20210191E002 Stark Residence Foundation Repairs 2022-12-27 FR 017FIELD REPORT 8A I Associated Earth Sciences Kirkland I Tacoma I Mount Vernon 42S-827-7701 1 www.aesgeo.com Date Project Name Project No. Report No. 12/27/2022 Stark Residence Foundation Repairs 20210191EO02 017 Location Municipality AESI Project Manager AESI Field Rep 133 Sunset Ave N City of Edmonds Stephen Siebert, P.E. Devon Nutter Permit No. Client/Owner Attn Requested By BLD2022-0463 Susan Stark Client Contractor Engineer/Architect Pile Contractor Weather General Contractor CG Engineering NA Advanced Foundation 40s, rainy Supports LLC. /Evan THE FOLLOWING WAS NOTED: Helical Piles: AESI was onsite today at 10:00am, as requested by the contractor to observe and document helical pile installation. Today, the contractor set up and installed piles H4 and HS (see Figure 1). See Table 1 for helical pile installation details. The helical piles appeared to be installed to minimum specifications, per plan. Work finished around 1:30PM, and AESI plans to return the following day to observe installation of the pipe piles specified in the revised plans (see Figure 2). Table 1: Helical Pile Installation Details Helical Depth measured PSI range during Design Min -Max Install Torque (ft- Comments Anchor from bottom of installation. Load Ibs) 3,100-5,500 per design Pile # footing Ending psi (kips) achieved? H5 22' 1200-1800, 14 5,595 Lead section 7', then 5'-long 1,800 sections H4 23.5' 1000-1600, 14 4,973 Lead section 7', then 5'-long 1,600 sections Date Mailed: Principal / PM: Stephen Siebert, P.E. 4/k? v.2.20 This document is considered a DRAFT until signed or initialed by on AESI Principal or Project Manager Page 1 of 3 FIELD REPORT 8A S1 Associated Earth Sciences Date Project Name Project No. Report No. 12/27/2022 Stark Residence Foundation Repairs 20210191EO02 017 Table 2: Sheet S2.1 PILE & ANCHOR SCHEDULE PILE TYPE DESIGN LOAD PILE SHAFT HELIX CONFIGURATION MIN INSTALL TORQUE MAX INSTALL TORQUE KT NOTES Pl-P24 2"0 PIN PILE 6.OK 2" STD PIPE - - - H1-H11 PIPE HELICAL PILE 14.OK 2 7/8" x 0.203" PIPE HELIX DOUBLE HELIX (8",10") 3,100 FT# 5,500 FT# 9 LOCK OFF SNUG TIGHT ONLY H12-HIS PIPE HELICAL PILE 13.OK 2 7/8" x 0.203" PIPE HELIX DOUBLE HELIX (8",10") 2,800 FT# 5,500 FT# 9 LOCK OFF SNUG TIGHT ONLY H16-H2O PIPE HELICAL PILE I 14.0K 2 7/8" x 0.203" PIPE HELIX DOUBLE HEUX (8", loll) 3,100 FT# 5,500 FT# 9 1 LOCK OFF SNUG TIGHT ONLY NOTES: 1. CONTRACTOR SHALL VERIFY HELIX CONFIGURATION CAPABLE OF DEVELOPING THE DESIGN LOADS. 2. MIN INSTALL TORQUE ASSUMES Kt= 9.0IF A PILE WITH A DIFFERENT Kt VALUE IS USED MIN INSTALL TORQUE SHALL BE ADJUSTED. 3. MIN INSTALL TORQUE INCLUDES A FACTOR OF SAFETY OF 2.0. 4. ALL PILES SHALL INSTALLED TO TWICE THE DESIGN LOAD. Figure 1: Pipe Pile and Helical Pile Plan. Helical anchors installed today shown in purple shade, previously installed shown as purple circles. 11 LOWER LEVEL PLAN Page 2 of 3 FIELD REPORT 8A S1 Associated Earth Sciences Date Project Name Project No. Report No. 12/27/2022 Stark Residence Foundation Repairs 20210191EO02 017 Figure 2: Revised Pipe Pile and Helical Pile Plan OUTPUT SPEED & TORQUE HH-6K SPECIFICATIONS 91 Digga HH-6K Screw Anchor Drive HH-6K MM-10K OUTPUT SPEED OUTPUT Theoretical Torque (ft-Ibs) 6,528 @ 2,100psi 10,478 @ 3,000psi GPM RPM PSI FT-LBS Expected Torque (ft-Ibs) 4,765 @ 2,100psi 8,040 @ 3,000psi 7 7 500 1,554 c"YJ(77%efficiency) 8 8 750 2,331 Max Pressure 2,100psi @ 11gpm 3,000psi @ 18.5gpm 9 9 1,000 3,108 Max Flow 15gpm @ 2300psi 18.5gpm @ 3000psi Max Horse Power 20 33 10 10 1,250 3,886 Pressure Relief Valve Included NA 11 11 1,500 4,663 Standard Output Shaft 2'Hex 2.5'Hex-Short 12 12 1,750 5,440 13 13 2,000 6,217 Weight (Ibs) 90 138 14 14 2,100 6,528 Overall Length (in) 20" 24.1' 15 is Diameter (in) 9.5" 11.4' HH-61K Hand-held unit is not suitable for machine mounting. Warranty void if used on machines. Page 3 of 3