Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2024-0071_Site_Plan_1.17.2024_7.31.10_AM_4003263
Air Conditioning & Heating Standard Features • High -efficiency scroll compressor • Factory -installed filter drier • Fully charged for 15' of tubing length • Copper tube/enhanced aluminum fin coil-5mm diameter on 1.5-3.OT • Service valves with sweat connections and easy -to -access gauge ports • Contactor with lug connection • Ground lug connection • AHRI Certified • ETL Listed GSXH.5 HIGH -EFFICIENCY SPLIT SYSTEM AIR CONDITIONER UP To 17 SEER2 1'z TO 5 ToNs Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Expanded Cooling Data ......................... 4 Performance Data ............................... 18 Dimensions..........................................19 Wiring Diagrams ................................. 20 Accessories .......................................... 22 Cabinet Features • Removable grille -style top design compliant with UL 60335-2-40 • Venturi for increased velocity of airflow • Heavy -gauge galvanized -steel cabinet • Attractive Architectural Gray powder -paint finish with 500-hour salt -spray approval • Steel louver coil guard • Rust -resistant coated screws • Single -panel access to controls with space provided for field -installed accessories • When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane -type winds (Anchor bracket kits available.) Proper sizing and installation of equipment is p gc PARTS (/DTI, COMPANY WIT. COMPANY WITH 1 U LIMITED c \II us GTIFIEDVAL BY DNV ECRONIED BY SYSTEM CERTIFIED BY DNV GL CERTIFIED BV DNV GL critical to achieving optimal performance. Split YEAR WARRANTY'=1509001= =ISO 14 1= system air conditioners and heat pumps must BIBIi� be matched with appropriate coil components to * Complete warranty details available from your local dealer or at www.goodmanmfg.com. meet ENERGY STAR® criteria. Ask your contractor To receive the 10-Year Parts Limited Warranty, online registration must be completed within for details or visit www.energystar.gov. 60 days of installation. Online registration is not required in California or Quebec. The duration of warranty coverages in Texas differs in some cases. SS-GSXHS www.goodmanmfg.com 06/23 Supersedes 11/22 NOMENCLATURE G S X H 5 0 36 1 0 ** 4 5 6 1 2 3 7,8 9 10 11,12 BRAND ENGINEERING G- Goodman® Brand Major/Minor Revisions A - Initial Release B - 1st Revision PRODUCT CATEGORY VARIATION S Split System R-410A UNIT TYPE ELECTRICAL X Condenser 1 208/230 V, 1 Phase, 60 Hz Z Heat Pump FEATURE NOMINAL CAPACITY N Value H Enhanced 18- 1.5 Ton 42- 3.5 Tons B Classic C Premium M Multi -Family V Ultimate 24-2.OTons 48-4.OTons 30- 2.5 Tons 60- 5.0 Tons 36- 3.0 Tons SEER2 SALES REGION 13.4- 13.7 = 3 16.6- 17.5 = 7 N North 13.8- 14.5 = 4 17.6- 18.5 = 8 S Southeast & North 14.6- 15.5 = 5 18.6- 19.5 = 9 0 All Regions 15.6- 16.5 = 6 19.6 + = 0 2 www.goodmanmfg.com SS-GSXHS PRODUCT SPECIFICATIONS I 0.0I CAPACITIES Nominal Cooling (BTU/h) 18,000 24,000 30,000 36,000 42,000 48,000 60,000 SEER2 15.2 15.2 15.2 15.2 15.2 15.2 15.2 Decibels (dBA) 72 73 72 75 72 73 76 COMPRESSOR RLA 9.0 11.5 12.8 14.1 177 19.9 23.7 LRA 42.6 59.5 65 87.4 110.2 110 151 Stage Single Single Single Single Single Single Two Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll CONDENSER FAN MOTOR Motor Type PSC PSC PSC PSC PSC PSC ECM Horsepower 1/8 1/6 1/6 1/6 1/4 1/4 1/3 FLA 0.70 0.95 0.95 0.95 1.30 1.30 2.80 REFRIGERATION SYSTEM Refrigerant Line Size I Liquid Line Size ("O.D.) /a" W. 3%11 %8' 3/8' 3/s' W, Suction Line Size ("O.D.) /" %" %" %V 1%" 1%" Refrigerant Connection Size Liquid Valve Size ("O.D.) 3%11 3%11 '/s' '/8' %" W, %" Suction Valve Size ("O.D.) 23 %" %" %" Y" Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Refrigerant Charge 4 64 72 101 102 177 180 209 ELECTRICAL DATA Voltage-Phase(60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 Minimum Circuit Ampacity 1 11.9 15.3 17.0 18.6 23.4 26.2 32.4 Max. Overcurrent Protection e 20 25 25 30 40 45 50 Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size %:" or %" W. or %" W. or W W. or W '/:" or %" %" or %" %" or W EQUIPMENT WEIGHT (LBS) 126 151 202 202 260 260 283 SHIP WEIGHT (LBS) 144 169 224 224 282 282 305 ENERGY STAR® CERTIFIED Line sizes denoted for 25' line sets, tested and rated in accordance with ARI Standard 210/240. For other line set lengths or sizes, refer to the Installation Instructions and/or the Long Line Set Applications guide. 2 Installer will need to supply %" to %" adapters for suction line connections. 3 Installer will need to supply %" to 1%" adapters for suction line connections. 4 Unit is factory charged with refrigerant for 15' of %" liquid line. System charge must be adjusted per the Final Charge Adjustment procedure found in the Installation Instructions. 5 Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes 6 Must use time -delay fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. ENERGY STAR NOTES • Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. • Ask your contractor for details or visit www.energystar.gov. The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements. SS-GSXH5 www.goodmanmfg.com 0 0 0 0- 3 a 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 6591F 752F 852E I 959E 1052F 1152E ENTERING INDOOR WET BULB TEMPERATURE D: MBh 17.8 18.0 18.6 - 17.6 17.9 18.4 - 17.2 17.4 18.0 - 16.4 16.6 17.2 - 15.4 15.7 16.2 - 14.5 14.8 15.3 - S/T 0.60 0.53 0.40 0.61 0.54 0.41 0.63 0.56 0.43 0.65 0.58 0.45 1.00 0.60 0.47 1.00 0.65 0.52 AT 21 19 15 21 19 15 21 19 15 21 19 15 20 18 15 22 20 16 510 kW 1.07 1.07 1.07 1.19 1.19 1.18 1.31 1.31 1.31 1.45 1.45 1.45 1.60 1.60 1.60 1.78 1.78 1.78 Amps 3.8 3.8 3.8 4.3 4.3 4.3 4.9 4.9 4.9 5.5 5.5 5.5 6.2 6.2 6.2 7.0 7.0 7.0 Hi PR 239 240 242 277 278 280 317 318 319 359 360 362 405 406 408 454 455 456 Lo PR 1 123 125 128 130 132 135 137 139 142 143 144 147 148 149 153 155 156 159 MBh 18.1 18.4 18.9 18.0 18.2 18.8 17.5 17.8 18.3 16.7 17.0 17.5 15.7 16.0 16.5 14.9 15.1 15.6 S/T 0.66 0.58 0.46 0.66 0.59 0.46 0.69 0.61 0.49 1.00 0.63 0.50 1.00 0.65 0.53 1.00 0.70 0.57 AT 19 17 14 19 17 14 20 18 14 19 17 14 19 17 13 20 18 15 70 600 kW 1.08 1.08 1.08 1.19 1.19 1.19 1.32 1.32 1.32 1.46 1.46 1.45 1.61 1.61 1.61 1.79 1.79 1.79 Amps 3.8 3.8 3.8 4.4 4.3 4.3 4.9 4.9 4.9 5.6 5.6 5.5 6.3 6.3 6.2 7.1 7.1 7.1 HiPR 242 243 245 280 281 282 319 320 322 362 363 364 407 408 410 456 457 459 Lo PR 126 127 130 133 134 138 139 141 144 145 146 150 150 152 155 157 159 162 MBh 18.6 18.8 19.3 18.4 18.7 19.2 17.9 18.2 18.7 17.1 17.4 17.9 16.2 16.4 17.0 15.3 15.5 16.1 S/T 0.67 0.60 0.47 0.68 0.61 0.48 0.70 0.63 0.50 1.00 0.65 0.52 1.00 0.67 0.54 1.00 0.72 0.59 AT 18 16 13 18 16 12 18 16 13 18 16 12 18 16 12 19 17 13 690 kW 1.09 1.09 1.08 1.20 1.20 1.20 1.33 1.32 1.32 1.46 1.46 1.46 1.62 1.61 1.61 1.79 1.79 1.79 Amps 3.9 3.9 3.8 4.4 4.4 4.4 5.0 5.0 4.9 5.6 5.6 5.6 6.3 6.3 6.3 7.1 7.1 7.1 HiPR 245 246 247 282 283 285 322 323 324 364 365 367 410 411 413 459 460 462 Lo PR 128 130 133 136 137 141 142 144 147 148 149 153 153 155 158 160 162 165 MBh 17.8 18.1 18.6 19.4 17.6 17.9 18.4 19.2 17.2 17.4 18.0 18.8 16.4 16.6 17.2 18.0 15.4 15.7 16.2 17.0 14.5 14.8 15.3 16.1 S/T 0.72 0.65 0.52 0.4 0.73 0.66 0.53 0.4 1.00 0.68 0.55 0.4 1.00 0.70 0.57 0.4 1.00 0.72 0.59 0.5 1.00 1.00 0.64 0.5 AT 25 23 19 16 25 23 19 16 25 23 20 16 25 23 19 16 25 23 19 15 26 24 20 16 510 kW 1.07 1.07 1.07 1.1 1.19 1.19 1.18 1.2 1.31 1.31 1.31 1.3 1.45 1.45 1.45 1.5 1.60 1.60 1.60 1.6 1.78 1.78 1.78 1.8 Amps 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.9 4.9 4.9 4.9 5.5 5.5 5.5 5.5 6.2 6.2 6.2 6.2 7.0 7.0 7.0 7.1 Hi PR 240 241 242 246.5 277 278 280 284.2 317 318 319 323.6 359 360 362 366.1 405 406 408 411.9 454 455 457 460.8 Lo PR 123 125 128 132.9 131 132 135 140.3 137 139 142 146.9 143 144 147 152.4 148 149 153 157.8 155 156 159 164.5 MBh 18.1 18.4 18.9 19.7 18.0 18.2 18.8 19.6 17.5 17.8 18.3 19.1 16.7 17.0 17.5 18.3 15.8 16.0 16.5 17.3 14.9 15.1 15.6 16.5 S/T 0.78 0.71 0.58 0.4 0.79 0.71 0.58 0.4 1.00 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 0.78 0.65 0.5 1.00 1.00 0.70 0.6 AT 24 22 18 14 24 22 18 14 24 22 18 14 24 22 18 14 23 21 18 14 25 23 19 15 75 600 kW 1.08 1.08 1.08 1.09 1.19 1.19 1.19 1.20 1.32 1.32 1.32 1.33 1.46 1.46 1.45 1.46 1.61 1.61 1.61 1.61 1.79 1.79 1.78 1.79 Amps 3.8 3.8 3.8 3.9 4.3 4.3 4.3 4.4 4.9 4.9 4.9 5.0 5.6 5.5 5.5 5.6 6.3 6.2 6.2 6.3 7.1 7.1 7.1 7.1 Hi PR 242 243 245 249.1 280 281 283 286.8 319 320 322 326.2 362 363 365 368.7 408 409 410 414.5 456 458 459 463.4 Lo PR 126 127 130 135.4 133 135 138 142.8 140 141 144 149.3 145 147 150 154.9 150 152 155 160.3 157 159 162 167.0 MBh 18.6 18.8 19.4 20.2 18.4 18.7 19.2 20.0 18.0 18.2 18.7 19.5 17.2 17.4 17.9 18.7 16.2 16.4 17.0 17.8 15.3 15.5 16.1 16.9 S/T 0.80 0.72 0.60 0.5 1.00 0.73 0.60 0.5 1.00 0.75 0.63 0.5 1.00 0.77 0.64 0.5 1.00 1.00 0.67 0.5 1.00 1.00 0.71 0.6 AT 22 20 17 13 22 20 17 13 23 21 17 13 22 20 17 13 22 20 16 13 23 21 18 14 690 kW 1.09 1.08 1.08 1.1 1.20 1.20 1.20 1.2 1.33 1.32 1.32 1.3 1.46 1.46 1.46 1.5 1.61 1.61 1.61 1.6 1.79 1.79 1.79 1.8 Amps 3.9 3.9 3.8 3.9 4.4 4.4 4.4 4.4 5.0 4.9 4.9 5.0 5.6 5.6 5.6 5.6 6.3 6.3 6.3 6.3 7.1 7.1 7.1 7.1 Hi PR 245 246 248 251.8 283 284 285 289.4 322 323 325 328.9 364 365 367 371.3 410 411 413 417.1 459 460 462 466.0 Lo PR 128 130 133 138.3 136 137 141 145.7 142 144 147 152.3 148 149 153 157.8 153 155 158 163.2 160 162 165 170.0 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW =Total system power k n 0 0 0 sZ v 3 dip 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 17.9 18.1 18.7 19.5 17.7 18.0 18.5 19.3 17.3 17.5 18.1 18.9 16.5 16.7 17.3 18.1 15.5 15.8 16.3 17.1 14.6 14.9 15.4 16.2 S/T 1.00 0.77 0.64 0.5 1.00 0.78 0.65 0.5 1.00 0.80 0.67 0.5 1.00 0.82 0.69 0.6 1.00 1.00 0.71 0.6 1.00 1.00 0.76 0.6 AT 29 27 24 20 29 27 24 20 30 28 24 20 29 27 24 20 29 27 23 20 30 28 25 21 510 kW 1.07 1.07 1.07 1.1 1.19 1.19 1.18 1.2 1.31 1.31 1.31 1.3 1.45 1.45 1.45 1.5 1.60 1.60 1.60 1.6 1.78 1.78 1.78 1.8 Amps 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.9 4.9 4.9 4.9 5.5 5.5 5.5 5.6 6.2 6.2 6.2 6.2 7.0 7.0 7.0 7.1 HIM 240 241 243 247.0 278 279 280 284.6 317 318 320 324.1 360 361 362 366.5 405 407 408 412.3 454 455 457 461.2 Lo PR 124 125 128 133.4 131 133 136 140.9 138 139 142 147.4 143 145 148 152.9 148 150 153 158.3 155 157 160 165.1 MBh 18.2 18.5 19.0 19.8 18.1 18.3 18.9 19.7 17.6 17.9 18.4 19.2 16.8 17.1 17.6 18.4 15.8 16.1 16.6 17.4 15.0 15.2 15.7 16.5 S/T 1.00 0.83 0.70 0.6 1.00 0.83 0.70 0.6 1.00 0.86 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.82 0.7 AT 28 26 22 19 28 26 22 18 28 26 23 19 28 26 22 18 28 26 22 18 29 27 23 19 80 600 kW 1.08 1.08 1.08 1.09 1.19 1.19 1.19 1.20 1.32 1.32 1.32 1.33 1.46 1.46 1.45 1.46 1.61 1.61 1.61 1.61 1.79 1.79 1.79 1.79 Amps 3.8 3.8 3.8 3.9 4.4 4.3 4.3 4.4 4.9 4.9 4.9 5.0 5.6 5.6 5.5 5.6 6.3 6.2 6.2 6.3 7.1 7.1 7.1 7.1 Hi PR 243 244 245 249.6 280 281 283 287.2 320 321 323 326.7 362 363 365 369.1 408 409 411 414.9 457 458 460 463.8 Lo PR 126 128 131 135.9 134 135 138 143.4 140 142 145 149.9 146 147 150 155.4 151 152 156 160.8 158 159 162 167.6 MBh 18.7 18.9 19.4 20.3 18.5 18.8 19.3 20.1 18.0 18.3 18.8 19.6 17.2 17.5 18.0 18.8 16.3 16.5 17.1 17.9 15.4 15.6 16.2 17.0 S/T 1.00 0.84 0.71 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.83 0.7 AT 27 25 21 17 27 25 21 17 27 25 21 18 27 25 21 17 26 25 21 17 28 26 22 18 690 kW 1.09 1.09 1.08 1.1 1.20 1.20 1.20 1.2 1.33 1.32 1.32 1.3 1.46 1.46 1.46 1.5 1.61 1.61 1.61 1.6 1.79 1.79 1.79 1.8 Amps 3.9 3.9 3.8 3.9 4.4 4.4 4.4 4.4 5.0 5.0 4.9 5.0 5.6 5.6 5.6 5.6 6.3 6.3 6.3 6.3 7.1 7.1 7.1 7.1 Hi PR 245 246 248 252.2 283 284 286 289.9 322 323 325 329.3 365 366 368 371.8 411 412 413 417.6 460 461 462 466.4 Lo PR 1 129 131 134 138.8 136 138 141 146.3 143 144 148 152.8 148 150 153 158.3 154 155 159 163.7 161 162 165 170.5 MBh 18.2 18.4 19.0 19.8 18.0 18.3 18.8 19.6 17.6 17.8 18.4 19.2 16.8 17.0 17.6 18.4 15.8 16.1 16.6 17.4 14.9 15.2 15.7 16.5 S/T 1.00 0.87 0.74 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 0.81 0.7 1.00 1.00 1.00 0.7 AT 33 31 28 24 33 31 28 24 33 32 28 24 33 31 28 24 33 31 27 23 34 32 29 25 510 kW 1.08 1.07 1.07 1.1 1.19 1.19 1.19 1.2 1.32 1.31 1.31 1.3 1.45 1.45 1.45 1.5 1.60 1.60 1.60 1.6 1.78 1.78 1.78 1.8 Amps 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.4 4.9 4.9 4.9 4.9 5.5 5.5 5.5 5.6 6.2 6.2 6.2 6.3 7.1 7.0 7.0 7.1 Hi PR 241 242 244 248.1 279 280 282 285.8 318 319 321 325.2 361 362 364 367.7 407 408 409 413.5 455 456 458 462.3 Lo PR 125 127 130 135.3 133 134 138 142.7 139 141 144 149.2 145 146 150 154.7 150 152 155 160.1 157 159 162 166.9 MBh 18.5 18.8 19.3 20.1 18.4 18.6 19.2 20.0 17.9 18.2 18.7 19.5 17.1 17.4 17.9 18.7 16.1 16.4 16.9 17.7 15.3 15.5 16.0 16.8 S/T 1.00 0.92 0.79 0.7 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 1.00 0.8 AT 32 30 26 22 32 30 26 22 32 30 26 23 32 30 26 22 32 30 26 22 33 31 27 23 85 600 kW 1.08 1.08 1.08 1.09 1.20 1.19 1.19 1.20 1.32 1.32 1.32 1.33 1.46 1.46 1.46 1.46 1.61 1.61 1.61 1.62 1.79 1.79 1.79 1.80 Amps 3.8 3.8 3.8 3.9 4.4 4.4 4.3 4.4 4.9 4.9 4.9 5.0 5.6 5.6 5.6 5.6 6.3 6.3 6.3 6.3 7.1 7.1 7.1 7.1 Hi PR 244 245 247 250.7 281 283 284 288.3 321 322 324 327.8 363 364 366 370.3 409 410 412 416.1 458 459 461 464.9 Lo PR 128 129 133 137.8 135 137 140 145.2 142 143 147 151.7 147 149 152 157.2 153 154 157 162.6 160 161 164 169.4 MBh 19.0 19.2 19.7 20.6 18.8 19.1 19.6 20.4 18.3 18.6 19.1 19.9 17.5 17.8 18.3 19.1 16.6 16.8 17.4 18.2 15.7 15.9 16.5 17.3 S/T 1.00 0.94 0.81 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.8 AT 31 29 25 21 31 29 25 21 31 29 25 21 31 29 25 21 30 28 25 21 32 30 26 22 690 kW 1.09 1.09 1.09 1.1 1.20 1.20 1.20 1.2 1.33 1.33 1.32 1.3 1.46 1.46 1.46 1.5 1.62 1.62 1.61 1.6 1.80 1.80 1.79 1.8 Amps 3.9 3.9 3.9 3.9 4.4 4.4 4.4 4.4 5.0 5.0 5.0 5.0 5.6 5.6 5.6 5.6 6.3 6.3 6.3 6.3 7.1 7.1 7.1 7.1 Hi PR 246 247 249 253.3 284 285 287 291.0 324 325 326 330.4 366 367 369 372.9 412 413 415 418.7 461 462 463 467.6 Lo PR 131 132 135 140.7 138 140 143 148.1 145 146 149 154.6 150 152 155 160.1 156 157 160 165.6 162 164 167 172.3 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k 0 n 0 0 0 sZ 3 a 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652E F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 24.0 24.4 25.1 - 23.8 24.1 24.9 - 23.2 23.5 24.2 - 22.1 22.4 23.2 - 20.8 21.1 21.8 - 19.6 19.9 20.6 - S/T 0.58 0.51 0.38 0.58 0.51 0.38 0.61 0.54 0.41 0.63 0.55 0.43 1.00 0.57 0.45 1.00 0.62 0.49 AT 20 18 15 20 18 15 20 18 15 20 18 15 20 18 14 21 19 15 700 kW 1.43 1.43 1.42 1.58 1.58 1.57 1.74 1.74 1.74 1.92 1.92 1.92 2.13 2.12 2.12 2.36 2.36 2.36 Amps 4.9 4.9 4.9 5.6 5.6 5.6 6.4 6.4 6.3 7.2 7.2 7.2 8.1 8.1 8.1 9.2 9.2 9.2 HiPR 239 240 241 276 277 279 316 317 318 358 359 361 404 405 406 453 454 455 Lo PR 122 124 127 129 131 134 136 137 141 141 143 146 147 148 151 154 155 158 MBh 24.3 24.7 25.4 24.1 24.4 25.2 23.5 23.8 24.5 22.4 22.7 23.5 21.1 21.4 22.1 19.9 20.2 20.9 S/T 0.63 0.56 0.43 0.64 0.57 0.44 0.66 0.59 0.46 1.00 0.61 0.48 1.00 0.63 0.50 1.00 0.68 0.55 AT 19 17 14 19 17 13 19 17 14 19 17 13 19 17 13 20 18 14 70 795 kW 1.44 1.43 1.43 1.58 1.58 1.58 1.75 1.75 1.75 1.93 1.93 1.93 2.13 2.13 2.13 2.37 2.37 2.37 Amps 5.0 4.9 4.9 5.6 5.6 5.6 6.4 6.4 6.4 7.2 7.2 7.2 8.1 8.1 8.1 9.2 9.2 9.2 HiPR 240 241 243 278 279 281 317 319 320 360 361 363 406 407 408 455 456 457 Lo PR 124 125 128 131 133 136 138 139 142 143 145 148 149 150 153 155 157 160 MBh 24.8 25.1 25.8 24.6 24.9 25.6 24.0 24.3 25.0 22.9 23.2 23.9 21.6 21.9 22.6 20.3 20.7 21.4 S/T 0.67 0.60 0.47 0.67 0.60 0.47 0.70 0.63 0.50 1.00 0.64 0.51 1.00 0.66 0.54 1.00 0.71 0.58 AT 18 16 12 18 16 12 18 16 13 18 16 12 17 16 12 19 17 13 915 kW 1.44 1.44 1.44 1.59 1.59 1.59 1.76 1.76 1.76 1.94 1.94 1.94 2.14 2.14 2.14 2.38 2.38 2.37 Amps 5.0 5.0 5.0 5.7 5.7 5.7 6.4 6.4 6.4 7.3 7.3 7.2 8.2 8.2 8.2 9.3 9.3 9.2 HiPR 243 244 246 280 281 283 320 321 323 362 363 365 408 409 411 457 458 460 Lo PR 126 128 131 134 135 138 140 142 145 146 147 150 151 152 156 158 159 162 MBh 24.0 24.4 25.1 26.2 23.8 24.2 24.9 26.0 23.2 23.5 24.3 25.3 22.1 22.5 23.2 24.3 20.8 21.1 21.9 23.0 19.6 19.9 20.7 21.7 S/T 0.70 0.63 0.50 0.4 0.71 0.63 0.51 0.4 1.00 0.66 0.53 0.4 1.00 0.68 0.55 0.4 1.00 0.70 0.57 0.4 1.00 1.00 0.62 0.5 AT 24 22 19 15 24 22 19 15 24 22 19 15 24 22 19 15 24 22 18 15 25 23 19 16 700 kW 1.43 1.43 1.42 1.4 1.58 1.58 1.57 1.6 1.74 1.74 1.74 1.8 1.92 1.92 1.92 1.9 2.12 2.12 2.12 2.1 2.36 2.36 2.36 2.4 Amps 4.9 4.9 4.9 5.0 5.6 5.6 5.6 5.6 6.4 6.4 6.3 6.4 7.2 7.2 7.2 7.2 8.1 8.1 8.1 8.1 9.2 9.2 9.2 9.2 HiPR 239 240 241 245.6 276 277 279 283.2 316 317 318 322.6 358 359 361 365.1 404 405 407 410.8 453 454 456 459.7 Lo PR 1 122 124 127 131.9 129 131 134 139.3 136 137 141 145.8 141 143 146 151.3 147 148 151 156.7 154 155 158 163.4 MBh 24.3 24.7 25.4 26.5 24.1 24.5 25.2 26.3 23.5 23.8 24.6 25.6 22.4 22.8 23.5 24.6 21.1 21.4 22.2 23.3 19.9 20.2 21.0 22.0 S/T 0.75 0.68 0.55 0.4 0.76 0.69 0.56 0.4 1.00 0.71 0.58 0.4 1.00 0.73 0.60 0.5 1.00 0.75 0.62 0.5 1.00 1.00 0.67 0.5 AT 23 21 18 14 23 21 18 14 23 21 18 14 23 21 18 14 23 21 17 14 24 22 18 15 75 795 kW 1.43 1.43 1.43 1.44 1.58 1.58 1.58 1.59 1.75 1.75 1.75 1.76 1.93 1.93 1.93 1.94 2.13 2.13 2.13 2.14 2.37 2.37 2.36 2.38 Amps 4.9 4.9 4.9 5.0 5.6 5.6 5.6 5.7 6.4 6.4 6.4 6.4 7.2 7.2 7.2 7.3 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.3 HiPR 241 242 243 247.5 278 279 281 285.1 318 319 320 324.6 360 361 363 367.0 406 407 409 412.8 455 456 457 461.6 Lo PR 124 125 128 133.6 131 133 136 141.0 138 139 142 147.5 143 145 148 153.0 149 150 153 158.4 155 157 160 165.1 MBh 24.8 25.1 25.9 27.0 24.6 24.9 25.6 26.7 24.0 24.3 25.0 26.1 22.9 23.2 23.9 25.0 21.6 21.9 22.6 23.7 20.4 20.7 21.4 22.5 S/T 0.79 0.72 0.59 0.5 1.00 0.72 0.60 0.5 1.00 0.75 0.62 0.5 1.00 0.77 0.64 0.5 1.00 0.79 0.66 0.5 1.00 1.00 0.71 0.6 AT 22 20 16 13 22 20 16 13 22 20 17 13 22 20 16 13 21 20 16 13 23 21 17 14 915 kW 1.44 1.44 1.44 1.4 1.59 1.59 1.59 1.6 1.76 1.76 1.75 1.8 1.94 1.94 1.93 1.9 2.14 2.14 2.14 2.1 2.38 2.38 2.37 2.4 Amps 5.0 5.0 5.0 5.0 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.3 7.3 7.2 7.3 8.2 8.2 8.2 8.2 9.3 9.3 9.2 9.3 HiPR 243 244 246 249.9 281 282 283 287.5 320 321 323 326.9 363 364 365 369.4 408 409 411 415.1 457 458 460 464.0 Lo PR 126 128 131 136.0 134 135 138 143.4 140 142 145 149.9 146 147 150 155.4 151 153 156 160.8 158 159 162 167.6 IDB: Entering Indoor Dry Bulb Temperature (2F) Shaded area reflects ACCA (TVA) conditions HI PR = PRESSURE AT LIQUID SERVICE VALVE, PSIG Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. MBH =NET TOTAL CAPACITY (1000 BTU/HR) LO PR = PRESSURE AT VAPOR SERVICE VALVE, PSIG kW = Total system power S/T = SENSIBLE TO TOTAL CAPACITY RATIO k n 0 O 0 Cz v 3 dip n O 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152E ENTERING INDOOR WET BULB TEMPERATURE D: MBh 24.2 24.5 25.2 26.3 23.9 24.3 25.0 26.1 23.3 23.7 24.4 25.5 22.2 22.6 23.3 24.4 20.9 21.3 22.0 23.1 19.7 20.1 20.8 21.9 S/T 1.00 0.75 0.62 0.5 1.00 0.75 0.62 0.5 1.00 0.78 0.65 0.5 1.00 0.80 0.67 0.5 1.00 1.00 0.69 0.6 1.00 1.00 0.74 0.6 AT 28 26 23 19 28 26 23 19 28 26 23 19 28 26 23 19 28 26 22 19 29 27 24 20 700 kW 1.43 1.43 1.42 1.4 1.58 1.58 1.57 1.6 1.74 1.74 1.74 1.8 1.92 1.92 1.92 1.9 2.13 2.12 2.12 2.1 2.36 2.36 2.36 2.4 Amps 4.9 4.9 4.9 5.0 5.6 5.6 5.6 5.6 6.4 6.4 6.3 6.4 7.2 7.2 7.2 7.2 8.1 8.1 8.1 8.1 9.2 9.2 9.2 9.2 Hi PR 239 240 242 246.0 277 278 279 283.7 316 317 319 323.1 359 360 361 365.5 404 405 407 411.3 453 454 456 460.1 Lo PR 123 124 127 132.4 130 132 135 139.8 137 138 141 146.3 142 144 147 151.8 147 149 152 157.2 154 156 159 164.0 MBh 24.5 24.8 25.5 26.6 24.2 24.6 25.3 26.4 23.6 24.0 24.7 25.8 22.5 22.9 23.6 24.7 21.2 21.6 22.3 23.4 20.0 20.4 21.1 22.2 S/T 1.00 0.80 0.67 0.5 1.00 0.81 0.68 0.5 1.00 0.83 0.70 0.6 1.00 0.85 0.72 0.6 1.00 1.00 0.74 0.6 1.00 1.00 0.79 0.7 AT 27 25 22 18 27 25 22 18 27 25 22 18 27 25 22 18 27 25 21 18 28 26 23 19 80 795 kW 1.44 1.43 1.43 1.44 1.58 1.58 1.58 1.59 1.75 1.75 1.75 1.76 1.93 1.93 1.93 1.94 2.13 2.13 2.13 2.14 2.37 2.37 2.37 2.38 Amps 5.0 4.9 4.9 5.0 5.6 5.6 5.6 5.7 6.4 6.4 6.4 6.4 7.2 7.2 7.2 7.3 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.3 Hi PR 241 242 244 248.0 279 280 281 285.6 318 319 321 325.0 361 362 363 367.4 406 407 409 413.2 455 456 458 462.0 Lo PR 124 126 129 134.1 132 133 136 141.5 138 140 143 148.0 144 145 148 153.5 149 151 154 158.9 156 157 160 165.7 MBh 24.9 25.3 26.0 27.1 24.7 25.1 25.8 26.9 24.1 24.4 25.1 26.2 23.0 23.3 24.1 25.2 21.7 22.0 22.7 23.8 20.5 20.8 21.5 22.6 S/T 1.00 0.84 0.71 0.6 1.00 0.84 0.71 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.83 0.7 AT 26 24 21 17 26 24 20 17 26 24 21 17 26 24 20 17 26 24 20 17 27 25 21 18 915 kW 1.44 1.44 1.44 1.5 1.59 1.59 1.59 1.6 1.76 1.76 1.76 1.8 1.94 1.94 1.94 1.9 2.14 2.14 2.14 2.1 2.38 2.38 2.37 2.4 Amps 5.0 5.0 5.0 5.0 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.3 7.3 7.2 7.3 8.2 8.2 8.2 8.2 9.3 9.3 9.2 9.3 Hi PR 243 245 246 250.3 281 282 284 288.0 321 322 323 327.4 363 364 366 369.8 409 410 411 415.6 458 459 460 464.4 Lo PR 127 128 131 136.5 134 136 139 144.0 141 142 145 150.5 146 148 151 156.0 152 153 156 161.3 158 160 163 168.1 MBh 24.6 24.9 25.6 26.7 24.4 24.7 25.4 26.5 23.7 24.1 24.8 25.9 22.6 23.0 23.7 24.8 21.3 21.7 22.4 23.5 20.1 20.5 21.2 22.3 S/T 1.00 0.84 0.71 0.6 1.00 0.85 0.72 0.6 1.00 1.00 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 1.00 0.7 AT 32 30 26 23 32 30 26 23 32 30 27 23 32 30 26 23 31 29 26 22 32 31 27 24 700 kW 1.43 1.43 1.43 1.4 1.58 1.58 1.58 1.6 1.75 1.75 1.74 1.8 1.93 1.93 1.92 1.9 2.13 2.13 2.12 2.1 2.36 2.36 2.36 2.4 Amps 4.9 4.9 4.9 5.0 5.6 5.6 5.6 5.7 6.4 6.4 6.4 6.4 7.2 7.2 7.2 7.2 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.2 Hi PR 240 241 243 247.2 278 279 281 284.8 317 318 320 324.2 360 361 362 366.6 406 407 408 412.4 454 455 457 461.2 Lo PR 124 126 129 134.2 132 133 136 141.6 138 140 143 148.1 144 145 148 153.6 149 151 154 159.0 156 157 161 165.8 MBh 24.9 25.2 25.9 27.0 24.7 25.0 25.7 26.8 24.0 24.4 25.1 26.2 22.9 23.3 24.0 25.1 21.6 22.0 22.7 23.8 20.4 20.8 21.5 22.6 S/T 1.00 0.90 0.77 0.6 1.00 0.90 0.77 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 1.00 0.8 AT 31 29 25 22 31 29 25 22 31 29 25 22 31 29 25 22 30 28 25 21 31 30 26 23 85 795 kW 1.44 1.44 1.43 1.45 1.59 1.59 1.58 1.59 1.75 1.75 1.75 1.76 1.93 1.93 1.93 1.94 2.14 2.13 2.13 2.14 2.37 2.37 2.37 2.38 Amps 5.0 5.0 4.9 5.0 5.6 5.6 5.6 5.7 6.4 6.4 6.4 6.4 7.2 7.2 7.2 7.3 8.2 8.2 8.1 8.2 9.2 9.2 9.2 9.3 Hi PR 242 243 245 249.1 280 281 283 286.7 319 320 322 326.1 362 363 364 368.6 407 408 410 414.3 456 457 459 463.2 Lo PR 126 128 131 135.9 134 135 138 143.4 140 142 145 149.9 146 147 150 155.4 151 152 156 160.7 158 159 162 167.5 MBh 25.3 25.7 26.4 27.5 25.1 25.5 26.2 27.3 24.5 24.8 25.5 26.6 23.4 23.8 24.5 25.6 22.1 22.4 23.2 24.2 20.9 21.2 21.9 23.0 S/T 1.00 0.93 0.80 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 1.00 0.8 AT 29 28 24 21 29 28 24 21 30 28 24 21 29 28 24 21 29 27 24 20 30 28 25 21 915 kW 1.45 1.44 1.44 1.5 1.59 1.59 1.59 1.6 1.76 1.76 1.76 1.8 1.94 1.94 1.94 1.9 2.14 2.14 2.14 2.2 2.38 2.38 2.38 2.4 Amps 5.0 5.0 5.0 5.0 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.3 7.3 7.3 7.3 8.2 8.2 8.2 8.2 9.3 9.3 9.3 9.3 Hi PR 245 246 247 251.5 282 283 285 289.1 322 323 324 328.5 364 365 367 370.9 410 411 413 416.7 459 460 461 465.5 Lo PR 129 130 133 138.4 136 137 141 145.8 142 144 147 152.3 148 149 153 157.8 153 155 158 163.2 160 162 165 169.9 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions HI PR = PRESSURE AT LIQUID SERVICE VALVE, PSIG Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. MBH = NETTOTAL CAPACITY (1000 BTU/HR) L0 PR = PRESSURE AT VAPOR SERVICE VALVE, PSIG kW = Total system power S/T = SENSIBLE TO TOTAL CAPACITY RATIO k n z Zj m O O r- z G) 0 0 0 0- 3 a 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 6591F 752F 852E I 959E 1052F 1152E ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 28.9 29.3 30.1 - 28.6 29.0 29.9 - 27.8 28.2 29.1 - 26.5 26.9 27.8 - 25.0 25.4 26.2 - 23.5 23.9 24.8 - S/T 0.58 0.51 0.38 0.59 0.51 0.38 0.61 0.54 0.41 0.63 0.56 0.42 1.00 0.58 0.45 1.00 0.63 0.50 AT 19 18 14 19 18 14 20 18 14 19 18 14 19 17 14 20 18 15 860 kW 1.69 1.69 1.69 1.87 1.87 1.86 2.06 2.06 2.06 2.27 2.27 2.27 2.50 2.50 2.50 2.78 2.78 2.78 Amps 5.7 5.7 5.7 6.5 6.5 6.5 7.4 7.4 7.4 8.4 8.4 8.4 9.4 9.4 9.4 10.7 10.7 10.7 Hi PR 236 237 238 273 274 276 312 313 315 354 355 356 399 400 402 447 448 450 Lo PR 1 121 122 125 128 130 133 134 136 139 140 141 145 145 147 150 152 153 157 MBh 29.3 29.7 30.5 29.0 29.4 30.3 28.3 28.7 29.5 27.0 27.4 28.2 25.4 25.8 26.6 23.9 24.3 25.2 S/T 0.65 0.57 0.44 0.66 0.58 0.45 0.68 0.61 0.47 0.70 0.62 0.49 1.00 0.65 0.51 1.00 0.70 0.56 AT 18 16 13 18 16 13 18 17 13 18 16 13 18 16 13 19 17 14 70 1000 kW 1.70 1.70 1.70 1.88 1.88 1.87 2.07 2.07 2.07 2.28 2.28 2.28 2.52 2.51 2.51 2.79 2.79 2.79 Amps 5.8 5.8 5.8 6.6 6.6 6.6 7.5 7.5 7.4 8.4 8.4 8.4 9.5 9.5 9.5 10.7 10.7 10.7 HiPR 238 239 241 275 276 278 314 315 317 356 357 359 401 402 404 450 451 452 Lo PR 123 124 127 130 132 135 136 138 141 142 143 147 147 149 152 154 155 159 MBh 29.6 30.0 30.9 29.3 29.7 30.6 28.6 29.0 29.9 27.3 27.7 28.6 2S.7 26.1 27.0 24.2 24.7 25.5 S/T 0.68 0.60 0.47 0.68 0.61 0.47 0.71 0.63 0.50 1.00 0.65 0.52 1.00 0.67 0.54 1.00 0.72 0.59 AT 18 16 12 17 16 12 18 16 13 17 16 12 17 15 12 18 17 13 1090 kW 1.71 1.71 1.71 1.88 1.88 1.88 2.08 2.08 2.07 2.29 2.29 2.28 2.52 2.52 2.52 2.80 2.79 2.79 Amps 5.8 5.8 5.8 6.6 6.6 6.6 7.5 7.5 7.5 8.4 8.4 8.4 9.5 9.5 9.5 10.8 10.8 10.8 HiPR 239 240 242 276 278 279 315 317 318 357 358 360 403 404 405 451 452 454 Lo PR 124 126 129 131 133 136 138 139 142 143 145 148 149 150 153 155 157 160 MBh 28.9 29.3 30.1 31.5 28.6 29.0 29.9 31.2 27.9 28.3 29.1 30.4 26.6 27.0 27.8 29.1 25.0 25.4 26.2 27.6 23.5 23.9 24.8 26.1 S/T 0.71 0.63 0.50 0.4 0.71 0.64 0.51 0.4 1.00 0.66 0.53 0.4 1.00 0.68 0.55 0.4 1.00 0.70 0.57 0.4 1.00 0.75 0.62 0.5 AT 23 22 18 15 23 21 18 15 24 22 18 15 23 21 18 15 23 21 18 14 24 22 19 16 860 kW 1.69 1.69 1.69 1.7 1.87 1.87 1.86 1.9 2.06 2.06 2.06 2.1 2.27 2.27 2.27 2.3 2.50 2.50 2.50 2.5 2.78 2.78 2.77 2.8 Amps 5.7 5.7 5.7 5.8 6.5 6.5 6.5 6.6 7.4 7.4 7.4 7.5 8.4 8.4 8.3 8.4 9.4 9.4 9.4 9.5 10.7 10.7 10.7 10.7 Hi PR 236 237 239 242.6 273 274 276 279.8 312 313 315 318.8 354 355 357 360.8 399 400 402 406.1 448 449 450 454.4 Lo PR 121 122 125 130.4 128 130 133 137.8 135 136 139 144.2 140 141 145 149.7 145 147 150 155.0 152 154 157 161.7 MBh 29.3 29.7 30.6 31.9 29.0 29.4 30.3 31.6 28.3 28.7 29.5 30.9 27.0 27.4 28.3 29.6 25.4 25.8 26.7 28.0 23.9 24.4 25.2 26.5 S/T 0.77 0.70 0.57 0.4 0.78 0.71 0.57 0.4 1.00 0.73 0.60 0.5 1.00 0.75 0.62 0.5 1.00 0.77 0.64 0.5 1.00 1.00 0.69 0.6 AT 22 20 17 14 22 20 17 13 22 21 17 14 22 20 17 13 22 20 17 13 23 21 18 14 75 1000 kW 1.70 1.70 1.70 1.71 1.88 1.88 1.87 1.89 2.07 2.07 2.07 2.08 2.28 2.28 2.28 2.29 2.51 2.51 2.51 2.52 2.79 2.79 2.78 2.80 Amps 5.8 5.8 5.8 5.8 6.6 6.6 6.6 6.6 7.5 7.5 7.4 7.5 8.4 8.4 8.4 8.5 9.5 9.5 9.5 9.5 10.7 10.7 10.7 10.8 Hi PR 238 239 241 244.9 275 276 278 282.1 314 315 317 321.1 356 357 359 363.1 402 403 404 408.3 450 451 453 456.6 Lo PR 123 124 127 132.4 130 132 135 139.8 137 138 141 146.2 142 143 147 151.7 147 149 152 157.0 154 155 159 163.7 MBh 29.6 30.0 30.9 32.2 29.4 29.8 30.6 31.9 28.6 29.0 29.9 31.2 27.3 27.7 28.6 29.9 25.7 26.1 27.0 28.3 24.3 24.7 25.5 26.9 S/T 0.80 0.73 0.59 0.5 0.81 0.73 0.60 0.5 1.00 0.76 0.63 0.5 1.00 0.78 0.64 0.5 1.00 0.80 0.67 0.5 1.00 1.00 0.72 0.6 AT 21 20 16 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 20 17 14 1090 kW 1.71 1.71 1.71 1.7 1.88 1.88 1.88 1.9 2.08 2.07 2.07 2.1 2.29 2.28 2.28 2.3 2.52 2.52 2.52 2.5 2.79 2.79 2.79 2.8 Amps 5.8 5.8 5.8 5.8 6.6 6.6 6.6 6.6 7.5 7.5 7.5 7.5 8.4 8.4 8.4 8.5 9.5 9.5 9.5 9.6 10.8 10.8 10.7 10.8 Hi PR 239 240 242 246.3 277 278 279 283.5 316 317 318 322.5 358 359 360 364.5 403 404 406 409.7 451 452 454 458.0 Lo PR 124 126 129 133.8 131 133 136 141.2 138 139 142 147.6 143 145 148 153.1 149 150 153 158.4 155 157 160 165.1 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW =Total system power k n 0 0 0 sZ v 3 dip 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 29.0 29.4 30.3 31.6 28.8 29.2 30.0 31.4 28.0 28.4 29.3 30.6 26.7 27.1 28.0 29.3 25.1 25.5 26.4 27.7 23.7 24.1 24.9 26.3 S/T 0.83 0.76 0.62 0.5 1.00 0.76 0.63 0.5 1.00 0.79 0.65 0.5 1.00 0.80 0.67 0.5 1.00 1.00 0.69 0.6 1.00 1.00 0.74 0.6 AT 27 25 22 19 27 25 22 19 27 26 22 19 27 25 22 19 27 25 22 18 28 26 23 20 860 kW 1.69 1.69 1.69 1.7 1.87 1.87 1.86 1.9 2.06 2.06 2.06 2.1 2.27 2.27 2.27 2.3 2.50 2.50 2.50 2.5 2.78 2.78 2.77 2.8 Amps 5.7 5.7 5.7 5.8 6.5 6.5 6.5 6.6 7.4 7.4 7.4 7.5 8.4 8.4 8.4 8.4 9.4 9.4 9.4 9.5 10.7 10.7 10.7 10.7 Hi PR 236 237 239 243.0 273 274 276 280.3 312 313 315 319.3 354 355 357 361.2 400 401 402 406.5 448 449 451 454.8 Lo PR 121 123 126 131.0 129 130 133 138.3 135 137 140 144.8 141 142 145 150.2 146 147 150 155.6 153 154 157 162.3 MBh 29.4 29.8 30.7 32.0 29.2 29.6 30.5 31.8 28.4 28.8 29.7 31.0 27.1 27.5 28.4 29.7 25.5 26.0 26.8 28.1 24.1 24.5 25.4 26.7 S/T 1.00 0.82 0.69 0.6 1.00 0.83 0.70 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.81 0.7 AT 26 24 21 17 26 24 21 17 26 24 21 18 26 24 21 17 26 24 21 17 27 25 22 18 80 1000 kW 1.70 1.70 1.70 1.71 1.88 1.88 1.87 1.89 2.07 2.07 2.07 2.08 2.28 2.28 2.28 2.29 2.51 2.51 2.51 2.52 2.79 2.79 2.79 2.80 Amps 5.8 5.8 5.8 5.8 6.6 6.6 6.6 6.6 7.5 7.5 7.4 7.5 8.4 8.4 8.4 8.5 9.5 9.5 9.5 9.5 10.7 10.7 10.7 10.8 Hi PR 239 240 241 245.3 276 277 278 282.5 315 316 317 321.5 357 358 359 363.5 402 403 405 408.8 450 451 453 457.1 Lo PR 123 125 128 133.0 131 132 135 140.3 137 139 142 146.8 142 144 147 152.2 148 149 152 157.6 155 156 159 164.3 MBh 29.8 30.2 31.0 32.3 29.5 29.9 30.8 32.1 28.7 29.2 30.0 31.3 27.4 27.9 28.7 30.0 25.9 26.3 27.1 28.5 24.4 24.8 2S.7 27.0 S/T 1.00 0.85 0.72 0.6 1.00 0.86 0.72 0.6 1.00 0.88 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.6 1.00 1.00 0.84 0.7 AT 25 24 20 17 25 24 20 17 26 24 20 17 25 24 20 17 25 23 20 17 26 24 21 18 logo kW 1.71 1.71 1.71 1.7 1.88 1.88 1.88 1.9 2.08 2.08 2.07 2.1 2.29 2.29 2.28 2.3 2.52 2.52 2.52 2.5 2.79 2.79 2.79 2.8 Amps 5.8 5.8 5.8 5.8 6.6 6.6 6.6 6.6 7.5 7.5 7.5 7.5 8.4 8.4 8.4 8.5 9.5 9.5 9.5 9.6 10.8 10.8 10.8 10.8 Hi PR 240 241 243 246.7 277 278 280 283.9 316 317 319 322.9 358 359 361 364.9 403 404 406 410.2 452 453 454 458.5 Lo PR 1 125 126 129 134.4 132 133 137 141.7 138 140 143 148.2 144 145 148 153.6 149 151 154 159.0 156 157 160 165.6 MBh 29.5 29.9 30.8 32.1 29.2 29.7 30.5 31.8 28.5 28.9 29.8 31.1 27.2 27.6 28.5 29.8 25.6 26.0 26.9 28.2 24.2 24.6 25.4 26.7 S/T 1.00 0.85 0.72 0.6 1.00 0.86 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 1.00 0.7 AT 31 29 26 22 31 29 26 22 31 29 26 22 31 29 26 22 30 29 25 22 32 30 26 23 860 kW 1.70 1.70 1.69 1.7 1.87 1.87 1.87 1.9 2.06 2.06 2.06 2.1 2.27 2.27 2.27 2.3 2.51 2.51 2.50 2.5 2.78 2.78 2.78 2.8 Amps 5.8 5.7 5.7 5.8 6.5 6.5 6.5 6.6 7.4 7.4 7.4 7.5 8.4 8.4 8.4 8.4 9.5 9.5 9.4 9.5 10.7 10.7 10.7 10.8 Hi PR 237 238 240 244.2 275 276 277 281.4 314 315 316 320.4 356 357 358 362.4 401 402 404 407.6 449 450 452 455.9 Lo PR 123 125 128 132.8 130 132 135 140.2 137 138 141 146.6 142 144 147 152.0 148 149 152 157.4 154 156 159 164.1 MBh 29.9 30.3 31.2 32.5 29.7 30.1 30.9 32.3 28.9 29.3 30.2 31.5 27.6 28.0 28.9 30.2 26.0 26.4 27.3 28.6 24.6 25.0 25.9 27.2 S/T 1.00 0.92 0.79 0.7 1.00 0.93 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 1.00 0.8 AT 30 28 24 21 29 28 24 21 30 28 25 21 29 28 24 21 29 27 24 21 30 29 25 22 85 1000 kW 1.71 1.71 1.70 1.72 1.88 1.88 1.88 1.89 2.07 2.07 2.07 2.08 2.28 2.28 2.28 2.29 2.52 2.52 2.51 2.53 2.79 2.79 2.79 2.80 Amps 5.8 5.8 5.8 5.8 6.6 6.6 6.6 6.6 7.5 7.5 7.5 7.5 8.4 8.4 8.4 8.5 9.5 9.5 9.5 9.5 10.8 10.8 10.7 10.8 Hi PR 240 241 242 246.4 277 278 280 283.6 316 317 319 322.6 358 359 361 364.6 403 404 406 409.9 451 452 454 458.2 Lo PR 125 127 130 134.8 132 134 137 142.1 139 140 143 148.6 144 146 149 154.0 150 151 154 159.4 156 158 161 166.1 MBh 30.2 30.7 31.5 32.8 30.0 30.4 31.3 32.6 29.2 29.6 30.5 31.8 27.9 28.3 29.2 30.5 26.3 26.8 27.6 28.9 24.9 25.3 26.2 27.5 S/T 1.00 0.95 0.82 0.7 1.00 0.95 0.82 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 1.00 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 21 29 27 24 20 29 27 23 20 30 28 25 21 1090 kW 1.71 1.71 1.71 1.7 1.89 1.89 1.88 1.9 2.08 2.08 2.08 2.1 2.29 2.29 2.29 2.3 2.52 2.52 2.52 2.5 2.80 2.80 2.79 2.8 Amps 5.8 5.8 5.8 5.9 6.6 6.6 6.6 6.7 7.5 7.5 7.5 7.5 8.5 8.5 8.4 8.5 9.5 9.5 9.5 9.6 10.8 10.8 10.8 10.8 Hi PR 241 242 244 247.8 278 279 281 285.0 317 318 320 324.0 359 360 362 366.0 404 406 407 411.3 453 454 455 459.6 Lo PR 126 128 131 136.2 134 135 138 143.5 140 142 145 150.0 146 147 150 155.4 151 153 156 160.8 158 159 162 167.5 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n 0 n 0 0 0 sZ 3 a 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052E 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 34.8 35.3 36.3 - 34.4 34.9 36.0 - 33.5 34.0 35.1 - 32.0 32.5 33.5 - 30.1 30.6 31.6 - 28.3 28.8 29.9 - S/T 0.59 0.52 0.38 0.60 0.52 0.39 0.62 0.55 0.41 0.64 0.57 0.43 1.00 0.59 0.46 1.00 0.64 0.51 AT 21 19 15 21 19 15 21 19 16 21 19 15 21 19 15 22 20 16 990 kW 2.05 2.05 2.04 2.27 2.27 2.27 2.52 2.52 2.51 2.79 2.79 2.78 3.09 3.09 3.08 3.44 3.44 3.43 Amps 7.1 7.1 7.0 8.1 8.1 8.1 9.2 9.2 9.2 10.5 10.4 10.4 11.8 11.8 11.8 13.4 13.4 13.4 HiPR 247 248 249 286 287 288 326 327 329 370 371 373 418 419 421 468 469 471 Lo PR 1 121 123 126 129 130 133 135 137 140 141 142 145 146 148 151 153 154 157 MBh 35.3 35.7 36.8 34.9 35.4 36.5 34.0 34.5 35.6 32.5 33.0 34.0 30.6 31.0 32.1 28.8 29.3 30.3 S/T 0.66 0.58 0.45 0.66 0.59 0.45 0.69 0.61 0.48 0.71 0.63 0.50 1.00 0.65 0.52 1.00 0.71 0.57 AT 20 18 14 20 18 14 20 18 14 20 18 14 19 17 14 20 19 15 70 1145 kW 2.06 2.06 2.06 2.28 2.28 2.28 2.53 2.53 2.53 2.80 2.80 2.79 3.10 3.10 3.09 3.45 3.4S 3.45 Amps 7.1 7.1 7.1 8.1 8.1 8.1 9.3 9.3 9.3 10.5 10.5 10.5 11.9 11.9 11.9 13.5 13.5 13.5 HiPR 249 250 252 288 289 291 329 330 332 373 374 375 420 421 423 471 472 473 Lo PR 123 125 128 131 132 135 137 139 142 143 144 147 148 149 153 155 156 159 MBh 35.9 36.4 37.5 35.6 36.1 37.2 34.7 35.2 36.2 33.2 33.6 34.7 31.2 31.7 32.8 29.5 30.0 31.0 S/T 0.70 0.62 0.49 0.70 0.63 0.49 0.73 0.65 0.52 1.00 0.67 0.54 1.00 0.69 0.56 1.00 0.74 0.61 AT 18 17 13 18 16 13 19 17 13 18 16 13 18 16 13 19 17 14 1320 kW 2.07 2.07 2.07 2.29 2.29 2.29 2.54 2.54 2.54 2.81 2.81 2.81 3.11 3.11 3.11 3.46 3.46 3.46 Amps 72 72 72 8.2 8.2 8.2 9.3 9.3 9.3 10.6 10.6 10.5 11.9 11.9 11.9 13.6 13.5 13.5 HiPR 251 253 254 290 291 293 331 332 334 375 376 378 423 424 425 473 474 476 Lo PR 126 127 130 133 135 138 140 141 144 145 147 150 150 152 155 157 159 162 MBh 34.8 35.3 36.3 37.9 34.5 35.0 36.0 37.6 33.6 34.1 35.1 36.7 32.0 32.5 33.5 35.1 30.1 30.6 31.6 33.2 28.3 28.8 29.9 31.5 S/T 0.72 0.64 0.51 0.4 0.73 0.65 0.52 0.4 1.00 0.68 0.54 0.4 1.00 0.69 0.56 0.4 1.00 0.72 0.58 0.4 1.00 0.77 0.63 0.5 AT 25 23 20 16 25 23 20 16 25 23 20 16 25 23 20 16 25 23 19 16 26 24 20 17 990 kW 2.05 2.05 2.04 2.1 2.27 2.27 2.26 2.3 2.52 2.52 2.51 2.5 2.79 2.78 2.78 2.8 3.09 3.08 3.08 3.1 3.44 3.44 3.43 3.4 Amps 7.1 7.1 7.0 7.1 8.1 8.1 8.1 8.1 9.2 9.2 9.2 9.3 10.5 10.4 10.4 10.5 11.8 11.8 11.8 11.9 13.4 13.4 13.4 13.5 HiPR 247 248 250 254.0 286 287 289 292.9 327 328 329 333.8 371 372 373 377.7 418 419 421 425.1 469 470 471 475.6 Lo PR 121 123 126 131.1 129 130 133 138.5 135 137 140 145.0 141 142 145 150.4 146 148 151 155.8 153 154 157 162.5 MBh 35.3 35.8 36.8 38.4 35.0 35.5 36.5 38.1 34.1 34.5 35.6 37.2 32.5 33.0 34.0 35.6 30.6 31.1 32.1 33.7 28.8 29.3 30.4 32.0 S/T 0.79 0.71 0.58 0.4 0.79 0.72 0.58 0.4 1.00 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 0.78 0.65 0.5 1.00 1.00 0.70 0.6 AT 24 22 18 15 24 22 18 15 24 22 19 15 24 22 18 15 23 22 18 14 25 23 19 15 75 1145 kW 2.06 2.06 2.05 2.07 2.28 2.28 2.28 2.29 2.53 2.53 2.52 2.54 2.80 2.80 2.79 2.81 3.10 3.10 3.09 3.11 3.45 3.45 3.45 3.46 Amps 7.1 7.1 7.1 7.2 8.1 8.1 8.1 8.2 9.3 9.3 9.3 9.3 10.5 10.5 10.5 10.6 11.9 11.9 11.9 11.9 13.5 13.5 13.5 13.5 Hi PR 249 250 252 256.3 288 289 291 295.2 329 330 332 336.0 373 374 376 380.0 420 421 423 427.3 471 472 474 477.9 Lo PR 123 125 128 133.0 131 132 135 140.4 137 139 142 146.9 143 1" 147 152.4 148 149 153 157.7 155 156 159 164.5 MBh 36.0 36.4 37.5 39.1 35.6 36.1 37.2 38.8 34.7 35.2 36.3 37.9 33.2 33.7 34.7 36.3 31.3 31.8 32.8 34.4 29.5 30.0 31.1 32.6 S/T 0.82 0.75 0.61 0.5 0.83 0.75 0.62 0.5 1.00 0.78 0.64 0.5 1.00 0.80 0.66 0.5 1.00 0.82 0.69 0.5 1.00 1.00 0.74 0.6 AT 23 21 17 13 23 21 17 13 23 21 17 14 23 21 17 13 22 20 17 13 24 22 18 14 1320 kW 2.07 2.07 2.07 2.1 2.29 2.29 2.29 2.3 2.54 2.54 2.54 2.6 2.81 2.81 2.80 2.8 3.11 3.11 3.10 3.1 3.46 3.46 3.46 3.5 Amps 72 72 72 72 82 8.2 8.2 8.2 9.3 9.3 9.3 9.4 10.6 10.6 10.5 10.6 11.9 11.9 11.9 12.0 13.5 13.5 13.5 13.6 HiPR 252 253 254 258.8 291 292 293 297.7 331 332 334 338.5 375 376 378 382.5 423 424 426 429.8 473 474 476 480.4 Lo PR 126 127 130 135.5 133 135 138 142.9 140 141 144 149.3 145 147 150 154.8 150 152 155 160.2 157 159 162 166.9 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions HI PR = PRESSURE AT LIQUID SERVICE VALVE, PSIG Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. MBH = NETTOTAL CAPACITY (loon BTU/HR) LO PR = PRESSURE AT VAPOR SERVICE VALVE, PSIG kW = Total system power S/T = SENSIBLE To TOTAL CAPACITY RATIO k n 0 0 0 Q v 3 dip 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 35.0 35.5 36.5 38.1 34.6 35.1 36.2 37.8 33.7 34.2 35.3 36.9 32.2 32.7 33.7 35.3 30.3 30.8 31.8 33.4 28.5 29.0 30.1 31.6 S/T 0.84 0.77 0.63 0.5 1.00 0.77 0.64 0.5 1.00 0.80 0.67 0.5 1.00 0.82 0.68 0.5 1.00 1.00 0.71 0.6 1.00 1.00 0.76 0.6 AT 29 27 24 20 29 27 24 20 30 28 24 20 29 27 24 20 29 27 24 20 30 28 25 21 990 kW 2.05 2.05 2.04 2.1 2.27 2.27 2.26 2.3 2.52 2.52 2.51 2.5 2.79 2.79 2.78 2.8 3.09 3.09 3.08 3.1 3.44 3.44 3.43 3.5 Amps 7.1 7.1 7.0 7.1 8.1 8.1 8.1 8.1 9.2 9.2 9.2 9.3 10.5 10.4 10.4 10.5 11.8 11.8 11.8 11.9 13.4 13.4 13.4 13.5 Hi PR 247 248 250 254.4 286 287 289 293.4 327 328 330 334.2 371 372 374 378.1 418 419 421 425.5 469 470 472 476.1 Lo PR 122 123 126 131.6 129 131 134 139.0 136 137 140 145.5 141 143 146 151.0 147 148 151 156.3 153 155 158 163.1 MBh 35.5 35.9 37.0 38.6 35.1 35.6 36.7 38.3 34.2 34.7 35.8 37.4 32.7 33.2 34.2 35.8 30.8 31.2 32.3 33.9 29.0 29.5 30.5 32.1 S/T 1.00 0.83 0.70 0.6 1.00 0.84 0.71 0.6 1.00 0.86 0.73 0.6 1.00 0.88 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.82 0.7 AT 28 26 23 19 28 26 23 19 28 26 23 19 28 26 22 19 28 26 22 19 29 27 23 20 80 1145 kW 2.06 2.06 2.05 2.07 2.28 2.28 2.28 2.29 2.53 2.53 2.53 2.54 2.80 2.80 2.79 2.81 3.10 3.10 3.09 3.11 3.45 3.45 3.45 3.46 Amps 7.1 7.1 7.1 7.2 8.1 8.1 8.1 8.2 9.3 9.3 9.3 9.3 10.5 10.5 10.5 10.6 11.9 11.9 11.9 11.9 13.5 13.5 13.5 13.6 Hi PR 250 251 252 256.7 289 290 291 295.7 329 330 332 336.5 373 374 376 380.4 421 422 423 427.8 471 472 474 478.4 LO PR 124 125 128 133.6 131 133 136 141.0 138 139 142 147.4 143 145 148 152.9 149 150 153 158.3 155 157 160 165.0 MBh 36.1 36.6 37.7 39.3 35.8 36.3 37.4 38.9 34.9 35.4 36.4 38.0 33.4 33.8 34.9 36.5 31.4 31.9 33.0 34.6 29.7 30.2 31.2 32.8 S/T 1.00 0.87 0.74 0.6 1.00 0.88 0.74 0.6 1.00 0.90 0.77 0.6 1.00 1.00 0.79 0.6 1.00 1.00 0.81 0.7 1.00 1.00 0.86 0.7 AT 27 25 21 18 27 25 21 18 27 25 22 18 27 25 21 18 27 25 21 17 28 26 22 19 1320 kW 2.07 2.07 2.07 2.1 2.29 2.29 2.29 2.3 2.54 2.54 2.54 2.6 2.81 2.81 2.81 2.8 3.11 3.11 3.11 3.1 3.46 3.46 3.46 3.5 Amps 72 72 72 72 8.2 8.2 8.2 8.3 9.3 9.3 9.3 9.4 10.6 10.6 10.5 10.6 11.9 11.9 11.9 12.0 13.6 13.5 13.5 13.6 Hi PR 252 253 255 259.2 291 292 294 298.2 332 333 335 339.0 376 377 379 382.9 423 424 426 430.3 474 475 477 480.9 Lo PR 1 126 128 131 136.0 134 135 138 143.4 140 142 145 149.9 146 147 150 155.3 151 152 156 160.7 158 159 162 167.4 MBh 35.5 36.0 37.1 38.7 35.2 35.7 36.8 38.4 34.3 34.8 35.9 37.4 32.8 33.3 34.3 35.9 30.9 31.3 32.4 34.0 29.1 29.6 30.6 32.2 S/T 1.00 0.87 0.73 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.81 0.7 1.00 1.00 1.00 0.7 AT 33 31 28 24 33 31 28 24 33 31 28 24 33 31 28 24 33 31 27 24 34 32 28 25 990 kW 2.05 2.05 2.05 2.1 2.27 2.27 2.27 2.3 2.52 2.52 2.52 2.5 2.79 2.79 2.79 2.8 3.09 3.09 3.09 3.1 3.44 3.44 3.44 3.5 Amps 7.1 7.1 7.1 7.1 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.3 10.5 10.5 10.5 10.5 11.8 11.8 11.8 11.9 13.5 13.5 13.4 13.5 Hi PR 248 250 251 255.6 287 289 290 294.6 328 329 331 335.4 372 373 375 379.3 420 421 422 426.7 470 471 473 477.2 Lo PR 124 125 128 133.5 131 133 136 140.8 138 139 142 147.3 143 145 148 152.8 148 150 153 158.2 155 157 160 164.9 MBh 36.0 36.5 37.6 39.2 35.7 36.2 37.3 38.8 34.8 35.3 36.3 37.9 33.3 33.7 34.8 36.4 31.3 31.8 32.9 34.5 29.6 30.1 31.1 32.7 S/T 1.00 0.93 0.80 0.7 1.00 0.94 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 1.00 0.8 AT 32 30 26 23 32 30 26 23 32 30 27 23 32 30 26 23 32 30 26 22 33 31 27 23 85 1145 kW 2.06 2.06 2.06 2.08 2.29 2.29 2.28 2.30 2.54 2.53 2.53 2.55 2.80 2.80 2.80 2.82 3.10 3.10 3.10 3.12 3.46 3.45 3.45 3.47 Amps 7.2 7.1 7.1 7.2 8.2 8.2 8.1 8.2 9.3 9.3 9.3 9.4 10.5 10.5 10.5 10.6 11.9 11.9 11.9 12.0 13.5 13.5 13.5 13.6 Hi PR 251 252 254 257.9 290 291 293 296.8 331 332 333 337.6 374 376 377 381.6 422 423 425 429.0 472 473 475 479.5 Lo PR 126 127 130 135.4 133 135 138 142.8 139 141 144 149.2 145 146 150 154.7 150 152 155 160.1 157 159 162 166.8 MBh 36.7 37.2 38.3 39.8 36.4 36.9 37.9 39.5 35.5 36.0 37.0 38.6 33.9 34.4 35.5 37.1 32.0 32.5 33.6 35.1 30.3 30.8 31.8 33.4 S/T 1.00 0.97 0.84 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 0.91 0.8 1.00 1.00 1.00 0.8 AT 31 29 25 21 31 29 25 21 31 29 25 22 31 29 25 21 30 28 25 21 32 30 26 22 1320 kW 2.08 2.07 2.07 2.1 2.30 2.30 2.29 2.3 2.55 2.55 2.54 2.6 2.82 2.81 2.81 2.8 3.12 3.11 3.11 3.1 3.47 3.47 3.46 3.5 Amps 72 72 72 7.3 8.2 8.2 8.2 8.3 9.4 9.3 9.3 9.4 10.6 10.6 10.6 10.6 12.0 12.0 11.9 12.0 13.6 13.6 13.5 13.6 Hi PR 253 254 256 260.4 292 293 295 299.3 333 334 336 340.1 377 378 380 384.1 424 425 427 431.5 475 476 478 482.0 Lo PR 128 130 133 137.8 135 137 140 145.2 142 143 147 151.7 147 149 152 157.2 153 154 157 162.5 159 161 164 169.3 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions MBH = NET TOTAL CAPACITY (1000 BTU/HR) S/T = SENSIBLE TO TOTAL CAPACITY RATIO HI PR = PRESSURE AT LIQUID SERVICE VALVE, PSIG LID PR = PRESSURE AT VAPOR SERVICE VALVE, PSIG Amps = outdoor unit amps (comp.+fan) kW = Total system power k 0 n 0 0 0 :Z 3 a 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 40.7 41.3 42.5 - 40.3 40.9 42.1 - 39.3 39.8 41.0 - 37.4 38.0 39.2 - 35.2 35.8 37.0 - 33.2 33.7 34.9 - S/T 0.61 0.54 0.40 0.62 0.54 0.40 0.64 0.57 0.43 0.66 0.59 0.45 0.69 0.61 0.47 1.00 0.66 0.52 AT 19 18 14 19 18 14 20 18 14 19 18 14 19 17 14 20 18 15 1220 kW 2.38 2.38 2.38 2.63 2.63 2.63 2.91 2.91 2.91 3.22 3.21 3.21 3.55 3.55 3.55 3.95 3.95 3.94 Amps 8.1 8.1 8.1 9.2 9.2 9.2 10.5 10.5 10.5 11.9 11.9 11.9 13.4 13.4 13.4 15.3 15.2 15.2 HiPR 237 238 239 274 275 277 313 314 316 355 356 358 401 402 403 449 450 452 Lo PR 1 119 120 123 126 128 131 132 134 137 138 139 142 143 144 147 150 151 154 MBh 41.2 41.8 43.0 40.9 41.4 42.7 39.8 40.4 41.6 38.0 38.5 39.8 35.7 36.3 37.5 33.7 34.3 35.5 S/T 0.68 0.60 0.46 0.68 0.60 0.47 0.71 0.63 0.49 0.73 0.65 0.51 1.00 0.67 0.53 1.00 0.72 0.59 AT 18 16 13 18 16 13 18 17 13 18 16 13 18 16 13 19 17 14 70 1400 kW 2.40 2.40 2.39 2.65 2.65 2.64 2.93 2.92 2.92 3.23 3.23 3.22 3.57 3.57 3.56 3.96 3.96 3.96 Amps 8.1 8.1 8.1 9.3 9.3 9.3 10.6 10.6 10.5 12.0 11.9 11.9 13.5 13.5 13.5 15.3 15.3 15.3 HiPR 239 240 241 276 277 279 315 316 318 357 358 360 403 404 405 451 452 454 Lo PR 121 122 125 128 129 132 134 136 139 140 141 144 145 146 149 151 153 156 MBh 41.7 42.3 43.5 41.3 41.9 43.1 40.3 40.8 42.1 38.4 39.0 40.2 36.2 36.8 38.0 34.2 34.7 36.0 S/T 0.70 0.63 0.49 0.71 0.63 0.49 0.73 0.66 0.52 0.75 0.68 0.54 1.00 0.70 0.56 1.00 0.75 0.61 AT 18 16 12 18 16 12 18 16 13 17 16 12 17 15 12 18 17 13 1530 kW 2.41 2.40 2.40 2.66 2.65 2.65 2.94 2.93 2.93 3.24 3.24 3.23 3.58 3.57 3.57 3.97 3.97 3.97 Amps 8.2 8.2 8.2 9.3 9.3 9.3 10.6 10.6 10.6 12.0 12.0 12.0 13.5 13.5 13.5 15.4 15.3 15.3 HiPR 240 241 243 277 278 280 317 318 319 359 360 361 404 405 407 453 454 455 Lo PR 122 123 127 129 131 134 136 137 140 141 142 145 146 148 151 153 154 157 MBh 40.7 41.3 42.5 44.4 40.3 40.9 42.1 44.0 39.3 39.9 41.1 42.9 37.4 38.0 39.2 41.1 35.2 35.8 37.0 38.9 33.2 33.8 35.0 36.8 S/T 0.74 0.67 0.53 0.4 0.75 0.67 0.53 0.4 0.77 0.70 0.56 0.4 1.00 0.72 0.58 0.4 1.00 0.74 0.60 0.5 1.00 0.79 0.65 0.5 AT 23 22 18 15 23 21 18 15 23 22 18 15 23 21 18 15 23 21 18 14 24 22 19 16 1220 kW 2.38 2.38 2.38 2.4 2.63 2.63 2.63 2.6 2.91 2.91 2.91 2.9 3.21 3.21 3.21 3.2 3.55 3.55 3.55 3.6 3.95 3.95 3.94 4.0 Amps 8.1 8.1 8.0 8.1 9.2 9.2 9.2 9.3 10.5 10.5 10.5 10.6 11.9 11.9 11.9 11.9 13.4 13.4 13.4 13.5 15.2 15.2 15.2 15.3 Hi PR 237 238 239 243.6 274 275 277 280.9 313 314 316 320.0 355 356 358 362.1 401 402 403 407.6 449 450 452 456.0 Lo PR 119 120 123 128.4 126 128 131 135.6 132 134 137 142.0 138 139 142 147.3 143 144 148 152.6 150 151 154 159.2 MBh 41.3 41.8 43.0 44.9 40.9 41.5 42.7 44.5 39.8 40.4 41.6 43.5 38.0 38.6 39.8 41.6 35.8 36.3 37.6 39.4 33.7 34.3 35.5 37.4 S/T 0.81 0.73 0.59 0.4 0.81 0.74 0.60 0.5 1.00 0.76 0.62 0.5 1.00 0.78 0.64 0.5 1.00 0.80 0.67 0.5 1.00 0.86 0.72 0.6 AT 22 20 17 14 22 20 17 14 22 21 17 14 22 20 17 14 22 20 17 13 23 21 18 14 75 1400 kW 2.40 2.39 2.39 2.41 2.65 2.64 2.64 2.66 2.93 2.92 2.92 2.94 3.23 3.23 3.22 3.24 3.57 3.56 3.56 3.58 3.96 3.96 3.96 3.97 Amps 8.1 8.1 8.1 8.2 9.3 9.3 9.3 9.3 10.6 10.6 10.5 10.6 11.9 11.9 11.9 12.0 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 HiPR 239 240 242 245.6 276 277 279 283.0 315 316 318 322.1 357 358 360 364.2 403 404 406 409.6 451 452 454 458.1 Lo PR 121 122 125 130.2 128 129 132 137.4 134 136 139 143.8 140 141 144 149.1 145 146 149 154.4 151 153 156 160.9 MBh 41.7 42.3 43.5 45.4 41.4 41.9 43.1 45.0 40.3 40.9 42.1 43.9 38.5 39.0 40.3 42.1 36.2 36.8 38.0 39.9 34.2 34.8 36.0 37.8 S/T 0.83 0.76 0.62 0.5 0.84 0.76 0.63 0.5 1.00 0.79 0.65 0.5 1.00 0.81 0.67 0.5 1.00 0.83 0.69 0.5 1.00 0.88 0.75 0.6 AT 21 20 16 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 21 17 14 1530 kW 2.40 2.40 2.40 2.4 2.65 2.65 2.65 2.7 2.93 2.93 2.93 2.9 3.24 3.23 3.23 3.2 3.57 3.57 3.57 3.6 3.97 3.97 3.96 4.0 Amps 8.2 8.2 8.1 8.2 9.3 9.3 9.3 9.4 10.6 10.6 10.6 10.7 12.0 12.0 12.0 12.0 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 HiPR 240 241 243 247.1 278 279 280 284.4 317 318 319 323.5 359 360 362 365.7 404 405 407 411.1 453 454 455 459.5 Lo PR 122 124 127 131.6 129 131 134 138.8 136 137 140 145.2 141 142 145 150.5 146 148 151 155.8 153 154 157 162.4 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n 0 0 0 Q v 3 oar' n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 40.9 41.5 42.7 44.6 40.6 41.1 42.3 44.2 39.5 40.1 41.3 43.1 37.7 38.2 39.5 41.3 35.4 36.0 37.2 39.1 33.4 34.0 35.2 37.0 S/T 0.87 0.79 0.66 0.5 1.00 0.80 0.66 0.5 1.00 0.82 0.69 0.5 1.00 0.84 0.71 0.6 1.00 0.87 0.73 0.6 1.00 1.00 0.78 0.6 AT 27 25 22 19 27 25 22 19 27 26 22 19 27 25 22 19 27 25 22 18 28 26 23 19 1220 kW 2.38 2.38 2.38 2.4 2.63 2.63 2.63 2.6 2.91 2.91 2.91 2.9 3.22 3.21 3.21 3.2 3.55 3.55 3.55 3.6 3.95 3.95 3.94 4.0 Amps 8.1 8.1 8.1 8.1 9.2 9.2 9.2 9.3 10.5 10.5 10.5 10.6 11.9 11.9 11.9 11.9 13.4 13.4 13.4 13.5 15.3 15.2 15.2 15.3 Hi PR 237 238 240 244.0 275 276 277 281.3 314 315 316 320.5 356 357 358 362.6 401 402 404 408.0 450 451 452 456.5 Lo PR 119 121 124 128.9 127 128 131 136.2 133 134 137 142.5 138 140 143 147.8 144 145 148 153.1 150 152 155 159.7 MBh 41.5 42.0 43.3 45.1 41.1 41.7 42.9 44.7 40.0 40.6 41.8 43.7 38.2 38.8 40.0 41.9 36.0 36.5 37.8 39.6 33.9 34.5 35.7 37.6 S/T 0.93 0.86 0.72 0.6 1.00 0.86 0.73 0.6 1.00 0.89 0.75 0.6 1.00 0.91 0.77 0.6 1.00 1.00 0.79 0.6 1.00 1.00 0.84 0.7 AT 26 24 21 18 26 24 21 18 26 25 21 18 26 24 21 17 26 24 21 17 27 25 22 18 80 1400 kW 2.40 2.39 2.39 2.41 2.65 2.65 2.64 2.66 2.93 2.92 2.92 2.94 3.23 3.23 3.22 3.24 3.57 3.56 3.56 3.58 3.96 3.96 3.96 3.98 Amps 8.1 8.1 8.1 8.2 9.3 9.3 9.3 9.3 10.6 10.6 10.5 10.6 12.0 11.9 11.9 12.0 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 Hi PR 239 240 242 246.1 277 278 279 283.4 316 317 318 322.5 358 359 361 364.7 403 404 406 410.1 452 453 454 458.5 Lo PR 121 123 126 130.7 128 130 133 138.0 135 136 139 144.3 140 142 145 149.6 145 147 150 154.9 152 153 156 161.5 MBh 41.9 42.5 43.7 45.6 41.6 42.1 43.4 45.2 40.5 41.1 42.3 44.2 38.7 39.2 40.5 42.3 36.4 37.0 38.2 40.1 34.4 35.0 36.2 38.0 S/T 1.00 0.88 0.75 0.6 1.00 0.89 0.75 0.6 1.00 0.92 0.78 0.6 1.00 0.94 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.87 0.7 AT 25 24 20 17 25 24 20 17 26 24 21 17 25 24 20 17 25 23 20 17 26 24 21 18 1530 kW 2.41 2.40 2.40 2.4 2.66 2.65 2.65 2.7 2.93 2.93 2.93 2.9 3.24 3.24 3.23 3.2 3.57 3.57 3.57 3.6 3.97 3.97 3.97 4.0 Amps 8.2 8.2 8.2 8.2 9.3 9.3 9.3 9.4 10.6 10.6 10.6 10.7 12.0 12.0 12.0 12.0 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 Hi PR 241 242 243 247.5 278 279 281 284.9 317 318 320 324.0 359 360 362 366.1 405 406 407 411.5 453 454 456 460.0 Lo PR 123 124 127 132.1 130 131 134 139.4 136 138 141 145.7 141 143 146 151.1 147 148 151 156.3 153 155 158 162.9 MBh 41.6 42.2 43.4 45.2 41.2 41.8 43.0 44.9 40.2 40.7 42.0 43.8 38.3 38.9 40.1 42.0 36.1 36.7 37.9 39.8 34.1 34.6 35.9 37.7 S/T 1.00 0.90 0.76 0.6 1.00 0.90 0.76 0.6 1.00 1.00 0.79 0.6 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.88 0.7 AT 31 29 26 22 31 29 26 22 31 29 26 22 31 29 26 22 30 29 25 22 32 30 26 23 1220 kW 2.39 2.39 2.38 2.4 2.64 2.64 2.63 2.7 2.92 2.92 2.91 2.9 3.22 3.22 3.21 3.2 3.56 3.56 3.55 3.6 3.95 3.95 3.95 4.0 Amps 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.3 10.5 10.5 10.5 10.6 11.9 11.9 11.9 12.0 13.5 13.4 13.4 13.5 15.3 15.3 15.2 15.3 Hi PR 238 239 241 245.1 276 277 278 282.5 315 316 317 321.6 357 358 360 363.7 402 403 405 409.1 451 452 453 457.6 Lo PR 121 123 126 130.7 128 130 133 137.9 135 136 139 144.3 140 142 145 149.6 145 147 150 154.9 152 153 156 161.5 MBh 42.2 42.7 43.9 45.8 41.8 42.4 43.6 45.4 40.7 41.3 42.5 44.4 38.9 39.5 40.7 42.5 36.7 37.2 38.5 40.3 34.6 35.2 36.4 38.3 S/T 1.00 0.96 0.82 0.7 1.00 0.97 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.95 0.8 AT 30 28 25 21 30 28 24 21 30 28 25 21 30 28 24 21 29 28 24 21 30 29 25 22 85 1400 kW 2.40 2.40 2.40 2.41 2.65 2.65 2.65 2.66 2.93 2.93 2.93 2.94 3.23 3.23 3.23 3.25 3.57 3.57 3.57 3.58 3.97 3.97 3.96 3.98 Amps 8.2 8.2 8.1 8.2 9.3 9.3 9.3 9.4 10.6 10.6 10.6 10.6 12.0 12.0 11.9 12.0 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 HIM 240 241 243 247.2 278 279 280 284.5 317 318 320 323.6 359 360 362 365.8 404 405 407 411.2 453 454 456 459.6 Lo PR 123 124 127 132.5 130 132 135 139.7 137 138 141 146.1 142 143 146 151.4 147 149 152 156.7 154 155 158 163.3 MBh 42.6 43.2 44.4 46.3 42.3 42.8 44.0 45.9 41.2 41.8 43.0 44.8 39.4 39.9 41.2 43.0 37.1 37.7 38.9 40.8 35.1 35.7 36.9 38.7 S/T 1.00 0.99 0.85 0.7 1.00 0.99 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.92 0.8 1.00 1.00 1.00 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 21 29 27 24 20 29 27 24 20 30 28 25 21 1530 kW 2.41 2.41 2.40 2.4 2.66 2.66 2.65 2.7 2.94 2.94 2.93 3.0 3.24 3.24 3.24 3.3 3.58 3.58 3.57 3.6 3.98 3.97 3.97 4.0 Amps 8.2 8.2 8.2 8.3 9.3 9.3 9.3 9.4 10.6 10.6 10.6 10.7 12.0 12.0 12.0 12.1 13.6 13.5 13.5 13.6 15.4 15.4 15.3 15.4 Hi PR 242 243 245 248.6 279 280 282 286.0 318 319 321 325.1 360 361 363 367.2 406 407 409 412.6 454 455 457 461.1 Lo PR 124 126 129 133.9 132 133 136 141.1 138 139 142 147.5 143 145 148 152.8 149 150 153 158.1 155 157 160 164.7 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n 0 0 0 sZ 3 a 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 46.7 47.3 48.7 - 46.2 46.9 48.3 - 45.0 45.7 47.1 - 43.0 43.6 45.0 - 40.4 41.1 42.4 - 38.1 38.7 40.1 --- S/T 0.63 0.56 0.42 0.64 0.56 0.43 0.66 0.59 0.45 0.68 0.61 0.47 1.00 0.63 0.49 1.00 0.68 0.54 --- AT 21 19 15 21 19 15 21 19 15 21 19 15 20 18 15 22 20 16 --- 1390 kW 2.68 2.68 2.68 2.98 2.97 2.97 3.31 3.30 3.30 3.66 3.66 3.65 4.06 4.05 4.05 4.52 4.52 4.52 --- Amps 9.3 9.3 9.3 10.7 10.7 10.6 12.2 12.2 12.2 13.8 13.8 13.8 15.6 15.6 15.6 17.8 17.7 17.7 --- Hi PR 241 242 244 279 280 282 319 320 322 362 363 36S 408 409 411 457 458 460 --- Lo PR 1 120 121 124 127 128 131 133 13S 138 138 140 143 144 145 148 150 152 155 --- MBh 46.9 47.5 48.9 46.4 47.1 48.5 45.2 45.9 47.3 43.2 43.8 45.2 40.6 41.3 42.7 38.3 39.0 40.3 --- S/T 0.65 0.57 0.44 0.65 0.58 0.45 0.68 0.60 0.47 0.70 0.62 0.49 1.00 0.64 0.51 1.00 0.69 0.56 --- AT 20 18 15 20 18 15 21 19 15 20 18 15 20 18 14 21 19 16 --- 70 1450 kW 2.69 2.69 2.68 2.98 2.98 2.97 3.31 3.31 3.30 3.67 3.66 3.66 4.06 4.06 4.05 4.53 4.53 4.52 --- Amps 9.4 9.3 9.3 10.7 10.7 10.7 12.2 12.2 12.2 13.8 13.8 13.8 15.6 15.6 15.6 17.8 17.8 17.7 --- Hi PR 242 243 245 280 281 283 320 321 322 362 364 365 409 410 411 458 459 460 --- Lo PR 120 122 125 127 129 132 134 135 138 139 141 144 144 146 149 151 152 155 --- M13h 47.4 48.0 49.4 46.9 47.6 49.0 45.7 46.4 47.8 43.7 44.3 45.7 41.1 41.8 43.2 38.8 39.5 40.8 --- S/T 0.67 0.60 0.47 0.68 0.61 0.47 0.70 0.63 0.50 0.72 0.65 0.52 1.00 0.67 0.54 1.00 0.72 0.59 --- AT 20 18 14 20 18 14 20 18 14 19 18 14 19 17 14 20 18 15 --- 1580 kW 2.70 2.69 2.69 2.99 2.99 2.98 3.32 3.32 3.31 3.67 3.67 3.67 4.07 4.07 4.06 4.54 4.53 4.53 --- Amps 9.4 9.4 9.4 10.7 10.7 10.7 12.2 12.2 12.2 13.9 13.9 13.8 15.7 15.7 15.7 17.8 17.8 17.8 --- HiPR 244 245 246 281 282 284 321 322 324 364 365 367 410 411 413 459 460 462 --- Lo PR 122 123 126 129 130 133 135 137 140 140 142 145 146 147 150 152 154 157 MBh 46.7 47.3 48.7 50.8 46.3 46.9 48.3 50.4 45.1 45.7 47.1 49.2 43.0 43.6 45.0 47.1 40.4 41.1 42.5 44.6 38.1 38.8 40.2 42.3 S/T 0.76 0.68 0.55 0.4 0.76 0.69 0.56 0.4 1.00 0.71 0.58 0.4 1.00 0.73 0.60 0.5 1.00 0.75 0.62 0.5 1.00 0.80 0.67 0.5 AT 25 23 19 16 25 23 19 15 25 23 20 16 25 23 19 15 25 23 19 15 26 24 20 16 1390 kW 2.68 2.68 2.67 2.7 2.98 2.97 2.97 3.0 3.30 3.30 3.30 3.3 3.66 3.66 3.65 3.7 4.06 4.05 4.05 4.1 4.52 4.52 4.51 4.5 Amps 9.3 9.3 9.3 9.4 10.7 10.7 10.6 10.7 12.2 12.2 12.1 12.2 13.8 13.8 13.8 13.9 15.6 15.6 15.6 15.7 17.7 17.7 17.7 17.8 Hi PR 242 243 244 248.6 280 281 282 286.5 319 320 322 326.2 362 363 365 368.9 408 409 411 415.0 457 458 460 464.2 Lo PR 120 121 124 129.2 127 128 131 136.4 133 135 138 142.7 139 140 143 148.0 144 145 148 153.3 150 152 155 159.9 MBh 46.9 47.5 48.9 51.0 46.5 47.1 48.5 50.6 45.3 45.9 47.3 49.4 43.2 43.8 45.2 47.3 40.6 41.3 42.7 44.8 38.3 39.0 40.4 42.5 S/T 0.77 0.70 0.57 0.4 0.78 0.70 0.57 0.4 1.00 0.73 0.60 0.5 1.00 0.75 0.62 0.5 1.00 0.77 0.64 0.5 1.00 0.82 0.69 0.5 AT 25 23 19 15 25 23 19 15 25 23 19 15 25 23 19 15 24 22 19 15 26 24 20 16 75 1450 kW 2.69 2.68 2.68 2.70 2.98 2.98 2.97 2.99 3.31 3.31 3.30 3.32 3.66 3.66 3.66 3.68 4.06 4.06 4.05 4.08 4.53 4.52 4.52 4.54 Amps 9.3 9.3 9.3 9.4 10.7 10.7 10.7 10.8 12.2 12.2 12.2 12.3 13.8 13.8 13.8 13.9 15.6 15.6 15.6 15.7 17.8 17.8 17.7 17.8 Hi PR 242 243 245 249.2 280 281 283 287.1 320 321 323 326.8 363 364 365 369.6 409 410 412 415.7 458 459 461 464.9 Lo PR 120 122 125 129.8 127 129 132 137.0 134 135 138 143.3 139 141 144 148.6 144 146 149 153.9 151 152 155 160.4 MBh 47.4 48.0 49.4 51.5 47.0 47.6 49.0 51.1 45.8 46.4 47.8 49.9 43.7 44.3 45.7 47.8 41.1 41.8 43.2 45.3 38.8 39.5 40.9 43.0 S/T 0.80 0.73 0.59 O.S 0.81 0.73 0.60 0.5 1.00 0.76 0.62 0.5 1.00 0.77 0.64 0.5 1.00 0.80 0.66 0.5 1.00 0.85 0.71 0.6 AT 24 22 18 14 24 22 18 14 24 22 18 15 24 22 18 14 24 22 18 14 25 23 19 15 1580 kW 2.70 2.69 2.69 2.7 2.99 2.99 2.98 3.0 3.32 3.32 3.31 3.3 3.67 3.67 3.67 3.7 4.07 4.07 4.06 4.1 4.54 4.53 4.53 4.6 Amps 9.4 9.4 9.4 9.5 10.7 10.7 10.7 10.8 12.2 12.2 12.2 12.3 13.9 13.9 13.8 13.9 15.7 15.7 15.6 15.8 17.8 17.8 17.8 17.9 Hi PR 244 245 246 250.7 282 283 284 288.6 321 322 324 328.3 364 365 367 371.0 410 411 413 417.1 459 460 462 466.3 Lo PR 122 123 126 131.1 129 130 133 138.3 135 137 140 144.6 140 142 145 150.0 146 147 150 155.2 152 154 157 161.8 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n 0 0 0 sz v 3 dip n 0 3 OUTDOOR AMBIENT TEMPERATURE 659F 752F 852E F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 46.9 47.6 49.0 51.1 46.5 47.2 48.5 50.7 45.3 46.0 47.3 49.4 43.2 43.9 45.3 47.4 40.7 41.3 42.7 44.8 38.4 39.0 40.4 42.5 S/T 0.88 0.80 0.67 0.5 1.00 0.81 0.68 0.5 1.00 0.83 0.70 0.6 1.00 0.85 0.72 0.6 1.00 1.00 0.74 0.6 1.00 1.00 0.79 0.7 AT 29 27 24 20 29 27 24 20 30 28 24 20 29 27 24 20 29 27 23 20 30 28 25 21 1390 kW 2.68 2.68 2.68 2.7 2.98 2.97 2.97 3.0 3.30 3.30 3.30 3.3 3.66 3.66 3.65 3.7 4.06 4.05 4.05 4.1 4.52 4.52 4.52 4.5 Amps 9.3 9.3 9.3 9.4 10.7 10.7 10.6 10.7 12.2 12.2 12.1 12.3 13.8 13.8 13.8 13.9 15.6 15.6 15.6 15.7 17.8 17.7 17.7 17.8 Hi PR 242 243 245 249.0 280 281 283 286.9 320 321 322 326.6 362 364 365 369.4 409 410 411 415.5 458 459 460 464.7 Lo PR 120 122 125 129.7 127 129 132 136.9 134 135 138 143.2 139 141 144 148.6 144 146 149 153.8 151 152 155 160.4 MBh 47.1 47.8 49.2 51.3 46.7 47.4 48.8 50.9 45.5 46.2 47.5 49.7 43.4 44.1 45.5 47.6 40.9 41.5 42.9 45.0 38.6 39.2 40.6 42.7 S/T 0.89 0.82 0.69 0.5 1.00 0.83 0.69 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.81 0.7 AT 29 27 23 20 29 27 23 19 29 27 24 20 29 27 23 19 29 27 23 19 30 28 24 20 80 1450 kW 2.69 2.68 2.68 2.70 2.98 2.98 2.97 3.00 3.31 3.31 3.30 3.32 3.66 3.66 3.66 3.68 4.06 4.06 4.05 4.08 4.53 4.52 4.52 4.54 Amps 9.4 9.3 9.3 9.4 10.7 10.7 10.7 10.8 12.2 12.2 12.2 12.3 13.8 13.8 13.8 13.9 15.6 15.6 15.6 15.7 17.8 17.8 17.7 17.8 Hi PR 243 244 245 249.7 281 282 283 287.6 320 321 323 327.3 363 364 366 370.0 409 410 412 416.1 458 459 461 465.3 Lo PR 121 122 125 130.3 128 129 132 137.5 134 136 139 143.8 140 141 144 149.2 145 146 149 154.4 151 153 156 161.0 MBh 47.6 48.3 49.7 51.8 47.2 47.9 49.3 51.4 46.0 46.7 48.0 50.2 43.9 44.6 46.0 48.1 41.4 42.0 43.4 45.5 39.1 39.7 41.1 43.2 S/T 0.92 0.85 0.72 0.6 1.00 0.85 0.72 0.6 1.00 0.88 0.75 0.6 1.00 0.90 0.76 0.6 1.00 1.00 0.79 0.6 1.00 1.00 0.84 0.7 AT 28 26 23 19 28 26 23 19 29 27 23 19 28 26 23 19 28 26 22 18 29 27 24 20 1580 kW 2.70 2.69 2.69 2.7 2.99 2.99 2.98 3.0 3.32 3.32 3.31 3.3 3.67 3.67 3.67 3.7 4.07 4.07 4.06 4.1 4.54 4.53 4.53 4.6 Amps 9.4 9.4 9.4 9.5 10.7 10.7 10.7 10.8 12.2 12.2 12.2 12.3 13.9 13.9 13.8 13.9 15.7 15.7 15.7 15.8 17.8 17.8 17.8 17.9 Hi PR 244 245 247 251.1 282 283 285 289.0 322 323 325 328.7 365 366 367 371.5 411 412 413 417.5 460 461 463 466.7 Lo PR 122 124 127 131.6 129 131 134 138.8 136 137 140 145.2 141 142 145 150.5 146 148 151 155.7 153 154 157 162.3 MBh 47.7 48.4 49.7 51.8 47.3 47.9 49.3 51.4 46.1 46.7 48.1 50.2 44.0 44.7 46.0 48.1 41.5 42.1 43.5 45.6 39.1 39.8 41.2 43.3 S/T 1.00 0.90 0.77 0.6 1.00 0.91 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.89 0.8 AT 33 31 28 24 33 31 28 24 34 32 28 24 33 31 28 24 33 31 27 23 34 32 29 25 1390 kW 2.69 2.69 2.68 2.7 2.98 2.98 2.97 3.0 3.31 3.31 3.30 3.3 3.67 3.66 3.66 3.7 4.06 4.06 4.06 4.1 4.53 4.53 4.52 4.5 Amps 9.4 9.3 9.3 9.4 10.7 10.7 10.7 10.8 12.2 12.2 12.2 12.3 13.8 13.8 13.8 13.9 15.7 15.6 15.6 15.7 17.8 17.8 17.7 17.9 Hi PR 243 244 246 250.2 281 282 284 288.1 321 322 324 327.8 364 365 366 370.5 410 411 412 416.6 459 460 462 465.8 Lo PR 122 123 126 131.5 129 131 134 138.7 135 137 140 145.0 141 142 145 150.3 146 148 151 155.6 153 154 157 162.2 MBh 47.9 48.6 49.9 52.1 47.5 48.1 49.5 51.6 46.3 46.9 48.3 50.4 44.2 44.9 46.2 48.4 41.7 42.3 43.7 45.8 39.3 40.0 41.4 43.5 S/T 1.00 0.92 0.79 0.6 1.00 0.93 0.79 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.91 0.8 AT 33 31 27 23 33 31 27 23 33 31 27 24 33 31 27 23 33 31 27 23 34 32 28 24 85 1450 kW 2.69 2.69 2.69 2.71 2.99 2.98 2.98 3.00 3.32 3.31 3.31 3.33 3.67 3.67 3.66 3.69 4.07 4.06 4.06 4.08 4.53 4.53 4.53 4.55 Amps 9.4 9.4 9.3 9.5 10.7 10.7 10.7 10.8 12.2 12.2 12.2 12.3 13.9 13.8 13.8 13.9 15.7 15.7 15.6 15.7 17.8 17.8 17.8 17.9 Hi PR 244 245 247 250.8 282 283 285 288.7 322 323 324 328.4 364 365 367 371.2 410 411 413 417.3 460 461 462 466.5 Lo PR 123 124 127 132.1 130 131 134 139.3 136 138 141 145.6 141 143 146 150.9 147 148 151 156.2 153 155 158 162.7 MBh 48.4 49.1 50.4 52.6 48.0 48.7 50.0 52.1 46.8 47.4 48.8 50.9 44.7 45.4 46.7 48.9 42.2 42.8 44.2 46.3 39.8 40.5 41.9 44.0 S/T 1.00 0.95 0.81 0.7 1.00 0.95 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 1.00 0.8 AT 32 30 27 23 32 30 26 23 32 30 27 23 32 30 26 23 32 30 26 22 33 31 27 24 1580 kW 2.70 2.70 2.69 2.7 3.00 2.99 2.99 3.0 3.32 3.32 3.32 3.3 3.68 3.68 3.67 3.7 4.08 4.07 4.07 4.1 4.54 4.54 4.53 4.6 Amps 9.4 9.4 9.4 9.5 10.8 10.8 10.7 10.8 12.3 12.3 12.2 12.3 13.9 13.9 13.9 14.0 15.7 15.7 15.7 15.8 17.8 17.8 17.8 17.9 Hi PR 245 246 248 252.2 283 284 286 290.1 323 324 326 329.8 366 367 368 372.6 412 413 414 418.7 461 462 464 467.9 Lo PR 124 125 128 133.4 131 133 136 140.6 137 139 142 146.9 143 144 147 152.3 148 149 152 157.5 155 156 159 164.1 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k 0 0 0 sz 3 a 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 56.7 57.5 59.2 - 56.2 57.0 58.7 - 54.7 55.5 57.2 - 52.2 53.0 54.7 - 49.1 49.9 51.6 - 46.3 47.1 48.8 - S/T 0.61 0.54 0.41 0.61 0.54 0.42 0.63 0.56 0.44 0.65 0.58 0.46 0.67 0.60 0.48 0.72 0.65 0.53 AT 22 20 16 22 20 16 23 20 16 22 20 16 22 20 16 23 21 17 1460 kW 3.37 3.37 3.36 3.76 3.76 3.75 4.20 4.20 4.19 4.68 4.67 4.67 5.21 5.20 5.20 5.83 5.82 5.82 Amps 12.5 12.5 12.4 14.3 14.3 14.2 16.3 16.3 16.2 18.5 18.4 18.4 20.9 20.9 20.8 23.7 23.7 23.7 HiPR 247 249 250 286 287 289 327 328 330 370 371 373 417 419 420 468 469 471 Lo PR 111 112 115 117 119 121 123 124 127 128 129 132 133 134 137 139 140 143 MBh 57.9 58.7 60.3 57.4 58.2 59.8 55.9 56.7 58.4 53.4 54.2 55.9 50.3 51.1 52.8 47.5 48.3 50.0 S/T 0.64 0.57 0.45 0.65 0.58 0.45 0.67 0.60 0.48 0.69 0.62 0.50 0.71 0.64 0.52 0.75 0.69 0.56 AT 21 19 15 21 19 15 21 19 15 21 19 15 20 18 14 22 20 16 70 1700 kW 3.39 3.39 3.38 3.79 3.78 3.78 4.22 4.22 4.21 4.70 4.69 4.69 5.23 5.23 5.22 5.85 5.85 5.84 Amps 12.6 12.6 12.5 14.4 14.4 14.3 16.4 16.4 16.3 18.6 18.5 18.5 21.0 21.0 20.9 23.8 23.8 23.8 HiPR 250 251 253 289 290 292 329 330 332 373 374 376 420 421 423 470 471 473 Lo PR 113 114 117 120 121 124 125 127 130 130 132 134 135 137 139 141 143 145 MBh 59.3 60.1 61.8 58.8 59.6 61.3 57.4 58.2 59.8 54.9 55.7 57.3 51.8 52.6 54.2 49.0 49.8 51.4 S/T 0.64 0.57 0.45 0.65 0.58 0.46 0.67 0.60 0.48 0.69 0.62 0.50 0.71 0.64 0.52 1.00 0.69 0.56 AT 20 17 13 20 17 13 20 18 14 20 17 13 19 17 13 21 18 14 1930 kW 3.41 3.41 3.40 3.80 3.80 3.79 4.24 4.24 4.23 4.72 4.71 4.71 5.25 5.24 5.24 5.87 5.87 5.86 Amps 12.7 12.6 12.6 14.5 14.4 14.4 16.5 16.5 16.4 18.6 18.6 18.6 21.1 21.1 21.0 23.9 23.9 23.9 HiPR 253 254 256 292 293 294 332 333 335 376 377 379 423 424 426 473 474 476 Lo PR 116 117 120 122 124 126 128 130 132 133 134 137 138 139 142 144 145 148 MBh 56.7 57.5 59.2 61.7 56.2 57.0 58.7 61.2 54.8 55.6 57.2 59.8 52.2 53.0 54.7 57.3 49.2 50.0 51.6 54.2 46.4 47.2 48.8 51.4 S/T 0.72 0.65 0.53 0.4 0.73 0.66 0.54 0.4 0.75 0.68 0.56 0.4 0.77 0.70 0.58 0.4 0.79 0.72 0.60 0.5 1.00 0.77 0.64 0.5 AT 27 25 21 17 27 25 21 17 27 25 21 17 27 25 21 17 27 25 20 16 28 26 22 18 1460 kW 3.37 3.36 3.36 3.4 3.76 3.76 3.75 3.8 4.20 4.20 4.19 4.2 4.67 4.67 4.66 4.7 5.20 5.20 5.19 5.2 5.83 5.82 5.82 5.8 Amps 12.5 12.5 12.4 12.6 14.3 14.3 14.2 14.4 16.3 16.3 16.2 16.4 18.4 18.4 18.4 18.5 20.9 20.9 20.8 21.0 23.7 23.7 23.7 23.8 HiPR 248 249 250 254.7 286 287 289 293.4 327 328 330 334.0 371 372 373 377.7 418 419 420 424.8 468 469 471 475.0 Lo PR 111 112 115 119.4 117 119 121 126.0 123 124 127 131.9 128 129 132 136.8 133 134 137 141.6 139 140 143 147.6 MBh 57.9 58.7 60.4 62.9 57.4 58.2 59.9 62.4 56.0 56.7 58.4 61.0 53.4 54.2 55.9 58.5 50.4 51.2 52.8 55.4 47.6 48.4 50.0 52.6 S/T 0.76 0.69 0.57 0.4 0.76 0.70 0.S7 0.4 0.79 0.72 0.59 0.5 0.80 0.74 0.61 0.S 1.00 0.76 0.63 0.5 1.00 0.80 0.68 0.5 AT 26 23 19 15 26 23 19 15 26 24 20 15 26 23 19 15 25 23 19 15 27 24 20 16 75 1700 kW 3.39 3.39 3.38 3.41 3.78 3.78 3.77 3.80 4.22 4.22 4.21 4.24 4.70 4.69 4.69 4.72 5.23 5.22 5.22 5.25 5.85 5.84 5.84 5.87 Amps 12.6 12.6 12.5 12.7 14.4 14.4 14.3 14.5 16.4 16.4 16.3 16.5 18.5 18.5 18.5 18.6 21.0 21.0 20.9 21.1 23.8 23.8 23.8 23.9 Hi PR 250 251 253 257.4 289 290 292 296.1 330 331 332 336.7 373 374 376 380.3 420 421 423 427.4 471 472 473 477.7 Lo PR 113 114 117 121.8 120 121 124 128.4 125 127 130 134.2 130 132 135 139.2 135 137 139 144.0 141 143 145 150.0 MBh 59.4 60.2 61.8 64.4 58.9 59.7 61.3 63.9 57.4 58.2 59.9 62.4 54.9 55.7 57.4 59.9 51.8 52.6 54.3 56.8 49.0 49.8 51.5 54.0 S/T 0.76 0.69 0.57 0.4 0.77 0.70 0.57 0.4 0.79 0.72 0.60 0.5 0.81 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 0.80 0.68 0.6 AT 24 22 18 14 24 22 18 14 25 23 18 14 24 22 18 14 24 22 18 14 25 23 19 15 1930 kW 3.41 3.41 3.40 3.4 3.80 3.80 3.79 3.8 4.24 4.24 4.23 4.3 4.71 4.71 4.70 4.7 5.24 5.24 5.23 5.3 5.87 5.86 5.86 5.9 Amps 12.7 12.6 12.6 12.7 14.4 14.4 14.4 14.5 16.5 16.4 16.4 16.5 18.6 18.6 18.6 18.7 21.1 21.0 21.0 21.1 23.9 23.9 23.9 24.0 Hi PR 253 254 256 260.1 292 293 295 298.8 332 333 335 339.3 376 377 379 383.0 423 424 426 430.1 473 474 476 480.4 Lo PR 116 117 120 124.5 122 124 127 131.1 128 130 132 137.0 133 134 137 141.9 138 139 142 146.7 144 145 148 152.7 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n z ri m 0 n O O 'z G) 0 0 0 sZ v 3 dip n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 57.0 57.8 59.5 62.0 56.5 57.3 59.0 61.5 55.1 55.8 57.5 60.1 52.5 53.3 55.0 57.6 49.5 50.3 51.9 54.5 46.7 47.5 49.1 51.7 S/T 0.84 0.77 0.64 0.5 0.84 0.77 0.65 0.5 1.00 0.80 0.67 0.5 1.00 0.81 0.69 0.6 1.00 0.83 0.71 0.6 1.00 0.88 0.76 0.6 AT 32 30 26 21 32 30 26 21 32 30 26 22 32 30 26 21 32 29 25 21 33 31 27 22 1460 kW 3.37 3.37 3.36 3.4 3.76 3.76 3.75 3.8 4.20 4.20 4.19 4.2 4.68 4.67 4.67 4.7 5.21 5.20 5.20 5.2 5.83 5.82 5.82 5.8 Amps 12.5 12.5 12.4 12.6 14.3 14.3 14.2 14.4 16.3 16.3 16.2 16.4 18.5 18.4 18.4 18.5 20.9 20.9 20.8 21.0 23.7 23.7 23.7 23.8 HIM 248 249 251 255.2 287 288 290 293.9 327 328 330 334.5 371 372 374 378.1 418 419 421 425.2 468 469 471 475.5 Lo PR 111 112 115 119.9 118 119 122 126.5 124 125 128 132.3 128 130 133 137.3 133 135 137 142.1 139 141 143 148.1 MBh 58.2 59.0 60.7 63.2 57.7 58.5 60.2 62.7 56.2 57.0 58.7 61.3 53.7 54.5 56.2 58.7 50.7 51.5 53.1 55.7 47.9 48.6 50.3 52.9 S/T 0.87 0.80 0.68 0.6 0.88 0.81 0.69 0.6 1.00 0.83 0.71 0.6 1.00 0.85 0.73 0.6 1.00 0.87 0.75 0.6 1.00 0.92 0.79 0.7 AT 30 28 24 20 30 28 24 20 31 29 24 20 30 28 24 20 30 28 24 20 31 29 25 21 80 1700 kW 3.39 3.39 3.38 3.41 3.78 3.78 3.77 3.80 4.22 4.22 4.21 4.24 4.70 4.69 4.69 4.72 5.23 5.22 5.22 5.25 5.85 5.85 5.84 5.87 Amps 12.6 12.6 12.5 12.7 14.4 14.4 14.3 14.5 16.4 16.4 16.3 16.5 18.6 18.5 18.5 18.6 21.0 21.0 20.9 21.1 23.8 23.8 23.8 23.9 Hi PR 251 252 254 257.8 289 291 292 296.6 330 331 333 337.1 374 375 377 380.8 421 422 424 427.9 471 472 474 478.1 Lo PR 114 115 118 122.3 120 121 124 128.9 126 127 130 134.7 131 132 135 139.6 136 137 140 144.5 142 143 146 150.5 MBh 59.7 60.4 62.1 64.7 59.2 59.9 61.6 64.2 57.7 58.5 60.2 62.7 55.2 56.0 57.6 60.2 52.1 52.9 54.6 57.1 49.3 50.1 51.8 54.3 S/T 0.87 0.81 0.68 0.6 1.00 0.81 0.69 0.6 1.00 0.83 0.71 0.6 1.00 0.85 0.73 0.6 1.00 0.87 0.75 0.6 1.00 1.00 0.80 0.7 AT 29 27 23 19 29 27 23 19 30 27 23 19 29 27 23 19 29 27 23 18 30 28 24 20 1930 kW 3.41 3.41 3.40 3.4 3.80 3.80 3.79 3.8 4.24 4.24 4.23 4.3 4.72 4.71 4.71 4.7 5.25 5.24 5.24 5.3 5.87 5.86 5.86 5.9 Amps 12.7 12.6 12.6 12.8 14.5 14.4 14.4 14.6 16.5 16.5 16.4 16.6 18.6 18.6 18.6 18.7 21.1 21.0 21.0 21.2 23.9 23.9 23.9 24.0 Hi PR 253 255 256 260.5 292 293 295 299.2 333 334 336 339.8 376 377 379 383.5 423 425 426 430.6 474 475 477 480.8 Lo PR 116 118 120 125.0 123 124 127 131.6 129 130 133 137.4 134 135 138 142.3 138 140 143 147.2 144 146 149 153.2 MBh 58.0 58.7 60.4 63.0 57.5 58.2 59.9 62.5 56.0 56.8 58.5 61.0 53.5 54.3 55.9 58.5 50.4 51.2 52.9 55.4 47.6 48.4 50.1 52.6 S/T 1.00 0.86 0.74 0.6 1.00 0.87 0.74 0.6 1.00 0.89 0.76 0.6 1.00 0.91 0.78 0.7 1.00 1.00 0.80 0.7 1.00 1.00 0.85 0.7 AT 36 34 30 26 36 34 30 26 36 34 30 26 36 34 30 26 36 34 30 25 37 35 31 27 1460 kW 3.38 3.37 3.37 3.4 3.77 3.77 3.76 3.8 4.21 4.21 4.20 4.2 4.68 4.68 4.67 4.7 5.21 5.21 5.20 5.2 5.84 5.83 5.83 5.9 Amps 12.5 12.5 12.5 12.6 14.3 14.3 14.3 14.4 16.3 16.3 16.3 16.4 18.5 18.5 18.4 18.6 20.9 20.9 20.9 21.0 23.8 23.7 23.7 23.9 Hi PR 249 250 252 256.3 288 289 291 295.0 329 330 331 335.6 372 373 375 379.3 419 420 422 426.4 470 471 472 476.6 Lo PR 113 114 117 121.5 119 121 124 128.2 125 127 129 134.0 130 131 134 138.9 135 136 139 143.7 141 142 145 149.7 MBh 59.2 59.9 61.6 64.2 58.7 59.4 61.1 63.7 57.2 58.0 59.7 62.2 54.7 55.5 57.1 59.7 51.6 52.4 54.1 56.6 48.8 49.6 51.3 53.8 S/T 1.00 0.90 0.77 0.6 1.00 0.90 0.78 0.6 1.00 0.92 0.80 0.7 1.00 0.94 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.89 0.8 AT 35 33 29 24 35 33 28 24 35 33 29 25 35 32 28 24 34 32 28 24 36 34 29 25 85 1700 kW 3.40 3.40 3.39 3.42 3.79 3.79 3.78 3.81 4.23 4.23 4.22 4.25 4.71 4.70 4.70 4.73 5.24 5.23 5.23 5.26 5.86 5.85 5.85 5.88 Amps 12.6 12.6 12.6 12.7 14.4 14.4 14.4 14.5 16.4 16.4 16.4 16.5 18.6 18.6 18.5 18.7 21.0 21.0 21.0 21.1 23.9 23.8 23.8 24.0 Hi PR 252 253 255 259.0 291 292 293 297.7 331 332 334 338.3 375 376 378 381.9 422 423 425 429.0 472 473 475 479.3 Lo PR 115 116 119 123.9 122 123 126 130.5 128 129 132 136.4 133 134 137 141.3 137 139 141 146.1 143 145 147 152.1 MBh 60.6 61.4 63.1 65.6 60.1 60.9 62.6 65.1 58.6 59.4 61.1 63.7 56.1 56.9 58.6 61.1 53.1 53.8 55.5 58.1 50.2 51.0 52.7 55.3 S/T 1.00 0.90 0.77 0.6 1.00 0.90 0.78 0.7 1.00 0.93 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.89 0.8 AT 34 31 27 23 34 31 27 23 34 32 28 23 33 31 27 23 33 31 27 23 35 32 28 24 1930 kW 3.42 3.41 3.41 3.4 3.81 3.81 3.80 3.8 4.25 4.25 4.24 4.3 4.72 4.72 4.71 4.7 5.25 5.25 5.24 5.3 5.88 5.87 5.87 5.9 Amps 12.7 12.7 12.7 12.8 14.5 14.5 14.4 14.6 16.5 16.5 16.5 16.6 18.7 18.7 18.6 18.8 21.1 21.1 21.1 21.2 23.9 23.9 23.9 24.0 Hi PR 255 256 257 261.7 293 294 296 300.4 334 335 337 341.0 378 379 380 384.6 425 426 427 431.7 475 476 478 482.0 Lo PR 118 119 122 126.6 124 126 129 133.3 130 132 134 139.1 135 137 139 144.0 140 141 144 148.8 146 147 150 154.8 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n PERFORMANCE DATA GSXH501810**/CA*TA1818*4A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 600 CFM 75 18,850 13,250 5,600 1,190 80 18,650 13,350 5,300 1,260 85 18,400 13,400 5,000 1,320 90 18,000 13,300 4,700 1,390 95 •I 13,150 4,450 1,450 100 17,150 12,950 4,200 11530 105 16,650 12,750 3,900 1,610 110 16,200 12,800 3,400 1,700 115 15,750 12,850 2,900 1,790 TVA CONDITIONS @ 95' OD DB, 75° ID DB 63° ID WB 95' 17,000 12,850 4,150 1,460 GSXH503010**/CA*TA3022*4A* CONDITIONS: 80 °F IBD, 671 IWB @ 1000 CFM 75 30,450 21,200 9,250 1,870 80 30,100 21,300 8,800 1,970 85 29,700 21,400 8,300 2,070 90 29,050 21,200 7,850 2,180 95 411 21,000 7,400 2,280 100 27,600 20,750 6,850 21400 105 26,800 20,450 6,350 2,510 110 26,100 20,550 5,550 2,650 115 25,350 20,600 4,750 2,790 TVA CONDITIONS @ 95` OD DB, 75° ID DB 63° ID WB 95° 27,400 20,550 6,850 2,280 GSXH504210**/CA*TA4230*4A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1400 CFM 75 42,900 31,100 11,800 2,640 80 42,400 31,250 11,150 2,780 85 41,850 31,400 10,450 2,920 90 40,950 31,100 9,850 3,070 95 •00 30,800 9,200 3,220 100 38,900 30,400 8,500 3,390 105 37,750 29,950 7,800 3,560 110 36,750 30,100 6,650 3,760 115 35,750 30,200 5,550 3,960 TVA CONDITIONS @ 95' OD DB, 75° ID DB 63° ID WB 95° 38,550 30,100 8,450 3,230 GSXH506010**/CA*T4961*4A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1700 CFM 75 60,150 41,250 18,900 3,770 80 59,450 41,450 18,000 3,990 85 58,700 41,600 17,100 4,210 90 57,450 41,200 16,250 4,450 95 56,200 40,800 15,400 4,690 100 54,650 40,250 14,400 105 53,100 39,650 13,450[4,960 5,220 110 51,700 39,800 11,9005,530 115 50,300 39,900 10,4005,840 TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95° 54,250 39,900 14,350 4,690 GSXH502410**/CA*TA2422*4A* CONDITIONS: 80 °F IBD, 671 IWB @ 795 CFM 75 25,300 17,150 8,150 1,580 80 25,000 17,250 7,750 1,670 85 24,700 17,300 7,400 1,750 90 24,150 17,150 7,000 1,840 95 .11 17,000 6,600 1,930 100 22,950 16,750 6,200 21030 105 22,300 16,500 5,800 2,130 110 21,700 16,600 5,100 2,250 115 21,100 16,650 4,450 2,370 TVA CONDITIONS @ 95° OD DB, 75° ID DB 63° ID WB 95, 22,750 16,600 6,150 1,930 GSXH503610**/CA*TA3626*4A* CONDITIONS: 801 IBD, 67 °F IWB @ 1145 CFM OUTDOOR 75 TOTAL 36,650 SENSIBLE 25,900 LATENT 10,750 TOTAL 2,280 80 36,200 26,050 10,150 2,410 85 35,750 26,150 9,600 2,530 90 35,000 25,900 9,100 2,660 95 00 25,650 8,550 2,790 100 33,250 25,300 7,950 2,940 105 32,300 24,950 7,350 3,090 110 31,450 25,050 6,400 3,270 115 30,550 25,150 5,400 3,450 TVA CONDITIONS @ 95" OD DB, 75' ID DB 63' ID WB 95° 33,000 25,050 7,950 2,800 GSXH504810**/CA*T4961*4A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1450 CFM 75 48,750 33,850 14,900 2,970 80 48,150 34,000 14,150 3,140 85 47,550 34,150 13,400 3,300 90 46,500 33,850 12,650 3,480 •0 3,660 100 44,200 33,100 11,100 3,860 105 42,900 32,600 10,300 4,050 110 41,750 32,750 9,000 4,290 115 40,600 32,850 7,750 4,520 TVA CONDITIONS @ 95" OD DB, 75° ID DB 63° ID WB 95° 43,850 32,800 11,050 3,660 18 www.goodmanmfg.com SS-GSXH5 DIMENSIONS MODEL DIMENSIONS W. D„ H" GSXH501810A* 26 26 27 GSXH502410A* 29 29 32 GSXH503010A* 35Y2 35X 39X GSXH503610A* 35Y2 35X 39X GSXH504210A* 35X 35%: 36% GSXH504810A* 35% 35% 36X GSXH506010A* 35Y2 35%Z 41% El��% _�!.�..... � ��" ll� I .... IA�lUlll� �J SS-GSXH5 www.goodmanmfg.com 19 N O 0 O O Cl 3 3 0 O 3 Ln LP G) N x Ln CONTROLBOX Q T10TT T2TT0 LiQ L2Q ALTERNATE DOUBLE POLE CONTACTOR MAIN PU AUX BR 10 BK CM Sc BL BK BK BK RD RD BL T1 T2 RD I RD ,BK L1 L2a I 1 BK K DT I I COMP MAIN RD BK AUX YL C B R D WYL � EWBK RCCF —YLI i SA (IF USED) NOTE �•RD 0 EQUIPMENT GROUND SEE NOTE _Y SEE NOTE 1 —C SEE NOTE 3 LVJB COLOR CODE BK---- BLACK BL------------- BLUE BR -------- BROWN OR -------------- ORANGE PU-------- PURPLE RD-------------- RED WH----------- WHITE YL --- YELLOW WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE COMPONENTCODE C-------------- CONTACTOR CH----- CRANKCASE HEATER CHS-- CRANKCASE HEATER SWITCH CM --OUTDOOR FAN MOTOR COMP — COMPRESSOR DT --- --- DISCHARGE THERMOSTAT 10 --- INTERNAL OVERLOAD LVJB ----- LOW VOLTAGE JUNCTION BOX RCCF RUN CAPACITOR FOR COMPRESSOR & FAN SA -------- START ASSIST SC -- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR - START RELAY FOR COMPRESSOR (OPTIONAL) CONTROLS SHOWN WITH THERMOSTAT IN'OFF' POSITION. IOUTDOOR POWER SUPPLY I SEE RATING PLATE SEE NOTE 3 LI 5 SR 2 1 SC T2 C 10 H C C PJ� S w Z RCCF ' 10 COMP 1 1 I o a R I F U I QF I Iz z w Q O 10 P (IF USED) BK M BK M 9iti J CH �YNIw— — LN DT C Y C SEE NOTE 3 SEE NOTE 1 NOTES: • • T 1. 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR THERMOSTAT.USE N.E.C. CLASS 2 WIRE. 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTORS ONLY. 4) CH AND CHS USED ON 3.5T AND 4T ONLY. 0140R00794-B Wiring is subject to change. Always referto the wiring I High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L diagram or the unit for the most up-to-date wiring. WARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. 7 (N N X 2 Ul BL CONTROLBOX BL Q T1TO T2TO (Ja�J L1/p L2Jp� ALTERNATE DOUBLE POLE CONTACTOR GRF-1 RI I J BK _BK I YLI LVJB YL —Y2 PU—Y1 SEE NOTE BIL SEE NOTE PU DT BK J I COLOR CODE BK------------- BLACK BL--------------- BLUE SR------------- BROWN BL OR --------------- ORANGE SC PU------------. PURPLE RD--------------- RED W H---------- WHITE BK BR YL---------------- YELLOW GR/YL---------- GREEWYELLOW STRIPE BK BK RD RD BL GR---------------GREEN T1 T2 R J I WIRING CODE RD FACTORYWIRING BK L1 L2 1 HIGH VOLTAGE LOW VOLTAGE C OPTIONAL HIGH VOLTAGE 1 1 � FIELD WIRING PY�LL HIGH VOLTAGE COMPONENTCODE I ' RCCC-----------CONTRACTOR CM ------------ OUTDOOR FAN MOTOR COMP-------- COMPRESSOR 10----------- INTERNAL OVERLOAD YLLVJB-------- LOWVOLTAGE JUNCTION BOX YL RCC----------- RUN CAPACITOR FOR COMPRESSOR j I SA------------- START ASSIST ' 1 SC---------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) I SR---------- START RELAY FOR COMPRESSOR (OPTIONAL) BL CH ------------- CRANKCASE HEATER IR SA JCHS------------ CRANKCASE HEATER SWITCH BK (IF"EP) RD DT------------ DISCHARGE THERMOSTAT CS-------------- COMPRESSOR SOLENOID — O CONTROLS SHOWN WITH THERMOSTAT IN'OFP POSITION. IOUTDOOR POWER SUPPLY I SEE RATING PLATE I SEE NOTE 3 I T1 T2 L1 5 SR z 1 Sc C A 'C v 10 H C D °+ 1 P RCCF Iw z I m 0 COMP 1 ; o 0 R 1 F F o w� G 0 CM (IF USED) BK GR/YL L1 L2 RD r CH �RK RD�Oi�RD GR SEE NOTE 4 JBL SEE NOTE 1SEE NOTE 3 NOTES: COMP MAIN RJcls 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & KEQUIPMENT GROUND INDOOR THERMOSTAT. USE N.E.C. CLASS 2 WIRE. AUX SEE NOTE 3 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. cs 3) USE COPPER CONDUCTORS ONLY. 4) CRANKCASE HEATER & CRANKCASE HEATER SWITCH CH ARE FA7CTORY INSTALLED OPTIONAL. �y OR S J . R 0140ROO795-B Wiring is subject to change. Always refer to the wiring I High Voltage: Disconnect all power before servicing or installing this unit. Multiple power diagram or the unit for the most up-to-date wiring. A WARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. 7 0 G> 0 I- O 9F ACCESSORIES .. - -: Q ,, ABK-20 Anchor Bracket Kit A X X X X X X X ABK-21 Anchor Bracket Kit A ASC-01 Anti -Short Cycle Kit X X X X X X X CSR-U-1 Hard -start Kit X X X X CSR-U-2 Hard -start Kit X X X X CSR-U-3 Hard -start Kit X X FSK01A' Freeze Protection Kit X X X X X X X LSK02A Liquid Line Solenoid Kit X X X X X X X LAKT01 Low -Ambient Kit X X X X X X 0130ROOOOOS Low -Pressure Switch Kit X X X X X X X TXV-FX-KX-2T z TXV Kit X X TXV-FX-KX-3T z TXV Kit X X TXV-FX-KX-ST: TXV Kit X X X Contains 20 brackets; four brackets needed to anchor unit to pad Installed on indoor coil z Condensing units and heat pumps with reciprocating or rotary compressors require the use of start -assist components when used in conjunction with an indoor coil using a non -bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit. The TXV should always be sized based on the tonnage of the outdoor unit. All AHRI system ratings are accessible in the System Configurator tool via Partnerl-ink. 22 www.goodmanmfg.com SS-GSXHS NOTES SS-GSXH5 www.goodmanmfg.com 23 NOTES Our continuing commitment to quality products may mean a change in specifications without notice. C2022 DA/K/NCOMFORT TECHNOLOGIES NORTHAMER/CA, INC. • Houston, Texas • Printed in the USA. 24 www.goodmanmfg.com SS-GSXH5