Loading...
APPROVED PLN_BLD BLD2022-0463+Architectural_Plan+4.12.2022_3.57.30_PM+2798303STARK RES DENCE FOUNDATION REPAIR 133 SUNSET AVE N EDMONDS, WA 98020 OWNER SUSAN STARK 133 SUNSET AVE N EDMONDS, WA 98020 425.478.8892 CONTACT: JSUSANSTARK@GMAIL.COM CONSULTANTS STRUCTURAL ENGINEER CG ENGINEERING 250 4TH AVE S, SUITE 200 EDMONDS, WA 98020 425.778.8500 FAX 778.5536 CONTACT: DENNIS TITUS, PE, SE LEGAL DESCRIPTION EDMONDS PLAT OF BLK 013 D-00 - LOT 5 EXC ANY PTN THOF LY WITHIN BNRR R/W PARCEL NUMBER 00434401300500 PROPERTY INFORMATION TOTAL LOT AREA = 4,792 SQFT EX BUILDING FOOTPRINT = 1,910 SQFT PROPOSED BUILDING FOOTPRINT = NOT TO CHANGE TOTAL IMPERVIOUS SURFACE = NOT TO CHANGE SCOPE OF WORK STABILIZE EXISTING FOUNDATION WITH PIN PILES & HELICAL ANCHORS. NOTE: SITE PLAN HAS BEEN PREPARED BASED ON FIELD MEASUREMENTS & COUNTY RECORDS & IS NOT A SURVEY, PROPERTY LINES ARE APPROXIMATE. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS & UTILITY LOCATIONS. SOIL/GEOTECH ENGINEER ASSOCIATED EARTH SCIENCES, INC. 911 5TH AVE KIRKLAND, WA 98033 425.827.7701 CONTACT: STEPHEN A. SIEBERT, PE Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. SITE PLAN SCALE: 1" = V-0" AREA OF WORK. UNDERPIN EXISTING FOUNDATION W/ HELICAL ANCHORS OR PIN PILES APPROVED BY PLANNING 4714OL'" Jul 25 2022 VICINITY MAP NTS = PROJECT SITE 10 0 5 10 3a�1 m W Dayton St Dayton St �a s h JC 0 = 2 Daley St "' Fa 'ho�o's s� -an1es St t^ a Alder St Dayton St Rell St Q P P �a r r P Main St D m N Dayton St a D m N Maple St ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE Special Inspection progress reports provided by a qualified inspection firm shall be provided to the City. Helical Pile Installation Pin Pile Installation Epoxy Anchorage. City Of Edmonds Building Department Work FOUNDTION STABILIZATION Address 133 SUNSET AVE N Owner STARK ----------------------------- Approved Date ; 05/02/2022 ------------------- Building Official Erie CA�feir -------------------------------------------------= ----------------------------------------- . Permit Number; BLD2022-0453 O C I ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 04/08/22 N Ld --- I Q O C) It Y Q DESIGN: DMT DRAWN: LVW CHECK: DMT JOB NO: 22046.10 DATE: 04/08/22 RECEIVED Apr 18 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 Z o w w 00 0 ] O� w Q Q o �_ � z _W LJ Ul Z 0 N Z 0 W Q M M 0 � N N SHEET: STRUCTURAL NOTES O C (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. STRUCTURAL STEEL STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", LATEST EDITION. DESIGN LOADS WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, Fy = 50 KSI. DEAD LOADS: PLATES, ANGLES, CHANNELS, AND RODS SHALL CONFORM TO ASTM A36, Fy = 36 KSI. ROOF 15 PSF FLOOR 15 PSF STRUCTURAL TUBING SHALL CONFORM TO ASTM A500 GRADE B, Fy = 46 KSI. LIVE LOADS: STEEL PIPE SHALL CONFORM TO ASTM A53 GRADE B, Fy = 35 KSI. ROOF (SNOW LOAD) 25 PSF FLOOR 40 PSF BOLTS CONNECTING STEEL MEMBERS SHALL CONFORM TO ASTM A325-N. BOLTS SHALL BE 3/4"0 MINIMUM, LINO DECK 60 PSF ANCHOR BOLTS SHALL CONFORM TO ASTM A307. (LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.11). CONTRACTOR SHALL PROVIDE CONNECTION ADJUSTMENT TOLERANCES TO SATISFY THE REQUIREMENTS OF AISC MANUAL OF STEEL CONSTRUCTION. STATEMENT OF SPECIAL INSPECTIONS UNLESS SPECIFIED AS STAINLESS STEEL, ALL STEEL MEMBERS, SHAPES, BOLTS, AND ACCESSORIES EXPOSED TO SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A WEATHER SHALL BE HOT DIP GALVANIZED. WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF WORK IN ACCORDANCE WITH SECTION 1704.4 OF THE IBC. WELDING FREQUENCY AND DISTRIBUTION OF REPORTS - INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY WELDING SHALL CONFORM TO AWS "STRUCTURAL WELDING CODE", LATEST EDITION. ALL WELDING SHALL BE SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS DONE WITH 70 KSI LOW HYDROGEN ELECTRODES. WHERE NOT CALLED OUT, MINIMUM FILLET WELD SIZE SHALL BE SHALL BE DISTRIBUTED TO THE CONTRACTOR, ARCHITECT, ENGINEER AND BUILDING OFFICIAL. PER TABLE 5.8 IN AWS D1.1, LATEST EDITION. SPECIAL INSPECTION OPERATION CONT PERIODIC REMARKS SOILS PIPE PILING INSTALLATION X PILING REFUSAL VERIFICATION X EPDXY ANCHORS X HELICAL PILE INSTALLATION X NOTE: ALL ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17. SPECIAL INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL RESULTS. ANY INSPECTION FAILING TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE DESIGN TEAM. FOUNDATIONS: PIN PILES SOILS REPORT: REPORT NO: 20210191EO01 PREPARED BY: ASSOCIATED EARTH SCIENCES, INC. DATED: 11/02/2021 ALLOWABLE PILE CAPACITY: PASSIVE EARTH PRESSURE: LATERAL EARTH PRESSURE: UNRESTRAINED RESTRAINED: 10 TONS 200 PCF 35 PCF + ANY APPLICABLE SURCHARGE 35 PCF + 10 PSF * WALL HEIGHT IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12") INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM TEST METHOD D1557. BACKFILL BEHIND ALL RETAINING WALLS WITH WELL -DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. PROVIDE DAMPPROOFING AT EXTERIOR FACE OF ALL FOUNDATION WALLS EXPOSED TO EARTH PER ARCHITECTURAL SPECIFICATIONS. 2" 0 PIPE PILING INSTALLATION 2" XS PIPE SHALL CONFORM TO ASTM A53 GRADE A OR B, FY = 30 KSI (MIN) PILES SHALL BE DRIVEN THROUGH LOOSE MATERIAL & BEAR IN COMPETENT DENSE SOIL AS DETERMINED BY THE GEOTECHNICAL SPECIAL INSPECTOR. PILES SHALL HAVE A MINIMUM OVERALL EMBEDMENT OF 20 FEET OR AS DETERMINED ADEQUATE BY THE GEOTECHNICAL SPECIAL INSPECTOR. PILES SHALL NOT EXCEED A MAXIMUM EMBEDMENT DEPTH OF 30 FEET. PIPE PILING SHALL BE DRIVEN INTO THE SUBGRADE TO A POINT OF REFUSAL BY MEANS OF A PNEUMATIC HAMMER OR OTHER SIMILAR HYDRAULIC HAMMER SYSTEM. THE PNEUMATIC HAMMER SHOULD WEIGH AT LEAST 140 POUNDS. REFUSAL SHALL BE DEFINED AS 1" OR LESS OF PENETRATION DURING 1 MINUTE OF SUSTAINED DRIVING. PIPE SECTIONS SHALL BE CONNECTED WITH INTERNAL SLIP COUPLINGS. THE CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY ALL UTILITIES WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THESE DRAWINGS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY AND ALL DAMAGE TO UNDERGROUND UTILITIES RESULTING FROM THEIR OPERATION. ROUND SHAFT HELICAL ANCHOR INSTALLATION HELICAL ANCHORS SHAFT SHALL CONFORM TO ASTM A500 WITH MIN Fy = 65KS1. REFER TO ANCHOR SCHEDULE FOR MINIMUM SHAFT DIAMETER AND ANCHOR LOADING. ALL ANCHORS SHALL PENETRATE THROUGH THE LOOSE SOIL & EMBED INTO DENSE SOIL. THE DEPTH OF THE DENSE SOIL SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER. ANCHORS SHALL HAVE A MINIMUM EMBEDMENT DEPTH OF 8 FT BELOW BOTTOM OF FOOTING OR AS APPROVED BY THE GEOTECHNICAL SPECIAL INSPECTOR. THE ANCHOR INSTALLATION AND LOAD TESTING SHALL BE CONTINUOUSLY MONITORED BY THE GEOTECHNICAL ENGINEER. REFER TO THE ANCHOR LOADING SCHEDULE FOR ANCHOR CAPACITIES. ANCHOR CAPACITIES SHALL BE VERIFIED DURING INSTALLATION TO 200% OF THE ALLOWABLE CAPACITY. THE STRUCTURAL ENGINEER SHOULD BE CONTACTED IF THE ALLOWABLE PILE CAPACITY IS NOT ACHIEVED. ANCHORS SHALL BE COATED FOR CORROSION PROTECTION. COATING MAY BE HOT DIP GALVANIZED OR THERMAL PLASTIC COATING. A MINIMUM OF 3% OR AT LEAST (1) ANCHOR SHALL BE TESTED IN ACCORDANCE WITH ASTM STD D1143. WHERE ANCHORS HAVE MULTIPLE FLIGHTS OF HELICES THE HELICES SHALL BE SEPARATED BY A MINIMUM OF 3 HELIX DIAMETERS. WELDING OF REINFORCING BARS SHALL NOT BE PERMITTED UNLESS SPECIFICALLY CALLED OUT ON DRAWINGS OR APPROVED BY STRUCTURAL ENGINEER. WELDING OF GRADE 60 REINFORCING BARS SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS SHALL BE PERFORMED USING E70XX ELECTRODES. SEE REINFORCING NOTES FOR MATERIAL REQUIREMENTS OF WELDED BARS. WELDING WITHIN 4" OF COLD BENDS IN REINFORCING BARS IS NOT PERMITTED. ALL WELDING SHALL BE DONE BY WASHINGTON ASSOCIATION OF BUILDING OFFICIALS (WABO) CERTIFIED WELDERS. EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. GENERAL STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. LEGEND DEFINITION SYMBOL DEFINITION SYMBOL DIRECTION OF FRAMING pplp, NATIVE SOIL EXTENT OF FRAMING GRANULAR FILL STRUCTURAL STEEL COLUMNS COLUMN BEARING ON BEAM P RATED SHEATHING BEAM CONTINUOUS OVER SUPPORT d'b SHEAR WALL (SEE SCHEDULE) SWX CONCRETE WALL COLUMN MARK (SEE SCHEDULE) BEARING STUD WALL NON -BEARING STUD WALL BEARING STUD SHEAR WALL FOOTING MARK (SEE SCHEDULE) O O HOLDOWN MARK (SEE SCHEDULE) HANGER MARK (SEE SCHEDULE) NON -BEARING STUD SHEAR WALL 41 FLAG NOTE (SEE PLAN NOTES) CMU WALL�:Xxxxxx STEEL MOMENT FRAME CONN. �V ABBREVIATIONS (A) ABOVE ANCHOR BOLT HORIZ KIP HORIZONTAL KING POST AB ALT ALTERNATE KSI KIPS PER SQUARE INCH ARCH ARCHITECT MECH MECHANICAL (B) BELOW MF MOMENT FRAME BLKG BM BLOCKING BEAM INS NEAR SIDE ON CENTER OC BOT BOTTOM OPP OPPOSITE PLATE BTWN BETWEEN PL CJP COMPLETE JOINT PENETRATION PLCS PLACES POUNDS PER SQUARE INCH CLR CLEAR PSI CMU CONCRETE MASONRY UNIT PSF POUNDS PER SQUARE FOOT COL COLUMN P/T POST TENSIONED CONC CONCRETE PT PRESSURE TREATED CONN CONNECTION REINF REINFORCING CONT CONTINUOUS REQ'D REQUIRED SCHEDULE DBL DOUBLE SCHED DET DETAIL SIM SIMILAR SLAB ON GRADE DIM DIMENSION SOG EA EACH STD STANDARD SHEAR WALL ELEV ELEVATION SW EXIST EXISTING TOC TOP OF CONCRETE TOP OF STEEL EXP EXPANSION TOS FLR FLOOR FOUNDATION TOW TOP OF WALL FDN TYP TYPICAL FTG FOOTING FAR SIDE UNO UNLESS NOTED OTHERWISE FS VFY VERIFY FH FULL HEIGHT VIF VERIFY IN FIELD VERTICAL GLIB GLUE -LAMINATED BEAM VERT EXIST ����q�RE�LEV�ATI�ONS1 SCALE: 1/8 5'-0" 0 5'-0" 10'4" ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 0�/ 08/ 22 N Ld rq 00 Q O O Y Q' Q II DESIGN: DMT III II DRAWN: LVW III II CHECK: DMT II JOB NO: 22046.10 DATE: 04/08/22 \Q LIJ 0 w Z N 0 w w 00 0 0 ] O� J W Q � � 0 W oV Lj ul Z N F- =) 0 U () Y V) 0 � Ld Q M � W I— 0 II-- M 0 I-- V) W (n Z SHEET: Simi O C C F. LOWER LEVEL PLAN SCALE: 1/4" = V-0" PILE PLAN NOTES 1. CONTRACTOR SHALL VERIFY PILE LOCATIONS WITH EXISTING BUILDING CONDITIONS & APPROVED STRUCTURAL DRAWINGS. 2. ALL PILES, ANCHORS, & BRACKETS SHALL BE GALVANIZED. 3. PILE CONTRACTORS SHALL DISCUSS WITH OWNERS THEIR EXPECTATION FOR LIFTING THE STRUCTURE DURING BIDDING PROCESS. 4. VERTICAL PILES SHALL HAVE A MINIMUM EMBEDMENT OF 20 FT OR AS APPROVED BY THE GEOTECHNICAL SPECIAL INSPECTOR. 5. ALL PILES SHALL BE INSTALLED TO AN ULTIMATE LOAD OF 2 TIMES THE DESIGN LOAD. 6. ALL PILE INSTALLATIONS & LOAD TESTS SHALL BE OBSERVED BY THE GEOTECHNICAL SPECIAL INSPECTOR. 7. MINIMUM INSTALLATION TORQUE IS BASED ON KT VALUE PROVIDED. CONTRACTOR SHALL VERIFY KT & MAX TORQUE BASED ON THE MANUFACTURER'S RECOMMENDATIONS. PILE & ANCHOR SCHEDULE PILE TYPE DESIGN LOAD PILE SHAFT HELIX CONFIGURATION MIN INSTALL TORQUE MAX INSTALL TORQUE KT NOTES P1-P24 2" 0 PIN PILE 6.OK 2" STD PIPE - - - - - H1-H11 PIPE HELICAL PILE 14.01< 2 7/8" x 0.203" PIPE HELIX DOUBLE HELIX (8", 10") 3,100 FT# 5,500 FT# 9 LOCI< OFF SNUG TIGHT ONLY H12-H15 PIPE HELICAL PILE 13.0K 2 7/8" x 0.203" PIPE HELIX DOUBLE HELIX (8", 10") 2,800 FT# 5,500 FT# 9 LOCK OFF SNUG TIGHT ONLY H16-H20 PIPE HELICAL PILE 14.0K 2 7/8" x 0.203" PIPE HELIX DOUBLE HELIX (8", 10") 3,100 FT# 5,500 FT# 9 LOCI< OFF SNUG TIGHT ONLY NOTES: 1. CONTRACTOR SHALL VERIFY HELIX CONFIGURATION CAPABLE OF DEVELOPING THE DESIGN LOADS. 2. MIN INSTALL TORQUE ASSUMES Kt = 9.0 IF A PILE WITH A DIFFERENT Kt VALUE IS USED MIN INSTALL TORQUE SHALL BE ADJUSTED. 3. MIN INSTALL TORQUE INCLUDES A FACTOR OF SAFETY OF 2.0. 4. ALL PILES SHALL INSTALLED TO TWICE THE DESIGN LOAD. 2'-0" 0 2'-0" 3 4'-0" ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 04/08/22 N Ld rq 00 Q O O Y 0' Q DESIGN: DMT DRAWN: LVW CHECK: DMT JOB NO: 22046.10 DATE: 04/08/22 0 Z 0 Ld LLI 00 U ] O� Ld < N Ld LLJ (n Z a (/) 0 Y N 0 Q M � H M 0 (n LLJ SHEET: (n Ld F- 0 Z J Q D F— U D w F— (n S2ml O C I EXIST FOUNDATION CHIP OUT PORTION OF FTG TO INSTALL ANGLE DIRECTLY BENEATH STEM WALL 1/2"0 THREADED ROD W/ 4" MIN EMBED INTO FTG W/ HILTI HIT HY 200 INJECTION ADHESIVE. ALTERNATELY 1/2" 0 EXPANSION ANCHORS MAY BE USED W/ 4" MIN EMBED — L6x6x3/4x12"LONG TYPICAL DETAIL SCALE: 1 1/2" = V-0" CONSTRUCTION SEQUENCE NOTES: 1. JACK EXISTING STRUCTURE FROM PILE AFTER REFUSAL IS COMPLETED & CRITERIA MET. 2. TIGHTEN NUTS AFTER PORTION OF HOUSE LEVELED. 3. REMOVE JACK & TOP PL & REMOVE EXCESS THREADED ROD. JACK NOT SHOWN FOR CLARITY PL 1 x 4 x 0'-9" W/ 15/16" 0 I I HOLES TO ALIGN W/ 1" ES I I PIPE BELOW, TYP I I \ I I 7/8"0 THREADED ROD \ I 1" EXTRA STRENGTH I I PIPE x 4" LONG I I 2 I I I I I I I I I I I I TS5 x 3 x 1/4 x 8" LONG I I I I Ir PIPE PILE PER PLAN I I I I I I I I NOTE: TOP PL & THREADED ROD NOT SHOWN FOR CLARITY EXIST FOUNDATION 5/8" 0 LONG SLOTTED HOLES 1" EXTRA STRENGTH PIPE x 4" LONG, TYP TS5 x 3 x 1/4 x 8" LONG I I I I _ I � I � I � I I PIPE PILE PER PLAN 1/4 /TYP 1/4 �\ L6 x 6 x 3/4 x 12" LONG TYPICAL DETAIL SCALE: 1 1/2" = V-0" EXISTING GRADE SECTION SCALE: 1" = V-0" REPLACE EXIST SLAB ON GRADE AS REQ'D Duo- oo O"ov o0 CR O.° 00 A O.° 00 77— I' ® 'ilI,I- I I I I I I NOTE: FOR INFORMATION NOT I I SPECIFICALLY CALLED OUT REFER TO DETAIL 1 fl EXIST DECK FRAMIN SIMPSON ABU POST BA5 W/ EXPANSION ANCHO PVC SLEEV 3/4" 0 THREADED RO PL1/2x6x0'-E (2) #4 EA WAY BO CAP PL 1/4 x 4 x 0'-z PIPE PILE PER PLA SECTION SCALE: 1" = V-0" -OUNDATION -vv LL �; EPDXY INTO EXIST FTG W/ SIMPSON SET-XP & 4" MIN EMBED ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 04/08/22 1 J z O CY U � (n � W w N W Q O O Y Q DESIGN: DMT DRAWN: LVW CHECK: DMT JOB NO: 22046.10 DATE: 04/08/22 0 Z 0 LL11 LLI 00 U ] O� w Q Q N w w N z N 0 o Q M � H M 0 N W SHEET: S3ml