virtually any normally open or normally closed application. Each SK-RELAY is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the SK-RELAY, the relay is triggered by the FACP. INSTALLATION The SK-RELAY mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor' PN SMB500) is available from Silent Knight. FEATURES & BENEFITS • Two sets of Form C contacts • Rotary address switches for fast installation • Contacts are rated for a variety of amps (see Specifications) • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Relay programming is completely flexible - can be mapped to zone conditions • Polling LED visible through the cover plate • SEMS screws for easy wiring • UL Listed r,+ 0 Honeywell S[1 e \-r xvx; i rr SK—RELAY ®'zQWEI, sue.. SILENT KNIGHT J by Honeywell SK-Relaymon-2 Intelligent Dual Monitor Module with Two Relay Outputs The SK-Relaymon-2 module is capable of monitoring two separate Class B circuits simultaneously, combined with two Form C relay outputs. The SK-Relaymon-2 saves you time and money by reducing what may have taken four modules to accomplish into a single module footprint For more information about the Intelliknight system, or to locate you nearest source, please call 800-328-0103. Description The SK-Relaymon-2 combines two relay outputs and two monitor inputs into one module device. The module is capable of Class B supervised wiring to the monitored devices. It also contains Form C relay contacts allowing the panel to switch the contacts on command. Each monitor input provides an interface between a fire alarm control panel and one or more normally open contact -type devices. Each relay output has its own green LED. Features • Monitor two circuits, with unique addresses, simultaneously • Two Form C relay contacts with each having a unique address • Fully supervised support for Class B input wiring • Relay programming is completely flexible — can be mapped to zone conditions • Individual LED's for each monitored input and relay output • Attractive ivory cover plate • Rotary address switches for fast installation • SEMS screws for easy wiring • UL listed • CSFM:7300-0559:0155 xc. s COMN,� T] •cONN CON ] T14 xo.2 1.1 u¢Tve�rirtu 13 TB T8 L : N'0, I i h A%1:1" I., T,11 SK-Relaymon-2 Installation The SK-Relaymon-2 mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight Compatibility The SK-Relaymon-2 is compatible with the following IntelliKnight FACP's: 5820XL 5820XL-EVS 5808 5700 P/N 350755 Rev D © 2015 Honeywell International Inc. Model SK-Relaymon-2 Intelligent Dual Monitor Module with Two Relay Outputs To Next Device + If Any Wiring to Terminals 7-12 is Not Power Limited, the EA -CB Barrier is Required. The EA -CB Includes a Non -Power Limited Label, Which Must Be Placed Over the Power Limited Terminal Information on the Name Plate Label. Specifications Physical Size: 4.675" H x 4.275" W x 1.4" D (mounts to a 4" square by 2 1/8" deep box) Shipping Weight: 6.3oz (178.6 grams) Electrical Operating Voltage: 15 — 32 VDC SLC Standby and Alarm Current: 1.3 mA Environmental Operating Temperature: 32°F to 120°F (0' to 49° C) Relative Humidity: 10% - 93% non -condensing From Compatible FACP + or Previous Device 47K EOL Resistor ELR-47K Relay Contact Ratings 47K EOL Resistor ELR-47K Current Rating Maximum Voltage Load Description Application 5 = 0.35on-co e 3A 30 VAC Resistive Non -coded Resistive Coded 46A 30 VA L R = 20ms on -co e 0.7A 7 .7 = 5 on co e 0.9A Resistive on -co e 5 5 = U.1b on -co e 3A125 VAC PF 0.35 on -co e Ordering Information: SK-Relaymon-2: Dual Relay/Monitor Module SMB500: Surface -mount electrical box 0 SILENT This document is not intended to be used for installation purposes. We try to keep our product KNIGHT information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, by Honeywell contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com 4,�� SYSTEM 5600 Series Mechanical Heat Detectors System Sensor' 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non -life -safety installations where smoke detectors are inappropriate. Features • Multiple configurations for installations: — Single- and dual -circuit models — Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. • Plain housing for residential installations (Model 5601P) • Easy -to -use terminal screws • A broad range of back box mounting options: — Single gang — 3.5"and 4"Octagonal — 4"square with square to round plaster ring • Reversible mounting bracket Agency Listings 0i @ UDC AR S2101 3016008 CSG?0 7270-1653:0167 FM LISTED APPROVED :03/k� 1W-4 . 1 "135FI51 5621 Multiple configurations. The 5600 series offers a full -line of configurations to accommodate a broad range of applications. Both single- and dual -circuit models are available for low- and high - temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single -gang and octagonal back boxes. And these models accommodate four -square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface -mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/ rate -of -rise units are marked FX/ROR. The 5600 series also provides a post -activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Specifications Mechanical heat detector shall be a System Sensor 5600 series model number , listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single -circuit or a dual -circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90oC), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate -of -rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate -of -rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Maximum Installation Temperature 5601 P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150OF (65.6°C) Operating Humidity Range 5 to 95% RH non -condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194OF (90°C) Weight 6 oz. (170 grams) Rate -of -Rise Threshold 150F (8.3°C) rise per minute (models 5601 P, 5602, 5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact 6-125VAC / 3A Ratings 6-28VDC / 1 A 125VDC / 0.3A 250VDC / 0.1A Input Terminals 14-22 AWG "yd (D 5601 P 5602, 5622 5603, 5623 5604, 5624 5621 Ordering Information 5601 P Single None 135°F (57°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194°F (90°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 1940F (90-C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering `NOTE: Refer to NFPA72 guidelines for 194°F (90°C) Fixed Temperature spacing reductions when ceiling heights exceed 10 feet. 25 feet x 25 feet (7.62m x 7.62m) SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2013System Sensor. Product specifications subject to change without notice. Visit systemsensorcom Phone: 800 SENSOR2 •Fax: 630 377 6495 or current product information, including the latest version of this data sheet. SENSOR" www.systemsensor.com SPDS30001.7/13 4,�� SYSTEM Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40°F to 151 °F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Agency Listings SIGNALING O L F M MEA 7300-1653:187 (outdoor strobes) LISTED approved 7125-1653:188 (horn strobes, S4011 (chimes, horn strobes, horns) APPROVED pp chime strobes) S3593 (outdoor and alert strobes) 3N,'F79 MEA452-05-E 7135-1653:189 (horns, chimes) AIL 0 pf'r S y s t e m S e n s o ar SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40oF to 151 °F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•CircuitT" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151 °F (-40oC to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1-W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) MIMEr "MIRIMM, I 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 Max. Current Draw (mA RMS), 2-Wire Horn Strobe,UL ..Candela 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current •Strobe, DC Input High 16-33 Volts 135 150 177 Candela 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 wit 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output •8-17.5 candela ratings must be reduced in accordance with 16-33 24-Volt Nominal this table. S h S d Volts Volts Reverberant Anechoic StrobeOutput Listed Candela Candela rating at —40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 c Position oun Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 rAlert Advance Diagrams 2.5" 3„ Wall -Mount Horn Strobes IMP U erproof Back Box Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK't 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK"t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK•t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK"t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK't Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK•t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK't Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: Add '-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. f_ SYSTEM ©t to change System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Produc specifications subject02SysmSentnotice. Visit systemsensoccom SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information,DS01 01.3/atestversionofthisdaasheet. AVDS01201 • 3/12 SYSTEM SENSOR Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features F I R E • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only Agency Listings SIGNALING U� FM LISTED APPROVED The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit'M Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR' 2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 1.91-D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.25-D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data 1�1�19Fril.'Si777A.iI `\:ilUf.'i r . 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non -Temporal High 43 47 54 95 N/A 121 155 Non -Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 Max. Current Draw (mA RMS), 2-Wire Horn Strobe,UL 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non -Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.11K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non -Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.11K Non -Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 . Settings 9 and 10 are not available on the 2-wire horn strobes. L-Series Dimensions 3.46 1.25 000 a000000000000 0000000000000 5.27 Lli 0 Compact Strobe / Horn Strobe 4.70 1.91 1.25 5.67IN t o Strobe / Horn Strobe L-Series Ordering Information 5 Compact Horn Horn Wall Horn Strobes Horns P2RL 2-Wire, Horn Strobe, Red HRL Horn, Red P2WL 2-Wire, Horn Strobe, White HWL Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL Compact Horn, Red P2GWL 2-Wire, Compact Horn Strobe, White HGWL Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBWL Wall Surface Mount Back Box, Red Wall Strobes SBBWL Wall Surface Mount Back Box, White SRL Strobe, Red SBBGRL Compact Wall Surface Mount Back Box, Red SWL Strobe, White SBBGWL Compact Wall Surface Mount Back Box, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover All -ALERT models have "ALERT' marking on cover 3825 Ohio Avenue • St. Charles, IL 60174 ©2017SystemSensor. SYSTEM SENSOR- Phone: 800 SENSOR2 •Fax: 630 377 6495 Pforcurreuct current product sumatioochangewihel [nonce. version for current product information, including the latest version of this data sheet. www.systemsensor.com AVDS86502.01/17 4,�� SYSTEM Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Agency Listings SIGNALING & F M LISTED APPROVED 55512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:0503 3057383 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS868-02 - 12/01/2017 • Page 3 L-Series Specifications General L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double - gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit'" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02. 12/01/2017 • Page 2 UL Current Draw Data RIJNMFVf1RjM- T.i. nja;' 1IFFSL*Irii1MECi11 L max. 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16--,33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non -Temporal High 43 47 54 95 N/A 134 164 Non -Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.11K Non -Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non -Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non -Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.11K Non -Temporal High 108 135 179 200 225 255 289 3.1 K Non -Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data StrobeHorn .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 L-Series Dimensions 0.83" di (173 n 2.47" (62.7 mm) 1.37" (34.8 min) Ceiling -Mount Horn Strobes A0545-00 A0494-01 6.92" r+— (175. Ceiling Surface Mount Back Box 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT PC4WL 4-Wire, Horn Strobe, White Accessories 2.5' (64 mm) O A0546-00 TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling -listed horn -only device, see AVDS865 "Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications". 1-01 SYSTEM ©t to c System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensoccom SENSOR" Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information,6,-02ngthe latestversion ofthisdata sheet. AVDS868-02 • 12/01/2017 SYSTEM SENSOR Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features F I R E • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only Agency Listings SIGNALING U� FM LISTED APPROVED The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit'M Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR' 2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 1.91-D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.25-D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data 1�1�19Fril.'Si777A.iI `\:ilUf.'i r . 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non -Temporal High 43 47 54 95 N/A 121 155 Non -Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 Max. Current Draw (mA RMS), 2-Wire Horn Strobe,UL 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non -Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.11K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non -Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.11K Non -Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 . Settings 9 and 10 are not available on the 2-wire horn strobes. L-Series Dimensions 3.46 1.25 000 a000000000000 0000000000000 5.27 Lli 0 Compact Strobe / Horn Strobe 4.70 1.91 1.25 5.67IN t o Strobe / Horn Strobe L-Series Ordering Information 5 Compact Horn Horn Wall Horn Strobes Horns P2RL 2-Wire, Horn Strobe, Red HRL Horn, Red P2WL 2-Wire, Horn Strobe, White HWL Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL Compact Horn, Red P2GWL 2-Wire, Compact Horn Strobe, White HGWL Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBWL Wall Surface Mount Back Box, Red Wall Strobes SBBWL Wall Surface Mount Back Box, White SRL Strobe, Red SBBGRL Compact Wall Surface Mount Back Box, Red SWL Strobe, White SBBGWL Compact Wall Surface Mount Back Box, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover All -ALERT models have "ALERT' marking on cover 3825 Ohio Avenue • St. Charles, IL 60174 ©2017SystemSensor. SYSTEM SENSOR- Phone: 800 SENSOR2 •Fax: 630 377 6495 Pforcurreuct current product sumatioochangewihel [nonce. version for current product information, including the latest version of this data sheet. www.systemsensor.com AVDS86502.01/17 CP� POTTER The Symbol of Protection C UL US LISTED Application The RTS Series complies with the requirements of NFPA 13 and 72 for a room temperature switch to operate at 40°F to protect a dry pipe valve from freezing. The RTS can also be used for other temperature detection applications. Operation The normally open detector, RTS-O, will close the contact when the temperature drops below 40°F (4,5°C). The normally closed detector, RTS-C, will open the contact when the temperature drops below 40°F (4,5°C). The detector will automatically reset to the normal state when the temperature rises above 40°F (4,5°C). The RTS Series Room Temperature Sensors are precision engineered, designed and manufactured for commercial or residential use. RTS-O/RTS-C ROOM TEMPERATURE SWITCH Listings: UL, cUL Listed Enclosure: White ABS Dimensions: 2 1/16"W x 3 7/16"L x 1 1/4"H (5,2cm W x 8,7cm L x 3,2cm H) Sensor: Epoxy sealed stainless steel case, bi-metallic operating mechanism. Contacts: Silver clad, available normally open or normally closed Electrical Rating: 1 Amp at 24VDC Temperature Setting: 40' f5°F (4,5° f3°C) Terminals: Screw Terminals Mounting: Wall Mount, Surface RTS-0 Stock No. 1010108 RTS-C Stock No. 1010109 Description Each unit consists of a bi-metal operating mechanism, featuring hermetically sealed precious metal contacts, N.O. or N.C., which automatically reset for repetitive operation, eliminating the need for sensing element replacement. Small compact design, highly resistant to vibration and corrosion. Easily installed using the enclosed hardware or adhesive mounting pad. Screw terminals permit easy installation in single or multiple detector circuits. Features: • Easily installed • Completely sealed sensor, moisture and vapor resistant • Highly resistant to vibration and corrosion • Highly sensitive to temperature changes • No sensitivity loss due to aging • Repetitive operation without the need to replace sensing elements • Small compact design • Precision and quality at low cost Customer: Project: Engineer: Architect: PRO or PO: QTY: Potter Electric Signal Co., LLC • St. Louis, MO • Cust Service: 866-240-1870 • Tech Support: 866-956-1211 • Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8820013 - REV J PAGE 1 OF 1 6/11 i4wr "OM SERIES LTE / IP Single or Dual Path Commercial Fire Communicators The HWF2-COM Series LTE / IP fire communicators are single or dual path commercial fire alarm communicators that offer Contact ID reporting with any FACP (fire alarm control panel) with a built-in dialer. Models include: HWF2A-COM (AT&T LTE & IP) HWF2V-COM (Verizon LTE& IP) Both models connect directly to the primary or secondary communication ports of a fire panel's digital alarm communicator transmitter (DACT). Three selectable reporting paths include: LTE cellular only, IP only, or IP primarywith LTE cellular backup. All signals from the HWF2-COM Series are delivered to the AlarmNet° network control center which routes highly encrypted, cybersecured Ethernet data packets via a customer -provided Internet connection or LTE cellular network to the appropriate central station. The Alarm Net' network control center is fully redundant and monitored 24/7. Installation and programming are easy using the handheld 7720P Programming tool. FEATURES AND BENEFITS • LTE and IP connection tested every day • Three selectable reporting paths: LTE cellular only, IP only, or IP Primarywith LTE cellular backup • Requires no change to the existing FACP configuration • Connects directly to the primary and secondary telephone ports of a DACT • Plan choices range from 5 minute, 60 minute, 6 hour, and 24 hour supervision intervals • Operates overthe following communication protocols: LTE, HSPA+(4G) HSPA (3G) • Works over any type of customer provided Ethernet 10/100 based network connection (LAN or WAN), DSL model or cable modem • Data transmits over standard Contact ID protocol but is secured with the industry's advanced encryption standard (AES 256 bit) • Supports both dynamic (DHCP) or public and private Static IP addressing • Reliable connection: IP and cellular connection tested every day • Built-in, standalone power supply module. Onboard charging circuit design accommodates battery backup. Includes primary power and battery supervision • Diagnostic LEDs indicate signal strength and status • Choice of LTE provider services • QOS: Quality of Service diagnostics via AlarmNet conveys vital communicator information including signal strength, message path used, and when the message was received • 7720P Handheld programmer for easy setup Honeywell The HWF2-COM LTE/ IPfire communicators operate over the most modern and common cellular networks including LTE, 4G and3G. They connect to any customer provided Ethernet 10/100 base network connection (LAN or WAN), DSL or cable modem. Selectable reporting path feature allows the radios to be configured for a single or dual path, while providing appropriate supervision intervals based on NFPA 72 requirements. Selectable paths and supervision timing intervals include: UCCCVI_00==_ESCRIPTOW PATH 2010 Cell Single path, cellular 2010 1 P 2010 IP & Cell 2013 Cell 2013 1 P 2013 IP & Cell OPERATION Single path, IP Dual path, IP and cellular Single path, cellular Single path, IP Dual path, IP and cellular SUPERVISION'9 TIMES 01 5 Minutes 5 Minutes 24 Hours 60 Minutes 60 Minutes 6 Hours When an event occurs, the FACP goes off -hook to dial the central station. The HWF2-COM Series dialer capture module detects the off -hook condition and providesthefire panelwith a dialtone. When the fire panel detects the dialtone, it begins dialing the central station. After the dialing is completed, the dialer capture module returns a signal to the fire panel. The fire panel then sends the Contact ID reports to the dialer capture module, which in turn sends a signal after the report is successfully received from the fire panel. The dialer capture nodule sends the Contact ID reports to the HWF2- COM Series communications module. When allthe reports are sent, the fire panel goes on -hook. The HWF2-COM Series communications module then transmits the messages to the central station either over the LTE network or the Internet (depending on configuration). FIRE COMMUNICATOR / PANEL CAPABILITY The HWF2-COM Series is compatible with fire alarm control panels that use the Contact ID communications format as described in the SIA DC-05 standard. EASY TO PROGRAM The HWF2-COM communicator can be pre-programmed using the 7720P programmer to enter all central station information. This is saved to the HWF2-COM communicator panel memory. When the HWF2-COM is installed at the site and connected to the Internet/ Intranet, it registers with the AlarmNet Receiver. For most installations, the only required parameters are: • Primary City ID (two digits), obtained from your monitoring station • Primary Central Station ID (two digits), obtained from your monitoring station • Primary Subscriber ID (four digits), obtained from your monitoring station • Communication Module MAC ID, and MAC CRC number located on the outside of the box and inside of the module All parameters are assigned by the monitoring station. ALARMNET AlarmNet communications technology provides a highly reliable alternative for the transmission of alarm signals. The network provides extensive coverage in the United States and Canada. The AlarmNet Network Control Center processes signals from powerful servers in multiple locations equipped with 24/7 infrastructure support. Redundant hardware servers, real-time backup databases, and generators with battery backup at all locations ensure continuity of service. Signals from AlarmNet are transmitted to central station receivers using multiple communication paths consisting of the Internet, LTE radio network, or toll free plain old telephone service (POTS). Visit AlarmNet.com to learn more. INSTALLATION REQUIREMENTS, UL COMPLIANCE To meet UL864/NFPA requirements, ensure the following: • HWF2-COM Series must be installed in accordancewith the National Fire Protection Association (NFPA) standards 70 and 72 • HWF2-COM Series must be mounted in the same room and within 20 feet of the fire panel. • HWF2-COM Series and all equipment used for the IP connection (e.g., router, hub, modem, etc) must be UL-listed, powered from an unswitched branch circuit, and be provided with appropriate standby power. • HWF2-COM Series must use the 7AH battery (not included) to provide 24 hour backup capability Page 2 of 3 — DH-62010:13 • 6/27/2019 3HT 3AUTU9 ZI TAHW 3W TI 3NAM 119wt9noH