Loading...
Building PermitType: RESIDENTIAL BLDG Subtype: ADDITION I Status: ISSUED Parcel No: 00564900401600 Subdivision: 005649, 004491 Fire Sprinklers: Valuation: $150,000.00 Code Edition: 0 Site Address: 10533 243RD PL SW EDMONDS,WA 98020-5793 Lot: 0 Lot Area: Zoning: Occupancy Type: Construction Type: No. Stories: 0 # of Dwelling Units: 0 Scope of Work: KEAN- ADDITION & REMODEL M INCL P SEP Applied: 7/20/2023 Issued:12/14/2023 Final: Expiration Date: 12/8/2024 Issued by: NED I WA State Contractor L & I #: VANDER*811RD I CONTACTS NAME TYPE NAME ADDRESS PHONE EMAIL APPLICANT PHILLIP DEHENNIS 10016 EDMONDS WAY C229, (425)599-5381 PHILLIP@WALLSANDWEEDS.COM EDMONDS WA 98020 CONTACT WALLS AND WEEDS, INC. 10016 EDMONDS WAY C229, (425)599-5381 phillip@wallsandweeds.com EDMONDS WA 98020 CONTRACTOR VANDERBEKEN REMODEL 306 STATE AVE, MARYSVILLE (425)870-8123 ron@vanderbeken-remodel.com WA 98270 34699 N SHORE DR, MOUNT OWNER KIMBERLY C KEAN VERNON WA 98274-8219 •- • DESCRIPTION 7ACR ACCOUNT AMOUNT PAID PAID DATE RECEIPT # HEAT PU MP - 1.75 BTU OR 001.000.345.83.000.00 00.00$57.00 $57.00 12/13/23 R33274 LESS APPLIANCE VENT 001.000.345.83.000.00 $17.00 $17.00 12/13/23 R33274 BLD - RES VALUE BASED FEE 001.000.345.83.000.00 $1,400.00 $1,400.00 12/13/23 R33274 BLD - RES VALUE BASED REVIEW 001.000.345.83.000.00 $1,190.00 $1,190.00 8/16/23 R30760 CITY TECHNOLOGY FEE - PER 001.000.321.99.100.00 $45.00 $45.00 8/16/23 R30760 PERMIT ENG - INSPECTIONS 001.000.345.83.400.00 $252.00 $252.00 12/13/23 R33274 FAN CONNECTED TO A SINGLE 001.000.345.83.000.00 $51.00 $51.00 12/13/23 R33274 DUCT GAS PIPING - NEW OR RELOCATED 001.000.345.83.000.00 $34.00 $34.00 12/13/23 R33274 MECHANICAL BASE PERMIT FEE 001.000.322.10.000.00 $57.00 $57.00 12/13/23 R33274 STATE BUILDING CODE SURCHARGE 001.000.237.150 $6.50 $6.50 12/13/23 R33274 RES TOTALS: $3,109.50 $3,109.50 • 1 • CONDITION TYPE STATUS NOTES Printed: Thursday, December 14, 2023 8:13:35 AM 1 of 4 'RESIDENTIAL BLDG PermitCity - • • • • EL 98020 1 1 • 1 www.edmondswa.gov• 1- HOLD HARMLESS - Applicant on behalf of his or her spouse heirs assigns and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance of this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. 2 - PERMIT DISCLOSURE - Any request for alternate design, modification, variance or other administrative deviation from adopted codes ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such requests shall be established by Council and shall be paid upon submittal and are nonrefundable. 3- SOUND OR NOISE - Sound/Noise originating from temporary construction sites as a ALL BUILDING PERMITS FOR result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only INFORMATION during the hours of 7:OOam to 6:OOpm on weekdays and 10:OOam to 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. 4 - OCCUPANCY - Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. 5 - PLUMBING - Plumbing contractor license laws are regulated by Chapter 18.106 RCW. Property owners who hire an unlicensed plumber may assume the risks and potential monetary liability for work performed by unlicensed plumbing contractors. For more information contact L&I Department of Licensing at 1-800-647-0982. CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND ON EACH LEVEL IN FOR CARBON MONOXIDE SYSTEMS NEW CONSTRUCTION AND IN EXISTING DWELLINGS WHEN ALTERATIONS, REPAIRS OR INFORMATION ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED. It is the owner's responsibility to repair/replace all damage of utilities or frontage DAMAGE TO FRONTAGE FOR improvements in City right of Ways or Easements to City Standards caused by or IMPROVEMENTS INFORMATION occurring during the permitted project. ELECTRICAL PERMIT FOR Obtain Electrical Permit from State Department of Labor and Industries 425-290-1309. NFORMATION FOR MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS INFORMATION REQUIREMENTS. Approval of this foundation design is conditional subject to inspection of existing site soil FOR conditions. Retaining walls must be designed and constructed to resist the lateral FOUNDATION BEARING INFORMATION pressure of the retained material. Provisions must be made for the control and drainage of surface water around buildings. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its FOR officials, employees, and agents from any and all claims for damages of whatever nature, HOLD HARMLESS INFORMATION arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. FOR SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS INFORMATION www.mybuildingpermit.com Installation, use and maintenance of equipment and components shall be per MANUFACTURER SPECS FOR manufacturers specifications, installation instructions, and applicable state codes. INFORMATION Provide manufactures installation instructions on site for Building Inspector. The issuance of this permit in no way constitutes approval from any other agencies REGULATING AGENCIES FOR having regulatory authority over the facility and this construction activity. It is the INFORMATION responsibility of the property owner to obtain any and all such required approvals. Printed: Thursday, December 14, 2023 8:13:35 AM 2 of 4 'RESIDENTIAL BLDG PermitCity PERMIT NUM •Edmonds www.edmondswa.gov Special Inspection for REQUIRED SPECIAL FOR INSPECTIONS INFORMATION 1. Adhesive Anchors FOR Heat pumps, AC units and similar equipment greater than 36 inches in height are not SIDE YARD EQUIPMENT INFORMATION allowed within required building setbacks. Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of FOR 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding SOUND AND NOISE INFORMATION Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of FOR 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding SOUND AND NOISE INFORMATION Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. Special inspections have been called for on this project and are noted on the approved SPECIAL INSPECTION BUILDING FOR construction plans. It is the owner and or contractors responsibility to ensure that reports DIVISION INFORMATION are provided to the City on a weekly basis. SPECIAL INSPECTION REPORTS FOR Submit all special inspection reports to the City Building Official on a weekly basis. NFORMATION FOR All utilities shall be located prior to any excavation. New locates shall be called for if at UTILITY LOCATES INFORMATION time of excavation, original locates are no longer identifiable. Installer shall provide the manufacturer installation, operating instructions, and a whole WHOLE HOUSE FAN FOR house ventilation system operation description. A label shall be affixed to the whole INFORMATION house timer control that reads "Whole house ventilation, see operating instructions". INSPECTIONTYPE INSPECTOR COMPLETED RESULT NOTES A-1 BUILDING PRECON B-1 SETBACKS B-2 FOOTINGS B-2 FOUNDATION WALL B-3 EXT WALL SHEATHING B-3 MECH ROUGH IN B-3 ROOF SHEATHING B-3 UNDERFLR FRAMING B-4 FRAMING B-4 INTERIOR SHEAR B-4 SHOWER PAN B-5 INSULATION ENERGY B-7 BUILDING OTHER INSP X-3 BUILDING FINAL" Printed: Thursday, December 14, 2023 8:13:35 AM 3 of 4 'RESIDENTIAL BLDG PermitCity - • • • • 98020 1 1 • 1 . •. • B-5 BLDG SPECIAL Special Inspection for INSPECTION 1. Adhesive Anchors A-1 TESC AND MOBILIZE E-3 STRM TIGHTLINE E-9 COMPOST AMEND E-3 STRM FOOTING DRAIN Note to Inspector: Per architect and building department, footing drains are not required a this time. X-2 ENGINEERING FINAL Note to Inspector: Make sure driveway is widened to allow for 2 parking stalls. The widening shall occur on private property and landscape placed between the property line and the widening portion of the driveway to prevent vehicles from driving over landscape areas. Printed: Thursday, December 14, 2023 8:13:35 AM 4 of 4