APPROVED BLD RESUB 1-Structural Plans-12.14.2022_9.54.49_AM+3268235@ - AT Ø, DIA - DIAMETER (E), EXIST - EXISTING #, NO - NUMBER ADDL - ADDITIONAL APPROX - APPROXIMATE ARCH - ARCHITECTURAL BLKG - BLOCKING BM(S)- BEAM(S) BO XXX - BOTTOM OF XXX BOF - BOTTOM OF FOOTING BRG - BEARING BTWN - BETWEEN CLR - CLEAR(ANCE) CONC - CONCRETE CTR - CENTER(ED) DBL - DOUBLE DEMO - DEMOLITION DIAG - DIAGONAL/DIAGRAM DIM - DIMENSION DIST - DISTANCE EA - EACH EMBED - EMBEDMENT/EMBEDDED EQ - EQUAL FT - FOOT, FEET FTG - FOOTING GALV - GALVANIZED GLB - GLUE LAMINATED TIMBER HDR - HEADER HGR - HANGER HLDN - HOLDOWN HORIZ - HORIZONTAL IN - INCHES JST - JOIST JT - JOINT LBR - LUMBER LOC - LOCATION MAX - MAXIMUM MID - MIDDLE MIN - MINIMUM MISC - MISCELLANEOUS N/A - NOT APPLICABLE NTS - NOT TO SCALE OC - ON CENTER OPNG - OPENING OPP - OPPOSITE PL - PLATE PREFAB - PREFABRICATED PT - PRESSURE TREATED REINF - REINFORCING REQD - REQUIRED SCHED - SCHEDULE SHTHG - SHEATHING SIM - SIMILAR STRUCT - STRUCTURAL TO XXX - TOP OF XXX TOSL - TOP OF SLAB TOW - TOP OF WALL TYP - TYPICAL T&B - TOP AND BOTTOM T&G - TONGUE AND GROOVE UON - UNLESS OTHERWISE NOTED VIF - VERIFY IN FIELD VERT - VERTICAL WWF - WELDED WIRE FABRIC W/- WITH W/O - WITHOUT ABBREVIATIONS BUILDING CODE 1.ALL CONSTRUCTION, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THESE DRAWINGS, SPECIFICATIONS, AND THE CODES, RULES AND REGULATIONS OF THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION, AS ADOPTED AND AMENDED BY CITY OF EDMONDS, WASHINGTON, HEREINAFTER REFERRED TO AS THE BUILDING CODE. 2.WHERE NOTED IN THE STRUCTURAL NOTES, CONSTRUCTION, MATERIALS, AND WORKMANSHIP SHALL ALSO CONFORM TO THE FOLLOWING STANDARDS. WHERE THESE STANDARDS CONFLICT WITH THE BUILDING CODE, THE CODE SHALL GOVERN. GENERAL ASCE7 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES" ASCE/SEI 7 - 2016 EDITION CONCRETE ACI-318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" ACI 318 - 2014 EDITION ACI-301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE" ACI 301 - 2010 EDITION ACI-315 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" ACI 315 - 2017 EDITION WOOD NDS "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION" ANSI/AWC NDS - 2018 EDITION SDPWS "SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC" AWC SDPWS - 2015 EDITION TPI 1 "NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION" ANSI/TPI 1 - 2014 EDITION STEEL AISC-360 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" ANSI/AISC 360 - 2016 EDITION DESIGN CRITERIA 1.DEAD LOAD CRITERIA WOOD ROOF 14 PSF WOOD FLOORS 12 PSF EXTERIOR WALLS 10 PSF 2.LIVE LOAD CRITERIA ROOF LIVE LOAD 20 PSF (REDUCIBLE) RESIDENTIAL FLOOR 40 PSF (REDUCIBLE) 3.SNOW DESIGN CRITERIA MINIMUM ROOF SNOW LOAD 25 PSF 4.WIND DESIGN CRITERIA 3-SECOND GUST WIND SPEED, V =100 MPH EXPOSURE FACTOR B IMPORTANCE FACTOR I =1.00 TOPOGRAPHIC FACTOR Kzt = 1.00 5.SEISMIC DESIGN CRITERIA SEISMIC USE GROUP II SITE CLASS D IMPORTANCE FACTOR I =1.00 SS =1.319 S1 =0.468 SDS =1.056 SD1 =0.583 SEISMIC DESIGN CATEGORY D SEISMIC FORCE RESISTING SYSTEM: LIGHT-FRAMED WOOD SHEAR WALLS RESPONSE MODIFICATION FACTOR, R =6.5 DEFLECTION AMPLIFICATION FACTOR, Cd =4.0 EQUIVALENT LATERAL FORCE PROCEDURE USED 6.FOUNDATION DESIGN CRITERIA SOIL PROFILE TYPE = SITE CLASS D FOUNDATION TYPE =SPREAD AND STRIP FOOTINGS ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF PASSIVE EARTH PRESSURE = 100 PCF COHESION =130 PSF NO SOILS REPORT AVAILABLE. BASED UPON THE PRESUMPTIVE SOIL VALUES PER IBC TABLE 1806.2 GENERAL NOTES 1.THE STRUCTURAL DRAWINGS REPRESENT THE DESIGN OF THE PRIMARY STRUCTURE BASED ON PRESCRIBED LOADS, (SEE "DESIGN CRITERIA" SECTION), IMPOSED ON THE STRUCTURE PER THE BUILDING CODE AS SPECIFIED IN THE "BUILDING CODE" SECTION. THE PRIMARY STRUCTURE OF THE BUILDING IS DEFINED AS THE FOUNDATIONS, BEARING WALLS, SHEAR WALLS, COLUMNS, BEAMS, SLABS, FLOOR AND ROOF FRAMING AND LATERAL FORCE RESISTING ELEMENTS REQUIRED TO MAINTAIN THE STABILITY OF THE COMPLETED STRUCTURE AS A WHOLE. 2.ALL CONSTRUCTION MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE DRAWINGS, SPECIFICATIONS, AND THE CODES, RULES AND REGULATIONS OF THE BUILDING CODE AS DEFINED IN THE "BUILDING CODE" SECTION. CONSTRUCTION TOLERANCES SHALL CONFORM TO THE BUILDING STANDARDS SPECIFIED IN THE "BUILDING CODE" SECTION. 3.THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS. 4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY BRACING AS REQUIRED FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL MEMBERS ARE IN PLACE AND FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. 6.DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES PRIOR TO CONSTRUCTION. 7.FRAMING MEMBERS WHICH ARE NOT DIMENSIONED SHALL BE EQUALLY SPACED BETWEEN DIMENSIONED POINT OF MEMBERS. 8.IF ANY ERRORS OR OMISSIONS APPEAR TO EXIST IN THESE DRAWINGS, SPECIFICATIONS, OR OTHER CONTRACT DOCUMENTS; THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OR ARCHITECT IN WRITING OF SUCH OMISSION OR ERROR BEFORE PROCEEDING WITH THE WORK. 9.NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NOTES AND DETAILS ON DRAWINGS AND THESE GENERAL NOTES AND TYPICAL DETAILS ARE IN CONFLICT THE MOST STRINGENT SHALL APPLY. CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE CONSTRUCTED AS SHOWN FOR SIMILAR WORK, SUBJECT TO REVIEW BY THE STRUCTURAL ENGINEER. 10.CONTRACTOR SHALL COORDINATE THE STRUCTURAL DRAWINGS WITH DRAWINGS FROM ALL OTHER DISCIPLINES, INCLUDING BUT LIMITED TO ARCHITECTURAL, CIVIL, MECHANICAL AND ELECTRICAL. 11.SEE ARCHITECTURAL DRAWINGS FOR THE FOLLOWING: A.SIZE AND LOCATION OF ALL DOOR AND WINDOW OPENINGS. B.SIZE AND LOCATION OF ROOF AND FLOOR OPENINGS. C.SIZE AND LOCATION OF ALL NON-BEARING PARTITIONS. D.EXTERIOR WALL SYSTEMS.AND FINISH REQUIREMENTS E.DIMENSIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS. 12.ALL MATERIALS SHALL BE DELIVERED, STORED AND HANDLED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS. PROTECT ALL ITEMS FROM DAMAGE, MOISTURE, CORROSION, OR DETERIORATION BEFORE, DURING AND AFTER INSTALLATION. SUBMITTALS CONT. 3."SHOP DWGS" - SUBMIT COMPLETE SHOP DRAWINGS SUFFICIENT TO SHOW QUANTITIES AND KINDS OF MATERIALS, METHODS OF ASSEMBLY, AND ALL DATA REQUIRED FOR FABRICATION, ERECTION, AND INSTALLATION. IF DEVIATIONS, DISCREPANCIES OR CONFLICTS BETWEEN SHOP DRAWING SUBMITTALS AND THE CONTRACT DOCUMENTS ARE DISCOVERED, EITHER PRIOR TO OR AFTER REVIEW BY THE STRUCTURAL ENGINEER, THE DESIGN DRAWINGS SHALL CONTROL AND SHALL BE FOLLOWED. RESPONSIBILITY FOR ADHERENCE TO THE CONTRACT DOCUMENTS LIES SOLELY WITH THE CONTRACTOR. DIMENSIONS AND QUANTITIES ARE NOT REVIEWED BY THE STRUCTURAL ENGINEER AND THEREFORE MUST BE VERIFIED BY THE CONTRACTOR. 4."CALCS" - SUBMIT SIGNED AND SEALED CALCULATIONS PREPARED BY A DESIGN PROFESSIONAL AUTHORIZED TO PERFORM WORK IN THE PROJECT JURISDICTION. CALCULATIONS SHALL INDICATE THE MAGNITUDE AND DIRECTION OF ALL LOADS IMPOSED ON THE BASIC STRUCTURE. THE 5.THE CONTRACTOR SHALL REVIEW, STAMP AND APPROVE SUBMITTALS PRIOR TO REVIEW BY THE STRUCTURAL ENGINEER. UNREVIEWED OR UNSTAMPED SUBMITTALS WILL BE RETURNED TO THE CONTRACTOR UNREVIEWED. 6.COMMENTS OR MARKS ON SUBMITTALS ARE A NORMAL AND EXPECTED PART OF THE SUBMITTAL PROCESS AND SHALL NOT BE USED AS A BASIS FOR CHANGE ORDERS. TIME REQUIRED TO REVISE AND RESUBMIT ANY SUBMITTAL SHALL BE CONSIDERED INHERENT TO THE SUBMITTAL REVIEW PROCESS AND SHALL NOT BE DEEMED A CHANGE ORDER. 7.RESUBMITTALS SHALL HAVE ALL REVISIONS CLEARLY IDENTIFIED WITH DRAWING CLOUDS AND REVISION DATES. THE STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR THE REVIEW OF ANY UNMARKED REVISIONS. SUBSTITUTIONS 1.CONTRACTOR REQUESTED CHANGES OR SUBSTITUTIONS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. A CURRENT ICC-ES REPORT AND A LIST STATING THE ITEM-FOR-ITEM SUBSTITUTION MUST BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR ANY PROPOSED SUBSTITUTIONS. THE CONTRACTOR WILL BE RESPONSIBLE FOR ANY ADDITIONAL ENGINEERING EFFORT AND ASSOCIATED FEES REQUIRED FOR REVIEW AND APPROVAL OF REQUESTED CHANGES AND SUBSTITUTIONS. FOUNDATIONS 1.SUBGRADE PREPARATION INCLUDING, DRAINAGE, EXCAVATION, COMPACTION, AND FILLING REQUIREMENTS SHALL CONFORM STRICTLY WITH THE RECOMMENDATIONS GIVEN IN THE SOILS REPORT OR AS DIRECTED BY THE GEOTECHNICAL ENGINEER. 2.ALL FOUNDATIONS SHALL BE FOUNDED A MINIMUM OF 18 INCHES BELOW LOWEST ADJACENT FINAL FINISH FLOOR OR GRADE. FOOTING DEPTHS ARE MINIMUM DIMENSIONS, AND MAY BE CHANGED BY THE SOILS ENGINEER IN ORDER TO ACHIEVE THE REQUIREMENTS OF THE APPROVED SOILS REPORT. EXPOSED SOIL SHALL BE INSPECTED FOR COMPLIANCE WITH THE SOILS REPORT PRIOR TO PLACING REINFORCING STEEL. 3.ALL RETAINING WALLS SHALL HAVE FREE DRAINING OR GRAVELY BACKFILL AT LEAST 24 INCHES THICK, OR DRAINAGE MATTING, FULL HEIGHT OF WALL. PROVIDE SUBSURFACE DRAINAGE AT THE BASE OF ALL RETAINING WALLS. BACKFILL SHALL NOT BE PLACED FOR AT LEAST 7 DAYS AFTER THE CONCRETE POUR. SPECIAL INSPECTION 1.SPECIAL INSPECTION BY A REGISTERED DEPUTY BUILDING INSPECTOR, IN CONTRACT WITH THE OWNER AND APPROVED BY THE ARCHITECT AND THE BUILDING OFFICIAL, SHALL BE REQUIRED FOR THE FOLLOWING TYPES OF WORK: ITEM BUILDING CODE REFERENCE STEEL 1705.2 AND AISC 360 CHAPTER N DETAIL VERIFICATION WELDING OF STRUCTURAL STEEL CONCRETE 1705.3 SPECIFIED f'c GREATER THAN 2500 PSI PLACING OF REINFORCING STEEL SOIL 1705.6 PREPARED BEARING SURFACES SOIL COMPACTION SPECIAL SYSTEMS 1705.1.1 EXPANSION/EPOXY ANCHOR BOLTS 2.SPECIAL INSPECTIONS SHALL NOT BE REQUIRED WHEN THE WORK IS DONE ON THE PREMISES OF A FABRICATOR REGISTERED AND APPROVED BY THE BUILDING OFFICIAL TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION. CERTIFICATES OF COMPLIANCE SHALL BE SUBMITTED TO THE BUILDING OFFICIAL FROM THE FABRICATORS OR MANUFACTURERS OF THE FOLLOWING COMPONENTS: PREFABRICATED WOOD JOISTS PREFABRICATED WOOD TRUSSES 3.SUMMARY REPORTS OF ALL INSPECTIONS AND TEST RESULTS SHALL BE DISTRIBUTED TO THE OWNER, ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL WITH DEFICIENCIES CLEARLY NOTED. 4.DEFICIENCIES SHALL BE REPORTED TO THE CONTRACTOR ON A DAILY BASIS. CONCRETE 1.ALL CONCRETE CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE BUILDING CODE AND ACI SPECIFICATIONS. 2.CONCRETE SHALL CONFORM TO THE STRENGTH, WATER-CEMENT RATIO, EXPOSURE CLASS, MAXIMUM UNIT WEIGHT AND CEMENT TYPE SPECIFIED IN THE SCHEDULE BELOW. CONCRETE STRENGTHS SHALL BE VERIFIED BY 28-DAY CYLINDER TESTS. STRENGTH MAX WATER/EXPOSURE AIR ELEMENT f'c (PSI) CEMENT RATIO CLASS CONTENT FOOTINGS 2,500 0.50 C0, F0, S0, W0 - WALLS 3,500 0.55 C1, F1, S0, W1 5% A.PORTLAND CEMENT SHALL CONFORM TO ASTM C-150. B.COARSE AND FINE AGGREGATE SHALL CONFORM TO ASTM C-33. C.WATER SHALL BE CLEAR AND SHALL CONFORM TO ASTM C-1602. D.CONCRETE MIXING OPERATIONS SHALL CONFORM TO ASTM C-94. E.AIR ENTRAINMENT SHALL CONFORM TO ASTM C-260. 3.CONTRACTOR MAY USE AN ADMIXTURE SYSTEM TO PRODUCE FLOWABLE CONCRETE. MAXIMUM SLUMP SHALL NOT EXCEED 8 INCHES MEASURED AT THE PUMP. 4.THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMENT PLACED IN CAST-IN-PLACE CONCRETE: A.CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH:3" B.CONCRETE EXPOSED TO EARTH OR WEATHER: #6 THROUGH #18 BARS 2" #5 BAR, W31 OR D31 WIRE, AND SMALLER 1 1/2" C.CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:3/4" 5.PLACEMENT OF CONCRETE SHALL CONFORM TO ACI REQUIREMENTS AND THE CONTRACT DOCUMENTS. HARDENED CONCRETE SHALL BE ROUGHENED TO 1/4" AMPLITUDE AND A CONCRETE BONDING AGENT SHALL BE USED AT ALL LOCATIONS WHERE NEW CONCRETE WILL BE PLACED AGAINST HARDENED CONCRETE, UNLESS OTHERWISE NOTED. BONDING AGENT SHALL BE PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS, INCLUDING PREPARATION OF EXISTING SURFACES. 6.SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL VENTS AND DOOR AND WINDOW OPENINGS IN CONCRETE WALLS. REINFORCING SHALL NOT BE CUT. CORING OF CONCRETE IS NOT PERMITTED UNLESS APPROVED BY THE STRUCTURAL ENGINEER. 7.OBSERVE ALL ACI RECOMMENDATIONS FOR HOT OR COLD WEATHER CONCRETING. 8.TESTING CYLINDERS SHALL BE CAST AND TESTED BY QUALIFIED PERSONNEL IN ACCORDANCE WITH ACI 318, SECTION 26.12. 9.GROUT SHALL BE NON-SHRINK TYPE CONFORMING TO ASTM C-1107 WITH A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 7000 PSI. 10.CONTRACTOR SHALL COMPLY WITH OSHA REGULATION 29 CFR PART 1926, SUBPART Z - TOXIC AND HAZARDOUS SUBSTANCES, SECTION 1926.1153, PUBLISHED SEPTEMBER 1, 2016. CONSTRUCTION ACTIVITIES SUCH AS CUTTING, GRINDING, DRILLING OR CRUSHING CONCRETE OR MASONRY CAN CREATE DUST WITH RESPIRABLE CRYSTALLINE SILICA PARTICLES. CONTRACTOR SHALL LIMIT WORKER EXPOSURE TO RESPIRABLE CRYSTALLINE SILICA OR PROVIDE RESPIRATORY PROTECTION AS REQUIRED PER SECTION 1926.1153. REINFORCING STEEL 1.REINFORCING STEEL SHALL BE DETAILED, INCLUDING HOOKS AND BENDS, AND PLACED IN ACCORDANCE WITH ACI 315 AND ACI 318. 2.REINFORCING STEEL SHALL CONFORM TO ASTM A-615, GRADE 60. 3.WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-1064. 4.ALL REINFORCING BAR BENDS SHALL BE MADE COLD. BARS SHALL NOT BE RE-BENT. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT. 5.LAP ALL CONTINUOUS REINFORCEMENT (#6 AND SMALLER) 48 BAR DIAMETERS OR 2'-0" MINIMUM. LAPS OF LARGER BARS SHALL BE MADE IN ACCORDANCE WITH ACI 318, CLASS B SPLICE. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. 6.WELDED WIRE FABRIC SHALL BE LAPPED AT SPLICES SUCH THAT A MINIMUM OF THREE WIRES PARALLEL TO THE SPLICE ARE OVERLAPPED. SPLICES SHALL OVERLAP A MINIMUM OF 8 INCHES. 7.DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND SPACING AS THE VERTICAL REINFORCING, RESPECTIVELY, UNLESS OTHERWISE NOTED. 8.PROVIDE #4 x 2'-0" DIAGONAL BAR AT ALL REENTRANT CORNERS OF CONCRETE SLABS ON GRADE. 9.REINFORCEMENT SHALL BE SECURELY TIED IN PLACE PRIOR TO THE PLACEMENT OF CONCRETE OR GROUT. CONCRETE REINFORCEMENT SHALL BE SECURED IN CONFORMANCE WITH ACI-318 SECTION 26.6.2. POST INSTALLED ANCHORAGE 1.ADHESIVE ANCHORAGES, WHERE SPECIFIED ON THE DRAWINGS, SHALL CONFORM TO THE FOLLOWING: A.CONCRETE EPOXY ANCHORS:HILTI HIT-RE 500 V3 ESR-3814 SIMPSON SET XP ESR-2508 2.MECHANICAL ANCHORAGES, WHERE SPECIFIED ON THE DRAWINGS, SHALL CONFORM TO THE FOLLOWING: A.CONCRETE EXPANSION ANCHORS:HILTI KWIK BOLT TZ ESR-1917 SIMPSON SB 2 ESR-3037 B.CONCRETE SCREWS HILTI HUS-EZ ESR-3027 SIMPSON TITEN HD ESR-2713 3.ALL POST-INSTALLED ANCHORS SHALL BE INSTALLED IN STRICT CONFORMANCE WITH THE APPLICABLE ICC-ES REPORT, THE MANUFACTURER'S INSTRUCTIONS AND MINIMUM EMBEDMENT REQUIREMENTS. 4.ALL ANCHOR EMBED DEPTHS SPECIFIED ON THESE DRAWINGS ARE EFFECTIVE EMBEDMENT DEPTHS. ADDITIONAL ANCHOR LENGTH AND OR HOLE DEPTH SHALL BE PROVIDED AS REQUIRED BY THE ANCHOR MANUFACTURER. 5.ALL ANCHORS USED IN EXTERIOR APPLICATIONS, SUBJECTED TO MOISTURE, OR IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE HOT DIPPED GALVANIZED PER ASTM A153 OR STAINLESS STEEL, INCLUDING MATCHING NUTS AND WASHERS. STRUCTURAL STEEL, MISC. METAL 1.STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO THE BUILDING CODE AND AISC STANDARDS USING LOADS AS DEFINED IN AISC-360 SECTION B3-3 "DESIGN FOR STRENGTH USING LOAD AND RESISTANCE FACTOR DESIGN (LRFD)". 2.STRUCTURAL STEEL FABRICATION, ERECTION AND DIMENSIONAL TOLERANCES OF STRUCTURAL STEEL MEMBERS SHALL CONFORM TO AISC 303 REQUIREMENTS AND THE PROJECT SPECIFICATIONS. 3.STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING, UNLESS OTHERWISE NOTED ON THE STRUCTURAL DRAWINGS: A.WIDE FLANGE SHAPES ASTM A992, Fy = 50 KSI B.PLATES AND BARS ASTM A36, Fy = 36 KSI C.HOLLOW RECTANGULAR SECTIONS ASTM A500-B, Fy = 46 KSI D.ANCHOR RODS EMBEDDED IN CONCRETE ASTM F1554 GRADE 36 E.CONNECTION BOLTS A307 4.THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO THE START OF FABRICATION. 5.WELDING SHALL BE PERFORMED IN ACCORDANCE WITH AWS REQUIREMENTS. ALL WELDS SHALL BE PREQUALIFIED IN ACCORDANCE WITH AWS AND AISC STANDARDS. USE E70XX ELECTRODES, UON. 6.ALL WELDS SHALL BE PERFORMED BY WELDERS CERTIFIED IN THE JURISDICTION HAVING AUTHORITY OVER THIS PORTION OF THE WORK. 7.ALL BOLTS SHALL BE INSTALLED SNUG-TIGHT UNLESS OTHERWISE NOTED. 8.BOLT HOLES IN STEEL SHALL BE 1/16" LARGER THAN THE BOLT DIAMETER, UON. WOOD 1.LUMBER AND MANUFACTURED WOOD PRODUCTS SHALL CONFORM TO THE REQUIREMENTS OF THE BUILDING CODE AND NDS SPECIFICATIONS. 2.ALL FRAMING LUMBER SHALL BE KILN DRIED TO A MAXIMUM MOISTURE CONTENT OF 19 PERCENT AND GRADED AND MARKED IN CONFORMANCE WITH WCLB STANDARD GRADING AND DRESSING RULES FOR WEST COAST LUMBER NO. 17, LATEST EDITION. 3.LUMBER SHALL BE SPECIES AND GRADES AS FOLLOWS, UON: A.JOISTS: HF NO. 2 B.BEAMS:HF NO. 1 C.POST AND TIMBERS:HF NO. 1 D.PLATES, LEDGERS AND MISC LIGHT FRAMING:HF NO. 2 E.STUDS:HF NO. 2 4.ENGINEERED LUMBER: A. EACH PIECE SHALL BEAR A STAMP NOTING THE NAME AND PLANT NUMBER OF THE MANUFACTURER, THE GRADE, THE ICC-ES REPORT NUMBER AND THE QUALITY CONTROL AGENCY. ALL MEMBERS SHALL BE FABRICATED WITH AN APPROVED ADHESIVE AND MEET THE FOLLOWING MINIMUM DESIGN PROPERTIES: B.LAMINATED STRAND LUMBER (LSL) E = 1300 KSI, Fb = 1700 PSI, Fv = 400 PSI C.PARALLEL STRAND LUMBER (PSL) BEAMS: E = 2000 KSI, Fb = 2900 PSI, Fv = 290 PSI D. DESIGN SHOWN ON THESE DRAWINGS IS BASED ON LUMBER MANUFACTURED BY TRUS-JOIST WEYERHAEUSER IN ACCORDANCE WITH ICC ESR-1387. ALTERNATE ENGINEERED LUMBER MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER. ENGINEERED WOOD I-JOISTS 1.PREFABRICATED WOOD JOISTS SHALL BE DESIGNED BY THE MANUFACTURER FOR THE SPANS AND CONDITIONS SHOWN ON THE PLANS AND SHALL BE FURNISHED AND INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S PUBLISHED SPECIFICATIONS. 2.DESIGN LOADS SHALL BE AS FOLLOWS, UNLESS OTHERWISE NOTED: LIVE LOAD = SEE DESIGN CRITERIA DEAD LOAD = 12 PSF 3.DESIGN SHOWN ON THESE DRAWINGS IS BASED ON JOISTS MANUFACTURED BY TRUS-JOIST WEYERHAEUSER IN ACCORDANCE WITH ICC ESR-1153. ALTERNATE ENGINEERED WOOD I-JOISTS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER. 4.SUBMIT SHOP DRAWINGS AND DESIGN CALCULATIONS, SHOWING LAYOUT, DIMENSIONS, DETAILS AND REQUIRED BRACING TO THE STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION. 5.THE JOIST MANUFACTURER SHALL COORDINATE LOCATIONS AND SUPPORT CONFIGURATIONS OF PLUMBING, DUCTS AND OTHER MISC ITEMS WITH THE CONTRACTOR PRIOR TO JOIST FABRICATION. 6.ALL NECESSARY BRIDGING, BLOCKING, BLOCKING PANELS, STIFFENERS, BRACING, ETC., SHALL BE DETAILED AND FURNISHED BY THE MANUFACTURER. PERMANENT AND TEMPORARY BRIDGING SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 7.ALL JOIST HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH THE ENGINEERED WOOD I-JOISTS PROVIDED. ALL I-JOIST HANGERS SHALL BE "IUS" OR "ITS" SERIES, UON. SUBMITTALS 1.THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL PRIOR TO FABRICATION/ ERECTION/ INSTALLATION. 2."PROD DATA" - SUBMIT ADEQUATE DOCUMENTATION THAT THE PRODUCT PROPOSED TO BE USED MEETS THE REQUIREMENTS ON THESE PLANS. STRUCTURAL SUBMITTALS ITEM PROD DATA SHOP DWGS CALCS CONCRETE MATERIALS YES -- REINFORCING STEEL YES YES - PREFABRICATED WOOD TRUSSES YES YES YES PREFABRICATED WOOD JOISTS YES YES YES ENGINEERED LUMBER YES YES - GLUED LAMINATED MEMBERS YES YES - WOOD CONT. 5.GLUED LAMINATED MEMBERS: A.ALL GLUED LAMINATED MEMBERS SHALL BE FABRICATED IN ACCORDANCE WITH AITC 110, AITC 117 AND ANSI/AITC A190.1. EACH MEMBER SHALL BEAR AN AITC IDENTIFICATION MARK AND SHALL BE ACCOMPANIED BY AN AITC CERTIFICATE OF CONFORMANCE. B.BEAMS SHALL BE COMBINATION 24F-V4 OR 24F-V8 AS NOTED ON THE DRAWINGS: E = 1800 KSI, Fb=2400 PSI, Fv = 265 PSI C.CAMBER ALL GLU-LAM BEAMS TO 3,500-FOOT RADIUS, UON. D.USE EXTERIOR TYPE ADHESIVES. E.GLUED LAMINATED MEMBERS EXPOSED TO WEATHER OR MOISTURE SHALL BE TREATED WITH A NON-CORROSIVE, APPROVED PRESERVATIVE. F.BEAMS SHALL BE INDUSTRIAL APPEARANCE GRADE, UON. REV DATE DESCRIPTION PROJ. NO. DRAWN CHECKED DATE SHEET OF COFFMAN ENGINEERS INC.C 221651 07/01/2022 SHEET TITLE: SHEET NO: 1 A B C D A B C D 1 2 3 4 5 2 3 4 5 BINGHAM ADDITION 1711 69TH PL W, EDMONDS, WA 98026 PERMIT SET 6P: \ S E A \ 2 2 J O B S \ 2 2 1 6 5 1 B I N G H A M R E S I D E N C E \ 0 . 0 D W G S \ S \ 2 2 1 6 5 1 S _ S 0 . 1 . D W G .S0 . 1 : NE Y , B R E N N A N : L A S T S A V E D : Ju l y 1 , 2 0 2 2 : P L O T D A T E : 7/ 1 / 2 2 7/1/2022 www.coffman.com ph 360.707.5656 135 W Fairhaven Ave., Suite 102 Burlington, WA 98233 BJW RLR STRUCTURAL ABBREVIATIONS AND NOTES 1 S0.1 RESUB Dec 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-0898 The following documentation shall be available on site for the building inspector: COE APPROVED ARCHITECTURAL PLAN SET COE APPROVED STRUCTURAL PLAN SET COE REVIEWED CALCULATION PACKET ENERGY CREDIT WORKSHEET SITE PLAN CIVIL PLAN CITY OF EDMONDS BUILDING DEPARTMENT 2021 X APPROVED PLANS MUST BE ON JOB SITE WOOD FRAMING CONT. WOOD PROTECTION 1.ALL WOOD PLATES AND BLOCKING IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE TREATED IN ACCORDANCE WITH AWPA STANDARD U-1 TO THE REQUIREMENTS OF USE CATEGORY 2 (UC2). INSTALL (2) LAYERS OF ASPHALT-IMPREGNATED BUILDING PAPER BETWEEN UNTREATED LUMBER AND CONCRETE OR MASONRY. 2.ALL FRAMING WHICH WILL BE EXPOSED TO WEATHER OR MOISTURE SHALL BE TREATED IN ACCORDANCE WITH AWPA STANDARD U-1 TO THE REQUIREMENTS OF USE CATEGORY 3 (UC3). 3.FIELD TREAT ALL CUTS, END AND HOLES IN PRESSURE TREATED LUMBER WITH COPPER NAPHTHENATE APPLIED PER MANUFACTURER'S RECOMMENDATIONS. 4.ALL STEEL COMPONENTS, HARDWARE OR FASTENERS FOR WOOD FRAMING MEMBERS EXPOSED TO THE EXTERIOR, MOISTURE OR IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE HOT DIPPED GALVANIZED PER ASTM A123/A153. LIGHT GAGE CONNECTORS SHALL BE GALVANIZED PER ASTM A653, TYPE G185 MINIMUM (SUCH AS SIMPSON ZMAX STEEL OR EQUAL) OR TYPE 304 OR 316 STAINLESS STEEL. CONNECTORS FOR PRESERVATIVE TREATED WOOD USING ONLY SBX/DOT ZINC BORATE NEED NOT BE GALVANIZED. 5.STAINLESS STEEL FASTENERS SHALL BE USED WITH STAINLESS STEEL CONNECTORS AND HOT DIPPED GALVANIZED FASTENERS PER ASTM A153 SHALL BE USED WITH GALVANIZED CONNECTORS. 6.PROVIDE FLASHING, SEALANTS AND FINISHES PER THE ARCHITECTURAL DRAWINGS TO PROTECT ALL EXTERIOR WOOD SURFACES FROM MOISTURE. WOOD FRAMING 1.ALL WOOD FRAMING DETAILS SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE IBC. 2. DO NOT NOTCH ANY STRUCTURAL WOOD MEMBERS. SEE TYPICAL DETAILS FOR ALLOWABLE HOLE SIZES AND LOCATIONS FOR UTILITY PASSAGES. WALL FRAMING 1.ALL BEARING AND EXTERIOR STUD WALLS SHALL BE A MINIMUM OF 2x6 @ 16” OC, UON. WALL TYPE CALLOUTS SHOWN ON THE PLAN SHALL APPLY TO THE ENTIRE WALL LINE AT WHICH THE CALLOUT OCCURS. PROVIDE TWO STUDS MINIMUM AT THE ENDS OF ALL WALLS. 2.ALL EXTERIOR WALLS SHALL BE CLAD WITH WOOD SHEATHING AND NAILED PER MINIMUM REQUIREMENTS, UON. 3.INSTALL SOLID BLOCKING FOR ALL WOOD COLUMNS AND POSTS THROUGH FLOOR SPACES TO SUPPORTS BELOW. 4.INSTALL SHEATHING, GYPSUM WALL BOARD OR BOTH ON EACH SIDE OF ALL BEARING WALLS TO BRACE STUDS AGAINST BUCKLING. 5.PROVIDE CONTINUOUS SOLID BLOCKING AT MID-HEIGHT OF ALL LOAD BEARING WALLS OVER 12'-0” IN HEIGHT. 6.ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS AT 16” OC STAGGERED, OR BOLTED TO CONCRETE WITH 5/8” DIAMETER ANCHOR BOLTS @ 4'-0” OC (EMBED 7”), UON. 3” x 3” x .229” PLATE WASHERS SHALL BE USED WITH ALL SILL PLATE ANCHOR BOLTS. PROVIDE A MINIMUM OF TWO ANCHORS PER SILL PLATE PIECE WITH ONE ANCHOR PLACED AT 6” FROM EACH END. 7.WHERE MULTIPLE 2x STUDS ARE USED TO CREATE BUILT-UP POSTS OR BLOCKING EACH ADDED PLY SHALL BE SISTERED TO THE PREVIOUS PLY WITH FACE NAILS. AT SHEAR WALL END POSTS AND BLOCKING NAILS SHALL BE 10d AT THE EDGE NAIL SPACING SHOWN IN THE SHEAR WALL SCHEDULE. AT ALL OTHER LOCATIONS SISTERING NAILS SHALL BE 10d AT 12" OC. SISTERING NAILS SHALL BE STAGGERED IN ALL INSTANCES. 8.PROVIDE "AC" OR "BC" POST CAPS AT ALL POST TO BEAM CONNECTIONS, UON. AT POST TO CONCRETE CONNECTIONS PROVIDE "ABU" OF "CBSQ" POST BASES, UON. POSTS IN WALLS MAY BEAR ON THE SILL PLATE. FLOOR AND ROOF FRAMING 1.INSTALL DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE JOIST LENGTH AND AROUND ALL OPENINGS IN THE FLOORS AND ROOF. 2. AT BEARING SUPPORTS BEAR JOISTS AND RAFTERS 2" MINIMUM ON PLATES AND BEAMS, UON. BEAR BEAMS FULL LENGTH AND WIDTH ON SUPPORTING WALL PLATES AND POSTS, UON. 3.ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH SIMPSON "HU" SERIES JOIST HANGERS, UON. 4.INSTALL SOLID BLOCKING AT ALL BEARING POINTS. 5.TOENAIL JOISTS TO SUPPORTS WITH THREE 10d NAILS EACH END. 6.TOENAIL BLOCKING TO SUPPORTS WITH THREE 10d NAILS EACH END. 7.NAIL ALL BUILT-UP BEAMS/HEADERS TOGETHER WITH 10d @ 12” OC STAGGERED. 8. PLACE CANTS OR CRICKETS OVER CONTINUOUS ROOF SHEATHING WITH DRILLED VENT HOLES PER THE ARCHITECTURAL DRAWINGS. ROOF, FLOOR, AND WALL SHEATHING 1.ALL SHEATHING SHALL BE APA RATED, EXTERIOR EXPOSURE 1 CDX PLYWOOD OR OSB IN CONFORMANCE WITH IBC SECTION 2303.1.5. SEE DRAWINGS FOR THICKNESS, SPAN RATING, AND NAILING REQUIREMENTS. 2.SHEATHING SHALL BE MANUFACTURED UNDER THE PROVISIONS OF VOLUNTARY PRODUCT STANDARDS PS 1-09, PS 2-10, OR APA PRP-108 PERFORMANCE STANDARDS AND POLICIES FOR STRUCTURAL USE PANELS. 3.PLACE ROOF AND FLOOR SHEATHING WITH FACE GRAIN ORIENTED IN THE DIRECTION OF THE SPAN. OFFSET ADJACENT ROWS OF SHEATHING PANELS BY 24" MINIMUM, WITH ALL PANEL EDGES BEARING ON SUPPORTS. ADJUST ALL SHEATHING LAYOUTS SUCH THAT NO PANEL IS LESS THAN 16" LONG. 4.INSTALL APPROVED PANEL EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED TONGUE-AND-GROOVE JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8” SPACING AT ALL PANEL EDGES AND ENDS OF FLOOR AND ROOF SHEATHING. 5.AT BLOCKED FLOOR AND ROOF DIAPHRAGMS, INSTALL FLAT 2x BLOCKING AT ALL UNFRAMED PANEL EDGES AND NAIL WITH SPECIFIED EDGE NAILING PER PLAN. 6.GLUE FLOOR SHEATHING TO ALL SUPPORTING MEMBERS WITH ADHESIVE CONFORMING TO APA SPECIFICATION AFG-01 OR ASTM D3498. NAILING 1.MINIMUM NAILING SHALL CONFORM TO IBC TABLE 2304.10.1 OR ICC-ES REPORT NO. ESR-1539. WHERE NAILING OCCURS IN TWO OR MORE ROWS, THE ON-CENTER SPACING INDICATED ON THE DRAWINGS SHALL BE FOR EACH ROW. 2.ALL NAILS SHALL BE COMMON WIRE NAILS, UON. PROVIDE MINIMUM NAIL DIAMETERS AND LENGTHS PER THE SCHEDULE BELOW: NAIL SIZE DIAMETER x LENGTH A. SHEATHING NAILS 8d 0.131" x 2-1/4" 10d 0.148" x 2-1/2" B. FRAMING NAILS 10d 0.148" x 3" 16d 0.162" x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u n e 2 7 , 2 0 2 2 : P L O T D A T E : 7/ 1 / 2 2 7/1/2022 www.coffman.com ph 360.707.5656 135 W Fairhaven Ave., Suite 102 Burlington, WA 98233 BJW RLR STRUCTURAL NOTES 2 S0.2 1 FOUNDATION-FIRST FLOOR PLAN 1/4"=1'-0" REV DATE DESCRIPTION PROJ. NO. DRAWN CHECKED DATE SHEET OF COFFMAN ENGINEERS INC.C 221651 11/03/2022 SHEET TITLE: SHEET NO: 1 A B C D A B C D 1 2 3 4 5 2 3 4 5 BINGHAM ADDITION 1711 69TH PL W, EDMONDS, WA 98026 PERMIT SET 6P: \ S E A \ 2 2 J O B S \ 2 2 1 6 5 1 B I N G H A M R E S I D E N C E \ 0 . 0 D W G S \ S \ 2 2 1 6 5 1 S _ S 2 . 1 . D W G .S2 . 1 : NE Y , B R E N N A N : L A S T S A V E D : De c e m b e r 8 , 2 0 2 2 : P L O T D A T E : 12 / 8 / 2 2 12/8/2022 www.coffman.com ph 360.707.5656 135 W Fairhaven Ave., Suite 102 Burlington, WA 98233 BJW RLR FOUNDATION-FIRST FLOOR PLAN 3 S2.1 PLAN NOTES: 1. VERIFY ALL DIMENSIONS WITH ARCHITECT. SEE ARCHITECTURAL DRAWINGS FOR CONCRETE AND WOOD WALL LOCATIONS. FOOTINGS ARE CENTERED ON CONCRETE WALLS, UON. 2. BOTTOM OF ALL FOOTINGS SHOWN IN THIS PLAN SHALL BE AT LEAST 18 INCHES BELOW GRADE, UON. CONTRACTOR SHALL COORDINATE WITH FINAL SITE GRADES AND MAINTAIN MINIMUM FOOTING DEPTHS SHOWN ON THE DRAWINGS. 3. POSTS OR JAMB STUDS SUPPORTING BEAMS ABOVE SHALL BE (2) STUDS, UON. POSTS/STUDS SHALL BE CONTINUOUS TO CONCRETE FOUNDATION. MULTI-STUD POSTS SHALL BE NAILED TOGETHER PER THE GENERAL STRUCTURAL NOTES. 4. ALL FRAMING SHALL HAVE CONTINUOUS DOUBLE TOP PLATE THAT IS SPLICED PER 8/S5.1 WHERE REQUIRED. 5. STUD WALLS SHALL BE PER ARCHITECTURAL WALL ASSEMBLIES AND AS FOLLOWS, UON: EXTERIOR WALLS: 2x6 @ 24" OC INTERIOR PARTITION WALLS: 2x4 @ 24" OC SEE 1, 2 & 3/S5.1 FOR ALLOWABLE HOLES & NOTCHES IN STUD AND PLATES. 6. SHEAR WALL TYPE AND EXTENTS ARE AS SHOWN ON PLAN (SEE LEGEND). CONTRACTOR SHALL INSTALL PLYWOOD PER 19/S5.1 ON SIDE OF WALL INDICATED BY MARK ON PLAN, UON. 7.PROVIDE SHEATHING ON ALL EXTERIOR WALL SURFACES (EVEN THOUGH THOSE NOT INDICATED AS SHEAR WALLS). SHEATHING SHALL BE 7/16" PLYWOOD OR OSB W/ 8d NAILS @ 6" OC EDGES AND 12" OC FIELD. 8. FLOOR SYSTEM SHALL CONSIST OF 23/32" T&G SHEATHING (PANEL SPAN RATING 48/24). NAIL SHEATHING WITH 8d NAILS @ 6" OC (EDGES) AND 12" OC (FIELD). GLUE SHEATHING AT ALL SUPPORTS AND GLUE JOISTS TO SADDLES OF ALL HANGERS WITH ADHESIVE CONFORMING TO APA SPECIFICATION AFG-01. 9. FLOOR JOISTS SHALL BE 9 1/2" TJI 110 @ 16" OC, UON. WHERE REQUIRED, PROVIDE IUS OR MIU HANGERS TO MATCH JOIST SIZE AT ALL FLUSH WOOD JOIST-TO-WOOD BEAM OR WOOD JOIST-TO-RIM JOIST HEADER CONNECTIONS. 10. PROVIDE 1 1/4"x9 1/2" LSL RIM JOIST, TYP UON. 11. ALIGN HOLDOWN WITH POST SUPPORTING GIRDER TRUSS ABOVE. LEGEND STRUCTURAL WALL ABOVE (SEE PLAN NOTE 5) POST ABOVE (SEE PLAN NOTE 3) HOLDOWN TYPE, SEE 18/S5.1 X LINEAR FEET OF TYPE Y SHEAR WALL, SEE 19/S5.1 Fx FOOTING PER SCHEDULE, SEE 18/S5.2 HDUx Y X FLOOR SHEATHING PER PLAN NOTE 8 2x10 HF #2 @ 16" OC MIN 15/S5.2 20/S5.2 19/S5.2 6 40'-6" 64'-6" 3 1 / 2 " x 5 1 / 2 " 1 . 3 E L S L P O S T W / A 3 4 T O ( E ) S I L L P L A T E , T Y P VERIFY NAIL SPACING FOR ENTIRE LENGTH OF WALL AND INCREASE NAILING, IF REQUIRED, PER THE SHEARWALL SCHEDULE. (E ) F L O O R J O I S T @ 1 6 " O C , T Y P (E) WOOD WALL TO BE REMOVED (E) WOOD WALL, TYP F2.5 CONT POST TO NEW FOOTING BELOW 1 ROOF PLAN 1/4"=1'-0" REV DATE DESCRIPTION PROJ. NO. DRAWN CHECKED DATE SHEET OF COFFMAN ENGINEERS INC.C 221651 11/03/2022 SHEET TITLE: SHEET NO: 1 A B C D A B C D 1 2 3 4 5 2 3 4 5 BINGHAM ADDITION 1711 69TH PL W, EDMONDS, WA 98026 PERMIT SET 6P: \ S E A \ 2 2 J O B S \ 2 2 1 6 5 1 B I N G H A M R E S I D E N C E \ 0 . 0 D W G S \ S \ 2 2 1 6 5 1 S _ S 2 . 2 . D W G .S2 . 3 : NE Y , B R E N N A N : L A S T S A V E D : No v e m b e r 2 1 , 2 0 2 2 : P L O T D A T E : 11 / 2 9 / 2 2 11/29/2022 www.coffman.com ph 360.707.5656 135 W Fairhaven Ave., Suite 102 Burlington, WA 98233 BJW RLR ROOF PLAN 4 S2.2 PLAN NOTES: 1. VERIFY ALL DIMENSIONS WITH ARCHITECT. 2. ROOF SHEATHING SHALL BE 15/32" T&G SHEATHING (PANEL SPAN RATING 32/16). NAIL SHEATHING WITH 8d NAILS @ 4" OC EDGES AND 12" OC FIELD. 3.ROOF FRAMING SHALL BE 2x6 @ 24" OC MIN. 4.VERIFY EXISTING FLOOR AND ROOF FRAMING ABOVE AND SHORE EXISTING STRUCTURE AS REQUIRED TO INSTALL NEW BEAM. LEGEND SPAN DIRECTION OF FRAMING MEMBERS STRUCTURAL WALL BELOW POST BELOW HEADER PER 5/S5.1 BL W Hx BEAM / HEADER SCHEDULE MARK TYPE H1 4x6 HF #2 W/ (1) TRIM STUD & (1) KING STUD EA SIDE (KING AND TRIM STUD NOT REQ'D AT HANGER) H2 3 1 2" x 9" 24F-V4 GLULAM W/ (2) TRIM STUDS & (1) KING STUD EA SIDE B = BEAM H = HEADER, SEE 5/S5.1 ROOF SHEATHING PER NOTE 2 2X6 ROOF JOIST @ 24" OC, MIN ROOF OUTLINE 9/S5.2 10/S5.2 5/S5.2 H1 H2 H1 13/S5.2 SISTER (N) 2x12 HF #2 JOIST TO EXISTING JOISTS W/ 10d @ 16" OC STAGGERED. ALTERNATIVELY W1 0 x 2 6 (2) 1-3/4" x 11-1/4" 2.0E LVL, SEE NOTE 4 (E ) F L O O R J O I S T @ 1 6 " O C , T Y P (E) WOOD WALL, TYP 14/S5.2 12/S5.2 TLOK04 EA SIDE OF STEEL BEAM THRU FLANGE TO DBL TOP PLATE AND HEADER. (E) WOOD WALL BELOW TO BE REMOVED HUC46 HANGER HUC46 HANGER RECTANGULAR OR ROUND OPENING 6 OPENING IN CONCRETE SLAB ON GRADE NTS 2" 2'-0" TYP 6'-0" MAX 6' - 0 " M A X (1) #4 CTR OF SLAB, TYP (1) #4 DIAG CTR OF SLAB 2'-0" 2' - 0 " NOTE: USE EXPANSION JOINT WHERE VERTICAL MOVEMENT IS NOT OF CONCERN. 1 2" EJ PRE-MFR JOINT W/ REINF THROUGH CONTRACTION JOINT CONSTRUCTION JOINT EXPANSION JOINT EXISTING GRADE PREPARED BY OTHERS SAWCUT OR USE 1 8" PREMOLDED JOINT REINF THROUGH 6" GRAVEL, MIN. CLASSIFIED AS GW OR GP PER UNITED SOIL CLASSIFICATION SYSTEM, TYP VAPOR BARRIER, 15 MIL MIN, COMPLY W/ ASTM E-1745, TYP TOOLED JOINT AT EXPOSED AREAS D/ 3 D SLAB ON GRADE, SEE PLAN FOR REINF, TYP 7 SLAB ON GRADE JOINT DETAILS 1"=1'-0" NOTES: 1. FOR ITEMS NOT NOTED SEE PLAN & SHEAR WALL SCHED. 2. MINIMUM PANEL DIMENSION IS 2'-0". 3. USE FULL SIZE PANELS WHERE POSSIBLE. EDGE NAILING AT JOINT (STAGGER) HOLDOWN ANCHOR PER PLAN EDGE NAILING PER SCHED HOLDOWN POST PER HOLDOWN SCHED TOP PLATES FIELD NAILING EDGE NAILING AT PLATE (STAGGER) 1 2" MIN EDGE DISTANCE, TYP STUD PER PLAN DOUBLE STUDS AT PLYWOOD JOINTS WHERE EDGE NAIL SPACING IS 3" OR LESS (NAIL TOGETHER W/ 10d NAILS AT SHEAR WALL EDGE NAIL SPACING) 14 TYP SHEAR WALL ELEVATION NTS 16 STEPPED FOOTING 1/2"=1'-0" T HT 3' - 0 " M A X EQUAL T 1'-0" MIN 1.5xHT 2'-0" MIN MATCH FOOTING REINF IF PIPE FALLS IN THESE LOCATIONS CONT PIPE, TYP BACKFILL AND COMPACT TRENCH SEE SOILS REPORT NOTE: REBAR NOT SHOWN PIPE SLEEVE CONT PIPE WRAPPED WITH 1-1/2" COMPRESSIBLE MATERIAL AT SLEEVE LEAN CONCRETE 2000 PSI MIN NO PIPE THIS AREA STEP FOOTING & SLEEVE PIPE THRU WALL SLEEVE PIPE & CAST FOOTING TO BOTTOM OF TRENCH 1 1.5 UTILITY/PIPE TRENCH PARALLEL TO FOOTING FOR FOOTING/GRADE BEAM THICKNESS AND REINF SEE FOUNDATION WALL SECTIONS NOTES: 1. SINGLE PIPES 8"Ø OR LESS PERPENDICULAR TO AND GREATER THAN 24" CLEAR BELOW FOOTINGS DO NOT REQUIRE CONCRETE ENCASEMENT. (PIPE GROUPINGS BELOW 24" SHALL BE REVIEWED BY THE STRUCTURAL ENGINEER). 2.PIPES LARGER THAN 8"Ø SHALL BE REVIEWED BY THE STRUCTURAL ENGINEER. PROVIDE PIPE SLEEVE AT FOUNDATION AND WRAP THE CONT PIPE WITH 1-1/2" COMPRESSIBLE MATERIAL, TYP 9" MIN 6" MI N 6" MI N SE E N O T E 1 IF P I P E F A L L S IN T H I S L O C A T I O N T W NO VERTICAL PIPES IN THIS AREA 18" MIN SE E N O T E 1 T 6" SECTION A-A 11 PIPE CLEARANCE @ STRIP FOOTING/GRADE BEAM 1/2"=1'-0" HORIZ BARS HORIZ BARS VERT BARS (2) #5 MIN CORNER BARS SAME SIZE & SPCG AS HORIZ BARS DOUBLE MAT REINFORCING NOTE: ALL LAP SPLICES CLASS B TENSION SINGLE MAT REINFORCING LAP SPLICE 17 CORNER REINFORCING 1/2"=1'-0" CORNER BARS SAME SIZE & SPCG AS HORIZ BARSLAP SPLICE BOLT SIZE & ANCHOR SPACING PER SCHED USE GALVANIZED NAILS PER GENERAL STRUCTURAL NOTES AT PRESSURE TREATED SILL PLATES CONNECTION OF JOIST OR BLKG TO TOP PLATE PER SCHED RIM JOIST OR BLKGSEE FRAMING DETAILS SEE FRAMING DETAILS A A BEAM PER PLAN, TOENAIL TO SUPPORTS W/ (2) 16d EA SIDE POST PER PLAN END OF STUD WALL EXTEND BEAM TO END OF POST & TOENAIL TO TOP PLATE W/ (2) 16d EA SIDE POST/STUDS PER PLAN 9 TYP FLUSH BEAM SUPPORT 3/4"=1'-0" CL SPLICE AT LOWER PLATE CL SPLICE AT UPPER PLATE PROVIDE STUD BELOW EA SPLICE ELEVATION 6'-0" MIN BETWEEN SPLICES 16d @ 12" OC, STAGGERED ELSEWHERE (8) 16d @ 4" OC STAGGERED @ EA SPLICE 8 TOP PLATE SPLICE NTS SINGLE STUD DOUBLE STUD 11 2"Ø MAX HOLE 3 4" MIN CLR EA SIDE 21 4"Ø MAX HOLE 112" MIN CLR EA SIDE 2x62x4 2x6 (3x6 SIMILAR) 2x4 (3x4 SIMILAR) 218"Ø MAX HOLE 5 8" MIN CLR EA SIDE 314"Ø MAX HOLE 1" MIN CLR EA SIDE 3 4"MAX 11 4"MAX 6" MA X 8" MA X NOTES: 1.NOTCHES SHALL NOT BE ALLOWED IN MORE THAN (2) CONSECUTIVE STUDS IN BEARING WALLS. 2.CONTACT ENGINEER FOR DIRECTION IF MORE NOTCHES ARE NEEDED. 21 4"Ø MAX HOLE 11 2"Ø MAX HOLE 112" MIN EA SIDE 3 4" MIN EA SIDE 31 4"Ø MAX HOLE 218"Ø MAX HOLE 1" MIN EA SIDE 5 8" MIN EA SIDE 2x62x4 NO REINF REQD 2x62x4 STRAP REINF NOTE: AT BOTTOM PLATES, FOLLOW GUIDELINES SHOWN EXCEPT USE CS16 x 2'-0" STRAP. NOTES: 1.NO MORE THAN (2) CONSECUTIVE STUDS MAY BE BORED IN BEARING WALLS. 2.CONTACT ENGINEER FOR DIRECTION IF MORE HOLES ARE NEEDED. 3.MULTIPLE HOLES IN STUDS SHALL BE SPACED TO PROVIDE (3) DIAMETERS CLEARANCE BETWEEN HOLES BASED ON LARGER HOLE SIZE. (NO REINF REQD) PSPN516Z STRAP 2 NOTCHES ALLOWED IN STUDS 3/4"=1'-0"3 HOLES ALLOWED THRU STUDS 3/4"=1'-0"1 HOLES ALLOWED THRU TOP PLATES 3/4"=1'-0"5 TYP HEADER FRAMING 3/4"=1'-0" TYP STUDS FULL-HEIGHT KING STUD PER PLAN TRIM STUD PER PLAN (NAIL MULTIPLE STUDS TOGETHER IN ACCORDANCE WITH GENERAL STRUCTURAL NOTES) HEADER PER PLAN, TOE-NAIL TO SUPPORTS W/ (2) 16d EA SIDE SOLID BLKG BELOW POST AS REQD TYP DBL TOP PLATE, SPLICE PER 8/S5.1 POST ABOVE, WHERE OCCURS NOTES: 1.ALLOWABLE HOLES THROUGH PRE-ENGINEERED PRODUCTS (SUCH AS I-JOISTS) SHALL BE AS PERMITTED BY MFR. 2.WHERE PROPOSED PENETRATION WOULD NOT CONFORM TO THIS DETAIL, SUBMIT TO ENGINEER FOR REVIEW (3) DAYS MIN PRIOR TO DRILLING. ANY ADDITIONAL REINFORCING REQUIRED TO ACCOMMODATE THE NON-CONFORMING PENETRATION SHALL BE PROVIDED AT NO ADDITIONAL EXPENSE TO THE OWNER. MIN DIST BTWN ANY TWO HOLES = 6" H/ 3 H/ 3 H L/4 L/4 L CL ALLOWABLE HOLE ZONE CENTER OF BEARING, TYP SOLID JOIST OR BEAM SOLID WOOD JOIST OR BEAM PER PLAN (SIM @ STL BM) - NO HOLES OUTSIDE OF ALLOWABLE HOLE ZONE MAX HOLE DIA=SMALLER OF H/5 OR 0'-6", TYP 4 TYP ALLOWABLE HOLES THROUGH WOOD MEMBERS NTS AT HOLDOWN HOLDOWN SCHEDULE STUD SIZE HDU4 HDU8 HDU5 HDU2 4" STUDS 4" STUDS 6" STUDS 6" STUDS 4" STUDS 4" STUDS 6" STUDS 6" STUDS (2) 2x4 WALL STUD SIZE; SEE PLAN ANCHOR ROD NOTES: 1. SEE PLAN FOR HOLDOWN TYPES AND LOCATIONS. 2. SEE PLAN FOR TYPICAL STUD SIZES IN SHEAR WALLS. 3. NAIL BUILT-UP POSTS TOGETHER W/ 10d NAIL STAGGERED AT SAME SPACING AS SHEAR WALL EDGE NAILING. TYPE 18 HOLDOWN SCHEDULE NTS SB5 8x24 SB5 8x24 (2) 2x6 (2) 2x4 (2) 2x6 (3) 2x4 (2) 2x6 (4) 2x4 (3) 2x6 SB5 8x24 SB7 8x24 LTT19 4" STUDS 6" STUDS (2) 2x4 (1) 2x6 SB5 8x24 NOTES: 1.SEE PLANS FOR SHEAR WALL TYPE, LOCATIONS, AND HOLDOWNS. 2.REFER TO DETAIL 14/S5.1 FOR TYPICAL SHEAR WALL ELEVATION. 3.SHEATHING SHALL BE PLACED ON THE SIDE OF THE WALL WHERE THE SYMBOL OCCURS ON THE PLAN. 4.ALL INFORMATION IN THE SCHEDULE RELATES TO THE ITEMS SHOWN IN FRAMING DETAILS. ALL COMPONENTS FOR EACH SHEAR WALL TYPE OCCUR IN THE WALLS BETWEEN THE LEVEL REPRESENTED BY THE FRAMING PLAN, WHERE THE SHEAR WALL TYPES AND LOCATIONS ARE SHOWN, AND THE LEVEL ABOVE. 5.AT CONCRETE FOOTINGS, USE 5 8" DIAMETER SILL PLATE BOLTS WITH MINIMUM 7" EMBEDMENT INTO THE CONCRETE. REFER TO THE SCHEDULE FOR BOLT SPACING. 6.BLOCK ALL UNSUPPORTED SHEATHING EDGES WITH MINIMUM 2x LAID FLAT BEHIND EDGES OF SHEATHING. 7.SEE GENERAL NOTES FOR SHEATHING GRADES AND SPECIFICATIONS. SHEATHING SHALL HAVE A MINIMUM SPAN RATING OF 24/0. 8.SEE GENERAL NOTES FOR MINIMUM NAIL DIAMETERS AND LENGTHS. 9.FOR SW2 AND SW3 TYPE SHEAR WALLS, ALL FRAMING MEMBERS RECEIVING EDGE NAILING FROM ABUTTING PANELS SHALL NOT BE LESS THAN 3" NOMINAL MEMBERS AND NAILS SHALL BE STAGGERED. DOUBLE 2x MEMBERS MAY BE SUBSTITUTED FOR THE 3x MEMBER, MEMBERS SHALL BE NAILED TOGETHER PER THE ATTACHMENT FOR THE BOTTOM PLATE NAILING. 10.SEE GENERAL STRUCTURAL NOTES FOR PLATE WASHER MINIMUM SIZE. BOTTOM PLATE WASHERS SHALL BE LOCATED SUCH THAT THE EDGE OF THE WASHER IS WITHIN 12" OF THE BOTTOM PLATE ON THE SIDE WITH THE SHEATHING. 19 SHEAR WALL SCHEDULE NTS Y 13 WALL CORNER DETAIL 3/4"=1'-0" WALL SHEATHING, SEE DETAILS WALL STUDS PER PLAN EDGE NAILING BACKING FOR GYPSUM BOARD HOLDOWN PER PLAN HOLDOWN POST, SEE SCHED 2x6 (3x6 SIMILAR) 2x4 (3x4 SIMILAR) PSPN516Z STRAP 3"Ø MAX HOLE 2" MIN EA SIDE 41 2"Ø MAX HOLE 11 4" MIN EA SIDE 2x8 2x8 PSPN516Z STRAP 13 4"MAX 8" MA X 2x8 (3x8 SIMILAR) 3"Ø MAX 2" MIN CLR EA SIDE 2x8 2x8 (3x8 SIMILAR) 412"Ø MAX 11 4" MIN CLR EA SIDE HOLE HOLE CCQ COLUMN CAP SIZE AS REQD TO FIT POST & BEAM, UON, ROTATE STRAPS AS REQD TO AVOID DRYWALL ECCQ COLUMN CAP, UON POST PER PLAN BEAM PER PLAN. BEAM CONT OVER POST WHERE SHOWN ON PLAN 1 2" CLR WHERE BEAM IS NOT CONTINUOUS 10 BEAM TO POST CONNECTION 3/4"=1'-0" SHEAR WALL SCHEDULE EDGE NAILS FIELD NAILSSTUD SIZETYPE 1 2 3 SOLE PLATE NAILING 4 SILL PLATE BOLTS 5 16d @ 21 2" OC 5 8"Ø BOLTS @ 16" OC 7 16"2 3 4 6 2x STUDS PER PLAN 8d @ 2" OC RIM JOIST SCREWS TIMBERLOK TLOK06 @ 6" OC TIMBERLOK TLOK06 @ 7" OC TIMBERLOK TLOK06 @ 10" OC TIMBERLOK TLOK06 @ 15" OC 16d @ 3" OC 16d @ 4" OC 16d @ 6" OC 5 8"Ø BOLTS @ 24" OC 5 8"Ø BOLTS @ 32" OC 5 8"Ø BOLTS @ 48" OC 2x STUDS PER PLAN 2x STUDS PER PLAN 2x STUDS PER PLAN 8d @ 12" OC 8d @ 3" OC 8d @ 12" OC 8d @ 4" OC 8d @ 12" OC 8d @ 6" OC 8d @ 12" OC PLYWOOD OR OSB SHEATHING 7 16" 7 16" 7 16" REV DATE DESCRIPTION PROJ. NO. DRAWN CHECKED DATE SHEET OF COFFMAN ENGINEERS INC.C 221651 07/01/2022 SHEET TITLE: SHEET NO: 1 A B C D A B C D 1 2 3 4 5 2 3 4 5 BINGHAM ADDITION 1711 69TH PL W, EDMONDS, WA 98026 PERMIT SET 6P: \ S E A \ 2 2 J O B S \ 2 2 1 6 5 1 B I N G H A M R E S I D E N C E \ 0 . 0 D W G S \ S \ 2 2 1 6 5 1 S _ S 5 . 1 . D W G .S5 . 1 : NE Y , B R E N N A N : L A S T S A V E D : Ju n e 2 7 , 2 0 2 2 : P L O T D A T E : 7/ 1 / 2 2 7/1/2022 www.coffman.com ph 360.707.5656 135 W Fairhaven Ave., Suite 102 Burlington, WA 98233 BJW RLR TYPICAL SECTIONS AND DETAILS 5 S5.1 JOISTS PER PLAN W10x26 BEAM BEAM PER PLAN PROVIDE STAGGERED TLOK04 @ 2'-0" OC (2) ROWS OF 1/2" Ø BOLTS, CNTR ON BEAM WOOD FILLER TO MATCH FLANGE WIDTH, CNTR ON BEAM (12" WIDTH MIN), TYP 2X CONT NAILER TO MATCH JOIST HEIGHT, RIP AS REQ'D (E) STUD WALL 13 WOOD BEAM TO STEEL BEAM 1"=1'-0" 3" 51 2" HHUS410 HANGER 4" MI N 6" MI N 5"5" 3" CL R 8" 6" JOIST PER PLAN #4x @ 24", ALT HOOKS NOTE: SEE 19/S5.1 FOR SHEAR WALL SCHEDULE & HARDWARE. STUD WALL PER PLAN (2) #4 CONT BOT (2) #4 CONT#4 @ 12" HORIZ 2x PT SILL PLATE FLUSH W/ INSIDE FACE OF STEM WALL 4 1 2 20 FOOTING AT EXTERIOR WALL 1/2"=1'-0" 5 19 FOOTING AT EXTERIOR WALL 1/2"=1'-0" 2x PT SILL PLATE FLUSH W/ INSIDE FACE OF STEM WALL STUD WALL PER PLAN 10d @ 4" OC TO BLKG JOIST PER PLAN LSL BLKG @ 48" OC, TYP NOTES: 1.SEE 19/S5.1 FOR SHEAR WALL SCHEDULE & HARDWARE. 2.SEE 20/S5.2 FOR INFO NOT SHOWN. 4 1 2 6" MI N 11 4" LSL RIM JOIST 11 4" LSL RIM JOIST FOOTING REINFORCING SCHEDULE TYPE SIZE (WxLxD)BOTTOM REINFORCING MAX ALLOWABLE LOAD (KIPS) F1 1'-0"x1'-0"x0'-6"(2) #4 EA WAY 1.4 F1.33 1'-4"x1'-4"x0'-6"(2) #4 EA WAY 2.5 F1.5 1'-6"x1'-6"x0'-6"(2) #4 EA WAY 3.2 F1.67 1'-8"x1'-8"x0'-6"(2) #4 EA WAY 4.0 F2 2'-0"x2'-0"x0'-8"(2) #4 EA WAY 5.7 F2.5 2'-6"x2'-6"x0'-8"(3) #4 EA WAY 8.8 F3 3'-0"x3'-0"x0'-8"(3) #4 EA WAY 12.6 18 FOOTING SCHEDULE NTS (E) FLOOR 15 FOOTING AT EXTERIOR WALL 1/2"=1'-0" FLOOR LEVEL FLOOR JOIST PER PLAN HANGER PER PLAN 2x CONT LEDGER W/ (3) TLOK04 SCREWS @ 12" OC STAGGERED EDGE NAILING (E) WALL TO BE REMOVED 9 ROOF LEDGER DETAIL 3/4"=1'-0" (E) STUD WALL PER PLAN (E) WALL SHEATHING 2x10 CONT LEDGER W/ (2) TIMBERLOK TLOK06 @ 6" OC AT EA STUD ROOF SHEATHING PER PLAN ROOF JOISTS PER PLAN W/ (3) 10d TOENAIL TO LEDGER 2'-0" MAX ROOF JOISTS PER PLAN 2x BLOCKING H2.5A CLIP EA JOIST STUD WALL PER PLAN 10 EAVE DETAIL 3/4"=1'-0" NOTE: SEE 19/S5.1 FOR SHEAR WALL SCHEDULE & HARDWARE. EDGE NAILING 1 2x CONT 31 2" MIN 2 OVERHANG (SLOT THROUGH SHEATHING) ROOF SHEATHING PER PLAN AIR FLOW BEAM PER PLAN 5 ROOF JOIST OUTRIGGER DETAIL 3/4"=1'-0" 2 1 2'-0" MAX2x4 OUTRIGGER @ 24" OC ROOF JOIST PER PLAN ROOF SHEATHING PER PLAN 2x4 BLKG EDGE NAILING 2x4 CONT STUD WALL PER PLAN (3) 10d EA OUTRIGGER NOTE: SEE 19/S5.1 FOR SHEAR WALL SCHEDULE & HARDWARE. TIMBERLOK TLOK06 AT EA OUTRIGGER (E)FLOOR JOIST EDGE NAILING VERIFY EXISTING FLOOR AND ROOF FRAMING ABOVE AND SHORE EXISTING STRUCTURE AS REQUIRED TO INSTALL NEW BEAM LUS28 HANGER AT EACH JOIST, TYP (E) FLOOR JOISTS 2 1 STUD WALL PER PLAN (E) WALL ABOVE (E) FLOOR SHEATHING 14 FLOOR JOISTS PERPENDICULAR 3/4"=1'-0" FLOOR LEVEL NOTE: SEE 19/S5.1 FOR SHEAR WALL SCHEDULE & HARDWARE. 11 4" LSL RIM JOIST CONT TOP PLATE, SPLICE PER 8/S5.1 3 12 STEEL BEAM TO WOOD POST 3/4"=1'-0" POST PER PLAN (MIN. WIDTH SHALL MATCH BEAM WIDTH) STEEL BM PER PLAN PL18"x3"x0'-7" W/ (2) ROWS OF (3) 16d EA SIDE 3/16 16d @ 6" OC REV DATE DESCRIPTION PROJ. NO. DRAWN CHECKED DATE SHEET OF COFFMAN ENGINEERS INC.C 221651 11/03/2022 SHEET TITLE: SHEET NO: 1 A B C D A B C D 1 2 3 4 5 2 3 4 5 BINGHAM ADDITION 1711 69TH PL W, EDMONDS, WA 98026 PERMIT SET 6P: \ S E A \ 2 2 J O B S \ 2 2 1 6 5 1 B I N G H A M R E S I D E N C E \ 0 . 0 D W G S \ S \ 2 2 1 6 5 1 S _ S 5 . 2 . D W G .S5 . 2 : NE Y , B R E N N A N : L A S T S A V E D : De c e m b e r 8 , 2 0 2 2 : P L O T D A T E : 12 / 8 / 2 2 12/8/2022 www.coffman.com ph 360.707.5656 135 W Fairhaven Ave., Suite 102 Burlington, WA 98233 BJW RLR WOOD FRAMING SECTIONS AND DETAILS 6 S5.2