REVIEWED BLD2022-0877+Energy_Calculations+7.5.2022_1.36.12_PM+2970139RECEIVED BLD2022-0877
Jul 06 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
PROJECT:
ADDRESS:
ALTERNATE UA CALC WSEC 2018
JEWELL RESIDENCE
946 Maple St Edmonds WA 98020
FRAMING
INSUL
PROPOSED
ADV /INT/ STD
VALUE
U-VAL
AREA UA
ATTIC AREA' INT
I
R-49
0.026
0.001
VAULTED CEILING, INT
R-38 10.026
i I 0.00;
WINDOWS / GLASS DOORS
0.280
12 3.361
SKYLIGHTS
0.540
0.0011
OPAQUE DOOR AREA
0.200
21 I 4.201
ABOVE GRADE WALLS NET AREA
R-21
0.056
295 16.52
FLOOR AREA OVER UNHEATED;
R-30 i
0.029
0.00!
SLAB ON GRADE(LENGTH) R=O
Fvalue
0.730
14 1
ft1 10.22
BELOW GRADE WALLS 0-2 ft
(
0.056
-
obo,
I 0.00
SLAB 2-3.5 ft LENGTH
F value
0.540
{ ftl 0.00
BELOW GRADE WALLS (2-3.5 ft)
�
0.056
11
0.001
SLAB 3.5-7 ft LENGTH;
F value 10.540
it O.00
BELOW GRADE WALLS (3.5-7 ft)j
0.056
i 0.00
SLAB >7 ft LENGTH
F value 1
0.540
I Ifti 0.00.
BELOW GRADE WALLS (>7 ft),
0.056
0.001
PROPOSED
TOTAL 342 34.30
CODE TARGET
U-VAL
AREA
UA
0.026
0.00'
0.026
0.00
I
0.300
17.4 115%* 1 5. 221
0,500
j
j 0.00'
0.300
_...
21
6.30
0.056
1289.6
Gr**
j 16.2Z
0.029
0.0011
0.540
I 14
ft
7.561
0.045
0.00!
0.590
ft
0.00:
F 0.042
I
0.00'
0.560
i
ft
0.00
0.640
�
f 0.00
0.035
-
ft 0.00
0.500
0.00.
TOTAL
342
35.30
* 15% of the floor area
** Gross
- 15% floor area