Loading...
DNS_CONDITIONS OF ADU APPROVAL FOR REFERENCEFile No. PLN2021-0073 Pawling ADU Page 4 of 6 person, or a total of six unrelated persons. In no event shall the total number of occupants exceed one family as defined in this code. The property owner has submitted a notarized affidavit to the City confirming that they will reside in the primary residence or ADU for more than six months of every year (Attachment 2). The owner/applicant must also file the required covenant with the County Auditor following approval of the ADU, which has been added as a condition of approval. This covenant will be provided to the applicant for a signature and recording during the required building/compliance permit application review. 7. Safety, Light, Ventilation, Floor Area, and Similar Factors Safety, Light, Ventilation, Floor Area and Similar Factors. Accessory dwelling units shall comply with all applicable requirements of the Uniform Housing Code and the Uniform Building Code adopted by ECDC Title 19 and shall comply in all respects with the provisions of the Edmonds Community Development Code. No permit for an accessory dwelling unit shall be issued to a nonconforming structure unless that structure is brought into conformance with the then current provisions of this code. A condition of approval for this ADU has been added that requires compliance with the Building Division's inspection and compliance requirements. D. TECHNICAL REVIEW The subject proposal has been reviewed by the Building and Engineering Division. The Building Division did not have any specific comments on the proposal at this time but will be reviewing and providing comments under the associated building permit (BLD2021-1667). The Engineering Division provided a memorandum confirming that the application is consistent with Title 18 ECDC and Engineering standards, which includes parking requirements (Attachment 9). Snohomish County Fire District No. 1 will be reviewing and commenting under the associated building permit. Affected divisions/departments may have additional comments related to the proposal as part of their respective reviews of any associated building permit application(s). E. PUBLIC COMMENTS In accordance with ECDC 20.03, a "Notice of Application" dated January 26, 2022 with a comment period ending on February 9, 2022 was mailed to property owners within 300 feet of the subject site based on the adjacent property owners' list submitted by the applicant and was posted on the site on January 26, 2022. The notice of application was also published in the Herald Newspaper on January 26, 2022. All public notice materials, including the notice, adjacent property owner' list, declarations of mailing and posting, and an affidavit of publication are included as documents of compliance with the public notice requirements of ECDC 20.03 Attachment 10. No public comments were received during the comment period. F. DECISION Based on statements of fact, conclusions, and attachments in this report, the application for a Conditional Use Permit for an Accessory Dwelling Unit at 755 Daley St. is APPROVED, subject to the following conditions: 1. A building permit and/or compliance permit must be obtained from the Building Division and final inspection must be made and occupancy approval granted by the City Building Inspector prior to the area being used as an ADU. Specific comments from the Building Division will be addressed during review of the applicable building/compliance permit application. File No. PLN2021-0073 Pawling ADU Page 5 of 6 2. The ADU must remain below 800 square feet, the ADU void space on the western wall as shown on sheet A5 of the floor plan must remain for ADU size compliance. 3. This permit shall expire automatically if any of the following issues arise: a. The Accessory Dwelling Unit is substantially altered and is thus no longer in conformance with the plans and drawings reviewed and approved by the permitting authority and Building Official. b. The subject site ceases to maintain the required number of parking spaces. c. The property owner ceases to reside in either the primary residence or the Accessory Dwelling Unit, the owner -occupied unit is rented, or the current (or future) owner fails to file the affidavit required under ECDC 20.21.025(A)(1). 4. The Accessory Dwelling Unit Covenant must be filed with the Snohomish County Auditor. This covenant may be obtained from the Planning Division during the associated building/compliance permit application review. Prior to occupancy of the Accessory Dwelling Unit, the applicant must either (fees stated below are based on current fees and are subject to change): a. Provide the City processing fee ($110) plus the County recording fee (currently $203.50 for one page plus $1 for each additional page), and the City will record the covenant for you; OR b. Arrange to record the covenant with the County on your own for the County's recording fee (currently $203.50 for one page plus $1 for each additional page) and return a copy of the recorded covenant to the Edmonds Planning Division with the Auditor's recording sticker on the copy. 5. The Accessory Dwelling Unit permit shall not be transferable to any site other than the subject site described in the application. The Accessory Dwelling Unit permit is transferable to new owners of the subject property unless there is a violation of any conditions of approval listed above. New owners must file a notarized Accessory Dwelling Unit Affidavit with the City of Edmonds Planning Division. G. ATTACHMENTS 1. Land Use Application and Project Description 2. ADU Affidavit 3. Revised Site Plan 4. Revised Elevation and Floor Plan 5. Zoning Map / Vicinity Map 6. Letter of Completeness 7. Request for Additional Information 2-16-22 8. Applicant Resub Letter 3-3-22 9. Engineering Division Memo of Compliance 10. Public Notice Materials DOOR SCHEDULE - BASEMENT FLOOR SYM. NO. WIDTH HEIGHT DOOR TYPE COMMENTS BASEMENT FLOOR D1 T - 0" 6'- 8" SINGLE ENTRY- CONTEMPORARY (TEMP.) TEMP. GLASS (U=0.28) D2 2'- 8" 6'- 8" SINGLE PANEL D3 2'- 8" 6'- 8" SINGLE PANEL D4 2'- 8" 6'- 8" SINGLE PANEL D5 2'- 6" 6'- 8" SINGLE POCKET D6 2'- 6" 6'- 8" SINGLE PANEL D7 2'- 8" 6'- 8" SINGLE PANEL D8 2' - 8" 6' - 8" SINGLE PANEL 1 3/8" SOLID CORE w/ SELF CLOSING MECHANISM D9 5' - 0" 6'- 8" BI-PASS CLOSET DOOR D10 2'- 8" 6'- 8" SINGLE PANEL 1 3/8" SOLID CORE w/ SELF CLOSING MECHANISM D11 2'- 8" 6'- 8" SINGLE PANEL D12 8'-0" T - 0" OVERHEAD GARAGE DOOR INSULATED STEEL OVERHEAD DOOR D13 16' - 0" T - 0" OVERHEAD GARAGE DOOR INSULATED STEEL OVERHEAD DOOR D39 T - 0" 6' - 8" 1 SINGLE ENTRY - CONTEMPORARY (TEMP.) TEMP. GLASS (U=0.28) WINDOW SCHEDULE - BASEMENT FLOOR SYM. NO. WIDTH HEIGHT AREA WINDOW TYPE I U-VALUE COMMENTS BASEMENT FLOOR 1 16'- 0" 4' - 0" 24 SF SLIDER 0.28 TEMP. GL. 26 1' - 4" 16'- 0" 8 SF I PICTURE (FIXED) 10.28 1 TEMP. GL. Grand total 32 SF KEYNOTE SCH ELDU LE KEY VALUE TEXT 01 GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE OR 20 MIN. FIRE RATED RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING DEVICE. (R302.5.1) 02 LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 03 GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 & TABLE 302.6) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503) 06 GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) 07 STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6) 08 EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECS. AND IN STRICT ACCORDANCE W/ LOCAL BUILDING 09 CODES. MUST BE U.L. LISTED. (M1303/ G2427.2.1) 10 DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 12 PILOTS, BURNERS, & SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. 17 CLOSET ROD w/ VINYL COATED WIRE SHELF CLOSET SHELVING AND DRAWER ORGANIZERS PER BUILDER SPECS. 18 19 TEMP. GLASS DOOR 20 TEMP. GLASS WINDOW 22 ONE PIECE SHOWER WITH TEMP. GLASS SHOWER DOOR. 24 FIBERGLASS TUB w/ TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFICATIONS. 27 1/2" GWB UNDER STAIRWAY IN ENCLOSED SPACES. 28 HYDROBLOK OR EQUIV. SHOWER PAN w/ TILE SURROUND. PROVIDE TEMP. GLASS DOOR AND ENCLOSURE. CENTER OR CONCEALED FLOOR DRAIN PER BUILDER/OWNER SPECS. 29 TEMPERED GLASS SHOWER DOOR AND ENCLOSURE. 75 Q Q 0 Q w Z 00 1 EO HANDRAIL, GUARD AND BALUSTERS TO CONFORM TO I.R.C. OPENINGS SPACED SUCH Th'"T CANNOTI 75 N M z O Lu 10" MIN. TREAD Cl) N II II II II II I I I II II I II I II II �� FIRE BLOCK BETWEEN STUD 3/4" MIN; BAYS AT WALLS IN CONTACT 1 1/4" MAX. WITH STRINGERS. NOSING 1/2" MIN. PLYWOOD RISERS j) RESIDENTIAL STAIR -IRC i 3/4" = 1'-0" RESIDENTIAL STAIRS TO BE MIN. 36" (CLR) WIDE. 1 1/4" DIA. MIN; 2" DIA. MAX. HANDRAIL w/ RETURNS TO WALL. DBL. JOIST (U.N.O.IN PLAN) - SIMPSON LUS210 JOIST HANGER �- - SIMPSON A35 EACH SIDE OF STRINGERS - (1) LAYER 1/2" GWB -- 2x12 STRINGERS PER PLAN 8 7 — 3 2 — 2X4 STUD WALL VOID SPACE T B C D E F G H I I I I I I I I I I I I I I 36' - 6" 4'-6" oe 32'-0" 10'-01, 9'-3" 12'-9" 2 I I I I I Cti 18 _REFRIG.-- IPACE 04'KITCHEN I I J L1z] - 11 '" ° - ffV ® M N cF N D39 BATH D5 = PATIO T.O. 8 X9 60 — O BEDROOM 1 r A2 ELECT. WALL HEATER D2 08 �—jl ELECT. HEAT -� 2x6 WALL 3' - 0" S.D. b1) D3 CD DININ A.D.U. NTRY D1 02 I I o 1 -- CD LIDLT 11 1 /2" 5' - 10" ' 3'-6" N 10 D7 D9 20 26 LI ING RM. (2) LAYERS 5/8" TYPE "X" *0 O 17 GWB AT ADU CEILING. S.D. c.o. V.T.O. SEE DETAILS 3/A9 & 4/A9 M S THEY APPLY. 1 HR. WALL HEAT PUMP HEAD BETWEEN ADU D11 HANDRAIL AND MAIN HOUSE. 1 STACK WASHER 1 UP AND DRYER (V.T.O.) A9 O 07 Lo 01 01 ° ° 2 00 i u ii u q i D6 ii NEW WALLS GREY FILLED D8 SUB -PANEL A.D.U. SHUTOFF — INFILL EXISTIN 27 cc 3 12 02 DOOR 02 Electric heat pump water heater UNDER - E meeting the standards for Tier III UNDER STAIRS of NEEA's advanced water heating 4 - 5 1/2 6' - 0 1/2" 3' 9" specification INTERCONNECTEDii HEAT SENSOR PER R.O. FOR FUTURE Q R 314.2.3 ELECTRIC VEHICLE INTERCONNECTED CHARGING STATION,' HEAT SENSOR PER GARAGE R 314.2.3 5/8" TYPE "X" GWB AT GARAGE CEILING UNDER HABITABLE SPACE ABOVE. r PARTITION WALL _ _ _ _ - _ _ _ _ - - - _ - - 20' - 9 1/2" T� WATER SHUT-OFF ° FOR A.D.U. -4 e � Q a 1 CONCRETE STEPS, - PLANTER AND BIO-CELL PER SITE PLAN. 2'-0 2" 0" 0' 2' 4' 8' 1'-01. 8'-0" 2'-0" 16'-0" 2'-6" 9'-6" 20'-6" ABASEMENT FLOOR 16' 1/4" = 1'-011 ELECT. PANEL - MAIN HOUSE. LOCATION MAY CHANGE PER ELECTRICIAN. V z N C) O 00 z W Q E Q U IL Y = O way w In a� a J U LO � 0) M(O,O z (00 00N` LU � 0 °�' LU m 0 LU n 2 H LU Q m 06 o c141 CD z 00 01 J � W � H U Q z z O W Q z W H W LU W LULUU W Z W �a LU LU �o z o ,n o' z 0 o_ O Q 43) M C 0 .N 0 z PROJECT NO. 200302 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A5 PRINT DATE 2/20/2022 10:51:43 AM