Loading...
ENG2023-0579 ROW PERMITRIGHT OF WAY EUC PERMIT PERMIT NU BE City of Edmonds 20 98091 LM www.edmondswa.gov i Description: ZIPLY - REMOVE BO POLE SET HH UG TO NEXT POLE AND OVERLASH ISSUED: 12/07/2023 Address: 115 EDMONDS ST EDMONDS WA 98020-3125 EXPIRES: 06/07/2024 Permit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 27032300101700 NAME TYPE NAME ADDRESS PHONE APPLICANT ARIANNE MOMMSEN 426 E CASINO ROAD, EVERETT WA 98208 (402)670-8384 CONTACT ZIPLY FIBER NORTHWEST, LLC 426 E CASONI RD, EVERETT WA 98208 (402)670-8384 CONTRACTOR ZIPLY FIBER NORTHWEST LLC 426 E CASINO RD, EVERETT WA 98208 (425)231-3928 OWNER CHRISTOPHILIS KONSTANTINOS 155 EDMONDS ST, EDMONDS WA 98020 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE - PER PERMIT $45.00 $45.00 ENG - INSPECTIONS $504.00 $504.00 RIGHT-OF-WAY PERMIT - STANDARD $378.00 $378.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING- WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. RELEASED BY: MAJ DATE: 12/07/2023 Printed: Thursday, December 07, 2023 9:06:49 AM 1 of 2 RIGHT OF WAY EUC PERMIT PERMIT NU �!BEJ City of Edmonds www.edmondswa.gov • • CONDITIONS CONDITION TYPE ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on SOUND AND NOISE weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT COMPLETE A-1 JOB START X-2 ENGINEERING FINAL** E-7 TRAFFIC CTRL E-7 ALLEY OPEN -CLOSED E-7 CONCRETE SIDEWALK E-7 RESTOR LIMITS Printed: Thursday, December 07, 2023 9:06:49 AM 2 of 2 RECEIVED Lti�y of ED%�O� ANC. 1 g90 SECTION A RIGHT OF WAY CONSTRUCTION PERMIT APPLICATION Complete and submit this Application in accordance with the Submittal Requirements outlined in Right -of -Way permit Handout E63. NOV 08 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A" instead of leaving blank. All fields required. Incomplete Applications will be denied. General Info I Project Name5501164 115 Edmonds St. Site Address or if no site address use Property Address at NW corner of project area: 344 SUMSET AVE N. EDMONDS WA Associated Permits: BLD PLN ENG Owner and Entity Holding Franchise (if applicable) Name of Company Ziply Fiber Northwest, LLC Franchise Ordinance No: WN U-17 PointofContact Mike Hakahan Title Engineer Address426 E Casino Rd city Everett State WA zip 98208 Phone 425-949-0230 Email mike.hakahan@ziply.com AuthorizedContractor and Agent •below) Name of Company Ziply Fiber Northwest, LLC Primary Name Mike Hakahan Agent Name Mike Hakahan Title Engineer Title Engineer Mobile 425-949-0230 Address426 E Casino Rd. Email mike.hakahan@ziply.com city Everett I State WA zip 98208 Secondary Name Phone 425-949-0230 Title Email mike.hakahan@ziply.com Mobile City of Edmonds Business License No: 313-013-420 Email State License No: ZIPLYFN782L3 0 Contractor verifies it is currently bonded Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o.02o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as well) ❑ Traffic Control Only (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 ❑ Utility Franchise Work (no associated development) Project Description Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) Telecommunications and broadband provider Ziply Fiber to Remove cable from a pole at the alley between 2nd ave n and 3rd Ave N west to pole C. Remove Pole C and Place a17x30 hh where pole C was located. Remove cable from pole C to Bole B. Pull cable from new HH to Pole B through existing 2" conduit and riser up. Then over -lash cable south crosing Bell St. Continue over -lash east on the south side of Bell St. to a pole at an alley between 3rd Ave N and 4th Ave N. Then oaer-lash nort across Bell Street to Pole 6 and splice cable. RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF JxJ LF SF Alley 72 hours + LF JxJ F SF Parking 72 hours + LF JxJ LF SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: * telecommunications ❑ cable ❑ power ❑ gas ❑ water ❑ sewer ❑ storm 1. CompletedDetails of Work to be Does the utility owner have existin overhead infrastructure in the area of work? x • 2. Will any equipment be added underground or above ground (e.g. pedestals, vaults, etc.)? x If yes, describe: New HH where pole c was removed from. 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility system? X 5. Does the work involve proposed additions to an aboveground utility system? If es: x Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? Details of • to be Completed ®i 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? X City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 If yes, answer the following questions related to project area, i.e. the actual area in which the project is proposed: 6a. Does your project involve wires/cables/lines? If yes: X How many are existing? 13 1 How many are to be added? 10 6b. Does your project involve poles? If yes: X How many poles are existing in the project area? 3 What is the height of the existing poles? unsure How many poles are to be removed? Are additional poles to be laced? How many? I NA I What is the height of the additionalpoles? NA 6c. Are any poles to be modified/rebuilt/replaced? If yes: x How many? I I What is the height of the poles after? Describe the modification/rebuild- SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: �� ` "6 yPX4'4. APPLICANT PRINTED NAME: Michael Comer APPLICANT TITLE: Traffic Controll Specialist NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE 10/23/2023 City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 / Hi SNOIiCl3 I _1V 3-lpa3HOS/ 422' , i AE 50 24 i C9EDM DCL,501-550 f „V 422' O AE 50 24 / C9EDM DCL,25XD+651-675 / / / 137' / NEW U'2524 \�. OLE M °CL'6s1-7 6S'�, A� �0\ y I HLLKWAXX 87832 HLLKWAXX H5022 (HLLKWAXX 2S2) (45-2) (01.1966) / 01 / � A X ' 022 / NO $ / XX 87832) iAGa °GAT AR �W_CAP 50 PAIR /HLLKWAXX 87837\ LE ••B" A�'o� c,4 HLLKWAXX H5022J -� �OFo O 5-51 8 2' 9 25 2 CL,651-675 OTC\ C9EDM D OS S\ (150') (01.1970) T HLLKWAXX87837 OLE "A" �<v� (AE50) (C9EDM ® O Q/ DCL,501-550) HLLKWAXX H5022,45-51+XD,8 O / / 933' FTTP PIGTAIL1000' / CONSTRUCTION NOTES: PATH CREATION -PUD TO PROVIDE PATH (2" PVC)& BORE FROM POLE "B" TO POLE "C" (110") -PAC CABLE TO PLACE 17X30 HH AT POLE "C" -*NOTE* PUD WILL BE REMOVING SIDEWALK PLACING -PLACE 8 PORT TERM TAIL FROM POLE"C" TO POLE"E"- WILL GO THROUGH NEW 2" CONDUIT - FROM POLE"C" TO POLE"B" THEN AERIAL ALL THE WAY TO POLE "E" -PLACE 2ND 8 PORT TERM TAIL FROM LOC "A" AERIAL TO POLE "E"(SPLICE LOCATION) -PLACE 25 PAIR IN NEW 2" CONDUIT FROM POLE "B" TO NEW HH @ POLE "C" -HAND DIG FROM POLE "C" TO NEW HH- EXISTING RISER WILL LAY DOWN TO NEW HH -FIBER - 2 - 8 PORT TERM TAILS- ONE 1000', ONE 1500' -COPPER 25-24 COPPER 110' SPLICING -SPLICE 2 NEW 8 PORT TERM TAILS @ SPLICE LOC @ POLE"E" -SPLICE 25 PAIR @ POLE "B" AERIAL LOCATION AND NEW HH @ POLE "C" 50 PAIR COUNT CHANGE TO 25XD + 651-675 1 WORKER IN 50 PAIR(501-550) ON PAIR 531 LOCATED AT 606 SUNSET AV TERM#6523 -CHANGE COUNT ON COPPER WORKER TO PAIR 656. -CLEAR AND CAP 50 PAIR AT POLE "D" @ 2ND AV N & EDMONDS ST NO WORKERS IN FIBER TERM 87832 REMOVAL -REMOVE AERIAL STRAND, FIBER TAILS, COPPER -REMOVE POLE "C" THE OBJECTIVE IS TO CONVERT FROM AERIAL TO UNDERGROUND SO WE CAN REMOVE POLE "C" DUE TO BO POLE AND CITY 1212' OF EDMONDS ITP PIGTAIL 1500' VERLASHAERIAL/ REQUIREMENTS FOR NEW POLE PLACEMENT RECEIVED COPPER TERMINAL WORKER AT 606 SUNSET AV N- TERM#6523 �l NOV 08 2023 / >RM / CITY OF EDMONDS / DEVELOPMENT / \/ DE)VNI`d2JC8 �GUELNOD4FIc1S0 � �\ TRM Q''2JOd D�81SNOdS32J SI 2JOiOV2J1NOO/ N i �o Z G 60 POLE "E" / \ \/ 0 % \ . C9Fn n _ TRM / \ -loafoad pallluaaad a4l 6ulanp sin000 ao pasneo si fetal spiepuels Alio aad / \ \ leM-;0-l4g1a 4II0 ul sluawanoidwl abeluoi; ao salllllln of abewep Ile aoeldaa/aiedaa pegs lueollddV I CERTIFY THAT THE WORK I COMPLETD ON THIS WORK ORDER AND AS -BUILT IS IN COMPLIANCE WITH ZIPLY QUALITY STANDARDS AS IDENTIFIED ON THE IPQIP CHECKLIST. (SIGNATURE AND DATE) TOTAL ALLOTTED HOURS CONTACT SUPERVISOR IF ADDITIONAL HOURS ARE REQUIRED TO COMPLETE PROJECT CAP. X-TIME MAINT CREW 0 0 0 SPLICING 0 0 0 W.O. DRIVER I CONSTRUCTION START ❑ ETHERNET 7/20/2020 ❑ CIAC IN SERVICE DATE ❑ DAMAGE 8/31/2020 ® OTHER CONSTRUCTION ® FLAGGING ❑ BRUSHING ❑ CONTRACTOR PERMITS MUNICIPALITY: EDMONDS ❑ BLANKET 2 TCP/TRAFFIC ❑ DETAILED (NOT BLANKET) ❑ NO PERMIT REQUIRED JOINT POLE JFN/NJUNS# 100053672 ❑ NO JPN REQUIRED POLE JPN JPN OWNER TO FROM ❑ ❑ Q POWER ❑ Q ❑ CATV ❑ q ❑ FRONTIER ACCOUNT CODES )EI 2411.001 POLES )o 2421.101 OH COPPER �3 2421.201 OH FIBER t] 2422.101 UG COPPER Q 2422.201 UG FIBER a 2441.001 CONDUIT p 34XX.XXX REMOVAL la 64XX.XXX MAINT. POINT OF CONTACT SCHEDULING: JOHN WOOD PHONE: 425-261-1412 ENGINEER: RICH EVANS PHONE: 425-261-6282 FACILITIES: PATRICK WINKLER PHONE: 425-263-4010 FIELDED BY: OSP CONSTRUCTION zi Iy fiber �► HLLK UG CONV JPN 53672 344 SUNSET AV N PROJECT C.O. AREA: 967 NUMBER: 5501164 EXCH. CODE: 51419 DRAWN DATE: ENGR: RICH EVANS NTY: SNOHOMISH DATE 7/8/2020 PHONE: 425-261-6282 FILE: SCALE: 1:100 TAX DISTRICT: DWG 1 OF 1 TWNSHP: 27N RING: 3E SEC:23 SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM LEGEND: OS SIGNALIZED INTERSECTION OCONE (CANDLESTICK) TYPE III BARRICADE WORKTRUCK WORK ZONE LIMITS OWE WARNING SIGN ARROW BOARD REQUIRED) (WHERE DIRECTION OF TRAFFIC (NOT PAVEMENT MARKINGS) FLAGGER-SPOTTER FLAGGER STATION ALLEY ATCO COMMUNICATIONS SERVICES, LLC AS THE DESIGNER OF THIS TRAFFIC CONTROL PLAN, MAKES NO REPRESENTATION AS TO ITS' GENERAL ADEQUACY OR BEING APPROVED FOR IMPLEMENTATION. APPROVAL MUST RESULT FROM THE TRAFFIC ENGINEER OR OTHER PUBLIC OFFICIAL HAVING STATUTORY ENFORCEMENT AUTHORITY IN THE JURISDICTION. UTILIZATION AND IMPLEMENTATION OF THIS PLAN SHALL BE A RESULT OF THE APPROVAL. REF. MUTCD 2009 6A - 01 (10) C❑NSTRUCTI❑N TO PLACE NO PARKING SIGNS 72 HOURS PRI❑R TO START WORK RECEIVED SIGN LEGEND: NOV 08 2023 ROAD SHOULDER CITY OF EDMONDS WORK> < WORK DEVELOPMENT AHEAD SERVICES DEPARTMENT W21-5 AR-217 4 EDMONDS ST x w20-1� X (25 MPH) POLE C WORK AR-217 AREA 8 DRIVEWF ENGINEERING DIVISION APPROVED AS NOTED .1111 12/04/2023 Vill PHASE 1 WORK DETAILS: REMOVE CABLE FROM A POLE LOCATED AT THE ALLEY BETWEEN 2ND AVE N AND 3RD AVE N WEST TO POLE C. REMOVE POLE C AND PLACE A 17X30 HH WHERE POLE C WAS REMOVED. SPOTTER NEEDED FOR PEDESTRIAN TRAFFIC AND DRIVEWAY ACCESS. TRAFFIC CONTROL INSPECTION SHALL BE 2ND AVE N REQUIRED WHENEVER WORK ZONE IS SET UP (25 MPH) n r r �lY SHOULDER W20- CLOSURE (L/3) X l W20-1� X W21- POLE D WORK WORK AREA X AREA POLE AR 217 �4 W20-1 v w a. b4 ALLEY BUFFER AREA LONGITUDINAL BUFFER SPACE = B POSTED SPEED (MPH) 25 30 35 40 45 50 55 60 64 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DEVICE = R HOST VEHICLE WEIGHT (Ibs) 9,900 TO 22,000 HOST VEHICLE WEIGHT (Ibs) > 22,000 < 45 MPH 45 - 55 MPH > 55 MPH < 45 MPH 45 - 55 MPH > 55 MPH 100, 123' 172' 74' 100, 150' 2ND AVE N (25 MPH) NOTE: MON. - FRI. = 7:00am TO 4:00pm a ]EWALK SIDEWALK EDMONDS ST (25 MPH) W20-1 b4 ALLEY CHANNELIZATION DEVICE SPACING (feet) MPH TAPER TANGENT 50/70 40 80 35/45 30 60 25/30 20 40 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER POSTED SPEED (MPH) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 8 40 40 60 90 120 130 150 160 170 190 10 40 60 90 90 150 170 190 220 220 240 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THAN 8' 3RD AVE N (25 MPH) `W20-1 {` ­)EWALK 0 a EE -=> EEE `1 a w n owl ut 3RD AVE N SIGN SPACING = X (1) FREEWAY & EXPRESSWAYS 55 / 70 MPH 1500' ± RURAL HIGHWAYS 60 / 65 MPH 800' ± RURAL ROADS 45 / 55 MPH 500' ± RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' ± RURAL ROADS & URBAN ARTERIALS 25 / 30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200' ± (2) URBAN STREETS 25 MPH OR LESS 100'± (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS (2) THIS SPACE MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. O ATCO COMMUNICATIONS SERVICES, LLC Www.atcctelecom.com 360.563.9000 708 First Street Snohomish, WA 98290 ziPylfiber Everett, WA 98206 � Qui ~ � J 3 Lo Lo 0wm Z J Z a U U) H v LU z LU p z 0 o � > Q u W W U) z 0 'IT �— z 0 U U W U.1 LL m z � U Q U Z O LLI z of D- � a- U O LL DATE: 10.20.2023 REVIEWED BY: M. BERNERT WSTCS# ES2 000313 DESIGNED BY: M. COMER ATCO CONTACT: 830.329.1982 michael.comer*atcotelecom.com SCALE: SHEET: =5C 02 N0: 2OF6 SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM LEGEND: OS SIGNALIZED INTERSECTION OCONE (CANDLESTICK) TYPE III BARRICADE WORKTRUCK WORK ZONE LIMITS OWE WARNING SIGN ARROW BOARD REQUIRED) (WHERE DIRECTION OF TRAFFIC (NOT PAVEMENT MARKINGS) FLAGGER-SPOTTER FLAGGER STATION SIGN LEGEND: ROAD BE WORK SHOULDER BE AHEAD WORK TO STOP W20-1 W21-5 W20-713 ATCO COMMUNICATIONS SERVICES, LLC AS THE DESIGNER OF THIS TRAFFIC CONTROL PLAN, MAKES NO REPRESENTATION AS TO ITS' GENERAL ADEQUACY OR BEING APPROVED FOR IMPLEMENTATION. APPROVAL MUST RESULT FROM THE TRAFFIC ENGINEER OR OTHER PUBLIC OFFICIAL HAVING STATUTORY ENFORCEMENT AUTHORITY IN THE JURISDICTION. UTILIZATION AND IMPLEMENTATION OF THIS PLAN SHALL BE A RESULT OF THE APPROVAL. REF. MUTCD 2009 6A - 01 (10) W20-7A BUFFER AREA LONGITUDINAL BUFFER SPACE = B POSTED SPEED (MPH) 25 30 35 40 45 50 55 60 64 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DEVICE = R HOST VEHICLE WEIGHT (Ibs) 9,900 TO 22,000 HOST VEHICLE WEIGHT (Ibs) > 22,000 < 45 MPH 45 - 55 MPH > 55 MPH < 45 MPH 45 - 55 MPH > 55 MPH 100, 123' 172' 74' 100, 150' TRAFFIC HALT NO MORE THEN 5 MIN, ACROSS (STREET) TO ALLOW AERIAL CR❑SSING EDMONDS ST (25 MPH) 1 AR-217 W20-1/T DRIVEWAY N 1 POLE C WI / WORK ARI A _—POLE B 7A 7B qLo b4 �= X X W21 W20-7A. rW20- 0 PHASE 2 WORK DETAILS: REMOVE CABLE FROM POLE C TO POLE B, PULL CABLE FROM NEW 17X30 HH THROUGH EXISTING 2' C❑NDUIT TO POLE B AND RISER UP. o w SPOTTER NEEDED FOR PEDESTRIAN TRAFFIC AND DRIVEWAY ACCESS. SIDEWALK EDMONDS ST y (25 MPH) RAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP I ENGINEERING DIVISION APPROVED AS NOTED jilt "j j,.,,,nQ 12/04/2023 VV NOTE: MON. - FRI. = 7:00am TO 4:00pm CHANNELIZATION DEVICE SPACING (feet) MPH TAPER TANGENT 50/70 40 80 35/45 30 60 25 / 30 20 40 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER POSTED SPEED (MPH) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 8 40 40 60 90 120 130 150 160 170 190 10 40 60 90 90 150 170 190 220 220 240 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THAN 8' RECEIVED NOV 08 2023 T CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SIGN SPACING = X (1) FREEWAY & EXPRESSWAYS 55 / 70 MPH 1500' ± RURAL HIGHWAYS 60 / 65 MPH 800' ± RURAL ROADS 45 / 55 MPH 500' ± RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' ± RURAL ROADS & URBAN ARTERIALS 25 / 30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200' ± (2) URBAN STREETS 25 MPH OR LESS 100' ± (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS (2) THIS SPACE MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. O ATCO COMMUNICATIONS SERVICES, LLC www.atcoteiecom.com 360.563.9000 708 First Street Snohomish, WA 98290 ziPylfiber Everett, WA 98206 � <cn ~ � J 3 Do p z J wm Z a ° p U) H Q v LU Z w p z °Do o > < LU W � w z Z 0 'IT �— z 0 U W cn W 'U 1� LL m 7 � p Z U < U Z ° LLI Z of� CL a- °ILL ° LL DATE: 10.20.2023 REVIEWED BY: M. BERNERT WSTCS# ES2 000313 DESIGNED BY: M. COMER ATCO CONTACT: 830.329.1982 michael.comer*atcotelecom.com SCALE: SHEET: =5C 03 NO: 3OF6 SIGNALIZED INTERSECTION CONE (CANDLESTICK) TYPE III BARRICADE WORKTRUCK WORK ZONE LIMITS WARNING SIGN ARROW BOARD (WHERE REQUIRED) DIRECTION OF TRAFFIC (NOT PAVEMENT MARKINGS) FLAGGER-SPOTTER FLAGGER STATION ALLEY a� DRIVEWAY DRIVEWAY RECEIVED NOV 08 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ATCO COMMUNICATIONS SERVICES, LLC AS THE DESIGNER OF THIS TRAFFIC CONTROL PLAN, MAKES NO REPRESENTATION AS TO ITS' GENERAL ADEQUACY OR BEING APPROVED FOR IMPLEMENTATION. APPROVAL MUST RESULT FROM THE TRAFFIC ENGINEER OR OTHER PUBLIC OFFICIAL HAVING STATUTORY ENFORCEMENT AUTHORITY IN THE JURISDICTION. UTILIZATION AND IMPLEMENTATION OF THIS PLAN SHALL BE A RESULT OF THE APPROVAL. REF. MUTCD 2009 6A - 01 (10) SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM 11 R11-2--' SIGN LEGEND: ROAD ROAD WORK CLOSED ROAD CLOSED AHEAD AHEAD W20-1 W20-3 _j R11-2 �zu t TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP ALLEY I DRIVEWAY DRIVEWAY WORK AREA WORK AREA ALLEY I DRIVEWAY DRIVEWAY I DRIVEWAY PHASE 3 WORK DETAILS: Q OVER -LASH CABLE FROM SOUTH FROM POLE B CROSSING BELL ST, C❑NTINUE OVER -LASHING CABLE EAST ON THE SOUTH SIDE OF BELL ST TO A POLE AT AN ALLEY BETWEEN 3RD AVE N AND 4TH AVE N, THEN C❑NTINUE OVER -LASH NORTH ACROSS BELL ST UP THE ALLEY TO POLE E AND SPLICE CABLE, SPOTTER NEEDED FOR PEDESTRIAN TRAFFIC AND DRIVEWAY ACCESS, W20- W20- J"o ATCO COMMUNICATIONS SERVICES, LLC Www.atcctelecom.com 360.563.9000 708 First Street Snohomish, WA 98290 ziPylfiber Everett, WA 98206 Lo Lo ui 0wm Z J J Z a U t�j p U) Q H D D �o z DJ z o L0 r Q hT _ /1 w LLI J < z O `< o C/) y � �n m m a �t cM �— z ALLEY 0 _ -—Rll-2 I � WORK m POLE BAREA D N b4 D NOTIFY AFFECTED RESIDENTS, POLICE, FIRE DEPARTMENT, AND TRASH HAULERS A MINIMUM OF 24 HOURS PRIOR TO ALLEY CLOSURE. BUFFER AREA LONGITUDINAL BUFFER SPACE = B POSTED SPEED (MPH) 25 30 35 40 45 50 55 60 64 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DEVICE = R HOST VEHICLE WEIGHT (Ibs) 9,900 TO 22,000 HOST VEHICLE WEIGHT (Ibs) > 22,000 < 45 MPH 45 - 55 MPH > 55 MPH < 45 MPH 45 - 55 MPH > 55 MPH 100, 123' 172' 74' 100, 150' NOTE: MON. - FRI. = 7:00am TO 4:00pm CHANNELIZATION DEVICE SPACING (feet) MPH TAPER TANGENT 50/70 1 40 1 80 35/45 1 30 1 60 25/30 1 20 1 40 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER POSTED SPEED (MPH) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 8 40 40 60 90 120 130 150 160 170 190 10 40 60 90 90 150 170 190 220 220 240 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THAN 8' C 3 ENGINEERING DIVISION APPROVED AS NOTED ldl IN j jg, 4.g 12/04/2023 VV SIGN SPACING = X (1) FREEWAY & EXPRESSWAYS 55 / 70 MPH 1500' ± RURAL HIGHWAYS 60 / 65 MPH 800' ± RURAL ROADS 45 / 55 MPH 500' ± RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' ± RURAL ROADS & URBAN ARTERIALS 25 / 30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200' ± (2) URBAN STREETS 25 MPH OR LESS 100'± (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS (2) THIS SPACE MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. U ww co Z U Q U z O 6i Z ULU o o_ _j ILL DATE: 10.20.2023 REVIEWED BY: M. BERNERT WSTCS# ES2 000313 DESIGNED BY: M. COMER ATCO CONTACT: 830.329.1982 michael.comer*atcotelecom.com SCALE: SHEET: =5C 04 NO: 4 OF 6 SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM LEGEND: OS SIGNALIZED INTERSECTION OCONE (CANDLESTICK) TYPE III BARRICADE WORKTRUCK WORK ZONE LIMITS OWE WARNING SIGN ARROW BOARD REQUIRED) (WHERE DIRECTION OF TRAFFIC (NOT PAVEMENT MARKINGS) FLAGGER-SPOTTER FLAGGER STATION ATCO COMMUNICATIONS SERVICES, LLC AS THE DESIGNER OF THIS TRAFFIC CONTROL PLAN, MAKES NO REPRESENTATION AS TO ITS' GENERAL ADEQUACY OR BEING APPROVED FOR IMPLEMENTATION. APPROVAL MUST RESULT FROM THE TRAFFIC ENGINEER OR OTHER PUBLIC OFFICIAL HAVING STATUTORY ENFORCEMENT AUTHORITY IN THE JURISDICTION. UTILIZATION AND IMPLEMENTATION OF THIS PLAN SHALL BE A RESULT OF THE APPROVAL. REF. MUTCD 2009 6A - 01 (10) SIGN LEGEND: ROAD BE � WORK PREPARED AHEAD TO STOP W20-1 W20-713 W20-7A AR-217 TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP 3 W20-1 X W w x J X W20-7B a v4 wa X w20-7B a 4 / o w20-7A 3 2 BELL ST w20-7Al (25 MPH) -� ommmmmm PARK 8 n o 0 `W20- ENGINEERING DIVISION APPROVED AS NOTED — jell LVIL ""„p 12/04/2023 VV 4 ^W20-1 L AR-217 WORK AREA x IW20-7B 1 W a fW20-1 BUFFER AREA LONGITUDINAL BUFFER SPACE = B POSTED SPEED (MPH) 25 30 35 40 45 50 55 60 64 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DEVICE = R HOST VEHICLE WEIGHT (Ibs) 9,900 TO 22,000 HOST VEHICLE WEIGHT (Ibs) > 22,000 < 45 MPH 45 - 55 MPH > 55 MPH < 45 MPH 45 - 55 MPH > 55 MPH 100, 123' 172' 74' 100, 150' 1f W20-1/ SIDEWALK PARKING a 7 BELL ST (25 MPH) I 11 B I PHASE 3 WORK DETAILS: Q OVER —LASH CABLE FROM SOUTH FROM POLE B CROSSING BELL ST, C❑NTINUE OVER —LASHING CABLE EAST ON THE SOUTH SIDE OF BELL ST TO A POLE AT AN ALLEY BETWEEN 3RD AVE N AND 4TH AVE N, THEN C❑NTINUE OVER —LASH NORTH ACROSS BELL ST UP THE ALLEY TO POLE E AND SPLICE CABLE, SPOTTER NEEDED FOR PEDESTRIAN TRAFFIC AND DRIVEWAY ACCESS, TRAFFIC HALT NO MORE THEN S MIN, ACROSS (STREET) TO ALLOW AERIAL CROSSING X W I Lo X W20 7BJ cn w20-7AJ X X X�� �- wzo-7 w2o-7B w20- SIDEWALK PARKING a a WORK X AREA x 3 AREA 000 AR-217x BELL ST ^ W20-7A (25 MPH) U I X q Lo x `W20-76 � = W2o-76 /W20-1 CHANNELIZATION DEVIC� SPACING (feet) MPH TAPER TANGENT 50/70 40 80 35/45 30 60 25/30 20 40 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER POSTED SPEED (MPH) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 8 40 40 60 90 120 130 150 160 170 190 10 40 60 90 90 150 170 190 220 220 240 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THAN 8' NOTE: MON. - FRI. = 7:00am TO 4:00pm OT 0 `W20-1 w m w � RECEIVED L) L) o NOV 08 2023 ° LU ° o 0- a- J lW20-1 CITY OF EDMONDS / DEVELOPMENT SERVICES DEPARTMENT SIGN SPACING = X (1) FREEWAY & EXPRESSWAYS 55 / 70 MPH 1500' ± RURAL HIGHWAYS 60 / 65 MPH 800' ± RURAL ROADS 45 / 55 MPH 500' ± RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' ± RURAL ROADS & URBAN ARTERIALS 25 / 30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200' ± (2) URBAN STREETS 25 MPH OR LESS 100'± (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS (2) THIS SPACE MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. O ATCO COMMUNICATIONS SERVICES. LLC www.otcoteiecom.com 360.563.9000 708 First Street Snohomish, WA 98290 ziPylfiber Everett, WA 98206 J J Lo z m Z U U) Q v LU p <° Z Z o W O Lo Lo < W W co z O cz z O U U LL L� w I� g z LU J ILL DATE: 10.20.2023 REVIEWED BY: M. BERNERT WSTCS# ES2 000313 DESIGNED BY: M. COMER ATCO CONTACT: 830.329.1982 michael.comer*atcotelecom.com SCALE: SHEET: I"=7o� 05 NO: 5OF6 SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM LEGEND: ATCO COMMUNICATIONS SERVICES, LLC AS THE DESIGNER OF THIS TRAFFIC CONTROL PLAN, OS SIGNALIZED INTERSECTION MAKES NO REPRESENTATION AS TO ITS' GENERAL ADEQUACY OR BEING APPROVED FOR IMPLEMENTATION. PHASE APPROVAL MUST RESULT FROM THE TRAFFIC ENGINEER OR OTHER PUBLIC OFFICIAL HAVING STATUTORY CONE (CANDLESTICK) ENFORCEMENT AUTHORITY IN THE JURISDICTION. UTILIZATION AND IMPLEMENTATION OF THIS PLAN O SHALL BE A RESULT OF THE APPROVAL. REF. MUTCD 2009 6A - 01 (10) Al(\vim/ o TYPE III BARRICADE ATCO COMMUNICATIONS SERVICES, LLC w3 WORKTRUCK WORK DETAILS:60.563.9000 com SIGN LEGEND: 708 First Street WORK ZONE LIMITS 0 OVER —LASH CABLE FROM SOUTH FROM Snohomish, WA 98290 POLE B CR❑SSING BELL ST. C❑NTINUE OWE ❑VER—LASHING CABLE EAST ON THE �I I I I WARNING SIGN SOUTH SIDE OF BELL ST TO A POLE SHOULDER b e ROAD AT AN ALLEY BETWEEN 3RD AVE N ARROW BOARD WORK AND 4TH AVE N. THEN C❑NTINUE (WHERE REQUIRED) AHEAD WORK OVER —LASH NORTH ACROSS BELL ST DIRECTION OF C TO POLE E AND SPLICE CABLE, Everett, WA 98206 (NOT PAVVEMENTRAFF MARKINGS) w SPOTTER NEEDED FOR PEDESTRIAN � R, FLAGGER-SPOTTER W20-1 W21-5 AR-217 TRAFFIC AND DRIVEWAY ACCESS, Q 11 v � U) 3 J J Lo p uj mm Z a • FLAGGER STATION � 1-: ~ TRAFFIC CONTROL INSPECTION SHALL BE o c Q REQUIRED WHENEVER WORK ZONE IS SET UP w ° Z Z o w °Lo > Q DJ � w z z 0 BELL ST 4 X (25 MPH) x w2o-1 w20-1,"] � 'IT �— SIDE' z PARKING O PARKING 0 O O O O O PARKING SIDEWALK SIDEWALK WORK LL W20-1 W21-5 \AR-217 AREA BELL ST w U) L� POLE E (25 MPH) X X RECEIVED z Q z w ° ENGINEERING DIVISION NOV 08 2023 0 0 < ~ w 4 APPROVED AS NOTED a a LL jell tVl,,U,4z 12/04/2023 CITY OF EDMONDS VV DEVELOPMENT SERVICES DEPARTMENT BUFFER AREA LONGITUDINAL BUFFER SPACE = B POSTED SPEED (MPH) 25 30 35 40 45 50 55 60 64 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DEVICE = R 9,900 TO 22,000 > 22,000 < 45 MPH 45 - 55 MPH > 55 MPH < 45 MPH 45 - 55 MPH > 55 MPH NOTE: MON. - FRI. = 7:00am TO 4:00pm CHANNELIZATION DEVICE SPACING (feet) MPH TAPER TANGENT 50/70 40 80 35/45 30 60 25 / 30 20 40 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER POSTED SPEED (MPH) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 8 40 40 60 90 120 130 150 160 170 190 10 40 60 90 90 150 170 190 220 220 240 SIGN SPACING = X (1) FREEWAY &EXPRESSWAYS 55 / 70 MPH 1500' ± RURAL HIGHWAYS 60 / 65 MPH S00' ± RURAL ROADS 45 / 55 MPH 500' ± RURAL ROADS &URBAN ARTERIALS 35 / 40 MPH 350' ± RURAL ROADS &URBAN ARTERIALS 25 / 30 MPH RESIDENTIAL &BUSINESS DISTRICTS 200' ± (2) DATE: 10.20.2023 REVIEWED BY: M. BERNERT WSTCS# ES2 000313 DESIGNED BY: M. COMER ATCO CONTACT: $30.329.1982 michael.comerC�?atcotelecom.com SCALE: SHEET: =5� 06 N0: 60F6 Edmonds ATCO COMMUNICATIONS SERVICES, LLC AS THE DESIGNER OF THIS TRAFFIC CONTROL PLAN, MAKES NO REPRESENTATION AS TO ITS' GENERAL ADEQUACY OR BEING APPROVED FOR IMPLEMENTATION. APPROVAL MUST RESULT FROM THE TRAFFIC ENGINEER OR OTHER PUBLIC OFFICIAL HAVING STATUTORY ENFORCEMENT AUTHORITY IN THE JURISDICTION. UTILIZATION AND IMPLEMENTATION OF THIS PLAN SHALL BE A RESULT OF THE APPROVAL. REF. MUTCD 2009 6A - 01 (10) Brackett's Landing Shoreline Sanctuary,,, &.,Irlset Beac:'i19 4W OW Edmonds Ferry Teri y Cascadia Art M i W Dayton St ; Dayton St r_s " x: =a Q' r..". Al Cha Way U� G3rofway g Community Christian Fellowship 0IEn S Edmonds Center .. For the Arts T3 : .0,1a - Della Sou[ Hair Design Daley St r Salt and Iroli f'] Sprague St WORK AREA Edmonds Police Lq Department Bell St -40'es st MARKET Edmonds 91---qo Dayton St w VICINITY MAP Dayton St -► CJ+ z Holy Rost Holy Rosary t 9ja6k,a 9 Holy Trim D2 3 rD Z SP Ed 3 Be n Molly Moon's Ice Cream Fra 19 Edmonds Library - Sno-Isle Libraries Edmonds Library' OVA > RECEIVED NOV 08 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O ATCO COMMUNICATIONSSERVICES. LLC www.atcotelecom.com 360.563.9000 708 First Street Snohomish, WA 98290 ziPIy fiber Everett, WA 98206 a U) J 3 J � L p w a LO Z m 0 U o W � z w LO 0 Q LU U) �J z III co U ) I� 0 U mLI L lY Z U a U Z O W 2 w w F- a Z O a. O CL U o J LL DATE: 10.20.2023 REVIEWED BY: M. BERNERT WSTCS# ES2 000313 DESIGNED BY: M. COMER ATCO CONTACT: 830.329.1982 michael.comer@atcotelecom.com SCALE: SHEET: NOT TO U SCALE NO: 1 OF 6 RECEIVED CITY OF EDMONDS Right -of -Way Application #1393975 - 5501164 NOV 08 2023 MyBuildingPermil:.com CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Applicant First Name Last Name Company Name Arianne Mommsen Ziply Fiber Number Street Apartment or Suite Number E-mail Address 426 E Casino Road grpatcopermits@ziplyfiber.com City State Zip Phone Number Extension Everett WA 98208 (402) 670-8384 Contractor Company Name ZIPLY FIBER NORTHWEST LLC Number Street Apartment or Suite Number 426 E Casino Rd City State Zip Phone Number Extension Everett WA 98208 (425) 231-3928 State License Number License Expiration Date UBI # E-mail Address ZIPLYFN782L3 5/25/2024 iyini i4g6 caitlin.reid@ziply.com Project Location Number Street Floor Number Suite or Room Number 115 EDMONDS ST City Zip Code County Parcel Number EDMONDS 98020 27032300101700 Associated Building Permit Number Tenant Name Additional Information (i.e. equipment location or special instructions)_ Work Location Property Owner First Name Last Name or Company Name CHRISTOPHILIS KONSTANTINOS Number Street Apartment or Suite Number 155 Edmonds St City State Zip EDMONDS WA 98020 Certification Statement - The applicant states: I certify that I am the owner of this property or the owner's authorized agent. If acting as an authorized agent, I further certify that I have full power and authority to file this application and to perform, on behalf of the owner, all acts required to enable the jurisdiction to process and review such application. I have furnished true and correct information. I will comply with all provisions of law and ordinance governing this type of application. If the scope of work requires a licensed contractor to perform the work, the information will be provided prior to permit issuance. Date Submitted: 11/7/2023 Submitted By: Arianne Mommsen Page 1 of 2 CITY OF EDMONDS MyBuildingPermit.com Right -of -Way Application #1393975 - 5501164 Project Contact Company Name: Ziply Fiber Northwest, LLC Name: Arianne Mommsen Email: grpatcopermits@ziplyfiber.com Address: 426 E Casoni Rd Phone #: (402) 670-8384 Everett wa 98208 Project Type Activity Type Scope of Work Utility Purveyor Utility Work Disturbance of Surface Project Name: 5501164 Description of Remove Cable. Pull Cable through existing conduit from HH where pole C was removed. Work: Riser Up pole B and over lash south and east to Pole E located on the north side of Bell ST at an alley between 3rd Ave N and 4th Ave N. Project Details Project Information Job Number 5501164 Page 2 of 2