Loading...
REVIEWEBLD2023-1466+Manufacturer_Specifications_and_Installation_Instructions+11.15.2023_4.52.01_PM+3903379REVIEWED BY RECEIVED 17573CB O CITY OF EDMNDS BLD2023-1466 pad Calculation Nov 16 2023 CITY OF EDMONDS General Requirements DEVELOPMENT SERVICES ITEM #69 DEPARTMENT Room Temperature: 35 OF Ambient Temperature: 90 OF Design Run-time: 16 Hrs Required Capacity: 13,200 BTUH Area Load Section Material Thickness X - Factor Wall 1 Polyurethane 4 in 0.1 Wall 2 Polyurethane 4 in 0.1 Wall 3 Polyurethane 4 in 0.1 Surface Temp Dim. 1 Dim. 2 Load 75 °F 15.3 ft loft 5,124 BTU 75 °F 9.5 ft loft 3,192 BTU 75 OF 15.3 ft loft 5,124 BTU Wall 4 Polyurethane 4 in 0.1 75 OF 9.5 ft loft 3,192 BTU Ceiling Polyurethane 4 in 0.1 110 OF 15.3 ft 9.5 ft 9,127.1 BTU Floor Polyurethane 4 in 0.1 Product Load - Auto Usage Selected 65 OF 15.3 ft 9.5 ft 3,650.9 BTU Total Area Load: 29,410 BTU Air Change Load Total Product Load: 55,632 BTU Dry Bulb: 95 OF Wet Bulb: 75 OF Door Type 1: Man Number of Door Type 1: 1 Door Usage: Average Door Type 1: Curtains: None Door Type 1 Curtain Efficiency: 0% Total Door Type 1 Load: 16,800 BTU Total Air Change Load: 73,485.8 BTU Miscellaneous Load People Load: 21,600 BTU Lighting Load: 11,874 BTU Motor Load: 0 BTU Other Load: 0 BTU Total Misc. Load: 33,474 BTU Load Calculation Summary Total Design Load: 192,001.8 BTU Safety Factor: 10% Total Required Load: 211,201.9 BTU Quotes are valid for 30 Days. Due to ongoing product development. RapidSpec and its export documentation is subject to change without notice. In no event shall HTPG be liable for special or conseauential damages in connection with the use or output of RapidSpec. 17573CB SYS-1 - System Design Summary General Requirements ITEM #69 Room Temperature: 35 OF Ambient Temperature: 90 OF Design Run-time: 16 Hrs Required Capacity: 13,200 BTUH Selected Equipment Line Item Quantity Type Tag Description 1.0 1 System SYS-1 R-448A - Refrigeration Equipment Match 1 1.1 1 Condensing Unit CDU-1 RFO150E4SEA 1.2 1 Unit Cooler UC-1 RL6A117ADA System Balance Balanced Capacity: 12,736.2 BTUH Evap. T.D.: 9.4 °F Line Loss: 2 °F Suction Temp: 23.6 °F Calc. Run -Time: 16.6 Hrs Quotes are valid for 30 Days. Due to ongoing product development, RapidSpec and its export documentation is subject to change without notice. In no event shall HTPG be liable for special or consequential damages in connection with the use or output of RapidSpec. 17573CB SYS-1 - UC-1 - Product Information General Data ITEM #70 Model Line: NEXT-GEN ALL -TEMP Model Number: RL6A117ADA Motors: DUAL SPEED EC MOTOR Unit Voltage: 115/1/60 Defrost Type: AIR DEFROST Refrigerant: R-448A Fins Per Inch: 6 Number of Fans: 2 Performance Data Suction Temp: 25 °F T.D: 9.4 °F Capacity: 12,736.2 BTUH CFM: 1550 Electrical Data Motor Voltage: 115/1/60 Total Unit Fan Motor Amps: 1.6 Heater Voltage: 115/1/60 Heater Amps: 0 Heater Watts: 0 MCA: 15 MOPD: 20 Physical Data Liquid Line: 3/8 in. Suction Line: 518 in. Approx. Ship Weight: 58 Ibs Option Data Mounted Option EcoNet Control Package Manual Option WHITE HOUSING Compliance Data AWEF: 9.00 Notes Quotes are valid for 30 Days. Due to ongoing product development, RapidSpec and its export documentation is subject to change without notice. In no event shall HTPG be liable for special or consequential damages in connection with the use or output of RapidSpec. Submittal data shown represents design conditions. This quote contains options that were manually added. All manually added options will require review by HTPG prior to orders being accepted. Dimensional Drawing 16 (BACKSIDE) v ✓ Standard Features • Embossed aluminum housing • Enhanced copper tube and aluminum fin coil construction • Sweat connections • Thermal overload protection • High efficiency fan guard design and deep draw venturi • Heavy-duty fans are balanced for vibration -free operation Certifications ��pSSIFjFO C UL US 7/8 ELECTRICAL KNOCKOUTS (BACKSIDE) ITEM #70 ,AIR • Fan sections are baffled to prevent short cycling of air • Slide out end panels • Removable drain pan • Mounts flush to the ceiling • Top pan includes 1/2" wide slotted mounting points • UL/cUL certified for use with multiple refrigerants • NSF approved for use in food preparation areas 17573CB SYS-1 - CDU-1 - Product Information General Data ITEM #71 Model Line: NEXT-GEN MINI -CON Model Number: RFO150E4SEA Flooded: Yes Refrigerant: R-448A Voltage: 208-230/3160 Compressor Type: SCROLL Performance Data Ambient Temp: 90 °F Suction Temp: 23 °F Capacity: 12,088 BTUH Electrical Data Compressor RLA: 9.3 Compressor LRA: 58 Total Condenser Fan FLA: 1 MCA: 19.6 MOPD: 25 Physical Data Number of Compressors: 1 Compressor Model: ZS11 KAE Compressor HP: 1.5 Number of Condenser Fans: 2 Approx. Ship Weight: 205 Ibs Sound Data: 71 dBA Liquid Line: 1/2 in. Suction Line: 718 in. Pump Down Capacity (%): 90 Pump Down Capacity: 11.6 Ibs Option Data Mounted Option NO STANDARD AIR DEFROST TIMER Mounted Option LIQUID LINE WITH COMPONENTS: SEALED FILTER & SIGHT GLASS Mounted Option STANDARD RECEIVER Mounted Option FIXED HIGH/FIXED LOW PRESSURE CONTROL Compliance Data AWEF: 7.60 Notes Quotes are valid for 30 Days. Due to ongoing product development, RapidSpec and its export documentation is subject to change without notice. In no event shall HTPG be liable for special or consequential damages in connection with the use or output of RapidSpec. MCA/MOPD and Defrost Kit selection will be confirmed at time of purchase. Submittal data shown represents design conditions. Dimensional Drawing 28-1/4 LIQUII OUT 18 T T 24-3/16 Standard Features • All-weather Galvanized steel painted housing • Generously sized high efficiency condenser, enhanced copper tubes/aluminum fins • Integral Liquid Subcooling Circuit provides subcooled liquid to the expansion device • Crankcase heater • Large electrical panel with hinged/removable door • Color coded point-to-point wiring Certifications SI fle C @us ITEM #71 38-1/4 CONTROL PANEL - 7/8" KO (2) FOR ELECTRICAL CONNECTIONS 3/8" MOUNTING HOLES (4) 39-1/8 39-7/8 • Quick access to shut off valves from exterior • UL/cUL certified for use with multiple refrigerants • UL/cUL listed for outdoor use • Flooded models include flooded head pressure control • Non flooded models include mild ambient fan cycle control