APPROVED ENG PLN_BLD RESUB 1-Architectural_Plan+7.23.2022GENERAL NOTES GENERAL REQUIREMENTS ALL WORK SHALL COMPLY WITH THE 2018 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN), INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE, INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE AND LOCAL AMENDMENTS. AND ANY APPLICABLE LAND USE CODE. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO CONSTRUCT A WEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE RESPONSIBILITY OF THE OWNER/BUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE. THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNER/BUILDER'S APPROVAL BEFORE BEING COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE INTENDED OWNER/BUILDER IS NOT PERMITTED. ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE. SITE WORK 1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. (1 1/2-3/8 CLEAN WASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE AND WATERPROOFING. 2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS BELOW FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES. 3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO ROOF AND STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDE TIGHT LINE CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES. 4. ROCKERIES AND RETAINING WALLS SHALL BE DESIGNED BY A LICENSED ENGINEER AND INSTALLED PER APPLICABLE CODE. MECHANICAL 1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT, EXPERIENCED PLUMBER AND IN ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES. 2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED MECHANICAL CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2018 IRC, AND LOCAL CODES. PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE THE GARAGE FLOOR. THERMAL AND MOISTURE 1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON PLANS OR ON A SEPARATE ENERGY CALCULATION SHEET. 2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION WALLS, FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE.. (R406.1) 3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER MANUFACTURER'S INSTRUCTIONS. 4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER IN ALL CRAWLSPACE AREAS, LAPPED AT ALL SPLICES AND OVER FOOTINGS. FINISHES GARAGE CEILINGS BENEATH HABITABLE SPACES SHALL BE COVERED WITH 5/8" TYPE "X" GYPSUM WALL BOARD. GARAGE CEILINGS BENEATH ATTIC OR NON LIVING SPACE SHALL BE COVER WITH 5/81, GYPSUM WALL BOARD. WALLS AND STRUCTURE SEPARATING RESIDENTIAL AND GARAGE SPACES SHALL BE COVERED WITH 1/2" GYPSUM WALL BOARD. ALL GARAGE GYPSUM WALLBOARD SHALL HAVE JOINTS FIRETAPED WITH NAILS SET AND COMPOUNDED. ALL OTHER WALLS SHALL RECEIVE 1/2" GYPSUM WALLBOARD. CEILINGS WITH JOISTS/ TRUSS SPACES GREATER THAN 16" SHALL RECEIVE 5/8" GYPSUM WALLBOARD OR 1/2" GYPSUM CEILING BOARD. WALLS SURROUNDING TUBS OR SHOWERS SHALL BE COVERED WITH WATER-RESISTANT GYPSUM WALL BOARD. WATER- PROOF SURFACE TO A HEIGHT OF 72" ABOVE ADJACENT FLOOR. ANY CEMENT PLASTER OR STUCCO SHALL BE INSTALLED IN ACCORDANCE WITH NORTHWEST WALL AND CEILING BUREAU RECOMMENDATIONS FOR MATERIALS, BACKING, LATH, APPLICATION TECHNIQUES, AND FINISHES. ELECTRICAL SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY. FIRESTOPPING FIRESTOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. FIRESTOPPING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING LOCATIONS: 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES NOT TO EXCEED 10'-0" HORIZONTALLY, AND AT THE CEILING AND FLOOR LEVEL. 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND WALL CAVITIES IN LINE WITH STRINGERS. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL, WITH NON-COMBUSTABLE MATERIALS. MISCELLANEOUS 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. 2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND ELECTRICAL WORK. 3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314) CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE BEDROOMS. (R315) 4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS. 5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. ROOF FLASHING PER R903. 6. GUARDRAILS TO BE A MIN. OF 36" ABOVE FINISH FLOOR. (R312) (EXCEPTIONS TO COMMERCIAL PER I.B.C.) 7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN DIAMETER CANNOT PASS THROUGH. 8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT OF 44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310.1). AREA CALCULATIONS HEATED AREAS SQUARE FOOTAGE 2ND FLOOR 1530 MAIN FLOOR 1470 BASEMENT (A.D.U.) 797 BASEMENT COMMON SPACE 129 TOTAL 3926 NON -HEATED AREAS SQUARE FOOTAGE GARAGE 665 DECK (EXISTING - NO CHANGE) 216 COVERED FRONT PORCH 160 DRAWING INDEX SHEET NO. DESCRIPTION Al COVER SHEET, INDEX, GENERAL NOTES A2 ENERGY CALCULATIONS ELEVATIONS A3 A4 ELEVATIONS A5 BASEMENT FLOOR PLAN A6 1 ST FLOOR PLAN A7 2ND FLOOR PLAN A8 A9 BUILDING SECTIONS AND MISC. DETAILS MISC. WALL AND CEILING DETAILS S1 STRUCTURAL NOTES/SCHEDULES S2 SHEAR WALLS AND HOLDOWNS S3 FOUNDATION PLAN S4 MAIN FLOOR FRAMING S5 2ND FLOOR FRAMING ROOF PLAN S6 S7 STRUCTURAL DETAILS S8 STRUCTURAL DETAILS S9 STRUCTURAL DETAILS SYMBOL LEGEND OO CARBON MONOXIDE DETECTOR INTERCONNECTED 110v w/ BATTERY BACKUP C.O. CAN BE COMBINED w/ S.D. O SMOKE DETECTOR INTERCONNECTED 110v w/ BATTERY BACKUP S.D. O EXHAUST FAN (VENT TO OUTSIDE) OKEYNOTE 101 DOOR SCHEDULE SYMBOL 1i WINDOW SCHEDULE SYMBOL Al REVISION- SEE DESCRIPTION IN TITLE BLOCK BAILEY & PAWLING RESIDENCE 755 DALEY STREET., EDMONDS., WA 98020 Approved by Fire 08/09/2022 AFM fCF�tterer Approved. A residential fire sprinkler system is required. A recommended flow -through design will meet specifications and reduce equipment and continuing maintenance requirements. ECDC19.05.020C. Provide a minimum combination water service of one inch (1 ") meter and one and one half (11/2") service line, or show that domestic and fire protection needs can be met with a smaller service. 7 ENGINEERING DIVISION APPROVED BY PLANNING APPROVED AS NOTED e)eVV 09/28/2022 Aug 08 2022 I SPECIAL INSPECTION REPORT REQUIRED FOR THIS PERMIT: i i-Soils i -Footings bear on competent native soil per the "Foundations" section above ■ -Footing reinforcement -Shear wall sill plate anchors and washers per schedule -Shear wall nailing and shear clips per schedule -Shear wall hold -dawns I -Verify type, size and grade of structural steel members and bolts I I I I I I ■ SIM DETAIL SYMBOL ALL WORK SUBJECT 1 SIMILAR DETAIL TO FIELD 101 DETAIL NO. INSPECTION FOR SHEET NO. CODE COMPLIANCE 1 SIM BUILDING CROSS SECTION A10 OBTAIN ELECTRICAL DETAIL NO. PERMIT FROM SHEET NO. STATE LABOR & INDUSTRIES Room name — ROOM NAME Know what's below. STATE LAW REQUIRES THAT YOU CALL BEFORE YOU DIG TO Call before you dig. LOCATE ALL UNDERGROUND UTILITIES. APPROVED PLANS MUST BE ON JOB SITE City Of Edmonds Building Department Work NEW SFR AND ADU Address 755 DALEY ST Owner PAWLING •------------------------------------------------- -------------- ----- Approved Date 8/o9/2022 Building Official r Permit Number BLD2021-i 667 d Z _ CD �co co Z QE 0 a �o 1' 2 a) IL uaW w r N O J LO U ��� co CO Z CD C W Cj LU 6 ix 0 LU m 0 LU a 2 E O t� C ,1 N d ? c o 0 `o oT�2@ Tfl"m N o ZaJ p �o O O LL m 0 CC Q N E y LU 0Ow LUoocyi U o�c3`�@ o� o>.w U J J F m � n o 0 0- a"� m 0 m a o LUOmoaa�`"i -o E ma`>s a Zo.o RESUB Jul 25 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W J Q m 06 o CD Z 00 01 J � W � H V Q Z Z O W :E Q Z W H W LU W LULUU LU h Z LU�a F LU LU �o O noZ z o ,n Q oV ^ 0 m c 0 .0 a� 0 z PROJECT NO. 200302 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. Al PRINT DATE 7/22/2022 5:38:05 PM R301 CLIMATE ZONE THIS PLAN IS DESIGNED FOR CLIMATE ZONE 5 AND MARINE 4 PER TABLE R301.1, 2018 WASHINGTON STATE ENGERY CODE. R402.2 FENESTRATION (PRESCRIPTIVE) R402.3 Fenestration (Prescriptive). In addition to the requirements of Section R402, fenestration shall comply with Sections R402.3.1 through R402.3.6. R402.3.1 U-factor. An area -weighted average of fenestration products shall be permitted to satisfy the U-factor requirements. R402.3.2 Glazed fenestration SHGC. An area -weighted average of fenestration products more than 50 percent glazed shall be permitted to satisfy the SHGC requirements. R402.3.3 Glazed fenestration exemption. Up to 15 square feet (1.4 m2) of glazed fenestration per dwelling unit shall be permitted to be exempt from U-factor and SHGC requirements in Section R402.1.1. This exemption shall not apply to the U- factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4. R402.3.4 Opaque door exemption. One side -hinged opaque door assembly up to 24 square feet (2.22 m2) in area is exempted from the U-factor requirement in Section R402.1.1. This exemption shall not apply to the U-factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4 R404.1 LIGHTING EFFICACY MIN. OF 75%OF LAMPS IN PERMANENTLY INSTALLED FIXTURES SHALL BE HIGH EFFICACY LAMPS. M 1507 MECHANICAL VENTILATION M1507.3.1 SYSTEM DESIGN. EACH DWELLING UNIT OR GUESTROOM SHALL BE EQUIPPED WITH A VENTILATION SYSTEM COMPLYING WITH SECTION M1507.3.4, M1507.3.5, M1507.3.6 OR M1507.3.7. COMPLIANCE IS ALSO PERMITTED TO BE DEMONSTRATED THROUGH COMPLIANCE WITH THE INTERNATIONAL MECHANICAL CODE. M1507.3.2 CONTROL AND OPERATION. 1. LOCATION OF CONTROLS. CONTROLS FOR ALL VENTILATION SYSTEMS SHALL BE READILY ACCESSIBLE BY THE OCCUPANT. 2. INSTRUCTIONS. OPERATING INSTRUCTIONS FOR WHOLE -HOUSE VENTILATION SYSTEMS SHALL BE PROVIDED TO THE OCCUPANT BY THE INSTALLER OF THE SYSTEM. 3. LOCAL EXHAUST SYSTEMS. LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS. 4. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS SHALL OPERATE CONTINUOUSLY. EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS SHALL BE EQUIPPED WITH "FAN ON" AS OVERRIDE CONTROLS. CONTROLS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES. A LABEL SHALL BE AFFIXED TO THE CONTROLS THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)." 5. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS SHALL COMPLY WITH THE FOLLOWING: 5.1. THEY SHALL BE CAPABLE OF OPERATING INTERMITTENTLY AND CONTINUOUSLY. 5.2. THEY SHALL HAVE CONTROLS CAPABLE OF OPERATING THE EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. 5.3. THE VENTILATION RATE SHALL BE ADJUSTED ACCORDING TO THE EXCEPTION IN SECTION 403.8.5.1. 5.4. THE SYSTEM SHALL BE DESIGNED SO THAT IT CAN OPERATE AUTOMATICALLY BASED ON THE TYPE OF CONTROL TIMER INSTALLED. 5.5. THE INTERMITTENT MECHANICAL VENTILATION SYSTEM SHALL OPERATE AT LEAST ONE HOUR OUT OF EVERY FOUR. 5.6. THE SYSTEM SHALL HAVE A MANUAL CONTROL AND AUTOMATIC CONTROL, SUCH AS A 24-HOUR CLOCK TIMER. 5.7. AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL SHALL BE SET TO OPERATE THE WHOLE -HOUSE FAN ACCORDING TO THE SCHEDULE USED TO CALCULATE THE WHOLE -HOUSE FAN SIZING. M1507.3.4 WHOLE -HOUSE VENTILATION USING EXHAUST FANS. THIS SECTION ESTABLISHES MINIMUM PRESCRIPTIVE REQUIREMENTS FOR WHOLE -HOUSE VENTILATION SYSTEMS USING EXHAUST FANS. A SYSTEM WHICH MEETS ALL THE REQUIREMENTS OF THIS SECTION SHALL BE DEEMED TO SATISFY THE REQUIREMENTS FOR A WHOLE -HOUSE VENTILATION SYSTEM. M1507.3.4.1 WHOLE -HOUSE VENTILATION FANS. EXHAUST FANS PROVIDING WHOLE -HOUSE VENTILATION SHALL HAVE A FLOW RATING AT 0.25 INCHES WATER GAUGE AS SPECIFIED IN TABLE M1507.3.3(1). MANUFACTURERS' FAN FLOW RATINGS SHALL BE DETERMINED ACCORDING TO HVI 916 OR AM CA 210. M1507.3.4.2 FAN NOISE. WHOLE -HOUSE FANS LOCATED 4 FEET OR LESS FROM THE INTERIOR GRILLE SHALL HAVE A SONE RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE. MANUFACTURER'S NOISE RATINGS SHALL BE DETERMINED AS PER HVI 915 (MARCH 2009). REMOTELY MOUNTED FANS SHALL BE ACOUSTICALLY ISOLATED FROM THE STRUCTURAL ELEMENTS OF THE BUILDING AND FROM ATTACHED DUCT WORK USING INSULATED FLEXIBLE DUCT OR OTHER APPROVED MATERIAL. M1507.3.4.3 FAN CONTROLS. THE WHOLE -HOUSE VENTILATION FAN SHALL MEET THE REQUIREMENTS OF SECTION M1507.3.2 AND M1507.3.2.1. M1507.3.4.4 OUTDOOR AIR INLETS. OUTDOOR AIR SHALL BE DISTRIBUTED TO EACH HABITABLE SPACE BY INDIVIDUAL OUTDOOR AIR INLETS. WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT TO A MINIMUM OF 1/2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING. INDIVIDUAL ROOM OUTDOOR AIR INLETS SHALL: 1. HAVE CONTROLLABLE AND SECURE OPENINGS; 2. BE SLEEVED OR OTHERWISE DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES OF THE WALL OR WINDOW IN WHICH THEY ARE PLACED; 3. PROVIDE NOT LESS THAN 4 SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH HABITABLE SPACE. ANY INLET OR COMBINATION OF INLETS WHICH PROVIDE 10 CFM AT 10 PASCALS ARE DEEMED EQUIVALENT TO 4 SQUARE INCHES NET FREE AREA. INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR OTHER MATERIAL. OUTDOOR AIR INLETS SHALL BE LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING AREAS: 1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 FEET ABOVE THE OUTDOOR AIR INLET. 2. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS. 3. A HAZARDOUS OR UNSANITARY LOCATION. 4. A ROOM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN. 5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET. 6. ATTIC, CRAWL SPACES, OR GARAGES. II� 'ABLE 11 605.4.3(1) WHOLE -HOUSE NIECHANICAL VENTILATION AIRFLOW RATE N um1)er of Bed l-ooms Dwelling Unit Floor Area (square feet.) 0- -1 1 2 1 3 1 4 1 5 or. 11-101'(1 Airflow in cfnl .600 210 30 35 45 51CI 501 - 1,000 3C1 3r. 40 64 r_-,E 1,001 -1,600 '.II 40 45 555 _; I 15C I - 2,.000 45 60 60 2,001 - 2.600 41 I 50 55 65 7':] 2,501 - 3.000 46 E. 60 70 75 3,001 - 3,500 50 60 65 75 3,501 - 4,000 55 65 70 80 SF1 4,001 - 4,500 60 70 75 85 90 4,501 - 5,000 65 7F 80 90 95 TABLE M1505.4.3 (3) INTERMITTENT WHOLE HOUSE MECHANICAL VENTILATION RATE FACTORS RUN-TIME PERCENTAGE IN EACH 4-HOUR SEGMENT 50% 66% 75% 100% FACTOR 2 1.5 1.3 1.0 M1505.4.3.2 Intermittent off operation. Whole -house mechanical ventilation systems shall be provided with advanced controls that are configured to operate the system with intermittent off operation shall operate for a least two hours in each four-hour segment. The whole house ventilation airflow rate determined in accordance with Section M1505.4.3 as corrected by Section M1505.4.3.1 is multiplied by the factor determined in accordance with Table M1505.4.3(3). THIS PLAN USES AN INTERMITTENT WHOLE HOUSE VENTILATION SYSTEM WITH TIMER(s). TOTAL HEATED FLOOR AREA = 3923 SQ. FT. BEDROOMS = 5 WHOLE HOUSE VENTILATION SIZE = 85 CFM X 2 (50% PER 4-HOUR) = 170 TOTAL CFM FAN(s) SIZE. INTEGRATED FURNACE OUTSIDE AIR INTAKE WITH EXHAUST FANS AS NOTED IN PLAN. MULTIPLE WHOLE HOUSE VENTILATION FANS TO BE INTERCONNECTED TO OPERATE SIMULTANEOUSLY. 2018 WASHINGTON STATE ENERGY CODE MISC. ENERGY CODE NOTES A permanent certificate shall be completed and posted on or within three feet of the electrical distribution panel by the builder or registered design professional. The certificate shall be completed by the builder or registered design professional and shall not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, below -grade wall, and/or floor) and ducts outside conditioned spaces; U-factors for fenestration and the solar heat gain coefficient (SHGC) of fenestration, and the results from any required duct system and building envelope air leakage testing done on the building. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the types and efficiencies of heating, cooling and service water heating equipment. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Where the primary heating system is a forced -air furnace, at least one thermostat per dwelling unit shall be capable of controlling the heating and cooling system on a daily schedule to maintain different temperature set points at different times of the day. Specifics and Exceptions see SEC. ALL DUCTWORK SHALL BE SEALED AND TESTED PER R403.2.2. WINDOW AND DOOR HEADERS SHALL BE INSULATED WITH R-10 RIGID INSULATION EXCEPT IN SITUATIONS WHERE STRUCTURAL BEAM SIZE REQUIREMENTS OVERRIDE. ALL APPLIANCES SHALL BE U.L. LISTED. WHOLE HOUSE FANS Whole house ventilation fans shall be installed so as to run simultaniously. EXHAUSTFANS Exhaust fans to terminate at building exterior with clearances per SRC M1506.2 (min. 3 ft to openings) and for clothes dryer vent terminations to be per M1502.3 (3 ft to bldg. openings). ALL FENESTRATION SHALL BE NFRC CERTIFIED. 2x6 TOP PLATES i.W.B. ;ID R-10 INSULATION kLLED IN CAVITY BETWEEN ER AND INTERIOR G.W.B. ER PER PLAN .-OW, FINISH & TRIMS PER MISC. DETAILS HEADER INSULATION 1 1/2" = V-0" PRESCRIPTIVE ENERGY CODE COMPLIANCE 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Version 1.0 These requirements apply to all IRC building types, including detached one- and two-family dwellings and multiple single-family dwellings (townhouses). Project Information Contact Information 755 DALEY STREET, EDMONDS, WA HELLEREN CONSTRUCTION Instructions: This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings: Table R402.1- Insulation and Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits. Authorized Representative �Date8/09/2021 All Climate Zones (Table 11402.1.1) R-Valuea U-Factors Fenestration U-Factor b n/a 0.30 Skylight U-Factor b n/a 0.50 Glazed Fenestration SHGC bje n/a n/a Ceiling a 49 0.026 Wood Frame Wall s,h 21 int 0.056 Floor 30 0.029 Below Grade Wall `,h 10/15/21 int + TB 0.042 Slab d,f R-Value & Depth 10, 2 ft n/a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less a than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. "10/15/21 +5TB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement wall. "10/15/21 +5TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5T13" means R-5 thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1. For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth e extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for g climate zone 5 of ICC 400. Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard h framing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 1 FENENSTRATION CALCULATIONS HEATING SYSTEM SIZE VERTICAL GLAZING 460 SF Simple Heating System Size: Washington State LESS EXEMPT GLAZING -00 SF This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. GLAZED DOORS PLUS OTHER EXTERIOR DOORS 198 SF Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at TOTAL FENESTRATION: 658 SF energycode@energy.wsu.edu or (360) 956-2042 for assistance. NOTE: SEE SHEET A8 FOR ADDITIONAL INSULATION LOCATIONS AND DETAILS, OPTION HEATING 2 ENERGY CREDITS Project Information Contact Information BAILEY & PAWLING RESIDENCE LEIF HELLEREN - HELLEREN CONSTRUCTION "Ieating Syst-m Type: O All Other Systems :•- Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) 46 Edmonds �T = Indoor (70 degrees) - Outdoor Design Temp el- .a of R' i,lrli,nr Conditioned Floor Area Iustruutions Conditioned Floor Area (sq ft) 3,923 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.3 32,365 Glazing and Doors U-Factor X Area = UA Instructions CUO.28 0.280 658 184.24 Skylights DESCRIPTION CREDIT Instructions HEAT PUMP - ELECTRIC 1.0 Insulation Attic ENERGY Prescriptive compliance is based on Table R402.1.1 with the following 0.5 1.3 modifications: Vertical fenestration U = 0.28 Floor R-38, Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab ENERGY Compliance based on R402.4.1.2: 0.5 2.1 Reduce the tested air leakage to 3.0 air changes per hour maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a high efficiency fan(s) (maximum 0.35 watts/cfm), not interlocked with the furnace fan (if present). Ventilation systems using a furnace including an ECM motor are allowed, provided that they are controlled to operate at low speed in ventilation only mode. ENERGY Air -source centrally ducted heat pump with minimum HSPF of 9.5 1.0 3.2 Instructions R-38Advanced • Single Rafter or Joist Vaulted Ceilinqs Instructions No Vaulted Ceilings in this project. -,r Above Grade Walls (see Figure 1) Instructions R-21 Intermediate . t Floors Instructions R-38 i Below Grade Walls (see Figure 1) nstructions R-211nterior . Slab Below Grade (see Figure 1) 'nstructions R-10 Fully insulated � Slab on Grade (see Figure 1) Instruction z L R-10 Fully Insulated Location of Ducts Instructions U-Factor X Area = UA 0.50 0� --- U-Factor X Area = 0.026 1,652 U-Factor X Area --- 0 U-Factor X Area 0.056 2,608 U-Factor X Area 0.025 773 U-Factor X Area 0.042 343 F-Factor X Length 0.303 45 F-Factor X Length 0.360 66 UA 42.95 UA UA 146.05 UA 19.33 UA 14.41 UA 13.48 UA 23.76 Conditioned Space Duct Leakage Coefficient 1.00 ENERGY HVAC equipment and associated duct system(s) installation shall 1.0 4.2 comply with the requirements of Section R403.3.7. Locating system components in conditioned crawl spaces is not Figure 1 permitted under this option. Electric resistance heat and ductless heat pumps are not permitted under this option. Above Grade Direct combustion heating equipment with AFUE less than 80% is not permitted under this option. ENERGY Water heating system shall include one of the following: 2.0 5.5 Electric heat pump water heater meeting the standards for Tier III of NEEA's advanced water heating specification 6.0 TOTAL 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit: credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit: 6 credits All dwelling units that are not included in #1 or #3 3. Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. Summary of Table R406.2 Heating Credits - select ONE Options Fuel Normalization Descriptions heating option User Notes 1 Combustion heating minimum NAECAb 0.0 ❑ 2 Heat pump` 1.0 0 3 Electric resistance heat only - furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3.4 0.5 ❑ 5 All other heating systems -1.0 ❑ Energy Options p Energy Credit Option Descriptions EffmEMMMM TRIM Mm lmlam Efficient Building Envelope Efficient Building Envelope Efficient Building Envelope Credits - select ONE energy option from each category 0.5 ❑ 1.1 1.2 1.0 ❑ 1.3 0.5 1.4 1.0 ❑ 1.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope ❑ 0.5 ❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 0 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ 2.4 Air Leakage Control and Efficient Ventilation Li 2.0 ❑ 3. la High Efficiency HVAC 1.0 ❑ 3.2 High Efficiency HVAC 1.0 17 3.31 High Efficiency HVAC 1.5 ❑ 3.4 High Efficiency HVAC High Efficiency HVAC High Efficiency HVAC 1.5 ❑ 3.5 1.5 ❑ 3.6- 2.0 ❑ 4.1 High Efficiency HVAC Distribution System 4.2 High Efficiency HVAC Distribution System 0.5 ❑ 1.0 Prescriptive Path - Single Family 2018 Washington State Energy Code-R 2 Sum of UA 444.21 Envelope Heat Load 20,434 Btu / Hour Sum of UA x AT Air Leakage Heat Load 16,079 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 36,513 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 36,513 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 45,641 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) 1J Summary of Table R406.2 (cont.) Energy Options Energy Credit Option Descriptions (cont.) Efficient Water Heating Efficient Water Heating Efficient Water Heating Credits - select ONE energy option from each category d 0.5 ❑ 0.5 ❑ 1.0 ❑ User Notes 5.1d 5.2 5.3 5.4 Efficient Water Heating 1.5 ❑ 5.5 Efficient Water Heating 2.0 0 5.6 Efficient Water Heating 2.5 ❑ 6. le Renewable Electric Energy (3 credits max) 1.0 Q 7.1 Appliance Package 0.5 ❑ Total Credits 1 6.0 ICalculate Total l I Clear Form I a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4) or C403.3.2(5) c. Equipment listed in Table C403.3.2(1) or C403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category 5. Option 5.1 may be combined with options 5.2 through 5.6. See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group. Please print only pages 1 through 3 of this worksheet for submission to your building official. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 3 (07101113) V Z N CD CD Z a E Q � o U Y = to Lo a) Lo O U JL� 2M� co e6 00 Z o.. LU � F0 im XO a) LU m p LU a H E V 'c� C i. IIIJJ L y, o Z J o o '0 W 6-6 m m r o m a n N 0-in .3 F G L U E N CCOLL,ZoQ 0� m Ty �r=m u.-E y 0Ow�W oocy>`r'F0 Lai U o>.N o�c3`>':-oo� UJ�F m� �-00 o-a m0 m� o uu O a. w" = zoy RESUB Jul 25 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W J 06 O CV CD Z 00 01 W 3:: H U o Z 0. O W Q Z W H W LU W LULU I-- H w loc U h Q W z W LUW LU � o Z o ,n OZ O V o- Q ll at iu c 0 Ln 6 z PROJECT NO. 200302 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A2 PRINT DATE 1 1 /26/2021 10:12:34 AM SOUTHEAST PERSPECTIVE SOUTHWEST PERSPECTIVE. Shingles WeatherSeal trowel -applied membrane 7— NO flashing raped and sealed Wall sheathing Kick -out flashing Klck-out and fascia taped and sealed 2� KICKOUT FLASHING �DETAIL NOTE! SURVEY REQUIRED TO VERIFY BUILDING HEIGHTS PER CITY OF EDMONDS. OUR RECOMMENDATION IS TO ALSO FIELD VERIFY HEIGHTS AT START OF CONSTRUCTION AS FLOOR LEVELS ARE ESTABLISHED. ELEVATION NOTES PROVIDE METAL FLASHING OVER TOPS OF WINDOWS AND TOPS OF TRIMS DIRECTLY EXPOSED TO WEATHER. ROOFING MATERIAL, SIDING AND FLASHING SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, INDUSTRY STANDARDS AND PER I.R.C. PORCHES, BALCONIES, RAMPS OR RAISED SURFACES LOCATED MORE THAN 301, ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36" IN HEIGHT. OPEN SIDE OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLY FROM THE NOSING OF THE TREADS. INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES SHALL BE SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. THE TRIANGLE OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM OF RAIL SHALL BE SUCH THAT A 6" SPHERE CANNOT PASS THROUGH. EXTERIOR STAIRS SHALL BE NOT LESS THAN 36" WIDE. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5" ON EITHER SIDE OF THE STAIRWAY AND MIN. CLEAR WIDTH AT OR BELOW THE HANDRAIL SHALL NOT BE LESS THAN 31.5". MAX. RISER HEIGHT IS 7 3/4". MIN. TREAD DEPTH SHALL BE 10". A LANDING IS REQUIRED AT TOP AND BOTTOM OF EACH STAIRWAY. SITE ADDRESS SHALL BE VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. NUMBERS SHALL CONTRAST WITH BACKGROUND, BE ARABIC NUMBERS OR ALPHABETICAL LETTERS, BE A MIN. OF 4" IN HEIGHT WITH A MIN. STROKE WIDTH OF 1/2". (R319.1) LO 0 00 ED N bo 65 41 43 84) (1RC(` (_1 Ace /AI I A AT TI-IIQ %A/AI 1 1 IAIC\ MINIM MINIM MINIM MINIM MINIM III III III III III Max. Height 125'-0" 70 2ND FLOOR PLATE 123'-57/8" ol 2N_D FLOOR 115'-97/8" 1 ST FLOOR PLATE n 114' - 9 1 /4" _ _1ST FLOOR t 106' - 1 1 /4" ENT FLOOR PLATE t1 105' - 3 1 /4" 72 I y Ave 'aa a Grade 100'-0" BASEMENT FLOOR 97' -.1 1 /4" III III III III III - SOUTH ELEVATION 1/4" = 1'-0" ELEVATION KEYNOTES WEST ELEVATION KEY VALUE KEYNOTE TEXT (�4 1/4" = 11-011 39 40+ YEAR PRESIDENTIAL RANDOM CUT ARCHITECTURAL COMPOSITION ROOFING 41 CONTINUOUS ALUMINUM GUTTER ON 5/46 FASCIA 43 T.P.O. MEMBRANE ROOF WITH PARAPET AND METAL FLASHING PER DETAIL. 45 FASCIA: 1x4 ON 5/410 (TYPICAL AT GABLE ENDS) 50 HORIZONTAL BEVEL CEMENT BOARD SIDING PER BUILDER SPECS 51 SHINGLE SIDING WHERE INDICATED 53 5/44 CEDAR OR WHITE WOOD TRIM PER BUILDER SPECIFICATIONS. 58 2x10 CEDAR OR WHITE WOOD TRIM PER BUILDER SPECIFICATIONS. 60 SLIMLINE METAL CORNER TRIM. 61 2x10 BELLY BAND w/ METAL FLASHING 65 WINDOW WRAP: 5/44 (4) SIDES. PROVIDE HEAD FLASHING OVER ALL WINDOWS NOT UNDER EAVES AND/OR EXPOSED TO WEATHER. 71 BOX FRAME POST BASE AND WHITE WOOD TRIMS o/ STRUCTURAL POST PER PLAN 72 STONE OR BRICK VENEER WHERE INDICATED 76 P.T. DECK POSTS, JOISTS AND BEAMS PER PLAN 77 SPACED CEDAR DECKING PER PLAN 80 TEMP. GLASS STORE DOOR 81 TEMP. GLASS SLIDING PATIO DOOR. 83 PROVIDE 6" MINIMUM EARTH/WOOD CONTACT 84 TEMP. GL. 85 LOCKING DEADBOLD AT ENTRY DOOR 86 CONCRETE LANDING AND STEPS PER I.R.C./I.B.C. 87 INSULATED STEEL OVERHEAD GARAGE DOOR. MAKE AND STYLE PER BUILDER/OWNER SPECIFICATIONS. 94 TEMP. GLASS WINDOW. 96 PROVIDE METAL HEAD FLASHING ABOVE ALL WINDOWS EXPOSED TO WEATHER. V z — N co >_ 00 0) z Q E Q � U IL Y= W a 'w ww a O J U LO � (M CO � z ooN` LU � .Fu im 0 °�' LU m 0 a = H o 11rum - Z N a0.. C L_ N C U C w E O T fq N N ?: J y d E p Z J O C Q L y Nam C.V O H O p T p U E N C 0 OOmJ Q LLJ V ym O NN LN y Oa UC ETyN0aW Ep 3 O= O :N0 QWuj O UC QT "O 2Ua(Q5 O WH O2U� O O L 3 C Z ao w m d m o� E d RESUB Jul 25 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W a m 06 o N CD z 00 01 J � W � H U Q z z o W :E Q z W H W LU W LULU W U h Z W �a w W w �o o Z o Ln O z o Q^ 0 0 .N 0 z PROJECT NO. 200302 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A3 PRINT DATE 11 /26/2021 10:15:39 AM Step 1: Prepare the WRB at the rough opening: install a small section of house wrap below the sill (referred to as an "apron"); alternatively, install self-adhesive pan flashing with split backing (where the release paper backing can be removed incre- mentally) to seal to the house wrap later. Step 2: Install pan flashing: cover the rough sill and extend onto the face of the wall/ WRB. Step 3: Install the window: according to manufacturer instructions. Step 4: Install the jamb flashing: over window flange and pan flashing and extend above the head flange. Step 5: Install the head flashing: over and beyond the jamb flashing (and over the win- dow drip cap if installed). Step 6: Integrate the WRB: Install house wrap shingle -fashion, integrated with the apron, and seal house wrap at jambs and head using sealant (beneath the house wrap) or construction tape. HEAD FLASHING NOTE: SEE NOTE BELOW DRAWING FOR INSTALLATION OF METAL HEAD FLASHING @ THIS AREA I WEATHER RESISTIVE BARRIER HYDROGAP DRAINABLE HOUSEWRAP (BENJAMIN OBDYKE) W/ BENJAMIN OBDYKE HYDROFLASH@ GP SILL / PENETRATION FLASHING AND BENJAMIN OBDYKE HYDROCORNER SILL FLASHING (APPROVED SUBSTITUTIONS OKAY) Housewrap V1LL 1 LLP l ZING NOTE: Rigid cap flashing 1) INSTALL BENJAMIN OBDYKE HYDROCORNER SILL FLASHING OR EQUIV. Flashing tape @ ALL WINDOW SILL CORNERS over head trim 2) INSTALL BENJAMIN OBDYKE HYDROFLASHO GP SILL / 10` to 15, PENETRATION FLASHING OR EQUIV. OVER CORNER SHIELD, AS slope EXTRA PREVENTION FOR LEAKS @ SILL CORNERS HEAD FLASHING NOTE: Flashing AT WINDOW HEAD METAL DRIP tape FLASHING: INSTALL METAL HEAD overtop \ FLASHING @ WINDOWS & EXTERIOR flangew DOORS PER THE DETAIL BELOW. Head trim Flashing tape over side window flange ,WINDOW FLASHING v % 1 /4" = V-0" ELEVATION KEYNOTES KEY VALUE KEYNOTE TEXT 39 40+ YEAR PRESIDENTIAL RANDOM CUT ARCHITECTURAL COMPOSITION ROOFING 41 CONTINUOUS ALUMINUM GUTTER ON 5/46 FASCIA 43 T.P.O. MEMBRANE ROOF WITH PARAPET AND METAL FLASHING PER DETAIL. 45 FASCIA: 1x4 ON 5/4x10 (TYPICAL AT GABLE ENDS) 50 HORIZONTAL BEVEL CEMENT BOARD SIDING PER BUILDER SPECS 51 SHINGLE SIDING WHERE INDICATED 53 5/4x4 CEDAR OR WHITE WOOD TRIM PER BUILDER SPECIFICATIONS. 58 2x10 CEDAR OR WHITE WOOD TRIM PER BUILDER SPECIFICATIONS. 60 SLIMLINE METAL CORNER TRIM. 61 2x10 BELLY BAND w/ METAL FLASHING 65 WINDOW WRAP: 5/4x4 (4) SIDES. PROVIDE HEAD FLASHING OVER ALL WINDOWS NOT UNDER EAVES AND/OR EXPOSED TO WEATHER. 71 BOX FRAME POST BASE AND WHITE WOOD TRIMS o/ STRUCTURAL POST PER PLAN 72 STONE OR BRICK VENEER WHERE INDICATED 76 P.T. DECK POSTS, JOISTS AND BEAMS PER PLAN 77 SPACED CEDAR DECKING PER PLAN 80 TEMP. GLASS STORE DOOR 81 TEMP. GLASS SLIDING PATIO DOOR. 83 PROVIDE 6" MINIMUM EARTH/WOOD CONTACT 84 TEMP. GL. 85 LOCKING DEADBOLD AT ENTRY DOOR 86 CONCRETE LANDING AND STEPS PER I.R.C./I.B.C. 87 INSULATED STEEL OVERHEAD GARAGE DOOR. MAKE AND STYLE PER BUILDER/OWNER SPECIFICATIONS. TEMP. GLASS WINDOW. 94 96 PROVIDE METAL HEAD FLASHING ABOVE ALL WINDOWS EXPOSED TO WEATHER. '/a -in. gap beneath siding Max. Height 125'-0" u? 0 2ND FLOOR -1 11ti'_Q7/R/R"� 114'-9114 0 1ST FR LOO 106' - 1 1 /411 BASEMENT FLOC 43 41 _ jh Max. Height _ _ _ _ _ _ ANDFASCDETAIR (S E A8SECTION 125'-0" _2ND FLOOR PLATE 123' - 5 7/8" I — 22 12 OD 60 co 50 0 61 45 2ND FLOOR 115'-97/8" 1ST FLOOR PLATE 114' - 9 1 /4" 94 1/2 LITE DOOR 00 10 bo 60 81 D 15 84 51 ILLI EXISTING DECK AND STEPSCD 1ST FLOOR � --- EXISTING GRADE 106' - 1 1//44" BASEMENT FLOOR PLATE 105' - 3 1 /4" 83 i� Average Grade + 100, - 0" -A-� Y� _BASEMENT FLOOR III III III III III III III III III III III III III III III III III III III III III III III III II NORTH ELEVATION 1/4" = 1'-011 2ND FLOOR PLATE 123' - 5 7/8" all- 00 J Average Grade 2680 - 83 - BASEMENT FL00 _ t 97' --1 1 /4" — III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III- ��, EAST.E LE V.A T1 O�N i 1 /4" = 1'-0" V z N co O 00 W z Q E Q � U IL Y = a, W d 'w W ,n N � a O _LJ J� U �rn� z (000N` LU 0 °) LU M 0 LU a H E AIL � V Ti! C y 4) L U y c t m y v$ w o oZ�o�oc02�ammN=odn�. c�1 a A o H o a T 9 2 U E m c cQ Q O LL V y` U U U .2 `p N y C N.L. .505 2 N N= N w L= N 5.9 E N EL Zo Edy�c adS�mm a= 0 Q W U O p 2 C U Q T N 01 C 3 C ,6 U U U J J 0'.. y o U a 6�(6 N Q N� 2 W OMUaN'O EN�U123C � Zao"�m d: OHE`°°� RESUB Jul 25 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W Q m 06 o N CD z 00 01 W � H U Q z z O W :E Q z W H W LU W W W LUULU Z W �a LU LU w �o z o ,n O zO 0 Q cu cu 0 .N 0 z PROJECT NO. 200302 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A4 PRINT DATE 11 /26/2021 10:15:55 AM DOOR SCHEDULE - BASEMENT FLOOR SYM. NO. WIDTH HEIGHT DOOR TYPE COMMENTS BASEMENT FLOOR D1 3' - 0" 6'- 8" SINGLE ENTRY- CONTEMPORARY (TEMP.) TEMP. GLASS (U=0.28) D2 2'- 8" 6'- 8" SINGLE PANEL D3 2'- 8" 6'- 8" SINGLE PANEL D4 2'- 8" 6'- 8" SINGLE PANEL D5 2'- 6" 6'- 8" SINGLE POCKET D6 2'- 6" 6'- 8" SINGLE PANEL D7 2'- 8" 6'- 8" SINGLE PANEL D8 2' - 8" 6' - 8" SINGLE PANEL 1 3/8" SOLID CORE w/ SELF CLOSING MECHANISM D9 5'- 0" 6'- 8" BI-PASS CLOSET DOOR D10 2'- 8" 6'- 8" SINGLE PANEL 1 3/8" SOLID CORE w/ SELF CLOSING MECHANISM D11 2'- 8" 6'- 8" SINGLE PANEL D12 8'- 0" T - 0" OVERHEAD GARAGE DOOR INSULATED STEEL OVERHEAD DOOR D13 16' - 0" T - 0" OVERHEAD GARAGE DOOR INSULATED STEEL OVERHEAD DOOR D39 3' - 0" 6' - 8" SINGLE ENTRY - CONTEMPORARY (TEMP.) TEMP. GLASS (U=0.28) WINDOW SCHEDULE - BASEMENT FLOOR SYM. NO. WIDTH HEIGHT AREA WINDOW TYPE U-VALUE COMMENTS BASEMENT FLOOR 1 16'- 0" 4' - 0" 24 SF SLIDER 0.28 TEMP. GL. 26 1' - 4" 16'- 0" 8 SF I PICTURE (FIXED) 10.28 1 TEMP. GL. Grand total 32 SF KEYNOTE SCH ELDU LE KEY VALUE TEXT 01 GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE OR 20 MIN. FIRE RATED RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING DEVICE. (R302.5.1) 02 LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 03 GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 & TABLE 302.6) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503) 06 GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) 07 STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6) 08 EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECS. AND IN STRICT ACCORDANCE W/ LOCAL BUILDING 09 CODES. MUST BE U.L. LISTED. (M1303/ G2427.2.1) 10 DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 12 PILOTS, BURNERS, & SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. 17 CLOSET ROD w/ VINYL COATED WIRE SHELF CLOSET SHELVING AND DRAWER ORGANIZERS PER BUILDER SPECS. 18 19 TEMP. GLASS DOOR 20 TEMP. GLASS WINDOW 22 ONE PIECE SHOWER WITH TEMP. GLASS SHOWER DOOR. 24 FIBERGLASS TUB w/ TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFICATIONS. 27 1/2" GWB UNDER STAIRWAY IN ENCLOSED SPACES. 28 HYDROBLOK OR EQUIV. SHOWER PAN w/ TILE SURROUND. PROVIDE TEMP. GLASS DOOR AND ENCLOSURE. CENTER OR CONCEALED FLOOR DRAIN PER BUILDER/OWNER SPECS. 29 TEMPERED GLASS SHOWER DOOR AND ENCLOSURE. 75 O O Q w Z 00 EO HANDRAIL, GUARD AND BALUSTERS TO CONFORM TO I.R.C. OPENINGS SPACED SUCH Th'"T CANNOTI 75 N M z O LU 10" MIN. Fy TREAD Cl) t` N II �� II II II I I I II II I II I II II FIRE BLOCK BETWEEN STUD 3/4" MIN; BAYS AT WALLS IN CONTACT 1 1/4" MAX. WITH STRINGERS. NOSING 1/2" MIN. PLYWOOD RISERS j) RESIDENTIAL STAIR -IRC i 3/4" = 1'-0" 8 — 0 7 — IDOOR IS TO BE A 20 MINUTE FIRE RATEDI DOOR AND ASSEMBLY. ■ RESIDENTIAL STAIRS TO BE 3 MIN. 36" (CLR) WIDE. 2 1 1/4" DIA. MIN; 2" DIA. MAX. HANDRAIL w/ RETURNS TO WALL. DBL. JOIST (U.N.O.IN PLAN) 1 - SIMPSON LUS210 JOIST HANGER �- - SIMPSON A35 EACH SIDE OF STRINGERS - (1) LAYER 1/2" GWB -- 2x12 STRINGERS PER PLAN T 2X4 STUD WALL 4'-6" 36' - 6" 32' - 0" 9'-3" B C D E F G H 12'-9" I I I Q ° - _ N ® co N D39 PATIO BATH D5 = N 8'X9' 60 -- o BEDROOM 1 r A2 ELECT. WALL HEATER D2 08 1 0 I 2x6 WALL 3' - 0" S.D. M D3 A.D.U. NTRY D1 02 LO V13:- 1-1-1/2" 5' - 10" ' CV 10 D7 D9 20 2 (2) LAYERS 5/8" TYPE "X" 0 0 O 17 GWB AT ADU CEILING. S.D. c.o. V.T.O. SEE DETAILS 3/A9 & 4/A9 Cl) STHEY APPLY. I I`liwi^ 1 HR. WALL.? VOID SPACE HEAT PUMP HEAD BETWEEN ADU D11 HANDRAIL AND MAIN HOUSE. 1 STACK WASHER 1 Up AND DRYER (V.T.O.) A9 A9 Q7 Lo O a0 cio. S.D. p •Z op 01 01 q D6 ii q A5 - NEW WALLS II II II q q (GREY FILLED) - I II II II q II D8 I II II II II II SUB -PANEL A.D.U. SHUTOFF INFILL EXISTING27 CC 3 O 12 02 — — DOOR 02 — — — ° 2 Electric heat pump water heater - STORA E meeting the standards for Tier III UNDER STAIRS of NEEA's advanced water heating 5 1/2" 6' - 0 1/2" 3' - 9" specification INTERCONNECTEDiI HEAT SENSOR PER ELECTRIC VEHICLE R 314.2.3 CHARGING STATION O - w/ 1 EV DESIGNATED INTERCONNECTED PARKING SPACE. HEAT SENSOR PER R 314.2.3 GARAGE 5/8" TYPE "X" GWB AT a, GARAGE CEILING UNDER HABITABLE SPACE ABOVE. PARTITION WALL — — - � — — —TA— 20'- 9 1/2' � WATER SHUT-OFF FOR A.D.U. ELECT. PANEL - MAIN HOUSE. LOCATION MAY -4 ° = CHANGE PER ELECTRICIAN. e � Q a CONCRETE STEPS, - 1' - 0" PLANTER AND BIO-CELL PER SITE PLAN. 8' -0" 2'-0" 16'-0" 2'-6' 2' -0 2' 0" 9'-6" 20'-6" BASEMENT FLOOR 1/4" = 1'-011 Cti 18 REFRIG.-_ PACE I 04IKITCHEN 4' 6" Of I 3'-6" 0' 2' 4' 8' 16' ELECT. HEAT V z N co O 00 W z Q E Q � U IL Y= u1aw a O U J LO � 0) M(O,O z 00N` LU ix 00 aai LU m 0 LU n 2 H E O U C + .N N a� �$ o Z gi o o O t y a,E o- c�am.'� 1 C5EtUa6 CNm�rNo° OOmQpcNCMC LL V w0aNU ya E wO ccW GU°wVo w O N O a N' E N _ L � C Z a w m d m o E d RESUB Jul 25 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W J Q m 06 o z c14 CD 00 01 W J � � U Q H z z O W :E Q z W H W LU W LUw W U Z W LU LU �a �o o O zO Z 0 o Ln Q a� 0 N N N U co Q N 0) C > w CC c a� 0 0 z N PROJECT NO. 200302 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A5 PRINT DATE 7/22/2022 5:36:55 PM DOOR SCHEDULE - 1ST FLOOR SYM. NO. WIDTH HEIGHT DOOR TYPE COMMENTS 1 ST FLOOR D14 3' - 0" 8' - 0" ENTRY DOOR w/ SIDELITES (TEMP.) SOLID CORE OR FIBERGLASS PER BUILDER SPECS. D15 12' - 0" 8'- 0" DBL SLIDING PATIO DOOR TEMP. GLASS (U=0.28) ANDERSON 200 SERIES PER BLDR. SPECS. D16 2'- 6" 6'- 8" SINGLE PANEL D17 5' - 0" 6-8" DOUBLE GLASS (TEMP.) D18 2'- 10" T - 0" SINGLE STORE DOOR (TEMP.) TEMP. GLASS (U=0.28) HALF LITE GLASS PER BUILDER SPECS. D36 3' - 0" 6'- 8" BARN STYLE DOOR TRACK AND FINISH PER OWNER D37 3' - 0" 6-8" BARN STYLE DOOR TRACK AND FINISH PER OWNER D38 12'- 4" 6' - 8" SINGLE PANEL WINDOW SCHEDULE - 1ST FLOOR SYM. NO. WIDTH HEIGHT 7 AREA WINDOW TYPE U-VALUE COMMENTS 1 ST FLOOR 2 4'- 0" 1'- 6" 6 SF PICTURE (FIXED) 0.28 3 4'- 0" 1'- 6" 6 SF PICTURE (FIXED) 0.28 4 3' - 0" 6'- 0" 18 SF SINGLE HUNG 0.28 5 3' - 0" 6'- 0" 18 SF SINGLE HUNG 0.28 6 3' - 0" 6-0" 18 SF SINGLE HUNG 0.28 7 3' - 0" 6' - 0" 18 SF SINGLE HUNG 0.28 8 8'- 0" 1'- 6" 12 SF DOUBLE SLIDER 0.28 9 8'- 0" 4'- 6" 36 SF DOUBLE SLIDER 0.28 10 4'- 0" 6'- 0" 24 SF PICTURE (FIXED) 0.28 TEMP. GL. 11 8'- 0" 5'- 0" 40 SF DOUBLE SLIDER 0.28 27 4'- 0" 1'- 6" 6 SF SLIDER 0.28 OBSCURED GLASS Grand total 202 SF KEYNOTE SCHELDULE KEY VALUE TEXT 01 GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE OR 20 MIN. FIRE RATED RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING DEVICE. (R302.5.1) 02 LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 03 GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 & TABLE 302.6) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503) 06 GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) 07 STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6) 08 EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) 09 DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECS. AND IN STRICT ACCORDANCE W/ LOCAL BUILDING CODES. MUST BE U.L. LISTED. (M1303/ G2427.2.1) 10 DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 12 PILOTS, BURNERS, & SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. 17 CLOSET ROD w/ VINYL COATED WIRE SHELF 18 CLOSET SHELVING AND DRAWER ORGANIZERS PER BUILDER SPECS. 19 TEMP. GLASS DOOR 20 TEMP. GLASS WINDOW 22 ONE PIECE SHOWER WITH TEMP. GLASS SHOWER DOOR. 24 FIBERGLASS TUB w/ TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFICATIONS. 27 1/2" GWB UNDER STAIRWAY IN ENCLOSED SPACES. 28 HYDROBLOK OR EQUIV. SHOWER PAN w/ TILE SURROUND. PROVIDE TEMP. GLASS DOOR AND ENCLOSURE. CENTER OR CONCEALED FLOOR DRAIN PER BUILDER/OWNER SPECS. 29 TEMPERED GLASS SHOWER DOOR AND ENCLOSURE. A ro Lo 3 2 1 4'-6" 6-01/2" 1 1 2'- 0 1/2" 8' - 7 C D E F G 36'-6" 32' - 0" I . - O EXISTING PAVERSTONE PATIO TO BE LEFT IN PLACE.: '• '; KITC EN _. LESS 2' ALONG 2' - 0" FOUNDATION TO BE REMOVED . AND RESTORED 4'- 3" -POST NEW FOUNDATION,, WALL. 04 1ST FLOOR. 1/4" = 1'-0" 4'- 8 1/2" 1, 2'- 8 1/2" REMOVE CONNECTION TO EEr HOUSE AND TEMP. BRACE AT WALL UNTIL NEW FOUNDATION IS IN PLACE. - 10 1/2" 1, 12'- 0" 0' - 4 1/2 4' - 0" 2'- 8 1/2" 02 10 H O M -_ '1 CV N 2'-3" 3 I � I I I I I rnnnn 11-IHEAT PUMP lil HEAD (TYP) 06 BREAKFAST N OI11111111Ii luulnl Ilnnnl �uuuL HANDRAIL 3' - 7" ■ N BARN STYLE DOOR 07 I I I I I I I I I I I 1 19'-7" 5'-111/2" 4'-81/2" '-41/2"I 3'-2" U M __ ___ _ D-3 _M I 714CUBB0I7ES N(PER OWNER) coPANTRY Ln II III®uIIIIII I oH®IIIA uIIIIII INDIIIuIIIRIII I A1� III11I L N3 w (D U II1IIII1II I II1II I IIII I � M 11 III I ------------ D37 12'- 7" (V C.O. S.D. M TIMER D16 B TH CONTROLS 0 I 8 N � ENTRY 9'-91/2" 0 � I N DINING RMI D1, innnni - CV II II IIIIII N 20 20 o LI B R Y S.D. LunnnJ 60 I I I I I I al 4 - 08 5'-53/4" HANDRAIL 2'- 2 3/4" 1. 2'-6" D18 M O 3'-6" , 10'-0" 13'-6" 110 02 COVERED PORCH 3'-6" I 6 7 T-6" I I 5' - 5 3/4" I- 0 Lo 00 - 170 CFM WHOLE HOUSE FAN w/ TIMER (V.T.O.) 9' - 6 1/2" 10' - 0" 2'- 2 3/4" I, 7'-0" 13'- - 36" HIGH WALL w/ RAIL CAP AND TRIM PER BUILDER SPECS. U 11 o Lo CV 00 w V z N co 00 0) z QE Q � U IL Y= u1a�w w a 0 -J t J U Lo � 0) (o (6,2 z 00 LU im 00 aai LU m 0 LU n H E C Z N a0.. C L_ N' mng C U C w S O T fq N N ?: J' d E p Z J O U o COL ` a N@ N O N -2O- c� o a� U E w c° L) LL O U py"a2O L":zT y�aC!�E EL III Iac O WO QaaC° U�U -2 CU TC ONo° J J H C (0 .0 y 8 U O. 0 NL ° N T) 2 LUO m U a N '° E N U1 3 C H Z a 2" m d: o E° d RESUB Jul 25 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Uj m 06 o CV CD z co 01 J � W � H U Q z z O W :E Q z W H W LU W LULUU W Z ~ � W �a w LU wo z o Ln O zO 0 Q cv 0 0 .N 0 z PROJECT NO. 200302 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A6 PRINT DATE 2/20/2022 10:51:57 AM DOOR SCHEDULE - 2ND FLOOR SYM. NO. WIDTH HEIGHT DOOR TYPE COMMENTS 2ND FLOOR D20 2'- 6" 6-8" SINGLE PANEL D21 2'- 6" 6-8" SINGLE POCKET D22 2'- 6" 6-8" SINGLE PANEL D23 2'- 6" 6-8" SINGLE PANEL D24 5' - 0" 6' - 8" BI-PASS CLOSET DOOR D25 2'- 4" 6' - 8" SINGLE PANEL D26 2'- 8" 6-8" SINGLE PANEL D27 5' - 0" 6' - 8" BI-FOLD 4 PANEL CLOSET DOOR D28 2'- 6" 6-8" SINGLE PANEL D29 2'- 6" 6-8" SINGLE PANEL D30 4'- 8" 6' - 8" DOUBLE PANEL D31 2'- 4" 6-8" SINGLE PANEL D32 2'- 4" 6-8" SINGLE PANEL D33 2'- 4" 16-8" SINGLE PANEL D34 2' - 6" 16-8" SINGLE PANEL D35 5'- 0" 16'- 8" BI-FOLD 4 PANEL CLOSET DOOR WINDOW SCHEDULE - 2ND FLOOR SYM. NO. WIDTH HEIGHT AREA WINDOW TYPE U-VALUE COMMENTS 2ND FLOOR 12 9' - 0" 5' - 0" 45 SF DOUBLE SLIDER 0.28 13 2'- 9" 1' - 6" 4 SF PICTURE (FIXED) 0.28 OBSCURED GLASS 14 2'- 0" 3' - 0" 6 SF SINGLE HUNG 0.28 TEMP. GL. 15 5'- 0" 5'- 0" 25 SF PICTURE (FIXED) 0.28 TEMP. GL. 16 7' - 0" 4'- 0" 28 SF DOUBLE SLIDER 0.28 17 7' - 0" 4'- 0" 28 SF DOUBLE SLIDER 0.28 18 5'- 0" 5'- 0" 25 SF SLIDER 0.28 TEMP. GL. AND OBSC. GLASS 19 2'- 0" 3' - 0" 6 SF PICTURE (FIXED) 0.28 20 2'- 0" 3' - 0" 6 SF PICTURE (FIXED) 0.28 21 2'- 0" 3' - 0" 6 SF PICTURE (FIXED) 0.28 22 7' - 0" 4'- 0" 28 SF DOUBLE SLIDER 0.28 23 2'- 9" 1' - 6" 4 SF PICTURE (FIXED) 0.28 OBSCURED GLASS 24 2'- 9" 1' - 6" 4 SF PICTURE (FIXED) 0.28 OBSCURED GLASS 25 2'- 9" 1' - 6" 4 SF PICTURE (FIXED) 0.28 OBSCURED GLASS 28 4'- 0" 1' - 6" 6 SF SLIDER 0.28 Grand total 226 SF KEYNOTE SCHELDULE KEY VALUE TEXT 01 GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE OR 20 MIN. FIRE RATED RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING DEVICE. (R302.5.1) 02 LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 03 GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 & TABLE 302.6) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503) 06 GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) 07 STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6) 08 EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) 09 DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECS. AND IN STRICT ACCORDANCE W/ LOCAL BUILDING CODES. MUST BE U.L. LISTED. (M1303/ G2427.2.1) 10 DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 12 PILOTS, BURNERS, & SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. 17 CLOSET ROD w/ VINYL COATED WIRE SHELF 18 CLOSET SHELVING AND DRAWER ORGANIZERS PER BUILDER SPECS. TEMP. GLASS DOOR TEMP. GLASS WINDOW 19 20 22 ONE PIECE SHOWER WITH TEMP. GLASS SHOWER DOOR. 24 FIBERGLASS TUB w/ TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFICATIONS. 27 1/2" GWB UNDER STAIRWAY IN ENCLOSED SPACES. 28 HYDROBLOK OR EQUIV. SHOWER PAN w/ TILE SURROUND. PROVIDE TEMP. GLASS DOOR AND ENCLOSURE. CENTER OR CONCEALED FLOOR DRAIN PER BUILDER/OWNER SPECS. 29 TEMPERED GLASS SHOWER DOOR AND ENCLOSURE. A B C D E F G H I I I I I I I I I I I I I I I I 34' - 0" 2' - 0., 16- 5 1/2" 2' - 4 1/2" 13' -12„ 8'- 5 1/2" 6-8" 1 A2 6 — 'v I "' 18 FREE STANDING N TUB - WALK-IN SHOWER - SOAP SHELF -- I — rn 3 - -� 2 16'-0" ■I® 08 INSULATE INTERIOR WALL — 20 HEAT PUMP HEAD 17 (TYP.) I �flflfl�ll IIIIIIIIII (V PRIMARY SUITE II II III 19 �IIIIIIIII� � I I IIIIIIIIII IIIIIIIIII I IIIIIIII LUVUUJ 21 rt — 08 12' - O ao BEDROOM 4 co r DD. - N B TH S. 80 CFM 8'- 8 1/2" 7' - 3 1/2" 3' -10" D30 V.T.O. 4'-3" D3 20 ® I o WASH'R DRY'R ® o ® 18 I 80 CFM o LLA N D RY V.T.O,20 ° V0 P-BATH 28 0 2' - 6 1/2" 36" HALF WALL OR 29 06 RAIL PER BUILDER'I SPECS.) I i i i I I I I O O I I I I I I I \ D3 S.D. C.O. D31 I 07 I I I I I I I I 5 ------ Jj DN11 HANDRAIL 17 CFM W II C V.T.O. ART NICHE OR BOOKItASE ill ,I 4' 3" 7' -1 " 3' - 2 1 /2" 17 9'- 9 1/2" D23 D22 D 2 S.D. LINEN CLOSET S.D. 5'- 0" T - 5 1/2" 4' - 6 1 /2" n nII nII 17' it Ini IIIII o BEDROOM BATH '� D21 M 2 roll IIIIIIIIII D 0 IEDRO IIIIIIIIII IIIIIIIIII IIIIIIIIII �uuu IIIIIIIIII IIIIIIIIII LuLl D25 -- HEAT LAMP IN CEILING 08 24 ° 08 13T0" — 80 CFM O N M �r 0' ' V.T.O. L(j I 16 17 4'- - 11 1/2" 9'-6" I — 23 I 2'-41/2" � 13 25 I 1'-61/2", 1'-61/2" 24 I —r 3'-111/21, — 15'-0" 2'- 4 1/2" 4'- 11 1/2" 9'-6" 2ND FLOOR 1 /4" = 1'-0" 24 CO zl co 28 � - 2x6INSULATED WALL 10 - 14 (0 zo - 2x6 WALL M _M 11 V z N co O 00 z QE Q � U IL Y= u1aw a U J LO @ m CO � z 00N` LU im 00 aai LU m 0 LU n 2 H E U C + •N ^L^,, W c Z N B C L_ N C U C w E O T fq N N ?: ` N C o Z o o c O t m m N o aci n �- c� L o o a T g U E m c c° m: � p3ly ,r ci c c 5,� `ov 0-.2 TOLL 0 y� U°° T L `p N 0 C t6 .L' 2 N aw0aEyacaa"ia$y�a!�Oo O W M U O p.2 C U Q T F. °1C 3 C °° O J J H C (0 .0 y � O a 6 (6 N° N w O C° a N 'O E N U1 L 3 C � Z a o w m d m o E E° d RESUB Jul 25 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W Q m 06 C cV CD z 00 01 J � W � H U Q z z O W :E Q z 10 W H W LU W LULUU LU h Z W �a LU LU �o z o Ln O z : Q cu cu 0 c 0 .N 0 z PROJECT NO. 200302 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A7 PRINT DATE 3/7/2022 7:01:15 PM Im 2'-6" 2ND PLATE — — "L" FLASHING 7.3" SPRAYTITE OR EQUIV. CLOSED -CELL INSULATION (R-6.7 PER 1") MAIN PLATE B (: B B B 2'-0" 32'-0" I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I M-BATH W.I.C. LAUNDRYI I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I BREAKFAST NOOK MAIN FLOOR LOWER PLATE I z \ i14 as (2) LAYERS 8" TYPE "X" GWB AT \\\p ADU CEILIING w/ R-30 MIN. BATT INSULATI N (SOUND) (2) 2x4 TOP PL�TES.ST ERRUCTU L PLANS FOUNDATION AND FOOTING PER STRUCTURAL 2" GAP PLANS Y2" G.W.B. w/ APPROVED P.V.A. VAPOR RETARDER ADU LIVING RM.I 2x4 STUDS @1" O.C. (U.N.O. IN STRUCTURAL) R-21 BATT INSULATION (IN FULL WALL CAVITY) a P.T. 2x4 BASE LATE d a CAULKING/ SEALANT BEAD AT FLOOR PERIMETER ad 4" CONC. SLAB o/ 2" RIGID INSUL. o/ COMPACTE GRANULAR FILL CONCRETE SLAB LOWER FLOOR_ 4 ad a d d e _ GREAT FOOM I BEAM PER SCHEDULE HANGER FLOOR FRAMING PER SCHEDULE ADU DINING I I I I a Z 4 - I I I I a al I I I I I T BUILDING SECTION. A8) SCALE: .r -,-0 BUILT-UP TPO ROOFING o/ SHEATHING PER STRUCTURAL o/ BCI RAFTERS PER PLAN 3" SPRAYTITE OR EQUIV. CLOSED -CELL INSULATION (R-6.7 PER 1") A(R-21 BATT INSULATION IN FULL FLOOR CAVITY) SOLID BLOCKING SOFFIT PER ELEVATIONS 4"x "L" METAL FLASHING w/ DRIP EDGE INSTALLED UNDER BARRIER CONT. ALUM. GUTTER ON FASCIA BOARD PER ELEVATIONS (2) 2x6 TOP PLATES PER STRUCT. \STAGGER JOINTS A MIN. OF 48"O.C. FRAMING MEMBER ATTACHED TO TOP PLATES PER STRUCTURAL �' " G.W.B. CEILING BOARD %" G.W.B. w/ APPROVED P.V.A. VAPOR RETARDER EXTERIOR FINISH PER ELEVATION o/ 15# BUILDING PAPER OR APPROVED AIR INFILTRATION BARRIER o/ SHEATHING PER STRUCTURALPLANS 2x6 STUDS @16" O.C. (U.N.O. IN STRUCTURAL) R-21 BATT INSULATION (IN FULL WALL CAVITY) 3/4" T&G PLY OR EQUIV. SUB -FLOOR GLUED & NAILED TO FLOOR JOISTS PER STRUCTURAL CAULKING/ SEALANT BEAD AT FLOOR PERIMETER 2x6 BASE PLATE WAIST i'ER {JRPk — R-2 _BATT INSULATION AT RIM (2) 2x6 TOP PLATES PER STRUCT. _97= 701N7S_7V 11 .OF48 —_y2" G.W.B. CEILING BOARD 2" RIGID R-10 INSULATION INSTALLED IN CAVITY BETWEEN HEADER & INTERIOR G.W.B. \HEADER PER STRUCTURAL \Y2" G.W.B. w/ APPROVED P.V.A. VAPOR RETARDER WINDOW OPENING EXTERIOR FINISH PER ELEVATION o/ 15# BUILDING PAPER OR APPROVED AIR INFILTRATION BARRIER o/ SHEATHING PER STRUCTURALPLANS 2x6 STUDS @16" O.C. (U.N.O. IN STRUCTURAL) R-21 BATT INSULATION IN FULL WALL CAVITY I I NOTE: ALL DECKI MATERIAL SHALL CONFORM w/ I.R.C. & L CAL ODES. NAIL ALL DECKING OR SHEATF ING TO JOISTS w/ RING SHANKED F PT DIPPED GALV. NAILS. ALL RAILING AN I PAN EL SYSTEMS INSTALLED ER I C AND MFG. SPECS. TO MEET MIN. �0# P INT LOAD. ALL OPENINGS SHALL BE SRACE SUCH THAT A 4" SPHERE CANNOT P $S THROUGH. ( ) U 3/4" T&G PLY OR EQUIV. SUB -FLOOR o GLUED & NAILED TO o 0 FLOOR JOISTS PER STRUCTURAL t= h 2 � g CAULKING/ SEALANT BEAD LL AT FLOOR PERIMETER m 2x6 BASE PLATE RIM JOIST PER STRUCTURAL R-21 BATT INSULATION AT RIM — �(2) 2x_ TOP PLATES PER STRUCTURAL. \2" G.W.B. CEILING BOARD 2" G.W.B. w/ APPROVED P.V.A. VAPOR RETARDER EXTERIOR FINISH PER ELEVATION o/ 15# BUILDING PAPER OR APPROVED AIR INFILTRATION BARRIER o/ SHEATHING PER STRUCTURAL PLANS 2x6 STUDS @16" O.C. (U.N.O. IN STRUCTURAL) R-21 BATT INSULATION (IN FULL WALL CAVITY) 4" CONC. SLAB o/ 2" RIGID INSUL. w/ THERMAL BRAKE o/ COMPACTED GRANULAR FILL CAULKING/ SEALANT BEAD AT FLOOR PERIMETER P.T. 2x BASE PLATE w/ ANCHOR BOLTS PER STRUCTURAL PLANS 4" TIGHTLINE DRAIN WHERE REQ'D FOUNDATION WALL SIZE AND REINFORCING PER STRUCTURALPLANS 4" PERF. FT'G DRAIN. WRAP IN FILTER FABRIC w/ GRAVEL OVER FABRIC FOOTING SIZE AND REINFORCING PER STRUCTURAL PLANS J I JCOVERED PORCH I I I I \\2" SPRAYTITE OR EQUIV. CLOSED -CELL INSULATION (R-647 PER 1") R-21 BATT INSULATION I I I I I I GARAGE I I I I I I I I I I I I I I I I I I BATH ENTRY (1) LAYER $" TYPE "X" GWB d n a I I I I I I I I I I I I 2 BUILDING SECTION A8 SCALE: 1/2" = 1'-0" J z — N co 0 co a � U J W d u7 � N GS QWC O "� J � � U ��� coC° w z00C14` W V O m W m d W F— C O $ U . i C T'lIIIIII!iflllllllll(k no i Fr fi�l Z U E T F- O 'O U N o' a 2a p 0 W J w N y U N N °) d q 0° a o cycca°?d°-- ° .g Lij UJO o ° -20 d a W J Q H O RESUB Jul 25 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 N W z W Q z Q � O 0 a W W V) z � Q W o a Lo CL c O r a rn rra�h 0 Z PROJECT NO. 200302 TL DESIGNED BY DRAWN BY TL & RIM CHECKED BY TL SHEET: A8 PRINT DATE 2/20/2022 10:33 AM 2 - CARPET o/ PADDING OR HARDWOOD - 3/4" T&G PLY SUBFLOOR GLUED AND NAILED TO TRUSSES - R-30 BATT INSULATION (2) LAYERS 5/8" TYPE X (SEE BELOW) 1 HOUR CEILING ASSEMBLY WITH MANUF. I -JOISTS GA FILE NO. FC 5407 IIC 50 Base layer 5/8" type X gypsum wallboard applied at right angles to wood I -joists w/ 1 1/4" Type W or S drywall screws 24' o.c. Face layer 5/8" type X gypsum wallboard applied at right angles to trusses with 1 7/8" Type W or S drywall screws 12" o.c. at joints and intermediate trusses and 1 1/2" Type G drywall screws 12" o.c. placed 2" back on either side of end joints. Joints offset 24" from base layer joints. Wood I -joists supporting 1/2" wood structural panels applied at right angles to trusses with 8d nails. Ceiling provides 1 hour fire resistance protection for I- j0lsts. 1 HR CEILING ASSEMBLY 3/4" = 1'-0" NOTE: SOME STRUCTURAL COMPONENTS NOT SHOW FOR CLARITY. SEE STRUCTURAL DETAILS. - - PRESSURE TREATED MUD SILL PER STRUCTURAL PLANS WRAP R-21 BATTS AT PERIMETE OF FLOOR CAVITY. (2) LAYERS 5/8 GWB PER RATED DETAIL AT A.D.U. CELINGS. a - p- d ° DBL. 2x4 TOP PLATES 8 Q•. , 1/2" G.W.B. R-VALUE j0o �o �o BATT INSULATION: R-21 TOTAL WALL R-VALUE: R-21 3/4" T&G PLY SUB -FLOOR �— I -JOIST PER PLAN 5/8" TYPE "X" GWB AT CEILING WHERE INDICATED. EXHAUST FAN - LINE JOIST BAY WITH (1) LAYER 5/8" TYPE "X" GWB AT SIDES AND (2) LAYERS AT UNDERSIDE OF FLOOR FOR EXHAUST HOUSING. HOUSING 3/4" T&G PLY SUB -FLOOR �- (2) LAYERS 5/8" TYPE "X" GWB AT CEILING WHERE INDICATED. LINE JOIST BAY WITH (1) LAYER 5/8" TYPE "X" GWB OR TENT OUT SMALLER SECTION AS NEEDED WITH ADDDITION JOIST OR FRAMING. DUCTWORK IN JOIST BAY CEILING PENETRATIONS 1" = 1'-0" 3/4" T&G PLY SUB -FLOOR I -JOIST PER PLAN WALL PLATE SOFFIT FRAME 5/8" TYPE "X" GWB PER BUILDER AT CEILING WHERE INDICATED. DUCTING 1/2" GWB ITION WALL GA WP3644 DROPPED SOFFIT AT DUCTWORK PERPENDICULAR TO JOISTS 3/4" T&G PLY SUB -FLOOR I -JOIST PER PLAN 5/8" TYPE "X" GWB AT CEILING WHERE INDICATED. LINE JOIST BAY WITH (1) LAYER 5/8" TYPE "X" GWB AT SIDES AND (2) LAYERS AT UNDERSIDE OF FLOOR FOR EXHAUST HOUSING. RECESSED CAN LIGHTING ° 2x4 STUD WALL w/ STUDS @ 16" One layer 5/8" type x GWB applied GRANULAR, FREE -DRAINING ?�o �o �o �o � ; ° O.C. AND OFFSET 2" FROM CONCRETE at right angles to each side of 2x4 (2x6) wood studs 16" 2 1/4" Type S W drywall MATERIAL WITHIN 12" OF X X� ° d WALL. @ o.c. with or screws WALL AND WITHIN 12" - 12" o.c. 3 1/2" mineral fiber insulation, nominal 2.5pcf, OF FINISHED GRADE. ���J�O� R-21 FIBERGLASS BATT friction fit between studs. Vertical joints staggered 16" o.c. ,. INSULATION horizontal joints staggered 24" o.c. on opposite sides. - DAMPROOFING FOUNDATION WALL AND FOOTING PER STRUCTURAL MIRIDRAIN OR EQUIV. >�oOXoO�oO�o -" PLANS. WALL DRAIN BOARD SYSTEM O000O000O000Oo � _ -- - PRESSURE TREATED 2x4 PLATE a Z)���� - �C CD5 C � - - 4" CONCRETE SLAB 4" PERFORATED FOOTING ��O�O�Oo 4- • DRAIN (OR PER CITY STD'S) 00000 "' - d . a PLATE wF 1//2" ANCHOR a a , - BOLTS INTO EXISTING a a a d Ix xx CONCRETE @ 48' O.C. AND WITHIN 12" OF ENDS. ° ° d P a ° oOoOo a' a •• ,°a• • < •" 2" SAND ON COMPACTED GRANULAR FILL 2" RIGID INSULATION UNDER _ ENTIRE BASEMENT SLAB = (TYP. @ ALL HEATED SPACES) - THERMAL BREAK. BASEMENT WALL INSULATION 111 = 1'-0" 1 HOUR INTERIOR WALL 3/4" = 1'-0" - OPTION: PRE-MANUF. RATED CAN OR TENT. V Z N co O 00 W Z Q E Q � U IL Y= rn wa'w w ,n aa1 0 "�� U ��@ M(O.O Z ooN` LU _ N 0 N LU M 0 LU n H E U C N s O T fq N N ?+ J y d E Z5 o Z o o c O c� a m c .� := o ��Qa 013rnn'v,r ci�c��o�a"ior. O l V y` U E N a O W a E V N (q O a d O C N N O U O w 2 U° 8 w o V O a��i w U J JH Cm'.'w Z5 0.=mO woo w O M O a N 'O E N U1 aa L O C Zaod: OHE°5 RESUB Jul 25 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W Q Im 06 o c14 CD Z 00 01 J � W � H V Q Z Z 0 W :E Zu, H W LU W W LU H wU Z W �a LU LU w �o z o ,n O OZ o0 Q 0 c 0 .N 0 z PROJECT NO. 200302 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 2/20/2022 10:24:18 AM GENERAL NOTES WOOD All design and construction shall conform to the requirements of the 2018 International Building Code. SAWN LUMBER: Structural sawn lumber shall be kiln dried and be of the species and grade noted below or better: SHEAR WALL PER PLAN Contractor shall verify all levels, dimensions and existing conditions in field before proceeding with any Use Grade Fb(psi) 24" construction or demolition. Contractor shall notify the Architect of any discrepancies or field changes Wall Studs Hem Fir Stud 675 SOLE PLATE NAIL/SCREW Plates & Planks Hem Fir #2 850 PT SILL PLATE w/ ANCHOR BOLTS SHEAR WALL PER PLAN Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or Joists & Rafters Hem Fir #2 850 EDGE NAILING AND WASHERS PER SHEAR WALL #4 x 24" MATCH HORIZ procedures required to perform the work. Contractor shall provide adequate shoring and bracing of all 4x Beams Douglas Fir -Larch #2 900 SCHEDULE. MINIMUM ANCHOR TYP. WALL REINF. structural members, existing construction and soil excavations as required, in a manner suitable to the work 6x Beams Douglas Fir -Larch #2 875 = BOLT EMBEDMENT 7. REINF. TYP. 24 sequence. Temporary shoring and bracing shall not be removed until all final connections have been Posts Douglas Fir -Larch #2 750 PT SILL PLATE w/ ANCHOR BOLTS completed in accordance with the drawings and materials have achieved design strength. Foundations walls 2x4 T&G Decking Douglas Fir -Larch Select 1750 FLOOR BOUNDARY NAILING AND WASHERS PER SHEAR WALL #4 x 24" greater than 4 feet shall not be backfilled until the floor framing and all connections to the floor framing per SCHEDULE. MINIMUM ANCHOR MATCH HORIZ these details are complete. All lumber and plywood exposed to weather or water or in contact with concrete stucco masonry P PY P Y 2x RIM JOIST BOLT EMBEDMENT = 7". REINF. or other cementitious materials shall be treated with an E.P.A. acceptable wood preservative, such SHEAR WALL SHEAR CLIPS, CHANGES: No changes to these structural drawings are permitted without written consent of the Engineer. as Alkaline -Copper -Quaternary "ACQ" or Copper Azole "CBA" type A and B. OR ALTERNATE PER 18/S8 Changes will be billed to the client, owner or contractor at the Engineer's hourly rate. - All wood connectors shall be manufactured by Simpson Strong Tie Company (or approved equal), SUBMITTALS: Shop drawings shall be submitted to the Architect prior to any fabrication or construction for and of the size and type shown on the drawings. All wood connectors in contact with/\// \\//\ ��/j #4 HORIZ. AT 18" o.c. AND (2) AT 8" THICK WALL \ TOP OF WALL all the following: preservative -treated wood shall be Triple Zinc G-185 galvanized (1.85 oz/sq ft coating). #4 HORIZ. AT 18" o.c. AND (2) AT 8" THICK WALL ��\ UNLESS NOTED ALT. HOOK Structural steel, steel canopies, glued -laminated members and pre -manufactured wood TOP OF WALL UNLESS NOTED OTHERWISE members. MINIMUM WOOD NAILING REQUIREMENTS: Unless otherwise noted on the drawings, typical wood OTHERWISE #4 VERT. DOWELS AT 24" o.c. SINGLE REINFORCING #4 x 24" framing shall be fastened as follows. See IBC Table 2304.10.1 for fastener alternatives not shown. #4 VERT. DOWELS AT 24" o.c. x z ALTERNATE HOOK AT BASE a - MATCH HORIZ Design drawings and calculations, for pre -manufactured wood trusses and joists shall bear the seal and Location Min. Nail Quantity/Spacing Type* a z ALTERNATE HOOK AT BASE REINF. signature of the Washington State Registered Professional Engineer who is responsible for the design, and Beams (built up 2x's) 3" x 0.131" 24" o.c. T&B* FN 00 PERF. FTG. FOOTING PER PLAN shall be submitted to the Architect and Building official for review prior to fabrication. EF* staggered - a ,1D„ PERF. FTG. FOOTING PER PLAN DRAIN NOTES: Blocking -to joists, rafters, trusses 3" x 0.131" 2 each end TN DRAIN 1. VERTICAL REINFORCING NOT DESIGN LOADS or studs SHOWN FOR CLARITY LIVE LOADS: Live loads are determined in accordance with ASCE Ch. 7 -to top plates 3" x 0.131" 3 TN m " - - 2. SEE STRUCTURAL NOTES FOR L = 40 PSF (Residential) Bottom plate -to joist, rim joist 3" x 0.131" 12" o.c. FN m _ CLEAR COVER DOUBLE REINFORCING = 60 PSF (Balcony) or blocking SNOW LOADS: Snow loads are determined in accordance with ASCE Ch. 7 with the following -to studs 3" x 0.3 EN Factors: Header (built up 2x's) 16d boxx 12" o.c. T&B FN Ground Snow Load Pg = 20 psf Ct = 1.0 Ce = 1.0 Header -to studs 3" x 0.131" 4 TN Joist -to supports 3" x 0.131" 3 TN TYPICAL CONCRETE FOUNDATION 1 2 TYPICAL CONCRETE WALL AND FOOTING CORNER 3 Roof Snow Load Ps = 25 psf Is = 1.0 WIND LOADS: Wind loads are based on ASCE 7-10 Ch. 28 (Envelope Procedure) with the following factors: -to rim joist 3 x 0.131" 4 EN Exposure Category = B Iw - 1.0 Rafter -to supports 3" x 0.131" 4 TN, EN Velocity (3 sec) =110 mph (ult) Kzt - 1.0 Rim Joist -to sill or blocking 3" x 0.131" 6" o.c. TN A35 EACH BLOCK BOTH SIDES Design wind pressured for determining forces on components and cladding are determined in Stud -to Stud 3" x 0.131" 12" o.c. FN STAGGERED -to top/bottom plate 3" x 0.131" 4 TN accordance with ASCE 7-10 Chapter 30. FLOOR BOUNDARY NAILING SHEAR WALL PER PLAN 10d AT 4" o.c. TO BLOCKING SEISMIC LOADS: Seismic loads are based on the Equivalent Lateral Force Procedure in ASCE 7-10 Section Top plate -to top plate 3" x 0.131" 12" o.c. FN SHEAR WALL PER PLAN . 12.8 with the following factors: -to studs 3" x 0131" 3 EN SOLE PLATE NAILING FLOOR JOISTS PER PLAN Risk Category = II Ss = 1.27 -laps at corners and 3" x 0.131" 3 FN SOLE PLATE NAILIING EXTEND BLOCKING Site Class = D S1 = 0.499 intersections A35 EACH JOIST BOTH SIDES AND NAILING TO 3RD POST PER PLAN Design Category = D SDS = 0.849 Truss to top plate 3" x 0.131" 4 TN EDGE NAILING STAGGERED EDGE NAILING BAY AT 32" o.c. R = 6.5 (wood shear wall) SD1 = 0.599 Ie = 1.0 Cs = 0.131 (ult.) *EN =end nail, FN =face nail, TN =toe nail, EF = "each face", T&B = "top and bottom" HORIZONTAL EARTH LOADS: Horizontal soil loads used for design of retaining walls and basement walls FLOOR BOUNDARY POST BASE PER RATED SHEATHING: Wood structural panels shall bear the APA trademark of the American Plywood are based on assumed soil values typical of this region: CONT. 2x RIM JOIST NAILING SCHEDULE Association. Sheathing shall be as follows: Active Pressure (Restrained) -55 pcf (EFP) Shear Wall Shtg APA rated 7/16" 32/16 C-D INT with Exterior Glue (CDX or OSB) Active Pressure (Unrestrained) -35 pcf (EFP) 12" SONO TUBE FORM Roof Shtg APA rated 15/32" 32/16 C-D INT with Exterior Glue (CDX or OSB) Passive Pressure -250 pcf (EFP) SHEAR WALL SHEAR CLIPS °% Sub Floor Shtg APA rated 3/4" 48/24 T&G C-D INT with Exterior Glue Coefficient of friction -0.4 g OR ALTERNATE PER 18/S8 CONT. 2x RIM JOIST (3) #4 VERT. Sheathing shall be orientated over the supports as shown on the drawings. Shear wall sheathing DOWELS shall be blocked at all panel edges as shown in the shear wall schedule. FOUNDATIONS SHEAR WALL SHEAR CLIPS BAYS OF 2x BLOCKING Concrete foundations shall be on Bearing Ground defined as follows. Bearing Ground shall be stiff, GLUED LAMINATED MEMBERS: Glued Laminated members shall each bear an AITC identification • OR ALTERNATE PER 18/S8 • (1) DOUBLE PRESSURE TREATED • AT 16" o.c. placed 2x8 SILL PLATE NAILED WITH �/ ,,, �// /� FOOTING PER \ competent, non -expansive, undisturbed native soil. Where native soil is inadequate for bearing, foundations mark and be accompanied by an AITC certificate of conformance. One coat of end sealer shall be (2) ROWS 10d AT 6" o.c. DOUBLE PRESSURE TREATED �\ PLAN shall be placed on structural fill mixed and compacted in accordance with specifications provided by a applied immediately after trimming either shop or field. Members shall be Visual Graded Western 2x8 SILL PLATE NAILED WITH o LL Washington State licensed Geotechnical Engineer. Prior to construction, the contractor shall verify the Species Inductrual, Architectural or Premium grade with strength as follows: (2) ROWS 10d AT 6" o.c. z w Bearing Ground has minimum allowable bearing pressure = 2000 psf. Plan Symbol Common Name Species Fb E GLULAM Glulam DF 24F-V4 DF/DF 2400/1850 psi 1,800,000 psi / ANCHOR BOLTS AT 16" 5/"� ANCHOR BOLTS AT 16" 00 Bottom of footing elevation shall be located at minimum frost depth 18" below top of finished grade unless GLULAM V8 Glulam DF 24F-V8 DF/DF 2400/2400 psi 1,800,000 psi o.c. UNLESS TIGHTER SPACING o.c. UNLESS TIGHTER SPACING required otherwise by the Building Official. The contractor shall confirm the minimum frost depth with the IS REQUIRED PER SHEAR WALL 1-1/2" CLR. IS REQUIRED PER SHEAR WALL 1-1/2" CLR. Building Official prior to excavation. ENGINEERED COMPOSITE LUMBER: Engineered Composite Lumber shall be manufactured by SCHED. FROM INSIDE FACE SCHED. FROM INSIDE FACE Trus-Joist, Boise Cascade or approved equal and shall have the following minimum strength (based EMBED = 7" MIN (+1/4", -0") EMBED = 7" MIN CONCRETE on 12" member depth): Concrete work shall comply, in general, with ACI 301 (latest edition) "Specifications for Structural Concrete Symbol Common Name Manufacturer Fb E for Buildings." PSL Parallam Trussjoist 2900 psi 2,000,000 psi LVL Micolam Trussjoist 2600 psi 2,000,000 psi 8" THICK CONCRETE WALL REINF. 8" THICK CONCRETE WALL REINF. AND WITH #5 VERT AT 12" TYPICAL EXTERIOR ERIOR ISOLATED FOOTING 6 psi 000 300p psi 1,, CONCRETE MIXES: Concrete mixes shall conform ACI 318 Ch. 5. Minimum concrete strength fc at 28 days LSL Timberstrand Trussjoist 1700 p . .. o c WITH #5 VERT. AT 12" o.c. AND #4 HORIZ. AT 18" o.c. AND (2) AT shall be as follows: VL (1%4-2%$") Versa Lam Boise Cascade 2800 psi 2,000,000 psi #4 HORIZ. AT 18" o.c. AND (2) AT Slab -on -grade, Curbs and Pads - 2000 psi VL (3%" & wider) Versa Lam Boise Cascade 3100 psi 2,000,000 psi TOP. TOP. Footings - 2500 psi PREMANUFACTURED OPEN WEB WOOD TRUSSES: Trusses shall be design by a Structural Engineer Walls, Stems - 3000 psi (2500 psi used for structural design) licensed in the State of Washington, who is regularly engaged in the design of plate -connected DRAINAGE BOARD OR DRAINAGE BOARD OR 12" THICK LAYER OF 12" THICK LAYER OF 1/4 Water/cement ratio shall be measured by weight and shall be based on the total cementitious material. wood trusses. Truss design shall be accordance with IBC Section 2303.4. FREE -DRAINING GRAVEL FREE -DRAINING GRAVEL Water/cement ratio shall be determined b the supplier based on strength requirements and shall not exceed y pp g q FULL HEIGHT OF WALL FULL HEIGHT OF WALL #4 DOWEL AT 18" o.c. CENTERED STEELPC COLUMN o 0 m >- 0.55. Water-reducingadmixtures may be incorporated in concrete mix designs but shall conform to ASTM C Trusses shall be design for the following superimposed dead loads: Y P 9 ALTERNATE HOOK AT BASE 464, and be used in accordance with the manufacturer's recommendations. CaCI and other water-soluable top chord bottom chord totalV #4 DOWEL AT 18" o.c. CENTERED I I chloride admixtures shall not be used. roof trusses 10 psf 5 psf 15 psf . SLAB ON GRADE PER PLAN • ALTERNATE HOOK AT BASE I I %4" BASE PLATE 0 0 REINFORCING STEEL: All reinforcing shall be deformed bar (rebar) with bar diameters specified in these In addition to dead loads, the design shall include the live, wind, snow loads as identified in the W/ (4) 0 1 1/2" NON -SHRINK drawings and properties below: "Design Loads" section of these drawings, and the snow drift, sliding and unbalanced loads per SLAB ON GRADE PER PLAN WEDGE ANCHORS. LEVELING GROUT PER S1 TYP EMBED 4" MIN All reinforcing unless noted otherwise - ASTM A615, Grade 60 ASCE7 Chapter 7. The truss design shall include concentrated and axial loads shown on framing o o STRUCTURAL NOTES I I #3 stirrups and ties - ASTM A615, Grade 40 plans and hanger schedules in these drawings. N N Welded rebar - ASTM A706, Grade 60 SLAB ON GRADE SONO TUBE ISOLATION Galvanized Welded Wire Fabric - ASTM A165 Roof trusses shall be designed for wind net uplift of 10 psf unless otherwise noted on the drawings. PER PLAN JOINT. DRY PACK AFTER I I COLUMN IS IN PLACE Reinforcing steel shall be detailed in accordance with ACI 315 Manual of Standard Practice for Detailing Trusses shall be fabricated by a manufacturer who is a member of the Truss Plate Institute. Trusses Reinforced Concrete Structures. shall be supplied with the proper hangers, end connections, bridging, bracing to provide lateral I stability of all truss members, and tie -down connections to beams and tops of walls. Trusses shall chord bears on the full width of ever so that ever tapered hardwood shimming with tapg y y Reinforcing steel shall be lapped as noted on the drawings. Where lap length is not shown, reinforcing bars be suppliedPERF. FTG. DRAIN IN PERF. FTG. DRAIN IN I I shall be lapped as follows: support, without notching the truss members. The truss manufacturer is responsible for ensuring 12" GRAVEL 12" GRAVEL 00 #5 and smaller - 48 bar diameters the bearing seat does not exceed the sill plate capacity of the supporting element. _ _ • #6 and larger - 60 bar diameters PREMANUFACTURED WOOD I -JOIST: Shall be fabricated by Truss -Joist or Boise Cascade. Minimum concrete cover over reinforcing shall be as follows: Alternative manufactures must be approved by the Architect or Engineer. Joists shall be in m u FOOTING PER PLAN Nonstructural Slab -on -grade - Mid -Depth according to the manufactures instructions including blocking, web stiffeners, bridging, etc. Fasten JOISTS PERPENDICULAR TO WALL JOISTS PARALLEL TO WALL Wall Bars: interior face - 3/4" joists to supports as recommended by the joist and hanger manufacturer. Provide temporary • exposed to earth/weather - 1-1/2" (#5 and smaller) bracing as recommended by the manufacturer to hold joists in place until permanently secured, Cut 2" (#6 and larger) openings in joist webs only as allowed by the manufacturer. Footings: Bottom Bars - 3" (cast against earth) M Top Bars - 1-1/2" RECOMMENDED INSPECTIONS Side Bars - 2" The following recommended minimum items shall be inspected by a qualified individual provided by the Building Official: - FULL HEIGHT CONCRETE BASEMENT WALLS BRACED 8 SECTION 9-Footings Provide supports as required for proper alignment and concrete cover around the reinforcement. Consult the bear on competent native soil per the "Foundations" section above CRSI Manual of Standard Practice MSP-1 for specific information. -Footing reinforcement -Shear wall sill plate anchors and washers per schedule STRUCTURAL STEEL -Shear wall nailing and shear clips per schedule STEEL MATERIALS -Shear wall hold-downs Structural Steel Grade 50, ASTM A-992, ASTM A-572 -Verify type, size and grade of structural steel members and bolts Connection material, embedded items, ASTM A-36 channels, angles, plates, misc. Structural Tubes ASTM A-500, Grade B Structural Bolts ASTM A-325-N, A-325-SC, A-490-N, A490-C Threaded Anchor Rods ASTM F-1554, Grade 55 POST PER PLAN BEARING WALL PER PLAN Welding Electrodes 70 KSI Low Hydrogen PRESSURE TREATED SILL PLATE FABRICATION AND ERECTION shall conform to the requirements of the IBC chapter 22. All members are to EDGE NAILING PER WITH %Z" DIA. ANCHOR BOLTS AT 48 be erected with natural camper upward. Substitution of member sizes or steel grade will not be allowed SILL PLATE PER 11/S1 SHEARWALL SCHED o.c. TO SILL PLATE without prior approval of the Architect. All bolted connections are to be ASTM A-325 or A-490 unless otherwise noted. The Contractor shall be responsible for all erection aids and joint preparations that include, SLAB -ON -GRADE SLAB -ON -GRADE but not limited to, erections angles, lift holes and other aids, welding procedures, required root openings, ADD (2) #4 x48" EACH WAY PER PLAN #4 x48" AT 24" o.c. AT PER PLAN root face dimensions, groove angles, backing bars, copes, surface roughness values and unequal parts. TYPICAL DETAILS AT MID -DEPTH OF SLAB MID -DEPTH OF SLAB WELDING: All welding shall be in conformance with AISC and AWS Standards, and shall be performed by In addition to the details and schedules on the framing plans, those noted as "Typical" shall be AWS-WABO certivied welders using 70 KSI electrodes and low hydrogen processes. Only welds that are used throughout the structure as applicable. prequalified, as defined by AWS, or qualified testing shall be used. Shop drawings shall show all welding with AWS A2.4 symbols. Welds shown on the drawings are minimum sized based on plate thickness. Minimum weld size shall be 3/16 inch, unless noted otherwise. The welds shown are for the final connections. Field weld symbols are shown where the field weld is required by the structural design. Where field weld is not • indicated, the Contractor is responsible for determining if a weld should be shop- or field -welded in order to facilitate the structural steel erection. _ C� THICKENED SLAB _ THICKENED SLAB BASE PLATE GROUT: u FOOTING PER PLAN `" v FOOTING PER PLAN Base plate grout shall be nonshrink type with minimum f'c = 8000 psi. STRUCTURAL NOTES THICKENED SLAB FOOTING AT POST 10 THICKENED SLAB FOOTING AT BREARING WALL 11 SECTION 12 Ross Engineering Design Inc ryan.ross@rossengineer.com ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN RESUB Jul 25 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 CV UJ 00 o� Q Z W z 0 W O � J LU LU a W w co W Z_ Q W 12 Z aLo CL m 0 0 N m 0 6 z FILE/ NO. 20044 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S1 PRINT DATE 10 / 29 / 2021 .0� Al T_ I; SW3P MAIN FLOOR SHEARWALLS SCALE: 1/8" = V-0" SW5 `i ------------------------ LJ 51 BASEMENT FLOOR SHEARWALLS SCALE: 1/8" = 1'-0" EXTERIOR WALLS NOT MARKED SHALL BE SW1 HOLDDOWNS CALLED OUT ARE LOCATED AT BASE OF SHEAR WALLS. SEE SHEET 5/S7 FOR HDU ANCHOR SCHEDULE AND 5/S8 FOR SHEAR WALL SCHEDULE 2ND FLOOR SHEARWALLS SCALE: 1/8" = 1'-0" J z - N co 0 co a � U J W d u7 ,� N GS QWC O _j J 7 U 20)@) co CO w z 00NLU ` N — 0 m W m d W F- E O V . i C L o m o 0 Z U E U1 .N —° a) 01 C@ U T O 'O U N b o L @ ), a y C 0 o Z 0 N U O S' m R CO N U O Q Z C — ���UE y p Um y:; Eyoy=` o o) ` O N° O o UJ0 o °0:..0 a, oo-p..q w !=n a. " a s@� o w N o z d m> E m m J Q H O 10/29 2021 ypN N. RoS � pE WAS,yiy S �n Z 21 44 46411 6ISTER�� SS�ONAL ECG ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN RESUE o W Jul 25 2022 Q CITY OF EDMONDS 00 SERVICES DEPARTMENT UDEVELOPMENT < z W Q z 0 � O _ (n a o W F LU pC °d LU C� z Q W o Z a Lr) CL 0 �L 0 Z PROJECT NO. 200302 TL DESIGNED BY DRAWN BY TL & RM CHECKED BY TL SHEET: S2 PRINT DATE 10/29/2021 9:51 AM FOUNDATION NOTES • VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO COMMENCING ANY WORK. • GENERAL CONTRACTOR AND/OR FOUNDATION CONTRACTOR SHALL VERIFY THE LOCATION OF ANCHOR BOLTS AND HOLDOWNS PRIOR TO POURING CONCRETE. • ALL FOOTING SHALL BEAR 18" BELOW UNDISTURBED NATURAL SOIL. FINISHED GRADE SHALL BE NO LESS THAN 12" ABOVE BOTTOM OF FOOTINGS. • TOP OF FOOTING SHALL BE LEVEL. BOTTOM SURFACE OF FOOTING SHALL NOT SLOPE MORE THAN 10%. STEP FOOTING AS NECESSARY TO MAINTAIN MIN. DEPTH OF FOOTING BELOW FINISHED GRADE. • FOUNDATION WALL SHALL EXTEND MINIMUM 6" ABOVE FINISHED GRADE. • ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. • UNLESS NOTED OTHERWISE OR IN SHEAR WALL SCHEDULE, ALL ANCHOR BOLTS SHALL BE %2' dia. x 10" AND EXTEND MINIMUM 7" INTO CONCRETE WITH MINIMUM SPACING OF 48" ON CENTER. EACH ANCHOR BOLT SHALL HAVE A 3"x3"x.229" GALVANIZED WASHER. • SEE SHEARWALL & HOLDOWN SCHEDULES FOR SIZE AND PLACEMENT. • CRAWLSPACE ACCESS SHALL BE A MIN. OF 18"x24". OPENINGS THROUGH A PERIMETER WALL SHALL BE NOT LESS THAN 16"x24". (R408.4) • PROVIDE A 6 MIL. BLACK VAPOR BARRIER OVER ALL CRAWLSPACE AREAS. (R406.3.2) • PROVIDE 2" SAND OVER 6 MIL BLACK VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL UNDER ALL CONCRETE SLABS. • PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS ARE IN PLACE. • ALL ISOLATED SPREAD FOOTING TO BE 24"x24"x8" REINFORCE FOOTINGS WITH (2) #4 BARS EACH WAY UNLESS NOTED OTHERWISE IN PLAN. • FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM TOP OF FOOTING TO FINISHED GRADE. (R406.1) • SEE SIMPSON RECOMMENDATIONS FOR HOLD DOWN PLACEMENT. COORDINATE LOCATIONS WITH DOOR & WINDOW ROUGH FRAMING TO PROVIDE ACCURATE DIMENSION FOR OPENINGS. FOUNDATION VENT CALCS. (R408.1) PROVIDE 1 SQ. FT. OF VENTILATION FOR EVERY 300 SQ. FT. OF CRAWLSPACE. FOUNDATION VENTS SHALL BE EXTRUDED, LOAD BEARING 16"x8" VENTS. PROVIDE A MINIMUM OF (1) FOUNDATION VENT WITHIN T-0", BUT NOT WITHIN THE FIRST 1'-0" OF EACH CORNER OF CRAWLSPACE. ASSUMED VENTS ARE MIN. 15.5"x6" AND HAVE A NET FREE VENTILATION AREA OF .48 SQ. FT. FOUNDATION VENT CALCULATIONS CRAWLSPACE AREA 78 SQ NET VENTILATION AREA/ 300 SQ FT 0.26 NET AREA NUMBER OF VENTS REQ'D NETAREA/ 0.48 1 OPTIONAL POWER VENT CRAWLSPACE HEIGHT 3 15.6 C A B C D E F G H LTISTING CONCRETE LANDING I I I I I I I I I I I I I I I I 6'-0" 8 - ------ --- - - - 1 ,8 — -- ---- - - - - - -rt- - - - --j--- —------------ ——j---------r— — ------ - -I - - - - - - - I I I I I H I I I 7 — — — — — — — — — —I — — — — — — — — — — :---------- I. L' j F F-01 F-01 I I Iw I I I TYP. 8" CONCRETE STEM WALL ON 16'W" CONCRETE FOOTING (TYP. U.N.O.) CONCRETE LANDING & STEPS TO GRADE PER I.R.C. 4' 4%a" - - 8 10 BASEMENT SLAB L3 S1-05 S1 / 4 CONC. SLAB. S1 �- 11' 3%4' T 9%a \ 4' 3" 2'-8" 6' 0" o/ 2" RIGID INSULATION j FoO�(i8 F-01 coF-02 —Y��Cy NOTE ! 6----— - — - — -—----- - - - - -- 41 co CONTRACTOR TO VERIFY ALL DIMENSIONS 00 - - NOTE! ALL FOUNDATION WALLS $1 F — — 0 J TO BE 8" UNLESS CALLED OUT LOTHERWISE. --rt-- tio I I I I I I 4 LEGEND M I I I I I I `� 0 STEM WALL WALLS/ FIXTURES OVER — j — FOOTING CONCRETE SLAB 5 L,—,-- — — ------- EXISTING 4II/�V)t_ L_04--DOOR OPENING - 3 - - �-------j----------------------- - --- - - - NO BOLTS - - f- a o r- ( ) CONCRETE FOOTING SCHEDULE I I I I CVO I I I 2'-6" 0" I SYM. FOOTING SIZE PLACEMENT F-Ol *16"x8" CON'T. (2) #4 CON'T. F-02 16"x8" CON'T. (2) #4 CON'T. F-03 *24"x24'W" (2) #4 EA. WY. GARAGE SLAB F-04 *36"x36'W" (4)#4 EA. WY. 8 1 4" CONC. SLAB. SLOPE MIN. 8' F-05 48"x48"x8" $ (5) #4 EA. WY. PER V-0" TOWARDS GARAGE DOORS. 11'-3'/a" °' �, F-06 '48"x48"x8" (5) #4 EA. WY. F-07 *16"x12" CON'T. (2) #5 CON'T. j F-01 j TOP AND BOTTOM 3 J 1 I L 1- i— �- -I L rBEAR XTERIOR FOOTINGS SHALL BE MIN. NOTE: BELOW GRADE AND REST ON F-04 ING SOIL. 2 -- ---4I -- - - - I - - - I - -- —�Ll F' REMOVE EXISTING CONCRETE CONCRE E L kND NG & ST P WALL ALONG GRID "G" ` " TO R I. .C.R_ ----- P v F— - F-07 I I I I I I CC-4tol/l co v - • .., ,•a- I I I CV� I I I CONCRETE LANPINg & TO GRADE PER I.R 64' 1-1 '-C" 1- 8'-3" 1- 2'-9" L � 16'-3" 1- 2'-4% FOUNDATION PLAN SCALE: 1/4" = 1'-0" 10/29 2021 y p,N N. /?o pE WASyiN S 21 44 46411 SSGISTER� 0NM_ ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN W 0 CD RESUB co Jul 25 2022 Q z CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ui vi o 7- 0 LU Q LU W W Z Q W o z Q Lo CL c 0 a °L w m O Z PROJECT NO. DESIGNED BY 200302 TL DRAWN BY TL & RM CHECKED BY TL SHEET: S3 PRINT DATE 10/29/2021 9111 AM POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P-01 (1) 2x_ STUD w/ (1) TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-02 2x_ STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-03 (2) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-04 (3) 2x_ TRIMMERS (4) 16d NAIL (HEADER) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. A B C D E F G H P-05 (3) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-06 (4) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-07 6x8 DF#2 (4) 16d NAIL (DBL. TOP PLATE) (6) 16d NAIL (TOE PLATE) P-08 6x6 DF#2 14/S7 (6) 16d NAIL (SUB FLR/BLKG) P-09 HSS4x4x1/4 SEE 9/S7 SEE 9/S1 P-10 44 PT HF#2 EPC4Z ABU44Z w/ %"x5" TITEN HD P-11 44 PT HF#2 CC44 OR ECC44 (2) A35 w/ #9x2.5" SCREWS NOTE: SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE BEAM SCHEDULE SYM. BEAM BM-01 48 DF#2 OR BETTER BM-02 48 DF#2 OR BETTER BM-03 3.5"X9.25" PSL BM-04 5.25"x9.25" PSL BM-05 1.75"x11.875" LVL BM-06 3.5"x11.875" PSL BM-07 5.25"x11.875" PSL BM-08 3.5"x9" GLULAM BM-09 3.5"x10.5" GLULAM BM-10 5.5"x10.5" GLULAM BM-11 5.5"x12" GLULAM BM-12 W10x15 BM-13 W10x45 BM-14 W10x54 BM-15 410 PT HF#2 BM-16 7"x11.875" PSL HANGER SCHEDULE SYM. HANGER H-01 ITS2.37/11.88 H-02 LU210 / LUC210 H-03 HUCQ410-SDS H-04 HUC46 w/ (8) 1/41%TITEN2 SCREWS H-05 BA48 MAX NAILS H-06 HGUS7.25/12 H-07 HU11 H-08 HUC410 MAX NAILS H-09 BA3.56/11.88 H-10 HU11 H-11 HUCQ1.81/11-SDS H-12 BA4.75/11.88 MAX NAILS H-13 H-14 NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER 1 A8 i � , I I I I I I I I I I 1 NOTE ! P.L. POINT LOAD ABOVE. SOLID BLOCKING REQUIRED IN FLOOR FRAMING NOTE ! ALL FLOOR FRAMING MEMBERS TO BE 2x10 HF#2 OR BETTER @ 16" O.C.(U.N.O.) �- LEGEND CONCRETE WALL UNDER WALLS UNDER WALLS/ FIXTURES OVER FLOOR PERIMETER FLOOR JOISTS LANDING JOISTS STAIR STRINGERS HEADERS & BEAMS CONCRETE SLAB EXISTING 10/29 2021 y p,N N. ROS pE WASHiti S 21 44 46411 SSG/STERN 0NM- ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN RESUB o LL' Jul 25 2022 Q CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Q z W Z Q � 0 J � Q o W w od ILLJ Q W C-) Z Q L0 CL a� R 0 c 0 r a �L 0 6 Z PROJECT NO. 200302 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET: PR"DATE 10/29/2021 916 AM POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P-01 (1) 2x_ STUD w/ (1) TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-02 2x_ STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-03 (2) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-04 (3) 2x_ TRIMMERS (4) 16d NAIL (HEADER) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-05 (3) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-06 (4) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-07 6x8 DF#2 (4) 16d NAIL (DBL. TOP PLATE) (6) 16d NAIL (TOE PLATE) P-08 6x6 DF#2 14/S7 (6) 16d NAIL (SUB FLR/BLKG) P-09 HSS4x4x1/4 SEE 9/S7 SEE 9/S1 P-10 44 PT HF#2 EPC4Z ABU44Z w/ %"x5" TITEN HD P-11 44 PT HF#2 CC44 OR ECC44 (2) A35 w/ #9x2.5" SCREWS NOTE: SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE BEAM SCHEDULE SYM. BEAM BM-01 48 DF#2 OR BETTER BM-02 48 DF#2 OR BETTER BM-03 3.5"X9.25" PSL BM-04 5.25"x9.25" PSL BM-05 1.75"x11.875" LVL BM-06 3.5"x11.875" PSL BM-07 5.25"x11.875" PSL BM-08 3.5"x9" GLULAM BM-09 3.5"x10.5" GLULAM BM-10 5.5"x10.5" GLULAM BM-11 5.5"x12" GLULAM BM-12 W10x15 BM-13 W10x45 BM-14 W10x54 BM-15 410 PT HF#2 BM-16 7"x11.875" PSL HANGER SCHEDULE SYM. HANGER H-01 ITS2.37/11.88 H-02 LU210 / LUC210 H-03 HUCQ410-SDS H-04 HUC46 w/ (8) 1/4x1%4 TITEN2 SCREWS H-05 BA48 MAX NAILS H-06 HGUS7.25/12 H-07 HU11 H-08 HUC410 MAX NAILS H-09 BA3.56/11.88 H-10 HU11 H-11 HUCQ1.81/11-SDS H-12 BA4.75/11.88 MAX NAILS H-13 H-14 NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER LOWER ROOF VENT CALCULATIONS ROOF AREA 228 SQ FT REQUIRED ROOF VENTILATION AREA/ 300 0.76 SQ FT IN UPPER & LOWER ROOF ROOF VENT AREA/ 2 0.38 SQ FT NT BLOCKS IN EAVES BLOCKS = AREA/ 0.074 6 ROOF VENTS IN UPPER 40-50 % OPTION 1: AF50 ROOF JACK = AREA/ 0.333 2 2: (ridge vent) NT V300 = AREA/ 0.094 4.0 FEET 8 7 6 --------- a---------- L FI V 1 L V V n 1 1%P%1 V 1111 V SCALE: 1 /4" = 1'-0" FLOOR TRUSS NOTE: THIS LAYOUT IS FOR SCHEMATIC PURPOSES ONLY. REFER TO TRUSS FRAMING PLANS PER MANUFACTURER AND PREPARED BY A LICENSED TRUSS ENGINEER. ,A8 i NOTE ! P.L. POINT LOAD ABOVE. SOLID BLOCKING REQUIRED IN FLOOR FRAMING NOTE ! ALL ROOF FRAMING MEMBERS TO BE MANUFACTURED TRUSSES @ 24" O.C.(U.N.O.) HEADER NOTE ! HEADERS NOT CALLED OUT IN PLAN SHALL BE: No__ BM-01 Q� LEGEND TRUSSES OVER FRAMING WALLS UNDER WALLS/ FIXTURES OVER HEADERS & BEAMS FLOOR PERIMETER FLOOR JOISTS LANDING JOISTS STAIR STRINGERS LOWER ROOF LINES 10/29 2021 y p,N N. /?o pE WASHiti S 21 44 46411 /STERN ON 1, ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN CD Lij RES U B N Jul 25 2022 OO CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z W Z Q � 0 Q o W w DC °d LLJ C� Z J Q W o Z Q L0 CL 0 c O r a �L m O Z PROJECT NO. DESIGNED BY 200302 TL DRAWN BY TL & RM CHECKED BY TL SHEET: S5 PR"DATE 10/29/2021 912 AM POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P-01 (1) 2x—STUD w/ (1) TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4)16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8)16d NAILS STUD TO HEADER P-02 2x_ STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4)16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8)16d NAILS STUD TO HEADER P-03 (2) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4)16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-04 (3) 2x_ TRIMMERS (4) 16d NAIL (HEADER) (4)16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-05 (3) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4)16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-06 (4) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4)16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-07 6x8 DF#2 (4) 16d NAIL (DBL. TOP PLATE) (6) 16d NAIL (TOE PLATE) P-08 6x6 DF#2 14/S7 (6) 16d NAIL (SUB FLR/BLKG) P-09 HSS4x4x1/4 SEE 9/S7 SEE 9/S1 P-10 4x4 PT HF#2 EPC4Z ABU44Z w/ %8"x5" TITEN HD P-11 4x4 PT HF#2 CC44 OR ECC44 (2) A35 w/ #9x2.5" SCREWS NOTE: SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE BEAM SCHEDULE SYM. BEAM BM-01 48 DF#2 OR BETTER BM-02 48 DF#2 OR BETTER BM-03 3.5"1 PSL BM-04 5.25"x9.25" PSL BM-05 1.75"x11.875" LVL BM-06 3.5"x11.875" PSL BM-07 5.25"A 1.875" PSL BM-08 3.5'1 GLULAM BM-09 3.5' 10.5" GLULAM BM-10 5.5' 10.5" GLULAM BM-11 5.5' 12" GLULAM BM-12 W10x15 BM-13 W10x45 BM-14 W10x54 BM-15 410 PT HF#2 BM-16 7"11.875" PSL HANGER SCHEDULE SYM. HANGER H-01 ITS2.37/11.88 H-02 LU210 / LUC210 H-03 HUCQ410-SDS H-04 HUC46 w/ (8)1/41% TITEN2 SCREWS H-05 BA48 MAX NAILS H-06 HGUS7.25/12 H-07 HU11 H-08 HUC410 MAX NAILS H-09 BA3.56/11.88 H-10 HU11 H-11 HUCQ1.81/11-SDS H-12 BA4.75/11.88 MAX NAILS H-13 H-14 NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER ROOF PLAN NOTES • SEE DESIGN LOADS AND/OR STRUCTURAL NOTES FOR GROUND AND ROOF SNOW LOADS. . FOR MANUFACTUREDED TRUSS ROOFS: ROOF PLAN IS FOR SCHEMATIC PURPOSES ONLY. ACTUAL ROOF PLAN TO BE DESIGNED AND ENGINEERED BY A LICENSED TRUSS ENGINEER. RAFTER FRAMING PER PLAN. • TRUSS LAYOUT TO BE REVIEWED AND APPROVED BY THE TRUSS MANUFACTURER PRIOR TO CONSTRUCTION. • LOCATE DOWNSPOUTS PER SITE CONDITIONS AND PER GENERAL CONTRACTOR. • INSTALLATION OF ALL ROOFING AND WALL FLASHING SHALL BE TO INDUSTRY STANDARDS AND IN COMPLIANCE WITH CURRENT CODES. • PROVIDE CONTINUOUS ALUMINUM GUTTERS ON FASCIA AS SPECIFIED IN DETAILS. • SKYLIGHT SIZES, IF ANY, ARE APPROXIMATE. CONTRACTOR TO VERIFY ACTUAL ROUGH OPENING SIZE PER MANUFACTURER SPECIFICATIONS. • PROVIDE SOLID BLOCKING OVER ALL SUPPORTS. • PROVIDE MIN. 22"1 ATTIC ACCESS WITH APPROVED WEATHERSTRIPPING. IF ACCESS IS IN A GARAGE, A SELF CLOSING MECHANISM MUST BE INCORPORATED. • 16d @ 8"o.c. END TRUSS TO TOP PLATES. (TYPICAL AT ALL GABLE ENDS) • ATTICS WHERE THE MAX. CLEAR HEIGHT BETWEEN JOIST AND RAFTERS IS MORE THAN 42", OR WHERE THERE ARE TWO OR MORE ADJACENT TRUSSES WITH THE SAME WEB CONFIGURATION CAPABLE OF CONTAINING A RECTANGLE 42" HIGH BY 24" WIDE OR GREATER, MUST BE CONSIDERED ATTIC WITH LIMITED STORAGE. • ATTIC SPACE SERVED BY A FIXED STAIR SHALL BE DESIGNED TO SUPPORT THE MIN. LIVE LOAD FOR SLEEPING ROOMS. ,�A& -------------- & --------------- A 6 C D E F G H I I I I I i I I I I I I I I I I 2'_0" I j - -- - -_ -- I i O� J - - - I i I I I I I I III I A �O0 I i i I I 73 15o SV I I I i i I -I I I i I L7 C --- -- I � I F- I I i o I I; I 'I LEI I i i I I I e I, I I I I I I I I L� Go __ -_ 8 -_ - ' - O I IN O - — SOLID OVER G ___ --- ING WALLI ? J O� e z BM- BM 0 _�_ G ALL A ii I iF_ I ii I li L i1 I Li lii I I I„ I I "- A i 1 -- I J I I I I I ---� --- B BEA1 ___ --- SOLID B I I I I I I — OCKI ZINGALL i t I 1 I I I I i i ii - SOLIDI OVE I 1 I I I I I (ca B BIfA I -' i t I I I i 1 E I I i 1 II I I -_ —=_ -I----- I 1 it EI I —06 I I I W o IIZ ' __ it I I LL- ___ _--- CV OVER ] -_ __I_ ----------------- I -�- BLOC AR�N I I I ___ C-- � o O iI j l it ______-i E I I I I I I i i —� L --- --- ---- ----J --- I li i it - - I I _ I I - B --- LfGE --- v P � -- tiiA --- Ff I C_� _ — III III --_j iI1 I I HI II II - - i i I I I j I i I CJ L� I I I �- __i I I - 7 I C�I y_ r 1 I ,1 l� iIi I I 4 1 II ------� ------, I I I E I �Q I e1071 - r I I ttt T I I I I I I I I I I I I I I I I I I I I I I <04 D.Cc:o� ROOF PLAN SCALE: 1/4" = V-0" FOR SCHEMATIC PURPOSES ONLY. REFER TO TRUSS FRAMING PLANS PER MANUFACTURER AND PREPARED BY A LICENSED TRUSS ENGINEER. S8 1 A8 NOTE ! BUILT-UP TPO ROOFING WITH %" PER 12" SLOPE NOTE ! ALL ROOF FRAMING MEMBERS TO BE 11.875" BCI 6000 - 1.8 @ 16"O.C. HEADER NOTE! HEADERS NOT CALLED OUT IN PLAN SHALL BE: LEGEND BCI RAFTERS WALLS UNDER HEADERS & BEAMS ROOF LINES LOWER ROOF LINES (i z N co o co a � U Y 2 & w d.y n a)� C O _j J � � M CO w z 00NLU � N — IIX O am W m d W F— E O $ U . i C 'I�jiIIIIII!Iflllllllll(k -+ 111I'i�II � L I U LLj a°i °3` g` i -° m a c o m o 0 Z U E U1 .N -°Z5 d . L TzOIn �omc°�' ooca.m o as ¢z�_ N a O. au O O 0,75 O J N- C N "O O. �p N O "O N vl O mLLI O W ° 0 3 E i. rn rn c 3 c o° UJO o °o:..O d o 0 l-0Z wHa4). d�°.a@��,�vt zi, N z d m E> E m o .-J ¢ H O 10/29 2021 ypN N. /?o OF W AS,yiN S �n Z 21 44 46411 G/STER�� SS�ONAL ECG ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN RESUB Jul 25 2022 CD CV Uj CITY OF EDMONDS O DEVELOPMENT SERVICES MM DEPARTMENT W z >Q W z Q � O a W F LU LU z � Q W o Z a Lr) t7 c a 0 O Z PROJECT NO. 200302 TL DESIGNED BY DRAWN BY TL & RM CHECKED BY TL SHEET: S6 PRINT DATE 10/29/2021 912 AM DIAPHRAGM NAILING SCHEDULE NAIL SPACING NAIL SPACING AT AT BOUNDARIES INTERMEDIATE NAIL SPACING BLKG SIZE OF AND "OTHER" FRAMING AT BLOCKED LOCATION SHEATHING REQD NAIL PANEL EDGES MEMBERS PANEL JOINTS ROOF SEE STRUCT NOTES NO 10d 6" OC 12" OC 6" OC SUB-FLR NO 10d & GLUE 6" OC 12" OC 6" OC DIAPHRAGM NOTES 1. ALL DIAPHRAGM SHEATHING IS TO BE STAGGERED IN THE DIRECTION OF THE PLYWOOD SPAN PER DIAPHRAGM DETAIL 2. PROVIDE BOUNDARY NAILING CONTINUOUS AROUND THE ENTIRE PERIMETER OF THE DIAPHRAGM 3. NAILS SHALL BE COMMON OR GALVANIZED BOX 4. ALL FRAMING MEMBERS SHALL BE 2x MINIMUM NOMINAL WIDTH BLOCKED DIAPHRAGM TYPICAL CONTINUOUS WHERE INDICATED PANELJOINT - I �i, T BOUNDARY I 11 I1 11 W INAILING ER" 'BLOCKED ATE CONTINUOUSEIPANELJOINT 111 Il Il Il PANEL 1. 11 EDGE NAILING Ii Ii -. EI ]I: 11 INTERMEDIATE JOIST/TRUSS NAILING DIAPHRAGM DETAIL TYPICAL DIAPHRAGM NAILING 1 4 1/2" MIN. BEARING 2" 2) %"O x3" LAG SCREWS DBL SILL PLATE PER 8/S1 FOUNDATION WALL NAILER PER 18/S7 TYP W10x54 STEEL BEAM WITH COPED BOTTOM FLANGE YZ" PLATE PER 6/S4 STEEL BE....... Y4' NAILER PER 17/S7 STEEL BEAM PER PLAN WITH COPED BOTTOM FLANGE EACH I/4 SIDE _< M O) Ln 10" 1-1/2" MAX I, V-4 3/4" "PLATE SECTION 1 6 W10x15 STEEL BEAM %6"0"x4" PLATE WITH (2) %"0 A325N BOLTS `POST PERP PLAN (2) %"0 x3" LAG SCREWS SECTION 11 SCREW u�N SECTION 116 TOP PI 4 1/2" MIN. BEARING 2" (2) %"O x3" LAG SCREWS POST PER PLAN 4 1/2" MIN. BEARING -n "O x3" LAG SCREW EACH SIDE POST PER PLAN SHEAR WALL PER PLAN FLOOR BOUNDARY NAILING EDGE NAILING FLOOR BOUNDARY NAILING TAPERED JOISTS PER PLAN 2x4 CONT. BLOCKING WITH 16d AT 4" ox. TOP FLANGE HANGER PER PLAN - HANG FROM NAILER !off 1 11— 11 1`1 n —.1 n n o 1 A i ­1 NOTES: SEE STRUCTURAL NOTES FOR TYPICAL TOP PLATE NAILING NOT SHOWN TYPICAL TOP PLATE SPLICE 1 2 NAILER PER 17/S7 W10x54 STEEL BEAM WITH COPED BOTTOM FLANGE EACH 7—< SIDE \ m \ rn m Ln 10" 1-1/2" MAX I, V-4 3/4" 1-1/2" MAX "PLATE SECTION 1 7 NAILER PER 18/S7 STEEL BEAM PER PLAN WITH COPED BOTTOM FLANGE N c-I c-I EACH SIDE m � C I, V-11/2" N \ m SOLID BLKG MATCH WIDTH OF BEAM/GIRDER CRIPPLE STUDS AT 16" O.C. WHERE APPLICABLE TOP PLATES NAIL STUD TO HEADER W/ (8) 16d STUD(S) PER PLAN FULL HEIGHT TO TOP PLATES TRIM STUDS (TRIMMERS) PER POST PLAN BEAM/GIRDER TYPICAL HEADER DETAIL 1 3 m 1 1�/^2" 211 II /2I 1 Y4" CAP PLATE 1 N %6" KNIFE PLATE WITH H (4) a"0 A325N BOLTS MAIN FLOOR 0 0 PLATE OI 1O EACH 1/4 SIDE iv 1 I "I � I I N I I A SECTION STEEL BEAM PER PLAN TYP HSS COLUMN PER PLAN CENTERLINE OF BEAM AND COLUMN GRID 2 \ M N NAILER PER 18/S7 W10x54 STEEL BEAM WITH COPED BOTTOM FLANGE %" PLATE PER 6/S4 %" PLATE POST PERP PLAN SECTION 112 SOLE PLATE NAILING CONT. 2x6+"' PLYWOOD NAILED TO NAILER WITH (2) ROWS 16d x3.5" AT 6" o.c. 2x8 NAILER WITH %"O BOLTS AT 18" o.c. STEEL BEAM PER PLAN SECTION 117 2x CONT. NAILER WITH Yz"O BOLTS AT 24" o.c. STAGGERED. RIP TO MATCH STEEL BEAM WIDTH. FLOOR JOISTS PER PLAN 1IM FLANGE OF WT TRIM BOTTOM CORNER OF WOOD BEAM FOR RADIUS IN L8x6 PSL BEAM PER PLAN NOTCH BOT. OF BEAM AT 1 L6x4 SEAT L6x4x% x5.25" LLV (2) SDS25312 AT 2%" O.C. CENTERED IN HORIZ. LEG (2) WO x3" LAG SCREWS SECTION 113 (2) ROWS 10d AT 6" o.c. TOP FLANGE HANGERS PER PLAN STEEL BEAM PER PLAN SECTION 118 HOLD-DOWN ANCHOR SCHEDULE HOLD-DOWN ANCHOR IN CONC. STEM WALL ANCHOR IN THICKENED SLAB EPDXY ANCHOR IN EXISTING z FOUNDATION FLOOR TO FLOOR ANCHOR' HDU4 SB % x 24 PAB5 x 6" EMBED %$" DIA. x8" EMBED 8" DIA. HDU5 SB % x 24 PAB5 x 6" EMBED %$" DIA. x12" EMBED 8" DIA. HDU8 SB Y8 x 24 PAB7 x 8Y2" EMBED Y8" DIA. x16" EMBED %" DIA. HDU11 SB 1 x 30 PAB8 x 10" EMBED NA 1" DIA. HDU14 SB 1 x 30 PAB8 x 10" EMBED NA 1" DIA. NOTES: SON CS16 WITH (20) 1. F1554 THREADED '0 DBL. TOP PLATE ROD ANCHOR TYPE 2. EPDXY ANCHORS HOLD-DOWN PER PLAN SHALL ONLY BE USED D AT EACH SIDE. WHERE INDICATED SQUASH BLKG. JI AS NEEDED. ON THE FOUNDATION MATCH POST SIZE PLAN LL F PER PLAN NOTES: 1. USE THIS DETAIL AT ALL LOCATIONS WHERE BEAM WIDTH EXCEEDS 3%" AND/OR BEAM BOTTOM BEARING IS BELOW DOUBLE TOP PLATES. 2. EXTEND BEAMS FOR 5-1/2" BEARING ON 2x6 WALLS, 3-1/2" BEARING ON 2x4 WALLS. 0 w LL m w ANCHOR PER SCHEDULE ADD #4 x 48" AT EACH ANCHOR 41 _s TYPICAL PLATE STRAP AT BEAMS 4 TYPICAL HDU HOLD-DOWN ANCHORS 5 2" 11/4" 11/2" MAIN FLOOR PLATE ^ Ln 1/4 WT6x15 x7" WITH (2) a"o A325N BOLTS I I STEEL BEAM PER PLAN TYP SECTION A NAILER PER 19/S7 TRIM BOTTOM CORNER OF WOOD BEAM FOR RADIUS IN L8x6 PSL BEAM PER PLAN NOTCH BOT. OF BEAM AT L6x4 SEAT L6x4xY4 x5.25" LLV (2) SDS25312 AT 2Y4" D.C. CENTERED IN HORIZ. LEG EACH SIDE Y4"x6"x3" PLATE EACH SIDE WITH %"0 THRU BOLT 10d AT 6" ox. (2) ROWS 2x CONT. NAILER WITH %"O BOLTS AT 24" o.c. STAGGERED. RIP TO MATCH STEEL BEAM WIDTH. FLOOR JOIST PER PLAN HANGERS PER PLAN SECTION 1 Q Ln Ln 71 71 _� STEEL BEAM PER PLAN N \ POST PER PLAN SECTION 114 STEEL BEAM PER PLAN SECTION 119 A35 AT BLOCK AT CONCRETE WALL SHEAR WALL PER PLAN 10d AT 4" ox. TO BLOCKING SOLE PLATE NAILING FLOOR JOISTS PER PLAN EDGE NAILING FLOOR BOUNDARY NAILING CONT. 2x RIM JOIST SHEAR WALL SHEAR CLIPS JOIST BLOCKING AT 48" o.c. OR ALTERNATE PER 18/S8 • • DOUBLE SILL PLATE AND 3/4" MAX ANCHORS PER 8/S1 8" THICK WALL REINFORCED WITH #5 VERT. AT 12" O.C. WOOD FURRING (CENTERED) AND #4 HORIZ. AT 18" ox. AND (2) AT TOP DRAINAGE 12" THIC FREE-DRAINII FULL HEIGH DOWEI U rn W10x54 STE R PLAN SECTION 1151 c15 STEEL BEAM n6 " I vv I I H (2) Y4" 0 A325N BOLTS SECTION 1201 Ross Engineering Design Inc ryan.ross@rossengineer.com ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN RESUB Jul 25 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 CV LJIIIIIIJ 00 CA Q z LJIIIIIIIJ 0 z Q W O LU aLU W w 0 W I..L 0 Z Q LJIIIIIIIJ aLO m 0 AL �L N d 0 6 Z FILE/ NO. 20044 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S7 PRINT DATE 10 / 29 / 2021 STRUCTURAL WALL ABOVE PER PLAN WHERE APPLICABLE III I III I SOLE PLATE NAIL/SCREW EDGE NAILING III I FLOOR BOUNDARY NAILING III I II BLOCKING EACH END OF SHEAR WALL AND 48" o.c. SHEAR WALL SHEAR CLIPS EDGE NAILING ALIGN JOIST/BEAM PER PLAN OVER SHEAR WALL INTERIOR SHEAR WALL AT PARALLEL JOISTS 1 SOLE PLATE NAIL/SCREW FLOOR BOUNDARY NAILING 2x RIM JOIST SHEAR WALL SHEAR CLIPS SHEAR WALL PER PLAN SOLE PLATE NAIL/SCREW EDGE NAILING FLOOR BOUNDARY NAILING ROOF CONT. TYPICAL SHEAR WALL SCHEDULE NUMBER OF SHEAR WALL STUD/BLKG. SILL PLATE / SOLE PLATE FRAMING ANCHOR TO NAIL/SCREW 1, 2 SHEATHED EDGE 3 AT ADJOINING $ 9 SYMBOL SHEATHING SIDES NAILING PANEL EDGES s SIZE CONCRETE 7 TO RIM JOIST SHEAR CLIPS SW1, SW1P 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 3"x.131" NAIL 3"x.131" TOENAIL o @ 48" OC @ 6" OC @ 6" OC SW2, SW2P 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 24" OC SEE STRUCT @ 48" OC @ 6' OC SW3, SW3P 1 8d @ 4" OC 2x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 18" OC NOTES @ 32" OC @ 4' OC SW4, SWOP 1 8d @ 3" OC4 3x OR DBL. 2x6 2x 5/8" DIA. 16d BOX NAIL LTP4 @ 14" OC @ 24" OCC @ 3' OC SW5, SW5P 1 8d @ 2" OC4 3x OR DBL. 2x6 2x 5/8" DIA. 1 BOX NAIL IL LTP4 @ 10" OC @ 18" OCC @ @ 2.5" OC SW6P 2 8d @ 3" OC4 3x OR DBL. 2x6 3x 5/8" DIA. AB SDS25600 LTP4 @ 14" OC @ 18" OC @ 5" o.c. EA. FACE S'�y0 I� D EAR WALL O�� STHD I HOLD-DOWN ID SHEAR CLIPS PER SHEAR WALL SHEAR WALL KEY SCHEDULE WHERE APPLICABLE TYP. SQUASH BLOCKS IN RIM JOISTS AT ALL POSTS AND HOLD-DOWNS, ALL IIIII III III III III III I: I IIIII LEVELS. SEE TYPICAL POST BLKG. DETAIL TYP. I'I I'I I I I•I I•I I: BLKG PER SCHED AT HORIZ. I I ANCHOR TYPE HOLD-DOWN W/ I _ _I I _ _LI PANEL JOINTS w/ EDGE _ _ _ — - _ _ ANCHOR ROD PER HOLD-DOWN � _ r - � NAILING BOTH SIDES OF .I I I I I I SCHEDULE TYP. II II I'I I'I I'I I JOINT TYP. II II II II II II II' II II I II I 8d AT 12" o.c. NAILING AT ALL SHEAR WALL SCHEDULE NOTES INTERMEDIATE SUPPORTS I I I I I LOCATE VERTICAL PANEL I I 1. SHEAR WALLS NOTED AS "SW_" INDICATE "SEGMENTAL SHEAR WALL" PER DETAIL (RIGHT) I I I I I I I JOINT ON STUD w/ EDGE I I 2. SHEAR WALLS NOTED AS "SW P" INDICATE "PERFORATED SHEAR WALL" PER DETAIL (RIGHT). APPLY ALL SHEATHING, NAILING AND FRAMING REQUIREMENTS PANEL EDGE NAILING TYP. NAILING BOTH SIDES OF I I PER SCHEDULE TO THE FULL LENGTH OF SHEAR WALL INCLUDING AREAS ABOVE AND BELOW OPENINGS. JOINT I I 3. NAILS SHALL BE COMMON OR GALVANIZED BOX UNLESS NOTED OTHERWISE. SILL/SOLE PLATE W/ I I 4. WHERE NAIL SPACING IS LESS THAN 4"oc, STAGGER NAILS %". ANCHORS PER SCHED. TYP. MIN (2) STUDS AT EACH I I 5. ALIGN ALL VERTICAL ADJOINING PANEL EDGES WITH STUD PER SCHEDULE. PROVIDE BLOCKING PER SCHEDULE AT ALL HORIZONTAL ADJOINING PANEL EDGES. HOLD-DOWN UNLESS I I 6. 3x FRAMING MAY BE SUBSTITUTED WITH (2)2x NAILED TOGETHER W/ 16d MATCHING EDGE NAIL SPACING. STAGGER PER NOTE #4. ANCHOR TYPE HOLD-DOWN NOTED OTHERWISE PER 7. AT SW1 PROVIDE STANDARD CUT WASHERS AT ALL SILL BOLTS. AT SW2 AND HIGHER PROVIDE 3"x3"xY4" STEEL PLATE WASHERS. LOCATE EDGE OF WASHER PER PLAN WHERE APPLICABLE. PLAN OR POST WITHIN YZ" OF EDGE OF SHEATHED SIDE OF SILL PLATE. HOLE IN WASHER MAY BE DIAGONALLY SLOTTED 1.75" MAX. SEE SCHEDULE FOR ANCHOR SCHEDULE TYP. 8. ENSURE ONE CLIP EACH END OF SHEAR WALL AT EACH REQUIRED FACE OF SHEATHING. ROD TYP. 9. SHEAR CLIPS ARE REQUIRED ONLY AS INDICATED IN THE SECTIONS. STRAP TYPE HOLD-DOWN 10. SEE DETAIL (TOP FAR RIGHT) FOR TYPICAL TOENAIL SEGMENTAL SHEAR WALL PER PLAN TYP. 11. SEE DETAIL (BOTTOM FAR RIGHT) FOR BLOCKING AND SHEAR CLIP REQUIREMENTS AT DOUBLE SIDED SHEAR WALL EDGE NAILING HANDRAIL BY OTHERS FLOOR SHEATHING PER STRUCTURAL NOTES TYP FLOOR BOUNDARY NAILING RIM JOIST/BEAM MINIMUM WIDTH PER MANUFACTURER SHEAR WALL SHEAR CLIPS OR FLOOR JOISTS PER PLAN ALTERNATE PER 18/S5 EDGE NAILING SHEAR WALL PER PLAN SECTION 1 6 SHEAR WALL AT CANTILEVER 11 TRUSS TO BEAM 116 EDGE NAILING TO TOP PLATE Kuurbuur 2x CC WITF ROOF TRU SHEAR WALI HANGER PER PLAN AT'SIM' TIE WOOD — BEAM TO STEEL BEAM WITH DTT2Z AND Y"O ANCHOR WOOD BEAM PER PLAN SOLID WOOD BLOCK TIGHT BETWEEN STEEL BEAM FLANGES. PLANE FLUSH WITH STEEL BEAM FLANGES L G UARDRAI L ATTACH M ENT AND RIM BRACING PER MANUFACTURER FLOOR JOIST PER PLAN SECTION 1 7 SEE 15/S8 FOR SHEAR WALL CONNECTIONS NOT SHOWN NG FLOOR SHEATHING PER STRUCTURAL NOTES TYP FLOOR JOISTS PER PLAN SECTION 12 TRIM CORNERS OF BLOCK FOR STL. BEAM RADIUS `STEEL BEAM PER PLAN (4) %"0 THRU BOLTS 2" 1 1 1 4" SECTION 117 FULL HEIGHT SHEAR WALL PER PLAN ROOF BOUNDARY NAILING 2x BLOCKING WITH 16d AT 6" o.c. ROOF BOUNDARY NAILING CONT 2x SHAPED BLOCKING SHEAR CLIPS PER SHEAR WALL SCHED. EDGE NAILING SHEAR WALL PER PLAN SOLE PLATE NAIL/SCREW EDGE NAILING EDGE NAILING TO RIM JOIST FLOOR BOUNDARY NAILING EXTEND LOWER SHEAR WALL SHEATHING CONT. OVER RIM JOIST. DO NOT BREAK AT DOUBLE TOP PLATE. EDGE NAILING TO TOP PLATE EDGE NAILING H1 CLIP EACH TRUSS BEAM PER PLAN HANGERS PER PLAN 2x BLOCKING SOLE PLATE NAIL/SCREW FLOOR BOUNDARY NAILING JOISTS PER PLAN, BLOCKING AT 48" o.c. AT JOISTS PARALLEL TO BEAM. SECTION 1 $ OILAR SECTION PER :OR INFORMATION -IOWN FLOOR SHEATHING PER STRUCTURAL NOTES CONT RIM JOIST FLOOR JOIST/BLOCKING PER PLAN ALTERNATE SHEAR FLOW AT UPPER FLOORS 11$ SOLE PLATE NAIL/ EDGED EXTEND SHEAR WALL SHE, CONT. OVER RIM JOIST. I BREAK AT SOLE SHEAR WALL EDGE NAII RIM JOIST AND SIL BOUNDARY NAILING SOLID CONT. BLOCKING SHEAR WALL SHEAR CLIPS EDGE NAILING TO TOP PLATE SHEAR WALL PER PLAN TYP SOLE PLATE NAIL/SCREW EDGE NAILING FLOOR BOUNDARY NAILING 2x RIM JOIST SHEAR WALL SHEAR CLIPS, OR ALTERNATE PER 13/S8 EDGE NAILING SW P SHEAR WALL KEY �rr�r�rr�r� A34 EACH RAFTER WITH #9x1.5" SCREWS RAFTERS PER PLAN 2x6 STUDS AT 16" ox. TYP FLOOR JOISTS PER PLAN FRAMING PERPENDICULAR TO WALL FLOOR BOUNDARY NAILING SHEAR WALL PER PLAN PER DIAPHRAGM SCHED PT 2x LEDGER WITH SDS25312 AT 5" ox. STAGGERED TOP AND BOTTOM 2x SILL PLATE I DECK JOISTS PER PLAN FLOOR JOIST I HpuX HOLD-DOWN ID STRAP TYPE HOLD-DOWN CENTER ON RIM JOIST AT UPPER FLOORS TYP. PANEL EDGE NAILING TYP. PANEL EDGE NAILING ALL AROUND OPEINING m J TYPICAL TOENAIL BOUNDARY NAILING PER DIAPHRAGM SCHEDULE TO RIM JOISTAND BLOCKING CONT RIM JOIST PANEL EDGE NAILING SHEAR CLIP PER TYP. SCHED. EACH FACE FLOOR FRAMING DOUBLE SIDED \\—S`OLID BLKG. BETWEEN SHEAR WALL PER JOIST BLKG PLAN SHEAR CLIPS - DOUBLE SIDED SW SHEAR WALL SCHEDULE AND NAILING DETAIL rj BI SHEAR SOLE PLATE NAIL/SCREW EDGE NAILING FLOOR BOUNDARY NAILING 2x RIM JOIST SHEAR WALL SHEAR CLIPS, OR ALTERNATE PER 13/S8 EDGE NAILING FRAMING PARALLEL TO WALL (4) 10d TO BLKG AFTER PER PLAN - 48"oc 1.6" ox. Od TO BLKG )R JOISTS PER PLAN T BLKG AT 48"oc TYPICAL STRUCTURAL WOOD WALL/SHEAR WALL ASSEMBLIES 1151 SEE 8/S1 FOR ALL FRAMING AND CONNECTION INFORMATION NOT SHOWN 2x RIM JOIST 10d @ 4" o.c. FLOOR FRMG PER PLAN 2X SOLID BLKG FLOOR DIAPHRAGM SHTG PER STRUCT NOTES BLOCKING PER ' E' DTT1Z WITH SDS25312 24" 8/S1 SHEAR CLIPS PER SHEAR SIMILAR SECTION PER WALL SCHEDULE A34 EACH JOIST WITH i8 FOR INFORMATION WITHIN EACH END OF DECK #9x1.5" SCREWS - SHOWN AND AT 64" o.c. DBL TOP PLATE TO SILL PLATE EDGE NAILING SHEARWALL PER PLAN L+— ALTERNATE SHEAR FLOW AT LOWER FLOOR 118 SECTION 119 SECTION 2� Ross Engineering Design Inc ryan.ross@rossengineer.com ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN RESUB Jul 25 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 CV W 00 CA Q z LJIIIIIIIJ 7 Z Q W O too)0 a LU W w 1w co L1J Z Q W � 12 Z aL0 LO m 0 �L N d 0 6 z FILE/ NO. 20044 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S8 PRINT DATE 10 / 29 / 2021