Loading...
FIR2023-0115+Fire_Alarm_Equipment_Specification_Sheets+11.29.2023_2.30.34_PM+3924398RECEIVED FIR2023-0115 Dec 04 2023 CITY OFEDMONDS Fire Alarm Device Replacement DEVELOPMENT SERVICES DEPARTMENT Job Number: 53434 53434 - City of Edmonds Library City of Edmonds Table of Contents Spec # Manufacturer Section Doc Name Doc # 1 Fire AlarmDevices Gamewell-FCI SLP BLK 1 Gamewell-FCI ASD PI-3 IV 2 Gamewell-FCI ATD L3 3 Gamewell-FCI MS 7AF 4 Gamewell-FCI P2WL 5 Fire Alarm Devices Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI, S3 Series Intelligent Fire Alarm Control Panel provides the latest innovative high -end processing power. It offers a simple, intuitive solution for the small to mid -sized fire alarm applications. In standalone or network configurations, the S3 Series complies with most fire alarm application requirements. It supports either of the following types of networks. • Up to 64 nodes using the 7100 Series panel. • Up to 122 nodes using the S3 Series or E3 Series® panels. Use either twisted -pair wire or fiber-optic to network panels at a high-speed 625K baud ARCNET network bus. With flexible Boolean logic, intelligent detection, and Ether- net connectivity, this system provides power and versatility that surpasses comparable, small addressable fire alarm systems. The basic S3 Series consists of an SLP (Smart Loop Panel) main board, LCD-SLP touchscreen display, SLC loop personality modules, and 7 amp power supply. The SLP provides either one or two SLC loops in Class A or B configuration that supports either of the following protocols: • Up to 318 devices per loop using the System Sensor® protocol. If you add a second loop module, it increases the maximum device count to 636 devices. • Up to 126 devices per loop using the Apollo protocol. If you add a second loop module, it increases the maxi- mum device count to 252 devices. Four Class B or two Class A NACs can be wired and syn- chronized using the System Sensor, Cooper -Wheelock, or Gentex strobes. To retrofit the SLP on the existing audible/ visual appliances, the on -board Electronic EOL (EEOL) automatically adjusts to the EOL resistor in the field. A 4.3" (10.92 cm) color touchscreen display screen shows the following: • Events on the system • Status of analog addressable devices • Complete diagnostic fault codes/messages • Five programmable function buttons with LED status for accessibility to the following functions: - Disable/Enable Trouble Acknowledge - Bypass Output Alarm Acknowledge - Lamp Test Custom -defined E3 Series® System Sensor® and FocalPoint® are registered trademarks of Honeywell IntWational Inc. ILL is a registered trademark of Underwriters Laboratories Inc. S3 Series control Panel Small Analog Addressable Fire Alarm S3 Series Features Control Panel • Listed per ANSI/UL® Standard 864 9th Edition. • IBC Seismic Certified. • Allows one SLC loop (expandable to two loops) that supports either System Sensor or Apollo devices in Class A or Class B (Style 4, 6 or 7). • System Sensor supports up to 318 intelligent devices and each SLC loop supports the following. up to 159 detectors. up to 159 modules (expandable to 636 maximum per panel). • Apollo supports up to 126 intelligent detectors and modules per SLC. (Expandable to 252 maximum per panel). • Includes a high resolution (4.3") (10.92 cm) color touch - screen display. • Supports a network system of up to 122 nodes (includes E3 Series® panels) or up to 64 nodes (includes 7100 Series). • Provides 7.0 amp power supply (120VAC or 240VAC). • Includes four Class B or two Class A built-in Notification Appliance Circuits (NAC). Provides selectable System Sensor, Cooper -Wheelock, or Gentex strobe synchroni- zation. • Supports up to 32 serial annunciators (LCD, LED -only, LED Switch). SIGNALING � City`Y of \/ FM M EA O Chicago C LISTED FDNY: Approved T E VMC Geo p S1869 APPROVED COA-061627165.1703:0176 CIa551 Reference Certificate of Compliance VMA-45894-02C ISO 9001 GAMEWELL-FCI II.AT, "°'`"` 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2014 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60730 Rev. F page 1 of 4 Application The S3 Series Fire Alarm and Life Safety System is an easy -to -use intelligent fire alarm solution designed for the small to mid -sized buildings. Analog technology delivers the benefits of a simple system installation, while a user- friendly interface makes panel operation and system main- tenance quick and intuitive. Smart Panel Programming Using Boolean logic programming, the installer may cus- tomize the system to precisely suit the needs of the build- ing owner. Auto -programming allows the installer to instantly locate all the devices on the SLC loop. Simple, Intuitive Display The front panel display provides a user-friendly interface for the operator's control. A 4.3" (10.922 cm) color touch - screen displays system status, event details and service modes. On the front of the panel, six LEDs show the follow- ing conditions. • Fire Silenced • Hazard (Gas or CO) AC Power • Supervisory Trouble Five custom programmable switches allow the user quick access to common functions specific to the building like device disable, output bypass and device status. Perfect for Retrofits The S3 Series is well -suited for retrofit applications. The SLP provides a simple way to upgrade your fire protection system. It is designed to be an upgrade solution for the leg- acy FCI 7100 and Gamewell 602 Series panels. An added feature is the SLP's EEOL. Using EEOL, the installers can automatically identify the EOL for existing audible/visual appliances. Flexibility for Future Growth The S3 Series can be expanded to add a second SLC loop without replacing the entire system. Using the RPT-E3- UTP Network Repeater, you can network up to 64 nodes (122 nodes with the ANX node expander) using either twisted -pair or fiber-optic. The built-in Ethernet port allows the connection to the Gamewell-FCI's FocalPoint Graphical Workstation. FJ i.°Z 0 Figure 1 LCD-SLP Display Features (Continued) • Offers an Ethernet port for programming, a variety of system reports, and a FocalPointR Graphic Workstation connectivity. • Provides two fully -programmable Form-C contacts for Fire, Trouble, and Supervisory. • TimeCap - Saves time and date up to 48 hours without any power or battery. • Automatically adjusts to any NAC End -of -Line Resistor (EOL) value (1 k-55k ohm) for legacy audible/visual appliances. • Removable display can be used as a remote annunciator. • Suitable for pre -action deluge applications. Optional Accessories DACT-E3 - Dialer The Digital Alarm Communication Transmitter sends digital signals over telephone lines to the central station. It con- nects to the SLP through an RS-485 bus. Using the Con- tact ID format, the DACT-E3 provides a four -digit account code followed by the code/numbers listed below: • Three -digit Event Code • Two -digit Group Number • Three -digit Contact Number All codes are used to provide specific point identification. The DACT-E3 is compatible with digital alarm communica- tor receivers (DACRs) that receive the following signaling formats: • Contact ID SIA 3+1 4+2 For more information, refer to the following data sheets: DACT-E3 Data Sheet, P/N: 9020-0610 FML-E3/FSL-E3 Data Sheet, P/N: 9021-60783 RPT-E3-UTP - Network Repeater Card The Network Repeater allows the SLP fire control panels to connect to the broadband network from remote locations. It connects to other networked units using unshielded, twisted -pair wiring. The RPT-E3-UTP is available with two add -on fiber modules: • FML-E3 connects to the network using either 62.5/125 micron multi -mode fiber. • FSL-E3 connects to the network using 9/125 micron single -mode fiber. Refer to the RPT-E3-UTP Data Sheet, P/N: 9020-0609. LCD-7100 - Remote Annunciator The Remote serial display features an 80-character dis- play. The LCD-7100 can be surface or flush -mounted on a standard 4-gang electrical box. You can use up to five LCD-7100 remote annunciators per SLP panel. For more information, refer to the LCD-7100 Data Sheet, P/N: 9020-0486. ASM-16 - Addressable Switch/LED Module There are 16 programmable switches available to perform any function the application requires. Each ASM-16 switch has 3 LEDs fully programmable in red, yellow, and green. These LEDs can be programmed to operate with a certain button press or operate independently as a status signal (e.g. ON, OFF, Activated, etc). Up to 16 ASM-16 modules can be connected to the SLP panel. For more information, refer to the ASM-16 Data Sheet, P/N: 9020-0554. ANU-48 - 48 LED Driver Unit The ANU-48 provides output for eight remote panel switches and 48 remote LEDs for use in a remotely located UL® Listed annunciator enclosure. Up to 16 ANU-48 mod- ules can be connected to the SLP panel. For more infor- mation, refer to the ANU-48 Data Sheet, P/N: 9020-0596. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60730 Rev. F page 2 of 4 www.gamewell-fci.com Figure 2 illustrates the SLP-BB Cabinet Enclosure. SL Ol Figure 2 SLP Enclosure Supports up to 636 Velociti devices or 252 XP95 devices DNR Intelligent Duct MCS COF Detector F., ICarbon Mon*,id, / Detector k r�i �it ASD-PL2F Photo Detector I ASD-LS Laser Detector — I — 1/8"H Specifications Device Loops Up to two Class A or B, System Sensor units, each loop supporting up to 318 device addresses. Or - Apollo units, each loop supporting up to 126 device addresses per loop. NAC circuits 4 Class B or 2 Class A (2.0 A each circuit), 6.0 A total NAC Operating Voltage 24 VDC NAC Minimum Voltage 19.5 VDC @ 20.4 V battery voltage SLC Loop Circuit Operating Voltage 24 V peak -to -peak Input Voltage 120 VAC, 60 Hz 240 VAC 50-60 Hz Input Current 120 VAC, 2.75 amps max. 240 VAC, 1.4 amps max. Aux Power 1 (Continuous) 24 VDC nominal at 1.OA Aux Power 2 (Resettable) 24 VDC nominal at 1.OA Base Panel Current draw Standby: 0.111 amps Alarm: 0.243 amps Operating Temperature 32e-120e F (0n-49e C) Relative Humidity 93% (non -condensing) Battery Charger Voltage +24 VDC Battery Charger 55 A/H batteries (cabinet Capacity accommodates 12 A/H batteries) Alarm, Trouble & Supervisory Relay Contacts Form-C, 2 amps @ 24VDC (resistive) Cabinet Dimensions: SLP-BB Dimensions 14 1/2" W x 20 1/8" H x 4 1/2" D (36.83 W x 51.18 H x 11.43 D cm) S3BB-RB Dimensions 19 3/8" W x 19 3/8" H x 4.5" D (49.22 W x 49.22 H x 11.43 D) S3 Series Fire Alarm Control Panel a Networkable up to 122 0 panels using twisted pair wire or fiber optics. AMM-21F AMM-2RIF Mini Monitor Module Dual Input/Output Module Local Energy E3 Series 1\\ Eq Trip Panel A W7,-, N AOM-2RF MS-7AF a 1< EthernetRelayModule Pull Station (A13 LCD-7100 LCD-SLP LCD-E3 -n Remote Annunicator Color ToucM1screen Remote Annunicator ...m C An 3 - n FocalPoint Workstation �L. 1 ASM-16 ANU-48 Laptop LED Switch Control LED Display Driver Programming Figure 3 SLP Panel Configuration GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA e Tel: (203) 484-7161 a Fax: (203) 484-7118 www.gamewell-fci.com 9021-60730 Rev. F page 3 of 4 �i Ordering Information Part Number Description SLIP -BILK SLP addressable FACP in black SLP-BB enclosure. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLP-RED SLP addressable FACP with red door and black SLP-BB backbox. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLP-RED-G SLP addressable FACP 240VAC power supply with red door and black SLP-BB backbox. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLC-PM System Sensor Loop Card - 1 loop used for 159 sensors and 159 modules. For use with the SLP-E3 panels only. SLC95-PM Apollo Loop Card-1 loop used for 126 sensors and modules. For use with the SLP-E3 panels only. Ordering Information (Continued) Part Number Description Accessories DACT-E3 Digital Dialer Communicator Transmitter for the S3 or E3 Series. LCD-SLP LCD Color Touchscreen display with five programmable switches. For use with the S3 Series panels. Remote annunciation requires the E3 Series A2 cabinet. (E3BB-BA2, E3BB-RA2) RPT-E3-UTP Network repeater card with twisted - pair fiber connections require either an FML-E3 or an FSL-E3 card. FML-E3 Multi -mode fiber-optic card for one channel on the RPT-E3-UTP. FSL-E3 Single -mode fiber-optic card for one channel on the RPT-E3-UTP. SLP-RB SLP motherboard For use with the replacement or the retrofit solutions. FLPS-7-RB SLP 120VAC 7A power supply. For use with the replacement or the retrofit solutions. SLP-RETROFIT SLP Retrofit Kit for the 7100 B-Slim and IF602 panels. Includes the new door and the mount- ing plate. Requires the following: • SLP-RB LCD-SLP • SLC-PM/ FLPS-7-RB SLC95-PM S3BB-RB SLP red cabinet with an inner door for the mounting display behind the plexiglass. Requires the following: • SLP-RB LCD-SLP • SLC-PM/ FLPS-7-RB SLC95-PM LCD-7100 Remote Serial LCD Annunciator ASM-16 Remote Programmable Addressable Switch/LED Module ANU-48 Remote LED Driver Module GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60730 Rev. F page 4 of 4 www.gamewell-fci.com Honeywell I Addressable Devices SGamewell Velociti" Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI, Velociti° Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern brightwhite color, the Velociti Series 3 is aesthetically pleasing fortoday's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI, ASD-PL3 photoelectric detector's re -designed optical sensing Photoelectric Detector chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment. The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR (DNRW) duct smoke detector housing. The ASD-PTL3 multi - sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 1350F fixed temperature thermal sensing. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number after the detector model. Note: Although the E3 Series° and S3 Series panels support both the Velociti° and CLIP" protocols, the GWF-7075 panel does not support the CLIP protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL° • Contains a built-in • Provides rotaryaddress • Includes dual LEDs for • Offers expanded color Standard 268 7th functional test switch switches(01-159) 3601visibility options Edition activated by external •Supplies optional relay, • Designed with a new magnet isolator, or sounder profile to offer modern • Supports a low standby bases (standard or low and improved current frequency) aesthetics Ordering Information NOTE: "-IV" suffix indicates Ivory color model. NOTE: "-BL' suffix indicates Black color model. NOTE: "WH" suffix indicates Bright White color model. ASD-PL3: Photoelectric smoke detector, bright white, Velociti ASD-PL3R: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, bright white, Velociti ASD-PTL3: Photoelectric smoke detector with thermal sensing, bright white, Velociti ASD-PL3-IV : Photoelectric smoke detector, ivory, Velociti/ CLIP ASD-PL3R-IV: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, ivory, Velociti/CLIP ASD-PTL3-IV : Photoelectric smoke detector with thermal sensing, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. Note: "IV" suffix indicates Flashscan and CLIP devices. "WH" suffix indicates bright white B501-WHITE: 4" Flangeless mounting base, bright white B501-WHITE-BP:4" Flangeless mounting base bulk pack, bright white B501-IV: 4" Flangeless mounting base, ivory B300-6: 6" Flanged mounting base, brightwhite B300-6-IV: 6" Flanged mounting base, ivory B300-6-BP: 6" Flanged mounting base bulk (Pack of 10) B200SR-WH: Standard sounder base, brightwhite B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable low frequency sounder base, bright white B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory DNR: Intelligent duct detector housing, non -relay DNRW: Intelligent duct detector housing, non -relay, watertight 2 Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for B300 6" Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single -gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCSCOF Series detectors. (Pack of 10) CK300-BL: Black detector kit. (Pack of 10) CK300-IR-BI: Black, detector color kit for use with MCSCOF Series detectors. (Pack of 10) M02-04-01: Detectortest magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/ or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5-foot (1.524,m) sections. Velociti° Series 3 Detectors Technical Specifications SYSTEMS Photoelectric Intelligent Detector: Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.49 cm) installed in B300-6 base 4 inches (10.16 cm) installed in B501 base Shipping Weight: 3.4 oz (96.4 g) Operating Temperature Range: Photo: 32' F to 122' F (Do C to 50' C) Photo in Duct Applications: -41 F to 1581 F (-20° C to 70' C) Photo with Thermal: 32' F to 100' F (Do C to 38' C) Operating Humidity Range: 10%to 93% non -condensing Rate -of -Rise Detection: Responds to greater than 151F/minute or 135°F (8.3° C/minute or 57°C Air Velocity Range: 0 to 4,000 ft/min (0 to 1219.2 m/min) Electrical Specifications Voltage Range: 15 to 32 VDC Standby Current (@ 24 VDC): 200 UA (one communication every 5 seconds with green LED enabled) Max Alarm Current (irri 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 For more information Learn more about Gamewell-FCI's Velociti® Series 3 Detectors and other products available byvisiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS The Velociti° Series 3 Photoelectric Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2332 FM:3023594 M EA FDNY: COA-219-02-E Vol. VI CSFM: 7272-1703:0501 ISO 9001 Certification 9020-0617 1 K 1 04/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series®, Velociti° and Gamewell-FCI° are registered trademarks of Honeywell International Inc. UL° is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. Honeywell Honeywell I Addressable Devices QGamewell Velociti° Series 3 Detectors Thermal Detectors Description The Gamewell-FCI, Velociti° Series 3 intelligent thermal detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern brightwhite color, the Velociti Series 3 is aesthetically pleasing fortoday's contemporary buildings. The Velociti Series 3 heat detectors are intelligent addressable detectors with point ID capability that enable each detector address to be setwith rotary address switches providing exact device locations. The thermal detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. Velociti Series 3 thermal detectors provide cost-effective, intelligent property protection using the following single thermistor: • ATD-L3 offers 135°F fixed thermal detection. • ATD-L3R offers 135°F fixed and rate -of -rise thermal detection. • ATD-L3H provides fixed high -temperature detection at 190°F. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number that appears after the detector model. Note: The E3 Series® and S3 Series panels support both the Velociti° and CLIPI protocols, and the GWF-7075 panel supports only the Velociti" protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS Thermal Detector • Complies with UL° 268 • Contains a built-in Provides rotary address • Includes dual LEDs Offers expanded color 7th Edition functional test switch switches (01-159) used for 3601 visibility options activated b an • Designed with anew y • Supplies optional relay, profile to offer modern external magnet isolator, or sounder and improved Supports a lowstandby bases (standard or low aesthetics current frequency) Ordering Information NOTE: '-IV" suffix indicates Ivory color model. NOTE: "-BL' suffix indicates Black color model. NOTE: "WH" suffix indicates Bright White color model. ATD-1-3: Thermal heat detector, 135°F fixed, bright white, Velociti ATD-L3-IV: Thermal heat detector,1350F fixed, ivory, Velociti/CLIP ATD-L3R: Thermal heat detector,135°F rate of rise, bright white, Velociti ATD-L3R-IV: Thermal heat detector,1350F rate of rise, ivory, Velociti/CLIP ATD-L3H: Thermal heat detector,190°F high temp, bright white, Velociti ATD-L3H-IV: Thermal heat detector,190°F high temp, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. B501-White: 4" Flangeless mounting base, bright white B501-White-BP: 4" Flangeless mounting base bulk pack, brightwhite B501-IV: 4" Flangeless mounting base, ivory B501-BL 4" Flangeless mounting base, B300-6: 6" Flanged mounting base, bright white B300-6-IV: 6" Flanged mounting base, ivory B300-6-BP: 6" Flanged mounting base bulk pack B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B20OS-WH: Intelligent addressable sounder base, bright white B20OS-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard lowfrequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B20OS-LF-WH: Intelligent addressable low frequency sounder base, bright white B20OS-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for B300 6" Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single -gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-I R: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCS- COF Series detectors. (Pack of 10) CK300-BL: Black detector kit (Pack of 10) CK300-IR-BI: Black, detector color kit for use with MCS- COF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5- foot (1.524,m) sections. Velociti° Series 3 Detectors Technical Specifications SYSTEMS Thermal Intelligent Detector Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.6 cm) installed in B300-6 base 4 inches (10.2 cm) installed in B501 base Shipping Weight: 3.4 oz (95 g) Operating Temperature Range: Thermal 135" Ffixed: -41 Fto 1001 F (-20° C to 380 C) Thermal 135' F rate -of -rise: -4° F to 100' F (-20° C to 380 C) Thermal 190° F rate -of -rise: -41 F to 1351 F (-20° C to 57' C) Operating Humidity Range: 10%to 93% non - condensing Rate -of -Rise Detection:: Responds to greater than 151F/minute or 135°F (8.3° C/minute or 570C Electrical Specifications Voltage Range::15 to 32 VDC Standby Current (@ 24 VDC): 200 uA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.):: 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.):: 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating:: 0.0063 For more information Learn more about Gamewell-FCI's Velociti® Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS The Velociti° Series 3 Thermal Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL:S2332 FM:3023594 MEA-FDNY: 219-02-E Vol. VI CSFM:7270-1703-0502 ISO 9001 Certification 9020-0620 1 G 1 04/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewelt- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series°, Velociti® and Gamewell-FCI° are registered trademarks and CLIP'" is a trademark of Honeywell International Inc. UL` is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. Honeywell Honeywell am.." MS-7 Series Addressable Devices Manual Fire Alarm Pull Stations General The Gamewell-FCI, MS-7 Series man ualfire alarm pullstations are available in a wide variety of configurations. The pullstations comply with the Americans with Disabilities Act(ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All pullstations include a key lock/resetwhich is keyed alike with the Gam ewe ll-FCI fire alarm control panels and other man ualfire alarm pull stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti' Series addressable station is a double action pull station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the pull station causes its assigned address to register at the fire alarm control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated The station features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable pull station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog MS-7 Series addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the pull station is activated.* The station features screw terminals. The Velociti® Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and focuses on the single device. The net effect offers a response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. FEATURES & BENEFITS • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • The pull stations (MS- 7LOB) are Listed for outdoor applications • Complies with ADA pull force requirements • Offers surface or semi - flush mounting • Shock and vibration resistant • Conventional stations Both single and double suitable for use with action pull stations any UL Listed control available panel • Includes a tumbler lock for test and reset keyed alike with analog addressable fire alarm controls *Only the red LED is operative in panels that do not operate in Velociti mode MS-7S Single Action Station The MS-7S single action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action pull station similar to the MS-7 station, with the additional feature of including both English and Spanish instructions molded into the unit. MS-7LR Dual -action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of single pole contacts and screw terminals used to connect to an initiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell- FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabilities are required. It consists of the following: • An MS-7LR mounted on a plate with an abort switch • LED indicators that signal system normal and system activated status MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-7LOB station must be mounted on a Model SB-1/0 backbox. In retrofit applications, the pull station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior pull stations may be surface mounted or semi -flush mounted on a standard double -gang, or4-inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi -flush mounting. 2 NYC -Plate The NYC -Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC -Plate Ordering Information MS-7: Double action station MS-7AF**: Velociti addressable double action station MS-7ASF**: Velociti addressable single action station MS-7S: Single action station, wire leads MS-7SP: Double action station, English and Spanish instructions MS-7LR: Agent release station, dual -action MS-7LRA: Agent release station with abort switch, LED indicators, dual- action MS-7LOB: Double action station, outdoor use (Includes SB-1/0 - Indoor/outdoor use backbox) SB-I/O: Indoor/outdoor use backbackbox SB-10: Surface backbox BG12TR: Trim ring for semi -flush mount, plastic NY -PLATE: NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. MS-7 Series Technical Specifications SYSTEMS STANDARDS For a complete listing of all Material: Lexan� lihlli The MS-7 Series is designed to com wth the following g p y g compliance approvals and certifications, please visit: Contact Ratings: 0.25 amps. C 30 VAC/VDC (resistive) standard: http://www.gamewell- Dimensions: 5 5/8" H x 41/4" W x 1 1/4" D UL Standard: UL 864 9th Edition fci.com/en-US/ (14 x 10.1 x 3.2 cm) AGENCY LISTINGS AND APPROVALS documentation/Pages/ Listings.aspx Operating Temperature: These listings and approvals apply to the modules LEXANI is a registered (MS-7AF, MS-7ASR 320 to 1200 F (00 to 490 C) specified in this document. In some cases, certain trademark of GE Plastics, a (MS-71-013): -30° to 150' F (-350 to 66' C) modules or applications may not be listed by certain subsidiary of General Electric Relative Humidity: approval agencies, or listing may be in process. Company. (MS-7AF, MS-7ASF):10 to 93% (non -condensing) Consult factory for latest listing status. Velociti° and Gamewell-FCI (MS-71-0131): 85%± 5% @ 860 ± 3.60 (300 ± 20 C) UL: S2465 are registered trademarks of Alarm Current:.0030 amp. 0.007 for LED FM: 3023594 Honeywell International Inc. Supervisor Current: Y MEA FDNY: 67-02-E Vol. VII . UL`is a registered trademark (MS-7AF, MS-7ASF):.00030 amps. CSFM: of Underwriter's Laboratories TEMPERATURE AND HUMIDITY RANGES 7160-1703:0119 Inc. 7160-1703:0170 This system meets NFPA requirements for operation at 0 This document is not intended - 490C/32 -120OF and at a relative humidity 93%± 2% 7160-1703:0109 to be used for installation PH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). ISO 9001 Certification purposes. We tryto keep our However, the useful life of the system's standby batteries product information up -to - and the electronic components may be adversely affected date and accurate. We cannot by extreme temperature ranges and humidity. Therefore, cover all specific applications or anticipate all requirements. it is recommended that this system and its peripherals be All specifications aresubjectto installed in an environment with a normal room change without notice. temperature of 15 - 270C/60 - 80°F. For more information Learn more about Gamewell-FCI's MS-7 Series and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 9020-0616 1 F 1 11/17 Honeywell ©2017 Honeywell International Inc. oi�� SYSTEM � SENSOR' Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts r F I R E • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Strobes and Horn Strobes listed for wall mounting only • Horns listed for wall or ceiling use Agency Listings SIGNALING S F M APPROVED 0 LISTED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS865-05 • 2/22/2018 • Page 1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuif' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6"L x 4.7-W x 1.91-D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.25-D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05 • 2/22/2018 • Page 2 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (mA RMS), Wall Horn Strobe, Candela Range (15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non -Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non -Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non -Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. AVDS865-05 • 2/22/2018 • Page 3 L-Series Dimensions 1.91' 3.46" 48.5 mm 88 mm 1.25' 3.46" 88 mm 1.25' 3.57" 1.55" 32 mm (9.1 cm) (3.9 cm) 32.. �O O a ° 0oo0°o°0o6° 090o000° LIPo c°°c° 5.38' 5.27„ d 4L_�_�_°'4 133.9 mm 5.27" �°0°p0Q°1°D°0 °°n°°°°°°°a°° (13.7 cm) O 133.9 mm °o°n°o°o°n°o° A�0°°�°VOA°0° oao�n nao�nro�e�o � Oao�000ao o O G� A0548-00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL 4.70' (11.94 cm) (4.85 cm) 1.25" (3.18 mm) (14.4 cm) L " Strobe, Horn Strobe A0550-00 L-Series Ordering Information Horn 1.25" 4.82" 32 mm (1224 cm) 1.9 (4.69 cm) 4 UP O ® O 5O 14.6 8 cm) A0549-00 A0554-01 Wall Surface Mount Back Box SBBRUSBBWL Wall Horn Strobes Horns* P2RL 2-Wire, Horn Strobe, Red HRL* Horn, Red P2WL 2-Wire, Horn Strobe, White HWL* Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL* Compact Horn, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White HGWL* Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBWL Wall Surface Mount Back Box, Red P4RL 4-Wire, Horn Strobe, Red SBBWL Wall Surface Mount Back Box, White P4WL 4-Wire, Horn Strobe, White SBBGRL Compact Wall Surface Mount Back Box, Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box, White SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -SIP models have "FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. "Horn -only models are listed for wall or ceiling use. 3825 Ohio Avenue 9 St. Charles, IL 60174 ©2018SystemSensor SYSTEM . Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsensoccom SENSORa www.systemsensor.com y for current product information, including the latest version of this data sheet. temsensor.com AVDS865-05. 2/22/2018