Loading...
ENG2022-0399+Other+7.22.2022_4.18.36_PM+3007586IN THE SE 114 OF THE SE 114 OF SECTION 18, T. 2 7N. , R. 4E. , W.M. CITY OF EDMONDS, SNOHOMISH COUNTY, WA. 0 SCOPE OF WORK 1. IMPROVEMENTS INCLUDING DESIGN OF STORM TRENCHES, CONSTRUCTION OF THE HOME AND ONSITE DRIVEWAYS. ENCROACHMENT NO: ENG 2013-0379 AND AFN 201309050209 ---------- ALLEY 59.95 - 170 EXISTING YARD & F LACING EXISTING DECK TO REMAIN I.r------a - - -. --- -- I I N I o ° I<DS d d I I� I I ° GRAPHIC SCALE EXISTING PATIO * MIN �- 0 10 0 5 10 20 TO REMAIN ■ I I 32:00' . 1 INCH = 10 FEET I �° I. ° TIE FOOTING DRAINS INTO c j '■' . . . . . . . . STORMWATER SYSTEM a I NEW. I RESIDENCE-, INSTALL BIORETENTION PLANTER I I = l TOP WALL: 98.00 o, 11.98 -1.. .. .. .. .. .. . IE IN: 97.40 4" DOWNSPOUTS IE OUT: i■r 94.41 4" PVC 104 I I. I L OVERFLOW: 97.50 4" PVC SIZE: 9' X 12' @ 108 SF (SEE DETAIL) I I I S I ---_LEW 1021 WALKWAY - AND STEELS I . ROCKERIES AND PAVERS S.F. - TO BE REMOVED 100 d 6LF 4" PVCS =1.25% I -.•. INSTALL NEW TYPE I CB INSIDE OF PROPERTY LINE RIM 95.70 +/- E IN 94.00 4" PVC IN - IE OUT 93.20 12" CPEP OUT TEMP, P-POLE -SD- G 14LF12"CPEP S=17.8%+/- SSMH /TOP 94.5 INSTALL NEW 1-INCH WATER METER AND RUN NEW 1-1/2 INCH SERVICE LINE TO HOME AND PROVIDE PROTECTION DURING CONSTRUCTION -SD- - -SD G -G - RIM 94.21± SADDLE TYPE II E 90.70± 12" NEW TIE INTO EXISTING STORM DRAIN LINE WITH NEW SADDLE TYPE II MANHOLE AND MATCH CROWN SECTIONS OF EXISTING STORM MAIN LINE WM, 1n IN ° ° d EXISTING PATIO 4:3- TO REMAIN ° I AREAS OF EX d DECKS/PATIOS TO REMAIN EXISTING STEPS AND RETAINING WALL a TO UPPER YARD AREA d I TO REMAIN. a I I I ° I° I■■r d , -2ND FLOOR I'. CANTILEVER a• •t <I I -NEW PATIO 52 S.F. 1 I. I NEW LANDING 4 S. F. I• I I BIORETENTION PLANTER (NON -INFILTRATING) WATERTIGHT, THREADED DOWNSPOUT OR INLET W/ CLEANOUT CAP SPLASH BLOCK OR ROCK PAD BOTTOM CELL AREA TW 98.D 24" MIN. WIDTH. 4" DIA, MIN. PONDING DEPTH -,_ (SEE NOTE 3) OVERFLOW PIPE W/ 'tom ATRIUM GRATE 611 3" COMPOST 45' WYE & MULCH LAYER 45° BE 18�� IE OUT 94.42 18 MIN. OVERFLOW PIPE 4° BIORETENTION S&L 22" IIII I'lllllllliiiiiii��l��llll 0.5%„SLOPE' „II lllllliiiiii DIA. MIN, (92% TO APPROVED DISCHARGE SEATTLE TYPE 26 POINT. SEE NOTE 6 AGGREGATE (WANED SANDY GRAVEL) 5" MIN. THICK REINFORCED 6" MIN. CL 3000 CONCRETE W/ 12" MIN ROCK THICKNESS 4" DIA. MIN. SLOTTED UNDERDRAIN 6"X6" WIRE VESH OR ON TOP AND SIDES OF PIPE (PER STD. PLAN 291) SEE NOTE 4. BETTER OR OTHER MATERIAL SEE NOTE 2 NOTES: 1. SHOW BIORETENTION PLANTER AREA & WALL DIMENSIONS ON THE DRAINAGE CONTROL PLAN. 2. ALTERNATIVE PLANTER WALL/BOTTOM MATERIALS ARE ALLOWED (EG. STEEL PLATES). IE THE MATERIAL IS NOT WATER -TIGHT, AN IMPERMEABLE LINER IS REQUIRED AND MUST EXTEND TO THE MAXIMUM WATER LEVEL. ADDITIONAL WATERPROOFING IS RECOMMEND FOR PLANTERS THAT ABUT BUILDINGS. 3. PLANTER BOTTOM SHALL HAVE A MINIMUM WIDTH OF 2 FEET (INSIDE DIMENSION) IN ANY DIRECTION, 4. SLOTTED DRAIN PIPE SHALL RUN THE LENGTH (LONG DIMENSION) OF THE PLANTER. 5. MINIMUM FREEBOARD SHALL BE 6". FOR PLANTERS WITH 10,000 SE OF CONTRIBUTING AREA OR MORE ADDITIONAL FREEBOARD MAY BE REQUIRED TO ENSURE TOP OF FREEBOARD IS 6" ABOVE THE 25-YEAR WATER LEVEL. 6. BMP SHALL CONNECT TO AN EXISTING OR NEW CB I NEW AND/OR REPLACED DRIVEWAY ROOF LINE SLOPES SHALL NOT EXCEED 14% SLOPE CONSISTENT WITH ECDC • I I 18.80.060 CO RIM 96.80 E 92.80 6" PVC I I o I EXTEND EX DRIVEWAY AND PROVIDE Do I PERVIOUS CONCRETE (SEE DETAIL �\ I C-7) VC ° ENTRY PROVIDE A CLEANOUT WITHIN 2' OF THE STRUCTURE, AND A 6" - a _ _ _ -t-NEW DECK OVER GARAGE CLEANOUT IS REQUIRED AT THE PROPERTY LINE. THE 6" CLEANOUT o SHALL HAVE A 12" CAST IRON CD 4RhVEWAY ° I LAMPHOLE COVER WITH '/2" HEX ° ° 25 LF 6" PVC S=7.20% BOLTS, 635 S.F. / CO RIM 95.00 ° d d / IE 91.00 6" PVC d Q � � NATURAL GAS TO BE CAPPED AT PROP. LINE AND REPLACED TO 59.95, HOUSE -�- 30 LF 6"SDR-35 S= 10.5% - }SD------I-SD- G-- �_ G-- /1I-- G G G DAI Y i _ W lz W STRtET SAW CUT PAVEMENT AND TIE INTO - EX SAN SEWER LINE w - SS CUT AND CAP SIDE SEWER AT PROPERTY LINE AND ABANDON UNDER GROUND OVERHEAD CABLE PHONE AND POWER UNDERGROUND ALL DRY UTILITIES TO THE NEW SFR.(PHONE, CABLE, POWER, ECT) NOTE: A MINIMUM OF 3' HORIZONTAL SEPERATION AND 1' VERTICAL SEPERATION SHALL BE REQUIRED BETWEEN DRY UTILITIES AND SEWER, WATER, AND STORM AND 5' FROM CITY MAIN LINES. SEWER NOTE MINIMUM 10' UTILITY SEPERATION SHALL BE REQUIRED BETWEEN WATER AND SEWER. CALL 2 BUSINESS DAYS BEFORE YOU DIG 1-800-424-5555 200 SEWER -DRAINAGE APPURTENANCES STANDARD PLAN NO291 REV DATE: DEC 2010 80' 80' 80 INVERT 60' 60' NOTES: 1. AST M D 2241 SDR 21 CLASS 200 PVC PIPE OR AST M D 1785 SCH 40. 2. SLOT DIMENSIONS ARE 0.064" WIDE X 1.00' LONG SPACED ALONG PIPE AT 0.3. ON CENTER. PVC SUBSURFACE DRAIN PIPE NOTE: CONTRACTOR TO POTHOLE AND VERIFY LOCATIONS AND INVERTS OF ALL UTILITIES PRIOR TO CONSTRUCTION DATE: APPROVED FOR CONSTRUCTION CITY OF EDMONDS CITY ENGINEERING DIVISION m m W m 0 0 w w > Li m 0 W a- 0 = m U Q V) w m T � u o m w Cr� U m m m 0 m w cU z z w i ai QQ w m 0 l 0 0 0 3� N �L�O�0N a_Z_ .° C", o W by 0> 1 I- V) w N IiJ ro N �o0000 z Ib 1 0� >m QQ�r (.0� _j � O o m Ll w _O V w 0 O CN N N � I I O N cv o (V < co c Q o� o a- Q J 0 z c:) z Q L_u w�w� � I _ c) = = _ 11 < I J 7 un CN O CN >- o Q r^ J� w �J�Q ca 0 J z LL Q Q z re � Q z w w oc o z Q w J C w U UO SHEET 4 OF 6 C4