REVIEWED BLD2023-1271+SI QUALIFICATIONS+10.30.2023_2.41.13_PM+3869680sFa SFA Design Group., LLC STRUCTURAL ENCINEERINC PORTLAND, OR I LIVERMORE, CA . SEATTLE. WA 503.641 -$31 1 1 www.sfadg-com I:11DYN04911MAI October 301h, 2023 RECEIVED City of Mill Edmonds— Building Division Oct 30 2023 ATTN: Building Inspections CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT RE: Special Inspection — Deep Foundation Elements..............RE.VIEW.E�.............. BY CITY OF EDMONDS Dear Building Official: `• BUILDING DEPARTMENT; This letter is meant to summarize the installation and testing of the Safebasements driven push pier system and describe our qualifications to perform the inspections described below. Continuous special inspection is required during installation of deep foundation elements per 2018 CBC Section 1704.2.1. The following is a description of the system and its installation process observed by a special inspector with SFA Design Group, LLC: • The pier installation locations are excavated. • Contractor provides clean straight surfaces and ensures full contact with the back, vertical plate of the bracket and full contact with bottom of footing to ensure proper seating of the bracket. Once retrofit bracket is securely seated to the foundation at proposed pier location the sleeve and lead are inserted through bracket. • The round steel tubes and retrofit brackets are used to stabilize and/or lift settling foundations. Installer adds pier extensions as required such that pier penetrates ground using the weight of the existing structure to apply downward hydraulic pressure on push pier until minimum depth and pressure on plan notes are met, thus indicating sufficient load bearing stratum has been encountered. • Piers are cut to enable attachment of pier cap with threaded rod. • Special Inspector places an independent and calibrated dial indicator with probe aligned vertically to retrofit bracket and begins load testing in accordance with ASTM method D1143 (Quick Method). 20 percent of piers shall be tested to 150 percent of design load. Load testing creep acceptance criteria shall be no greater than 0.04 inches within. If movement is observed greater than 0.04 inches within the 10 minute period the load test shall be held for an additional 50 minutes, the pier is to be deepened and re -tested, or the pier is to be abandoned and replaced with a new pier. If the load test is to be held the pier movements shall be measured at 15, 20, 30, 40, 50, and 60 minutes. The creep versus the logarithm of time shall be plotted. If the creep rate is less than 0.080 inches between 6 and 60 minutes, the load test shall be considered successful. • Once testing has been successfully completed, contractor connects all push piers to individual hydraulic cylinders. Continuous and even downward pressure is applied on piers simultaneously ensuring even force distribution until desired lift or stabilization is achieved. • Finally, nuts at threaded rods are tightened to engage pier cap and lock pier in place. As described herein, the process of performing a special inspection on driven push piers is very simple and well within our experience and capabilities as an inspector to perform. SFA Design Group has performed the analysis, design, and special inspections on thousands of foundation piers in Oregon, Washington, and California over the past four years. Of the hundreds of underpinning projects, below are a few of the projects inspected by the listed special inspectors: Special Inspector: Frank Keenan Project Name: Hernandez Residence Underpinning Permit No.: BLDRA23-0832 Address: 5002 S M St., Tacoma WA 98408 Special Inspector: Frank Keenan Project Name: Bennette Residence Underpinning Permit No.: 23109055 RPB Address: 13121 5811 Dr. SE, Snohomish, WA 98296 Special Inspector: Frank Keenan Project Name: Korbuszewski Residence Underpinning Permit No.: 1018949 Address: 13025 Valley Ave. E, Sumner, WA 98390 Special Inspector: Frank Keenan Project Name: Hendix Residence Underpinning Permit No.: ADDL23-0259 Address: 46805 284th Ave. SE, Enumclaw, WA 98022 If you have any questions or need further correspondence regarding the above statements please don't hesitate to call. Sincerely, SFA Design Group, Inc. Jeff Fitch, P. Eng., PE EXPIRES: 12/24/24