Loading...
BLD2023-1625_Other_12.20.2023_8.42.38_AM_3963201FEEDER SCHEDULE TOTAL MODULE(S) O ENPHASE Q CABLES + #6 BARE EGC IN OPEN AIR (4) #12 THWN-2 +(1) #10 GND IN 3/4" EMT TOTAL DC POWER 9.02kW Vmpp ® NOT USED OPERATING VOLTAGE 240V impp (2) #8 THWN-2 + (1) #8 THWN-2 NEUT + (1) #10 GND IN 1" EMT Voc ® NOT USED MAX AC POWER OUT 6.38kVA Isc ®(2)#6THWN-2+(1)#6THWN-2NEUT+(1)#6GECIN1"PVC Voc TEMP COEFF-0.279%/°C CURRENT CARRYING CONDUCTORS O NOT USED - o Fr -NOT -USED PUGET SOUND SOLAR FLAG NOTES: 805 Rainier Ave S MAIN BONDING JUMPER, LINE SIDE TAP BEFORE MAIN BREAKER IN COMPLIANCE WITH NEC 2020 705.11 Seattle, WA 98144 OMNI CABLE FOR MONITORING DEVICE, IN FEEDER PIPE #3 Tel: 206-706-1931 THE ADDITIONAL SUPPLY SIDE SOURCE DISCONNECTING MEANS FOR THE PV SYSTEM WILL BE GROUPED WITH THE SERVICE DISCONNECTING MEANS FOR THE STRUCTURE PER " x WCEC 705.11 � o ioa NEW 40A WALLBOX EV CHARGER 3 N a (2) #8 THWN-2 + (1) #8 THWN-2 NEUT + (1) #10 GND IN 1" EMT s K �o 1.8 DAYS i o00 z~> LEGEND � N oio GROUNDING w co Y � doh BREAKER 0 SOLAR MODULE J O -1m o QOD ❑J JUNCTION BOX Z c0 -Np 0 o a co zy O PRODUCTION Q � E 1.1 i METER c) -O W OM NET METER (� o g cc �dw ®FUSED AC G o m c DISCONNECT - UNFUSED AC o a DISCONNECT o MI MICROINVERTER ,z R + DC OPTIMIZER no o o 3u 70A AC UTILITY Mo. IQ COMBINER DISCONNECT �� SERVICE 40A J 125A LOAD 0 PRFIJMINARYDESIGN 11/30/23 20A z� CENTER REV DESCRIPTION DATE 125A MAIN DRAWN BY NN 20A o 125A BUS CHECKED BY BU 50A 15A ®% PROJECT #: 21261 O SALES: JAKE SHIELDS M� M� STRING OF O PM: BILL ULSUND 11 MODULES PM CELL: (253) 951-0385 3 GATEWAY IQ ELECTRICAL ONE LINE M� M� STRING OF � � DIAGRAM 11 MODULES l ROOF EXTERIOR INTERIOR EXISTING PV-102 STRING MAX AC CONTINUOUS OUTPUT 13.31A SYSTEM 22 CONTINUOUS OUTPUT 26.62A STRING MAX MICROS 11 MICROINVERTER TOTAL PV STRING SIZING DETAILS SYSTEM MAX AC MODULE DATA MODULE MODEL SILFAB SIL-410-BG 38.07V 10.77A 45.92V 11.30A INVERTER MODEL ENPHASE IQ8PLUS-72-2-US MAX DC IN 60V MAX CURRENT OUT 1.21A MIN DESIGN TEMP -40°C INVERTER DATA MAX CURRENT IN 15A MAX AC OUT 290VA CONDUIT CURRENT CALCULATIONS #12 THWN-2 ALLOWABLE CURRENT 30 4 ADJUSTMENT FACTOR 80% ADJUSTED ALLOWED CURRENT 24A STRING MAX AC OUTPUT CURRENT 13 .3A OVERCURRENT PROTECTION PV TOTAL 33.3A 40A MAX AC OUTPUT 125 % SAFETY OCPD SIZE PV STRING MAX 16.6A 20A ° ° SOLAR PV SYSTEM DETAILS 22 MODULE DATA MODULE MODEL SILFAB SIL-410-BG 38.07V 10.77A 45.92V 11.30A INVERTER MODEL ENPHASE IQ8PLUS-72-2-US MAX DC IN 60V MAX CURRENT OUT 1.21A MIN DESIGN TEMP -40°C INVERTER DATA MAX CURRENT IN 15A MAX AC OUT 290VA CONDUIT CURRENT CALCULATIONS #12 THWN-2 ALLOWABLE CURRENT 30 4 ADJUSTMENT FACTOR 80% ADJUSTED ALLOWED CURRENT 24A STRING MAX AC OUTPUT CURRENT 13 .3A OVERCURRENT PROTECTION PV TOTAL 33.3A 40A MAX AC OUTPUT 125 % SAFETY OCPD SIZE PV STRING MAX 16.6A 20A ° ° SOLAR PV SYSTEM DETAILS 22 CONDUIT CURRENT CALCULATIONS #12 THWN-2 ALLOWABLE CURRENT 30 4 ADJUSTMENT FACTOR 80% ADJUSTED ALLOWED CURRENT 24A STRING MAX AC OUTPUT CURRENT 13 .3A OVERCURRENT PROTECTION PV TOTAL 33.3A 40A MAX AC OUTPUT 125 % SAFETY OCPD SIZE PV STRING MAX 16.6A 20A ° ° SOLAR PV SYSTEM DETAILS 22 OVERCURRENT PROTECTION PV TOTAL 33.3A 40A MAX AC OUTPUT 125 % SAFETY OCPD SIZE PV STRING MAX 16.6A 20A ° ° SOLAR PV SYSTEM DETAILS 22 SOLAR PV SYSTEM DETAILS 22 SUPPLY CALCULATIONS