Loading...
APPROVED ENG PLN RESUB 1+Site_Plan+12.14.2022_9.44.47_AM+3268219SITE PLAN OWNERS: SCOTT & KARYNN BINGHAM ADDRESS: 17116 69TH PL W, EDMONDS, WA 98026 PARCEL NUMBER: 01017300000500 LEGAL DESCRIPTION: Section 08 Township 27 Range 04 Quarter NW STEINMAN'S MEADOWDALE ESTATES BLK 000 D-00 LOT 5 TGW EQ & UND INT IN COMM AREAS SCALE: 1" = 20' 0 20' 40' TOTAL STRUCTURAL LOT COVERAGE SFR FOOTPRINT LIVING SPACE (EXIST'G) 1,530 SF GARAGE COVE( ES (EXIST'G) 557 REDPORCHSF PROPOSED ADDITIONAL LIVING SPACE 61 SF TOTAL STRUCTURAL COVERAGE 2,994 SF LOT AREA PERCENTAGE OF COVERAGE 12,216 SF 24.5% TOTAL IMPERVIOUS SURFACES 3,183 SF EXISTING SFR W/OVERHANGS 1.200 SF DRIVE, WALKS,PATIOS 4,383 SF TOTAL EXISTING PROPOSED ADDITION 61 SF TOTAL PROPOSED IMPERVIOUS SURFACE 4,444 SF PERCENTAGE OF IMPERVIOUS SURFACES 36.4% DATUM POINT E 385.10' NW CORNER A 387.0' NE CORNER B 386.0' SE CORNER C 386.0' SW CORNER D 387.0' TOTAL 1,546.0' AVG. GRADE 386.5' (154674) ACTUAL = 411' (386' + 25' MAX. ALLOWABLE = 411. ' (386.5' + 25) MAX HEIGHT OF EXIST'G = 410.9' HEIGHT OF PROP. ADD'N = 400.5' OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE 100, OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING / ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. / a d 4" TIGHTLINE •$ a� TO STC(RM SEWER ti TIO EXIST'G C386.0'i�\ SILT FENCE s \07 t � � 4 6" TIGHTLINE B `' ; \ SOIL STORAGE TO STORM SEWER — — — , \ \ OVER W/IN PR OPOSED STORM SEWER STUB \� MANHOLE \ COVER (SEWER) BEN MARK E 385.15' SIDE WALK FILTER SOCKS SHALL BE ADDED TO ANY CATCH BASINS DOWNSTREAM FROM AD THE CONSTRUCTION SITE. @385 SEE CITY STANDARD DETAIL ER-902. Zone RS-20 Corner ' _ _ _ _ : Flag Setbacks: Required Actual Front 25' 25' 10 1-- Sides 20' 20' Rear Meadowdale EatatesPRD 25 14' Height radr obw SUBJ. PROP. BOUNDARY LINES BUILDING SETBACK REQ'D SANITARY SEWER LINE TIGHTINES - STORM ®� PROPOSED ADDITION FOOTPRINT -� EXISTING SFR FOOTPRINT ROOFLINE -� EXISTING CONCRETE DRIVEWAY EXISTING GRAVEL SURFACE ELEVATION CONTOURS (5) SILT FENCE = 61 SF ADDITION " PROPOSED \ \ °'��I \ 61 SF ADDITION �v ' EXIST'ING CON SFR,,=� - �; �PATIOREXI TING ' 1,530 SF \, �A z ' INSTALL & MAINTAIN ALL SANITARY TESC MEASURES ACCORDING TO APPROVED PLANS, CITY \ SMER �\ ,, = o I OF EDMONDS STANDARD GARAGED387.0' DETAILS, & ALL OTHER ,84$ SF- „� z MEASURES THAT MAY BE REQUIRED DURING CONSTRUCTION WATER METER \' � `' -- Y r7j ° ALL DISTURBED AREAS TO BE 387.000NCRE1E DRIVWAY COMPOST AMENDED PER EXISTING zp e_ a a ° 2014 SWMMWW BMP T.5.13 \ a a• °'a a aSetR CATCH BASIN N ��.¢94 Q �� ENGINEERING DIVISION 17.0328"F APPROVED AS NOTED 01 /05/2023 APPROVED BY PLAN ING Applicant shall repair damage to utilities or improvements in City ri Dec 2¢ $Q22 per city standards that is occurs during the permi ly_ 088,Y681 RESUB Dec 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT