REVIEWED BLD2022-0877+Energy_Calculations+7.7.2022_10.04.01_AM+2974999BLD2022-0877 RECEIVED Jul 07 2022 DMONDS Simple Heating System size: Washington State CILOPMTY OF ETSERVI DEVELOPMENT SERVICES Based on Prescriptive requirements of the 2018 WSEC DEPARTMENT Project Information Jewell Residence 946 Maple St Edmonds WA 98020 Contact Information Al Cohen, Architect 330 Dayton St #6 Edmonds WA Heat System FOR COMMON AREA ONLY IN EX GARAGE Design Temperature Edmonds Design Temp Difference Dt 59 Building Cond. Floor Area 116 Ave Ceiling Height in Ft 8 Conditioned Vol in Cu Ft 928 Duct Leakage Coefficient 1.0 (Ducts in Conditioned space) Item Description U-Factor x Area = UA New Windows Vinyl 2 GI Low E Arg Ex windows Vinyl 2 GI Ex Glass Block Doors SC Wood French Doors 2 GI Low E Arg Skylights 12 GI Low E AI-6 0.280 12 3.36 0.300 0.580 0.460 21 9.66 0.280 0.500 Roof (deck) Rigid R-38 Ex Roof R-19 New Roof R-49 0.031 0.049 0.027 New Floor Slab Fully Insul R-10 F= Ex Floor Joist floors R-11 Batts Ex Floor Slab @ grade R-0 F= Ex Floor Slab @ 2' below R-0 F= 0.360 0.056 0.730 41 29.93 0.580 New Wall below Grade 2x4 R-15 New Wall at Grade 2x6+4 R-36 New Wall above Grade 2x6 R-21 Ex Wall above grade 2x4 R-11 Ex Wall below Grade 2x4 R-5 0.076 0.033 0.054 295 15.93 0.088 1 0.066 Sum of UA = 58.88 Envelope Heat load 3474 UA x Dt Air Leakage Heat Load 591 Vol x 0.6 x Dt x 0.018 Design Heat Load 4065 EHL + ALHL Heat Load 4065 DHL x 1.0 Convert Btu / hr to electric Watts: 1191 Btu per hr / 3413 KW * 1.5 max: 1,786 Proposed Electric In -Wall heater 150OW