Loading...
BLD2023-0674_Manufacturer_Specifications_and_Installation_Instructions_6.2.2023_8.06.27_AM_3583240Job Name: System Reference: Date: FEATURES • Variable speed INVERTER -driven compressor • ENERGY STAR® certified • M-NET connection through outdoor unit • Quiet outdoor unit operation as low as 50 dB(A) • Intelligent Power Module (IPM) for reduced power loss • Selectable thermal lockout/restart function • Optional base pan heater • High pressure switch for additional protection • Thermal differential of +/-1 ° F from setpoint ENERGY STAR products are third -party certified by an EPA -recognized Certification Body. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling' (Non -Ducted H Mix // Ducted) Maximum Capacity BTU/H 2O,000 H 20,000 H 20,000 Rated Capacity BTU/H 18,000 // 19,000 H 20,000 Minimum Capacity BTU/H W 5,700 H 5,700 // 5,700 2,245 H 2,245 // 2,245 Maximum Power Input Rated Power Input W % 1,417 // 1,709 H 2,000 98.8, 98.8 H 98.8, 98.8 H 98.8, 98.8 Power Factor (208V, 230V) Heating at 47°F2 (Non -Ducted H Mix H Ducted) Maximum Capacity BTU/H 25,500 H 25,500 H 25,500 Rated Capacity BTU/H 22,000 H 22,000 H 22,000 Minimum Capacity BTU/H 7,400 H 7,400 H 7,400 Maximum Power Input W 2,455 H 2,455 // 2,455 Rated Power Input W 1,641 H 1,706 // 1,771 Power Factor (208V, 230V) % 98.6, 98.6 H 98.6, 98.6 H 98.6, 98.6 Heating at 17°F3 (Non -Ducted H Mix // Ducted) Maximum Capacity BTU/H 15,500 // 15,000 H 14,500 Rated Capacity BTU/H 12,500 // 13,000 H 13,500 Maximum Power Input W 1,750 // 1,780 H 1,810 Rated Power Input W 1,300 // 1,325 H 1,350 Heating at 5°F4 (Non -Ducted // Mix H Ducted) Maximum Capacity BTU/H 11,100 // 11,000 H 10,900 Maximum Power Input W 1,600 // 1,650 H 1,700 Efficiency (Non -Ducted H Mix // Ducted) SEER I SEER2 20.0 H 18.0 H 16.0120.0 // - H - EER1IEER21 12.7H11.35H10.0112.7H-H- HSPF (IV) I HSPF2 (IV) 10.0 H 9.65 // 9.3 19.3 H - H - COP at 47°F2 3.93 H 3.78 H 3.64 COP at 17°F at Maximum Capacity3 2.6 H 2.47 H 2.35 COP at 5°F at Maximum Capacity' 2.03 H 1.96 // 1.88 ENERGY STAR® Certified Yes H No H No Electrical Electrical Power Requirements Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187-253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size A 20 Recommended Wire Size AWG 14 Minimum Circuit Ampacity A 17.2 Maximum Overcurrent Protection A 20 Fan Motor Full Load Amperage A 1.77 Outdoor unit Airflow Rate (Cooling / Heating) CFM 1,342 / 1,458 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling' dB(A) 50 Sound Pressure Level, Heating' dB(A) 54 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model SNB140FQUH2T Compressor Rated Load Amps A 10.7 Compressor Locked Rotor Amps A 15.5 Compressor Oil Type H Charge oz. NEO22 H 20.3 Base Pan Heater Optional Unit Dimensions W: In. [mm] 33-1/16 [840] D: In. [mm] 13 [330] H: In. [mm] 27-15/16 [710] Package Dimensions W: In. [mm] 39-3/4 [1,010] D: In. [mm] 18-1/2 [470] H: In. [mm] 33-1/2 [850] Unit Weight Lbs.[kg] 126 [57] Package Weight Lbs.[kg] 147 [67] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum'") °FDB 115 / 14 Cooling Thermal Lock -out / Re -start Temperatures °FDB 10.4 / 14 Heating Intake Air Temp (Maximum / Minimum) °FWB 65 / 5 Heating Thermal Lock -out / Re -start Temperatures °FDB 1.415 Refrigerant Charge Lbs, oz 5.0, 15.0 Chargeless Piping Length Ft. [m] 98.0 [30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.216 [20] NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) OF 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 'A 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130 % , the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Indoor unit connection Maximum Number of Connected IDU Minimum Number of Connected IDU Minimum connected capacity Maximum connected capacity BTU/H BTU/H 2 2 12,000 24,000 Piping Liquid Pipe Size O.D. (Flared) Gas Pipe Size O.D. (Flared) Total Piping Length Maximum Height Difference, ODU above IDU Maximum Height Difference, ODU below IDU Farthest Piping Length from ODU to IDU Maximum Number of Bends for IDU In.[mm] A,B: 1/4 [A,B: 6.35] In.[mm] A,B: 3/8 [A,B: 9.52] Ft. [m] 164 [50] Ft. [m] 33 [10] Ft. [m] 49 [15] Ft. [m] 82 [25] 50 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) (Rated data is determined at a fixed compressor speed) 21-leating at 47°F (Indoor // Outdoor) 31-leating at 17°F (Indoor // Outdoor) Conditions 41-leating at 5°F (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB °F 70 DB, 60 WB // 47 DB, 43 WB °F 70 DB, 60 WB // 17 DB, 15 WB °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions I5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130 % , the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Air Outlet Guide Refrigeration Ball Valve - 1/2" ❑ MAC-856SG ❑ BV12FFS12 Refrigeration Ball Valve - 1/4" ❑ BV14FFSI2 Ball Valve Refrigeration Ball Valve - 3/8" ❑ BV38FFSI2 Refrigeration Ball Valve - 5/8" ❑ BV58FFSI2 M-Net Control Wire, 1,000' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-1000 Control Wire M-Net Control Wire, 250' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-250 Drain Socket Drain Socket ❑ MAC-811 DS Hail Guards Hail Guard ❑ HG-A8 M-NET Converter M-NET Converter ❑ PAC-IF01 MNT-E 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S144-250 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW144-250 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S144-50 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW144-50 Mini -Split Wire 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S164-250 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW164-50 Condensing Unit Mounting Pad: 16" x 36" x 3" ❑ ULTRILITEI Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Optional Defrost Heater Base Heater ❑ PAC-646BH-E Adaptor: 1/2" x 3/8" ❑ MAC-A455JP-E Adaptor: 1/2" x 5/8" ❑ MAC-A456JP-E Port Adapter Adaptor: 3/8" x 1/2" ❑ MAC-A454JP-E Adaptor: 3/8" x 5/8" ❑ PAC-SG76RJ-E 18" Single Fan Stand ❑ QSMS1801 M 24" Single Fan Stand ❑ QSMS2401 M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish ❑ QSWBSS Outdoor Unit Stand —12" High ❑ QSMS1201 M Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Handle FORM# MXZ-2C20NA3 - 202206 1.FREE SPACE E O E E O 3-15/16" or more p � 8 7777T 3-15/16' or more. _ 13-25/32" or more 2.SERVICE SPACE SERVICE SPACE Unit: inch (mm) LIG 111"I.1.35)FLARE GAS 3l8-(e9.52)FIARE unding terminal Conadult k nul Connector 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com C US Intertek Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.