Building Permit_1Type: COMMERCIAL BLDG Subtype: TOWNHOMES 3 OR MORE I Status: ISSUED
Parcel No: 00451900102000 Site Address: 8029 238TH ST SW EDMONDS,WA 98026-9265
Subdivision: 010230, 004519, SP S-2-86, SP S-15-87 Lot: 0
Fire Sprinklers: Yes Lot Area: Zoning:
Valuation: $951,231.06 Occupancy Type: R-3 Construction Type: VB
Code Edition: 2018 No. Stories: 2 # of Dwelling Units: 4
Scope of Work: EDMONDS TOWNHOMES-NEW 4 UNIT TOWNHOMES, P&M INCLUDED
Applied: 1/25/2021
Issued:10/6/2022
Final:
Expiration Date: 10/6/2024
Issued by: BAC
I WA State Contractor L & I #: LRBUIRB837B6 I
11
•
NAME TYPE
NAME
ADDRESS
PHONE
EMAIL
APPLICANT
JESSE MAYOR -GOOD NAME
(206)387-8008
JMAYOR88@GMAIL.COM
PROPERTIES LLC
CONTACT
ATLAS ARCHITECTS
5280 HIGHAND
DR., BELLEVUE
(206)488-3688
gengtan@gmail.com
WA 98006
6619 132and Ave NE PMB 127,
CONTRACTOR
L & R BUILDERS LLC
cj@bellproperties.net
KIRKLAND WA
98033
EDMONDS TOWNHOMES-
8029 238TH ST SW, EDMONDS
OWNER
BETTER BELLEVUE INC
WA 98026-9265
PRIMARY
SERGEY ANTOYNUK
CJ@BELLPROPERTIES.NET
CONTACT
PRIOR
PACIFIC RED DOOR
2415 130TH AVE NE, BELLEVUE
CONTRACTOR
DEVELOPMENT INC
WA 98005
FEE
INFORMATION
DESCRIPTION
ACCOUNT
AMOUNT
PAID
PAID DATE RECEIPT#
1 - BASE FEE FOR MECHANICAL
001.000.322.10.000.00
$50.00
$50.00
10/5/22
R23522
PERMITS
1 - BASE FEE FOR PLUMBING
001.000.322.10.000.00
$50.00
$50.00
10/5/22
R23522
PERMITS
2020 TRANSPORTATION IMPACT
112.502.345.86.000.00
$12,431.80
$12,431.80
10/5/22
R23522
FEE
APPLIANCE VENTS
001.000.322.10.000.00
$120.00
$120.00
10/5/22
R23522
BLD - PERMIT RENEWAL
001.000.345.83.000.00
$1,723.00
$1,723.00
10/3/23
R31692
CITY TECHNOLOGY FEE CHARGED
001.000.321.99.100.00
$40.00
$40.00
10/5/22
R23522
PER PERMIT
COMMERCIAL STATE SURCHARGE
001.000.237.150
$25.00
$25.00
10/5/22
R23522
EACH PLUMBING FIXTURE ON ONE
001.000.322.10.000.00
$840.00
$840.00
10/5/22
R23522
TRAP
FAN CONNECTED TO SINGLE DUCT
001.000.322.10.000.00
$300.00
$300.00
10/5/22
R23522
FURNACE OR FIREPLACE
001.000.322.10.000.00
$120.00
$120.00
10/5/22
R23522
GAS PIPING - NEW OR LOCATED
001.000.322.10.000.00
$45.00
$45.00
10/5/22
R23522
PARK IMPACT FEE - COM ADMIN
001.000.322.10.000.00
$100.00
$100.00
10/5/22
R23522
Printed: Thursday, January 11, 2024 11:15:40 AM 1 of 4
DESCRIPTION
ACCOUNT AMOUNT
PAID PAID DATE
RECEIPT #
PARK IMPACT FEE - MULTI FAMILY
332.100.345.85.000.00
$6,626.59
$6,626.59
10/5/22
R23522
PERMIT FEE - COMMERCIAL
001.000.322.10.000.00
$6,892.00
$6,892.00
10/5/22
R23522
PLAN REVIEW FEE - COMMERCIAL
001.000.345.83.000.00
$5,858.20
$5,858.20
2/12/21
R10535
STATE BUILDING CODE SURCHARGE
001.000.237.150
$6.00
$6.00
10/5/22
R23522
EACH ADDL DWELLING UNITS
STORMWATER GENERAL FACILITY
422.000.379.00.000.00
$1,010.20
$1,010.20
10/5/22
R23522
CHARGE MF COMM
TRANSPORTATION IMPACT ADMIN
001.000.341.82.000.00
$100.00
$100.00
10/5/22
R23522
FEE - MF COMM
WATER HEATER - TANKLESS
001.000.322.10.000.00
j $60.00
j $60.00
j 10/5/22
j R23522
TOTALS: $36,397.79 $36,397.79
CONDITIONS
CONDITION TYPE
STATUS
NOTES
1- HOLD HARMLESS - Applicant on behalf of his or her spouse heirs assigns and successors
in interests, agrees to indemnify defend and hold harmless the City of Edmonds,
Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly from the issuance of this permit. Issuance
of this permit shall not be deemed to modify, waive or reduce any requirements of any
City ordinance nor limit in any way the City's ability to enforce any ordinance provision.
\r\n2 - PERMIT DISCLOSURE - Any request for alternate design, modification, variance or
other administrative deviation from adopted codes ordinances or policies must be
specifically requested in writing and be called out and identified. Processing fees for such
requests shall be established by Council and shall be paid upon submittal and are
nonrefundable.\r\n3- SOUND OR NOISE - Sound/Noise originating from temporary
FOR
construction sites as a result of construction activity are exempt from the noise limits of
ALL BUILDING PERMITS
INFORMATION
ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am
to 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the
noise originating from construction sites/activities must comply with the noise limits of
Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.\r\n4 -
OCCUPANCY - Final approval on a project or final occupancy approval must be granted by
the Building Official prior to use or occupancy of the building or structure. Check the job
card for all required City inspections including final project approval and final occupancy
inspections. \r\n5 - PLUMBING - Plumbing contractor license laws are regulated by
Chapter 18.106 RCW. Property owners who hire an unlicensed plumber may assume the
risks and potential monetary liability for work performed by unlicensed plumbing
contractors. For more information contact L&I Department of Licensing at 1-800-647-
0982.
Pre -inspection required. Street to be cleaned of debris. Side sewer must be capped at
DEMOLITION REQUIREMENTS
FOR
property line. Water Service must be disconnected from Water Meter and or hose bib
INFORMATION
with AVB installed. Dump at approved dump site only.
ELECTRICAL PERMIT
FOR
Obtain Electrical Permit from State Department of Labor and Industries 425-290-1309.
NFORMATION
FOR
In addition to the required pressure relief valve an approved listed expansion tank shall
EXPANSION TANK
INFORMATION
be installed on all hot water tanks per UPC 608.
FIRE FINAL INSPECTION
FOR
Request final Fire Department Inspection 425-775-7720.
NFORMATION
Approval of this foundation design is conditional subject to inspection of existing site soil
FOR
conditions. Retaining walls must be designed and constructed to resist the lateral
FOUNDATION BEARING
INFORMATION
pressure of the retained material. Provisions must be made for the control and drainage
of surface water around buildings.
Printed: Thursday, January 11, 2024 11:15:40 AM 2 of 4
rMERCIAL BLDG Permit
PERMIT NUM
City of Edmonds
2-00941
ww.edmondswa.gov
GAS PIPE TEST
FOR
Gas pipe test must be observed by City Building Inspector, affidavits shall not be accepted
NFORMATION
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests,
agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its
FOR
officials, employees, and agents from any and all claims for damages of whatever nature,
HOLD HARMLESS
INFORMATION
arising directly or indirectly from the issuance for this permit. Issuance of this permit shall
not be deemed to modify, waive or reduce any requirements of any City ordinance nor
limit in any way the City's ability to enforce any ordinance provision.
Installation, use and maintenance of equipment and components shall be per
MANUFACTURER SPECS
FOR
manufacturers specifications, installation instructions, and applicable state codes.
INFORMATION
Provide manufactures installation instructions on site for Building Inspector.
Maximum Height 25 feet. The agent or contractor shall set up the equipment; establish
the datum point and the point of average grade. Call for inspections to verify. These
MAXIMUM HEIGHT
FOR
items must be consistent with the approved plan. If the proposed height of a building is
INFORMATION
within 12 inches of the maximum height permitted for the zone an elevation survey is
required.
New and existing buildings shall have approved address numbers, building numbers or
approved building identification placed in a position that is plainly visible from the street
POST ADDRESS
FOR
or road fronting the property. Address numbers shall be Arabic numerals or alphabet
INFORMATION
letters Numbers shall be legible from the public way, at least 6 inches high with a .75inch
min stroke width on a contrasting background.
The building enclosure must be inspected by a qualified inspector in accordance with
RCW 64.55.030, 64.55.040, and 64.55.050. A building enclosure certification letter from
the inspector must be submitted to the Building Division prior to final inspection by the
RCW 64.55 BUILDING
FOR
City Building Inspector in accordance with RCW 64.55.060. Where phasing of construction
ENCLOSURE
INFORMATION
occurs, coordinate inspection with the City Building Inspector to ensure that all required
inspections are performed. Inspection by the building enclosure inspector to meet RCW
64.55 does not substitute for required City building inspections which must be performed
by the City Building Inspector.
FOR
Heat pumps, AC units and similar equipment greater than 36 inches in height are not
SIDE YARD EQUIPMENT
INFORMATION
allowed within required building setbacks.
Installer shall provide the manufacturer installation, operating instructions, and a whole
WHOLE HOUSE FAN
FOR
house ventilation system operation description. A label shall be affixed to the whole
INFORMATION
house timer control that reads "Whole house ventilation, see operating instructions".
wr
INSPECTIONTYPE INSPECTOR
COMPLETED
RESULT
NOTES
A-1 BUILDING PRECON
B-2 SLAB INSULATION
B-3 EXT WALL SHEATHING
B-3 GAS PIPING TEST
B-3 MECH ROUGH IN
B-3 PLUMB ROUGH IN
B-3 ROOF SHEATHING
B-3 UNDERFLR FRAMING
B-4 DRYWALL FASTENING
B-4 FRAMING
B-4 INTERIOR SHEAR
Printed: Thursday, January 11, 2024 11:15:40 AM 3 of 4
JWMMT
Permit
W_
121 5th Ave N, Edmonds WA 98020 BLD2021-030914
. •.
B-4 SHOWER PAN
B-5 BUILDING ENCLOSURE
B-5 INSULATION ENERGY
B-7 BUILDING OTHER INSP
X-3 BUILDING FINAL"
A-1 TESC AND MOBILIZE
E-4 WATER SERVICE LINE
X-2 ENGINEERING FINAL
A-1 ENGINEERING PRECON
9/28/2023
CORRECTION
If possible, call me and let me know when the
12:00:00 AM
REQUIRED
inspector will be there. CJ 425-985-9325
A-1 ENGINEERING PRECON
9/28/2023
CORRECTION
Contractor did not have the approved civil plans. Only
12:00:00 AM
REQUIRED
discussed demo requirements and inspections.
Another pre -con shall be required prior to starting
construction.
A-1 ENGINEERING PRECON
B-2 FOOTINGS
11/2/2023
APPROVED
Approved
12:00:00 AM
B-1 SETBACKS
11/2/2023
CORRECTION
if possible a call from inspector what time can he
12:00:00 AM
REQUIRED
make it.
B-1 SETBACKS
11/2/2023
CORRECTION
Measure setbacks at foundation wall.
12:00:00 AM
REQUIRED
B-1 SETBACKS
12/11/2023
APPROVED
If I can get a call for the rough time, that would be
12:00:00 AM
great
B-1 SETBACKS
12/11/2023
APPROVED
Approved per footing surveyed pins.
12:00:00 AM
B-2 FOUNDATION WALL
12/11/2023
PARTIAL
Foundation walls approved excluding SW corner.
12:00:00 AM
APPROVAL
Catch basin to be moved soon.
B-2 FOUNDATION WALL
E-3 STRM FOOTING DRAIN
E-3 STRM FOOTING DRAIN
12/20/2023
PARTIAL
4" perf pipe installed around the north, west and
12:00:00 AM
APPROVAL
south sides of the foundation with washed rock and
Pieter fabric. Still need to see the footing drains in the
SW corner of the foundation and connection to
outlet.
E-3 STRM TIGHTLINE
E-3 STRM TIGHTLINE
12/20/2023
PARTIAL
4" PVC installed along the west side of the foundation
12:00:00 AM
APPROVAL
sloping towards the south.
Printed: Thursday, January 11, 2024 11:15:40 AM 4 of 4