Loading...
APPROVED FIR BLD RESUB2 BLD2023-0060+Plan_Set+3.24.2023_4.47.52_PM+3442918Edmonds Work, _ _ _ _ _ _ _ _ POOL _ _ _ _ _ _ _ _ Add,- 6082ND AVEN ------ Own ------ SUEHLM,AIER - - - App.ved Date - 3/30/2023 Boullding ORaial'i •� W. W O L STARTE IAreORA& „pgggae An approved barrier is required around all APPROVED I residential swimming pools. Barrier must be I Approved PLANS MUST BE ■ designed per Section 305 and 305.1 of the ■ OEM ChrLs Burt ON JOB SITE I 2018 International Swimming p Pool and Spa I South County Fire Date: 03/31/2023 ALL WORK SUBJECT TO FIELD ■ Code.INSPECT■ CODECOMIPLrIANCE ■ ■ ■ ■ ■ ■ ■ - GENERAL NOTES: ^".. • POOL SITE MUST BE CAPABLE OF SUPPORTING A LOAD OF 75 LB/SF FOR EVERY FOOT OF POOL HEIGHT. IF POURING A CONCRETE SLAB, IT SHOULD EXTEND A MINIMUM OF 6 IN BEYOND THE POOL'S BOTTOM FLANGE. THE EQUIPMENT END SHOULD EXTEND ENOUGH TO SUPPORT POOLSIDE EQUIPMENT IF NEEDED - SEE PERTINENT DETAILS. • CONTRACTOR TO VERIFY SITE CONDITIONS PRIOR TO.INSTALLATION • ACCESS MUST BE MAINTAINED TO THE WATER -QUALITY SYSTEM, AS WELL AS TO THE POWER UNIT, MEN A HYDRAULIC TREADMILL OR AN AUTOMATIC RETRACTABLE SECURITY COVER IS SPECIFIED & TO THE EXTERIOR OF THE PANEL WHERE OPTIONAL JETS AND/OR LIGHTS ARE INSTALLED. • ENDLESS POOLS CANNOT STRESS ENOUGH THE NECESSITY OF DRAINAGE AT THE POOL SITE, FLOOR DRAINS OR SUMP SYSTEMS SHOULD BE LOCATED ADJACENT TO THE POOL AND TESTED TO ENSURE WATER DRAINS PROPERLY. • THE POOL SHOULD BE BONDED TO ITS ASSOCIATED EQUIPMENT & SLAB OR DECKING, IF APPLICABLE, IN ACCORDANCE WITH LOCAL CODE. • THE ENDLESS POOL SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES, REQUIRED PERMITTING IS THE SOLE RESPONSIBILITY OF THE OWNER. • THE ENTIRE ENOLESS POOL SYSTEM IS ETL LISTED, REF #2001779 AND CONFORMS TO UL STANDARD 01563. INDIVIDUALLY, ALL ELECTRICAL COMPONENTS OF THE ENDLESS POOL ARE UL or CSA APPROVED. • ALL ELECTRIC CIRCUITS MUST BE GFCURCD PROTECTED. • THIS DRAWING MAY NOT REFLECT ALL THE OPTIONS SELECTED BY THE OWNER. %-AUTOMATIC RETRACTABLE SECURITY COVER MUST MEET ASTM F134GAS PER SECTION 305.1 OF THE 20181SPSC. &HEATERS MUST BE CONNECTED TOA READILY ACCESSIBLE ON -OFF SWITCH WITHIN 3 FEET OF THE EXTERIOR OF THE HEATER, AND A CIRCUIT BREAKER FOR THE POWER TO THE HEATER. �-HEATERS MUST BE CONNECTED TO TIME SWITCHES ' THAT AUTOMATICALLY TURN OFF & ON HEATERS, AND PUMP MOTORS TO A PRESET SCHEDULE. / WATER LEVEL` UNDERWATER LIGHTS (access required)- K. RETURN- l 3 1/Z" TYP I SECTION A -A SCALE: Not To Scale _ HYDRAULIC POWER UNIT IN See Detail EP-17.0 for SHELTERED LOCATION WITH HYDRAULIC HOSES TO POOL Electrical Requirements POWER UNIT FOR AUTOMATIC RETRACTABLE SECURITY COVER UNDERWATER LIGHTS (access required) CORNERSTEP- c APEX COPING - DECK BY OTHERS- HOUSING ------------- 4 w LB' 11-8" 39" WATER LEVEL Q a �_1 a B FL 8KI '--'— I+— (-- OATIN MME C 10 3/4" 1-0 1 /S MIN CLEARANCE AUTOMATIC RETRACTABLE FOR ACCESS SECURITY COVER & TRACK PLAN VIEW SCALE: Nat To Scale V41" UTOC IVER MIN LE NCE PROPULSION APEX COPING DECK BY OTHERS WATER -= CORNER ST� CMU/ BLOCK WALLS _ HYDRAULIC HOSE BY OTHERS FITTINGS BEHIND SHROUD UNDERWATER RETURN CHANNEL , CONCRETE SLAB, BY OTHERS w/ANCHOR BOLT SYSTEM, REQUIRES SMOOTH, LEVEL SLAB SECTION S-B SCALE: Not To Scat. . u NSF FULLY IN -GROUND PERFORMANCE ENDLESS POOLS' E MODULAR SWIM SPA BWiMMINe MACHINES 2oe1TIB - N 18010uWn Ma Rued, AtW,PAiS014 �„pLp� RESUB Mar 27 2023 CITY OF EDMONDS DEVELOPMENT SERVICES POOL CONFIGURATJON V (For Additionallnformation, Request Appropriate Detail Drawings from your Design Representative) • Width 7 R Inside Dimension • Length 14 It Inside Dimension • Height 42 in Panel • Anchor Bolt System (Detail EP-2.0) • Standard Liner • Apex Coping • Underwater Return Channsl • Automatic Retractable Security Cover, Front Mount Below Deck (Details Sect EP-6.14 thru 6.18) • Poolside Water Quality System (Details EP-7.0 thru 7.2, EP-3,S) • Corner Step, Rear Left Side (Details EP-8.4, EP-8.5, EP-8a) • Front Underwater Lights (Detail EP-7.3) • Hydraulic Power Unit, 5 HP (Detail EP-7.1.0) • Deck by Others (Details Sect EP-4,O) • CMU Block Wells (Details Seat EP-3) S° MIN CLEARANCE FOR ACCESS RETRACTABLE SECURITY COVER V4 W a a � � l\\ ELECTRIC IP `DRAIN OE 4'1• RECOMMENDED I FOR ACCESS ELEVATION C-C SCALE: Not To Scale FRONT PANEL WATER J QUALITY SYSTEM (protective enclosure not shown) UNDERWATER LIGHTS (access required) CONDUIT MAY E11-: NEEDED FOR SOME \ INSTALLATIONS HYDRAULIC HOES; ro REMOTE POWER uNl I FOR SWIM MACHINE. DRAWING NO. BFS-1 ORIG: 12105/21122 REV 1: 01/03/2023 RESUB ar NOTES: CITY OF EDM DEVELOPMENT,'FPMENT 1. 18" OF ACCESS TO THE REAR & SIIJc PARTMI PANELS IS REQUIRED IF LIGHTS or JETS ARE INSTALLED. 2. LIGHTS & JETS ARE ALWAYS INSTALLED IN THE TOP HALF OF THE PANEL. 3. BOTH LIGHTS & JETS FIT UNDER THE 6-1/2" TOP FLANGE OF THE POOL PANEL. PIT WALL FOR FULLY RECESSED POOL APPEARANCE,BY OTHERS. CONSTRUCTION TECHNIQUES VARY PANEL STIFFENER, QUANTITY VARIES BLOCKING ANGLE (ALTERNATE ANCHORING SYSTEMS AVAILABLE) NO ACCESS REQUIRED See Separate: Pool Vault Drawing (Not to Scale) and Comments on Added Patio and Walkways '—M FLANGE OF POOL PANEL FOAM INSULATION, THERS /ANIZED STEEL L PANEL c UNDEF RETUF SMOO' CONCF BY OTI ,�.. 8" MIN CLEARANCE REQUIRED ACCESS REQUIRED FOR LIGHTS andlor JETS DETAIL NUMBER: FULL HEIGHT CMU ENDWALL EMLEss FULLY RECESSED POOL APPEARANCE EP-3.0 SWlMMINa MA1Q8INE:w 1601 Dutton Mill Road, Aston PA 19014 swim@endesspoolss..wm1800-73243660 ENDWALL CONFIGURATION DETAIL REV: 2018/12l10 Pool Vault Drawing (Not to Scale�ESU B and Comments on Added Patio a lad v?aW3 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT !k P�'r�e�. � E � ♦ q Side View CMU Walls and Floor Decription: --Construction: Rebar reinforced concrete --Thickness: 8 inches --Rebar Thickness: #4 40 grade --Rebar Spacing Walls: Vertical and Horizontal 18 inches o.c. --Rebar Spacing Slab: Horizontal 18 inches x 18 inches o.c. Add Patio and Walkway: --Construction: Rebar reinforced concrete --Thickness: 4 inches --Rebar Thickness: #4 40 grade --Rebar Spacing Slab: Horizontal 18 inches x 18 inches o.c. --Finish: Stamped Side View Top View Sump Pump Hole ♦o RESUB Mar 27 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Endless Pool Electric Heater Manufacturer Specs The electric water heater is an integrated part of the heater/controller model (YEO) built into the Endless pool. The following statements were taken directly from the product YEv3 Tech Book related to the "heat wav" heater. "(H)eat.wav" water heater connections in the ye systems come with a high performance heat wav heater. With no pressure switch, it features in.flo integrated dry -fire protection The heat wav heater is factory configured for 240 V14 kW but it can be converted to a dedicated 120 V1 I kWby simply adding a cable connection (120 V conversion is available on North American in ye-3 models only) heat wav specification summary • Supports 120 V or 240 V • Incoloy@ heater element • Protected by external breaker (no fuse)