ENG2022-0459+Site_Plan+9.7.2022_3.34.54_PM+3095182IN THE SE 114 OF THE SE 114 OF SECTION 18, T. 2 7N. , R. 4E. , W.M. CITY OF EDMONDS, SNOHOMISH COUNTY, WA. SCOPE OF WORK 1. IMPROVEMENTS INCLUDING DESIGN OF STORM TRENCHES, CONSTRUCTION OF THE HOME AND ONSITE DRIVEWAYS. ENCROACHMENT NO: ENG 2013-0379 AND AFN 201309050209 ---------- ALLEY — — 59.95 - 70 EXISTING YARD & F NCING EXISTING DECK TO REMAIN I N I O ° a \ DS — -- " EXISTING PATIO I I ° r76 — — — — — — TO REMAIN VV/-\Lr\VVN I' AND STEELS ROCKERIES AND PAVERS 74 S.F. TO BE REMOVED j 3 4 / �; CD 100 / J 3 ° 4 R.LVEWAY a ° Ln. 24LF 4" PVCS=1.25°/ % I 635 S.F. INSTALL NEW TYPE I CB INSIDE OF I a PROPERTY LINE RIM 95.70 ° E IN 92.50 4" PVC IN - — — 4- oCli It OUT 91.62 12" DIP OUT WM" TEMP,, P-POLE 34 LF 12" DIP S=0.5% --_SD--SD "I G G G W_ SAW CUT EX ASPHALT AND PATCH SSMH TOP 94.5 INSTALL NEW 1-INCH WATER METER AND RUN NEW 1-1/2 INCH SERVICE LINE LINE FROM WATER MAIN TO HOME AND PROVIDE PROTECTI0 DURING CONSTRUCTION TIE INTO EX CB- 5-LF DIP S=0.5% SET NEW CB TYPE 1 WITH SOLID LID RIM 93.50 IE IN 91.45 N 12" DIP IE OUT 91.45 W 12" DIP co 0 94 SS 59.95, v v SD— — D— — - G G— A� Y STRt—ET W SS — SS S ' IN SEWER NOTE: MINIMUM 10' UTILITY SEPERATION SHALL BE REQUIRED BETWEEN a EXISTING PATIO WATER AND SEWER. a TO REMAIN AREAS OF EX DECKS/PATIOS TO REMAIN EXISTING STEPS AND RETAINING WALL a TO UPPER YARD AREA TO REMAIN. I a I I ° a � I - 2ND FLOOR I CANTILEVER I —NEW PATIO 52 S.F. I I I —NEW LANDING I 4 S. F. NEW AND/OR REPLACED DRIVEWAY I I SLOPES SHALL NOT EXCEED 14% I.I- f.—ROOF LINE SLOPE CONSISTENT WITH ECDC l . I 18.80.060 CO RIM 96.80 j IE 92.80 6" PVC c EXTEND EX DRIVEWAY AND INSTALL 1 o DRIVEWAY DISPERSION TRENCH 2FT S, I X WIDE 6" DEEP W/DRAIN ROCK (SEE DETAIL C-4 & C-7) ° I ENTRY PROVIDE A CLEANOUT WITHIN 2' OF THE STRUCTURE, AND A 6" NEW DECK OVER GARAGE CLEANOUT IS REQUIRED AT THE 26LF26LF6' PVC PROPERTY LINE. THE 6" CLEANOUT °/6 SHALL HAVE A 12 CAST IRON q LAMPHOLE COVER WITH '/2" HEX INST�LL DRIVEWAY BOLTS, `DISP RSION CO RIM 95.00 TREfJCH IE 91.00 6" PVC NATURAL GAS TO BE CAPPED AT PROP. LINE AND REPLACED TO HOUSE vv SS G WE —G ��G— W W CUT AND CAP SIDE SEWER AT PROPERTY LINE AND ABANDON PROVIDE MIN 3' SEPARATION G SAW CUT PAVEMENT AND TIE INTO EX SAN SEWER LINE ° + 30LF 6'SDR 35 S 10.5 /° _ BETWEEN STORM LINE AND UTILITIES UNDERGROUND ALL DRY UTILITIES AND 3FT SEPARATION FROM WATER TO THE NEW SFR.(PHONE, CABLE, SERVICE LINE POWER, ECT) ""�<UNDER GROUND OVERHEAD CABLE NOTE: A MINIMUM OF 3' HORIZONTAL PHONE AND POWER SEPERATION AND 1' VERTICAL SEPERATION SHALL BE REQUIRED BETWEEN DRY UTILITIES AND SEWER, WATER, AND STORM AND 5' FROM CITY MAIN LINES. GRAPHIC SCALE 10 0 5 10 20 1 INCH = 10 FEET NOTE: 1) UTILITY PATCHES WITH LESS THAN 20-FT OF SEPARATION SHALL BE COMBINED AND FULL WIDTH OR HALF WIDTH OVERLAY SHALL BE REQUIRED DEPENDING ON THE EXTENT OF DISTURBANCE. WHERE UTILITY PATCHES FALL ENTIRELY WITHIN ONE TRAVEL LANE, THE OVERLAY SHALL EXTEND TO THE CENTER LINE OF THE ROADWAY. WHERE UTILITY PATCHES EXTEND INTO BOTH TRAVEL LANES THEN A FULL WIDTH OVERLAY SHALL BE REQUIRED. 2) NOTE: DEVELOPER RESPONSABLE FOR WATER SERVICE ASPHALT RESTORATION. 2% DRIVEWAY DISPERSAL TRENCH NOTE: CONTRACTOR TO POTHOLE AND VERIFY LOCATIONS AND INVERTS OF ALL UTILITIES PRIOR TO CONSTRUCTION CALL 2 BUSINESS DAYS BEFORE YOU DIG 1-800-424-5555 DATE: APPROVED FOR CONSTRUCTION CITY OF EDMONDS CITY ENGINEERING DIVISION m m 3 w 3 Ld I -I m Q o w \ w > w m w > U m w zU q z U Q (U WTI H H U u w w � U m m m m o m w cu cu z z CD � w � < of 1, (n Q w Q W 1 0 0 M J C-, 00 1 I— U) w N IiJ 7 N �o0000 z Ib 1 1 >�a) QQnr (� ON J W-- o O m Ii w O V w C) CN O N N QD z NN _ mob o (V Q oLij o a� Q 0 z c:) z Q L w w L1J i �� ��c) w = = _ Q I J C 7 oCNCL O >_N�z L.LjJQ o rj z w �J�Q om 0J z �_J Q Q z re � Q z w w oc c z Q �w J C w U SHEET 4 OF 6 C4