REVIEWED Mechanical Calculations..................... RECEIVED REVIEWED BY CITY OF EDMONDS i Apr 21 2022 BUILDING DEPARTMENT simple meating system size: wasnln ion staie DEVE. LOPMEN�^SERV This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information BAILEY & PAWLING RESIDENCE LEIF HELLEREN - HELLEREN CONSTRUCTION Heating System Type: O All Other Systems OO Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) Edmonds 'V J AT =Indoor (70 degrees) -Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) F 3,923 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.3 32,365 Glazing and Doors U-Factor X Area = UA Instructions ate 0.280 658 184.24 Skylights U-Factor X Area = UA Instructions 0.50 0� Insulation Attic U-Factor X Area = UA Instructions R-38Advanced J 0.026 F7,652 42.95 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instruction 1 No Vaulted Ceilings in this project. --- Above Grade Walls (see Figure 1) U-Factor X Area UA In 6R-21Intermediate 0.056 2,608 146.05 Floors U-Factor X Area UA Instruc. in R-38 I 0.025 773 19.33 J Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions �R-21Interior I 0.042 J 343 14.41 Slab Below Grade (see Figure 1 F-Factor X Length UA Instructions R-10 Fully insulated � 0.303 45 13.48 Slab on Grade (see Figure 1) F-Factor X Length UA , 0.360 66 23.76 R-10 Fully insulated Location of Ducts Instructions I Duct Leakage Coefficient Conditioned Space J 1.00 Sum of UA 444.21 Figure 1. Above Grade 46 Envelope Heat Load 20,434 Btu / Hour Sum of UA x AT Air Leakage Heat Load 16,079 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 36,513 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 36,513 Btu / Hour Ducts in unconditioned soace: sum of buildina heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 45,641 Btu / Hour Buildino and duct heat loss x 1.40 for forced air furnace Buildino and duct heat loss x 1.25 for heat puma (07101113)